Loading...
HomeMy WebLinkAboutINSPECTION TICKET SIDEWALK - 17-00413 - 636 Centennial Loop - SFRInspection Ticket Sidewalk Inspection on 04/05/2018: PASS Permit Number: 17-00413Permit Details Building - Single Family Residence Permit Issued Date: 08/08/2017 Final Inspections Required HVAC Final Inspection Plumbing Final Inspection Residential Electrical Final Inspection Residential Building Final 636 Centennial Loop 636 Centennial Loop - SFR Inspection Details larry.beesley@rexburg.org Inspected By: Larry Beesley Sidewalk Inspection on 04/05/2018: PASS D ESCRIPTIO N CO M M EN TS STATUS Ramp maximum slope of 1:12.N/A Ramp landings minimum of 60” in direction of travel. N/A Ramp maximum rise of 30”.N/A Ramps with greater than 6” rise have handrails and edge protection. N/A Ramps have a minimum width of 36” between handrails. N/A 12” gravel base is provided for sidewalks in city right-of-way. COMPLETED Sidewalk in right-of-way is formed as per plans and Rexburg Engineering requirements (min. 5’ wide with min. 7’ landscape strip). COMPLETED Slope of sidewalk used for egress access no greater than 1:20 (if greater it is a ramp). COMPLETED Cross slope of egress sidewalk maximum 1:48.COMPLETED Landings at stairs and ramps have a maximum slope of 1:48 in all directions. COMPLETED Inspector Comments The forms looked good this morning and the gravel is all in place now. You are good to pour the concrete. Thanks