HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00107 - 565 Terra Vista Dr - SFRPermit
Inspection
Summary
Permit Status of (Issue) as of Report Date: 04/19/2018 9:08 am
Permit Details Permit Number: 13-00107
565 Terra Vista Dr. - SFR
565 TERRA VISTA DR
Building - Single Family Residence
Permit Issued Date: 04/03/2013
Permit Inspection Statistics
21Total Inspections Completed:
16Total Inspections Passed:
Inspection Pass Rate: 76.19%
Permit Inspection History *Refer to Individual Inspection Report for more Details
04/04/2013PassQuinton OwensFoundation Inspection
04/05/2013PassTed DyeFooting Inspection
04/22/2013PassDon AllenPlumbing Underground Inspection
underground is all good to coverInspector Comments:
05/29/2013PassBret StoddardElectrical Service Inspection
Approved to be energized for permanent power.Inspector Comments:
07/08/2013N/ATed DyeRadon-Ground Inspection
07/30/2013PassBret StoddardElectrical Rough-in
Approved for cover-called Scott and left message for short wall receptacle to be
added in the southwest bedroom upstairs-will re-inspect this on the final
inspection, added outlet for stairway wall spacing, added intersystem bonding
termination wire.
Inspector Comments:
07/31/2013FailDon AllenHVAC Rough-in
need 1'' clearance around exhaust for the water heater and furnace
exhaust fan needs to be put in master toilet room
Inspector Comments:
07/31/2013PassDon AllenPlumbing Rough-in
All good to cover the rough inInspector Comments:
08/06/2013PassTed DyeFraming/Structure Inspection
Truss lateral bracing not approved yet
Reference ticket Insulation 8-5-13
Inspector Comments:
09/18/2013PassDon AllenHVAC Rough-in
All good to cover the rough in
Gas presser held at 20 lb
Inspector Comments:
Basement: Stud missed some staples. Marked with red crayon on stud (on
interior)
Braced wall panel block missing several locations (marked with red crayon.
Inspector Comments:
10/02/2013FailTed DyeFraming/Structure Inspection
Framing: C-1 and c-2 missing truss tie downs
B-1 and B-2 truss's missing truss tie downs.
D-1 missing cross bracing(lateral bracing)
E-1, E-3, and E-4 missing cross bracing (lateral bracing)
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 13-00107
565 Terra Vista Dr. - SFR
565 TERRA VISTA DR
Building - Single Family Residence
Permit Status of (Issue) as of Report Date: 04/19/2018 9:08 am
Permit
Inspection
Summary
10/02/2013PassTed DyeFraming/Structure Inspection
10/02/2013PassTed DyeInsulation Inspection
10/02/2013PassTed DyeSheetrock/Drywall Inspection
mostly sheet rocked had installers pull sheets off in different location to check
insulation. Looked at other areas not covered
basement OK
**** truss lateral bracing not inspected yet. provide later at access hole.
********Noted also in framing notes******
Inspector Comments:
10/02/2013PassTed DyeSidewalk Inspection
12" Base
****Maintain a 1/4" per foot rise from curb to side walk edge
Inspector Comments:
All for the c/oInspector Comments:
09/02/2014PassDon AllenPlumbing Final Inspection
All for the c/oInspector Comments:
09/02/2014FailDon AllenHVAC Final Inspection
need to have the fire places turn onInspector Comments:
Building Inspection Type
-In the master bedroom the smoke detector combination CO detector should be
exchanged with the smoke detector in the hall.
- The grade in back should slope a minimum of 6 inches in the first 10 feet.
- A landing is needed at the bottom of the stairs from the deck
Inspector Comments:
09/04/2014FailTed DyeResidential Building Final
On the landing at the side door of the garage there needs to be a guard rail on
the north and west side of the landing
Inspector Comments:
03/15/2017PassTed DyeResidential Building Final
Electrical Inspection Type
09/03/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Mechanical Inspection Type
09/05/2014PassDon AllenHVAC Final Inspection
All good for the c/oInspector Comments: