HomeMy WebLinkAboutRESCHECK - 18-00169 - 320 Baldwin Dr - SFRREScheck Software Version 4.6.2 Compliance Certificate Project F56B5 - Logan Energy Code: 2015 IECC Location: Rexburg, Idaho Construction Type: Single-family Project Type: New Construction Orientation: Bldg. faces 45 deg. from North Conditioned Floor Area: 3,530 ft2 Glazing Area 19% Climate Zone: 6 (8693 HDD) Permit Date: Permit Number: 6 Construction Site: Owner/Agent: 1130 John hancook 0.056 founder's square subd. 488 Rexburg, ID 83440 0.0 /&-00161 Designer/Contractor: Kartchner Homes John@kartchnerhomes.com 'Compliance: Passes using UA trade-off; Compliance: 1.4% Better Than Code Maximum UA: 284 Your UA: 280 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies Ceiling 1: Flat Ceiling or Scissor Truss Main Level - Front: Wood Frame, 16" o.c. Orientation: Front Window 1: Vinyl/Fiberglass Frame:Double Pane with Low -E Orientation: Front Door 1: Solid Orientation: Front Main Level - Right: Wood Frame, 16" o.c. Orientation: Right side Main Level - Rear: Wood Frame, 16" o.c. Orientation: Back Window 1: Vinyl/Fiberglass Frame:Double Pane with Low -E Orientation: Back Main Level - Right: Wood Frame, 16" o.c. Orientation: Left side Basement Wall 1: Solid Concrete or Masonry Orientation: Front Wall height: 8.0' Depth below grade: 8.0' Insulation depth: 8.0' Window 4: Vinyl/Fiberglass Frame:Double Pane with Low -E Orientation: Front 1,765 50.0 0.0 0.026 4b 608 22.0 0.0 0.056 27 90 0.320 29 40 0.150 6 175 22.0 0.0 0.056 10 488 22.0 0.0 0.056 22 99 0.320 32 278 22.0 0.0 0.056 16 608 0.0 15.0 0.042 25 20 0.320 6 Project Title: FS6B5 - Logan Report date: 03/27/18 Data filename: C:\Users\jhoel lei n. MAI N\Documents\REScheck\Test\FS6b5 - jamestown.rck Page 1 of 10 Basement Wall 2: Solid Concrete or Masonry 175 0.0 15.0 0.042 7 Orientation: Right side Wall height: 8.0' Depth below grade: 8.0' Insulation depth: 8.0' Basement Wall 3: Solid Concrete or Masonry 488 0.0 15.0 0.042 18 Orientation: Back Wall height: 8.0' Depth below grade: 8.0' Insulation depth: 8.0' Window 5: Vinyl/Fiberglass Frame:Double Pane with Low -E 60 0.320 19 Orientation: Back Basement Wall 4: Solid Concrete or Masonry 278 0.0 15.0 0.042 11 Orientation: Left side Wall height: 8.0' Depth below grade: 8.0' Insulation depth: 8.0' Window 6: Vinyl/Fiberglass Frame:Double Pane with Low -E 20 0.320 6 Orientation: Left side Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date Project Title: FS665 - Logan Report date: 03/27/18 Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\Test\FS6b5-jamestown.rck Page 2 of 10 REScheck Software Version 4.6.2 CY(i Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Pre-Inspection/Plan Review Plans Verified Field Verified Value Complies? Comments/Assumptions Value & Req ID ❑Complies 103.1, ;Construction drawings and ❑Does Not 103.2 documentation demonstrate [PR1]1 energy code compliance for the ❑Not Observable 'building envelope. Thermal ❑Not Applicable :envelope represented on construction documents. 103.1, lConstruction drawings and ❑Complies ❑Does Not 103.2, documentation demonstrate 403.7 ;energy code compliance for ❑Not Observable [PR3]1 ;lighting and mechanical systems. ❑Not Applicable Systems serving multiple - dwelling units must demonstrate compliance with the IECC 'Commercial Provisions. 302.1, ,Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 `sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable - Manual J or other methods Btu/hr Btu/hr Applicable approved by the code official.❑Not Additional Comments/Assumptions: 111 High Impact (Tier 1) 2 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: FS665 - Logan Report date: 03/27/18 Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\Test\FS6b5 - jamestown.rck Page 3 of 10 Section # Plans Verified Foundation Inspection Field Verified F Complies? Comments/Assumptions Value Value & Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies ;See the Envelope Assemblies table for values. [F04]1 insulation R -value. Where interior R- R - ❑Does Not ;insulation is used, verification ❑Not Observable - may need to occur during ❑Not Applicable Insulation Inspection. Not required in warm -humid locations: in Climate Zone 3. 303.2 ;Conditioned basement wall ❑Complies [F05]1 'insulation installed per ❑Does Not :manufacturer's instructions. ❑Not Observable '. ❑Not Applicable 402.2.9 ;Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies ❑Does table for values. [F06]1 insulation depth of burial or Not distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 'A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a ❑Not Observable - :minimum of 6 in. below grade. ❑Not Applicable 403.9 'Snow- and ice -melting system ❑Complies [FO12]2 :controls installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: FS6B5 - Logan Report date: 03/27/18 Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\Test\FS6b5 - jamestown.rck Page 4 of 10 Section Plans Verified Field Verified Complies? Comments/Assumptions # Framing / Rough-In Inspection Value Value & Req.ID U ❑Complies See the Envelope Assemblies 402.1.1, Door U-factor. U- ❑Does Not table for values. 402.3.4 [FRI]1 ❑Not Observable ` ❑Not Applicable 402.1.1, Glazing U factor (area weighted U- U- ❑Complies `.See the Envelope Assemblies ;table for values. ❑Does Not 4 02.3.1, average). 402.3.3, ❑Not Observable 402.3.6,❑Not Applicable 402.5 [FR2]1 3013.1.3 U-factors of fenestration products ❑Complies ❑Does Not; [FR4]1 pare determined in accordance ;with the NFRC test procedure or []Not Observable taken from the default table. ❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier ❑Complies ❑Does Not [FR23]1 installed per manufacturer's instructions. ❑Not Observable _ ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies ❑Does Not [FR20]1 ' is listed and labeled as meeting iAAMA /WDMA/CSA 101/l.S.2/A440 ❑Not Observable ` - ;or has infiltration rates per NFRC ❑Not Applicable E 400 that do not exceed code t limits. 402.4.5 IC-rated recessed lighting fixtures. ❑Complies ❑Does Not [FR16]2 'sealed at housing/interior finish ,and labeled to indicate :52.0 cfm ❑Not Observable leakage at 75 Pa. ❑Not Applicable 403.2.1 ;Supply and return ducts in attics 'insulated ❑Complies ❑Does Not [FR12]1 >= R-8 where duct is >= 3 inches in diameter and >_ ❑Not Observable = R-6 where < 3 inches. Supply and ❑Not Applicable 3return ducts in other portions of .the building insulated >= R-6 for ! E ;diameter >= 3 inches and R-4.2 'for < 3 inches in diameter. 403.3.3.5 ;Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable - ❑Not Applicable 403.4 HVAC piping conveying fluids R- 'above R-❑Complies i Not [FR17]2 105 °F or chilled fluids❑Does below 55 °F are insulated to >_R ❑Not Observable ` 3 ❑Not Applicable 403.4.1 !Protection of insulation on HVAC ❑Complies i ❑Does Not [FR24]1 :piping. ❑Not Observable ; ❑Not Applicable 403.5.3 i Hot water pipes are insulated to R- R- ❑Complies E ❑Does Not ; [FR18]2:>_R-3. ❑Not Observable ❑Not Applicable- pplicable403.6 403.6 Automatic or gravity dampers are: ❑Complies ❑Does Not [FR19]2 'installed on all outdoor air !intakes and exhausts. ❑Not Observable ❑Not Applicable 11 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: FS665 - Logan Report date: 03/27/18 Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\Test\FS6b5 - jamestown.rck Page 5 of 10 Additional Comments/Assumptions: 1 JHigh Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: FS6135 - Logan Report date: 03/27/18 Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\Test\FS6b5-jamestown.rck Page 6 of 10 Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: FS6135 - Logan Report date: 03/27/18 Data filename: C:\Users\jhoeIlein.MAIN\Documents\REScheck\Test\FS6b5 - jamestown.rck Page 7 of 10 Inspection Plans Verified Field Verified -T Complies? - Comments/Assumptions Section # Insulation Value Value & Req.ID 303.1 `All installed insulation is labeled ❑Complies ❑Does Not [IN13]2 =or the installed R -values ;provided. ❑Not Observable - []Not Applicable 402.1.1, i Wall insulation R -value. If this is a ! R- R `❑Complies see the Envelope Assemblies ❑Does Not 'table for values. 402.2.5, mass wall with at least 1/2 of the F-1Wood 1771Wood 402.2.6 wall insulation on the wall ❑Mass E]Mass []Not Observable [I1\13]1 exterior, the exterior insulation ❑ Steel ❑ Steel ❑Not Applicable requirement applies (FR10). 303.2 ;Wall insulation is installed per ❑Complies ❑Does Not [IN4]1 :manufacturer's instructions. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: FS6135 - Logan Report date: 03/27/18 Data filename: C:\Users\jhoeIlein.MAIN\Documents\REScheck\Test\FS6b5 - jamestown.rck Page 7 of 10 Section # Final Inspection Provisions Plans Verified Value Field Verified Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R -value. R- R- ❑Complies :See the Envelope Assemblies 402.2.1, F-1Wood F1 wood ❑Does Not Mable for values. 402.2.2, ❑ Steel ❑ Steel EJ Observable 402.2.6 Applicable [FI1]1❑Not 303.1.1.1, ;Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every Observable 300 ftp.❑Not ❑Not Applicable 402.2.3 'Vented attics with air permeable ❑Complies [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that [:]Not Observable ,extends over insulation. ❑Not Applicable 402.2.4 ;Attic access hatch and door R- R- ❑Complies [F13]1 insulation >_R -value of the ❑Does Not ;adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 ' Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies IF11711 each in Climate Zones 1-2, and ❑Does Not <<=3 ach in Climate Zones 3-8. ❑Not Observable ` ❑Not Applicable 403.2.3 Duct tightness test result of <=4 cfm/100 cfm/100 ❑Complies [F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not E z<=3 cfm/100 ft2 without air []Not Observable handler @ 25 Pa. For rough -in ❑Not Applicable 'tests, verification may need to ,occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]1 'determine air leakage with ft2 ft2 ❑Does Not ,either: Rough -in test: Total ❑Not Observable ;leakage measured with a ❑Not Applicable pressure differential of 0.1 inch w.g. across the system including ;the manufacturer's air handler enclosure if installed at time of ;test. Postconstruction test: Total ,leakage measured with a pressure differential of 0.1 inch ;w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 ;Air handler leakage designated ❑Complies [F124]1 by manufacturer at <=2% of ❑Does Not :design airflow. ❑Not Observable ❑Not Applicable 403.1.1 ';Programmable thermostats ❑Complies [Flg]2 installed for control of primary ❑Does Not ;heating and cooling systems and ❑Not Observable initially set by manufacturer to E ❑Not Applicable code specifications. 403.1.2 ;Heat pump thermostat installed ❑Complies [FI10]2 'on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 'Circulating service hot water ❑Complies [Fl 1112 systems have automatic or ❑Does Not ,accessible manual controls. ❑Not Observable ❑Not Applicable 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: FS6135 - Logan Report date: 03/27/18 Data filename: C:\Users\jhoeIlei n. MAI N\Documents\REScheck\Test\FS6b5 -jamestown.rck Page 8 of 10 111 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: FS6135 - Logan Report date: 03/27/18 Data filename: C:\Users\jhoeIlein.MAIN\Documents\REScheck\Test\FS6b5-jamestown.rck Page 9 of 10 Plans Verified Provisions Field Verified Complies? Comments/Assumptions Section # Final Inspection Value Value & Req.ID ❑Complies 403.6.1 'All mechanical ventilation system ❑Does Not [F125]2 fans not part of tested and listed HVAC equipment meet efficacy []Not Observable and air flow limits. ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies ❑Does Not [F126]2 Ahrough one- or two -pipe heating ,systems have outdoor setback ❑Not Observable 'control to lower boiler water ❑Not Applicable ;temperature based on outdoor temperature. ❑Complies 403.5.1.1 '.Heated water circulation systems ❑Does Not [F128]2 have a circulation pump. The ;system return pipe is a dedicated ❑Not Observable , return pipe or a cold water supply ❑Not Applicable pipe. Gravity and thermos - ;syphon circulation systems are ;not present. Controls for circulating hot water system ;pumps start the pump with signal ;for hot water demand within the ;occupancy. Controls automatically turn off the pump ',when water is in circulation loop is at set -point temperature and no demand for hot water exists. 403.5.1.2 ;Electric heat trace systems ❑Complies ❑Does Not [F129]2 'comply with IEEE 515.1 or UL ;515. Controls automatically ❑Not Observable :adjust the energy input to the ❑Not Applicable -heat tracing to maintain the desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies ❑Does Not [F130]2 have recirculation pumps that pump water from a heated water ❑Not Observable supply pipe back to the heated ❑Not Applicable water source through a cold =water supply pipe have a ,demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 403.5.4 Drain water heat recovery units ❑Complies ❑Does Not [FI31]2 tested in accordance with CSA 1355.1. Potable water -side ❑Not Observable ,,pressure loss of drain water heat ❑Not Applicable ;recovery units < 3 psi for individual units connected to one !or two showers. Potable water- side pressure loss of drain water , ?heat recovery units < 2 psi for individual units connected to :three or more showers. 404.1 ;75% of lamps in permanent ❑Complies []Does Not [FI6]1 fixtures or 75% of permanent fixtures have high efficacy lamps. []Not Observable ,Does not apply to low -voltage ❑Not Applicable lighting. 404.1.1 Fuel gas lighting systems have ❑Complies ❑Does Not [FI23]3 no continuous pilot light. ❑Not Observable ❑Not Applicable 111 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: FS6135 - Logan Report date: 03/27/18 Data filename: C:\Users\jhoeIlein.MAIN\Documents\REScheck\Test\FS6b5-jamestown.rck Page 9 of 10 Section # & Req ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies? Comments/Assumptions 401.3 ;Compliance certificate posted. ❑Complies [F17 ]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [F118 ]3 ,mechanical and water heating ❑Does Not ;systems have been provided. []Not Observable F ❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: F56135 - Logan Report date: 03/27/18 Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\Test\FS6b5 -jamestown.rck Page 10 of 10 2015 IECC Energy Efficiency Certificate Above -Grade Wall 22.00 Below -Grade Wall 15.00 Floor 0.00 Ceiling / Roof 50.00 Ductwork (unconditioned spaces): Window 0.32 Door 0.15 Heating System: Cooling System: Water Heater: Name: Date: Comments