HomeMy WebLinkAboutRESCHECK - 18-00219 - 273 Rebecca Ave - AdditionfZGenerated by REScheck-Web Software Compliance Certificate Project Aaron Schellenber Home Addition (273 Rebecca Ave) Energy Code: 2015 IECC Location: Rexburg, Idaho Construction Type: Single-family Project Type: Addition Orientation: Bldg. faces 180 deg. from North Climate Zone: 6 (8693 HDD) Permit Date: Permit Number: Construction Site: 273 REBECCA AVE. REXBURG, ID 83440 Owner/Agent: Aaron Schellenberg Owner of the residence 273 REBECCA AVE. REXBURG, ID 83440 208-201-4639 schelienberga@byui.edu Designer/Contractor: Aaron Schellenberg Owner of the residence 273 REBECCA AVE. REXBURG, ID 83440 schellenberga@byui.edu Compliance: 1.1% Better Than Code Maximum UA: 262 Your UA: 259 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies Ceiling: Flat Ceiling or Scissor Truss 806 49.0 0.0 0.026 21 Wall: Wood Frame, 16" D.E. 589 19.0 5.0 0.045 20 Orientation: Front Door: Solid Door (under 50% glazing) 20 0.270 5 Orientation: Front Door: Solid Door (under 50% glazing) 20 0.270 5 Orientation: Front Door: Solid Door (under 50% glazing) 20 0.210 4 Orientation: Front Window: Vinyl Frame 20 0.300 6 Orientation: Front Window: Vinyl Frame 20 0.300 6 Orientation: Front Window: Vinyl Frame 20 0.300 6 Orientation: Front Window: Vinyl Frame 9 0.300 3 Orientation: Front Window: Vinyl Frame 9 0.300 3 Orientation: Front Wall: Wood Frame, 16" o.c. 494 19.0 5.0 0.045 20 Orientation: Right side Window: Vinyl Frame 20 0.300 6 Orientation: Right side Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18 Data filename: Page 1 of 10 Orientation: Right side Wall: Wood Frame, 16" ox. 589 19.0 5.0 0.045 23 Orientation: Back Door: Solid Door (under 50% glazing) 20 0.270 5 Orientation: Back Window: Vinyl Frame 20 0.300 6 Orientation: Back Window: Vinyl Frame 20 0.300 6 Orientation: Back Window: Vinyl Frame 9 0.300 3 Orientation: Back Window: Vinyl Frame 9 0.300 3 Orientation: Back Wall: wood Frame, 16" o.c. 494 19.0 5.0 0.045 22 Orientation: Left side Floor: Slab -On -Grade (Unheated) 114 7.7 0.706 80 Insulation depth: 4.0' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. - Title Signature Date Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18 Data filename: Page 2 of 10 CREScheck Software Version : REScheck-Web �J( Inspection Checklist Energy Code: 2015 IECC Requirements: 62.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section # Pre-Inspection/Plan Review Plans Verified Field Verified Complies? Comments/Assumptions & Re .ID value Value 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate []Does Not [PRl)r energy code compliance for the ❑Not Observable building envelope. Thermal ❑Not Applicable envelope represented on construction documents. 103.1, Construction drawings and ❑Complies Requirement will be met. 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for ❑Not Observable [PR311 lighting and mechanical systems. ❑Not Applicable 10* Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies Requirement will be met. 403.7 sized per ACCA Manual 5 based Btu/hr Btu/hr— ❑Does Not [PR2)2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods Btu/hr Btu/hr ❑Not Applicable approved by the code official. _ Additional Comments/Assumptions: 1 I High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 13 ILow Impact (Tier 3) Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18 Data filename: Page 3 of 10 Section # Foundation Inspection Plans Verified Value Field Verlfled value Complies? Comments/Assumptions & Req.ID 402.1.2 Slab edge insulation R -value. R- R- ❑Complies See the Envelope Assemblies [F0111 ❑ Unheated ❑Unheated ❑Does Not table for values. qJ ❑ Heated ❑ Heated [-]Not Observable ❑Not Applicable 402.1.2 Slab edge insulation ❑Complies See the Envelope Assemblies [F031' depth/length. _ft _ft []Does Not table for values. ,U []Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [F01112 to protect exposed exterior ❑Does Not ur insulation and extends a ❑Not Observable minimum of 6 in. below grade. ❑Not Applicable 403.9 Snow- and ice -melting system ❑Complies Exception: Requirement is [F01212 controls installed. ❑Does Not not applicable. U, ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 2 J Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18 Data filename: Page 4 of 10 Section # Framing / Rough -In Inspection Plans Verified Field Verified Compiles? Comments/Assumptions & Re .ID Value Value 402.1.1, Door U -factor. U- U-_ ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FRI]' []Not Observable 0 ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U-_ U -_❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 ❑Not Observable [FR2]1 ❑Not Applicable 0 303.1.3 U -factors of fenestration products ❑Complies [FR411 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not ,. -instructions. []Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20)' is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/1.5.2/A440 ❑Not Observable 14 or has infiltration rates per NFRC ❑Not Applicable 400 that do not exceed code limits. 402.4.5 IC -rated recessed lighting fixtures ❑Complies [FR16]2 'sealed at housing/interior finish ❑Does Not and labeled to indicate 52.0 cfm ❑Not Observable leakage at 75 Pa ❑Not Applicable 403.3.1 Supply and return ducts in attics ❑Complies Exception: Ducts located [FR12]1 insulated >= R-8 where duct is ❑Does Not completely inside the >= 3 inches in diameter and >_ ❑Not Observable building envelope. R-6 where < 3 inches. Supply and ❑Not Applicable return ducts in other portions of the building insulated >= R-6 for diameter >- 3 inches and R-4.2 for < 3 inches in diameter. 403.3.5. Building cavities are not used as ❑Complies Requirement will be met. [FR15]1 ducts or plenums. ❑Does Not :14 ❑Not Observable.. ❑Not Applicable 403.4 HVAC piping conveying fluids R- R-_ ❑Complies Exception: Requirement is [FR1712 above 105 4F or chilled fluids ❑Does Not not applicable. ,1 below 55 QF are insulated to aR- ❑Not Observable 3. ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies Exception: Requirement is [FR24]1 piping. ❑Does Not not applicable. dJ ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R-_ R- ❑Complies Exception: Requirement is [FR1812 aR-3. ❑Does Not not applicable. J ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR1912 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18 Data filename: Page 5 of 10 Additional Comments/Assumptions: 1 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18 Data filename: Page 6 of 10 Section # Insulation Inspection Plans Vered Field Verified Compiles? Comments/Assumptions & Re .ID Value Value 303.1 All installed insulation is labeled ❑Complies [IN13]1 or the installed R -values ❑Does Not 40, provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R -value. If this is a R- R-_ ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall E] Mass E] mass ❑Not Observable (IN311 exterior, the exterior insulation ❑ Steel ❑ Steel ❑Not Applicable 4 requirement applies (FR10). 303.2 Wall insulation is installed per "❑Complies [IN411 manufacturer's instructions.❑Does Not i❑Not Observable `;❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18 Data filename: Page 7 of 10 Section # Final Inspection Provisions Plans Verified Value Field Verified Value Compliest Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R -value. R-_ R- ❑Complies See the Envelope Assemblies 402.2.1, E] Wood F1 Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel []Not402.2.6 Not Observable [Fill' ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions.❑Does Not [FI211 Blown insulation marked every Observable 300 ft'.❑Not ❑Not Applicable 402.2.3 Vented attics with air permeable;❑Complies [FI22]2 insulation include baffle adjacent❑Does Not to soffit and eave vents that -0Not Observable extends over insulation. -❑Not Applicable 402.2.4 Attic access hatch and door R-_ R- ❑Complies [FI311 insulation ;-R-value of the ❑Does Not adjacent assembly. []Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50=_ ❑Complies [FI1711 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. []Not Observable ❑Not Applicable 403.3.4 Duct tightness test result of <=4 cfm/100 cfm/100 ❑Complies Exception: All ducts and air [FI411 cfm/100 ft2 across the system or ft2 ft' ❑Does Not handlers are located within <=3 cfm/100 ft2 without air ❑Not Observable conditioned space. . handler @ 25 Pa. For rough -in ❑Not Applicable tests, verification may need to - occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies : Exception: All ducts and air [F12711 determine air leakage with ft2 T ❑Does Not handlers are located within either: Rough -in test: Total : []Not Observable conditioned space. leakage measured with a . pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a '.. pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated❑Complies Exception: Requirement is [FI2411 by manufacturer at <=2% of ?❑Does Not not applicable. design air flow.❑Not Observable `!❑Not Applicable 403.1.1 Programmable thermostats -i❑Complies Requirement will be met. [Flgh installed for control of primary❑Does Not heating and cooling systems and '❑Not Observable initially set by manufacturer to �❑Not Applicable code specifications. 403.1.2 Heat pump thermostat installed %❑Complies Exception: Requirement is [FI10]2 on heat pumps. ''❑Does Not not applicable. ❑Not Observable -:❑Not Applicable 403.5.1 Circulating service hot water ❑Complies Exception: Requirement is [F1 11]2 systems have automatic or ❑Does Not not applicable. accessible manual controls. ❑Not Observable []Not Applicable 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18 Data filename: Page 8 of 10 Section # Final Inspection Provisions Plans Verified Field Verified Complies? Comments/Assumptions & Re .ID Value Value 403.6.1 All mechanical ventilation system ❑Complies Exception: Requirement is [F12512 fans not part of tested and listed []Does Not not applicable. HVAC equipment meet efficacy ❑Not Observable and air flow limits. ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies Exception: Requirement is [FI2612 through one- or two -pipe heating ❑Does Not not applicable. systems have outdoor setback ❑Not Observable control to lower boiler water ❑Not Applicable temperature based on outdoor temperature. 403.5.1.1 Heated water circulation systems ! []Complies Exception: Requirement is [Ff28]2 have a circulation pump. The `,❑Does Not not applicable. system return pipe is a dedicated❑Not Observable return pipe or a cold water supply -❑Not Applicable pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set -point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems Exception: Requirement is [FI29]2 comply with IEEE 515.1 or UL -''''"❑Complies ` ❑Does Not not applicable. 515. Controls automatically !❑Not Observable adjust the energy input to the .❑Not Applicable heat tracing to maintain the desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies Exception: Requirement is [F13012 have recirculation pumps that J❑Does Not not applicable. pump water from a heated water '❑Not Observable supply pipe back to the heated Applicable water source through a cold❑Not water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1044F. 403.5.4 Drain water heat recovery units ❑Complies Exception: Requirement is (F13 1]2 tested in accordance with CSA ❑Does Not not applicable. B55.1. Potable water -side ❑Not Observable pressure loss of drain water heat ❑Not Applicable recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75% of lamps in permanent ❑Complies Requirement will be met. (F1611 fixtures or 75% of permanent ❑Does Not fixtures have high efficacy lamps. ❑Not Observable Does not apply to low -voltage ❑Not Applicable lighting. 404.1.1 Fuel gas lighting systems have ❑Complies Requirement will be met. [FI2313 no continuous pilot light. []Does Not 'J ❑Not Observable ❑Not Applicable 11 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18 Data filename: Page 9 of 10 oaction ft & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies? Comments/Assumptions 401.3 Compliance certificate posted. []Complies [F1712 []Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies Requirement will be met. [FI1813 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 JlLow Impact (Tier 3) Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18 Data filename: Page 10 of 10 �J(2015 IECC Energy Efficiency Certificate Insulation Rating R -Value Above -Grade Wall 24.00 Below -Grade Wall 0.00 Floor 7.70 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Glass & Door Rating U -Factor SHGC Window 0.30 Door 0.27 Heating Systen Cooling System Water Heater: Name: Date: Comments