LOAD SHORT FORM - 18-00295 - 773 S 2275 W - New SFR
ft Load Short Form Job: SF15B9 �� Date: 5/30/18 Entire House By: Vince Byram High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 ROOM NAME Area (ft2) Design Information Htg AVF (cfm) Clg AVF (cfm) Htg Clg Infiltration 131 Outside db (°F) -6 89 Method Simplified Inside db (°F) 70 75 Construction quality Semi -tight Design TD (°F) 76 14 Fireplaces 0 Daily range - H 82 80 Inside humidity (%) 50 50 917 63 Moisture difference (gr/Ib) 62 -31 2184 1471 HEATING EQUIPMENT 84 COOLING EQUIPMENT Make Goodman Mfg. 2284 362 Make Goodman Mfg. 21 Trade GOODMAN 23 626 Trade GOODMAN; JANITROL; AMANA DISTI... Model GMSS920603BN 2 Room8 Cond GSX130301 B 18266 AHRI ref 7367472 465 448 Coil CAPF3030N6D 77F Q77G n,— AHRI ref 6497552 Efficiency 92.1 AFUE Efficiency 11.3 EER, 13.5 SEER Heating input 60000 Btuh Sensible cooling 19600 Btuh Heating output 55000 Btuh Latent cooling 8400 Btuh Temperature rise 64 °F Total cooling 28000 Btuh Actual air flow 933 cfm Actual air flow 933 cfm Air flow factor 0.025 cfm/Btuh Air flow factor 0.057 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Room10 50 909 131 23 8 Room11 50 97 53 2 3 Room9 121 2849 1961 72 112 Room17 245 3243 1402 82 80 Room 15 42 2460 917 63 53 Room14 138 2184 1471 56 84 Room13 96 2284 362 58 21 Room7 23 626 43 16 2 Room8 709 18266 7816 465 448 Rnnm19 77F Q77G n,— . r i . L I -fG M) "I L.S Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ,— 1 wrlihtSC)ft 2018 -May -30 07:38:26 ,�.�., � Right-SuiteRO Univ ersa1201717.0.10 RSU20477 . CCXPage 1 ...slwrightsoftware\Roberts\S15B9 harford plan.rup Calc = MJ8 House Front faces: E Entire House d 1697 36692 16299 933 933 Other equip loads 10132 768 Equip. @ 0.94 RSM 16043 Latent cooling 0 TnTAI Q nconn I ncnnn I - I IuJI 'tUUG't IuultJ yJJ 29JJ Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. s wri htSOft2018-May-30 07:38:26 Rig ht-Suite®Universal 201717.0.10 RSU20477 ...s\wrightsoftware\Roberts\S15139 harford plan.rup Calc = MJ8 House Front faces: E Paget Building Analysis Job: SF15B9 wrig4. 1t$oft Date: 5/30/18 Entire House By: Vince Byram High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email highcountryph@yahoo.com Project• • For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Component Design Conditions % of load Walls Location: 11073 Indoor: Heating Cooling Idaho Falls, ID, US 12.8 Indoor temperature (°F) 70 75 Elevation: 4741 ft Ceilings Design TD (°F) 76 14 Latitude: 44'N 4.3 Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Drybulb (°F) -6 89 Infiltration: 0 Dailyrange (°F) - 34 ( H ) Method Simplified 12.7 Wet bulb (°F) - 60 Construction quality Semi -tight Adjustments Wind speed (mph) 15.0 7.5 Fireplaces 0 1 46824 100.0 Component Btu N112 Btuh % of load Walls 4.9 11073 23.6 Glazing 24.3 5993 12.8 Doors 12.9 543 1.2 Ceilings 1.5 1468 3.1 Floors 4.3 4148 8.9 Infiltration 2.0 5164 11.0 Ducts 8303 17.7 Piping 0 0 Humidification 5961 12.7 Ventilation 4171 8.9 Adjustments 0 Total 1 46824 100.0 Cooling Component Btuh/ft2 Btuh % of load Walls 0.5 1064 6.2 Glazing 35.7 8805 51.6 Doors 3.1 132 0.8 Ceilings 0.8 811 4.8 Floors 0.1 66 0.4 Infiltration 0.2 512 3.0 Ducts 4909 28.8 Ventilation 768 4.5 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 1 17067 100.0 Latent Cooling Load = 0 Btuh Overall U -value =0.069 Btuh/ft2-°F Data entries checked. p1' 4V1'[ 2018 -May -3007:38:26 1'- Rig Universal 2017 17.0.10 RSU20477 O C ...s\wrightsoftware\Roberts\S15B9 harford plan.rup Calc = MJ8 House Front faces: E Page 1 Component Constructions Job: SF15B9 W rightsoft Date: 5/30/18 Entire House By: Vince Byram High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Location: Or Indoor: Heating Cooling Idaho Falls, ID, US Loss Indoor temperature (°F) 70 75 Elevation: 4741 ft ft' Design TD (°F) 76 14 Latitude: 44°N Btuh/ft' Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Dry bulb (°F) -6 89 Infiltration: n 561 Dailyrange (°F) - 34 ( H ) Method Simplified 0.47 Wet bulb (°F) - 60 Construction quality Semi -tight 0.065 Wind speed (mph) 15.0 7.5 Fireplaces 0 281 Construction descriptions Or Area U -value Insul R Htg HTM Loss CIg HTM Gain 0 24.3 ft' BtuhtW-'F ft-'F/Btuh Btuh M2 Btuh Btuh/ft' Btuh Walls 18.4 619 w 144 0.320 0 24.3 3502 33.5 Frm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int n 561 0.065 22.0 4.94 2771 0.47 266 fnsh, 2"x6" wood frm, 16" o.c. stud: Frm wall, vnl ext, 3/8" wood shth, e 593 0.065 22.0 4.94 2930 0.47 281 r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud s 531 0.065 22.0 4.94 2625 0.47 252 w 556 0.065 22.0 4.94 2747 0.47 264 all 2242 0.065 22.0 4.94 11073 0.47 1064 Partitions (none) Windows 61 C: 61 C; 6.67 ft head ht Doors metal: Door, mtl pur core type Ceilings 166-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh Floors 19A-30bscp: Part floor, carpet flr fnsh, r-30 ins, frm fir, 12" thkns, 5/8" gypsum board int fnsh 2213-10cpm: Bg floor, heavy dry or light damp soil, on grade depth, r-10 edge ins, carpet flr fnsh n 4 0.320 0 24.3 97 10.4 41 e 65 0.320 0 24.3 1577 33.5 2171 S 34 0.320 0 24.3 817 18.4 619 w 144 0.320 0 24.3 3502 33.5 4822 all 246 0.320 0 24.3 5993 31.1 7654 e 42 0.170 10.5 12.9 543 3.14 132 966 0.020 50.0 1.52 1468 0.84 811 166 0.034 30.0 2.17 359 0.40 66 122 0.355 10.0 27.0 3292 0 0 18 0.355 10.0 27.0 497 0 0 all 140 0.355 10.0 27.0 3789 0 0 LI 1 2018 -May -30 07:38:26 Tyr WrightSOft Rig ht -Su ite@ Universal 2017 17.0. 10 RSU20477 Page 1 s\wrightsoftware\Roberts\S1589 harford plan.rup Calc = MJ8 House Front faces: E . Wt'��I"1tSCl Project Summa Job: SF15B9 1 Date: 5/30/18 Entire House By: Vince Byram High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Notes: Weather: Idaho Falls, ID, US Winter Design Conditions Summer Design Conditions Trade GOODMAN Outside db -6 °F Outside db 89 °F Inside db 70 °F Inside db 75 °F Design TD 76 °F Design TD 14 'F Daily range H AHRI ref 6497552 Relative humidity 50 % AFUE Moisture difference -31 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 28389 Btuh Structure 11390 Btuh Ducts 8303 Btuh Ducts 4909 Btuh Central vent (59 cfm) 4171 Btuh Central vent (59 cfm) 768 Btuh Humidification 5961 Btuh Blower 0 Btuh Piping 0 Btuh 0.025 cfm/Btuh Air flow factor Equipment load 46824 Btuh Use manufacturer's data n in H2O Static pressure Rate/swing multiplier 0.94 Infiltration Equipment sensible load 16043 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure -712 Btuh Ducts -108 Btuh Heating Cooling Central vent (59 cfm) -1068 Btuh Area (ft2) 1697 1697 Equipment latent load 0 Btuh Volume (ft') 16968 16968 Air changes/hour 0.26 0.14 Equipment total load 16043 Btuh Equiv. AVF (cfm) 74 40 Req. total capacity at 0.70 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade GOODMAN; JANITROL; AMANA DISTI... Model GMSS920603BN Cond GSX130301 B AHRI ref 7367472 Coil CAPF3030N6D AHRI ref 6497552 Efficiency 92.1 AFUE Efficiency 11.3 EER, 13.5 SEER Heating input 60000 Btuh Sensible cooling 19600 Btuh Heating output 55000 Btuh Latent cooling 8400 Btuh Temperature rise 64 °F Total cooling 28000 Btuh Actual air flow 933 cfm Actual air flow 933 cfm Air flow factor 0.025 cfm/Btuh Air flow factor 0.057 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WI's#soft 2018 -May -3007:38:26 }ARight-Suite® Universal 2017 17.0.10 RSU20477 Page 1 s\wrightsoftware\Roberts\S15B9 harford plan.rup Calc = MJ8 House Front faces: E AED Assessment Job: SF15B9 wrihtsuft Date: 5/30/18 Entire House By: Vince Byram High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com eroject intormation For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Test for Adequate Exposure Diversity rwrofnay / FbM ♦ A. AED 1- Maximum hourly glazing load exceeds average by 47.0°/x. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 1151 Btuh (PFG-1.3*AFG) +tiW I'E 2018 -May -30 07:38:26 Right -Suite® Universal 2017 17.0. 10 RSU20477 Page 1 JCDt ..s\wrightsoftware\Roberts\S15B9 harford plan.rup Calc = MJ8 House Front faces: E Design Conditions Location: Indoor: Heating Cooling Idaho Falls, ID, US Ind oor temperature (°F) 70 75 Elevation: 4741 ft Design TD (°F) 76 14 Latitude: 44'N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Dry bulb (°F) -6 89 Infiltration: Dailyrange (°F) - 34 ( H ) Wet bulb ('F) - 60 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity rwrofnay / FbM ♦ A. AED 1- Maximum hourly glazing load exceeds average by 47.0°/x. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 1151 Btuh (PFG-1.3*AFG) +tiW I'E 2018 -May -30 07:38:26 Right -Suite® Universal 2017 17.0. 10 RSU20477 Page 1 JCDt ..s\wrightsoftware\Roberts\S15B9 harford plan.rup Calc = MJ8 House Front faces: E wrightsoft Right -M Worksheet Entire House High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Job: SF15B9 Date: 5/30/18 By: Vince Byram 1 Room name Entire House Room10 2 Exposed wall 253.0 ft 9.0 ft 3 Room height 10.0 ft d 10.0 ft heat/cool 4 Room dimensions 9.0 x 5.5 ft 5 Room area 1696.8 ft2 49.5 ft' Ty Construction U -value Or HTM Area (ft) Load Area (W) I Load number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vy Frm wall, vnl ext, 3 0.065 n 4.94 0.47 565 561 2771 266 0 0 0 0 G 61C 0.320 n 24.32 10.37 4 0 97 41 0 0 0 0 Frm wall, vnl ext, 3 0.065 e 4.94 0.47 700 593 2930 281 0 0 0 0 61 C 0.320 e 24.32 33.49 65 0 1577 2171 0 0 0 0 11 metal 0.170 e 12.92 3.14 42 42 543 132 0 0 0 0 Frm wall, vnl ext, 3 0.065 s 4.94 0.47 565 531 2625 252 0 0 0 0 61C 0.320 s 24.32 18.43 34 0 817 619 0 0 0 0 Frm wall, vnl ext, 3 0.065 w 4.94 0.47 700 556 2747 264 90 90 445 43 61C 0.320 w 24.32 33.49 144 0 3502 4822 0 0 0 0 C 16B-50ad 0.020 1.52 0.84 966 966 1468 811 50 50 75 42 F 19A-30bsco 0.034 2.17 0.40 166 166 359 66 0 0 0 0 F 22B-10cpm 0.355 26.98 0.00 731 122 3292 0 0 0 0 0 F 22B-10cpm 0.355 26.98 0.00 69 18 497 0 0 0 0 0 6 c) AED excursion 1 1151 11 Envelope loss/gain 23225 10878 520 74 12 a) Infiltration 5164 512 184 18 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 28389 11390 704 92 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 28389 11390 704 92 15 Duct loads 29% 43% 8303 4909 29% 43% 206 40 Total room load 36692 16299 909 131 Air required (cfm) I I I 933 9331 I I 23 I 8 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. Vtrrightscaft 2018 -May -30 07:38:26 Rig ht -Su iteO Universal 2017 17.0. 10 RSU20477 Page 1 s\wrightsoftware\Roberts\S15139 harford plan.rup Calc = MJ8 House Front faces: E + wrightsok Right -J® Worksheet Job: SF15B9 Entire House Date: 5/30118 High Country Heating By: Vince Byram P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room11 Room9 2 Exposed wall 0 ft 22.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 9.0 x 5.5 ft 11.0 x 11.0 ft 5 Room area 49.5 ft' 121.0 ft2 Ty Construction U -value Or HTM Area (ft') Load I Area(f t') Load number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Frm wall, vnl ext, 3 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 61 C0.320 n 24.32 10.37 0 0 0 0 0 0 0 0 Frm wall, vnl ext, 3 0.065 e 4.94 0.47 0 0 0 0 0 0 0 0 61C 0.320 e 24.32 33.49 0 0 0 0 0 0 0 0 11 metal 0.170 e 12.92 3.14 0 0 0 0 0 0 0 0 Frm wall, vnl ext, 3 0.065 s 4.94 0.47 0 0 0 0 110 110 543 52 61 C 0.320 s 24.32 18.43 0 0 0 0 0 0 0 0 Frm wall, vnl ext, 3 0.065 w 4.94 0.47 0 0 0 0 110 85 420 40 61C 0.320 w 24.32 33.49 0 0 0 0 25 0 608 837 C 1613-50ad 0.020 1.52 0.84 50 50 75 42 121 121 184 102 F 19A-30bscD 0.034 2.17 0.40 0 0 0 0 0 0 0 0 F 22B-10cpm 0.355 26.98 0.00 0 0 0 0 0 0 0 0 F 22B-10cpm 0.355 26.98 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -4 294 Envelope loss/gain 75 37 1755 1326 12 a) Infiltration 0 0 449 45 b) Roam ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 75 37 2204 1370 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 75 37 2204 1370 15 Duct loads 29% 43% 22 16 29% 43% 645 591 1 Total room load 971 531 28491 1961 1 Air required (cfm) 1 2 3 1 1 72 112 Calculations approved by ACCA to meet all reouirements of Manual J 8th Ed. uvrpgFttlsTt 2018 -May -30 07:38:26 Right-SuiteO Universal 2017 17.0.10 RSU20477 Page2 17i t Ae ..s\wrightsoftware\Roberts\S15B9 harford plan.rup Calc = MJ8 House Front faces: E wrightsoft Right -M Worksheet Job: SF15B9 Entire House Date: 5/30/18 High Country Heating By: Vince Byrom P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room17 Room15 2 Exposed wall 22.5 ft 16.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 244.5 ft 1.0 x 42.0 ft 5 Room area 244.5 ft' 42.0 ft' Ty Construction U -value Or HTM Area (ft') I Load I Area (ft') I Load number (Btuh/ft'-°F (Bt uh/f t') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross I N/P/S Heat Cool 6 Vj/ Frm wall, vnl ext, 3 0.065 n 4.94 0.47 0 0 0 0 35 35 173 17 O� 61 C 0.320 n 24.32 10.37 0 0 0 0 0 0 0 0 Frm wall, vnl ext, 3 0.065 e 4.94 0.47 75 57 281 27 80 65 321 31 61C 0.320 e 24.32 33.49 18 0 440 606 15 0 365 502 11 metal 0.170 e 12.92 3.14 0 0 0 0 0 0 0 0 Frm wall, vnl ext, 3 0.065 s 4.94 0.47 150 142 703 67 45 45 222 21 61C 0.320 s 24.32 18.43 8 0 188 143 0 0 0 0 Frm wall, vnl ext, 3 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 61C 0.320 w 24.32 33.49 0 0 0 0 0 0 0 0 C 16B-50ad 0.020 1.52 0.84 245 245 372 205 42 42 64 35 F 19A-30bsco 0.034 2.17 0.40 0 0 0 0 0 0 0 0 F 22B-10cpm 0.355 26.98 0.00 0 0 0 0 0 0 0 0 F 22B-10cpm 0.355 - 26.98 0.00 27 2 66 0 42 16 432 0 61 c) AED excursion -114 Envelope loss/gain 2050 934 1577 j 12 a) Infiltration 459 46 327 32 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 2509 979 1903 641 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2509 979 1903 641 15 Duct loads 29% 43% 734 422 29% 43% 557 276 Total room load 3243 1402 2460 917 Air required (cfm) I I I 82I 80 I 63I 53 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed 414- wrighrtsc>ft 2018 -May -30 07:38:26 ^r- Rig ht-Suite®Universa1201717.0.10 RSU20477 Page3 ...s\wrightsoftware\Roberts\S1589 harford plan.rup Calc = MJ8 House Front faces: E -r wrightsoft- Right -M Worksheet Job: SF15B9 Entire House Date: 5/30/18 High Country Heating By: Vince Byrom P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room14 Room13 2 Exposed wall 11.5 ft 20.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 11.5 x 12.0 ft 8.0 x 12.0 ft 5 Room area 138.0 ft' 96.0 ft' Ty Construction LI -value Or HTM Area (ft') Load Area (ft') Load number (Btuh/f t' -°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross I N/P/S j Heat I Cool j Gross I N/P/S j Heat Coal 6 WC, Frm wall, vnl ext, 3 0.065 n 4.94 0.47 0 0 0 0 120 116 573 55 61 C 0.320 n 24.32 10.37 0 0 0 0 4 0 97 41 Frm wall, vnl ext, 3 0.065 e 4.94 0.47 115 91 450 43 80 80 395 38 61C 0.320 e 24.32 33.49 24 0 584 804 0 0 0 0 11 metal 0.170 e 12.92 3.14 0 0 0 0 0 0 0 0 Frm wall, vnl ext, 3 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 61 C 0.320 s 24.32 18.43 0 0 0 0 0 0 0 0 VL Frm wall, vnl ext, 3 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 L -G 61C 0.320 w 24.32 33.49 0 0 0 0 0 0 0 0 C 1613-50ad 0.020 1.52 0.84 138 138 210 116 96 96 146 81 F 19A-30bscD 0.034 2.17 0.40 98 98 212 39 68 68 147 27 F 22B-10cpm 0.355 26.98 0.00 0 0 0 0 0 0 0 0 F 22B-10cpm 0.355 26.98 0.00 0 0 0 0 0 0 0 0 61 c) AED excursion 13 130 Envelope loss/gain 1455 1005 1 1 1359 213 12 a) Infiltration 235 23 408 40 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1690 1028 1767 253 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1690 1028 1767 253 15 Duct loads 29% 43% 494 443 29% 43% 517 109 Total room load 2184 1471 2284 362 Air required (cfm) I I 56I 84 I 58I 21 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed -Ff f- 11.,ightsoTt 2018 -May -30 07:38:26 Right-Suite®Universal 201717.0.10 RSU20477 Page4 s\wrightsoftware\Roberts\S15B9 harford plan.rup Calc = MJ8 House Front faces: E - - wricghtsoft Right -J® Worksheet Job: S Date: 5/3011830118 Entire House High Country Heating By: Vince Byram P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room7 Room8 2 Exposed wall 5.0 ft 117.0 ft 3 Room height 10.0 it heat/cool 10.0 ft heat/cool 4 Room dimensions 5.0 x 4.5 ft 1.0 x 708.8 it 5 Room area 22.5 ft' 708.8 ft' T Y Construction U -value Or HTM Area ft' ( ) Load Area ft' ( ) Load number (Bt uh/f t2_ °F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool i Gross N/P/S j Heat Cool Gross I N/P/S j Heat 1 Cool 6 Vjl Frm wall, vnl ext, 3 0.065 n 4.94 0.47 0 0 0 0 260 260 1284 123 C, 61 C 0.320 n 24.32 10.37 0 0 0 0 0 0 0 0 Frm wall, vnl ext, 3 0.065 e 4.94 0.47 50 50 247 24 300 250 1236 119 6 1 C 0.320 e 24.32 33.49 0 0 0 0 8 0 188 260 11 metal 0.170 e 12.92 3.14 0 0 0 0 42 42 543 132 Vy Frm wall, vnl ext, 3 0.065 s 4.94 0.47 0 0 0 0 260 234 1157 111 G61C 0.320 s 24.32 18.43 0 0 0 0 26 0 628 476 Frm wall, vnl ext, 3 0.065 w 4.94 0.47 0 0 0 0 350 256 1265 121 61C 0.320 w 24.32 33.49 0 0 0 0 94 0 2286 3148 C 16B-50ad 0.020 1.52 0.84 0 0 0 0 0 0 0 0 F 19A-30bsco 0.034 2.17 0.40 0 0 0 0 0 0 0 0 F 22B-10cpm 0.355 26.98 0.00 23 5 135 0 709 117 3157 0 F 22B-10cpm 0.355 26.98 0.00 0 0 0 0 0 0 0 0 61 c) AED excursion 1-41 11 1 735 Envelope loss/gain 382 20 1 1 11744 5225 12 a) Infiltration 102 10 2388 237 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 484 30 14132 5462 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 484 30 14132 5462 15 Duct loads 29% 43% 142 13 29% 43% 4133 2354 Air 6161 42I 18465 2611 7816 rel quomdl (cfm) I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. lyy�j htcrft 2018 -May -3007:38:26 9 Right-Suitee Universal 2017 17.0.10 RSU20477 Pages ...s\wrightsoftware\Roberts\S15B9 harford plan.rup Calc = MJ8 House Front faces: E - - wrightsoft, Right -M Worksheet Job: SF15B9 Entire House Date: 5/30118 High Country Heating By: Vince Byram P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room12 2 Exposed wall 30.0 ft 3 Room height 10.0 ft heat/cool 4 Room dimensions 15.0 x 15.0 ft 5 Room area 225.0 ft' Ty Construction U -value Or HTM Area (ft') Load Area Load number (Btuh/ft'-°F (Bt uh/f t') or perimeter (ft) (Btuh) or perimeter Heat Cool Gross I N/P/S Heat I Cool Gross N/P/S Heal Cool 6 b}f Frm wall, vnl ext, 3 0.065 n 4.94 0.47 150 150 741 71 C 61C 0.320 n 24.32 10.37 0 0 0 0 Frm wall, vnl ext, 3 0.065 e 4.94 0.47 0 0 0 0 61C 0.320 e 24.32 33.49 0 0 0 0 11 metal 0.170 e 12.92 3.14 0 0 0 0 Vy Frm wall, vnl ext, 3 0.065 s 4.94 0.47 0 0 0 0 C, 61 C 0.320 s 24.32 18.43 0 0 0 0 Frm wall, vnl ext, 3 0.065 w 4.94 0.47 150 125 617 59 61C 0.320 w 24.32 33.49 25 0 608 837 C 16B-50ad 0.020 1.52 0.84 225 225 342 189 F 19A-30bsco 0.034 2.17 0.40 0 0 0 0 F 22B-10cpm 0.355 26.98 0.00 0 0 0 0 F 22B-10cpm 0.355 26.98 0.00 0 0 0 0 6 c) AED excursion 279 Envelope loss/gain 2308 1436 12 a) Infiltration 612 61 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 2921 1497 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2921 1497 15Duct loads 29% 43 % 854 645 1 Total room load 37751 21421 Air required (cfm) I 1 1 96 123 1 1 1 1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed � vw r'jght25v 2018 -May -30 07:38:26 � Right-Suite®Universal 2017 17.0.10 RSU20477 Page6 s\wrightsoftware\Rober1s\S15B9 harford plan.rup Calc = MJ8 House Front faces: E 0 Main Job #: SF151139 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryph@yahoo.com Scale: 1 : 58 Page 1 Right -Suite® Universal 2017 17.0.10 RSU20477 2018 -May -30 07:39:04 .e\Roberts\S15B9 harford plan.rur 2nd Story Job #: SF15139 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone:208-745-8056 Fax: 208-745-0817 highcountryph@yahoo.com Scale: 1 :58 Page 2 Rig ht -Su ite® Universal 2017 17.0.10 RSU20477 2018 -May -30 07:39:04 .e\Roberts\S15B9 hartord planxuF wrightsoft Duct System Summary Date: 5/3015 305 9 8 Entire House By: Vince Byram High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.70 in H2O 0.36 in H2O 0.34 in H2O 0.178 / 0.162 in H2O 0.078 in/100ft 933 cfm 438 ft Cooling 0.70 in H2O 0.36 in H2O 0.34 in H2O 0.178 / 0.162 in H2O 0.078 in/100ft 933 cfm Name Design (Btu h) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Room10 h 909 23 8 0.099 6.0 Ox 0 ShMt 20.0 160.0 st2 Room11 C 53 2 3 0.099 6.0 Ox 0 ShMt 14.0 165.0 st2 Room12 c 1071 48 61 0.084 6.0 0x0 ShMt 21.0 190.0 st1 Room12-A c 1071 48 61 0.078 6.0 Ox 0 ShMt 28.5 200.0 st1 Room13 h 2284 58 21 0.082 6.0 Ox 0 ShMt 26.0 190.0 st1 Room14 c 1471 56 84 0.095 6.0 Ox 0 ShMt 12.0 175.0 st1 Rocm15 h 2460 63 53 0.093 6.0 OX 0 ShMt 15.0 175.0 st2 Room17 h 3243 82 80 0.094 6.0 Ox 0 ShMt 9.0 180.0 st2 Room7 h 626 16 2 0.106 6.0 Ox 0 ShMt 7.5 160.0 st1 Rooms h 3044 77 75 0.113 6.0 Ox 0 ShMt 21.5 135.0 st2 Rooms -A h 3044 77 75 0.095 6.0 Ox 0 ShMt 7.5 180.0 st2 Rooms -B In 3044 77 75 0.099 6.0 Ox 0 ShMt 24.5 155.0 st2 Rooms -c h 3044 77 75 0.098 6.0 Ox 0 ShMt 27.0 155.0 st1 Room8-D h 3044 77 75 0.105 6.0 OX 0 ShMt 14.0 155.0 st1 Rooms -E h 3044 77 75 0.094 6.0 Ox 0 ShMt 18.5 170.0 st1 Room9 C 1961 72 112 0.107 6.0 Ox 0 ShMt 25.5 140.0 st2 2018 -May -30 07:38:27 WrlghtSaft Rig ht -Su ite®Universal 201717.0.10 RSU20477 Page 1 s\wrightsoftware\Roberts\S15B9 harford plan.rup Calc = MJ8 House Front faces: E Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 475 479 0.093 719 10.6 8 x 12 ShtMetl SO Peak AVF 458 454 0.078 687 10.8 8 x 12 ShtMetl 2018 -May -30 07:38:27 WrlghtSaft Rig ht -Su ite®Universal 201717.0.10 RSU20477 Page 1 s\wrightsoftware\Roberts\S15B9 harford plan.rup Calc = MJ8 House Front faces: E WtE�MtSSfRighuiteUnivrsa1201717,0,10 RU20477 2018 -May -30 07:38:27 Tr" Page2 s\wri g htsoftware\Robe rts\S 15 B 9 harford plan.rup Calc = M J 8 House Front faces: E Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Type Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb13 0x0 96 120 207.0 0.078 379 6.5 3.25x14 10x9 SJSp rt1 rb12 Ox 0 133 145 132.5 0.123 458 6.4 3.25x14 10x9 SJSp rt1 rb10 Ox 0 481 450 62.5 0.260 760 8.6 2-3.25x14 2-10x18 SJSp rb14 Ox 0 169 135 133.5 0.122 534 6.8 3.25x14 10x9 SJSp rt2 rb11 Ox 0 56 84 209.0 0.078 267 5.7 3.25x14 10x9 SJSp rt2 WtE�MtSSfRighuiteUnivrsa1201717,0,10 RU20477 2018 -May -30 07:38:27 Tr" Page2 s\wri g htsoftware\Robe rts\S 15 B 9 harford plan.rup Calc = M J 8 House Front faces: E Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 229 264 0.078 793 8.8 8 x 6 ShtMetl rt2 Peak AVF 224 219 0.078 807 8.3 8 x 5 ShtMetl WtE�MtSSfRighuiteUnivrsa1201717,0,10 RU20477 2018 -May -30 07:38:27 Tr" Page2 s\wri g htsoftware\Robe rts\S 15 B 9 harford plan.rup Calc = M J 8 House Front faces: E