Loading...
HomeMy WebLinkAboutBUILD PLANS - 18-00220 - 297 E 7th N - Covey Cove - 4 PlexBRENT A. McFARLAND AR -2561 5-10-18 STATE OF IDAHO N 1E v -KJ rfD 00 W� 0 O 2 v FQ m O W N UO Q � r7 ® CO N O I w W U 0w O > mo < ,e C2-, U M 1E 1 7 1 1 17 CONSULTANTS: Go ID 0 0 V AREA MAP DRAWING INDEX a z DRAWING No. Q GENERAL >PROJECT SITE G1.1 COVER SHEET & INDEX TO DRAWINGS o Z x ju A S S O C I A T E S G1.2 GENERAL ACCESSIBILITY REQUIREMENTS v REXBURG, ID ju 0 z ----------------------------------- - ARCHITECTURAL 20 33 Q - - - - A1.1 MAIN & UPPER FLOOR PLANS Vju - ` =z DESIGN CRITERIA A1.2 FOOTING/FOUNDATION/ROOF PLANS ju A1.3 FLOOR FRAMING PLAN x REXBURG MADISON - A2.1 EXTERIOR ELEVATIONS COUNTY W 3RD N ST V AIRPORT MADISON b COUNTY —' 3 FAIRGROUNDS W 2nd N ST E 2nd N ST INA SEISMIC DESIGN CATEGORY D A3.1 BUILDING SECTIONS ANGflAs DR REXBURG CORSE G 3 EstNST GROUND SNOW LOAD 50 sf w �oHA � PAW � V E. MAIN ST. ROOF SNOW LOAD 35 sf 33 W MAIN ST. MAPLE W ist S ST UND WIND LOAD 9 0 s f NI DR AURUS DR� PORTER OFFICE ❑ tl sr I — N FROST DEPTH 36" %NQUYFN n 3 N N BYIF-IDAHO N � 3 3 UFUkE32.51Tf � � n COMMANCHE AVE N NI N N a h a y35DS RISK CATEGORY II y� a � .. oo � Lo w W A d <G il1 N N 'r," W 5th S ST `450 S o DRAWN BY: JOB NO: � r z JE 5th S' � �w N 580 S � � 87 �M a9 W stn S sT �` 750 w N 0* 20 ,000 s w stnFST N PO CHECKED BY: DATE: ARMORY BAM MAY ' 15 CREST °R REXBURG PLOT DATE: DRAWING NO. N RE: hIORTFI .I OF STANDARD ACCESSIBILITY: I. ALL DOORS IN THE PUBLIC AND COMMON USE AREAS SHALL COMPLY WITH ANSI A117.1. INCLUDING NECESSARY MANEUVERING CLEARANCES AND ACCESSIBLE DOOR HARDWARE. THIS INCLUDES THE EXTERIOR SIDE OF THE MAIN ENTRY DOORS TO DWELLING UNITS. 2. ALL DOORS SHALL HAVE 32' MIN. CLEAR WIDTH WHEN DOOR IS OPEN 90 DEGREES. 3. ALL PLUMBING FIXTURES AND APPLIANCES IN DWELLING UNITS SHALL HAVE MIN. 30' X 48' CLEAR FLOOR SPACE AS REQ'D BY FHA. 4. ALL PLUMBING FIXTURES, APPLIANCES #- TELEPHONES IN PUBLIC AND COMMON USE AREAS SHALL COMPLY WITH A.D.A., IBC AND ANSI 117.1 NOTE: GRAS BARS MUST NOT ROTATE WITHIN THEIR FITTINGS NOTE: FLUSH VALVE HANDLE ON WIDE SIDE OF TOILET, 44' AFF MAX. 39'-41' X 1 1/4' TO 1 1/2' O.D. 36' MAX. ao <X GRAB BAR (TYP.) 12' 3'-6' 36' MIN. MA . MIN. III 1 1/2' MIN. CLEAR TO WALL OR ro'MAXf DISPENSERS FIN. FLOOR, TYPICAL TOWEL DISPENSER TOWEL HAND WASTE RECEPTACLE DISPENSER DRYER NOTE: PROVIDE A MIN. CLEAR FLOOR SPACE OF 30X48 AT APPROACH, ALONG ?a AN ACCESSIBLE ROUTE. z� X _Nw nI- Z � Q� p� Z Z wAs�r r0 � � Q z Q C, M Q n Q •� X ;o r0 0 io 0 I N < FIN. FLOOR TYPICAL SANITARY WASTE TISSUE PRODUCTS RECEPTACLE DISPENSER NOTE: NOTE: 18' MIN. CLP PROVIDE A MIN. CLEAR FLOOR SPACE OF 30X48 WITH FROM WALL TO 19' MAX. EXTENDING UNDER LAV/D.F. TO INSULATED &- OF LAY PIPING/PLUMBING. NOTE: FAUCETS MUST BE LEVER TYPE, ELECTRONICALLY ACTIVATED, OR APPROVED SELF-CLOSING VALVES (MIN. 10 SEC. OPEN FLOW), AND B- OPERABLE W/ MOUNT SIGNS AT LATCH W/ONE HAND. NOT REQUIRING TIGHT GRASPING. SIDE OF DOOR, OR NEAREST PINCHING OR TWISTING OF WRIST. 5 Ib. MAX FORCE ADJACENT WALL REQUIRED TO ACTIVATE CONTROLS. INSULATE ALL 17' EXPOSED PIPES MIN. J �I z Q zr z w 0 Q❑ 18� w� X wo ? z, z_ z x I u_a� �<1 I� o°a w� o°ao wa �0r M MIN. ��' DO (O wa'� uy rQ'� Q0 M FQ QO M ' Z O W M O� �� N Qa0 MIN, KNEE N N mw N Qp z r 0 1 N O �E r CLEARANCE O f r FIN. FLOOR, FIN. FLOOR, 6' TYPICAL TYPICAL MAX. O CLEARANCE TOILET TOILET LAVATORY, MIRROR AND LAVATORY SOAP DISPENSER el c Ll - f FIN. FLOOR TYPICAL STANI:)ARI;� ACCESSIBILITY INSTALLATION REOU I REMENTS SCALE: N.T.S. CONTROL END ELEVATION I m lz m m BACK WALL ELEVATION V T1'P I GAL 6RAB BAR INSTALLATION REOU I REMENTS SCALE: N.T.S. UNOBSTRUCTED FORWARD REACH 17'-19' M MAX. r M. Z Q R 8' w •M � O 'AIN.O N ►A a DRINKING FOUNTAIN 24" MAX 24" MIN. 12" MAX BACK WALL PLAN OBSTRUCTED HIGH FORWARD REACH TYPICAL v PERMANENT ROOM SIGNAGE NAPKIN DISPOSAL VENDOR 30' MIN. CLP. WIDTH 1 18' cL- FIN. C R. 147 W LL 1 Ft I NOTES: 1. FLUSH VALVE HANDLE AT 44'AFF MAX. 2. 30' X 48' MIN. CLR FLR SPACE AT APPROACH 3. 5 Ib. MAX. FORCE TO OPERATE FLUSH VALVE 4.14' MIN. PROJECTION FROM WALL —FACE OF FINISHED WALL URINAL UNOBSTRUCTED SIDE REACH TYF I GAL CLEARANCE REOU I REMENTS SCALE: N.T.S. BRENT A. McFARLAND AR -2561 Q cSd Q�d Q w> � ui X z� ::E -j Q aW x o x �0 Qp x CT)m o X � N I Ucy) U) m aw 04 N o ® 704 Q nJ Q NJ Q a0a' m< N � OZ Y ;o;o00 00 o0 FIN. FLOOR, TYPICAL TOWEL DISPENSER TOWEL HAND WASTE RECEPTACLE DISPENSER DRYER NOTE: PROVIDE A MIN. CLEAR FLOOR SPACE OF 30X48 AT APPROACH, ALONG ?a AN ACCESSIBLE ROUTE. z� X _Nw nI- Z � Q� p� Z Z wAs�r r0 � � Q z Q C, M Q n Q •� X ;o r0 0 io 0 I N < FIN. FLOOR TYPICAL SANITARY WASTE TISSUE PRODUCTS RECEPTACLE DISPENSER NOTE: NOTE: 18' MIN. CLP PROVIDE A MIN. CLEAR FLOOR SPACE OF 30X48 WITH FROM WALL TO 19' MAX. EXTENDING UNDER LAV/D.F. TO INSULATED &- OF LAY PIPING/PLUMBING. NOTE: FAUCETS MUST BE LEVER TYPE, ELECTRONICALLY ACTIVATED, OR APPROVED SELF-CLOSING VALVES (MIN. 10 SEC. OPEN FLOW), AND B- OPERABLE W/ MOUNT SIGNS AT LATCH W/ONE HAND. NOT REQUIRING TIGHT GRASPING. SIDE OF DOOR, OR NEAREST PINCHING OR TWISTING OF WRIST. 5 Ib. MAX FORCE ADJACENT WALL REQUIRED TO ACTIVATE CONTROLS. INSULATE ALL 17' EXPOSED PIPES MIN. J �I z Q zr z w 0 Q❑ 18� w� X wo ? z, z_ z x I u_a� �<1 I� o°a w� o°ao wa �0r M MIN. ��' DO (O wa'� uy rQ'� Q0 M FQ QO M ' Z O W M O� �� N Qa0 MIN, KNEE N N mw N Qp z r 0 1 N O �E r CLEARANCE O f r FIN. FLOOR, FIN. FLOOR, 6' TYPICAL TYPICAL MAX. O CLEARANCE TOILET TOILET LAVATORY, MIRROR AND LAVATORY SOAP DISPENSER el c Ll - f FIN. FLOOR TYPICAL STANI:)ARI;� ACCESSIBILITY INSTALLATION REOU I REMENTS SCALE: N.T.S. CONTROL END ELEVATION I m lz m m BACK WALL ELEVATION V T1'P I GAL 6RAB BAR INSTALLATION REOU I REMENTS SCALE: N.T.S. UNOBSTRUCTED FORWARD REACH 17'-19' M MAX. r M. Z Q R 8' w •M � O 'AIN.O N ►A a DRINKING FOUNTAIN 24" MAX 24" MIN. 12" MAX BACK WALL PLAN OBSTRUCTED HIGH FORWARD REACH TYPICAL v PERMANENT ROOM SIGNAGE NAPKIN DISPOSAL VENDOR 30' MIN. CLP. WIDTH 1 18' cL- FIN. C R. 147 W LL 1 Ft I NOTES: 1. FLUSH VALVE HANDLE AT 44'AFF MAX. 2. 30' X 48' MIN. CLR FLR SPACE AT APPROACH 3. 5 Ib. MAX. FORCE TO OPERATE FLUSH VALVE 4.14' MIN. PROJECTION FROM WALL —FACE OF FINISHED WALL URINAL UNOBSTRUCTED SIDE REACH TYF I GAL CLEARANCE REOU I REMENTS SCALE: N.T.S. ELECTRICAL DEVICES OBSTRUCTED HIGH SIDE REACH GENERAL NOTES: 1. OWNERS WILL PROVIDE 2% TYPE A UNITS. 2. THE TYPE A UNITS WILL HAVE A REMOVABLE CABINET. I'll, MIN. GUI DANCE FOR KNEE SPAGES IN "B" BATHROOMS KNEE SPACE AT LAVATORIES 6UIDANCE FOR KNEE SPACES IN "A" BATHROOMS BRENT A. McFARLAND AR -2561 r Z STATE OF IDAHO W � X r C" N N Q Q x o x Qp x CT)m o X � N I Ucy) U) m 04 N o ® 704 I w w U v® 00 Z U oQ m< N � CONSULTANTS: Y WO �r ELECTRICAL DEVICES OBSTRUCTED HIGH SIDE REACH GENERAL NOTES: 1. OWNERS WILL PROVIDE 2% TYPE A UNITS. 2. THE TYPE A UNITS WILL HAVE A REMOVABLE CABINET. I'll, MIN. GUI DANCE FOR KNEE SPAGES IN "B" BATHROOMS KNEE SPACE AT LAVATORIES 6UIDANCE FOR KNEE SPACES IN "A" BATHROOMS BRENT A. McFARLAND AR -2561 5-10-18 STATE OF IDAHO C" N N coc Wco p o x o x Qp x CT)m o X � N I Ucy) U) m 04 N o ® 704 I w w U v® 00 Z U oQ m< N � CONSULTANTS: Y r � Q � O r ju O v� V � w � U Lu Z n C) ¢ of o REVISION: DRAWN BY: JOB NO: GDR '750 CHECKED BY: DATE: BA4M MAT' le? PLOT DATE: DRAWING NO. FILE: C71.2 OF w_ MAIN FLOOR PLAN SGALE: 1/4" = I' -O" UPPER FLOOR PLAN 5GALE: 1/4" = 1'-0 " EXTERIOR WALL MUST BE FIRE RATED ON BOTH SIDES WHERE UNITS ARE CLOSER THAN 10' APART NOTES O DASHED AREA REPRESENTS FHA CLEARANCE REG2U I REMENT. (MA I N FLOOR ONLY) I 4oiE� I I X� uR s/ � 5' LF APPLIANCES KITCHEN O2 ALL D I MENS I ONS ARE FROM FACE OF STUD (U.N.O.) O D I MEN51 ON ARE TYP I CAL ALL UNITS O DELETE WINDOW AHEN ADJACENT UNIT IS < 10'-0" O5 INSTALL 2X10 BACKING FOR ?ADAPTABLE 6RA5 BAR INSTALL 50 THAT CENTER OF BACKING 15 AT REG2U I RED HT. - SEE DRAAI NG 61.2 FOR GRAB BAR LOCATIONS ( ) L u BRENT A. McFARLAND AR -2561 5-10-18 STATE OF IDAHO I N 0N M M W00 00 O o S v o x � w cn rn m Lu N K U' ON" � W ZD O � O Z U o< m < N � L� CONSULTANTS: 1 Y a V 1 Z O Oz V lu O l O l9 w w � z o � o I REVISION: DRAWN BY. JOB NO: R5M 750 CHECKED BY: DATE: BAM MAY ' 18 PLOT DATE: 5-09-18 DRAWING NO. FILE: 750-A1.1-MFP * A1.1 ALI OF N m ELEV. 100'-O" 4" FREE DRAINING GRAVEL UNDER SLAB VAPOR BARRIER (BELOW 6RAVEL) ELEV. 97'-O" TOP OF FOOTING NV r.I 0. rfromrom VENTED ASPHAL SHINGLE ROOFIN LB BUILDING FEL RIDGE LINES SHo VENTED W/ MANUFACTURES RIDGE SHINGLE. P OF CONCRETE OTIN6 AT ELEVATION -0" (TYPICAL) FOOTINGS SHALL HAVE (2) #4 BAR CONTINUOUS WALLS SHALL HAVE #4 BAR 36" OC VERT. & (1) #4 TOP &BOTTOM HORIZONTAL FOOT I N67 4 FOUN=OAT I ON ROOF PLAN SCALE: 1/4" = 1'-0" 4'-O" 2" RI61D INSULATION 4" CONCRETE SLAB 2" RIGID FOUNDATION INSULATION COMPACTED ENGINEERED FILL 152 ° 2x6 TREATED SEAL PLATE ANCHOR BOLTS 1/2" x MIN. 7" EMBEDMENT x BENT AT 48" O/C i FINISH GRADE 8" GONG. FOUNDATION WALL as d I— FOUNDATION WATER I PROOFING (ASPHALT EMULSION) ° I GONG. FOOTING a L a ° I- - a �I - I1I 1 1 -II =SETA I L 2 SCALE: 3/4" = 1'- O" A1.2 SCALE: 1/4" = 1'-0" A3.1 ASPHALT SHINGLES / 1'-O" ROOF TRU55 N ROOF INSULATION 2x6 STUDS AT 16" O/G EXTERIOR WALL INSULATION PRE FINISHED METAL FLASHING W/ DRIP EDGE AND CONTINUOUS GLIP a--�AJ 2x8 TREATED } PRE FINISHED METAL V FASIGA FLASHING VENT SLOT W/ PRE FINISHED METAL LOUVER AND INSECT SCREEN (2" WIDE x 12" LONG BTWN EA. ROOF TRUSS) i WALL SHEATHING I7ETA I L EAVE SGALE: 3/4" = 1'- O" A1.2 A W 0 a - W a U W H U w ¢ W 2 W 0 z W z 0 U z W 3 0 0 3 ¢ W A 0 z 0 w Q cl z_ 3 a Q 0 w 0 D Q W N H 0 0 ¢ z z J O Z O U Q Z ¢ d 2 W z 3 0 J a 0 0 z a W U W 2 U a w r z w a- 0 IA W U W 0 W a z 0 m W ra ra z a 0 3 a ra u J J 0- cl w a U 0 0 A 3 0 u BRENT A. McFARLAND AR -2561 5-10-18 STATE OF IDAHO N N Lo M M W� C) p o = N Q � � X Q m O W N UQ� 04 N o ® 7 04 I w sA w U � o i/ > 6 w O � Z U oQ 00 N � CONSULTANTS: VI Q IL O �� NO O lu v O lu O (L IL O w O � � O c� Z ILw C) o REVISION: DRAWN BY: JOB NO: R5M 750 CHECKED BY: DATE: BAM MA'f '15 PLOT DATE: 5-09-18 DRAWING NO. FILE: 750-A1.2-FPRP * A1.2 AL2 OF (2) 2X8 HEADER (2) 2X8 HEADER 2X6 AT 24" O/G 2X6 AT 24" O/G (2) 2X8 HEADER (2) 2X8 HEADER ►-4 (2) 2X8 HEADER (2) 2X8 HEADER 2X6 AT 24" O/G 2X6 AT 24" O/G (2) 2X8 HEADER (2) 2X8 HEADER FLLOOR FRAM I N6 FL.AN 5GALE: 1/4" = I' -O" irol 0 Q 00 N N W 0 !Y W Q U W 2 U a W 0 H z W z O u z W 3 D O 2 3 Q W Q D C4 z 0 V) W A vi z_ 3 a ra W 0 W V) Q W N_ !Y 0 _ D z z J O H Z 0 u ra z a CL 2 W z 3 0 J Q O Z a W U W v a W p z a 0 U r W Q W U W O d W a z W A Q z 0 Z_ 3 a Q J J W Q U O m Q o6 3 L u BRENT A. McFARLAND AR -2561 5-10-18 STATE OF IDAHO 04 N ® o M M W00 00 O o S v o x cx cn ma) N Lu Cy)¢ r ,I 'n V ® N o I W W �" � : O > i? ¢ M cn O Z U O Q m �:: N cl:� L . CONSULTANTS: A I I Y a O lu V� lu z O O l9 O U D Z _ 3: O Q o I REVISION: DRAWN BY. JOB NO: R5M 750 CHECKED BY: DATE: BAM MAS r ' I8 PLOT DATE: 5-09-18 DRAWING NO. FILE: 750 -A1.3 -MFF * A1.3 A1.5 OF ELEV 117'-0" TOP OF WALL ELEV 106'-8" WINDOW/DOOR HEAD ELEV IOa'-O" F.F. SECOND FLOOR ELEV 106'-8" WINDOW/DOOR HEAD ELEVATION 100'-O" F.F. FIRST FLOOR ELEVATION T.O.F. 12 5.5 NOTE: E.I.F.5 TRIM TO Ed I" PROJECTED REVEAL 2 FROM SURFACE OF FIEL E.I .F.5. 12. ; 2 5 5• 3068 3068 5040 FIXED 5040 FIXE[ FRONT ELEVATION 5GALE: 1/4" = 1'-0" II-------------------------------------------------- I— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -- I EXTERIOR WALL MUST BE FIRE RATED ON BOTH SIDES WHERE UNITS ARE CLOSER THAN 10' APART 12 55 I I I I I I I FL — — — — — — — — — — — — — — — — — — — — — - — — — — — — — — — — — — — — — — — — — — — — — — — — — J -I L— — — — — — — — — — — — — — — — — — — — — — I -------- I — — — — — — — — — — — — — — — — — — — — — — J REAR ELEVATION 5GALE: 1/4" = I' -O" LEFT 511;)r= 5GALE: 1/4" = 1'-O" NOTES ( E.I.F.S. COLOR I (FIELD COLOR) O2 E.I.F.S. COLOR 2 (TRIM COLOR) O I" 'V' GROOVE (EXPANSION) O4 E.I.F.S. CAP O STONE VENEER O ASPHALT SHINGLE ROOFING ON #50 LB BUILDING FELT. ALL RIDGE LINES SHALL BE VENTED & MANUFACTURES VENTED RIDGE SHINGLE. O VINYL SIDING O8 METAL ROOF -------------------------------------------------- L- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -J RIGHT Sl=�E 5GALE: 1/4" = P -O" OL ELEV 117'-0" TOP OF WALL OL ELEV 106'-8" WINDONDOOR HEAD ELEV IOa'-O" F.F. SECOND FLOOR ELEV 106'-8" WINDOW/DOOR HEAD ELEVATION 100'-O" F.F. FIRST FLOOR ELEVATION a7' -O" T.O.F. L u BRENT A. McFARLAND AR -2561 5-10-18 STATE OF IDAHO I N N ® o M M 00 W00 O O oX n Q m � N i r , , ®No I w W �" � ZD O .w > 1 ¢ 0 EXT DOOR TO m � N � CONSULTANTS: I I Y EXT DOOR TO — — — HAVE LEVER HAVE LEVER e- ooh i0 HARDWARE HARDWARE i Pte. f�� Z O O Vlu l FRONT ELEVATION 5GALE: 1/4" = 1'-0" II-------------------------------------------------- I— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -- I EXTERIOR WALL MUST BE FIRE RATED ON BOTH SIDES WHERE UNITS ARE CLOSER THAN 10' APART 12 55 I I I I I I I FL — — — — — — — — — — — — — — — — — — — — — - — — — — — — — — — — — — — — — — — — — — — — — — — — — J -I L— — — — — — — — — — — — — — — — — — — — — — I -------- I — — — — — — — — — — — — — — — — — — — — — — J REAR ELEVATION 5GALE: 1/4" = I' -O" LEFT 511;)r= 5GALE: 1/4" = 1'-O" NOTES ( E.I.F.S. COLOR I (FIELD COLOR) O2 E.I.F.S. COLOR 2 (TRIM COLOR) O I" 'V' GROOVE (EXPANSION) O4 E.I.F.S. CAP O STONE VENEER O ASPHALT SHINGLE ROOFING ON #50 LB BUILDING FELT. ALL RIDGE LINES SHALL BE VENTED & MANUFACTURES VENTED RIDGE SHINGLE. O VINYL SIDING O8 METAL ROOF -------------------------------------------------- L- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -J RIGHT Sl=�E 5GALE: 1/4" = P -O" OL ELEV 117'-0" TOP OF WALL OL ELEV 106'-8" WINDONDOOR HEAD ELEV IOa'-O" F.F. SECOND FLOOR ELEV 106'-8" WINDOW/DOOR HEAD ELEVATION 100'-O" F.F. FIRST FLOOR ELEVATION a7' -O" T.O.F. L u BRENT A. McFARLAND AR -2561 5-10-18 STATE OF IDAHO I N N ® o M M 00 W00 O O oX n Q m � N i r , ¢ `n V ®No I w W �" � ZD O .w > 1 ¢ 0 v cn O Z U O Q m � N � CONSULTANTS: I I Y a Z O O Vlu l lu O O lu C) I REVISION: DRAWN BY. JOB NO: RSM 750 CHECKED BY: DATE: BAM MAY ' I8 PLOT DATE: 5-09-18 DRAWING N0. FILE: 750 -A2.1 -EX * A2.1 A:2.1 0F ELEV'26-9 3/411" RID6P ELEV II -I' -O" TOP OF WALL ELEV 115'-8" HINDOW/DOOR HEAD ELEV loci' -O" F.F. SECOND FLOOR 01 ELEV 106'-8" HINDOW/DOOR HEAD AS PER IBC 1207.3 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS SHALL HAVE A IMPACT INSULATION CLASS (11C) RATING OF NOT LESS THAN 50 (KEYNOTES OI COMPACTED ENG 1 NEERED FILL O UNDER SLAB VAPOR BARRIER O 4" FREE DRAINING GRAVEL O 2" RIGID FOUNDATION INSULATION OS FOUNDATION WATER PROOFING O6 EXTERIOR AIR INFILTRATION BARRIER ON EXTERIOR WALL SHEATHING CONTINUOUS TYP I CAL O 1 HOUR FIRE RATED SOUND WALL O I HOUR FIRE RATED FLOOR/CE I L I NG ASSEMBLE O EXTERIOR WALL BATT INSULATION 10 ROOF BATT INSULATION II SOUND INSULATION 12 VENT SLOT W/ PRE FIN 1 SHED METAL LOUVER AND INSECT SCREEN (12" LONG BTWN EA. ROOF TRUSS) 13 ASPHALT SHINGLE ROOFING ON #30 LB BUILDING FELT. ALL RIDGE LINES SHALL BE VENTED W/ MANUFACTURES VENTED RIDGE SHINGLE. 14 4" GONG. SLAB ON GRADE i=LEVATION 100'-0" U U 15 PRE CAST CONCRETE STAIR TREADS F.F. FIRST FLOOR ,.... 1-LEVATION ci'7'-O" T.O.F. ELEV 126-q 3/4"" /-6, RIDGE ELEV 117'-0" TOP OF WALL ELEV 115'-8" WINDOKVOOR HEAD ELEV loci' -O" F.F. SECOND FLOOR ELEV 106-8" HINDOW/DOOR HEAD ELEVATION loo'- F.F. FIRST FLOOR ELEVATION q7' -G T.O.F. BU I L =O I NCG SECTION SCALE: 1/4" = P -O" 5U I L.I;) I N& SECTION 5GALE: 1/4" = P -O" G ASSEMBLY MUST BE 1 HR. RATED �.ORATI VE )55 OL ELEV 112'-8" BTfM. OF BEAM SQUARE TUBING AT 4" ; WELDED TO 1 1/2" UND TOP AND BOTTOM IL. ALL WELDS TO BE OUND SMOOTH NOTE: HANDRAIL AND GUARDRAIL SHALL BE ON EAGH 51DE OF STAIR AS PER IBC 1207.3 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS SHALL HAVE A IMPACT INSULATION CLASS (11C) RATING OF NOT LESS THAN 50 MINIMUM IN5UL4TI0N 'R' VALUE5 EXTERIOR HALL R21 ROOF Rag FOUNDATION HALL R20 SOUND INSL. FLOORS RII Q w 0 w a U w U a w L, Z w Z 0 U Z w 3 O 2 3 ¢ w Q 0 z 0 V) w A (1 z_ 3 a Q D w V) w N_ 0 _ D z r Z ¢ J 0 z 0 u ra z a CL w z 3 0 J ¢ 0 z a w U w U a w p z ¢ r U r AQ Q w U w 0 w a z w A Q Z 0 z 3 a Q J J w U 0 o6 3 L u BRENT A. McFARLAND AR -2561 5-10-18 STATE OF IDAHO 04 N ® o M M Wco co 00 Q o x Q� m LuN 0� Q"- ® co �w J w U ^I /\ O > Q 0 0 0 7:(-) U O Q m� N � Lr)� CONSULTANTS: A I I Y Q Z O O Vl l lu O O 'I� u l9 C) � o REVISION: DRAWN BY. JOB NO: RSM 750 CHECKED BY: DATE: BAM MAY 'I S PLOT DATE: 5-09-18 DRAWING NO. FILE: 750 -A3.1 -BS * A3.1 A5.1 5 OF