Compliance Certificate
Project Aaron Schellenber Home Addition (273 Rebecca Ave)
Energy Code:
2015 IECC
Location:
Rexburg, Idaho
Construction Type:
Single-family
Project Type:
Addition
Orientation:
Bldg. faces 180 deg. from North
Climate Zone:
6 (8693 HDD)
Permit Date:
Permit Number:
Construction Site:
273 REBECCA AVE.
REXBURG, ID 83440
Owner/Agent:
Aaron Schellenberg
Owner of the residence
273 REBECCA AVE.
REXBURG, ID 83440
208-201-4639
schelienberga@byui.edu
Designer/Contractor:
Aaron Schellenberg
Owner of the residence
273 REBECCA AVE.
REXBURG, ID 83440
schellenberga@byui.edu
Compliance: 1.1% Better Than Code Maximum UA: 262 Your UA: 259
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home.
Envelope Assemblies
Ceiling: Flat Ceiling or Scissor Truss
806 49.0
0.0 0.026
21
Wall: Wood Frame, 16" D.E.
589 19.0
5.0 0.045
20
Orientation: Front
Door: Solid Door (under 50% glazing)
20
0.270
5
Orientation: Front
Door: Solid Door (under 50% glazing)
20
0.270
5
Orientation: Front
Door: Solid Door (under 50% glazing)
20
0.210
4
Orientation: Front
Window: Vinyl Frame
20
0.300
6
Orientation: Front
Window: Vinyl Frame
20
0.300
6
Orientation: Front
Window: Vinyl Frame
20
0.300
6
Orientation: Front
Window: Vinyl Frame
9
0.300
3
Orientation: Front
Window: Vinyl Frame
9
0.300
3
Orientation: Front
Wall: Wood Frame, 16" o.c.
494 19.0
5.0 0.045
20
Orientation: Right side
Window: Vinyl Frame
20
0.300
6
Orientation: Right side
Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18
Data filename: Page 1 of 10
Orientation: Right side
Wall: Wood Frame, 16" ox.
589 19.0
5.0 0.045
23
Orientation: Back
Door: Solid Door (under 50% glazing)
20
0.270
5
Orientation: Back
Window: Vinyl Frame
20
0.300
6
Orientation: Back
Window: Vinyl Frame
20
0.300
6
Orientation: Back
Window: Vinyl Frame
9
0.300
3
Orientation: Back
Window: Vinyl Frame
9
0.300
3
Orientation: Back
Wall: wood Frame, 16" o.c.
494 19.0
5.0 0.045
22
Orientation: Left side
Floor: Slab -On -Grade (Unheated)
114
7.7 0.706
80
Insulation depth: 4.0'
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection
Checklist.
- Title Signature Date
Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18
Data filename: Page 2 of 10
CREScheck Software Version : REScheck-Web
�J( Inspection Checklist
Energy Code: 2015 IECC
Requirements: 62.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
section
#
Pre-Inspection/Plan Review
Plans Verified
Field Verified
Complies?
Comments/Assumptions
& Re .ID
value
Value
103.1,
Construction drawings and
❑Complies
103.2
documentation demonstrate
[]Does Not
[PRl)r
energy code compliance for the
❑Not Observable
building envelope. Thermal
❑Not Applicable
envelope represented on
construction documents.
103.1,
Construction drawings and
❑Complies
Requirement will be met.
103.2,
documentation demonstrate
❑Does Not
403.7
energy code compliance for
❑Not Observable
[PR311
lighting and mechanical systems.
❑Not Applicable
10*
Systems serving multiple
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1,
Heating and cooling equipment is
Heating:
Heating:
❑Complies
Requirement will be met.
403.7
sized per ACCA Manual 5 based
Btu/hr
Btu/hr—
❑Does Not
[PR2)2
on loads calculated per ACCA
Cooling:
Cooling:
❑Not Observable
Manual J or other methods
Btu/hr
Btu/hr
❑Not Applicable
approved by the code official.
_
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 13 ILow Impact (Tier 3)
Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18
Data filename: Page 3 of 10
Section
#
Foundation Inspection
Plans Verified
Value
Field Verlfled
value
Complies?
Comments/Assumptions
& Req.ID
402.1.2
Slab edge insulation R -value.
R-
R-
❑Complies
See the Envelope Assemblies
[F0111
❑ Unheated
❑Unheated
❑Does Not
table for values.
qJ
❑ Heated
❑ Heated
[-]Not Observable
❑Not Applicable
402.1.2
Slab edge insulation
❑Complies
See the Envelope Assemblies
[F031'
depth/length.
_ft
_ft
[]Does Not
table for values.
,U
[]Not Observable
❑Not Applicable
303.2.1
A protective covering is installed
❑Complies
[F01112
to protect exposed exterior
❑Does Not
ur
insulation and extends a
❑Not Observable
minimum of 6 in. below grade.
❑Not Applicable
403.9
Snow- and ice -melting system
❑Complies
Exception: Requirement is
[F01212
controls installed.
❑Does Not
not applicable.
U,
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 2 J Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18
Data filename: Page 4 of 10
Section
#
Framing / Rough -In Inspection
Plans Verified
Field Verified
Compiles?
Comments/Assumptions
& Re .ID
Value
Value
402.1.1,
Door U -factor.
U- U-_
❑Complies
See the Envelope Assemblies
402.3.4
❑Does Not
table for values.
[FRI]'
[]Not Observable
0
❑Not Applicable
402.1.1,
Glazing U-factor(area-weighted
U-_ U -_❑Complies
See the Envelope Assemblies
402.3.1,
average).
❑Does Not
table for values.
402.3.3,
402.5
❑Not Observable
[FR2]1
❑Not Applicable
0
303.1.3
U -factors of fenestration products
❑Complies
[FR411
are determined in accordance
❑Does Not
with the NFRC test procedure or
❑Not Observable
taken from the default table.
❑Not Applicable
402.4.1.1
Air barrier and thermal barrier
❑Complies
[FR23]1
installed per manufacturer's
❑Does Not
,.
-instructions.
[]Not Observable
❑Not Applicable
402.4.3
Fenestration that is not site built
❑Complies
[FR20)'
is listed and labeled as meeting
❑Does Not
AAMA/WDMA/CSA 101/1.5.2/A440
❑Not Observable
14
or has infiltration rates per NFRC
❑Not Applicable
400 that do not exceed code
limits.
402.4.5
IC -rated recessed lighting fixtures
❑Complies
[FR16]2
'sealed at housing/interior finish
❑Does Not
and labeled to indicate 52.0 cfm
❑Not Observable
leakage at 75 Pa
❑Not Applicable
403.3.1
Supply and return ducts in attics
❑Complies
Exception: Ducts located
[FR12]1
insulated >= R-8 where duct is
❑Does Not
completely inside the
>= 3 inches in diameter and >_
❑Not Observable
building envelope.
R-6 where < 3 inches. Supply and
❑Not Applicable
return ducts in other portions of
the building insulated >= R-6 for
diameter >- 3 inches and R-4.2
for < 3 inches in diameter.
403.3.5.
Building cavities are not used as
❑Complies
Requirement will be met.
[FR15]1
ducts or plenums.
❑Does Not
:14
❑Not Observable..
❑Not Applicable
403.4
HVAC piping conveying fluids
R- R-_
❑Complies
Exception: Requirement is
[FR1712
above 105 4F or chilled fluids
❑Does Not
not applicable.
,1
below 55 QF are insulated to aR-
❑Not Observable
3.
❑Not Applicable
403.4.1
Protection of insulation on HVAC
❑Complies
Exception: Requirement is
[FR24]1
piping.
❑Does Not
not applicable.
dJ
❑Not Observable
❑Not Applicable
403.5.3
Hot water pipes are insulated to
R-_ R-
❑Complies
Exception: Requirement is
[FR1812
aR-3.
❑Does Not
not applicable.
J
❑Not Observable
❑Not Applicable
403.6
Automatic or gravity dampers are
❑Complies
[FR1912
installed on all outdoor air
❑Does Not
intakes and exhausts.
❑Not Observable
❑Not Applicable
1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18
Data filename: Page 5 of 10
Additional Comments/Assumptions:
1 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18
Data filename: Page 6 of 10
Section
#
Insulation Inspection
Plans Vered
Field Verified
Compiles?
Comments/Assumptions
& Re .ID
Value
Value
303.1
All installed insulation is labeled
❑Complies
[IN13]1
or the installed R -values
❑Does Not
40,
provided.
❑Not Observable
❑Not Applicable
402.1.1,
Wall insulation R -value. If this is a
R-
R-_
❑Complies See the Envelope Assemblies
402.2.5,
mass wall with at least 1/2 of the
❑ Wood
❑ Wood
❑Does Not table for values.
402.2.6
wall insulation on the wall
E] Mass
E] mass
❑Not Observable
(IN311
exterior, the exterior insulation
❑ Steel
❑ Steel
❑Not Applicable
4
requirement applies (FR10).
303.2
Wall insulation is installed per
"❑Complies
[IN411
manufacturer's instructions.❑Does
Not
i❑Not Observable
`;❑Not
Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18
Data filename: Page 7 of 10
Section
#
Final Inspection Provisions
Plans Verified
Value
Field Verified
Value
Compliest
Comments/Assumptions
& Req.ID
402.1.1,
Ceiling insulation R -value.
R-_ R-
❑Complies
See the Envelope Assemblies
402.2.1,
E] Wood F1 Wood
❑Does Not
table for values.
402.2.2,
❑ Steel ❑ Steel
[]Not402.2.6 Not Observable
[Fill'
❑Not Applicable
303.1.1.1,
Ceiling insulation installed per
❑Complies
303.2
manufacturer's instructions.❑Does
Not
[FI211
Blown insulation marked every
Observable
300 ft'.❑Not
❑Not Applicable
402.2.3
Vented attics with air permeable;❑Complies
[FI22]2
insulation include baffle adjacent❑Does
Not
to soffit and eave vents that
-0Not
Observable
extends over insulation.
-❑Not Applicable
402.2.4
Attic access hatch and door
R-_ R-
❑Complies
[FI311
insulation ;-R-value of the
❑Does Not
adjacent assembly.
[]Not Observable
❑Not Applicable
402.4.1.2
Blower door test @ 50 Pa. <=5
ACH 50 = ACH 50=_
❑Complies
[FI1711
ach in Climate Zones 1-2, and
❑Does Not
<=3 ach in Climate Zones 3-8.
[]Not Observable
❑Not Applicable
403.3.4
Duct tightness test result of <=4
cfm/100 cfm/100
❑Complies
Exception: All ducts and air
[FI411
cfm/100 ft2 across the system or
ft2 ft'
❑Does Not
handlers are located within
<=3 cfm/100 ft2 without air
❑Not Observable
conditioned space.
. handler @ 25 Pa. For rough -in
❑Not Applicable
tests, verification may need to
-
occur during Framing Inspection.
403.3.3
Ducts are pressure tested to
cfm/100 cfm/100
❑Complies
: Exception: All ducts and air
[F12711
determine air leakage with
ft2 T
❑Does Not
handlers are located within
either: Rough -in test: Total
:
[]Not Observable
conditioned space.
leakage measured with a
. pressure differential of 0.1 inch
❑Not Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test: Total
leakage measured with a
'..
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1
Air handler leakage designated❑Complies
Exception: Requirement is
[FI2411
by manufacturer at <=2% of
?❑Does Not
not applicable.
design air flow.❑Not
Observable
`!❑Not Applicable
403.1.1
Programmable thermostats
-i❑Complies
Requirement will be met.
[Flgh
installed for control of primary❑Does
Not
heating and cooling systems and
'❑Not Observable
initially set by manufacturer to
�❑Not Applicable
code specifications.
403.1.2
Heat pump thermostat installed
%❑Complies
Exception: Requirement is
[FI10]2
on heat pumps.
''❑Does Not
not applicable.
❑Not Observable
-:❑Not Applicable
403.5.1
Circulating service hot water
❑Complies
Exception: Requirement is
[F1 11]2
systems have automatic or
❑Does Not
not applicable.
accessible manual controls.
❑Not Observable
[]Not Applicable
11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18
Data filename: Page 8 of 10
Section
#
Final Inspection Provisions
Plans Verified
Field Verified
Complies?
Comments/Assumptions
& Re .ID
Value
Value
403.6.1
All mechanical ventilation system
❑Complies
Exception: Requirement is
[F12512
fans not part of tested and listed
[]Does Not
not applicable.
HVAC equipment meet efficacy
❑Not Observable
and air flow limits.
❑Not Applicable
403.2
Hot water boilers supplying heat
❑Complies
Exception: Requirement is
[FI2612
through one- or two -pipe heating
❑Does Not
not applicable.
systems have outdoor setback
❑Not Observable
control to lower boiler water
❑Not Applicable
temperature based on outdoor
temperature.
403.5.1.1
Heated water circulation systems
! []Complies
Exception: Requirement is
[Ff28]2
have a circulation pump. The
`,❑Does Not
not applicable.
system return pipe is a dedicated❑Not
Observable
return pipe or a cold water supply
-❑Not Applicable
pipe. Gravity and thermos-
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set -point temperature and
no demand for hot water exists.
403.5.1.2
Electric heat trace systems
Exception: Requirement is
[FI29]2
comply with IEEE 515.1 or UL
-''''"❑Complies
` ❑Does Not
not applicable.
515. Controls automatically
!❑Not Observable
adjust the energy input to the
.❑Not Applicable
heat tracing to maintain the
desired water temperature in the
piping.
403.5.2
Water distribution systems that
❑Complies
Exception: Requirement is
[F13012
have recirculation pumps that
J❑Does Not
not applicable.
pump water from a heated water
'❑Not Observable
supply pipe back to the heated
Applicable
water source through a cold❑Not
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 1044F.
403.5.4
Drain water heat recovery units
❑Complies
Exception: Requirement is
(F13 1]2
tested in accordance with CSA
❑Does Not
not applicable.
B55.1. Potable water -side
❑Not Observable
pressure loss of drain water heat
❑Not Applicable
recovery units < 3 psi for
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
404.1
75% of lamps in permanent
❑Complies
Requirement will be met.
(F1611
fixtures or 75% of permanent
❑Does Not
fixtures have high efficacy lamps.
❑Not Observable
Does not apply to low -voltage
❑Not Applicable
lighting.
404.1.1
Fuel gas lighting systems have
❑Complies
Requirement will be met.
[FI2313
no continuous pilot light.
[]Does Not
'J
❑Not Observable
❑Not Applicable
11 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18
Data filename: Page 9 of 10
oaction
ft
& Req.ID
Final Inspection Provisions
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
401.3
Compliance certificate posted.
[]Complies
[F1712
[]Does Not
❑Not Observable
❑Not Applicable
303.3
Manufacturer manuals for
❑Complies Requirement will be met.
[FI1813
mechanical and water heating
❑Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 JlLow Impact (Tier 3)
Project Title: Aaron Schellenber Home Addition (273 Rebecca Ave) Report date: 04/28/18
Data filename: Page 10 of 10
�J(2015 IECC Energy
Efficiency Certificate
Insulation Rating R -Value
Above -Grade Wall 24.00
Below -Grade Wall 0.00
Floor 7.70
Ceiling / Roof 49.00
Ductwork (unconditioned spaces):
Glass & Door Rating U -Factor SHGC
Window 0.30
Door 0.27
Heating Systen
Cooling System
Water Heater:
Name: Date:
Comments