Loading...
HomeMy WebLinkAboutRESCHECK - 18-00205 - 677 Wheatland Cir - New SFR1ZGenerated by REScheck-Web Software Compliance Certificate Project Kohler House Plan Energy Code: 2015 IECC Location: Rexburg, Idaho Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 7,028 ft2 Glazing Area 13% Climate Zone: 6 (8693 HDD) Permit Date: 72 Permit Number: justin@stevenshomes.com I&-oozos Construction Site: Owner/Agent: Designer/Contractor: 651 Wheatland Mark Kohler Justin Stevens Rexburg, ID 83440 Rexburg, ID 83440 Stevens Homes 122 72 PO Box 2759 0.130 Idaho Falls, ID 83403 72 justin@stevenshomes.com trade-offCompliance: Passes using LIA Compliance: 1.2% Better Than Cattle Maximum UA: 660 Your UA: 652 The %B¢neror Worse Than Cotle Inpez reflects Iqw doae to mmplianCe the house Is based on code tratlhan odes. It DoesnpT provide an eadmate of energy use or cost relasive to a minimum-cMe home. Envelope Assemblies Ceiling: Flat Ceiling or Scissor Truss Main Floor Walls: Wood Frame, 16" o.c. Door: Solid Door (under 50% glazing) Door Main Floor: Glass Door (over 50% glazing) Window Main Floor: Vinyl Frame Second Floor Walls copy: Wood Frame, 16" o.c. Door: Glass Door (over 50% glazing) Window Second Floor: Vinyl Frame Basement Wall: Solid Concrete or Masonry Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 8.0' Crawl: Solid Concrete or Masonry Wall height: 4.0' Depth below grade: 3.0' Insulation depth: 3.0' 2,827 50.0 0.0 0.026 74 2,800 19.0 2.0 0.053 122 72 0.130 9 72 0.270 19 358 0.270 97 3,200 19.0 2.0 0.053 150 72 0.270 19 298 0.270 80 1,072 13.0 2.0 0.057 61 564 19.0 2.0 0.050 21 Project Title: Kohler House Plan Report date: 04/19/18 Data filename: Page 1 of 10 V2015 IECC Energy (j Efficiency Certificate Insulation Rating R -Value Above -Grade Wall 21.00 Below -Grade Wall 15.00 Floor 0.00 Ceiling / Roof 50.00 Ductwork (unconditioned spaces): Window 0.27 Door 0.27 Heating System: Cooling System: Water Heater: Name: Date: Comments Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 20151ECC requirements in REScheck Version : REScheck-Web and to comply with the map4irt Arequiremengs listegd In the RE5check Inspection Checklist. Project Title: Kohler House Plan Report date: 04/19/18 Data filename: Page 2 of10 ^� REScheck Software Version : REScheck-Web I/ Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions' column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Pre-Inspectlon/Plan Review Plans Verified value Field Verified Value Complies? Comments/Assumptlons & Re .ID 103.1, Construction drawings and [Complies 103.2 documentation demonstrate []Does Not [PRI]' energy code compliance for the y building envelope. Thermal []Not Observable envelope represented on []Not Applicable construction documents. 103.1, Construction drawings and [Complies 103.2, documentation demonstrate [Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. [No[ Observable Systems serving multiple [Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Healing: Heating: [Complies 403.7 sized per ACCA Manual S based Btu/hr CDoes Not [P]121� on loads calculated per ACCA —Btu/hr_ Cooling: Cooling: ❑Not Observable Manual] or other methods approved by the code official. Btu/hr Btu/hr .[]Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) Lld Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Kohler House Plan Report date: 04/19/18 Data filename: Page 3 of10 Section # Foundation Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions & Ra .ID 402.1.1 Conditioned basement wall R- R- []Complies See the Envelope Assemblies [F0411 insulation R -value. Where interior R- R- [Does Not table Por values, insulation is used, verification may need to occur during []Not Observable Insulation Inspection. Not []Not Applicable required in warm -humid locations In Climate Zone 3. 303.2 Conditioned basement wall []Complies [F051r insulation Installed per ❑Does Not 0 manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall f[ ft []Complies 'See the Envelope Assemblles [FO6]' insulation depth of burial or []Does Not table for values. B distance from top of wall. []Not Observable []Not Applicable 402.2.11 Unvented crawl space wall R- R-_ []Complies see the Envelope Assemblies [F0711 insulation R-valueor R-_ R-_ []Does Not table fvalues. 0 []Not Observable Applicable 303.2 Unvented crawl space wall _ONot []Complies [F08p insulation installed per []Does Not 0 manufacturer's instructions. []Not Observable []Not Applicable 402.2.11 Unventedcrawl space continuous []Complies [FO91r vapor retarder installed over []Does Not O exposed earth, joints overlapped by 61n. and sealed, extending at []Not Observable least 6 in. up and attached to the []Not Applicable wall. 402.2.11 Unvented crawl space wall in. in. []Complies See the Envelope Assemblies [FO10P insulation depth of burial or []Does Not table for values 9 distance from top of wall. ONot Observable []Not Applicable 303.2.1 A protective covering Is installed []Complies [F011]2 to protect exposed exterior ❑Does Not V, insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 Snow- and Ice -melting system []Complies [FO12F controls installed. []Does Not M []Not Observable []Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) In Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Kohler House Plan Report date: 04/19/18 Data filename: Page 4 of1O Section # Framing /Rough -In Inspection Plans yerlfled value FieldyerIfI d Value Complies? 'Assumptions 402.1.1, 402.1.1, Door U -factor. U-_ U- []complies See the Envelope Assemblies 402.3.4 []Does Not table for values [FR171 []Not Observable []Not Applicable 402.1.1, Gla2Ing U-factor(area-weighted U-_ U- OComplies see the envelope Assemblles 402.3.1, average). []Does Not table for values 402.3.3, 402.5 []Not Observable [FR21t []Not Applicable 0 303.1.3 U -factors of fenestration products 11Complies [FR41t are determined In accordance ❑Does Not Q with the NFRC test procedure or taken from the default table. Nat Observable []Not Applicable 402.4.1.1 Air barrier and thermal bander OComplies [FR23]1 installed per manufacturer's []DOES Not ® instructions. ❑Not Observable ONot Applicable 402.4.3 Fenestration that is not site built []Complies [FR201t is listed and labeled as meeting QDoes Not 9 AAMA MDMA/CSA 101/1.5.2/A440 ONot Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC -rated recessed lighting fixtures OComplies [FR161� sealed at housing/interior finish ❑Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. ❑Not Observable ONot Applicable 403.3.1 Supply and return ducts in attics OComplies [FR1211 insulated >= R-8 where duct is QDoes Not Y >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and ONot Observable return ducts in other portions of []Nat Applicable the building insulated >= R-6 for diameter >= 3 Inches and R-4.2 for < 3 inches in diameter. 403.3.5 .Building cavities are not used as OComplies [FR351" ducts or plenums. ❑Does Not 'g ONot Observable ❑Not Applicable 40314'- HVAC piping conveying fluids R-_ R-_ El plies [FR1712 above 105 sF or chilled fluids []Does Not below 55 of are insulated to >_R- 3 ❑Nat Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC - _ DComplies [FR2411 piping. []Does Not y ONot Observable ONot Applicable 403.5.3 Hot water pipes are Insulated to R- R- OComplies [FR38)' aR-3. QDoes Not b ONot Observable ONot Applicable 403.6 Automatic or gravity dampers are []Complies [FR19[2 installed on all outdoor air []Does Not intakes and exhausts. ONot Observable []Not Applicable 111 High Impact (Tier 1) Medium Impact (Her 2) 1,,3 1 Low Impact (Tier 3) Project Title: Kohler House Plan Report date: 04/19/18 Data filename: Page 5 of10 Additional Comments/Assumptions: 111 High Impact (Tier 1) IN Medium Impact (Tier 2) 13,1 Low Impact (Tier 3) Project Title: Kohler House Plan Report date: 04/19/18 Data filename: Page 6 of 10 Section # Insulation Inspection plans VerRletl Fieltl VerHied Complies? Comments/Assumptions F Re .ID value Value 303.1 All installed Insulation is labeled OCor-plies [IN13? or the Installed R -values ❑Does Not Y provided. []Not Observable ❑Not Applicable 402.1.1, Wall insulation R -value. If this is a R- R- OComplles See the Envelope Assemblies 402.2.5, mass wall with at least % of the ] Wood ❑ Wood ❑Does Not table for values. 402.2.6 [IN3]1 wall Insulation on the wall exterior, the exterior insulation Mass E] Mass []Not Observable y requirement applies(FR10). ❑ Steel ❑ Steel []Not Applicable 303.2 Wall insulation is installed per OComplles [IN4]1 manufacturer's instructions. []Does Not ,[]Not Observable ONot Applicable Addltlonal Comments/Assumptions: 1 1HIgh Impact (Tier 1) JUMedlUrn Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Kohler House Plan Report date: 04/19/18 Data filename: Page 7 of10 Section # Final Inspection Provisions Plans Verified Value Fleld Ver[fled Value Complies] Comments/Assumptions & Re .ID 402.1.1, Ceiling insulation R -value. R- R- OComplies See the Envelope Assemblies 402.2.1, O Wood ❑ Wood []Does Not table for values. 402.2.2• ❑ Steel ❑ Steel []Not Observable 402'2.8 []Not Applicable [FIl] 303.1.1.1, Ceiling insulation installed per OComplies 303.2 manufacturer's instructions. ODoes Not [FI21' Blown Insulation marked every ❑Not Observable 300 ft'. ❑Not Applicable 402.2.3. Vented attics with air permeable OComplies [P12212 insulation include baffle adjacent Oboes Not to soffit and eave vents that ONot Observable extends over Insulation. ONot Applicable 402.2.4 Attic access hatch and door R- R-_ OComplles [93]' insulation all -value ofthe ❑Does Not adjacent assembly. []Not Observable []Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 =_ OComplies [FI1711 ach in Climate Zones 1-2, and ODoes Not <=3 ach In Climate Zones 3-8. ONot Observable []Not Applicable 403.3.4 Duct tightness test result of <=4 cfm/100 cfm/100 OComplies [FI4]' cfm/100 ft2 across the system or ftp- iN []Does Not <=3 cfm/100 ft2 without air []Not Observable handler @ 25 Pa. For rough -in ❑Not Applicable tests, verification may need to occur during Framing Inspection. 403.3.3 Ducts are pressure tested to chn/100 cfm/100 OComplies [F127]' determine air leakage with ft2 ft, []Does Not either: Rough -in test: Total ONot Observable leakage measured with a ONot Applicable pressure differential of 0.1 inch w.g. across the system including the manufacturer's air handier enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handier leakage designated ;OComplies [FI24T by manufacturer at <=2%of �'ODoes Not design air Flow. IONot Observable ONot Applicable 403.1.1 Programmable thermostats OComplies IFI911 installed for control of primary ODoes Not heating and cooling systems and ONot Observable initially set by manufacturer to ONot Applicable code specifications. 403.1.2 Heat pump thermostat installed OComplies [FI301� on heat pumps. ODoes Not []Not Observable ONot Applicable 403.5.1 Circulating service hot water []Complies [Fill? systems have automatic or []Does Not accessible manual controls. ONot Observable ONct Applicable 111 High Impact (Tier 1) 12. Medium Impact (Ter 2) 13:'. Low Impact (Tier 3) Project Title: Kohler House Plan Report date: 04/19/18 Data filename: Page 8 of10 Section # Final Inspection Provisions Plans Verified value Field Verlfletl Value OomplesT i Comments/Assumptions 403.6.1 All mechanical ventilation system [Complies [F125]2 fans not part of tested and listed [Does Not HVAC equipment meet efficacy and air flow limits. [Not Observable ONot Applicable 403.2 Hot water boilers supplying heat .[Complies [F1261� through one- or two pipe heating ]DOeS Not systems have outdoor setback control to lower boiler water [Not Observable temperature based on outdoor [Not Applicable temperature. 403.5.1.1 Heated water circulation systems [Complies [FI2BF have a circulation pump. The ODoes Not system return pipe is a dedicated return pipe or a cold water supply ]Not Observable pipe. Gravity and thermos- [Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop Is at set -point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems [Complies [9291° comply with IEEE 515.1 or UL I[]Does Not 515. Controls automatically :[Not Observable .adjust the energy input to the heat tracing to maintain the ;]Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that :[Complies [F130]2 have recirculation pumps that ODoes Not pump water from a heated water supply pipe back to the heated ;ONot Observable water source through a cold ",[Not Applicable water supply pipe have a demand recirculation water Pumps have :4 �I system. controls that manage operation of the !+ pump and limit the temperature r� of the water entering the cold water piping to 1049F. 403.5.4 Drain water heat recovery units ]Complies [F1311� tested In accordance with CSA ]Does Not 855.1. Potable water -side pressure loss of drain water heat ]Not Observable recovery units < 3 psi for ]Nat Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75% of lamps m permanent ]Complies [F1611 fixtures or 75% of permanent [Does Not fixtures have high efficacy lamps. [No[ Observable Does not apply to low -voltage lighting. [Not Applicable 404.1.1 Fuel gas lighting systems have [Complies [1`123]3 no continuous pilot light. ]Does Not ]Not Observable ]Not Applicable 1 IHigh Impact (Tier 1) VMJ Medium Impact (Tier 2) 13 1Low Impact (Tier 3) Project Title: Kohler House Plan Report date: 04/19/18 Data filename: Page 9 of10 # Sect'onID & Re . Final Inspection Provisions plans Verified Value Field Verlf]etl Value Complies? Comments/Assumptions 401.3 Compliance certificate posted. OComplies (FD]� ODoes Not iONot Observable ONot Applicable 303.3 Manufacturer manuals for'OComplies [1`118]s mechanical and water heating ODOeS Not systems have been provided. ONot Observable iONot Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Kohler House Plan Report date: 04/19/18 Data filename: Page 10 of10