HomeMy WebLinkAboutPRODUCT INFO - 17-00798 - 2211 W 1000 S - Burton Elementary AdditionFeatures TrueAlarm analog sensing provides:  Digital transmission of analog sensor values via IDNet or MAPNET II two-wire communications For use with the following Simplex® products:  4007ES, 4010, 4010ES, 4100ES, and 4100U Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details)  4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation Fire alarm control panel provides:  Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection  Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity  Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot  Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors provide:  Seven levels of sensitivity from 0.2% to 3.7% (refer to additional information on page 3) Heat sensors provide:  Three fixed temperature sensing thresholds: 135° F, 155° F and 190° F  Rate-of-rise temperature sensing  Utility temperature sensing  Listed to UL 521 and ULC-S530 General features:  Operation is for ceiling or wall mounting  Listed to UL 268 and ULC-S529  Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted  Designed for EMI compatibility  Magnetic test feature is provided  Different bases are available to support a supervised or unsupervised output relay, and/or a remote LED alarm indicator Additional base reference:  For isolator bases, refer to data sheet S4098-0025  For sounder bases, refer to data sheet S4098-0028  For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7272-0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document. Accepted for use – City of New York Department of Buildings – MEA35-93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor’s present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor’s average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base’s LED pulses to indicate communications with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base’s LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensors – Photoelectric MEA (NYC) Acceptance* and Heat; Standard Bases and Accessories S4098-0019-23 8/2017 ALARM Sensor Base Features Base mounted address selection:  Address remains with its programmed location  Accessible from front (DIP switch under sensor) General features:  Automatic identification provides default sensitivity when substituting sensor types  Integral red LED for power-on (pulsing), or alarm or trouble (steady on)  Locking anti-tamper design mounts on standard outlet box  Magnetically operated functional test Sensor Bases 4098-9792, Standard Sensor Base 4098-9789, Sensor Base with wired connections for:  2098-9808 Remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Supervised Relay Bases (not compatible with 2120 CDT):  4098-9791, 4-Wire Sensor Base, use with remote or locally mounted 2098-9737 relay, requires separate 24 VDC  4098-9780, 2-Wire Sensor Base, use with remote or locally mounted 4098-9860 relay, no separate power required  Supervised relay operation is programmable and can be manually operated from control panel  Includes wired connections for remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Sensor Base Options 2098-9737, Remote or local mount supervised relay:  DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @ 28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9860, Remote or local mount supervised relay:  SPDT dry contacts, power limited rating of 2 A @ 30 VDC, resistive; non-power limited rating of 0.5 A @ 125 VAC, resistive 4098-9822, LED Annunciation Relay:  Activates when base LED is on steady, indicating local alarm or trouble  DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate:  Required for surface or semi-flush mounting to 4” square electrical box and for surface mounting to 4” octagonal box  Can be used for cosmetic retrofitting to existing 6-3/8” diameter base product 2098-9808, Remote red LED Alarm Indicator:  Mounts on single gang box (shown in illustration to right) Description TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor’s output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. Mounting Reference Electrical Box Requirements: (boxes are by others) Without relay in the box:4" octagonal or 4" square, 1-1/2" deep; single gang, 2" deep With relay in the box :4" octagonal or 4" square, 1-1/2" deep, with 1-1/2" extension ring TrueAlarm Bases 4098-9780, 4098-9789, 4098-9791, & 4098-9792 4-7/8" (124 mm) 15/16" (24 mm) 6-3/8" (162 mm) 1/4" (6.4 mm) 4098-9832 Adapter Plate, required for mounting to surface mounted boxes and 4"square flush box 2098-9737 Supervised Relay (mounts in base electrical box or remotely) 4098-9822 Relay (mounts in base electrical box) NOTE:Review total wire count, wire size, and accessories being wired to determine required box volume. Relay Size: 2-1/2" X 1-1/2" X 1" (3.75 in3 ) (64 mm X 38 mm X 25.4 mm) 4098-9860 Supervised Relay (mounts in base electrical box or remotely; 2-3/8" X 1-1/4" X 11/32" (1 in3 ) (60.4 mm X 31.8 mm X 8.6 mm) Surface mount reference 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess 1-1/2" (38 mm) minimum box depth 2 S4098-0019-23 8/2017 TrueAlarm Sensor Bases and Accessories TrueAlarm Sensors Features Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors:  Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation  Rated spacing distance between sensors: Fixed Temp. Setting UL & ULC Spacing FM Spacing, Either Fixed Temperature Setting 135° F / 190° F* (57.2° C / 88° C) 60 ft x 60 ft (18.3 m) 20 ft x 20 ft (6.1 m) for fixed temperature only; RTI = Quick 50 ft x 50 ft (15.2 m) for fixed temperature with either rate-of-rise selection; RTI = Ultra Fast 155° F (68° C) 40 ft x 40 ft (12.2 m) *Note: 190° F (88° C) ratings apply only to the 4098-9734 sensor. Smoke Sensors:  Photoelectric technology sensing  360° smoke entry for optimum response  Built-in insect screens 4098-9714 Photoelectric Sensor TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, 3.0%, and 3.7%. Application type and sensitivity are selected and then monitored at the fire alarm control panel.* The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. 2-1/8" (54 mm) LED status indicator 4-7/8" (124 mm) 4098-9714 Photoelectric Sensor with Base 4098-9733 and 4098-9734 Heat Sensors TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° C). The 4098-9734 sensor provides an additional 190° F (88° C) set point. In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° C). This feature can provide freeze warnings or alert to HVAC system problems. Refer to specific panels for availability. 2-3/8" (60 mm) LED status indicator 4-7/8" (124 mm) 4098-9733 Heat Sensor with Base 4098-9734 High Temperature Heat Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. Application Reference Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide.* * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 3 S4098-0019-23 8/2017 TrueAlarm Sensor Bases (for use with Sensors 4098-9714 and 4098-9733) (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model* Color Description Compatibility Mounting Requirements 4098-9792 White Standard Sensor Base No options 4” octagonal or 4” square box, 1-1/2” min. depth; or single gang box, 2” min. depth 4098-9776 Black 4098-9789 White Sensor Base with connections for Remote LED Alarm Indicator or Unsupervised Relay 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay 4” octagonal or 4” square box Note: Box depth requirements depend on total wire count and wire size, refer to accessories list below for reference. ** NOTE: 4098-9791 and 4098- 9780 are NOT compatible with the 2120 CDT 4098-9789 IND White 4098-9775 Black 4098-9791** White 4-Wire Sensor Supervised Relay Base with connections for LED Indicator or Unsupervised Relay 2098-9737 Supervised Remote Relay 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay 4098-9780** White 2-Wire Sensor Supervised Relay Base with connections for LED Indicator or Unsupervised Relay 4098-9860 Supervised Remote Relay 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay TrueAlarm Sensors Model* Model* Description Compatibility Mounting Requirements 4098-9714 White Photoelectric Smoke Sensor Bases 4098-9775, 4098-9776, 4098-9792, 4098-9789, 4098-9791, and 4098-9780 Refer to base requirements 4098-9714 IND 4098-9774 Black 4098-9733 White Heat Sensor 4098-9734 White High Temperature Heat Sensor TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements 2098-9737 Supervised Relay, mounts remote or in base electrical box For use with 4098-9791 base Remote Mounting requires 4” octagonal or 4” square box, 1-1/2” minimum depth Base Mounting requires 4” octagonal box, 2- 1/8” deep with 1-1/2” extension ring 4098-9860 Supervised Relay, mounts remote or in base electrical box For use with 4098-9780 base 2098-9808 Remote Red LED Alarm Indicator on single gang stainless steel plate Bases 4098-9789, 4098-9791, and 4098- 9780 Single gang box, 1-1/2” minimum depth 4098-9822 Unsupervised Relay, tracks base LED status; Note: Mounts only in base electrical box Bases 4098-9789, 4098-9791, and 4098- 9780 4” octagonal box, 2-1/8” deep with 1-1/2” extension ring 4098-9832 Adapter Plate Bases 4098-9792, 4098-9789, 4098-9791, and 4098-9780 Required for surface or semi-flush mounted 4” square box and for surface mounted 4” octagonal box * Note: Model numbers ending in IND are assembled in India. SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Westminster, MA • 01441-0001 • USA S4098-0019-23 8/2017 www.simplex-fire.com © 2017 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. General Operating Specifications Communications and Sensor Supervisory Power IDNet or MAPNET II communications, auto-selected, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mm2 ) UL Listed Operating Temperature Range 32° to 100° F (0° to 38° C) Operating Temperature Range with 4098-9733 Heat Sensor 32° to 122° F (0° to 50° C) with 4098-9714 Smoke Sensor 15° to 122° F (-9° to 50° C) With 4098-9734 Heat Sensor 32° to 150° F (0° to 66° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10 to 95% RH 4098-9714 Smoke Sensor Air Velocity Rating 0-4000 ft/min (0-1220 m/min) Housing Color Frost White or Black 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 A, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9780 Base With Supervised Remote Relay 4098-9860 (see page 2 for contact ratings) Power Supplied from communications 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789. 4098-9791, and 4098-9780 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply TrueAlarm Analog Sensing Product Selection Chart Specifications Features Audible/visible (A/V) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount  Operation is compatible with ADA requirements (refer to important installation information on page 3)  Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Operates over a two-wire SmartSync circuit to provide:  Horns that are controlled separately from strobes on the same two-wire circuit  “On-until-silenced” and “on-until-reset” operation on the same two-wire pair  SmartSync horn activation of Temporal pattern, March Time pattern (at 60 BPM), or on continuously  Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate  Class B operation requires connection to a compatible SmartSync NAC or to SmartSync Control Module (SCM) 4905-9938  Class A operation when connected to the 4905-9938 SCM or with 4100U series fire alarm control panel NACs Wall mount A/Vs features:  Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing  Covers are available separately to convert housing color  Available UL listed sound damper for locations requiring attenuation of 5 to 6 dBA (stairwells, small rooms, highly reverberant areas, etc.) Optional adapters and wire guards:  Wall mount A/V adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes  UL listed red wire guards are available for wall or ceiling mount A/Vs Visible notification appliance (strobe):  24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing  UL listed to Standard 1971  Regulated circuit design ensures consistent flash output and provides controlled inrush current Audible notification appliance (horn):  Low current, 24 VDC electronic horn with harmonically rich sound output suitable for either steady or coded operation (Temporal or 60 BPM March Time pattern)  UL listed to Standard 464 Wall and Ceiling Mount A/Vs Description Multi-Candela TrueAlert A/Vs with horn and synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount A/V housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4” square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount A/Vs install using standard 4” electrical boxes. Color choice is determined by model number. Strobe Intensity Selection During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:317 for allowable values and/or conditions concerning material presented in this document. Accepted for use – City of New York Department of Buildings – MEA35-93E. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; SmartSync Operation Audible/Visible Notification MEA (NYC) Acceptance* with Horn and Synchronized Flash, Non-Addressable S4906-0002-6 11/2014 Strobe Application Selection Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). Synchronized Strobes Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these A/Vs are synchronized by the controlling SmartSync operation NAC. SmartSync Two-Wire Control SmartSync operation mode allows a two-wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing. The horn operates as “on-until-silenced” while the strobe operation is “on-until-reset.” SmartSync Control Sources  4006, 4007ES Hybrid, 4008, 4010, 4010ES, 4100ES, and 4100U Fire Alarm Control Panels (refer to individual product data sheets for more information)  4009 IDNet NAC Extender (refer to data sheet S4009-0002)  SmartSync Control Module (SCM) 4905-9938 (refer to data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. 2 S4906-0002-6 11/2014 Multi-Candela A/Vs Model Mounting Housing Color “FIRE” Lettering Description 4906-9127 Wall Red White Horn with Multi-Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with SmartSync two-wire control 4906-9129 White Red 4906-9128 Ceiling Red White 4906-9130 White Red Wall Mount A/V Accessories Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2” (38 mm) deep surface mounted boxes 5-3/8” H x 5-1/4” W x 1-5/8” D (136 mm x 133 mm x 41 mm) depth with strobe = 4-3/8” (111 mm) 4905-9940 White 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for retrofit, may be mounted vertical or horizontal) 8-5/16” x 5-3/4” x 0.060” Thick (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) 4905-9838 Optional Sound Damper; package of 20; field installed adhesive backed horn output attenuator; reduces output 5 to 6 dBA NOTE: After Sound Damper installation, measure sound level to ensure compliance with applicable code requirements 1-3/4” Diameter (44.5 mm) with 0.31” (8 mm) sound opening SmartSync Control Module Model Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4” (102 mm) square box; refer to data sheet S4905-0003 for details 4” x 4-1/8” x 1-1/4” D (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount A/Vs Model Description Dimensions 4905-9994 Red cover with white “FIRE” lettering 5-1/8” H x 5” W x 1-1/2” D (130 mm x 127 mm x 38 mm) 4905-9995 White cover with red “FIRE” lettering Wire Guards and Ceiling Mount A/V Adapter Model Description Dimensions 4905-9961* Wall mount red wire guard with mounting plate, compatible with semi-flush or surface mounted boxes 6-1/16” H x 6-1/16” W x 3-1/8” D (154 mm x 154 mm x 79 mm) 4905-9927* Ceiling Mount Red Wire Guard for mounting to flush mounted electrical box 8-1/2” x 6-1/8” x 3” (216 mm x 156 mm x 76 mm) 4905-9928* Red Adapter Plate, required to mount guard to surface mounted electrical box 9” x 7” (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension, use to cover 1-1/2” deep surface mounted boxes 4-3/4" x 6-7/8" x 1-1/2" deep, (121 mm x 175 mm x 38 mm) 4905-9916 Red * UL listed by Space Age Electronics Inc. Product Selection 3 S4906-0002-6 11/2014 Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 DC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Horn Output Ratings @ 10 ft (3 m) (see Note 2) Voltage 16 VDC 24 VDC 33 VDC Sound Type (see Note 2) Steady Coded Steady Coded Steady Coded UL 464 Reverberant Chamber 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Wall Mount Housing Dimensions (with lens) 5-1/8” H x 5” W x 2-3/4” D (130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 cd 30 cd 75 cd 110 cd 75 mA 116 mA 221 mA 285 mA Reference RMS Currents at other voltages 18 VDC 67 mA 103 mA 196 mA 253 mA 24 VDC 50 mA 77 mA 147 mA 190 mA Ceiling Mount Housing Dimensions (with lens) 4-3/4 L” x 6-7/8” W x 2-5/8” D (121 mm x 175 mm x 67 mm) Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 cd 30 cd 75 cd 110 cd 86 mA 132 mA 250 mA 320 mA Reference RMS Currents at other voltages 18 VDC 76 mA 117 mA 222 mA 284 mA 24 VDC 57 mA 88 mA 167 mA 213 mA NOTES: 1. “Regulated 24 DC” refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a “fast” setting. Under the same test conditions, coded horn output “peak” sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output. 3. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Removable cover (tool required) Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 1-1/2" (38 mm) deep, by others 2 1 34 Mounting Holes: 4" square (4) Single gang (2) Double gang (3) Wiring access hole Wiring terminals for SmartSync operation Transparent housing and lens assembly Strobe intensity viewing slot Intensity selection plug, accessible only from rear of housing; factory setting is 15 cd 110753015 Optional 4905-9838Sound Damper, field attached to attenuate sound 5 to 6 dBA a NFPA 72 requires that the entire lens be not less than 80" and not greater than 96" above the finished floor Electrical box outline 80" (2.03 m) minimum Bottom of lens is either even with, or slightly above bottom of compatible boxes IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Installation Reference, Surface or Semi-Flush Mounting A/V Specifications Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard 2975-9145 Box 4905-9931 Adapter Plate 4905-9961 Optional Wire Guard (shown here for reference only, can be used on other mounting options) 4905-9931 Adapter Plate 4" (102 mm) square box profile, 1-1/2" (38 mm) deep Surface mount conduit and box shown for reference A/V Optional 4905-9961 Wire Guard Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) 11 0 75 30 15 4" (102 mm) square box, 1-1/2" (38 mm) minimum depth Optional 4905-9915/-9916 Adapter, recommended for surface mounted box Wiring terminals are located behind the housing Ceiling reference, surface mounted box Ceiling reference, flush mounted box Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd Optional 4905-9928 Adapter Plate, required for surface mounted electrical box Optional 4905-9927 Red Wire Guard Four mounting clamps included, two each side End View TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S4906-0002-6 11/2014 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Ceiling Mount A/V and Guard Installation Reference Features Weatherproof 24 VDC notification appliances for extended temperature and extended humidity operation:  NEMA 3R rated enclosure with ratings for indoor or outdoor applications  Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens  Red housings are for indoor or outdoor applications and provide UV light stable color  White housings are for indoor applications with limited UV light exposure  Mounting is to matching weatherproof boxes (required), ordered separately  Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Agency listings reference:  UL listed to Standard 1638 for outdoor applications with strobe rated at 75 cd (WP75)  UL listed to Standard 1971 for indoor applications with strobe intensity selectable as 15, 60, or 75 candela; indoor applications are compatible with ADA requirements (refer to important installation information on page 4)  Separate models are ULC listed to Standard S526 (strobes) and S525 (horns) for outdoor applications with strobe intensity selectable as 5, 20, or 30 candela (available in red only) Operation details:  A visible intensity selection jumper is secured behind the strobe housing  Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC)  Regulated circuit design ensures consistent flash output and provides controlled inrush current  A/V appliances have an efficient electronic horn Synchronized strobe compatibility:  Simplex® fire alarm control panels and NAC Extenders when selected to provide strobe synchronization or SmartSync two-wire control  Separate strobe Synchronization Modules or SmartSync Control Modules (SCMs) that convert conventional NAC inputs to a Smartsync output SmartSync two-wire operation provides:  Horns controlled separately from strobes on the same two-wire circuit, activated as Temporal pattern, March Time pattern (at 60 BPM), or on continuously Weatherproof A/V (top) and Strobe (middle), side view of A/V on Weatherproof Mounting Boxes (bottom) Description Weatherproof multi-candela TrueAlert appliances provide V/O and A/V SmartSync operation for indoor and outdoor, extended temperature and extended humidity applications. The enclosures are impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Strobe Intensity Selection During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a yellow background allows the selected intensity to be seen at the side of the strobe lens. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:331 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; Weatherproof Notification Appliances (non-addressable) FM Approved* Wall Mount Visible Only (V/O) and Audible/Visible (A/V) S4906-0010-6 11/2014 Strobe Application Reference Proper selection of weatherproof notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). Requirements may differ from indoor appliance applications, contact your local authority having jurisdiction (AHJ) to assist in determining requirements. SmartSync Two-Wire Control SmartSync operation mode allows a two-wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing. The horn operates as “on-until-silenced” while the strobe operation is “on-until-reset.” SmartSync Control Sources SmartSync two-wire control is available from:  4006, 4007ES Hybrid, 4008, 4010, 4010ES, 4100ES, and 4100U Fire Alarm Control Panels (refer to individual product data sheets for more information)  4009 IDNet NAC Extenders (refer to data sheet S4009-0002)  SmartSync Control Module (SCM) Model 4905-9938 (refer to data sheet S4905-0003)  Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. UL Listed TrueAlert Weatherproof Multi-Candela Notification Appliances Model Type Housing “FIRE” Lettering Description UL 1971 Intensity Rating UL 1638 Intensity Rating 4906-9105 Strobe (V/O) Red White UL listed weatherproof appliance with multi-candela strobe; requires weatherproof box below 15, 60, or 75 cd 75 cd (setting WP75) 4906-9106 White Red 4906-9131 Horn/Strobe (A/V) Red White 4906-9132 White Red ULC Listed TrueAlert Weatherproof Multi-Candela Notification Appliances Model Type Housing “FIRE” Lettering Description ULC Intensity Ratings 4906-9113 Strobe (V/O) Red White ULC listed weatherproof appliance with multi-candela strobe; requires weatherproof box below 5, 20, or 30 cd 4906-9143 Horn/Strobe (A/V) Wall Mount Weatherproof Boxes (Required) Model Description Dimensions 49WPBB-AVVOWR Red Surface Mount Weatherproof Mounting boxes 5 ½” H x 6 ⅛” W x 1 ⅝” D (140 mm x 156 mm x 41 mm) 4905-9829 White Aftermarket Red Bilingual (French/English) Covers (for field installation) Model Description 4905-9832 Red strobe (V/O) cover White “FEU/FIRE” lettering 4905-9833 Red horn/strobe (A/V) cover Synchronization Module Reference (refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with in/out 18 AWG (0.82 mm2) wire leads, rated for 2 A NAC, requires 10 mA for power 1 ⅜” x 2 7⁄16” x 13⁄16” (35 mm x 62 mm x 20 mm) 4905-9922 Class A 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4” (102 mm) square box 4” x 4 ⅛” x 1 ¼” D (102 mm x 105 mm x 32 mm) 2 S4906-0010-6 11/2014 Product Selection 3 S4906-0010-6 11/2014 Rated Voltage Range Regulated 24 VDC; see Note 1 below Flash Rate 1 Hz; up to 24 synchronized strobes maximum per NAC Temperature Range UL 1971 Listed Rating 32° to 122° F (0° to 50° C); selectable 15/30/75 cd UL 1638 Listed Rating -31°F to 150°F (-35° C to 66°C); 75 cd rating ULC S526 & S525 Listed Rating -40°F to 150°F (-40° C to 66°C); 5/20/30 cd rating Humidity Range UL 1971 Listed Rating 10% to 93%, at 100° F (38° C) UL 1638, ULC S526, & ULC S525 up to 98%, at 104 °F (40° C) Wiring Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Horn Output; Models 4906-9131, 4906-9132, & 4906-9143; UL & ULC Ratings as noted Output Sound Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Horn Output Ratings @ 10 ft (3 m) (see Note 2) Voltage 16 VDC 24 VDC 33 VDC Sound Type (see Note 2)Steady Coded Steady Coded Steady Coded UL 464 Reverberant Chamber 80 dBA 76 dBA 83 dBA 79 dBA 86 dBA 81 dBA ULC S525 Anechoic Chamber 96 dBA 96 dBA 99 dBA 99 dBA 101 dBA 101 dBA Maximum RMS Current Ratings (see Note 3 below) UL 1971 Ratings (32° F to 122° F) UL 1638 Ratings 75 cd (WP75) Model Intensity Selection/Temperature 15 cd 60 cd 75 cd 32° F to 150°F (0° C to 66°C) -31° F to below 32°F (-35° C to 0° C) V/O Models 4906-9105 & 4906-9106 77 mA 192 mA 231 mA 189 mA 273 mA A/V Models 4906-9131 & 4906-9132 91 mA 204 mA 249 mA 205 mA 277 mA ULC S526/S525 Ratings per Intensity Selection Model 5 cd 20 cd 30 cd V/O Model 4906-9113 115 mA 270 mA 295 mA A/V Model 4906-9143 125 mA 275 mA 322 mA NOTES: 1. “Regulated 24 VDC” refers to the voltage range of 16 to 33 VDC per UL 1971 and UL 1638. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a “fast” setting. Under the same test conditions, coded horn output “peak” sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output 3. Currents of A/Vs are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) 5-3/8" (137 mm) 4-1/2” (114 mm) 5-17/32" (140 mm) total height 5-9/16" (141 mm) between mounting holes 6-1/8" (156 mm) 1-21/32" (42 mm) 4-11/32" (110 mm) total depth 4905-9832 Strobe Cover (red) Optional Bilingual Covers (field installed) 4905-9833 A/V Cover (red) Specifications Dimension and Optional Cover Reference Weatherproof Appliance Installation Reference NOTE: For detailed installation information, refer to Installation Instructions 579-857 for UL listed products, and Installation Instructions 579-885 for ULC listed products. Housing (A/V shown) Standard cover (A/V shown) Weatherproof mounting box (required): 49WPBB-AVVOWR, Red; 4905-9829, White Perimeter gasket, pre-installed Knockouts top, bottom, sides, and back; 5 total Cover to mounting box mounting screws (3) 1 3 Housing to mounting box screws (2) Three (3) cover attachment tabs located bottom, left and right side Internal cover gasket is pre-installed Strobe intensity viewing slot Intensity selection plug, accessible only from rear of housing: UL Listed Models: Models 4906-9105, 4906-9106, 4906-9131, and 4906-9132 ; factory setting is WP75, the UL 1638, 75 cd rating ULC Listed Models: Models 4906-9113, 4906-9143 ; factory setting is 30 cd 30205 WP7575 60 15 Polar Light Dispersion Reference, Each Intensity Selection; Percent of Rated Light Output at 77° F (25° C) Vertical Dispersion Horizontal Dispersion Angle Below Axis UL 1971 Minimum Typical Output Angle from Axis UL 1971 Minimum Typical Output 0 100% 322% 0 100% 320% 5 90% 217% ±5 90% 214% 10 90% 168% ±10 90% 177% 15 90% 179% ±15 90% 175% 20 90% 210% ±20 90% 174% 25 90% 184% ±25 90% 170% 30 90% 149% ±30 75% 169% 35 65% 172% ±35 75% 157% 40 46% 189% ±40 75% 151% 45 34% 203% ±45 75% 138% 50 27% 152% ±50 55% 130% 55 22% 166% ±55 45% 121% 60 18% 166% ±60 40% 117% 65 16% 164% ±65 35% 109% 70 15% 163% ±70 35% 105% 75 13% 159% ±75 30% 98% 80 12% 138% ±80 30% 90% 85 12% 113% ±85 25% 78% 90 12% 88% ±90 25% 67% WP75 Intensity Selection Light Output Reference On- Axis Vertical, Below Axis Horizontal, Left/Right of Axis Angle 0° 45° 90° 45° 90° UL 1638 Minimum Candela Rating (over temperature range) 75 35 10 32 15 Typical Candela at 77° F (25° C) 215 103 24 94 39 2 A/V Sound Dispersion per ULC S525 (anechoic testing performed at 3 m (10 ft) Vertical Dispersion -1 dB bottom -9 dB top -6 dB @75° -3 dB @60° minimal loss on-axis (0°) rated output Horizontal Dispersion on-axis (0°) rated output -6 dB right side-6 dB left side -3 dB @65° -3 dB @75° -6 dB @85° top Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S4906-0010-6 11/2014 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA).