HomeMy WebLinkAboutINSPECTION SUMMARY - 16-00669 -601 Canyon Springs Dr - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 03/21/2018 3:00 pm Permit Details Permit Number: 16-00669 601 Canyon Springs Dr - SFR 601 Canyon Springs Dr Building - Single Family Residence Permit Issued Date: 11/04/2016 Permit Inspection Statistics 25Total Inspections Completed: 18Total Inspections Passed: Inspection Pass Rate: 72.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 11/23/2016PassTed DyeResidential Footing Inspection 11/28/2016PassTed DyeFoundation Inspection 05/05/2017FailTed DyeSheeting Sheeting that missed being nailed to studs have been marked with pink paint.Inspector Comments: 05/10/2017FailTed DyeResidential Framing/Structure Inspection 05/10/2017PassTed DyeSheeting Area's corrected. OK to cover.Inspector Comments: 05/15/2017FailTed DyeResidential Framing/Structure Inspection 05/17/2017PassTed DyeResidential Framing/Structure Inspection 05/24/2017PassTed DyeResidential Insulation Inspection 06/14/2017PassTed DyeResidential Sheetrock/Drywall Inspection Inspected by LarryInspector Comments: 07/05/2017PassLarry BeesleySidewalk Inspection 08/29/2017PassLarry BeesleyResidential Building Final 01/24/2018N/ATed DyeRadon-Ground Inspection Electrical Inspection Type 05/10/2017PassBret StoddardResidential Electrical Rough-in 05/10/2017PassBret StoddardResidential Electrical Service Inspection 08/23/2017PassBret StoddardResidential Electrical Final Inspection Page 1 of 2 (Continued) Permit Details Permit Number: 16-00669 601 Canyon Springs Dr - SFR 601 Canyon Springs Dr Building - Single Family Residence Permit Status of (Open) as of Report Date: 03/21/2018 3:00 pm Permit Inspection Summary Mechanical Inspection Type 05/10/2017FailDon AllenHVAC Rough-in Need 1 inch clearance around the B vent. Need to fix the water lines that are cut out. Gas pressure held at 80 lb Inspector Comments: 05/16/2017PassDon AllenHVAC Rough-in 08/23/2017FailDon AllenHVAC Final Inspection WATER HEATER VENT Needs TO BE HOOKED UP.Inspector Comments: 08/29/2017PassDon AllenHVAC Final Inspection GOOD FOR THE C/OInspector Comments: Plumbing Inspection Type 12/13/2016PassDon AllenPlumbing Underground Inspection Good to cover the plumbing undergroundInspector Comments: 02/15/2017PassDon AllenPlumbing Water Good to cover the water line. Will look at the water meter at the final for final grade. Inspector Comments: 02/15/2017PassDon AllenPlumbing Sewer Good to cover the sewer lineInspector Comments: 05/05/2017PassDon AllenPlumbing Rough-in 08/23/2017FailDon AllenPlumbing Final Inspection TUB AND SHOWER DOWN STAIRS NEEDS FINISH TRIM PUT ON. WATER METER NEEDS TO BE BROUGHT DOWN TO FINAL GRADE OF LOT. WATER HEATER NEEDS TO BE TURNED SO THE CONTROLES ARE FACING TO THE FROUNT. Inspector Comments: 08/29/2017PassDon AllenPlumbing Final Inspection Page 2 of 2