Loading...
HomeMy WebLinkAboutREVIEW REPORT - BUILDING - 3-9-2018 - 17-00798 - Burton ElementaryReview Report Current Building Review Status: REVISIONS Application Number: 17-00798Permit Details Application Received Date: 12/29/2017 Commercial Addition Application Approved Date: Application Approved Status: RESUBMIT2 12/29/2017 2211 W 1000 S 2211 W 1000 S - Burton Elem. Addition Status of Plan Reviews Completed 02/22/2018Electrical Review COMPLETED 03/09/2018Building Review REVISIONS 03/09/2018Planning and Zoning Review - Site Plan COMPLETED 03/26/2018Fire Department Review - Site Plan COMPLETED 03/27/2018Public Works Review - Site Plan N/A 04/05/2018Plumbing Review COMPLETED 04/05/2018HVAC Review COMPLETED Permit Review Status Plan Reviews Still in Progress Building Review DESCRIPTION COMMENTS STA TUS *Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed! Fire walls meet the requirements of IBC Section 706 REVISIONSSheet A3.11 is missing. *Revisions Response : Ducts and dampers meet the requirements of IBC Section 717 REVISIONSFire dampers are not shown on duct penetrations at fire wall. *Revisions Response : Building complies with IECC (IBC 1301)REVISIONSR-38 in attic does not meet prescriptive requirements. Provide an energy compliance report for the addition. *Revisions Response : Occupant load is identified on plans as per IBC Section 1004 Not identified. 140 additional occupant load allowed unless calculations are otherwise submitted and approved. COMPLETED Penetrations comply with IBC Section 714 for rated assemblies Maintain fire rating at all fire wall penetrations.COMPLETED Reviewed By: Quinton Owens Review Date: 03/09/2018 Plan Review Details quinton.owens@rexburg.org Building Review Status: REVISIONS Additional Inspector Comments: Missing sheets A2.21 (Exterior Elevations) and A3.11 (Building Sections) Page 1 of 2 Approval of plans does not constitue approval of variance from code Building Review (Continued) D ESCRIPTIO N CO MMEN TS STATUS Page 2 of 2 Approval of plans does not constitue approval of variance from code Review Report Current Planning and Zoning Review - Site Plan Status: APPROVED Application Number: 17-00798Permit Details Application Received Date: 12/29/2017 Commercial Addition Application Approved Date: Application Approved Status: RESUBMIT2 12/29/2017 2211 W 1000 S 2211 W 1000 S - Burton Elem. Addition Status of Plan Reviews Completed 02/22/2018Electrical Review COMPLETED 03/09/2018Building Review REVISIONS 03/09/2018Planning and Zoning Review - Site Plan COMPLETED 03/26/2018Fire Department Review - Site Plan COMPLETED 03/27/2018Public Works Review - Site Plan N/A 04/05/2018Plumbing Review COMPLETED 04/05/2018HVAC Review COMPLETED Permit Review Status Plan Reviews Still in Progress Building Review Reviewed By: Quinton Owens Review Date: 03/09/2018 Plan Review Details quinton.owens@rexburg.org Planning and Zoning Review - Site Plan Status: APPROVED Additional Inspector Comments: Missing sheets A2.21 (Exterior Elevations) and A3.11 (Building Sections) Page 1 of 1 Approval of plans does not constitue approval of variance from code