Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PUMP TECH - 13-00438 - 340 & 330 N 12th W - In the Impact Area - Pier 340 - CUP
PumpTech Co., Inc. Duplex Hydromatic Estimate Phone: 208-529-6868 4444 So. Yellowstone Hwy. Wholesaler Station Toll Free: 800-427-6858 Idaho Falls, Idaho 83405 Fax: 208-529-4332 Customer: :Eagle Rock Engineering Date: Apr 9, 2014 Start up services and training are NOT included 'Taxes: Shipment: No State, Federal, Local or Other Taxes are included 2-4 Weeks After Approved Order FOB: Jobsite !Idaho Falls, Idaho 100% net 30 days No item not specifically mentioned is included IAttn: McKay Anderson This is a pre built sewage non clog lift station Phone: Job Name: Service: 1208-403-7932 Packaged Non Clog Lift Station: Sewage: 60 GPM @ 6'TDH Description jNo electrical installation is provided Price 2: Pump Model: 2'Rail System: 2 Lift Chain: 'Hydromatic submersible non -clog pump model BV -40, w/A HP motor, 1550 RPM, 1 ph/60cy/1 15v, 30' power cord 12" EZ out rail system w/ stainless steel rails i 15' SS Lift Chain, 3/16" Part# 12316-012-5 $ $ $ 852.00 1,722.83 234.00 1 Control Panel: Duplex Control Panel in NEMA 4X enclosure, w/ flashing alarm light, floats, ,alternating circuit, HOA switch, 1 ph/60cy/1 15 $ 1,966.80 4 Floats: Hydromatic model 3900 float switches, 50' cord $ 180.10 !Float Tree: Hydromatic float tree $ 100.80 1 Junction Box: Model PL -JX -6 Simplex electrical junction box $ 342.58 1 Pump Sump: Fiberglass basin: 60" diameter x 120" deep, model with factory built discharge piping, valves, hatch, and anti float flange. $ 6,330.12 Freight: Incoming freight $ 1,200.00 Net Price: $ 12,929.22 Start Up Services: Start up services and training are NOT included 'Taxes: Shipment: No State, Federal, Local or Other Taxes are included 2-4 Weeks After Approved Order FOB: Jobsite Terms: 100% net 30 days No item not specifically mentioned is included This is a pre built sewage non clog lift station No excavation or backfill is provided. jNo electrical installation is provided Terms: Net 30 days PumpTech Co. Inc. Quoted by: Barry Cazier "Your Total Pump Supplier" Phone: 208-529-6868 Specialists in Pump Design NOTES: BASIN LENGTHS AND DEPTHS ARE INSIDE DIMENSIONS BASIN COLOR IS GREEN 3) ALL DIMENSIONS ARE +/- 1/8' D OF RECESSED ' HANDLE & HASP 1 � I I I I 1 1 it I� l II 11 II � I1 1 11 1 II 1 ELD VERIFY .EVATION -2' ' SSED HINGES ELEV. GROUND 0'.00" TOP BASIN 12'' 2' FULL COUPLING NEMA-GX JUNCTION BOX S.S. FLOAT BRACKET At-, INV. ELEV. . -F4' C.I. INLET HUB / OR ADAPT -A -FLEX - (FIELD INSTALLED) p ELEV. 5 (60") HIGH LEVEL ALARM ELEV, ° '(72") SECONDARY PUMP ON ELEV. 7' (84" ) PRIMARY PUMP ON ELEV. 9' ( 108") .- PUMP OFF ELEV. 10' (120" ) PUMP INFORMATION: TYPE: ❑ SUMP ❑ GRINDER fl NON -CLOG MODEL' H'(DROMATIC BV40 DISCHARGE PIPE ❑ SCH,40 GALVANIZED ❑ SCH.80 PVC ❑ 304 STAINLESS STEEL DIAMETER: GUIDE RAILS: ❑ GALVANIZED ❑ 304 STAINLESS STEEL COVER SPECIFICATIONS ❑ STEEL HINGED DOOR 11 ALUMINUM HINGED DOOR ❑ FRP HINGED DOOR ❑ SOLID FIBERGLASS 02' VENT ON COVER IER GUIDE RAIL BRACKET GREEN MUSHROOM VENT CAP `,LIFTING LUGS (ON DUPLEX UNITS ONLY) SS EXTENSION /--HANDLES AND BRACKETS /-(2) GATE VALVES ,-(I) TEE IINV. ELEV, FIELD VERIFY ELEVATION `S.S, DISCH. COUPLING �(2> ELBOWS "'-(2) BALL CHECK VALVES "�-(3) UNIONS x-3/4' GUIDE RAILS -DISCHARGE PIPING .J(2) COUPLINGS r-(2) EZ -OUT BASES ANTI FLOAT FOR SUBMITTAL USE ONLY. NOT A PRODUCTI❑N DRAWING DATE POI DRAWN FOR 02/04/2000 -- DRAWN EM SHEET 1 OF 1 DESCRIPTION OVO. M G. BAUER ALL UNITS ARE IN INCHES DUPLEX EZ -OUT SYSTEM 0001 REV. x 02 GUIK RAIL (NOT INCLUDED) kas s U.S. PAltNT 5,$07,628 .,. ,_ RAIL x. .., / PARTS 4PENTAIR HYDROMATIC Pentair Electronic Catalog Hydromatic \ Pentair Water • 293 Wright Street • Delavan, Wisconsin 53115 phone: (888)957-8677 • fax: (800)426-9446 • www.hyrdomaticresidential.com Pump Performance Datasheet Customer Quote number Customer reference Size : BV40 Item number : Default Stages : 1 Service Based on curve number : SSE0019 Quantity : 1 Date last saved : 09 Apr 2014 12:59 PM Operating Conditions Liquid Flow, rated :60.00 USgpm Liquid type : --Water Differential head / pressure, rated (requested) : 6.00 ft Additional liquid description Differential head / pressure, rated (actual) : 6.82 ft Solids diameter, max : 0.00 in Suction pressure, rated / max : 0.00 / 0.00 psi.g Solids concentration, by volume : 0.00 % NPSH available, rated : Ample Temperature, max : 68.00 deg F Frequency : 60 Hz Fluid density, rated / max : 1.000 / 1.000 SG Performance Viscosity, rated : 1.00 cP Speed, rated : 1,550 rpm Vapor pressure, rated : 0.00 psi.a Impeller diameter, rated : 5.24 in Impeller diameter, maximum : 5.24 in Material selected : Standard Impeller diameter, minimum : 5.24 in Pressure Data Efficiency Maximum working pressure : 7.72 psi.g NPSH required / margin required : - / 0.00 ft Maximum allowable working pressure : N/A nq (imp. eye flow) / S (imp. eye flow) : N/A Metric units Maximum allowable suction pressure : N/A MCSF : 11.13 USgpm Hydrostatic test pressure : N/A Head, maximum, rated diameter : 17.83 ft Driver & Power Data Head rise to shutoff : 161.65% Driver sizing specification : Rated power Flow, best eff. point (BEP) - Margin over specification : 0.00 % Flow ratio (rated / BEP) Service factor :1.00 Diameter ratio (rated / max) :100.00 % Power, hydraulic : 0.10 hp Head ratio (rated dia / max dia) : 100.00% Power, rated : 0.40 hp Cq/Ch/Ce/Cn [ANSI/HI 9.6.7-2010] :1.00 / 1.00 / 1.00 / 1.00 Power, maximum, rated diameter : 0.40 hp Selection status : Acceptable Minimum recommended motor rating : 0.40 hp / 0.30 kW (Fixed) 0.6 0.45 a t Power 3 0.3 0 a 0.15- 0 20 MCSF 18 5.24 in 16 14 12 c @ 10 d x 8 6 4 2 - 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Flow - USgpm Hydromatic \ Pentair Water • 293 Wright Street • Delavan, Wisconsin 53115 phone: (888)957-8677 • fax: (800)426-9446 • www.hyrdomaticresidential.com SEWAGE PUMPS Recessed vortex impeller allows pumping of stringy material and reduces clogging Typical Application Sewage, dewatering Capacities up to 77 GPM (4.8 LPS) Heads up to 19 ft. (5.8 m) Electrical 115V, id, 12.6 FLA, 60Hz Motor (single phase) 4/10 HP split phase w/thermal overload protection Intermittent Liquid Temperature 120°F(49°C) Minimum Recommended Sump Diameter 18" (457.2 mm) Automatic Operation BV40AW1 = Wide-angle float switch BV40AD1= Diaphragm pressure switch Materials of Construction Cast iron & engineered thermoplastic Impeller Engineered thermoplastic Discharge Size 2" NPT (50.8 mm) std. Solids Handling 2" (50.8 mm) Power Cord 10'/20' std.,18/3, SJTW BV40Aw1 Wide -Angle Float Switch BV40AD1 Diaphragm Pressure Switch Carbon/Ceramic type 21 mechanical seal piggyback Switch Plug Oil -filled motor w/automatic reset thermal overload for maximum protection Lower single -row ball-bearing construction Piggyback plug available for easy maintenance and switch replacement 25 2 1 1 = 0 US GPM 20 40 60 80 100 I'rlj?o HYDROMATIC" USA Wholesale/Residential Products• 888-957-8677.Orders Fax: 800-426-9446 Canada Kitchener, Ontario • 519-896-2163.Orders Fax: 519-896-6337 www.hydromatic.com HYD10168 Rev12/10 BV40 5 0 = 0 US GPM 20 40 60 80 100 I'rlj?o HYDROMATIC" USA Wholesale/Residential Products• 888-957-8677.Orders Fax: 800-426-9446 Canada Kitchener, Ontario • 519-896-2163.Orders Fax: 519-896-6337 www.hydromatic.com HYD10168 Rev12/10 Wholesale Products Page: 7140-1 Dated: August 200� Supersedes: May 2002 RPM: 1550 Discharge: 2" SoLids: 2" Capacity -U.S. G.P.M. Liters/Second O 1 2 3 4 5 Liters/Second The curves reftect maximum performance characteristics without exceeding huK toad (Namepta»e) horsepower. 4U pumps have a service factor of 1.2. Operation is recommended in the bounded area with operahvnai point within the curve Limit. Performance curves are based onactuaitestswithc\earwmterat78°F.and 1280feet site e&v hon. Conditions n(Service: 25 7 20 5 LU LL 15 � 4 5� � 1O 3 Capacity -U.S. G.P.M. Liters/Second O 1 2 3 4 5 Liters/Second The curves reftect maximum performance characteristics without exceeding huK toad (Namepta»e) horsepower. 4U pumps have a service factor of 1.2. Operation is recommended in the bounded area with operahvnai point within the curve Limit. Performance curves are based onactuaitestswithc\earwmterat78°F.and 1280feet site e&v hon. Conditions n(Service: Whotesale Products Page: 1 Dated: August11 Supersedes: 0 All dimensions in inches. Metric for international use. Component dimensions may vary ± 1/8 inch. Dimensional data not for construction purpose unless certified. Dimensions and weights are approximate. On/Off level adjustable. We reserve the right to make revisions to our product Is) and the product (s) specifications without notice. Diaphragm Switch On = V/e" Off = 41/4" 139/,6° (344.49) DISCHARGE Vertical Switch 13" HEIGHT On = 815/,6" (330.2) p 1. Off = 4'/,6" 67 (1555.57 Wide Angle Switch On = 121/2" Off = 61/42" (87) _(120) 1 139/,6" (344.49)o t ° 'I(.315/16" (99) DISCHARGE 13" HEIGHT (330.2) 3(80) 61/a" b (155.57 All dimensions in inches. Metric for international use. Component dimensions may vary ± 1/8 inch. Dimensional data not for construction purpose unless certified. Dimensions and weights are approximate. On/Off level adjustable. We reserve the right to make revisions to our product Is) and the product (s) specifications without notice. <4 Y Wholesale Products Par Dated- May 201 MOTOR TYPE OIL FILLED, SPLIT PHASE W ITH THERMAL OVERLOAD HP VOLTAGE PHASE NEC CODE SERVICE FACTOR FULL LOAD AMPS 4/10 115 1 1 • F14 IMVIw YAPhysical Data - 11 1 1 11 11 � vi�. DISCHARGE SIZE 2" NPT SOLIDS SIZE 2" IMPELLER TYPE RECESSED VORTEX CABLE LENGTH 10' STANDARD 20' OPTIONAL PAINT PAINTED AFTER ASSEMBLY, DARK GREEN, WATER REDUCIBLE ENAMEL, ONE COAT, AIR DRIED. MAXIMUM LIQUID 120°F MAXIMUM STATOR - OIL FLASH POINT - POWER CORD TYPE SJTW VOLUTE THERMOPLASTIC MOTOR HOUSING CAST IRON LL z 02 (BEARING/ CAST IRON Q U SEAL HOUSING) wIMPELLER THERMOPLASTIC O MOTOR SHAFT STEEL 0 HARDWARE STAINLESS STEEL "0" RINGS BUNA-N MECHANICAL SEALS Standard: CARBON / CERAMIC UPPER BEARING BRONZE SLEEVE LOWER BEARING SINGLE ROW -BALL ME 1-1 =� W Contractor shalt furnish all labor, materials, equipment and incidentals required to provide (Oty.) submersible centrifugal non clog sewage pumps) as specified herein. The pump model covered in this specification is the BV -40. The pump furnished for this application shall be MODEL as manufactured by Hydromatic Pumps. 2.01 DESIGN CONDITIONS Each pump shall be rated H. P., volts, phase, hertz and operate at RPM. [tI17�ti1:7�r7__�iI►Cc7�Ti7.1]�iC�l� The pump shall deliver U.S. GPM/LPS at feet/meters TDH, and handle a inch solid. The curve submitted for approval shall state, in addition to head and capacity performance, solid handling capability, amp rating, and design impeller diameter. Each pump shall be of the sealed submersible type, incorporating features normally found in pumps furnished for the heavy duty industrial or municipal markets. These features include: 1. The pump, motor, and seat housing shall be high quality gray cast iron, ASTM A-48, Class 30. The pump volute for the BV -40 is corrosion resistant high density thermoplastic. 2. The pump inlet shall be open and clear, without screening to provide access for sewage and solids. 3. All external mating parts shalt be machined and Buna N, 0 -Ring sealed. 4. All fasteners exposed to the pumped liquid shall be 300 series stainless steel. 5. All power cords shalt be water resistant UL or CSA approved, with double insulation, and sized as a function of Amp. draw. The stator, rotor and bearings shall be mounted in a seated submersible type housing. Single phase motors shalt be split phase or capacitor start with centrifugal switch. Full Load and Locked Rotor Amps as well as Start and Run winding resistance shalt be tabulated for each pump. An upper radial and tower thrust bearing shall be required. The upper baring is a bronze sleeve type and the tower baring shall be heavy duty single row ball bearings which are permanently and continuously lubricated and cooled by the dielectric oil which fills the motor housing. The motor shaft shall be stainless steel and sealed from the pumped liquid with a carbon ceramic mechanical seal. Ml � T01 IMPELLER The Impeller shalt be high capacity, eight vane, non clog design with pump out vanes on the back side. These vanes wash out grit and stringy material that wilt damage the shaft and mechanical seal. All single phase pumps should be capable of automatic operation. The BV -40 pump is furnished with a pressure diaphragm switch that features a piggy -back plug that allows the pump to be operated manually without removal from the sump. 11 � The BV -40 pump is supplied with a tilt -sensitive wide-angle float switch is seated in a non -corrosive PVC enclosure. The unit is UL listed for water and sewage and CSA certified. The float switch shall also be fitted with a piggy -back plug that allows the pump to be operated manually without removal from the sump. All cast iron parts shall be painted before assembly with a water reducible alkyd air dried enamel. The paint shall be applied in one coat with a minimum thickness of 3 to 4 mils. 12.01 TESTING All pumps shall be individually tested to include the following: 1. The pump and power cord shalt be visually inspected for imperfections, cuts or nicks. 2. The pump shall have a ground continuity check and the motor chamber shalt be Hi -potted to test for moisture content and/or insulation defects. 3. The motor and volute housing shall be pressurized and a 10 second air leak decay test run. 4. Oil is added, and the pump is run. Voltage and current are monitored visually, electronically, and the tester listens for any noise or malfunction. 8= USA CANADA 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.HYDROMATIC.COM 269 TRILLIUM DRIVE, KITCHENER, ONTARIO, CANADA N2G 4W5 PH: 888-957-8677 ORDERS FAX: 800-426-9446 PH: 519-896-2163 ORDERS FAX: 519-896-6337 Because we are continuously improving our products and services, Pentair reserves the richt to change specifications without prior notice. © 2013 Pentair Ltd. Atl Rights Resrved. W--260 ,0�q( li 3