HomeMy WebLinkAboutREVISION RESPONSES - 18-00269 - T-Mobile - Tenant Finish 1 | Page Gary Wang & Associates, Inc. Member of American Institute of Architects 1000 Corporate Center Drive Suite 550 Monterey Park, CA 91754 Tel: (626) 288-6898 Fax: (626) 768-7101 June 18, 2018 Attn: Quinton Owens City of Rexburg Community Development Department 35 North 1st East. Rexburg, ID 83440 P: 208.372.2341 208.372.2344 Re: CFT development (T-mobile) 1480 N. 2nd E., STE. 130 Rexburg, ID 83440 Plan Check #: 18-00269 Please see responses below to the Building Code Plan review comments. All revisions are clouded with  2 on the sheets indicated below. 1. Not identified on plans, Default is Mercantile (M) for the display and sale of merchandise and involves stocks of goods. Occupancy type needs to be identified on plans.  Response: Please see sheet G-001 on the Building Code Analysis for the updated occupancy classification. 2. Fireblocking will be approved based on inspection.  Response: Note has been added. Please see G-004 on the Building Department Notes. 3. Did not find occupant load on plans. Default occupant load per IBC 1004 is 100 gross sf per occupant. That makes the occupant load 15 unless otherwise submitted and approved.  Response: Please see sheet G-001 for Occupant Load Calculation table. 4. At least 36” of service counter no more than 36” above floor shall be provided for accessibility. Furnishings are not shown on plans.  Response: Please see sheet A-106 Furniture Plan for the counter dimension + Location