HomeMy WebLinkAboutREVIEW REPORT - BUILDING - 3-9-2018 - 17-00798 - Burton ElementaryReview
Report
Current Building Review Status: REVISIONS
Application Number: 17-00798Permit Details
Application Received Date: 12/29/2017
Commercial Addition
Application Approved Date:
Application Approved Status: RESUBMIT2
12/29/2017
2211 W 1000 S
2211 W 1000 S - Burton Elem. Addition
Status of Plan Reviews Completed
02/22/2018Electrical Review COMPLETED
03/09/2018Building Review REVISIONS
03/09/2018Planning and Zoning Review - Site Plan COMPLETED
03/26/2018Fire Department Review - Site Plan COMPLETED
03/27/2018Public Works Review - Site Plan N/A
04/05/2018Plumbing Review COMPLETED
04/05/2018HVAC Review COMPLETED
Permit Review Status
Plan Reviews Still in Progress
Building Review
DESCRIPTION COMMENTS STA TUS
*Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed!
Fire walls meet the requirements of IBC Section
706
REVISIONSSheet A3.11 is missing.
*Revisions Response :
Ducts and dampers meet the requirements of IBC
Section 717
REVISIONSFire dampers are not shown on duct
penetrations at fire wall.
*Revisions Response :
Building complies with IECC (IBC 1301)REVISIONSR-38 in attic does not meet prescriptive
requirements. Provide an energy compliance
report for the addition.
*Revisions Response :
Occupant load is identified on plans as per IBC
Section 1004
Not identified. 140 additional occupant load
allowed unless calculations are otherwise
submitted and approved.
COMPLETED
Penetrations comply with IBC Section 714 for
rated assemblies
Maintain fire rating at all fire wall penetrations.COMPLETED
Reviewed By: Quinton Owens
Review Date: 03/09/2018
Plan Review Details
quinton.owens@rexburg.org
Building Review Status: REVISIONS
Additional Inspector Comments:
Missing sheets A2.21 (Exterior Elevations) and A3.11 (Building Sections)
Page 1 of 2
Approval of plans does not constitue approval of variance from code
Building Review (Continued)
D ESCRIPTIO N CO MMEN TS STATUS
Page 2 of 2
Approval of plans does not constitue approval of variance from code
Review
Report
Current Planning and Zoning Review - Site Plan Status: APPROVED
Application Number: 17-00798Permit Details
Application Received Date: 12/29/2017
Commercial Addition
Application Approved Date:
Application Approved Status: RESUBMIT2
12/29/2017
2211 W 1000 S
2211 W 1000 S - Burton Elem. Addition
Status of Plan Reviews Completed
02/22/2018Electrical Review COMPLETED
03/09/2018Building Review REVISIONS
03/09/2018Planning and Zoning Review - Site Plan COMPLETED
03/26/2018Fire Department Review - Site Plan COMPLETED
03/27/2018Public Works Review - Site Plan N/A
04/05/2018Plumbing Review COMPLETED
04/05/2018HVAC Review COMPLETED
Permit Review Status
Plan Reviews Still in Progress
Building Review
Reviewed By: Quinton Owens
Review Date: 03/09/2018
Plan Review Details
quinton.owens@rexburg.org
Planning and Zoning Review - Site Plan Status: APPROVED
Additional Inspector Comments:
Missing sheets A2.21 (Exterior Elevations) and A3.11 (Building Sections)
Page 1 of 1
Approval of plans does not constitue approval of variance from code