HomeMy WebLinkAboutPLANS - Parapet & Roof - 18-00284 - Rexburg Temple - RemodelNexus Project #:Owner Project #:50007516020101
THE CHURCH OF JESUS
CHRIST OF LATTER DAY
SAINTS
Rexburg Idaho
Temple Parapet
& Roof
7TH SOUTH 2ND EAST
REXBURG, IDAHO
Construction Documentation
05.11.18
14134.02
[STAMP]
CONTACT:E-MAIL:
PHONE:INTERNET:
[LOGO]OWNER
THE CHURCH OF JESUS CHRIST OF LATTER DAY SAINTS
50 East North Temple
Salt Lake City, Utah 84150
801.240.0086
COREY DANIELS COREYDANIELS@LDS.ORG
.
CONTACT:E-MAIL:
PHONE:INTERNET:
ARCHITECT
Architectural NEXUS, Inc.
2505 East Parleys Way
Salt Lake City, UT 84109
801.924.5000
xxxxxx BPETROFF@archnexus.com
http://www.archnexus.com
[STAMP]
CONTACT:E-MAIL:
PHONE:INTERNET:
[LOGO]BUILDING ENVELOPE CONSULTANT
MORRISON HERSHFIELD
50 West Broadway, Suite 300,
Salt Lake City, UT 84101
801.833.8344
xxxxx RZiegler@morrisonhershfield.com
morrison hershfield.com
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
Architectural NEXUS, Inc.
2505 East Parleys Way
Salt Lake City, Utah 84109
T 801.924.5000
http://www.archnexus.com
654321
E
D
C
B
A
PE
R
M
I
T
S
E
T
OW
N
E
R
P
R
O
J
E
C
T
N
U
M
B
E
R
:
5
0
0
0
7
5
1
6
0
2
0
1
0
1
5/
1
8
/
2
0
1
8
8
:
2
1
:
4
5
A
M
COVER SHEET
NLS
7T
H
S
O
U
T
H
2
N
D
E
A
S
T
R
E
X
B
U
R
G
,
I
D
A
H
O
TH
E
C
H
U
R
C
H
O
F
J
E
S
U
S
C
H
R
I
S
T
O
F
L
A
T
T
E
R
D
A
Y
S
A
I
N
T
S
14134.02
05.11.18
Re
x
b
u
r
g
I
d
a
h
o
T
e
m
p
l
e
P
a
r
a
p
e
t
&
R
o
o
f
Construction
Documentation
G001
BP
# Date Revision
MATCH LINE
SEE A2222
MATCH LINE TAG
EXISTING WALL TO REMAIN
WALL TO BE DEMOLISHED
NEW WALL
BREAK LINE
CENTER LINE SYMBOL
0' 4' 8' 16'
REVISION DESIGNATION
ELEVATION SYMBOL
1
T.O. WALL
100'-0"
REVISION NUMBER
ELEVATION ABOVE DATUM
ELEVATION DESCRIPTION
DRAWING SYMBOL LEGEND
000M
CASEWORK TYPE DESIGNATION
CDS NUMBER (M DENOTES
MODIFICATION -SEE SHEET
A551 FOR MODIFIED MILLWORK
ELEVATIONS AND DETAILS)
00"
00"
00"
MODIFICATION DESCRIPTION
AWS STANDARD CDS NUMBERING SYSTEM
WIDTH
HEIGHT
DEPTH
NORTH ARROW
PLAN NORTH
GRAPHIC SCALES
ROUND BREAK LINE
REVISION CLOUD
SLOPE INDICATION
1/2" / 12"
DETAIL REFERENCE
A2 A401
A1
A3 INTERIOR ELEVATIONS
DETAIL NUMBER
SHEET NUMBER
A1
A501
DETAIL REFERENCE
DETAIL NUMBER
SHEET NUMBER
A1
A201
EXTERIOR ELEVATION REFERENCE
SHEET NUMBER
DETAIL NUMBER
A1
A302
WALL SECTION REFERENCE
SHEET NUMBER
DETAIL NUMBER
A1
A301
BUILDING SECTION REFERENCE
DETAIL NUMBER
SHEET NUMBER
XX000X
00'-00"
ROOM DESIGNATION (FLOOR PLAN)
ROOM NUMBER
ROOM NAME
A1
A301
DETAIL NUMBER
SHEET NUMBER
ROOM DESIGNATION (REFLECTED
CEILING PLAN)
CEILING HEIGHT ABOVE FINISH FLOOR
ROOM NUMBER
00001
A
1
GLASS TYPE DESIGNATION
KEYED NOTE DESIGNATION
WALL TYPE DESIGNATION
EQUIPMENT DESIGNATION
WINDOW DESIGNATION
DOOR DESIGNATION
GLASS TYPE
EQUIPMENT NUMBER
KEY NOTE NUMBER
WINDOW TYPE
DOOR NUMBER
WALL TYPE
101
XXX
N
MATERIAL TYPE DESIGNATION
FINISH NUMBER
SEE AI601 FINISH LEGEND
00001
12"
1/2
"
RISE
RUN
TRUE NORTH
CL
03:CJ1
####
ROOM
LIST OF ABBREVIATIONS
THE PRECEDING LIST OF ABBREVIATIONS
IS PRESENTED AS A GENERAL GUIDE AND
DOES NOT NECESSARILY SHOW ALL
ABBREVIATIONS USED. OTHER
GENERALLY ACCEPTED ABBREVIATIONS
MAY BE FOUND AMONG THE DRAWINGS -
SOME ABBREVIATIONS SHOWN ABOVE
MAY NOT BE USED WITHIN THIS DRAWING
SET.
A
A/C AIR CONDITIONING
AD AREA DRAIN
AFC ABOVE FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ALUM ALUMINUM
ANOD ANODIZED
ARCH ARCHITECT
@ AT
B
BD BOARD
BLDG BUILDING
BO BOTTOM OF
C
C CELSIUS
CH COAT HOOK
CFCI CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CG CORNER GUARD
CI CONTINUOUS INSULATION
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
CT CERAMIC TILE
CTJ CONSTRUCTION JOINT
CUH CABINET UNIT HEATER
D
D DEEP
DEG DEGREE
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DN DOWN
DS DOWNSPOUT
DWGS DRAWINGS
E
EA EACH
EJ EXPANSION JOINT
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EOS EDGE OF SLAB
ERD EXISTING ROOF DRAIN
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
F
F FAHRENHEIT
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FDC FIRE DEPARTMENT CONNECTION
FD FLOOR DRAIN
FEC FIRE EXTINGUISHER CABINET
FE FIRE EXTINGUISHER
FG FINISH GRADE
FHC FIRE HOSE CABINET
FIN FINISH
FLR FLOOR
FND FOUNDATION
FO FINISHED OPENING
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FOS FACE OF STUD
FOW FACE OF WALL
FRG FIBER REINFORCED GYPSUM
FSP FIRE STANDPIPE
FT FEET
FV FIELD VERIFY
G
GA GAUGE
GALV GALVANIZED
GFRC GLASS-FIBER-REINFORCED
CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GL GLASS
GWB GYPSUM WALL BOARD
GYP GYPSUM
H
H HIGH
HB HOSE BIBB
HDR HEADER
HM HOLLOW METAL
HPT HIGH POINT
HR HOUR
HT HEIGHT
I
ID INSIDE DIAMETER; INSIDE DIMENSION
IN INCH
INFO INFORMATION
INT INTERIOR
J
JAN JANITOR
K (NOT USED)
L
LAB LABORATORY
LAV LAVATORY
LBS POUNDS
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LPT LOW POINT
M
MACH RM MACHINE ROOM
MAX MAXIMUM
MFR MANUFACTURER
MECH MECHANICAL
MEZZ MEZZANINE
MIN MINIMUM
MO MASONRY OPENING
N
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
O
OC ON CENTER
OD OUTSIDE DIAMETER;
OUTSIDE DIMENSION
OFD OVERFLOW DRAIN
OH DR OVERHEAD DOOR
OPH OPPOSITE HAND
OPP OPPOSITE
ORIG ORIGINAL
P
P LAM PLASTIC LAMINATE
PLAS PLASTER
PLUMB PLUMBING
PR PAIR
PSI POUNDS PER SQUARE INCH
PSF POUNDS PER SQUARE FOOT
PVC POLYVINYL CHLORIDE
Q
QT QUARRY TILE
R
R RISER OR RADIUS
RAD RADIUS
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFRIDGERATOR
REQD REQUIRED
REV REVISION
RH RELATIVE HUMIDITY
RM ROOM
RO ROUGH OPENING
RTU ROOF TOP UNIT
RWL RAIN WATER LEADER
S
S SMOKE DETECTOR
SAM SELF ADHESIVE MEMBRANE
SCHED SCHEDULE
SECT SECTION
SIM SIMILAR
SPEC SPECIFICATION
SS STAINLESS STEEL
STD STANDARD
STRUCT STRUCTURAL
T
T TREAD
TEL TELEPHONE
TEMP TEMPORARY
THK THICK
TOC TOP OF CONCRETE
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF SLAB; TOP OF STEEL
TOW TOP OF WALL
TYP TYPICAL
TO TOP OF
U
UL UNDERWRITER'S LABORATORIES
UNO UNLESS NOTED OTHERWISE
V
VCT VINYL COMPOSITE TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
W
W/WITH
W/O WITHOUT
WD WOOD
WH WALL HYDRANT
WP WORKING POINT
WRB WEATHER RESISTIVE BARRIER
WIC WORK IN CONTRACT
X,Y,Z (NOT USED)
CAST-IN-PLACE CONCRETE
CONCRETE MASONRY UNIT
PRECAST CONCRETE / GLASS FIBER
REINFORCED CONCRETE (GFRC)
STEEL STUDS
WOOD STUDS
BRICK VENEER
RIGID INSULATION
BATT INSULATION
CONTINUOUS MATERIAL
NON CONTINUOUS MATERIAL
(BLOCKING)
GYPSUM BOARD
PLYWOOD
GRAVEL
UNDISTURBED EARTH
HATCH LEGEND
NOTE: HATCHING ANGLES MAY VARY DUE TO ANGLE OF WALL DRAWN, WHILE HATCHING PATTERN REMAINS SIMILAR.
BACKFILL OR FILL
EXTERIOR SHEATHING
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
Architectural NEXUS, Inc.
2505 East Parleys Way
Salt Lake City, Utah 84109
T 801.924.5000
http://www.archnexus.com
654321
E
D
C
B
A
PE
R
M
I
T
S
E
T
OW
N
E
R
P
R
O
J
E
C
T
N
U
M
B
E
R
:
5
0
0
0
7
5
1
6
0
2
0
1
0
1
5/
1
8
/
2
0
1
8
8
:
2
1
:
5
1
A
M
GENERAL
INFORMATION
NLS
7T
H
S
O
U
T
H
2
N
D
E
A
S
T
R
E
X
B
U
R
G
,
I
D
A
H
O
TH
E
C
H
U
R
C
H
O
F
J
E
S
U
S
C
H
R
I
S
T
O
F
L
A
T
T
E
R
D
A
Y
S
A
I
N
T
S
14134.02
05.11.18
Re
x
b
u
r
g
I
d
a
h
o
T
e
m
p
l
e
P
a
r
a
p
e
t
&
R
o
o
f
Construction
Documentation
G002
BP
APPROVALS
Signer 1 Date
Signer 2 Date
Signer 3 Date
Signer 4 Date
INTERNATIONAL PLUMBING CODE
NATIONAL ELECTRICAL CODE
ZONING ORDINANCE:
INTERNATIONAL MECHANICAL CODE
INTERNATIONAL FIRE CODE
INTERNATIONAL ENERGY CONSERVATION CODE
INTERNATIONAL BUILDING CODE
ACCESSIBILITY CODE
DESIGN CRITERIA
APPLICABLE CODES OTHER CRITERIA
DEFERRED SUBMITTALS
OCCUPANCY CLASSIFICATION
EXISTING BUILDING TYPE I-B
A3
ICC/ANSI A117.1-2009
2015 EDITION
2015 EDITION
2015 EDITION
2015 EDITION
2015 EDITION
2014 EDITION
Zoning Ordinance. . . Enter City . . .
SHEET INDEX
GENERAL:
G001 COVER SHEET
G002 GENERAL INFORMATION
G003 GENERAL INFORMATION
ARCHITECTURAL:
AD121 DEMOLITION ROOF PLAN
AD122 DEMOLITION MECHANICAL LEVEL AND TOWER ROOF PLANS
A121 ROOF PLAN
A122 MECHANICAL LEVEL AND TOWER ROOF PLANS
A521 ARCHITECTURAL ROOF DETAILS
A522 ARCHITECTURAL ROOF DETAILS
A523 ARCHITECTURAL ROOF DETAILS
ELECTRICAL:
L - 9.3 SECOND LEVEL EXTERIOR LIGHTING PLAN (FOR REFRENCE ONLY)
L - 9.6 ROOF LIGHTING PLAN (FOR REFRENCE ONLY)
LOCATION
# Date Revision
MATCH LINE
SEE A2222
MATCH LINE TAG
EXISTING WALL TO REMAIN
WALL TO BE DEMOLISHED
NEW WALL
BREAK LINE
CENTER LINE SYMBOL
0' 4' 8' 16'
REVISION DESIGNATION
ELEVATION SYMBOL
1
T.O. WALL
100'-0"
REVISION NUMBER
ELEVATION ABOVE DATUM
ELEVATION DESCRIPTION
DRAWING SYMBOL LEGEND
000M
CASEWORK TYPE DESIGNATION
CDS NUMBER (M DENOTES
MODIFICATION -SEE SHEET
A551 FOR MODIFIED MILLWORK
ELEVATIONS AND DETAILS)
00"
00"
00"
MODIFICATION DESCRIPTION
AWS STANDARD CDS NUMBERING SYSTEM
WIDTH
HEIGHT
DEPTH
NORTH ARROW
PLAN NORTH
GRAPHIC SCALES
ROUND BREAK LINE
REVISION CLOUD
SLOPE INDICATION
1/2" / 12"
DETAIL REFERENCE
A2 A401
A1
A3 INTERIOR ELEVATIONS
DETAIL NUMBER
SHEET NUMBER
A1
A501
DETAIL REFERENCE
DETAIL NUMBER
SHEET NUMBER
A1
A201
EXTERIOR ELEVATION REFERENCE
SHEET NUMBER
DETAIL NUMBER
A1
A302
WALL SECTION REFERENCE
SHEET NUMBER
DETAIL NUMBER
A1
A301
BUILDING SECTION REFERENCE
DETAIL NUMBER
SHEET NUMBER
XX000X
00'-00"
ROOM DESIGNATION (FLOOR PLAN)
ROOM NUMBER
ROOM NAME
A1
A301
DETAIL NUMBER
SHEET NUMBER
ROOM DESIGNATION (REFLECTED
CEILING PLAN)
CEILING HEIGHT ABOVE FINISH FLOOR
ROOM NUMBER
00001
A
1
GLASS TYPE DESIGNATION
KEYED NOTE DESIGNATION
WALL TYPE DESIGNATION
EQUIPMENT DESIGNATION
WINDOW DESIGNATION
DOOR DESIGNATION
GLASS TYPE
EQUIPMENT NUMBER
KEY NOTE NUMBER
WINDOW TYPE
DOOR NUMBER
WALL TYPE
101
XXX
N
MATERIAL TYPE DESIGNATION
FINISH NUMBER
SEE AI601 FINISH LEGEND
00001
12"
1/2
"
RISE
RUN
TRUE NORTH
CL
03:CJ1
####
ROOM
CAST-IN-PLACE CONCRETE
CONCRETE MASONRY UNIT
PRECAST CONCRETE / GLASS FIBER
REINFORCED CONCRETE (GFRC)
STEEL STUDS
WOOD STUDS
BRICK VENEER
RIGID INSULATION
BATT INSULATION
CONTINUOUS MATERIAL
NON CONTINUOUS MATERIAL
(BLOCKING)
GYPSUM BOARD
PLYWOOD
GRAVEL
UNDISTURBED EARTH
HATCH LEGEND
NOTE: HATCHING ANGLES MAY VARY DUE TO ANGLE OF WALL DRAWN, WHILE HATCHING PATTERN REMAINS SIMILAR.
BACKFILL OR FILL
EXTERIOR SHEATHING
LIST OF ABBREVIATIONS
THE PRECEDING LIST OF ABBREVIATIONS
IS PRESENTED AS A GENERAL GUIDE AND
DOES NOT NECESSARILY SHOW ALL
ABBREVIATIONS USED. OTHER
GENERALLY ACCEPTED ABBREVIATIONS
MAY BE FOUND AMONG THE DRAWINGS -
SOME ABBREVIATIONS SHOWN ABOVE
MAY NOT BE USED WITHIN THIS DRAWING
SET.
A
A/C AIR CONDITIONING
AD AREA DRAIN
AFC ABOVE FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ALUM ALUMINUM
ANOD ANODIZED
ARCH ARCHITECT
@ AT
B
BD BOARD
BLDG BUILDING
BO BOTTOM OF
C
C CELSIUS
CH COAT HOOK
CFCI CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CG CORNER GUARD
CI CONTINUOUS INSULATION
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
CT CERAMIC TILE
CTJ CONSTRUCTION JOINT
CUH CABINET UNIT HEATER
D
D DEEP
DEG DEGREE
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DN DOWN
DS DOWNSPOUT
DWGS DRAWINGS
E
EA EACH
EJ EXPANSION JOINT
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EOS EDGE OF SLAB
ERD EXISTING ROOF DRAIN
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
F
F FAHRENHEIT
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FDC FIRE DEPARTMENT CONNECTION
FD FLOOR DRAIN
FEC FIRE EXTINGUISHER CABINET
FE FIRE EXTINGUISHER
FG FINISH GRADE
FHC FIRE HOSE CABINET
FIN FINISH
FLR FLOOR
FND FOUNDATION
FO FINISHED OPENING
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FOS FACE OF STUD
FOW FACE OF WALL
FRG FIBER REINFORCED GYPSUM
FSP FIRE STANDPIPE
FT FEET
FV FIELD VERIFY
G
GA GAUGE
GALV GALVANIZED
GFRC GLASS-FIBER-REINFORCED
CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GL GLASS
GWB GYPSUM WALL BOARD
GYP GYPSUM
H
H HIGH
HB HOSE BIBB
HDR HEADER
HM HOLLOW METAL
HPT HIGH POINT
HR HOUR
HT HEIGHT
I
ID INSIDE DIAMETER; INSIDE DIMENSION
IN INCH
INFO INFORMATION
INT INTERIOR
J
JAN JANITOR
K (NOT USED)
L
LAB LABORATORY
LAV LAVATORY
LBS POUNDS
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LPT LOW POINT
M
MACH RM MACHINE ROOM
MAX MAXIMUM
MFR MANUFACTURER
MECH MECHANICAL
MEZZ MEZZANINE
MIN MINIMUM
MO MASONRY OPENING
N
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
O
OC ON CENTER
OD OUTSIDE DIAMETER;
OUTSIDE DIMENSION
OFD OVERFLOW DRAIN
OH DR OVERHEAD DOOR
OPH OPPOSITE HAND
OPP OPPOSITE
ORIG ORIGINAL
P
P LAM PLASTIC LAMINATE
PLAS PLASTER
PLUMB PLUMBING
PR PAIR
PSI POUNDS PER SQUARE INCH
PSF POUNDS PER SQUARE FOOT
PVC POLYVINYL CHLORIDE
Q
QT QUARRY TILE
R
R RISER OR RADIUS
RAD RADIUS
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFRIDGERATOR
REQD REQUIRED
REV REVISION
RH RELATIVE HUMIDITY
RM ROOM
RO ROUGH OPENING
RTU ROOF TOP UNIT
RWL RAIN WATER LEADER
S
S SMOKE DETECTOR
SAM SELF ADHESIVE MEMBRANE
SCHED SCHEDULE
SECT SECTION
SIM SIMILAR
SPEC SPECIFICATION
SS STAINLESS STEEL
STD STANDARD
STRUCT STRUCTURAL
T
T TREAD
TEL TELEPHONE
TEMP TEMPORARY
THK THICK
TOC TOP OF CONCRETE
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF SLAB; TOP OF STEEL
TOW TOP OF WALL
TYP TYPICAL
TO TOP OF
U
UL UNDERWRITER'S LABORATORIES
UNO UNLESS NOTED OTHERWISE
V
VCT VINYL COMPOSITE TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
W
W/WITH
W/O WITHOUT
WD WOOD
WH WALL HYDRANT
WP WORKING POINT
WRB WEATHER RESISTIVE BARRIER
WIC WORK IN CONTRACT
X,Y,Z (NOT USED)
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
Architectural NEXUS, Inc.
2505 East Parleys Way
Salt Lake City, Utah 84109
T 801.924.5000
http://www.archnexus.com
654321
E
D
C
B
A
PE
R
M
I
T
S
E
T
OW
N
E
R
P
R
O
J
E
C
T
N
U
M
B
E
R
:
5
0
0
0
7
5
1
6
0
2
0
1
0
1
5/
1
8
/
2
0
1
8
8
:
2
1
:
5
2
A
M
GENERAL
INFORMATION
NLS
7T
H
S
O
U
T
H
2
N
D
E
A
S
T
R
E
X
B
U
R
G
,
I
D
A
H
O
TH
E
C
H
U
R
C
H
O
F
J
E
S
U
S
C
H
R
I
S
T
O
F
L
A
T
T
E
R
D
A
Y
S
A
I
N
T
S
14134.02
05.11.18
Re
x
b
u
r
g
I
d
a
h
o
T
e
m
p
l
e
P
a
r
a
p
e
t
&
R
o
o
f
Construction
Documentation
G003
BP
# Date Revision
A. ALL INDICATED ROOF PARAPETS TO BE REMOVED & REPAIRED
PER ARCHITECTURAL ROOF DETAILS.
B. REMOVE, PRESERVE AND REINSTALL ANY ROOF TOP DEVICES
AS NEEDED TO REPAIR ROOF AND PARAPETS.
C. REMOVE & SALVAGE EXISTING ROOF & WALL MOUNTED
EXTERIOR LIGHTING AS REQUIRED FOR NEW WORK. THIS
INCLUDES CONDUITS, J-BOXES, MOUNTING PADS, ETC.
COORDINATE EXTENT WITH OTHER SUB-CONTRACTORS & G.C.
D. SEE REFERENCE DRAWINGS L-9.3& L-9.6 SHOWING
APPROXIMATE LOCATION OF EXISTING LIGHTING FIELD VERIFY
EXTENT OF WORK BEFORE BIDDING.CONTRACTOR WILL BE
RESPONSIBLE FOR REMOVING & REINSTALL ALL EXISTING
LIGHTING, J-BOXES, MOUNTING PADS, CONDUIT, ETC. EVEN IF
NOT IDENTIFIED SPECIFICALLY IN THESE DOCUMENTS.
E. CONTRACTOR TO DOCUMENT LOCATION OF EXISTING LIGHTS
FIXTURES, CONDUITS, AND LIGHT PEDESTALS BEFORE
REMOVAL OF LIGHTS, ETC. CONTRACTOR TO PROVIDE PLAN
WITH LIGHT LOCATIONS WITH DIMENSIONS TO OWNER &
ARCHITECT FOR DOCUMENTATION. LIGHTS, PEDESTAL ETC. TO
BE REINSTALLED IN EXACT LOCATION AFTER INSTALLATION OF
NEW ROOF SYSTEM.
F. THE CONTRACTOR IS RESPONSIBLE FOR ALL MATERIAL BEING
REMOVED & SALVAGED FOR REUSE. ANY NEW MATERIAL
REQUIRED TO REPLACE ANY NON SALVAGEABLE MATERIALS
SHALL BE INCLUDED IN THE CONTRACTOR'S SCOPE OF WORK.
G. ALL ROOFS SHALL HAVE A MINIMUM 1/4" TO 12" SLOPE
H. PROVIDE NEW FLASHING AROUND ALL EXISTING AND NEW
ROOF PENETRATIONS AS APPROVED BY ROOF
MANUFACTURER, i.e.: PIPE VENTS, CONDUIT, LIGHT PEDESTALS,
ETC.
GENERAL NOTE -ROOF PLAN
RID
G
E
RID
G
E
RIDGE
RIDGE
D1
A521
D1
A521
A3
A521
B4
A522
B4
A522
D1
A522
D1
A522
A1
A521
A1
A521
B4
A522
B4
A522
A3
A521
B3
A523
B3
A523
B3
A523
B3
A523
D1
A522
D1
A522
37
'
-
3
"
+
/
-
33
'
-
1
1
"
+
/
-
40' - 4" +/-
20' - 6" +/-
21
'
-
4
"
+
O
R
-
46' - 5" +/-
103' - 9" +/-
2'
-
8
"
21
'
-
6
"
+
/
-
4' - 0" +/-
A3
A521
A3
A521
B4
A522
B4
A522
B4
A522
B4
A522
B3
A523
B3
A523
SIM.SIM.
12 2
12 2
1
2
1
2
1
2
1
2
TOP OF PARAPET
111' - 7"
TOP OF DRAIN
111' - 4 1/2"
TOP OF COLUMN
115' - 10"
TOP OF PARAPET
119' - 2"
TOP OF COLUMN
115' - 10"
TOP OF DRAIN
111' - 4 1/2"
TOP OF PARAPET
111' - 7"
TOP OF DRAIN
111' - 4 1/2"
TOP OF DRAIN
111' - 4 1/2"
TOP OF DRAIN
115' - 7"
TOP OF PARAPET
117' - 0"
TOP OF DRAIN
115' - 7"
TOP OF PARAPET
117' - 0"
TOP OF DRAIN
115' - 7"
TOP OF PARAPET
117' - 0"
TOP OF DRAIN
115' - 1"
TOP OF DRAIN
115' - 1"
TOP OF PARAPET
117' - 0"
TOP OF DRAIN
115' - 1"
TOP OF DRAIN
115' - 1"
TOP OF PARAPET
95' - 7"
TOP OF DRAIN
95' - 4 1/2"
TOP OF PARAPET
94' - 2"
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
2
1
2
1
RID
G
E
RID
G
E
A1
A521
A1
A521
A1
A521
A1
A521
A1
A521
3
A523
A1
A521
A1
A521
A4
A523A4
A523
A4
A523
A4
A523
105' - 5" +/-
25' - 6" +/-
11
'
-
8
"
+
/
-
9'
-
1
"
24
'
-
1
1
"
+
/
-
6' - 9" +/-
7' - 7" +/-
7'
-
4
"
2'
-
7
"
+
/
-
3
A523
A1
A521
A1
A521
A1
A521
A1
A521
A1
A521
A1
A521
A1
A521
A1
A521
A1
A521
A1
A521
12
1 1
1 2
2 2
1
1
2
1
12
1
2
1 2
1
2
TOP OF PARAPET
152' - 0"
TOP OF DRAIN
151' - 1"
TOP OF PARAPET
152' - 0"
TOP OF DRAIN
151' - 1"
TOP OF PARAPET
152' - 0"
TOP OF DRAIN
151' - 1"
TOP OF PARAPET
152' - 0"
TOP OF DRAIN
151' - 1"
TOP OF COLUMN
151' - 1"
TOP OF COLUMN
151' - 1"
TOP OF PARAPET
157' - 0"
TOP OF DRAIN
151' - 1"
TOP OF DRAIN
151' - 1"
TOP OF DRAIN
151' - 1"
TOP OF DRAIN
151' - 1"
TOP OF DRAIN
151' - 1"
TOP OF PARAPET
157' - 0"
TOP OF PARAPET
157' - 0"
A1
A523
A3
A523
A1
A523
A1
A523
A1
A523
A1
A523
A3
A523
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
REMOVE EXISTING ROOFING SYSTEM COMPLETELY
INCLUDING ROOF MEMBRANE, PROTECTION BOARD,
INSULATION, VAPOR BARRIER, ETC.
EXISTING ROOF DRAINS TO BE REUSED.
KEYNOTE LEGEND
1
2
REMOVE TO LINE AND REPLACE PVC. COVER BOARD,
INSULATION AND MOISTURE BARRIER IN THIS AREA AT THIS
LEVEL.
3
EXISTING ROOFING SYSTEM AT THIS LEVEL TO REMAIN
EXCEPT AS NOTED AT PERIMETER.
4
AT THIS LEVEL AROUND TOWER REMOVE EXISTING SEALANT
AT EXISTING TERMINATION ROOF BAR.
5
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
Architectural NEXUS, Inc.
2505 East Parleys Way
Salt Lake City, Utah 84109
T 801.924.5000
http://www.archnexus.com
654321
E
D
C
B
A
PE
R
M
I
T
S
E
T
OW
N
E
R
P
R
O
J
E
C
T
N
U
M
B
E
R
:
5
0
0
0
7
5
1
6
0
2
0
1
0
1
5/
1
8
/
2
0
1
8
8
:
2
1
:
4
4
A
M
DEMOLITION
ROOF PLAN
NLS
7T
H
S
O
U
T
H
2
N
D
E
A
S
T
R
E
X
B
U
R
G
,
I
D
A
H
O
TH
E
C
H
U
R
C
H
O
F
J
E
S
U
S
C
H
R
I
S
T
O
F
L
A
T
T
E
R
D
A
Y
S
A
I
N
T
S
14134.02
05.11.18
Re
x
b
u
r
g
I
d
a
h
o
T
e
m
p
l
e
P
a
r
a
p
e
t
&
R
o
o
f
Construction
Documentation
AD121
BP
1/8" = 1'-0"AD121
A1 MAIN LEVEL ROOF PLAN DEMO
1/8" = 1'-0"AD121
C1 THIRD LEVEL ROOF PLAN DEMO
# Date Revision
1
A. ALL INDICATED ROOF PARAPETS TO BE REMOVED & REPAIRED
PER ARCHITECTURAL ROOF DETAILS.
B. REMOVE, PRESERVE AND REINSTALL ANY ROOF TOP DEVICES
AS NEEDED TO REPAIR ROOF AND PARAPETS.
C. REMOVE & SALVAGE EXISTING ROOF & WALL MOUNTED
EXTERIOR LIGHTING AS REQUIRED FOR NEW WORK. THIS
INCLUDES CONDUITS, J-BOXES, MOUNTING PADS, ETC.
COORDINATE EXTENT WITH OTHER SUB-CONTRACTORS & G.C.
D. SEE REFERENCE DRAWINGS L-9.3& L-9.6 SHOWING
APPROXIMATE LOCATION OF EXISTING LIGHTING FIELD VERIFY
EXTENT OF WORK BEFORE BIDDING.CONTRACTOR WILL BE
RESPONSIBLE FOR REMOVING & REINSTALL ALL EXISTING
LIGHTING, J-BOXES, MOUNTING PADS, CONDUIT, ETC. EVEN IF
NOT IDENTIFIED SPECIFICALLY IN THESE DOCUMENTS.
E. CONTRACTOR TO DOCUMENT LOCATION OF EXISTING LIGHTS
FIXTURES, CONDUITS, AND LIGHT PEDESTALS BEFORE
REMOVAL OF LIGHTS, ETC. CONTRACTOR TO PROVIDE PLAN
WITH LIGHT LOCATIONS WITH DIMENSIONS TO OWNER &
ARCHITECT FOR DOCUMENTATION. LIGHTS, PEDESTAL ETC. TO
BE REINSTALLED IN EXACT LOCATION AFTER INSTALLATION OF
NEW ROOF SYSTEM.
F. THE CONTRACTOR IS RESPONSIBLE FOR ALL MATERIAL BEING
REMOVED & SALVAGED FOR REUSE. ANY NEW MATERIAL
REQUIRED TO REPLACE ANY NON SALVAGEABLE MATERIALS
SHALL BE INCLUDED IN THE CONTRACTOR'S SCOPE OF WORK.
G. ALL ROOFS SHALL HAVE A MINIMUM 1/4" TO 12" SLOPE
H. PROVIDE NEW FLASHING AROUND ALL EXISTING AND NEW
ROOF PENETRATIONS AS APPROVED BY ROOF
MANUFACTURER, i.e.: PIPE VENTS, CONDUIT, LIGHT PEDESTALS,
ETC.
GENERAL NOTE -ROOF PLAN
3
A523
A4
A522
28' - 0" +/-
29
'
-
0
"
+
/
-
2'
-
6
"
2'
-
0
"
20
'
-
0
"
2'
-
0
"
2'
-
6
"
4' - 0"2' - 0"18' - 0"2' - 0"2' - 0"
1 TYPICAL AT TOWER
TOP OF PARAPET
177' - 0"
TOP OF ROOF
183' - 10"
TOP OF ROOF
189' - 0"
TOP OF PARAPET
177' - 0"
TOP OF ROOF
183' - 10"
TOP OF ROOF
189' - 0"
TOP OF PARAPET
177' - 0"
TOP OF DRAIN
175' - 7 - 1/2"
RID
G
E
B1
A522
B1
A522
A1
A522
A1
A522
A1
A522
29' - 9" +/-
119' - 6" +/-
8'
-
3
"
15
'
-
0
"
+
/
-
6'
-
9
"
+
/
-
29' - 9" +/-
8'
-
3
"
21
'
-
8
"
+
/
-
42
'
-
6
"
+
/
-
A1
A522
A1
A522
A1
A522
A1
A522
A1
A522
A1
A522
A1
A522
A1
A522
A1
A522
A1
A522
A1
A522
B1
A522
EXISTING ROOF
HATCH TO REMAIN
(6) EXISTING PIPE VENTS TO REMAIN PROVIDER
AND INSTALL NEW SLEEVES AS NEEDED IF
REMOVAL IS REQUIRED FOR NEW WORK
EXISTING VENT/EXHAUST HOODS TO REMAIN
B1
A522
B1
A522
B1
A522
B1
A522
2
1
112
1
12
1
1 2
1
3
3
3
3
34
4
TOP OF DRAIN
162' -1"
TOP OF PARAPET
164' -0"
TOP OF DRAIN
162' -1"
TOP OF PARAPET
164' -0"TOP OF PARAPET
170' -0"
TOP OF PARAPET
170' -0"
TOP OF DRAIN
162' -1"
TOP OF PARAPET
164' -0"
TOP OF DRAIN
162' -1"
TOP OF PARAPET
164' -0"
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
A1
A523
5A1
A523
REMOVE EXISTING ROOFING SYSTEM COMPLETELY
INCLUDING ROOF MEMBRANE, PROTECTION BOARD,
INSULATION, VAPOR BARRIER, ETC.
EXISTING ROOF DRAINS TO BE REUSED.
KEYNOTE LEGEND
1
2
REMOVE TO LINE AND REPLACE PVC. COVER BOARD,
INSULATION AND MOISTURE BARRIER IN THIS AREA AT THIS
LEVEL.
3
EXISTING ROOFING SYSTEM AT THIS LEVEL TO REMAIN
EXCEPT AS NOTED AT PERIMETER.
4
AT THIS LEVEL AROUND TOWER REMOVE EXISTING SEALANT
AT EXISTING TERMINATION ROOF BAR.
5
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
Architectural NEXUS, Inc.
2505 East Parleys Way
Salt Lake City, Utah 84109
T 801.924.5000
http://www.archnexus.com
654321
E
D
C
B
A
PE
R
M
I
T
S
E
T
OW
N
E
R
P
R
O
J
E
C
T
N
U
M
B
E
R
:
5
0
0
0
7
5
1
6
0
2
0
1
0
1
5/
1
8
/
2
0
1
8
8
:
2
1
:
4
5
A
M
DEMOLITION
MECHANICAL
LEVEL AND
TOWER ROOF
PLANS
NLS
7T
H
S
O
U
T
H
2
N
D
E
A
S
T
R
E
X
B
U
R
G
,
I
D
A
H
O
TH
E
C
H
U
R
C
H
O
F
J
E
S
U
S
C
H
R
I
S
T
O
F
L
A
T
T
E
R
D
A
Y
S
A
I
N
T
S
14134.02
05.11.18
Re
x
b
u
r
g
I
d
a
h
o
T
e
m
p
l
e
P
a
r
a
p
e
t
&
R
o
o
f
Construction
Documentation
AD122
BP
1/8" = 1'-0"AD122
C1 TOWER ROOF PLAN DEMO
1/8" = 1'-0"AD122
A1 MECHANICAL LEVEL ROOF PLAN DEMO
# Date Revision
A. ALL INDICATED ROOF PARAPETS TO BE REMOVED & REPAIRED
PER ARCHITECTURAL ROOF DETAILS.
B. REMOVE, PRESERVE AND REINSTALL ANY ROOF TOP DEVICES
AS NEEDED TO REPAIR ROOF AND PARAPETS.
C. REMOVE & SALVAGE EXISTING ROOF & WALL MOUNTED
EXTERIOR LIGHTING AS REQUIRED FOR NEW WORK. THIS
INCLUDES CONDUITS, J-BOXES, MOUNTING PADS, ETC.
COORDINATE EXTENT WITH OTHER SUB-CONTRACTORS & G.C.
D. SEE REFERENCE DRAWINGS L-9.3& L-9.6 SHOWING
APPROXIMATE LOCATION OF EXISTING LIGHTING FIELD VERIFY
EXTENT OF WORK BEFORE BIDDING.CONTRACTOR WILL BE
RESPONSIBLE FOR REMOVING & REINSTALL ALL EXISTING
LIGHTING, J-BOXES, MOUNTING PADS, CONDUIT, ETC. EVEN IF
NOT IDENTIFIED SPECIFICALLY IN THESE DOCUMENTS.
E. CONTRACTOR TO DOCUMENT LOCATION OF EXISTING LIGHTS
FIXTURES, CONDUITS, AND LIGHT PEDESTALS BEFORE
REMOVAL OF LIGHTS, ETC. CONTRACTOR TO PROVIDE PLAN
WITH LIGHT LOCATIONS WITH DIMENSIONS TO OWNER &
ARCHITECT FOR DOCUMENTATION. LIGHTS, PEDESTAL ETC. TO
BE REINSTALLED IN EXACT LOCATION AFTER INSTALLATION OF
NEW ROOF SYSTEM.
F. THE CONTRACTOR IS RESPONSIBLE FOR ALL MATERIAL BEING
REMOVED & SALVAGED FOR REUSE. ANY NEW MATERIAL
REQUIRED TO REPLACE ANY NON SALVAGEABLE MATERIALS
SHALL BE INCLUDED IN THE CONTRACTOR'S SCOPE OF WORK.
G. ALL ROOFS SHALL HAVE A MINIMUM 1/4" TO 12" SLOPE
H. PROVIDE NEW FLASHING AROUND ALL EXISTING AND NEW
ROOF PENETRATIONS AS APPROVED BY ROOF
MANUFACTURER, i.e.: PIPE VENTS, CONDUIT, LIGHT PEDESTALS,
ETC.
GENERAL NOTE -ROOF PLAN
RID
G
E
RID
G
E
RIDGE
RIDGE
D4
A521
D4
A521
A4
A521
D2
A522
A2
A521
A2
A521
B5
A522
B5
A522
B5
A522
B5
A522
A4
A521
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
B5
A523
B5
A523
B5
A523
A521
A5
A521
A5
B5
A523
D2
A522
D2
A522
37
'
-
3
"
+
/
-
33
'
-
1
1
"
+
/
-
40' - 4" +/-
20' - 6" +/-
21
'
-
4
"
46' - 5" +/-
103' - 9" +/-
2'
-
7
"
2'
-
8
"
21
'
-
6
"
+
/
-
4' - 0"1' - 8"
D2
A522
A4
A521
A4
A521
B5
A522
B5
A522
B5
A522
B5
A522
B5
A523
B5
A523
TYP.
TYP.
TYP.
TYP.
A521
A5
A521
A5
1
1
1
1
1
1
2 2
2 2
2
2
2
2
TOP OF PARAPET
111' - 7"
TOP OF DRAIN
111' - 4 1/2"
TOP OF COLUMN
115' - 10"
TOP OF PARAPET
119' - 2"
TOP OF COLUMN
115' - 10"
TOP OF DRAIN
111' - 4 1/2"
TOP OF PARAPET
111' - 7"
TOP OF DRAIN
111' - 4 1/2"
TOP OF DRAIN
111' - 4 1/2"
TOP OF DRAIN
115' - 7"
TOP OF PARAPET
117' - 0"
TOP OF DRAIN
115' - 7"
TOP OF PARAPET
117' - 0"
TOP OF DRAIN
115' - 7"
TOP OF PARAPET
117' - 0"
TOP OF DRAIN
115' - 1"
TOP OF DRAIN
115' - 1"
TOP OF PARAPET
117' - 0"
TOP OF DRAIN
115' - 1"
TOP OF DRAIN
115' - 1"
TOP OF PARAPET
95' - 7"
TOP OF DRAIN
95' - 4 1/2"
TOP OF PARAPET
94' - 2"
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
6'
-
9
"
+
/
-
3' - 0"1' - 5"
4' - 5" +/-
3'
-
0
"
3'
-
9
"
4'
-
3
"
13
'
-
0
"
4'
-
3
"
5' - 8" +/-
16' - 8"70' - 5"16' - 8"
5'
-
2
"
+
/
-
7"
2' - 6"
9' - 5"30' - 11"
5' - 0"15' - 6"
35
'
-
6
"
1'
-
9
"
7' - 9"4' - 0"34' - 8"
2'
-
6
"
2'
-
6
"
8'
-
0
"
8'
-
0
"
8'
-
0
"
2'
-
6
"
2'
-
6
"
6' - 6" +/-
5' - 0"1' - 6"1'
-
6
"
5'
-
6
"
7'
-
0
"
+
/
-
RID
G
E
RID
G
E
A2
A521
A2
A521
A2
A521
A2
A521
A2
A521
4
A523
A2
A521
A2
A521
A5
A523A5
A523
A5
A523
A5
A523
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
105' - 5" +/-
24
'
-
1
1
"
+
/
-
7' - 7" +/-
7'
-
4
"
+
/
-
4
A523 A521
A5
A2
A521
A2
A521
A2
A521
A5
A523
A2
A521
A2
A521
A2
A521
A2
A521
A2
A521
A2
A521
A2
A521
2 2
2 2
2
2
2
2
2
1
1 1
1
1
1
1
1
1
1
1
TOP OF PARAPET
152' - 0"
TOP OF DRAIN
151' - 1"
TOP OF PARAPET
152' - 0"
TOP OF DRAIN
151' - 1"
TOP OF PARAPET
152' - 0"
TOP OF DRAIN
151' - 1"
TOP OF PARAPET
152' - 0"
TOP OF DRAIN
151' - 1"
TOP OF COLUMN
151' - 1"
TOP OF COLUMN
151' - 1"
TOP OF PARAPET
157' - 0"
TOP OF DRAIN
151' - 1"
TOP OF DRAIN
151' - 1"
TOP OF DRAIN
151' - 1"
TOP OF DRAIN
151' - 1"
TOP OF DRAIN
151' - 1"
TOP OF PARAPET
157' - 0"
TOP OF PARAPET
157' - 0"
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
25' - 6" +/-
17' - 6"6' - 8"1' - 4"
2'
-
7
"
5'
-
1
0
"
3'
-
3
"
11
'
-
8
"
+
/
-
25' - 6" +/-
11
'
-
8
"
+
/
-
1' - 4"6' - 8"17' - 6"
2'
-
7
"
5'
-
1
0
"
3'
-
3
"
12' - 4"80' - 10"12' - 3"
9'
-
1
"
8'
-
3
"
17
'
-
4
"
+
/
-
5'
-
0
"
15
'
-
0
"
5'
-
0
"
6' - 9"10' - 4"
17' - 1" +/-
10"6' - 9"
4'
-
3
"
3'
-
0
"
NEW PVC ROOFING SYSTEM TO MATCH EXISTING.
INCLUDING ROOF MEMBRANE, PROTECTION BOARD,
INSULATION, ETC. MATCH EXISTING INSULATION "R" VALUE
AND ROOF SLOPES.
EXISTING ROOF DRAINS TO BE REUSED.
KEYNOTE LEGEND
1
2
PROVIDE AND INSTALL NEW SEALANT AT EXISTING
TERMINATION ROOF BAR. ALSO PROVIDE AND INSTALL NEW
COUNTER FLASHING OVER EXISTING ROOF TERMINATION
BAR WITH SEALANT. MATCH NEW COUNTER FLASHING. SEE
TYPICAL TERMINATION BAR DETAIL.
3
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
Architectural NEXUS, Inc.
2505 East Parleys Way
Salt Lake City, Utah 84109
T 801.924.5000
http://www.archnexus.com
654321
E
D
C
B
A
PE
R
M
I
T
S
E
T
OW
N
E
R
P
R
O
J
E
C
T
N
U
M
B
E
R
:
5
0
0
0
7
5
1
6
0
2
0
1
0
1
5/
1
8
/
2
0
1
8
8
:
2
1
:
2
8
A
M
ROOF PLAN
NLS
7T
H
S
O
U
T
H
2
N
D
E
A
S
T
R
E
X
B
U
R
G
,
I
D
A
H
O
TH
E
C
H
U
R
C
H
O
F
J
E
S
U
S
C
H
R
I
S
T
O
F
L
A
T
T
E
R
D
A
Y
S
A
I
N
T
S
14134.02
05.11.18
Re
x
b
u
r
g
I
d
a
h
o
T
e
m
p
l
e
P
a
r
a
p
e
t
&
R
o
o
f
Construction
Documentation
A121
BP
1/8" = 1'-0"A121
A1 MAIN LEVEL ROOF PLAN
1/8" = 1'-0"A121
C1 THIRD LEVEL ROOF PLAN
# Date Revision
RID
G
E
B2
A522
B2
A522
A2
A522
A2
A522
A2
A522
29' - 9" +/-
119' - 6" +/-
15
'
-
0
"
+
/
-
29' - 9" +/-
22
'
-
0
"
+
/
-
42
'
-
6
"
+
/
-
A2
A522
A2
A522
A2
A522
A2
A522
A2
A522
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A521
A5
A2
A522
A2
A522
A2
A522
A2
A522
A2
A522
A2
A522
B2
A522
EXISTING ROOF
HATCH TO REMAIN
(6) EXISTING PIPE VENTS TO REMAIN REPLACE
W/ NEW SLEEVES AS NEEDED IF REMOVAL IS
REQUIRED FOR NEW WORK
EXISTING VENT/EXHAUST HOODS TO REMAIN
1
11
1
1
1
1
1
22
2
2
A3
A523
A3
A523
TOP OF DRAIN
162' -1"
TOP OF PARAPET
164' -0"
TOP OF DRAIN
162' -1"
TOP OF PARAPET
164' -0"TOP OF PARAPET
170' -0"
TOP OF PARAPET
170' -0"
TOP OF DRAIN
162' -1"
TOP OF PARAPET
164' -0"
TOP OF DRAIN
162' -1"
TOP OF PARAPET
164' -0"
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
A3
A523
10' - 4"19' - 4"
113' - 8"5' - 11"
19' - 4"10' - 4"
8'
-
3
"
13
'
-
9
"
8'
-
3
"
6'
-
9
"
6'
-
9
"
29
'
-
0
"
6'
-
9
"
A3
A523
3
4
A523
A5
A522
A521
A5
A521
A5
A521
A5
A521
A5
28' - 0" +/-
29
'
-
0
"
+
/
-
2'
-
6
"
2'
-
0
"
2'
-
6
"
15
'
-
0
"
2'
-
6
"
2'
-
0
"
2'
-
6
"
4' - 0"2' - 0"2' - 6"15' - 6"2' - 0"2' - 0"
1 TYPICAL AT TOWER
TOP OF PARAPET
177' - 0"
TOP OF ROOF
183' - 10"
TOP OF ROOF
189' - 0"
TOP OF PARAPET
177' - 0"
TOP OF ROOF
183' - 10"
TOP OF ROOF
189' - 0"
TOP OF PARAPET
177' - 0"
TOP OF DRAIN
175' - 7 - 1/2"
A. ALL INDICATED ROOF PARAPETS TO BE REMOVED & REPAIRED
PER ARCHITECTURAL ROOF DETAILS.
B. REMOVE, PRESERVE AND REINSTALL ANY ROOF TOP DEVICES
AS NEEDED TO REPAIR ROOF AND PARAPETS.
C. REMOVE & SALVAGE EXISTING ROOF & WALL MOUNTED
EXTERIOR LIGHTING AS REQUIRED FOR NEW WORK. THIS
INCLUDES CONDUITS, J-BOXES, MOUNTING PADS, ETC.
COORDINATE EXTENT WITH OTHER SUB-CONTRACTORS & G.C.
D. SEE REFERENCE DRAWINGS L-9.3& L-9.6 SHOWING
APPROXIMATE LOCATION OF EXISTING LIGHTING FIELD VERIFY
EXTENT OF WORK BEFORE BIDDING.CONTRACTOR WILL BE
RESPONSIBLE FOR REMOVING & REINSTALL ALL EXISTING
LIGHTING, J-BOXES, MOUNTING PADS, CONDUIT, ETC. EVEN IF
NOT IDENTIFIED SPECIFICALLY IN THESE DOCUMENTS.
E. CONTRACTOR TO DOCUMENT LOCATION OF EXISTING LIGHTS
FIXTURES, CONDUITS, AND LIGHT PEDESTALS BEFORE
REMOVAL OF LIGHTS, ETC. CONTRACTOR TO PROVIDE PLAN
WITH LIGHT LOCATIONS WITH DIMENSIONS TO OWNER &
ARCHITECT FOR DOCUMENTATION. LIGHTS, PEDESTAL ETC. TO
BE REINSTALLED IN EXACT LOCATION AFTER INSTALLATION OF
NEW ROOF SYSTEM.
F. THE CONTRACTOR IS RESPONSIBLE FOR ALL MATERIAL BEING
REMOVED & SALVAGED FOR REUSE. ANY NEW MATERIAL
REQUIRED TO REPLACE ANY NON SALVAGEABLE MATERIALS
SHALL BE INCLUDED IN THE CONTRACTOR'S SCOPE OF WORK.
G. ALL ROOFS SHALL HAVE A MINIMUM 1/4" TO 12" SLOPE
H. PROVIDE NEW FLASHING AROUND ALL EXISTING AND NEW
ROOF PENETRATIONS AS APPROVED BY ROOF
MANUFACTURER, i.e.: PIPE VENTS, CONDUIT, LIGHT PEDESTALS,
ETC.
GENERAL NOTE -ROOF PLAN
NEW PVC ROOFING SYSTEM TO MATCH EXISTING.
INCLUDING ROOF MEMBRANE, PROTECTION BOARD,
INSULATION, ETC. MATCH EXISTING INSULATION "R" VALUE
AND ROOF SLOPES.
EXISTING ROOF DRAINS TO BE REUSED.
KEYNOTE LEGEND
1
2
PROVIDE AND INSTALL NEW SEALANT AT EXISTING
TERMINATION ROOF BAR. ALSO PROVIDE AND INSTALL NEW
COUNTER FLASHING OVER EXISTING ROOF TERMINATION
BAR WITH SEALANT. MATCH NEW COUNTER FLASHING. SEE
TYPICAL TERMINATION BAR DETAIL.
3
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
Architectural NEXUS, Inc.
2505 East Parleys Way
Salt Lake City, Utah 84109
T 801.924.5000
http://www.archnexus.com
654321
E
D
C
B
A
PE
R
M
I
T
S
E
T
OW
N
E
R
P
R
O
J
E
C
T
N
U
M
B
E
R
:
5
0
0
0
7
5
1
6
0
2
0
1
0
1
5/
1
8
/
2
0
1
8
8
:
2
1
:
2
9
A
M
MECHANICAL
LEVEL AND
TOWER ROOF
PLANS
NLS
7T
H
S
O
U
T
H
2
N
D
E
A
S
T
R
E
X
B
U
R
G
,
I
D
A
H
O
TH
E
C
H
U
R
C
H
O
F
J
E
S
U
S
C
H
R
I
S
T
O
F
L
A
T
T
E
R
D
A
Y
S
A
I
N
T
S
14134.02
05.11.18
Re
x
b
u
r
g
I
d
a
h
o
T
e
m
p
l
e
P
a
r
a
p
e
t
&
R
o
o
f
Construction
Documentation
A122
BP
1/8" = 1'-0"A122
A1 MECHANICAL LEVEL ROOF PLAN
1/8" = 1'-0"A122
C1 TOWER ROOF PLAN
# Date Revision
EXISTING PRE-CAST
CONCRETE PANEL
EXISTING 5/8" EXTERIOR
GYPSUM SHEATHING
EXISTING METAL STUD
REMOVE VERTICAL PORTION
OF EXISTING ROOF
MEMBRANE
A522
D4
REMOVE EXISTING ROOFING
SYSTEM.
REMOVE EXISTING
BATT INSULATION
SCALE: 1 1/2" = 1'-0"
REMOVE EXISTING
INSULATION.
REMOVE EXISTING 5/8"
EXTERIOR GYPSUM
SHEATHING.
REMOVE PORTION OF
EXISTING ROOF PROTECTION
BOARD TO ACCESS
INSULATION
EXISTING PRE-CAST
CONCRETE PANEL
NEW 5/8"
EXTERIOR
GYPSUM
SHEATHING
EXISTING METAL STUD
NEW ROOFING SYSTEM
A522
D5
NEW 24 GA. ALUMINUM L3"X3"
ANGLE SET IN A BED OF
CONTINUOUS MASTIC.
MECHANICALLY ATTACH TO
VERTICAL & HORIZONTAL
SURFACES MIN. 12" O.C. IN
CONTINUOUS MASTIC.
SCALE: 1 1/2" = 1'-0"
FIELD VERIFY
2" + OR -
NEW 5/8" EXTERIOR GYPSUM
BOARD.
NEW ROOFING SYSTEM.
NEW CLOSED CELL SPRAY
FOAM INSULATION -FILL
SOLID
NEW LARGE CLOSED CELL
BACKER ROD
EXISTING PRECAST PANEL
PVC
ROOFING
STEP 1: SEAL JOINT BETWEEN PRECAST
WALL AND PARAPET WALL
STEP 1B: FILL SOLID ANY REVEAL WHERE
IT INTERSECTS THE PARAPET EXISTING PVC OVER TOP OF
PARAPET ADD NEW PVC ROOF
MEMBRANE OVER TOP OF PARAPET
SO IT LAPS THE VERTICAL FACE. SEE
DETAIL D5/A522
STEP 3:INSTALL FLEXIBLE SELF-
ADHERED MEMBRANE IN FULLY FORMED
SADDLE
STEP 2: APPLY BUTYL BASED SELF
ADHESIVE MEMBRANE (2' MIN. LAP EACH
SIDE) ALONG THE JOINT WHERE PARAPET
BUTTS ONTO PRECAST
STEP 4:SEAL ALL EDGES WITH
SILICONE SEALANT
STEP 1
4
"
.
NEW PREFINISHED
PARAPET COPING SEE
DETAIL D5/A522
NEW 20
GAGE
METAL
SADDLE
SEALANT ALONG GUM
LIP TERMINATION
GUM LIP TERMINATION TO
RECEIVE SEALANT
FULLY SOLDERED
METAL SADDLE
GASKETED FASTENER, FINISH TO
MATCH EXISTING COPING
STEP 2
4
"
.
FINISH TO MATCH
EXISTING METAL
COPING
VE
R
I
F
Y
4"
+
O
R
-
4".
4".
GRID
GRID
GRID
SCALE: 1" = 1'-0"
EXISTING PRE-CAST PANEL
EXISTING PRE-CAST PANEL
EXISTING CONCRETE
& METAL DECK
REMOVE EXISTING ROOFING SYSTEM
REMOVE EXISTING TERMINATION BAR
REMOVE SEALANT
EXISTING CONCRETE CURB
EXTERIOR
BUILDING LIGHTING,
REMOVE, SALVAGE TO DO
NEW WIC, AS REQUIRED
EXISTING
ELECTRICAL
CONDUIT THRU
ROOF
REMOVE EXISTING
BATT INSULATION
7
1
/
2
"
.
A522
D4
REMOVE EXISTING ROOF
PROTECTION BOARD &
INSULATION AS REQUIRED
FOR ACCESS TO REMOVE
EXISTING BATT INSULATION.
SALVAGE FOR REUSE.
REMOVE EXISTING ROOFING
SYSTEM
REMOVE EXISTING ROOF
INSULATION.
REMOVE
A523
A1
SIM.
GRID
GRID
GRID
SCALE: 1" = 1'-0"
EXISTING PRE-CAST PANEL
EXISTING PRE-CAST PANEL
EXISTING CONCRETE
& METAL DECK
EXISTING ROOFING SYSTEM
EXISTING TERMINATION STRIP
NEW SEALANT (CONT.)
EXISTING CONCRETE CURB
REINSTALL EXISTING BUILDING LIGHTING, IN ORIGINAL
LOCATION. AIM LIGHTS IN DIRECTION & LOCATION AS
BEFORE. WILL REQUIRE A NIGHT TIME SESSION WITH THE
OWNER AND THE ARCHITECT TO VERIFY LIGHTING AIM.
PROVIDE NEW FLASHING AROUND ROOF PENETRATION AS
APPROVED BY ROOFING MANUFACTURER
EXISTING
ELECTRICAL
CONDUIT THRU
ROOF
7
1
/
2
"
.
A522
D5
REINSTALL NEW INSULATION
MATCH EXISTING QUALITY &
THICKNESS.
NEW ROOFING SYSTEM &
NEW PROTECTION BOARD AS
REQUIRED.
NEW CLOSED CELL SPRAY
FOAM INSULATION -FILL
SOLID
NEW LARGE CLOSED CELL
BACKER ROD
FIELD VERIFY
2" + OR -
NEW 24 GA. ALUMINUM L3"X3"
ANGLE SET IN A BED OF
CONTINUOUS MASTIC.
MECHANICALLY ATTACH TO
VERTICAL SURFACES MIN. 12"
O.C. IN CONTINUOUS MASTIC.
A523
A3
SIM.
SCALE: 1 1/2" = 1'-0"
EXISTING METAL ROOF
DECK
EXISTING CONCRETE DECK
EXISTING ROOFING SYSTEM
TO BE REMOVED
EXISTING PRE-CAST
CONCRETE PANEL
A522
D4
REMOVE PORTION OF
EXISTING 5/8" EXTERIOR
GYPSUM SHEATHING AS
REQUIRED TO GAIN ACCESS
TO JOINT BETWEEN
CONCRETE. SLAB AND
EXTERIOR PRECAST.
REMOVE EXISTING ROOF
SYSTEM COMPLETELY TO
METAL DECK
REMOVE EXISTING BATT
INSULATION
SCALE: 1 1/2" = 1'-0"
EXISTING ROOF DECK
EXISTING CONCRETE DECK
NEW ROOFING SYSTEM TO
EXTEND UP WALL AND
UNDER PARAPET CAP.
EXISTING PRE-CAST
CONCRETE PANEL
A522
D5
NEW ROOFING SYSTEM,
PROTECTION BOARD,
INSULATION,ETC.
CLOSED CELL SPRAY FOAM
INSULATION -FILL SOLID
LARGE CLOSED CELL
BACKER ROD
NEW 24 GA. ALUMINUM L3"X3"
ANGLE SET IN A BED OF
CONTINUOUS MASTIC.
MECHANICALLY ATTACH TO
VERTICAL SURFACES MIN. 12"
O.C. IN CONTINUOUS MASTIC.
A. SLOPE ALL ROOF SYSTEMS TO DRAIN. VERIFY ALL
CONDITIONS WITH ROOF SYSTEM
MANUFACTURER FOR WARRANTY.
B. MAKE SURE THAT WATER/WATER VAPOR CAN
ESCAPE AND DRY AT BACK OF ALL PRECAST
PANELS.
GENERAL NOTE -
ARCHITECTURAL ROOF DETAILS
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
Architectural NEXUS, Inc.
2505 East Parleys Way
Salt Lake City, Utah 84109
T 801.924.5000
http://www.archnexus.com
654321
E
D
C
B
A
PE
R
M
I
T
S
E
T
OW
N
E
R
P
R
O
J
E
C
T
N
U
M
B
E
R
:
5
0
0
0
7
5
1
6
0
2
0
1
0
1
5/
1
8
/
2
0
1
8
8
:
2
1
:
3
4
A
M
ARCHITECTURAL
ROOF DETAILS
NLS
7T
H
S
O
U
T
H
2
N
D
E
A
S
T
R
E
X
B
U
R
G
,
I
D
A
H
O
TH
E
C
H
U
R
C
H
O
F
J
E
S
U
S
C
H
R
I
S
T
O
F
L
A
T
T
E
R
D
A
Y
S
A
I
N
T
S
14134.02
05.11.18
Re
x
b
u
r
g
I
d
a
h
o
T
e
m
p
l
e
P
a
r
a
p
e
t
&
R
o
o
f
Construction
Documentation
A521
BP
A521
A1 PARAPET WALL DETAIL EXISTING
A521
A2 PARAPET WALL DETAIL NEW
NTSA521
A5 PARAPET TO PRECAST INTERFACE SADDLE
A521
D1 ROOF DETAIL EXISTING
A521
D4 ROOF DETAIL NEW
A521
A3 PARAPET DETAIL EXISTING
A521
A4 PARAPET DETAIL NEW
# Date Revision
GRID
SCALE: 1" = 1'-0"
EXISTING CONCRETE &
METAL DECK
REMOVE EXISTING ROOFING
SYSTEM
EXISTING PRE-CAST PANEL
REMOVE EXISTING
BATT INSULATION
A522
D4
REMOVE EXISTING ROOFING
REMOVE EXISTING
INSULATION.
REMOVE EXISTING 5/8"
EXTERIOR GYPSUM
SHEATHING.
REMOVE EXISTING ROOF
PROTECTION BOARD.
GRID
SCALE: 1" = 1'-0"
NEW ROOFING SYSTEM
EXISTING PRE-CAST PANEL
EXISTING CONCRETE
& METAL DECK
A522
D5
NEW PVC ROOFING SYSTEM
W/ NEW PROTECTION BOARD
AND INSULATION.
NEW INSULATION TO MATCH
EXISTING QUALITY &
THICKNESS.
CLOSED CELL SPRAY FOAM
INSULATION -FILL SOLID
LARGE CLOSED CELL BACKER ROD
NEW 24 GA. ALUMINUM L3"X3" ANGLE
SET IN A BED OF CONTINUOUS
MASTIC. MECHANICALLY ATTACH TO
VERTICAL SURFACES MIN. 12" O.C. IN
CONTINUOUS MASTIC.
GRID GRID
SCALE: 1" = 1'-0"
EXISTING METAL DECK
EXISTING PRE-CAST PANEL
REMOVE EXISTING
BATT INSULATION
A522
D4
EXISTING ROOFING SYSTEM
PEAL BACK AND SALVAGE
EXISTING ROOFING SYSTEM
FOR REUSE.
EXISTING ROOFING SYSTEM
REMOVE EXISTING
INSULATION AS
REQUIRED TO
ACCESS AND
REMOVE EXISTING
BATT INSULATION
REMOVE PORTION OF
EXISTING 5/8" EXTERIOR
GYPSUM SHEATHING AS
REQUIRED TO GAIN ACCESS
TO JOINT BETWEEN
CONCRETE. SLAB AND
EXTERIOR PRECAST.
REMOVE PORTION OF
EXISTING ROOF PROTECTION
BOARD TO ACCESS
INSULATION
TO ACCESS AREA FOR NEW WORK
REMOVE PORTION OF EXISTING ROOF
REMOVE ONLY THE UPPER LAYER
OF INSULATION IN THIS AREA.
3' - 0".
1' - 0".
GRID GRID
SCALE: 1" = 1'-0"
EXISTING METAL DECK
EXISTING PRE-CAST PANEL
EXISTING ROOFING SYSTEM
A522
D5
REPLACE INSULATION
NEW ROOFING SYSTEM &
INSTALL NEW PROTECTION
BOARD AS REQUIRED.
REINSTALL SALVAGED
EXISTING INSULATION OR
PROVIDE NEW TO MATCH
EXISTING QUALITY &
THICKNESS. SEAL JOINTS
WITH COMPATIBLE FOAM
INSULATION.
CLOSED CELL SPRAY FOAM
INSULATION -FILL SOLID
LARGE CLOSED CELL BACKER ROD
NEW 24 GA. ALUMINUM L3"X3"
ANGLE SET IN A BED OF
CONTINUOUS MASTIC.
MECHANICALLY ATTACH TO
VERTICAL SURFACES MIN. 12"
O.C. IN CONTINUOUS MASTIC.
3' - 0".
1' - 0".
STAGGER INSULATION LAYERS
SEAL NEW MEMBRANE TO
EXISTING AND EXTEND UP
PARAPET WALL AND OVER
TOP OF PARAPET.
GRID GRID
SCALE: 1" = 1'-0"
EXISTING PRE-CAST CONCRETE PANEL
EXISTING CONCRETE & METAL DECK
REMOVE EXISTING ROOFING SYSTEM.
REMOVE EXISTING TERMINATION BAR
REMOVE SEALANT
REMOVE EXISTING EXT. LIGHT SALVAGE FOR REUSE
EXISTING ELECTRICAL CONDUIT THROUGH
ROOF TO REMAIN.
A522
D4
REMOVE EXISTING ROOFING SYSTEM.
REMOVE EXISTING BATT INSULATION
REMOVE EXISTING INSULATION.
REMOVE EXISTING 5/8" EXTERIOR GYPSUM SHEATHING.
REMOVE EXISTING ROOF PROTECTION BOARD.
A523
A1 GRID GRID
SCALE: 1" = 1'-0"
EXISTING PRE-CAST CONCRETE PANEL
EXISTING CONCRETE & METAL DECK
NEW TERMINATION BAR
NEW SEALANT (CONT.)
REINSTALL EXISTING BUILDING
LIGHTING, IN ORIGINAL LOCATION. AIM
LIGHTS IN DIRECTION & LOCATION AS
BEFORE. WILL REQUIRE A NIGHT TIME
SESSION WITH THE OWNER AND THE
ARCHITECT TO VERIFY LIGHTING AIM.
EXISTING ELECTRICAL
CONDUIT THRU ROOF.
A522
D5
NEW INSULATION TO MATCH EXISTING
QUALITY & THICKNESS.
NEW ROOFING SYSTEM WITH
PROTECTION BOARD
CLOSED CELL SPRAY FOAM
INSULATION -FILL SOLID
LARGE CLOSED CELL BACKER ROD
A523
A3
NEW 24 GA. ALUMINUM L3"X3" ANGLE
SET IN A BED OF CONTINUOUS
MASTIC. MECHANICALLY ATTACH TO
VERTICAL SURFACES MIN. 12" O.C. IN
CONTINUOUS MASTIC.
8"
M
I
N
.
T
Y
P
.
GRID
SCALE: 1" = 1'-0"
REMOVE EXISTING
TERMINATION BAR
REMOVE SEALANT
REMOVE ROOFING SYSTEM
EXISTING CONCRETE CURB
EXISTING PRE-CAST PANEL
EXISTING CONCRETE
TOPPING & METAL DECK
EXISTING EXT. LIGHT.
REMOVE, TO COMPLETE
NEW WORK IN CONTRACT,
SALVAGE FOR REINSTALL
REMOVE EXISTING BATT
INSULATION
A522
D4
REMOVE EXISTING ROOFING SYSTEM.
REMOVE EXISTING
INSULATION.
REMOVE PORTION OF EXISTING
5/8" EXTERIOR GYPSUM
SHEATHING AS REQUIRED TO
GAIN ACCESS TO JOINT
BETWEEN CONCRETE. SLAB
AND EXTERIOR PRECAST.
REMOVE EXISTING ROOF
PROTECTION BOARD TO
ACCESS INSULATION
INSULATION TO DECK
REMOVE
A523
A1
GRID
SCALE: 1" = 1'-0"
EXISTING TERMINATION BAR
NEW SEALANT (CONT.)
NEW ROOFING SYSTEM
EXISTING CONCRETE CURB
EXISTING PRE-CAST PANEL
EXISTING CONCRETE
TOPPING & METAL DECK
A522
D5
REINSTALL NEW INSULATION
MATCH EXISTING QUALITY &
THICKNESS.
REINSTALL EXISTING BUILDING
LIGHTING, IN ORIGINAL
LOCATION. AIM LIGHTS IN
DIRECTION & LOCATION AS
BEFORE. WILL REQUIRE A NIGHT
TIME SESSION WITH THE
OWNER AND THE ARCHITECT TO
VERIFY LIGHTING AIM.
CLOSED CELL SPRAY FOAM
INSULATION -FILL SOLID
LARGE CLOSED CELL
BACKER ROD
A523
A3
NEW 24 GA. ALUMINUM L3"X3" ANGLE
SET IN A BED OF CONTINUOUS
MASTIC. MECHANICALLY ATTACH TO
VERTICAL SURFACES MIN. 12" O.C. IN
CONTINUOUS MASTIC.
SCALE: 6" = 1'-0"
EXISTING PRE-CAST
CONCRETE PANEL
NEW PREFINISHED
METAL COPING W/ STANDING
SEAM JOINTS MATCH
EXISTING FINISH.
NEW ROOF MEMBRANE UP
UNDER PARAPET CAP AND
DOWN VERTICAL FACE AS
SHOWN
FIELD VERIFY
4"
VA
R
I
E
S
5
"
-
8
"
2"
CONT. SEALANT -COORDINATE
TYPE OF SEALANT WITH
ROOFING MANUFACTURE.
EXTEND ROOFING MEMBRANE
TO BOTTOM OF FLASHING
NEW ROOF MEMBRANE.
EXPOSED SIDE ROOF SIDE
SCALE: 6" = 1'-0"
PRE-CAST
CONCRETE PANEL
REMOVE AND DISCARD
PREFINISHED METAL COPING
REMOVE EXISTING
ROOFING
MEMBRANE
FIELD VERIFY
A. SLOPE ALL ROOF SYSTEMS TO DRAIN. VERIFY ALL
CONDITIONS WITH ROOF SYSTEM
MANUFACTURER FOR WARRANTY.
B. MAKE SURE THAT WATER/WATER VAPOR CAN
ESCAPE AND DRY AT BACK OF ALL PRECAST
PANELS.
GENERAL NOTE -
ARCHITECTURAL ROOF DETAILS
GRID GRID
SCALE: 1" = 1'-0"
EXISTING METAL DECK
A522
D4
REMOVE EXISTING ROOFING
SYSTEM
EXISTING PRE-CAST PANEL
REMOVE EXISTING
BATT INSULATION
REMOVE EXISTING ROOFING
REMOVE EXISTING
INSULATION.
REMOVE EXISTING 5/8"
EXTERIOR GYPSUM
SHEATHING.
REMOVE EXISTING ROOF
PROTECTION BOARD.
GRID GRID
SCALE: 1" = 1'-0"
EXISTING METAL DECK
A522
D5
NEW 24 GA. ALUMINUM L3"X3"
ANGLE SET IN A BED OF
CONTINUOUS MASTIC.
MECHANICALLY ATTACH TO
VERTICAL SURFACES MIN. 12"
O.C. IN CONTINUOUS MASTIC.
NEW ROOFING SYSTEM
EXISTING PRE-CAST PANEL
NEW PVC ROOFING SYSTEM
W/ NEW PROTECTION BOARD
AND INSULATION.
NEW INSULATION TO MATCH
EXISTING QUALITY &
THICKNESS.
CLOSED CELL SPRAY FOAM
INSULATION -FILL SOLID
LARGE CLOSED CELL BACKER ROD
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
Architectural NEXUS, Inc.
2505 East Parleys Way
Salt Lake City, Utah 84109
T 801.924.5000
http://www.archnexus.com
654321
E
D
C
B
A
PE
R
M
I
T
S
E
T
OW
N
E
R
P
R
O
J
E
C
T
N
U
M
B
E
R
:
5
0
0
0
7
5
1
6
0
2
0
1
0
1
5/
1
8
/
2
0
1
8
8
:
2
1
:
3
9
A
M
ARCHITECTURAL
ROOF DETAILS
NLS
7T
H
S
O
U
T
H
2
N
D
E
A
S
T
R
E
X
B
U
R
G
,
I
D
A
H
O
TH
E
C
H
U
R
C
H
O
F
J
E
S
U
S
C
H
R
I
S
T
O
F
L
A
T
T
E
R
D
A
Y
S
A
I
N
T
S
14134.02
05.11.18
Re
x
b
u
r
g
I
d
a
h
o
T
e
m
p
l
e
P
a
r
a
p
e
t
&
R
o
o
f
Construction
Documentation
A522
BP
A522
A1 TYP. PARAPET CAP DETAIL EXISTING
A522
A2 TYP. PARAPET CAP DETAIL NEW
A522
B1 TYP. PARAPET CAP DETAIL EXISTING
A522
B2 TYP. PARAPET CAP DETAIL NEW
A522
A4 PARAPET CAP DETAIL EXISTING
A522
A5 PARAPET CAP DETAIL NEW
A522
B4 PARAPET CAP DETAIL EXISTING
A522
B5 PARAPET CAP DETAIL NEW
A522
D5 PARAPET CAP DETAIL NEW
A522
D4 PARAPET CAP DETAIL EXISTING
# Date Revision
A522
D1 TYP. PARAPET CAP DETAIL EXISTING
A522
D2 TYP. PARAPET CAP DETAIL NEW
GRID
SCALE: 1" = 1'-0"
EXISTING CONCRETE
& METAL DECK
EXISTING CONCRETE CURB
REMOVE
EXISTING
ROOFING SYSTEM
REMOVE TERMINATION BAR
REMOVE EXISTING SEALANT
EXISTING PRE-CAST PANEL
REMOVE EXISTING BATT INSULATION
A522
D4
REMOVE ROOFING SYSTEM.
8"
.
REMOVE EXISTING INSULATION
REMOVE EXISTING 5/8" EXTERIOR
GYPSUM SHEATHING.
REMOVE OF EXISTING ROOF
PROTECTION BOARD.
A523
A1 GRID
SCALE: 1" = 1'-0"
EXISTING CONCRETE
& METAL DECK
EXISTING CONCRETE CURB
NEW ROOFING
SYSTEM
NEW TERMINATION BAR
NEW COUNTER
FLASHING & SEALANT
EXISTING PRE-CAST PANEL
A522
D5 3
3
/
8
"
.
SIM.
NEW ROOFING SYSTEM &
NEW PROTECTION BOARD
NEW INSULATION TO MATCH
EXISTING QUALITY &
THICKNESS.
CLOSED CELL SPRAY FOAM
INSULATION -FILL SOLID
LARGE CLOSED CELL
BACKER ROD
A523
A3
GRID
EXISTING
STRUCTURAL BEAM
EXISTING PRE-CAST
STRUCTURAL
COLUMN.
EXISTING
METAL DECK
EXISTING PRE-CAST
CONCRETE PANEL
REMOVE EXISTING
ROOFING SYSTEM
REMOVE EXISTING
ROOFING SYSTEM
A522
D4
SIM.
GRID
EXISTING
STRUCTURAL BEAM
EXISTING PRE-CAST
STRUCTURAL
COLUMN.
EXISTING
METAL DECK
EXISTING PRE-CAST
CONCRETE PANEL
NEW ROOFING
SYSTEM
SIM.A522
D5
A. SLOPE ALL ROOF SYSTEMS TO DRAIN. VERIFY ALL
CONDITIONS WITH ROOF SYSTEM
MANUFACTURER FOR WARRANTY.
B. MAKE SURE THAT WATER/WATER VAPOR CAN
ESCAPE AND DRY AT BACK OF ALL PRECAST
PANELS.
GENERAL NOTE -
ARCHITECTURAL ROOF DETAILS
SCALE: 3" = 1'-0"
NEW TERMINATION BAR
NEW SEALANT (CONT.)
NEW ROOFING
SYSTEM
NEW SEALANT (CONT.)
NEW COUNTER FLASHING
8"
M
I
N
.
SCALE: 3" = 1'-0"
MOVE EXISTING
TERMINATION BAR
REMOVE EXISTING SEALANT
REMOVE EXISTING
ROOFING SYSTEM
GRIDGRID
SCALE: 1 1/2" = 1'-0"
EXISTING PRE-CAST
CONCRETE PANEL
EXISTING PRE-CAST
CONCRETE PANEL
REMOVE EXISTING TERMINATION BAR
REMOVE SEALANT
REMOVE PREFINISHED METAL
COPING WITH
PROTECTION BOARD AND
ROOFING MEMBRANE
UNDERNEATH AGAINST
STRUCTURE.
EXISTING CONCRETE
& METAL DECK
EXISTING EXT. LIGHT
REMOVE, & SALVAGE FOR
REINSTALL AS REQUIRED
EXISTING ELECTRICAL
CONDUIT. TO REMAIN
REMOVE EXISTING
FLASHING AND
COUNTERFLASHING
REMOVE EXISTING
BATT INSULATION
4
5
/
8
"
+
/
-
A523
A1
SIM.
GRIDGRID
SCALE: 1 1/2" = 1'-0"
EXISTING PRE-CAST
CONCRETE PANEL
EXISTING PRE-CAST
CONCRETE PANEL
NEW TERMINATION BAR
NEW SEALANT CONTINUOUS
NEW PREFINISHED METAL COPING WITH
PROTECTION BOARD AND ROOFING
MEMBRANE UNDERNEATH AGAINST
STRUCTURE. SLOPE 1/4" PER 1'-0" MIN.
EXISTING CONCRETE
& METAL DECK
EXISTING ELECTRICAL
CONDUIT.
NEW FLASHING AND COUNTERFLASHING
8"
+
/
-
4"
REINSTALL EXISTING BUILDING LIGHTING,
( IF REMOVED) IN ORIGINAL LOCATION. AIM
LIGHTS IN DIRECTION & LOCATION AS
BEFORE. WILL REQUIRE A NIGHT TIME
SESSION WITH THE OWNER AND THE
ARCHITECT TO VERIFY LIGHTING AIM.
NEW CLOSED CELL SPRAY
FOAM INSULATION -FILL
SOLID
NEW LARGE CLOSED CELL BACKER ROD
A523
A3
SIM.
EXTEND ROOF MEMBRANE UNDER METAL
FLASHING AND THEN ADDITIONAL LAYER
ON TOP OF FLASHING ON HORIZONTAL
SLOPE SURFACE. SEAL AS PER ROOFING
MANUFACTURE.
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
Architectural NEXUS, Inc.
2505 East Parleys Way
Salt Lake City, Utah 84109
T 801.924.5000
http://www.archnexus.com
654321
E
D
C
B
A
PE
R
M
I
T
S
E
T
OW
N
E
R
P
R
O
J
E
C
T
N
U
M
B
E
R
:
5
0
0
0
7
5
1
6
0
2
0
1
0
1
5/
1
8
/
2
0
1
8
8
:
2
1
:
4
3
A
M
ARCHITECTURAL
ROOF DETAILS
NLS
7T
H
S
O
U
T
H
2
N
D
E
A
S
T
R
E
X
B
U
R
G
,
I
D
A
H
O
TH
E
C
H
U
R
C
H
O
F
J
E
S
U
S
C
H
R
I
S
T
O
F
L
A
T
T
E
R
D
A
Y
S
A
I
N
T
S
14134.02
05.11.18
Re
x
b
u
r
g
I
d
a
h
o
T
e
m
p
l
e
P
a
r
a
p
e
t
&
R
o
o
f
Construction
Documentation
A523
BP
A523
A4 PARAPET CAP DETAIL EXISTING
A523
A5 PARAPET CAP DETAIL NEW
1 1/2" = 1'-0"A523
B3 ROOF CANOPY DETAIL EXISTING
1 1/2" = 1'-0"A523
B5 ROOF CANOPY DETAIL NEW
# Date Revision
A523
A3 TYPICAL TERMINATION BAR DETAIL NEW
A523
A1 TYPICAL TERMINATION BAR DETAIL EXISTING
FOR REFRENCE ONLY
FOR REFRENCE ONLY