HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00107 - 565 Terra Vista Dr - SFRPermit Inspection Summary Permit Status of (Issue) as of Report Date: 04/19/2018 9:08 am Permit Details Permit Number: 13-00107 565 Terra Vista Dr. - SFR 565 TERRA VISTA DR Building - Single Family Residence Permit Issued Date: 04/03/2013 Permit Inspection Statistics 21Total Inspections Completed: 16Total Inspections Passed: Inspection Pass Rate: 76.19% Permit Inspection History *Refer to Individual Inspection Report for more Details 04/04/2013PassQuinton OwensFoundation Inspection 04/05/2013PassTed DyeFooting Inspection 04/22/2013PassDon AllenPlumbing Underground Inspection underground is all good to coverInspector Comments: 05/29/2013PassBret StoddardElectrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 07/08/2013N/ATed DyeRadon-Ground Inspection 07/30/2013PassBret StoddardElectrical Rough-in Approved for cover-called Scott and left message for short wall receptacle to be added in the southwest bedroom upstairs-will re-inspect this on the final inspection, added outlet for stairway wall spacing, added intersystem bonding termination wire. Inspector Comments: 07/31/2013FailDon AllenHVAC Rough-in need 1'' clearance around exhaust for the water heater and furnace exhaust fan needs to be put in master toilet room Inspector Comments: 07/31/2013PassDon AllenPlumbing Rough-in All good to cover the rough inInspector Comments: 08/06/2013PassTed DyeFraming/Structure Inspection Truss lateral bracing not approved yet Reference ticket Insulation 8-5-13 Inspector Comments: 09/18/2013PassDon AllenHVAC Rough-in All good to cover the rough in Gas presser held at 20 lb Inspector Comments: Basement: Stud missed some staples. Marked with red crayon on stud (on interior) Braced wall panel block missing several locations (marked with red crayon. Inspector Comments: 10/02/2013FailTed DyeFraming/Structure Inspection Framing: C-1 and c-2 missing truss tie downs B-1 and B-2 truss's missing truss tie downs. D-1 missing cross bracing(lateral bracing) E-1, E-3, and E-4 missing cross bracing (lateral bracing) Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 13-00107 565 Terra Vista Dr. - SFR 565 TERRA VISTA DR Building - Single Family Residence Permit Status of (Issue) as of Report Date: 04/19/2018 9:08 am Permit Inspection Summary 10/02/2013PassTed DyeFraming/Structure Inspection 10/02/2013PassTed DyeInsulation Inspection 10/02/2013PassTed DyeSheetrock/Drywall Inspection mostly sheet rocked had installers pull sheets off in different location to check insulation. Looked at other areas not covered basement OK **** truss lateral bracing not inspected yet. provide later at access hole. ********Noted also in framing notes****** Inspector Comments: 10/02/2013PassTed DyeSidewalk Inspection 12" Base ****Maintain a 1/4" per foot rise from curb to side walk edge Inspector Comments: All for the c/oInspector Comments: 09/02/2014PassDon AllenPlumbing Final Inspection All for the c/oInspector Comments: 09/02/2014FailDon AllenHVAC Final Inspection need to have the fire places turn onInspector Comments: Building Inspection Type -In the master bedroom the smoke detector combination CO detector should be exchanged with the smoke detector in the hall. - The grade in back should slope a minimum of 6 inches in the first 10 feet. - A landing is needed at the bottom of the stairs from the deck Inspector Comments: 09/04/2014FailTed DyeResidential Building Final On the landing at the side door of the garage there needs to be a guard rail on the north and west side of the landing Inspector Comments: 03/15/2017PassTed DyeResidential Building Final Electrical Inspection Type 09/03/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Mechanical Inspection Type 09/05/2014PassDon AllenHVAC Final Inspection All good for the c/oInspector Comments: Page 2 of 2