HomeMy WebLinkAboutINSPECTION TICKET SIDEWALK - 17-00413 - 636 Centennial Loop - SFRInspection
Ticket
Sidewalk Inspection on 04/05/2018: PASS
Permit Number: 17-00413Permit Details
Building - Single Family Residence
Permit Issued Date: 08/08/2017
Final Inspections Required
HVAC Final Inspection Plumbing Final Inspection
Residential Electrical Final Inspection Residential Building Final
636 Centennial Loop
636 Centennial Loop - SFR
Inspection Details
larry.beesley@rexburg.org
Inspected By: Larry Beesley
Sidewalk Inspection on 04/05/2018: PASS
D ESCRIPTIO N CO M M EN TS STATUS
Ramp maximum slope of 1:12.N/A
Ramp landings minimum of 60” in direction of
travel.
N/A
Ramp maximum rise of 30”.N/A
Ramps with greater than 6” rise have handrails
and edge protection.
N/A
Ramps have a minimum width of 36” between
handrails.
N/A
12” gravel base is provided for sidewalks in city
right-of-way.
COMPLETED
Sidewalk in right-of-way is formed as per plans
and Rexburg Engineering requirements (min. 5’
wide with min. 7’ landscape strip).
COMPLETED
Slope of sidewalk used for egress access no
greater than 1:20 (if greater it is a ramp).
COMPLETED
Cross slope of egress sidewalk maximum 1:48.COMPLETED
Landings at stairs and ramps have a maximum
slope of 1:48 in all directions.
COMPLETED
Inspector Comments
The forms looked good this morning and the gravel is all in place now. You are good to pour the concrete. Thanks