HomeMy WebLinkAboutRHOMBUS CONTROLLER - 13-00438 - 340 & 330 N 12th W - In the Impact Area - Pier 340 - CUPSingle phase, duplex alternating pump control with override. The Model 122 control panel is designed to alternately control two 120, 208, or 240 VAC single phase pumps in water and sewage installations. The alternating action equalizes pump wear. In addition to the alternating pump control, this system provides override control should either pump fail. If an alarm condition occurs, an alarm switch activates the audio/visual alarm system. Common applications include pump chambers, sump pump basins, irrigation systems and lift stations. 1. Enclosure measures 10 X 10 X 6 inches (25.4 X 25.4 X 15.24 cm). Choice of NEMA 1 (steel for indoor use), or NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). Note: Options selected may increase enclosure size and change component layout. 2. Magnetic Motor Contactors control pumps by switching electrical lines. 3. HOA Switches for manual pump control (mounted on circuit board). 4. Control Circuit Board provides pump control and alternation. 5. Green pump Run Indicator Lights (mounted on circuit board). 6. Circuit Breakers (optional) provide pump disconnect and branch circuit protection. 7. Ground Lugs 8. Float Status Indicator Lights (mounted on circuit board). 9. Control and Alarm Power Indicator Lights (mounted on circuit board) 10. Auxiliary Alarm Contact, form C (mounted on circuit board). NOTE: Schematic is located inside the panel on enclosure cover. aSTANDARD ALARM PACKAGE 11. Red Alarm Beacon provides 360° visual check of alarm condition. Note: NEMA 1 style utilizes a door mounted indicator in lieu of a beacon. 12. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). Note: NEMA 1 style utilizes an internally mounted buzzer in lieu of horn. 13. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 14. Horn Silence Relay (mounted on circuit board). NOTE: other options available. Entire control system (panel and switches) is UL Listed to meet and/ or exceed industry safety standards Dual safety certification for the United States and Canada Standard package includes three 20' SJE SignalMaster° control switches Complete with step-by-step installation instructions AF Three-year limited warranty SEE PRICE BOOK FOR Model Shown 1221W114X6A Rh us.' PO Box 1708, Detroit Lakes, MN 56502' 1-888-DIAL-SJE • 1-218-847-1317 1-218-847-4617 Fax email: sje@sjerhombus.com vYww.sjerhoMbUS.00M 29' MODEL 1........................................................................... ALARM PACKAGE 0 =select options or no alarm package......................................................................................... 1 =alarm package (includes test/normal/silence switch, fuse, red light, & horn) .......................... ENCLOSURE RATING 1 W =Weatherproof, _NE MA4X(engineered thermoplastic)............................................................. STARTING DEVICE I 1 =magnetic motor contactor 120/208/240V............................................................................... 9 =magnetic motor contactor 120V only...................................................................................... PUMP FULL LOAD AMPS - 1 n _ n 7 El A 1 = 7-15 FLA ....... 2 =15-20 FLA ..... 3 = 20-30 FLA ..... PUMP DISCONNECTS E] 0 =no pump disconnect................................................................................................................ 4 =circuitbreaker 120V (select STARTING DEVICE option 9 above) .......................................... 120/208/240V (select STARTING DEVICE option 1 above) ............................. FLOAT SWITCH APPLICATION H or L = pump down or pump up (select 17 option).......................................................................... El X = no floats..................................................................................................................................... TONS Listed ENCLOSURE UPSIZE If you selected one or more of the * options, or two ** options, add a one-time $65.00 for NEMA 4X, $100 for NEMA 1 list enclosure upsize ................. See Price List -$35.00 ............ Base - $75.00 ............. Base ............. Base ............ Base ............:. Base .............. Base .............. Base ........ $10,00 ........... Base ............ $70.00 .......... $140.00 .............. Base ........ -$75.00 Total Options Enclosure Upsize TOTAL LIST PRICE CODE DESCRIPTION LIST PRICE Base W ................... Base ® 1A Red beacon only / no audio .............................. $20.00 CODE DESCRIPTION LIST PRICE H ................... (must select "0" for alarm package) -k* 10K Anti -condensation heater ................................................ $100.00 ® 1C Horn only / no visual .......................................... $20.00 11C NEMA 1 alarm panel........................................................1 $80.00 $65.00 (must select "0" for alarm package) ® 11D NEMA 4X alarm panel .................................................... $250.00 ®**3A Alarm flasher....................................................... $35.00 ®fir 14B Main disconnect (rotary style, mounted through door, non-fused ® �t 3B Manual alarm reset ............................. I............. $135.00 (must select circuit breaker) k 4A Redundant off ...................................................... $40.00 * 0-20 FLA (total of both pumps).. ............................. 11 ....... $320.00 (select Option 4D if floats included) 20-60 FLA (total of both pumps) ..................................... $360.00 ® 4B Red redundant off indicator & alarm ................ $60.00 ® 16A 10' cord in lieu of 20' (per float) ..................................... - $2.00 (must select Option 4A also) ® 16B 15' cord in lieu of 20' (per float) .................................... - $1.00 ® 4D Redundant off float ® 16C 30' cord in lieu of 20' (per float) ..................................... $5.00 (must select 4A option) (select 17 option) ....... $25.00 ® 16D 40' cord in lieu of 20' (per float) ..................................... $15.00 Q yF 5A Thermal cutout/heat sensor auto reset ............. $80.00 ® 17A SJE SignalMasterO / pipe clamp 0 (per float)...... ..... I ..... - $2.00 (for pumps w/thermal switch leads) ® 17B SJE SignalMaster® / externally weighted 0 (per float)...... $5.00 �d 5E Seal failure circuit & red indicator (2 wire) .... $395.00 ® 17C Sensor Float® / internally weighted A (per float) ............. $5.00 6A Auxiliary alarm contact, form C ® 17D Sensor Float® / externally weighted A (per float) ............. $7.00 (included as standard) .......................................... $0.00 ® 17E Sensor Float® Mini / pipe clamp A (per float) ............. - $2.00 ® 8A Elapsed time meter .......................................... $110.00 ® 17F Sensor Float® Mini / externally weighted A (per float) .... $5.00 ® �! 8C Event (cycle) counter .......................................... $90.00 ® 17J Sensor Float® / pipe clamp A (per float) ........................... $0.00 ® �k 9_A Pump overload ® 19B Lead lag selector switch .................................................... $15.00 specify amperage after number 9 followed by letter "A". ® 19F Fourth float to separate alarm function from lag ..........1. $25.00 Example: 912A = 12 amp pump. ® 19T TOA (Test/Off/Automatic) switches and pump run lights ® 0-25 FLA ........................................................ _ $370.00 through door mounted..................................................... $160.00 Ir ® 25-30 FLA .......................................................... $500.00 19U HOA (Hand/Off/Automatic) switches and pump run lights ® 10E Lockable latch - NEMA 4X ................................. $40.00 through door mounted..................................................... $150.00 ® 10E Lockable latch - NEMA 1 .................................... $40.00 ® 19X Door mounted pump run indicator ... ... _. ........................ $40.00 ®yt 10F Lightning arrestor (select pump circuit breaker) ...... $230.00 0 Mechanically -activated A Mercury -activated SAMPLE MODEL122W 9 0 4 Alarm Package L7 Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Options: Auxiliary alarm contact, form C, Elapsed time meter, event (cycle) counter, SJE SignalMaster° / pipe clamp 6A 8AC 17A 122 ..... See List Price 1 ................... Base W ................... Base 9 ................... Base 0 ................... Base 4 ................ $70.00 H ................... Base 6A .................. $0.00 8 A .............. $110.00 8C ................ $90.00 17A ................. -$6.00 Enclosure upsize ............ $65.00 TOTALLISTPRICE $XXXX.X, Cat PagePN1017379H ©SJE-Rhombui Q