HomeMy WebLinkAboutRESCHECK - 18-00293 - 1236 Bond Ave - Tooth TimeREScheck Software Version 4,6.5 Compliance Certificate Project Tooth Time Energy Code: 2015 IECC Location: Rexburg, Idaho Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 4,252 ft2 Glazing Area 25%u Climate Zone: 6 (8693 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: 1236 Bond Ave Designer/Contractor: Rexburg, ID 83440 tared Kay J. B. Kay Construction, LLC 950 Vista Ave Rexburg, 1D 83440 208-716-2374 jared@jbkayconstruction.com Compliance: 38.9% Better Than Code Maximum UA: 612 Your UA: 374 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies 4,t5t 50.0 48.0 0.011 47 Wall 1: Wood Frame, 16" o.c. 2,520 22.0 22.0 0.024 45 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low -E 550 0.290 160 Door 1: Glass 84 0.290 24 Basement Wall 1: Solid Concrete or Masonry Wall height: 9.0' 4,252 19.0 19.0 0.023 98 Depth below grade: 9.0 - Insulation depth: 9.0' Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature r)ate Project Title: Tooth Time Report date: 05/31/18 Data filename: Untitled.rck Page 1 of 9 REScheck Software Version 4.6.5 Inspection Checklist Energy Code: 2015 IECC Requirements: 39.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # & Req.lb Pre-inspection/Plan Review Plans Verified Field Verified Value Value Complies? Comments/Assumptions 103.1, Construction drawings and 103.2 [PR1]1 documentation demonstrate energy code compliance for the ❑Complies Requirement will be met. ❑Does Not building envelope. Thermal envelope represented on ❑Not Observable construction documents. ❑Not Applicable 103.1, Construction drawings and 103.2, documentation demonstrate ❑Complies 403.7 [PR3]1 energy code compliance for ❑Does Not lighting and mechanical systems. Systems serving multiple ❑Not Observable dwelling units must demonstrate ❑Not Applicable compliance with the IECC Commercial Provisions, 302.1, 403.7 Heating and cooling equipment is sized per ACCA Manual S based Heating: Heatin g' ❑Complies [PR2]2 on loads calculated per ACCA Btu/hr Btu/hr ❑Does Not Manual J or other methods Cooling: Btu/hr Cooling: ❑Not Observable approved by the code official. Btu/hr ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) Project Title: Tooth Time Data filename: Untitled.rck 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Report date: 05/31/18 Page 2 of 9 Section A protective covering is installed [FO11]2 to protect exposed exterior # Foundation Inspection Plans Verified Field Verified minimum of 6 in, below grade. & Req.ID Value Value Complies? Comments/Assumptions 402.1.1 [F04]1 Conditioned basement wall R- insulation R -value. Where interior R -❑Complies See the Envelope Assemblies insulation is used, verification R- R- ❑Does Not table for values. may need to occur during ❑Not Observable Insulation Inspection. Not []Not Applicable required in warm -humid locations in Climate Zone 3. 303.2 [F05]1 Conditioned basement wall insulation installed per ❑Complies Requirement will be met. manufacturer's instructions. ❑Does Not 402.2.9 Conditioned basement wall [F06]1 insulation depth of burial or distance from top of wall. 303.2.1 A protective covering is installed [FO11]2 to protect exposed exterior insulation and extends a minimum of 6 in, below grade. 403.9 Snow- and ice -melting system [FO12]2 controls installed. Additional Comments/Assumptions: 1 High Impact (Tier 1) Project Title: Tooth Time Data filename: Untitled.rck ❑Not Observable ❑Not Applicable ft ft ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable See the Envelope Assemblies table for values. Requirement will be met. 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Report date: 05/31/18 Page 3 of 9 Section # Framing / Rough -in Inspection Plans Verified Field Verified & Req.ID Value Value 402.1.1, Glazing U -factor (area -weighted U- 402.3.1, average). 0- 402.3.3, 402.5 [FR2]1 303.1.3 U -factors of fenestration products [FR4]1 are determined in accordance with the NFRC test procedure or taken from the default table. 402.4.1.1 Air barrier and thermal barrier [FR23]1 installed per manufacturer's instructions. 402.4.3 Fenestration that is not site built [FR20]1 is listed and labeled as meeting AAMA /WDMA/CSA 101/i.5.2/A440 or has infiltration rates per NFRC 400 that do not exceed code limits. 402.4.5 IC -rated recessed lighting fixtures [FR16]2 sealed at housing/interior finish and labeled to indicate :52.0 cfm leakage at 75 Pa. 403.3.1 Supply and return ducts in attics [FR12]1 insulated >= R-8 where duct is >= 3 inches in diameter and >_ R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. 403.3.5 Building cavities are not used as [FR15]3 ducts or plenums. 403.4 HVAC piping conveying fluids R- [FR17]z above 105 °F or chilled fluids R' below 55 °F are insulated to 2oR- 3. 403.4.1 Protection of insulation on HVAC [FR24]1 piping. 403.5.3 Hot water pipes are insulated to R- [FR18]2 >_R-3. R 403.6 Automatic or gravity dampers are [FR19]2 installed on all outdoor air intakes and exhausts. Additional Comments/Assumptions: 1 High Impact (Tier 1) Complies? ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable Comments/Assumptions See the Envelope Assemblies table for values. Requirement will be met. Requirement will be met. Requirement will be met. Requirement will be met. Requirement will be met. 2 Medium impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Tooth Time Report date: 05/31/18 Data filename: Untitled.rck Page 4 of 9 1 High Impact (Tier 1) Project Title: Tooth Time Data filename: Untitled.rck 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Report date: 05/31/18 Page 5 of 9 Section # Insulation Inspection plans Verified Field Verified & Req.ID Value Value Complies? Comments/Assumptions 303.1 All installed insulation is labeled [IN13]2 or the installed R -values ❑Complies Requirement will be met. provided. ❑Does Not ❑Nat Observable 402.1.1, Wall insulation R -value. If this is a R -❑Not Applicable 402.2.5, 402.2.6 mass wall with at least 1/z of the wall insulation on the wall R ❑Wood El Wood ❑Complies ❑Does Not See the Envelope Assemblies table for values. [IN3]1 exterior, the exterior insulation Mass ❑ Mass ❑Not Observable requirement applies (FR10). Steel ❑ ❑ Steel ❑Not Applicable 303.2 [IN4]1 Wall insulation is installed per manufacturer's instructions. ❑Complies Requirement will be met. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Tooth Time Report date: 05/31/18 Data filename: Untitled.rck Page 6 of 9 Section # Final Inspection Provisions & Req.ID 402.1.1, Ceiling insulation R -value. 402.2.1, 402.2.2, 402.2.6 [FI1]1 303.1.1.1, Ceiling insulation installed per 303.2 manufacturer's instructions. [FI2]1 Blown insulation marked every 300 ft2. 402.2.3 Vented attics with air permeable [F122]2 insulation include baffle adjacent to soffit and eave vents that 403.3.3 extends over insulation. 402.2.4 Attic access hatch and door [FI311 insulation >R -value of the adjacent assembly. 402.4.1.2 Blower door test @ 50 Pa. <=5 [FI17]1 ach in Climate Zones 1-2, and <=3 ach in Climate Zones 3-8, 403.3.4 Duct tightness test result of <=4 [FI4]1 cfm/100 ft2 across the system or <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough -in tests, verification may need to occur during Framing Inspection. 403.3.3 Ducts are pressure tested to [FI27]1 determine air leakage with either: Rough -in test: Total leakage measured with a pressure differential of 0.1 inch w.g, across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated [FI24]1 by manufacturer at <=2% of design air flow. 403.1.1 Programmable thermostats [F19]2 installed for control of primary heating and cooling systems and initially set by manufacturer to code specifications. 403.1.2 Heat pump thermostat installed [FI10]2 on heat pumps. 403.5.1 Circulating service hot water [FI 11]2 systems have automatic or accessible manual controls. 1 High Impact (Tier 1) Project Title: Tooth Time Data filename: Untitled.rck Pians Verified Value ❑ Wood ❑ Steel R- ACH 50 = cfm/100 ft2 cfm/100 ft2 Field Verified Value R- E] Wood ❑ Steel Lla ACH 50 = cfm/100 ft2 cfm/100 ft2 Complies? ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable Com ments/Assumptions See the Envelope Assemblies table for values. Requirement will be met. Requirement will be met. Requirement will be met. Requirement will be met, 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Report date: 05/31/18 Page 7 of 9 Section # Final inspection Provisions & Req.ID 403.6.1 All mechanical ventilation system [F125 12 fans not part of tested and listed HVAC equipment meet efficacy and air flow limits. 403.2 Hot water boilers supplying heat [FI26]2 through one- or two -pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor temperature. 403.5.1.1 Heated water circulation systems [FI28]2 have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply pipe. Gravity and thermos - syphon circulation systems are not present. Controls for circulating hot water system Pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set -point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems [FI29]2 comply with IEEE 515.1 or UL 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. 403.5.2 Water distribution systems that [F130]2 have recirculation pumps that pump water from a heated water supply pipe back to the heated water source through a cold water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units [FI31]2 tested in accordance with CSA 855.1. Potable water -side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75% of lamps in permanent [F16]1 fixtures or 75% of permanent fixtures have high efficacy lamps. Does not apply to low -voltage lighting. 404.1.1 Fuel gas lighting systems have [F123]3 no continuous pilot light. 1 High Impact (Tier 1) Project Title: Tooth Time Data filename: Untitled.rck Plans Verified Field Verified Value Value Complies? ❑Complies []Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not []Not Observable ❑Not Applicable ❑Complies []Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Comments/Assumptions Report date: 05/31/18 Page 8 of 9 —serhan---- # Final Inspection Provisions plans Verified Field Verified & Req.lD Value Value Complies? 401.3 Compliance certificate posted. -- [FI7]2 ❑Complies ❑Does Not ❑Not Observable 303.3 Manufacturer manuals for ❑Not Applicable [FI18]3 mechanical and water heating ❑Complies systems have been provided. f1Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) Project Title: Tooth Time Data filename: Untitled.rck Comments/Assumptions Requirement will be met. 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Report date: 05/31/18 Page 9 of 9 2015 iECC Energy Efficiency Certificate Above -Grade Wall ".00 Below -Grade Wall 38.00 Floor 0.00 Ceiling / Roof 98.00 Ductwork (unconditioned spaces): Window 0.29 Door 0.29 , MR Heating System: Cooling System: Water Heater: Name: Date: Comments