Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPLICATION - 18-00247 - 165 S Hidden Valley Rd - Addition
CITY O F REXBURG CW America's Family Community Building Safety Department City of Rexburg 35 North 1St East Idaho 83440 SINGLE FAMILY RESIDENTIAL ADDITION APPLICATION CHECKLIST The following items should be completed before you submit your building permit application. *Reasonable accommodations will be made upon request. Submit the Following Documents: 19� 2 sets of site plans drawn to scale fi� 2 sets of building plans drawn to scale (see box to right) ❑ Foundation Plan, Floor Joist Layout, Floor Plan, Roof Layout, Truss Details, Sectional Views, Front, Back, and Side Elevations, Mechanical Layout Stair Details, and any details required to illustrate special construction. 15 --Structural Calculations (see box to right) - stamped by a licensed Engineer - D Energy Compliance Report: As per the 2015 IECC, a RESCheck is Ground Snow - 501bSeismic Design Categorys. per sq. ft. required (available online at www.energycodes.gov) Roof Snow Load - 35 lbs. per sq. ft. 14 Digital Plans (PDF Format- can be submitted by USB, CD, or Dropbox) Wind Load - 90 MPH ❑ **Copies of any Contractors' State License if not on file already. Frost Depth - 36" Complete the Following Forms: Is Permit Policies Acknowledgment signed. k Property Line form signed by builder. J�- Building Permit Application signed by a registered General Contractor. @4:. Mechanical Permit Application signed by a registered Mechanical Contractor. 1�8-- Electrical Permit Application signed by a registered Electrical Contractor. &K Plumbing Permit Application signed by a registered Plumbing Contractor. Subcontractor list completed. 0"omeowner's Exemption signed, if Homeowner is doing work on their own home. W^ Affidavit of Legal Interest signed by owner, if applicant is not working directly with owner. ❑ Notifications Distribution List. Subdivisions: If you plan to build in a subdivision please check the Rexburg Development Code for any requirements such as property setbacks, architecture board approval, etc. This information is available at http://rexburg.org/pages/development-code. Inspection Hotline - (208) 372.2344 www.rexburg.org Permit Technician - (208) 372.2341 Revised 10/2016 C I TY OF REXBURG America's Family Community SITE PLAN CHECKLIST Building Safety Department City of Rexburg 35 North 1St East Rexburg, Idaho 83440 ❑ 1 Site plan must be drawn to scale, be legible and also be submitted electronically if possible. ❑ 2. Adjoining streets labeled. fJ/,k l5L 3. Right-of-way location and width, curb to curb widths and sidewalk location. ❑ 4. Building location, sq footage and dimensions, with distance to property lines and distances between buildings. ❑ 5. Show existing and proposed easements. ❑ 6. Existing utilities (waterlines, sanitary sewer lines, manholes, storm drains). N/A X 7. Proposed utilities including tie in location to existing services and new easements. t4/A, JR 8. Proposed storm drain and sanitary sewer elevations (for pipe inverts at manholes and catch basins). �/A 19 9. Storm drainage plan for parking lot and roof areas, with calculations. i4 /1. 9 10. Fire hydrants and fire suppression lines (including tie to City lines). / ❑ Sprinkled R.Not Sprinkled ❑ 11. Indicate Fire apparatus access. 9 12. Parking (including parking lot, drainage arrows, dimension of lot, distance between rows, and total numbers). (�1 IR 13. Landscaping (type and total area, including dimensions). AJ t g4A-WUCs t4/ - W 14. Trash facilities. 1I0 CffANC-C!5 F V 15. North Arrow Included UK 16. Proposed street improvements (curb, gutter, sidewalk, pavement, etc.) N/A 14 17. Legal description of proposed building site included. ❑ 18. Percent of lot covered by building or paving calculated. ❑ 19. Show 10% snow storage area. ❑ 20. Distance of entrances from street corner indicated. ❑ 21. Current Vicinity Map. (8 1/2 x 11") at 1" = 300' scale, showing location of the property. ❑ 22. Lighting Plan SITE PLANS MUST BE COMPLETE AND SUBMITTED FOR REVIEW BEFORE THE PROJECT WILL BE PLACED ON THE PLANNING & ZONING AGENDA. Inspection Hotline - (208) 372.2344 www.rexburg.org Permit Technician -(208) ) 372.2341 Revised 10/2016 04 gEXB URG .a CITY OF Building Safety Department V 0 nrVnTm 1�1�y1tG BUILDING PERMIT FORM 102 City of Rexburg QW Updat d10/2016 35 North 1St East America's Family Community Rexburg, Idaho 83440 For Office Use Permit Number: BUILDING APPLICATION Single Family Residence Addition Zoning: Application Fee Paid: ❑ $100 1. Prope ty Owner Name: 5 UAl�jvjy Address: nr ry City: State: Zip Code: Phone: ' D 'a C2 Z� 1�' `�� Email: 1 Under Idaho Building Code, a homeowner is allowed to do work on th own ho e. Are you a homeowner doing work on your own home? P<Yes (Skip to #4 and complete the Homeowner's Exemption) ❑ No, I am a contractor working for the homeowner 2. Appli ant tt / Name: �� ill 1 Role: (Owner, Tenant, Contractor, etc.) �dC li'/OW146s Address: ? j 3 � ,� r r City: �t� i� Zip C�e3���OPhone: �e4, 34_' • 15Cj�P lk 2t "It i 49qEmail:li �3 @ Contact/Rep. Name: 3. General Contractor Name: 6 ei,�7- Addres Phone: Contact/Rep. Name: General Contractor Authorized Signature: A copy ofyour state registration/license is req 'red to a photo copy ofyour license. Ifyou are unsure jf your I. 4. Project De cripti n Address, ` (i • 1-6 A Ae, 0 Project Description: • Square Feet of Addition: q R • Estimated Total Cost: $ / 00 Op©. 4 • Fireplace(s) Being Installed? ❑ YesA No Registration #: City: State Exp.: _ Zip Code: Phon : Email: Date: on file. If th s th irst me you have done work in the City of Rexb rg,Wpleaseit Ise is on file, ease hec with the Permit Technician by calling (208) 372-2341. Building Permitfees for new homes are charged based on square footage and the City's estimated valuation. For details on howfees are calculated, contact the Building Department. There will also be a plan review fee totaling 10% of the building permit fee. APPLICANT'S SIGNATURE, CERTIFICATION AND AUTHORIZATION: Under penalty of perjury, I hereby certify that 1 have read this application and state that the information herein is correct and I swear that any information which may hereafter be given by me in hearings before the Planning and Zoning Commission or the City Council for the City of Rexburg shall be truthful and correct. I agree to comply with all City regulations and State laws relating to the subject matter of this application and hereby authorized representatives of the City to enter upon the above-mentioned property for inspections purposes. NOTE: The building official may revoke a permit on approval issued under the provisions of the 2012 International Code in cases of any false statement or misrepresentation of fact in the application or on the plans on which the it or approval was based. Permit void if not started within 180 days. Permit void if work stops for 180 days. 1 Applicant's Name (print} �'�Ae �j1Y'1 Signature; ` e: Inspections must be called in beforeM on the day t le inspection is requested. Inspection requests called in after A will b scheduled for the next business day. Inspection Hotline - (208) 372.2344 www.rexburg.org Permit Technician - (208) 372.2341 APPLICANT'S SIGNATURE, CERTIFICATION AND AUTHORIZATION: Under penalty of perjury, I hereby certify that I have read this application and state that the information herein is correct and I swear that any information which may hereafter be given by me in hearings before the Planning and Zoning Commission or the City Council for the City of Rexburg shall be truthful and correct. 1 agree to comply with all City regulations and State laws relating to the subject matter of this application and hereby authorized representatives of the City to enter upon the above-mentioned property for inspections purposes. NOTE: The building official may revoke a permit on approval issued under the provisions of the 2012 International Code in cases of any false statement or misrepresentation of fact in the application or on the plans on which the permit or approval was based. Permit void if not started within 180 days. Permit void if work stops for 180 days. Applicant's Name (print): Signature: Date: Inspections must be called in before 8 AM on the day the inspection is requested. Inspection requests called in after 8 AM will be schedul Inspection Hotline - (208) 372.2344 ed for the next business day. www.rexburg.org Permit Technician - (208) 372.2341 O� gEXBUigC U� fax C I T Y o f Building Safety Department REX-BURG BUILDING PERMIT 13 2 City of Rexburg �'►<, dFORM ,ted 10/2016 America' Family Community 35 North 15;1 East Rexburg, Idaho 83440 BUILDING APPLICATION New SFR Plumbing For Office Use Permit Number: ❑ Plumbing Fee Paid 1. Property Owner Name: r' �2 jpSZfy r, Address:�t City: L � State: I) '%D Zip Code: T O Phone:r (� CQ 1 �% Email•Gd Under Idaho Building Code, a homeowner is allowed to do work on their own home. Are you a homeowner doing work on your own home? ❑ Yes (Skip to #3 and complete the Homeowner's Exemption) P`No, I am working with the homeowner 2. Plumbing Contractor Business:��I�T. �,� (1� State License #: Address: Exp.: City: State: Phone: Zip Code: Email: Contact/Rep. Name: Phone: Email: Plumbing Contractor Authorized Signature: A l [6_ J� Date: _ ! cop o py fyour state registration/license is required to be on file. If this is the first time you have done work in the City of Rexburg, please provide a photo copy ofyour license. Ifyou are unsure ifyour license is on file, please check with the Permit Technician by calling (208) 372-2341. 3. Project Descri ti n Ld P Address: • r -OR- Lot #: _ Block #: _ Subdivision: Description of work: ❑ New SFR Construction: i Wei sq. ft, • Fees for additions are charged by square footage: Up to 1,500 sq. ft. = $130 + $65 for each additional 1,000 sq. ft. or portion thereof. 0 Up to 1,500 sq. ft. = $130. Up to 2,500 sq, ft. = $195. Up to 3,500 sq. ft. = $260. Up to 4,500 home with 3,675 sq. ft. will be charged $325) sq. ft. = $325, etc. (i.e. a ❑ Hydronic (In -floor) Heating:X Yes ❑ No • Note that hydronic heating is not included in square footage costs and will be charged $65 extra. APPLICANT'S SIGNATURE, CERTIFICATION AND AUTHORIZATION: Under penalty of perjury, I hereby certify that I have read this application and state that the information herein is correct and I swear that any information which may hereafter be given by me in hearings before the Planning and Zoning Commission or the City Council for the City of Rexburg shall be truthful and correct. 1 agree to comply with all City regulations and State laws relating to the subject matter of this application and hereby authorized representatives of the City to enter upon the above-mentioned property for inspections purposes. NOTE: The building official may revoke a permit on approval issued under the provisions of the 2012 International Code in cases of any false statement or misrepresentation of fact in the application or on the plans on which the permit or approval was based. Permit void if not started within 180 days. Permit void if work stops for 180 days. Applicant's Name (print): Signature: Date: Inspections must be called in before 8 AM on the day the inspection is requested. Inspection requests called in after 8 AM will be schedul Inspection Hotline - (208) 372.2344 ed for the next business day. www.rexburg.org Permit Technician - (208) 372.2341 as��xaugc CITY T0 F Building Safety Department T�FX1jJjl BUILDING PERMIT FORM 112 City of Rexburg CW unazceaio,zoie 35 North 1St East America's FamUy Community Rexburg, Idaho 83440 BUILDING APPLICATION Addition SFR Mechanical For Office Use Permit Number: ❑ Mechanical Fee Paid 1. Property Owner Name: "e Address: ein � 3[j✓4 City; fit° ' State: Zip Code: ✓ r� Phone: 109 30 �,'7 ��%C.PU 20 S i! � U 9 . y am_ —rel. YV04 Ct � Email: Vp,�Ult'S 1'7�i} f� S 3 (C� r� Under Idaho Building Code, a homeowner is allowed to do work on tVeir own &mj ` Are you a homeowner doing work on your own home? ❑ Yes (Skip to #3 and complete the Homeowner's Exemption) GPde, I am working with the homeowner 2. Mechanical Contractor++ �� Business: ��'i�{t H, State License #: �' Address: Exp.: City: State: Zip Code: Phone: Email: Contact/Rep. Name: Phone: Email: Mechanical Contractor Authorized Signature:—'� Date:/ A copy ofyour state registration/license is required to be on file. if this is the first time you have done work in the City of Rexburg, please provide a photo copy ofyour license. Ifyou are unsure ifyour license is on file, please check with the Permit Technician by calling (208) 372-2341. 3. Project Descripti-- Address: Z��j. jL�( L� �A" Description of work: ❑ New SFR Construct'01 ti sq R • Fees for additions are charged by square footage: Up to 1,500 sq. ft. = $130 + $65 for each additional 1,000 sq. ft. or portion thereof. o Up to 1,500 sq. ft. = $130. Up to 2,500 sq. ft. = $195. Up to 3,500 sq. ft. = $260. Up to 4,500 sq. ft. = $325, etc. (i.e. a home with 3,675 sq. ft. will be charged $325) ❑ Number of Fireplaces: 0 • Note that fireplaces are not included in square footage costs and will be charged $65 per inspection. APPLICANT'S SIGNATURE, CERTIFICATION AND AUTHORIZATION: Under penalty of perjury, I hereby certify that I have read this application and state that the information herein is correct and I swear that any information which may hereafter be given by me in hearings before the Planning and Zoning Commission or the City Council for the City of Rexburg shall be truthful and correct. 1 agree to comply with all City regulations and State laws relating to the subject matter of this application and hereby authorized representatives of the City to enter upon the above-mentioned property for inspections purposes. NOTE: The building official may revoke a permit on approval issued under the provisions of the 2012 International Code in cases of any false statement or misrepresentation of fact in the application or on the plans on which the permit or approval was based. Permit void if not started within 180 days. Permit void if work stops for 180 days. Applicant's Name (print): Signature: Date: Inspections must be called in before 8 AM on the day the inspection is requested. Inspection requests called in after 8 AM will be scheduled for the next business day. Inspection Hotline - (208) 372.2344 www.rexburg.org Permit Technician - (208) 372.2341 F RkXB U,pC U° r� C I T Y o f Building Safety Department BUILDING PERMIT FORM 1Z 2 City of Rexburg 1Ey1tG nPd ted 1o,Zotb 35 North 1St East '•<,, America's Family Community Rexburg, Idaho 83440 BUILDING APPLICATION Addition SFR Electrical For Office Use Permit Number: ❑ Electrical Fee Paid 1. Prop rty Owner Name: _ Address: l 5 e s CState: Zip CodePl� Phone:' ��� ° —1,5,()Ge Zo rg ' l �� Email: Under Idaho Building Code, a homeowner is allowed to do work on their own home. _ v Are you a homeowner doing work on your own home? ❑ Yes (Skip to #3 and complete the Homeowner's Exemption) PNo, I am working with the homeowner 2. Electrical Contractor Business:. i _Y`�y,(1 State License #: Exp.: Address: City: State: Zip Code: Phone: Email: Contact/Rep. Name: Phone: Email: Electrical Contractor Authorized Signatures---�_ 1"C- Dater_ A copy ofyour state registration/license is required to be on file. If this is the first time you have done work in the City of Rexburg, please provide a photo copy ofyour license. Ifyou are unsure ifyour license is on file, please check with the Permit Technician by calling (208) 372-2341. 3. Project Description, Address: l�.Sy G Aey, _OR_ Lot #: _ Block #: _ Subdivision: Description of work: V,New SFR Construction: sq, • Fees for additions are charged by square footage: Up to 1,500 sq. ft. = $130 + $65 for each additional 1,000 sq. ft. or portion thereof. o Up to 1,500 sq. ft. = $130. Up to 2,500 sq. ft. = $195. Up to 3,500 sq. ft. = $260. Up to 4,500 sq. ft. = $325, etc. (i.e. a home with 3,675 sq. ft, will be charged $325) ❑ Spas/Pools/Generators: ❑ Yes ❑ No • Note that spas/pools/generators are not included in square footage costs and will be charged $65 per inspection. APPLICANT'S SIGNATURE, CERTIFICATION AND AUTHORIZATION: Under penalty of perjury, I hereby certify that I have read this application and state that the information herein is correct and I swear that any information which may hereafter he given by mein hearings before the Planning and Zoning Commission or the City Council for the City of Rexburg shall be truthful and correct. I agree to comply with all City regulations and State laws relating to the subject matter of this application and hereby authorized representatives of the City to enter upon the above-mentioned property for inspections purposes. NOTE: The building official may revoke a permit on approval issued under the provisions of the 2012 International Code in cases of any false statement or misrepresentation of fact in the application or on the plans on which the permit or approval was based. Permit void if not started within 180 days. Permit void if work stops for 180 days. Applicant's Name (print): Signature: Date: Inspections must be called in before 8 AM on the day the inspection is requested. Inspection requests called in after 8 AM will be scheduled for the next business day. Inspection Hotline - (208) 372.2344 www.rexburg.org g g Permit Technician - (208) 372.2341 CITY OF REXBURG Americas Family Community PERMIT POLICIES ACKNOWLEDGMENT Building Safety Department City of Rexburg 35 North 1St East RPxhltry irlalhn PgAAfl The City of Rexburg Building Safety Department is determined to provide excellent customer service. In an effort to help you understand the City of Rexburg Permit Policies, listed below are several policies which you are required to know prior to proceeding with your project. Any construction within the City of Rexburg which requires a permit shall not begin until an approved permit is obtained. If you do not have a Pink Building Permit signed by the Building Inspector, then you do not have an approved permit. o Building without the pink building permit signed by the Building Inspector will result in double fees to be assessed and the project to be red tagged. If your project is red tagged, halting all construction, only a City Official may remove the red tag. If the red tag is removed by anyone but a City Official, citations may be issued. No building may be occupied without receiving a signed Certificate of Occupancy. o If a building is occupied without receiving a signed Certificate of Occupancy, citations may be issued and the occupants may be evicted. Init' l Scheduling inspections is the responsibility of the applicant and their contractor. Inspections need to be called into the hotline and not to the inspector. Inspections called in later than 8 AM will be scheduled for the following business day. o If an inspection is not done, the inspector may require any measures to be taken to allow him to correctly perform the inspection. (Example: If the electrical rough in inspection is not done and the sheetrock has been Inl 'Is put up, the inspector may require the sheetrock to be removed in order to perform the electrical rough in inspection.) Construction on any project can begin ONLY when you have received a Pink Building Permit from the Building Department. Occupancy of any structure can begin ONLY when you have received an official Certificate of Occupancy from the Building Department. These documents must be signed by the appropriate authorities from the City of Rexburg. Any approvals can be verified by calling (208) 372-2341. o Even if you hear from an inspector that'you're good to go', ultimately if you do not have a Building Permit or Certificate of Occupancy, the above policies will be enforced. Init I It is your responsibility to inform anyone on your project of the above policies. All sub -contractors will be held to this standard with no exceptions. c The above policies will be enforced to all, regardless if this information"is`passed on to them or not. Initi Applicant's Name (print). eS�\ Signature: Date: Inspections must be called in before 8 AM on the day the inspection is requested. Inspection requ s called in after w 11 be scheduled for the next business day. Inspection Hotline - (208) 372.2344 www.rexburg.org Pe Technician -208 372.2341 ( ) Revised 10/2016 o�aExsuR� C I TY OF REXBURG Americas Family Community PROPERTY LINES Building Safety Department City of Rexburg 35 North 1St East Rexburg. Idaho, RU4n Each site plan that is submitted to the City of Rexburg for the Building Permit process requires that property lines are shown accurately. It is the Developer's responsibility to correctly identify on the site plan the location of these lines in reference to the public right-of-way, other adjoining property lines, the street, other structures and all utility lines. The Developer should find property pins that are still available at the lot in question. If these pins do not exist or have become unrecognizable then a new survey should be performed. Accurate property line information is a must for a timely review. In addition to finding existing property pins, legal descriptions should be checked. The best way to identify property line location is with a land survey. The City of Rexburg has aerial photos and a parcel line layer that can be checked, but they are only a tool and are not guaranteed for accuracy. If you want to request a copy of your lot, see the front counter at the Community Development Department. I have read and understand the above requirements. oil &b n re Date Re Printed Name Inspection Hotline - (208) 372.2344 www.rexburg.org Permit Technician - (208) 372.2341 Revised 10/2016 04 �axsvR� C] TY o f Building Safety Department REXBURG City of Rexburg 0&1 35 North 1St East America's Family y Community neo Rexburg, Idaho 83440 HOMEOWNER'S EXEMPTION As of January 1, 2006, the City of Rexburg can no longer sell permits without having a copy of your State registration number or your exemption from the State registration. Please fill out this form showing your exemption and send it with your permit application. Idaho State Statute allows a homeowner to do work on their own residence: An owner performing construction on the owner's personal residential real property, whether or not occupied by the owner, provided however, this exemption shall not apply to an owner who is otherwise regulated by this chapter who constructs a building, residence or other improvement on the owner's property with the intention and for the purpose of promptly selling the improved property, unless the owner has continuously occupied the property as the owner's primary residence for not less than twelve (12) months prior to the sale of such property; Title 54, Chapter 52, Subsection (2) I hereby certify hat the bove information is true and correct to the best of my knowledge. 1 fiature Date �1 Print Name Permit Technician - (208) 372.2341 www.rexburg.org Revised 10/2016 OF gEXB U`QC &� f� CITY OF Building Safety Department N R.EXBURG City of Rexburg "" 35 North 15t East America's Family Community Rexburg, Idaho 83440 Excavation & Earthwork: U�1 �- I Concrete: Z. Masonry: _ Roofing: _ Insulation: Drywall: Painting: Floor Coverings: Plumbing: Heating: Electrical: 1 1 b Roof Trusses: SUBCONTRACTOR LIST Special Construction (Manufacturer or Supplier) Floor/Ceiling Joists: Siding/Exterior Trim: Other: Inspection Hotline - (208) 372.2344 www.rexburg.org Permit Technician -208 3 ( )72.2341 Revised 10/2016 r4Generated by REScheck-Web Software Compliance Certificate Project Addition Energy Code: 2009 IECC Location: Rexburg, Idaho Construction Type: Single-family Project Type: Addition Climate Zone: 6 (8693 HDD) Permit Date: 38 Permit Number: 616 Construction Site: Owner/Agent: Designer/Contractor: 165 S. Hidden Valley Rd James Papworth Rexburg, ID 83440 165 S. Hidden Valley Rd Rexburg, ID 83440 2087154984 jamespapworth53@gmail.com Compliance: Passes using UA trade-off Compliance: 35.8% Better Than Code Maximum UA: 106 Your UA: 68 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies a• • — _--v .. i i uw5 616 16.0 32.0 0.020 12 Wall: Wood Frame, 16" o.c. 1,232 16.0 16.0 0.031 38 Floor: All -Wood joist/Truss 616 16.0 16.0 0.029 18 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name -Title Signature Date Project Title: Addition Report date: 04/09/18 Data filename: Pagel of 7 CREScheck Software Version : REScheck-Web �(J Inspection Checklist Energy Code: 2009 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # & Re .lD Pre-Inspection/Plan Review PIanV luefied FielValue�ed Complies? Comments/Assumptions 103.2 Construction drawings and ❑Complies Requirement will be met. [PRI]l documentation demonstrate ❑Does Not d, energy code compliance for the building envelope. ❑Not Observable ❑Not Applicable 103.2, 403.7 Construction drawings and documentation demonstrate ❑Complies []Does Not Requirement will be met. [PR3]1 energy code compliance for lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the commercial code. 403.6 [PR2]2 Heating and cooling equipment is sized per ACCA Manual S based Heating: Heating: Btu/hr Btu/hr ❑Complies ❑Does Not Requirement will be met. on loads per ACCA Manual J or other approved methods. Cooling: Coolin g ❑Not Observable Btu/hr Btu/hr ❑Not Applicable ...—...... �v..unCnUS/AssumpLions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact {Tier 3) Project Title: Addition Data filename: Report date: 04/09/18 Page 2 of 7 B M C WEST CORP - REXBURG 202 W MAINT STREET REXBURG, ID 83440-0188 Quote Name: Jim Papworth Quote Number: SQPDJD000660_1 Customer: B M C WEST CORP - REXBURG Created Date: 4/25/2018 Payment Terms: Modified Date: 4/25/2018 Sales Representative: Dallen Wilding Mobile: PO Number: dallen.wilding@buildwithbmc.com Total Units: 19 Total Sq Ft: 327.00 Comments: Est. Delivery: Billing Information Shipping Information Name: B M C WEST CORP - REXBURG Name: Address: 202 W MAINT STREET Address: REXBURG, ID 83440-0188 Phone: Fax: Email: Phone: Fax: Email: Line: 1 Location: Quantity: 2 Montecito, 8360M, SP, 13/8" Setback, Ext White /Int White U-Factor:.28, SHGC:.29, VT: .55 Gray EdgeGardMAX Spacer Energy Star North-Central Flat Ext White/Int White, Custom Argon Gas Filled Viewed From Exterior Size: Net Frame 35 1/2" x 711/2" Net Frame 35 1/2" X Item Total: 711/2" Item Qty Total: Model: Special - Composite Design Energy Package: Energy Star North-Central Glass: 3/32" SunCoat (Low -E) over 3/32" Clear Other Glass: Gray EdgeGardMAX Spacer with Argon Grid: 1.1-PWR Fixed None 2.1-PWR Fixed Flat Ext White/Int White Colonial 3W1H Ratings: STC: No Rating, OITC: No Rating, No Ratings Other Ratings: CPD: MIL -A-236-04458-00001 Customer Approval: $255.70 $20.93 ($7.53) $6.28 $10.88 $286.25 $572.51 Quote Number: SQPDJD000660_1 Print Date: 4/25/2018 Page 1 of 6 Line: 2 Location: Quantity: 2 Montecito, 8360M, SP, 13/8" Setback, Ext White /Int White U-Factor:.27, SHGC:.29, VT: .55 1/8" SunCoat (Low -E) Tempered over 1/8" Clear Tempered Gray EdgeGardMAX Spacer Energy Star North-Central Flat Ext White/Int White, Custom Argon Gas Filled Size: Net Frame 35 1/2" x 711/2" Net Frame 35 1/2" X 711/2" Model: Special - Composite Design Energy Package: Energy Star North-Central Glass: 1/8" SunCoat (Low -E) Tempered over 1/8" Clear Tempered Other Glass: Gray EdgeGardMAX Spacer with Argon Grid: 1.1-PWR Fixed None 2.1-PWR Fixed Flat Ext White/Int White Colonial 3W1H Ratings: STC: No Rating, OITC: No Rating, No Ratings Other Ratings: CPD: MIL -A-236-04461-00001 $255.70 $110.90 $20.93 ($7.53) $6.28 $10.88 Item Total: $397.16 Item Qty Total: $794.31 Viewed From Exterior Customer Approval: Line: 3 Location: Quantity: 6 Montecito, 8520M, SP, 13/8" Setback, Ext White /Int White U-Factor:.27, SHGC:.25, VT: .47 1/8" SunCoat (Low -E) over 1/8" Clear Gray EdgeGardMAX Spacer Energy Star North-Central Flat Ext White/Int White, Custom Argon Gas Filled Viewed From Exterior Size: Net Frame 35 1/2" x 711/2" Net Frame 35 1/2" X Item Total: 711/2" Item Qty Total: Model: Special - Composite Design Handing: Casement Left Energy Package: Energy Star North-Central Glass: 1/8" SunCoat (Low -E) over 1/8" Clear Other Glass: Gray EdgeGardMAX Spacer with Argon Grid: 1.1 -FC Vent None 2.1 -CAF Fixed Flat Ext White/Int White Colonial 3W1H Hardware: Standard Roto/Stainless Steel Operator Handle, Wash Hinge Screen: Standard with Fiberglass Mesh Ratings: STC: 31, OITC: 24, No Ratings Other Ratings: CPD: MIL -A-227-05639-00001 Customer Approval: $474.58 $6.70 $20.93 ($7.53) $7.11 $10.88 $512.66 $3,075.98 Quote Number: SQPDJD000660_1 Print Date: 4/25/2018 Page 2 of 6 Line: 4 Location: Quantity: 1 Montecito, 8360M, SP, 13/8" Setback, Ext White /Int White U-Factor:.27, SHGC:.29, VT: .54 1/8" SunCoat (Low -E) over 3/16" Clear Energy Star North-Central Gray EdgeGardMAX Spacer Flat Ext White/Int White, Custom Argon Gas Filled Size: Net Frame 711/2" x 711/2" Net Frame 711/2" X Item Total: 711/2" Item Qty Total: Model: Special - Composite Design Energy Package: Energy Star North-Central Glass: 1/8" SunCoat (Low -E) over 3/16" Clear Other Glass: Gray EdgeGardMAX Spacer with Argon Grid: 1.1-PWR Fixed None 2.1-PWR Fixed Flat Ext White/Int White Colonial 6W1H Ratings: STC: No Rating, OITC: No Rating, No Ratings Other Ratings: CPD: MIL -A-236-04962-00001 Viewed From Exterior Line: 5 Location: Quantity: 2 Montecito, 8320M, PW, 13/8" Setback, Ext White /Int White U-Factor:.28, SHGC:.26, VT: .49 1/8" SunCoat (Low -E) over 1/8" Clear Gray EdgeGardMAX Spacer Flat, Ext White/Int White, 12" Valance 3W1H Energy Star North-Central Argon Gas Filled Viewed From Exterior Size: RO 36" x 48" Net Frame 35 1/2" X 47 1/2" Model: Picture Energy Package: Energy Star North-Central Glass: 1/8" SunCoat (Low -E) over 1/8" Clear Other Glass: Gray EdgeGardMAX Spacer with Argon Grid: Flat, Ext White/Int White, 12" Valance 3W1H Ratings: STC: 31, OITC: 25, Tested: CW40 Other Ratings: CPD: MIL -A-229-08057-00002 Customer Approval: Item Total: Item Qty Total: Customer Approval: $428.54 $7.53 ($15.07) $7.11 $12.14 $21.34 $461.61 $461.61 $147.31 $4.60 $14.23 $24.69 ($5.02) $7.11 $192.93 $385.86 Quote Number: SQPDJD000660_1 Print Date: 4/25/2018 Page 3 of 6 Line: 6 Location: Quantity: 1 Montecito, 8520M, FC, 13/8" Setback, Ext White /Int White U-Factor:.27, SHGC:.25, VT: .47 1/8" SunCoat (Low -E) over 1/8" Clear Gray EdgeGardMAX Spacer Energy Star North-Central Fold Down Roto/Stainless Steel Operator Handle Argon Gas Filled Size: RO 36" x 48" Net Frame 35 1/2" X 47 1/2" Model: Casement Handing: Casement Left Energy Package: Energy Star North-Central Glass: 1/8" SunCoat (Low -E) over 1/8" Clear Other Glass: Gray EdgeGardMAX Spacer with Argon Hardware: Fold Down Roto/Stainless Steel Operator Handle, Wash Hinge Screen: Standard with Fiberglass Mesh Ratings: STC: 31, OITC: 24, Tested: LC60 Clear Opening: W 23 13/16" x H 42 15/16" Sq. Ft. 7.1 Egress: Yes Other Ratings: CPD: MIL -A-227-05639-00001 $285.00 $4.60 $14.23 ($5.02) $8.79 $7.11 Item Total: $314.71 Item Qty Total: $314.71 I Viewed From Exterior Customer Approval: Line: i Location: Quantity: 2 Montecito, 8320M, PW, 13/8" Setback, Ext White /Int White U-Factor:.28, SHGC:.29, VT: .55 1/8" SunCoat (Low -E) Tempered over 1/8" Clear Tempered Gray EdgeGardMAX Spacer Energy Star North-Central Argon Gas Filled T Viewed From Exterior Size: RO 36" x 60" Net Frame 35 1/2" X 59 1/2" Item Total: Model: Picture Item Qty Total: Energy Package: Energy Star North-Central Glass: 1/8" SunCoat (Low -E) Tempered over 1/8" Clear Tempered Other Glass: Gray EdgeGardMAX Spacer with Argon Ratings: STC: 31, OITC: 25, Tested: CW40 Other Ratings: CPD: MIL -A-229-08057-00001 Customer Approval: $179.12 $95.00 $17.58 ($6.28) $8.79 $294.21 $588.41 Quote Number: SQPDJD000660_1 Print Date: 4/25/2018 Page 4 of 6 Line: 8 Location: Quantity: 3 Montecito, 8520M, FC, 13/8" Setback, Ext White /Int White U-Factor:.27, SHGC:.25, VT: .47 1/8" SunCoat (Low -E) over 1/8" Clear Gray EdgeGardMAX Spacer Energy Star North-Central Fold Down Roto/Stainless Steel Operator Handle Argon Gas Filled Viewed From Exterior Size: RO 36" x 60" Net Frame 35 1/2" X 59 1/2" Model: Casement Handing: Casement Left Energy Package: Energy Star North-Central Glass: 1/8" SunCoat (Low -E) over 1/8" Clear Other Glass: Gray EdgeGardMAX Spacer with Argon Hardware: Fold Down Roto/Stainless Steel Operator Handle, Wash Hinge Screen: Standard with Fiberglass Mesh Ratings: STC: 31, OITC: 24, Tested: LC60 Clear Opening: W 23 13/16" x H 5415/16" Sq. Ft. 9.08 Egress: Yes Other Ratings: CPD: MIL -A-227-05639-00001 Item Total: Item Qty Total: Customer Approval: $319.32 $ 5.44 $17.58 ($6.28) $8.79 $8.79 $353.63 $1,060.90 Quote Number: SQPDJD000660_1 Print Date: 4/25/2018 Page 5 of 6 err B M C WEST CORP - REXBURG 202 W MAINT STREET REXBURG, ID 83440-0188 14e, Z691.1- Material Subtotal: $7,254.28 Submitted By: Grand TotalUSD ( ) $7,254.28 Accepted By: Date: ----------------------------------------------------------------------- For warranty information please visit www.milgard.com/warranty/ Please note that actual NFRC energy values may vary from those reported in CTB Quote Plus due to variations that may occur during the manufacturing process. In most cases variations will be minimal. Please contact your Milgard location with questions or concerns regarding this potential variation. Handing is viewed from outside looking in. ADDITIONAL INFORMATION: Quote Number: SQPDJD000660_1 Print Date: 4/25/2018 Page 6 of 6 Project: JIM PAPWORTH Model: Contact: Site: Name: Phone: Fax: Tentative Delivery Date: Profile: To: BOH (IF) Block No: Lot No: Job Number: 18-055892T Page: 1 Date: 05/04/18 10:35:52 Miscellaneous Items Quantity: Description: 6 LUS24IDF THIS OiTOTATION IS ONLY GOOD FOR 30 DAYS FROM DATE PRINTED TRUSS ESTIMATE NOTES Sales Tax: 6.000% 5205.04 Selling Price: $3,622.32 No: 000907416 Office:Account _ .. Deliver To: Designer: Salesperson: LEIF DUNCAN -1F 165 S HIDDEN VALLEY ROAD Quote Number: 18-055892T REXBURG, ID P.O. Number: Truss Id: Span: Truss Type: Top Pit. LOH ROH Height Bot. Pit. 33-07-04 6.00 01-00-00 AOI 2x4 DF 2x4 ROOF SPECIAL 09-03-02: 158 lbs. each 3.00'. ......._._ . .. .......... .–_._.._...._.....--_ ............. _--__._,__.........__...__.......__..._.._.__.;_..........._............,_.._............._..._........,._..........._..._ 19-08-12 6.00; A02 2x4DF2x4SCISSORS 08-09-06i I t I lbs. each 3. 33-07-04: 6.00; 01-00-00 B01 2x4DF2x4 Hip 08-09-15 175 lbs. each 3.00: 33-07-04 6.00 01-00-00 I CO1 2x4 DF 2x4 HIP 07-09-15 152 Ibs. each 3.00; 33-07-04' 6.001 01-00-00 1 DOI 2x4 OF 2.4 Hip 06-09-15 160 lbs. each 3.00: ... __...... ...... _. 21-05-08 6 00 01 00-00 1 E01 2x4 DF2x4COMMON 06-02-05 991bs. each 33-07-04 6.00 01-00-00 1. G01 2x6 DF 2A HALF HIP 05-09-15 200 lbs. each 3.00 _._........... 19-08-12 6.00'; 01-00-00 411101 2x4DF2x4 SCISSOR 05-09-02 76 lbs. each 3.00 19-08-12 6.00; 01-00-00 1 ! H02 2x4 DF 2x4 GABLE 05-09-02 84 lbs. each _._.........._____............................._......._....._..i_.._._.._.._........._..__1..._..._.__..._.._...__.._...._._.._._._........__...__........_..__.._..._..�...._._..... 3.00: ' 10-00-00 6.00. 01-00-00 6 JO1 2x4DF2x4 JACK -CLOSED 05-09-15. 44 lbs. each - __ ...... .. ........ __. _..- ._....._....__ - ..._.._. ........ ... _.. 23-06-09 13 42 1 LGO1 2x4DF2x4 GABLE 07-07-06 1041bs. each Miscellaneous Items Quantity: Description: 6 LUS24IDF THIS OiTOTATION IS ONLY GOOD FOR 30 DAYS FROM DATE PRINTED TRUSS ESTIMATE NOTES Sales Tax: 6.000% 5205.04 Selling Price: $3,622.32 1800 - Rexburg LBM kAuo)oao-aLam Bid Proposal BID ID - DBW/Jim Paoworth REV 1 QUOTE 2153443 PAGE 1 OF 3 MODEL: N TERMS: CPO: EFFECTIVE DATE: 5/2/2018 SLSREP: Rexburg LBM House Account EXPIRATION DATE: 5/16/2018 ENT BY: Dallen B. Wilding WHSE: 1800 REXBURG (208)356-9292 CUSTOMER 41800 SHIP TO: COD BID COD REX 1800 COD REX 1800 COLLECT IN FULL AT DELIVERY 202 WEST MAIN 202 W MAIN REXBURG ID 83440 REXBURG ID 83440 PHONE: FAX: D... s rs _ - XT P LINE CITY •z� -.. 1 FOUNDATION MATERIALS ...••.........+. '..« 2 27.00 EA HF1S0015 FS112'ZCHEX NUT - OW 0.21 5.67 3 27.00 EA SSTBP123 SIMPSON 1/2" BEARING 0.00 1.89 51.03 4 7.00 PC TF26161AGBO TRTD FIR 2X6X16 INT ABV 112.00 1145.62MBF 128.31 5 3.00 ROLL SS51260 SILL SEAL 5-1/2X50 0.00 6.81 20.43 0.00 205.44 6 0 Subtotal 7 BASEMENT EXT WALLS .+++'*«+..... 8 16.00 PC D2616 DOUG FIR 2X6X16 #2 S4S 256.00 923.60MBF 236.44 9 120.00 PC D269258 DOUG FIR 2X6X92-5/8 960.00 626.20MBF 601.15 10 7.00 PC D66101 DOUG FIR 6X6X10 #1 S4S 210.00 2325.24MBF 488.30 11 8.00 PC D21010 DOUG FIR 2X10X10 #2 S4S 133.34 850.52MBF 113.40 12 30.00 PC OSB716 OSB 7/16 4X8 RATED 960.00 521.53MSF 500.67 13 1.00 EACH HARDWARE ALLOWANCE 0.00 500.00 500.00 0.00 2439.96 14 1 Subtotal 15 BASEMENT INTERIOR WALLS '+'+" ......« 16 4.00 PC TF24161AGBO TRTD FIR 2X4X16 INT ABV 42.67 1107.22MBF 47.24 17 8.00 PC D2416S DOUG FIR 2X4X16 STDBBTR 85.34 890.85MBF 76.02 18 66.00 PC D249258 DOUG FIR 2X4X92-5/8 STUD 351.98 588.99MBF 207.31 19 2 Subtotal 0.00 330.57 20 MAIN FLOOR FRAMING ""*''"•... ........ 21 5.00 PC TJTS114117816 TIMBERSTRAND RIMBOARD 160.00 3.14LF 251.20 22 17.00 PC TJ1110117830 TJ I JOIST 110 1-3/4" X 1020.00 1 1.65LF 841.50 23 44.00 LF TJLVLES1178 TJLVL 1-3/4X11-7/8 88.00 4.84 212.96 2122 24 32.00 LF TJLVLESI6 TJLVL 1-3/4X16 85.34 7.18 229.76 2116 25 34.00 EA SSTIUS1811188 SIMPSON 1-3/4X11-7/8 0.00 3.64 123.76 26 35.00 PC OSB2332SFTG OSB 23132 4X8 1120.00 779.48MSF 673.02 27 10.00 EA DAP25117 DAP 25117 4000 SUBFLOOR 0.00 4.99 49.90 28 1.00 EACH HARDWARE ALLOWANCE 0.00 500.00 500.00 29 3 Subtotal 0.00 3082.10 30 MAIN EXTERIOR WALLS ""..... """"" 31 384.00 LF D26T2 DOUG FIR 2X6 #2 S4S 384.00 870.42MBF 334.24 32 150.00 PC D269258 DOUG FIR 2X6X92-5/8 1200.00 626.20MBF 751.44 DBW/Jim Papworth1