FIRE SPRINKLER INFO - 17-00626 - 1175 W Main St - Valley Wide - Addition & Remodel
The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model DH56 Model DH56 Recessed Model DH56 Concealed Quick Response, Extended Coverage Sprinkler B u l l e t i n 0 1 5 R e v . C Bulletin 015 Rev. C For coverages up to 28 feet wide and 10 feet long(1). 250 psi (17,2 bar) rated. Features: 1. Coverage for long and narrow spaces such as hallways, corridors, decks and rooms up to 28 feet wide and 10 feet long.(1) 2. Deflector to ceiling dimensions are: 4” (102mm) min. to 12” (305mm) max. 3. Minimum spacing between sprinklers 14 feet (4.3m). 4. Polyester Coated or Electroless Nickel PTFE Plated Corrosion Resistant Sprinklers *Concealed Sprinkler is not corrosion resistance 5. UL Listed for extended coverage, light hazard applications. 6. 5.6 K Factor. 7. Sprinkler is approved for 250 psi (17,2 bar) applications. 8. Quick response performance. 9. ½” (13mm) adjustment of escutcheon and cover. 10. Concealed cover plate can prevent the sprinkler from being used for unintended purposes. No ex- posed thermal element with the concealed ver- sion. 11. Push-on/thread-off sturdy convenient escutch- eon for recessed and cover for concealed. 12. Factory assembled sprinkler & cup, shipped complete with protective cap for concealed and FP recessed versions. 13. Sprinkler & cup assembly and escutcheon or cover are separately packaged. 14. Available in a variety of plated and painted finishes. (1) See Figure 4. Approval Organizations 1. Listed by Underwriters Laboratories Inc. and UL certified for Canada (cULus) 2. NYC MEA 258-93-E Patents US Patent No. 7,841,418 Other Patents Pending DH56 FP ReccesedDH56 DH56 F2 Recessed Products Description The Model DH56 family of sprinklers are quick response extended coverage sidewall sprinklers for use in light hazard applications. The Model DH56 with SWC cover plate is a concealed sprinkler that uses Reliable’s push on/ thread off sidewall cover. This sprinkler has the cup fac- tory mounted and is shipped with a protective cap that protects the 3mm frangible glass bulb during shipping and post installation finishing operations. The DH56 can be combined in the field with the FP or F2 Escutcheon to make a recessed sprinkler. The SWC cover plate, FP and F2 recessed escutcheons have ½” adjustment. The SWC cover plate is attached with 135-degree solder. In the event of a fire the rising ambient temperature melts the solder and the cover plate is ejected away by springs exposing the 3mm frangible glass bulb. The use of a 3mm bulb allows quick response which enables the sprinkler to apply water to a fire sooner than standard response sprin- klers of the same temperature rating. Application The Model DH56 is a horizontal sidewall sprinkler intended for installation in light hazard occupancies in accordance with NFPA 13. These sprinklers are designed to provide fire pro- tection in long and narrow spaces such as hallways, corri- dors, decks and rooms up to 28 feet (8,5m) wide and 10 feet (3m) long. They are rated for 250 psi (17,2 bar) and can be mounted between 4 and 12 inches (102 and 305mm) down from the ceiling. DH56 Concealed with SWC coverplate 2. Technical Data (1): K Factor Thread Size Temperature Rating MaximumAmbient Temperature Sprinkler Identifica-tion Number (SIN)US Met-ric Sprinkler SWCCover 56 80 1/2” NPT R1/2 155°F (68°C) 135°F (57°C) 100°F (38°C) RA1564 175°F (79°C) 165°F (74°C) 150°F (66°C) 200°F (93°C) 165°F (74°C) 150°F (66°C) (1) Minimum spacing of 14 feet (4,3m). Coverage Area Maximum Coverage Area Width x Lengthft x ft (m x m) Flow Rate gpm (L/min) Pressure psi (bar) 28 x 8 (8,5 x 2,4)23 (87,1)16.9 (1,2) 28 x 10 (8,5 x 3)28 (106)25 (1,7) Approval Type: • Quick Response, Extended Coverage. • Approved for installation in accordance with NFPA 13 for light hazard occupancies. Maintenance Model DH56 should be inspected and the sprinkler main- tained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Re- move any sprinkler/cover assembly, which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick re- placement of damaged or operated sprinklers. Prior to instal- lation, sprinklers should be maintained in their original cartons and packaging until used to minimize the potential for dam- age to sprinklers that would cause improper operation or non- operation. Installation DH56 Recessed, FP Escutcheon To install the DH56 with the FP Escutcheon as a re- cessed sprinkler cut a 2 5/8” diameter hole in the wall as shown in Figure1. Remove temporarily the plastic protec- tive cap, then use the GFR2 wrench to tighten the sprin- kler until secured in the sprinkler fitting. NOTE: The GFR2 wrench has a notch in it to accommodate the deflector top. This wrench can only be inserted one way. Care must be taken not to damage the deflector during tightening. Apply a PTFE based sealant to the sprinkler threads be- fore installing in the fitting. When inserting or removing the wrench from the sprinkler cup, care must be taken to pre- vent damage to the sprinkler. Wrench only on the square boss. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. It is recommended that the sprinkler be pro- tected during plastering and painting operations by rein- stalling the protective cap P/N 6802710003. Installation is completed by removing the protective cap and inserting the push-on escutcheon. Turn clockwise to adjust the es- cutcheon against the wall. DH56 Recessed, F2 Escutcheon To install the DH56 with the F2 Escutcheon as a re- cessed sprinkler cut a 2 ¼” diameter hole in the wall as shown in Figure 2. Thread the DH80 into the collar hand tight. Apply a PTFE based sealant to the sprinkler threads and install in the fitting. Wrench only on the square boss. NOTE: The GFR2 wrench has a notch in it to accommo- date the deflector top. This wrench can only be inserted one way. When inserting or removing the wrench from the sprinkler cup care must be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. It is recommended that the sprinkler be protected during plastering and painting operations by using the protective cap P/N 6999991009. These must be ordered separately. Installation is completed by removing the protective cap and inserting the F2 Escutcheon over the collar. DH56 with SWC Cover Plate Concealed To install the sprinkler, cut a 2 5/8” diameter hole into the wall as shown in Figure1. A PTFE based thread sealant should be applied to the sprinkler threads only. Remove the protective cap (P/N 6802710003) and then position the GFR2 wrench into the sprinkler/cup assembly until the wrench engages the flats of the square boss. Then tighten the sprinkler into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprin- kler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The protective caps should be reinstalled for protection during plastering and painting. Remove caps only when covers are being installed. The cover assembly is then pushed onto the cup. Cover assemblies provide ½” (13mm) of adjustment. Final adjustment is made by turning the cover clockwise until the skirt flange makes full contact with the wall surface. Cover removal requires turning in the counter- clockwise direction. Concealed cover/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover/cup assembly with the Model DH56 Horizontal Side- wall Sprinkler or the use of the concealed cover assembly on any sprinkler with which it is not specifically listed will void all guarantees, warranties, listings and approvals. Note: DH56 and DH56 Recessed Sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling, and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protec- tors before this time may leave the bulb vulnerable to dam- age. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. 3. Model DH56 Quick Response Extended Coverage Horizontal Sidewall Sprinkler Specification Sprinklers shall be a [quick response – cULus Listed] ex- tended coverage horizontal sidewall sprinkler for light hazard occupancies. Sprinklers to be of bronze frame construction with a special deflector capable of providing a discharge over a coverage area of 28 ft. (8,5m) wide, and 10 ft. (3m) long horizontal throw. Water seal assembly shall consist of a PTFE coated Belleville spring washer and machined brass cup with 3 mm glass bulb containing no plastic parts. Installation shall permit sprinkler deflectors to be positioned 4” (102mm) to 12” (305mm) below the ceiling. Sprinklers shall have a nominal K- factor of 5.6 (80), and 1/2” NPT thread. Sprinkler temperature rating shall be [155°F (68° C)][200°F (93°C)]. Rated working pressure shall be 250 psi (17.2 bar). Standard finish: [white] [chrome][bronze][Special finish– specify]. Quick response horizontal sidewall sprinklers shall be Reliable Model DH56, SIN RA1564 (Bulletin 015). For recessed horizontal sidewall sprinklers: Replace “hori- zontal sidewall” with “recessed horizontal sidewall.” Add: (1) Recessed escutcheon assembly shall be a two-piece es- cutcheon of push-on and thread off design with ½” (13mm) adjustment. Standard finish shall be [chrome] [white]; or (2) Recessed escutcheon assembly shall be a two-piece “friction fit” escutcheon with ½” adjustment. Standard finish: [white] [chrome][bright brass][Special finish– specify]. Quick re- sponse recessed horizontal sidewall sprinklers shall be Reli- able Model DH56, SIN RA1564 (Bulletin 015). For concealed horizontal sidewall sprinklers: Replace “horizontal sidewall” with “concealed horizontal sidewall.” Add: Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” (13mm) cover plate adjust- ment. Cover plate temperature rating shall be 135°F (57°C) for 155°F (68°C) sprinkler and 165°F (74°C) for 200°F (93°C) sprinkler. A plastic protective cap shall be provided and fac- tory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [white] [Custom Color– specify]. Quick response concealed hori- zontal sidewall sprinklers shall be Reliable Model DH56, SIN RA1564 (Bulletin 015). UL Listing Category Sprinklers, Automatic and Open. Quick Response Sprinklers. Installation Wrench Model GFR2 Sprinkler Wrench Note: A leak tight ½” NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10.8-24.4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprin- klers. Installation Aid For concealed, a protec- tive plastic cap is included for use during installation. Escutcheon Data: FP cup/escutcheon assembly - 1/2” (13mm) adjustment F2 - 1/2” (13mm) adjust- ment Ordering Information Specify: • DH56 - Sprinkler Finish • DH56 Recessed -Sprinkler Finish • FP or F2 Escutcheon -Escutcheon Finish • SWC Concealed -Cover-Plate Finish • Protective cap for use with F2 escutcheons Finishes (1) Standard Finishes (1) Sprinkler FP Escutcheon F2 Escutcheon Cover PlateWhite or Black Polyester (2) Chrome Bronze White Chrome White ChromeBright Brass White Special Application FinishesSprinklerF2/ FP EscutcheonsElectroless Nickel PTFE(2) Electroless Nickel PTFE (1) Other colors and finishes are available. Consult factory for details. (2) cULus listed Corrosion Resistant. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. Figure 1. Figure 4. The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 01/18 P/N 9999970307 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.Products manufactured and distributed by Reliable have been protecting life and property for over 90 years. Figure 2. Figure 3. Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard Worldwide Contacts www.tyco-fire.com Page 1 of 8 NOVEMBER 2014 TFP220 IMPORTANTAlways refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal-lation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo-nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. General Description TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers are decorative glass-bulb sprinklers designed for use in light or ordinary hazard occu-pancies. They are intended for use in automatic sprinkler systems designed in accordance with standard installa-tion rules (e.g., NFPA 13) for a maximum coverage area of 400 ft2 (37,2 m2), as compared to the maximum coverage area of 130 ft2 (12,1 m2) for standard coverage sprinklers used in ordinary hazard occupancies or 225 ft2 (20,6 m2) for standard coverage sprinklers used in light hazard occupancies. Series EC-11 and EC-14 Sprinklers feature a UL and C-UL Listing that permits their use with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13, as well as a specific appli-cation listing for use under concrete tees. Series EC-11 and EC-14 Extended Coverage Sprinklers have been fire tested to compare their performance to that of standard coverage spray sprin-klers. These tests have shown that the protection provided is equal to or more effective than standard coverage spray sprinklers. Corrosion-resistant coatings, where applicable, help extend the life of copper alloy sprinklers beyond that which occurs when exposed to corrosive atmospheres. Although corro-sion-resistant coated sprinklers passed standard corrosion tests of the appli-cable approval agencies, this testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion-resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity should be consid-ered, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTICE Series EC-11 and EC-14 Extended Coverage Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main-taining their fire protection system and devices in proper operating condition. Contact the installing contractor or product manufacturer with any questions. Sprinkler Identification Numbers (SINs) TY5137 - Upright, 11.2K TY5237 - Pendent, 11.2K TY6137 - Upright, 14.0K TY6237 - Pendent, 14.0K TY5137 is a re-designation for C5137, G1894, and S2510. TY5237 is a re-designation for C5237, G1893, and S2511. TY6137 is a re-designation for C6137, G1896, and S2610. TY6237 is a re-designation for C6237, G1895, and S2611. TFP220 Page 2 of 8 Technical Data ApprovalsTYCO Series EC-11 and EC-14 Extended Coverage Upright, Pendent, and Recessed Pendent Sprinklers are UL and C-UL Listed. Refer to Table A for complete sprinkler approval infor-mation including corrosion-resistant status. The approvals apply to the service conditions indicated in the Design Criteria section. Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers are FM Approved. Refer to Table A for complete sprinkler approval information including corrosion-resis-tant status. The approvals apply to the service conditions indicated in the Design Criteria section. The Style 60 Two-Piece Flush Escutcheon (Figure 4) is UL Listed and FM Approved for use with the Series EC-11 and EC-14 Pendent Sprinklers. Maximum Working Pressure175 psi (12,1 bar) Pipe Thread Connection3/4 inch NPT Discharge CoefficientsK = 11.2 gpm/psi1/2 (161,3 lpm/bar1/2) K = 14.0 gpm/psi1/2 (201,6 lpm/bar1/2) Temperature RatingsRefer to Table A. FinishSprinkler: Refer to Table A. Recessed or Flush Escutcheon: White-Coated, Chrome-Plated, and Brass-Plated Physical CharacteristicsFrame.......................BronzeButton.......................BronzeSealing Assembly.......Beryllium Nickel w/TEFLONBulb ...................Glass (3 mm)Compression Screw. . . . . . . . . . . . BronzeDeflector......................Brass Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprinkler to activate and flow water. Design Criteria TYCO Series EC-11 and EC-14 Extended Coverage Sprinklers must only be installed in accordance with the applicable UL and C-UL Listing or FM Approval requirements as indicated below. Only Style 30 or 40 Recessed Escutcheons are to be used for recessed installation, as applicable. Refer to Tables A, B, and C. SECTION CROSS PENDENTUPRIGHT 1 2 3 4 5 6 WRENCHFLAT ESCUTCHEON PLATESEATING SURFACE 1/2" (12,7 mm)NOMINAL MAKE-IN 1-11/16"(42,7 mm) 2-7/16"(61,9 mm)UPRIGHT &PENDENT * **3/4"NPT Pipe thread connections perISO 7-1 can be provided onspecial request. 5 4 6 Components: 23 Temperature rating isindicated on Deector. - Compression Screw-Bulb -Deector --Sealing AssemblyButton Frame1- ** * * FIGURE 1 SERIES EC-11 AND EC-14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR UPRIGHT (TY5137) AND PENDENT (TY5237) 14.0 K-FACTOR UPRIGHT (TY6137) AND PENDENT (TY6237) ASSEMBLY TFP220 Page 3 of 8 Hazard Type Temperature Bulb Liquid Sprinkler Finish (See Note 5) Natural Brass Chrome Plated Polyester*Lead Coated Light Table B describes UL and C-UL Sensitivity Rating Table C describes FM Sensitivity Rating Upright K=11.2 (TY5137) Pendent K=11.2 (TY5237) K=14.0 (TY6237) 135°F (57°C)Orange 1, 2, 3**, 4155°F (68°C)Red 175°F (79°C)Yellow 1, 2, 4 1, 2, 4200°F (93°C)Green 286°F (141°C)Blue Recessed Pendent K=11.2 (TY5237) K=14.0 (TY6237) With Style 30 Escutcheon 135°F (57°C)Orange 1, 2, 3, 4 N/A 155°F (68°C)Red 175°F (79°C)Yellow 1, 2, 4200°F (93°C)Green 286°F (141°C)Blue Ordinary Table B describes UL and C-UL Sensitivity Rating Table C describes FM Sensitivity Rating Upright K=11.2 (TY5137) K=14.0 (TY6137) Pendent K=11.2 (TY5237) K=14.0 (TY6237) 135°F (57°C)Orange 1, 2, 3, 4 1, 2, 3, 4155°F (68°C)Red 175°F (79°C)Yellow 1, 2, 4200°F (93°C)Green 286°F (141°C)Blue Recessed Pendent K=11.2 (TY5237) K=14.0 (TY6237) With Style 30 or 40 Escutcheon 135°F (57°C)Orange 1, 2, 4 N/A155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green Notes (1). Listed by Underwriters Laboratories, Inc. (UL) (2). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) (3). Approved by Factory Mutual Research Corporation (FM) (4). Approved by the City of New York under MEA 177-03-E (5). Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Cor-rosion Resistant Sprinklers * Frame and Deflector only. ** Pendent Only N/A: Not Available Area Style Light Hazard Ordinary Hazard 135°F (57°C)155°F (68°C)175°F (79°C)200°F (93°C)286°F (141°C)135°F (57°C)155°F (68°C)175°F (79°C)200°F (93°C)286°F (141°C) 14 x 14 Upright or Pendent -----QR QR QR QR QR Style 30 Recessed -----QR QR QR QR QR Style 40 Recessed -----QR QR QR QR QR 16 x 16 Upright or Pendent QR*QR*QR*QR*QR*SR SR SR SR SR Style 30 Recessed QR*QR*QR*QR*QR*SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR 18 x 18 Upright or Pendent QR*QR*QR*QR*QR*SR SR SR SR SR Style 30 Recessed QR*QR*QR*QR*QR*SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR 20 x 20 Upright or Pendent QR*QR*QR*SR*SR*SR SR SR SR SR Style 30 Recessed QR*QR*QR*SR*SR*SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR QR: Quick Response SR: Standard Response N/A: Not Applicable * Does not apply to Upright K=14.0 TABLE A LABORATORY LISTINGS AND APPROVALS TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-11 OR EC-14 SPRINKLERS (Refer to Table D for Permitted K-Factor/Area Combinations) TFP220 Page 4 of 8 UL and C-UL Listing Requirements1. Series EC-11 and EC-14 Sprinklers may be used for the coverage areas shown in Table D, based on main-taining the minimum specified flow rate as a function of coverage area and hazard group for all sprinklers in the design area. 2. Series EC-11 and EC-14 Sprinklers are permitted to be used with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13; for example: • Unobstructed, combustible or noncombustible, ceiling construc-tion with a deflector to ceiling/roof deck distance of 1 to 12 inches (25 to 300 mm). • Obstructed, non-combustible, ceiling construction with a deflector location below struc-tural members of 1 to 6 inches (25 to 150 mm) and a maximum deflector to ceiling/roof deck distance of 22 inches (550 mm). 3. Series EC-11 and EC-14 Sprinklers, specifically tested and listed for non-combustible obstructed construction, are permitted to be used within trusses or bar joists having non-combustible web members greater than 1 inch (25.4 mm) when applying the 4 times obstruction criteria rule defined under “Obstructions to Sprinkler Discharge Pattern Development”. 4. To prevent cold soldering, the minimum allowable spacing between Series EC-11 and EC-14 Sprinklers, is 8 feet (2,4 m) for upright sprinklers and 9 feet (2,7 m) for pendent sprinklers. HC-1 Linear Spacing Area Spacing Ceiling Height Ceiling Type K-factor Style ResponseMinMaxMinMax 10 20 100 400 Up to 30 Noncombustible Unobstructed, Noncombustible Obstructed, or Combustible Unobstructed 11.2 EC 14.0 EC Pendent or Upright Quick 10 20 100 400 Up to 30 Noncombustible Unobstructed, Noncombustible Obstructed, or Combustible Unobstructed 11.2 EC 14.0 EC Pendent Recessed Style 30 10 20 100 400 Up to 30 Combustible obstructed 11.2 EC 14.0 EC Pendent or Upright 10 20 100 400 Up to 30 Combustible obstructed 11.2 EC 14.0 EC Pendent Recessed Style 30 10 20 100 400 Over 30 and up to 45 Noncombustible Unobstructed 11.2 EC 14.0 EC Upright HC-2 Linear Spacing Area Spacing Ceiling Height Ceiling Type K-factor Style ResponseMinMaxMinMax 10 20 100 400 Up to 30 Noncombustible Unobstructed, Combustible Unobstructed 11.2 EC Upright Quick1020100400Up to 30 14.0 EC Pendent or Upright 10 16 100 256 Over 30 and up to 45 11.2 EC 14.0 EC Upright HC-3 Linear Spacing Area Spacing Ceiling Height Ceiling Type K-Factor Style ResponseMin Max Min Max 10 16 100 256 Up to 30 Noncombustible Unobstructed, Combustible Unobstructed 11.2 EC Upright Quick1020100400Up to 30 14.0 EC Pendent or Upright 10 16 100 256 Over 30 and up to 45 11.2 EC, 14.0 EC Upright NOTE1. The design for K 11.2 EC (K 160 EC) sprinklers should not include fewer than six sprinklers or have a design pressure of less than 12 psi (0,8 bar); similarly the design for K 14.0 EC (K 200 EC)sprinklers should not include fewer than four sprinklers or have a design pressure of less than 18 psi (1,2 bar). 2. For flow criteria, refer to FM Loss Prevention Data Sheet 3-26. TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-11 OR EC-14 SPRINKLERS(Note: Refer to FM Loss Prevention Data Sheet 2-0 for permitted K-factor/area combinations) TFP220 Page 5 of 8 5. Series EC-11 and EC-14 Sprinklers are to be installed in accordance with all other requirements of NFPA 13 for extended coverage upright and pendent sprinklers; For example, obstructions to sprinkler discharge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard and clearance to storage. UL and C-UL Specific Application Listing Requirements for Installation under Concrete TeesSeries EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers (TY5137, TY5237, TY6137 and TY6237) have a UL and C-UL Specific Application Listing for use under concrete tees when installed as follows: 1. Stems of the concrete tee construc-tion must spaced at less than 7.5 feet (2,3 m) on center but more than 3 feet (0,9 m) on center. The depth of the concrete tees must not exceed 30 inches (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m). However, where the concrete tee length exceeds 32 feet (9,8 m), non-combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 feet (9,8 m) in length. 2. The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25,4 mm) below the bottom of the concrete tee stems. 3. When the sprinkler deflectors are located higher than a horizontal plane 1 inch (25,4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler discharge criteria requirements of NFPA 13 for extended coverage upright and pendent sprinklers applies. FM Approval RequirementsSeries EC-11 and EC-14 Extended Coverage Sprinklers are to be installed in accordance with the applicable Factory Mutual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non-storage and/or non-flam-mable or combustible liquid) occu-pancies. Information provided in the FM Loss Prevention Data Sheets relates to, but not limited to, hydraulic design, ceiling slope, and obstructions, minimum and maximum allowable spacing, and deflector-to-ceiling distance. These criteria may differ from UL and/or NFPA criteria. Therefore, the designer should review and become familiar with Factory Mutual requirements before proceeding with design. Description Area Light Hazard 0.10 gpm/ft2 Group I Ordinary Hazard 0.15 gpm/ft2 Group II Ordinary Hazard 0.20 gpm/ft2 gpm psi gpm psi gpm psi TY5137 (K=11.2) Upright 14 x 14 30 7.2 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 18 x 18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 TY5237 (K=11.2) Pendent 14 x 14 30 7.2 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 18 x 18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 TY6137 (K=14.0) Upright 14 x 14 N/A N/A 39 7.8 51 13.3 16 x 16 N/A N/A 39 7.8 51 13.3 18 x 18 N/A N/A 49 12.3 65 21.6 20 x 20 N/A N/A 60 18.4 80 32.7 TY6237 (K=14.0) Pendent 14 x 14 37 7.0 39 7.8 51 13.3 16 x 16 37 7.0 39 7.8 51 13.3 18 x 18 37 7.0 49 12.3 65 21.6 20 x 20 40 8.2 60 18.4 80 32.7 1 ft. = 0.3048 m 1 ft.2 =0.093 m2 1 gpm = 3.785 lpm 1 psi = 0.06895 bar 1 gpm/ft2 = 40.74 mm/min TABLE D FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-11 AND EC-14 SPRINKLERS TFP220 Page 6 of 8 Installation Series EC-11 and EC-14 Sprinklers must be installed in accordance with this section. General InstructionsDo not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 3/4 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler with the deflector parallel to the mounting surface. Install pendent sprinklers in the pendent position; install upright sprin-klers in the upright position. Step 2. After installing the Style 30, 40, or 60 mounting plate (or other applicable escutcheon) over the sprinkler pipe threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 3. For upright or pendent sprin-klers wrench-tighten using only the MOUNTING SURFACE FACE OF SPRINKLER FITTING 2-1/4" DIA. (57,2 mm) 2-7/8" DIA.(73,0 mm) MOUNTING PLATE 1/8"(3,2 mm) 5/8±1/4" (15,9±6,4 mm) 7/8" (22,2 mm) 1-3/8" (34,9 mm) 1/4" (6,4 mm) 3/4" (19,1 mm) CLOSURE MOUNTINGSURFACE1/8"(3,2 mm) 1-13/16" (46,0 mm) 2-5/16" (58,7 mm)CLOSURE ESCUTCHEON PLATESEATING SURFACE:1/4" (6,4 mm) ABOVETO 1/2" (12,7 mm) BELOWMOUNTING SURFACE;3/4" (19,1 mm) TOTALADJUSTMENT 2-1/4" DIA.(57,2 mm) 2-7/8" DIA.(73,0 mm) FACE OFSPRINKLER FITTING:3/8" (9,5 mm) ABOVETO 1/8" (3,2 mm) BELOWMOUNTING SURFACE 3/4" NPT MOUNTING PLATE INTERNAL DIMENSIONS OF STYLE 60 ESCUTCHEON ACCOMMODATE CLASS 150 MALLEABLE IRON REDUCING SPRINKLER FITTING "FITTING SIDE"TOWARDS SPRINKLERFITTING WRENCH RECESS (END "A") WRENCH RECESS WRENCH HEX 1/4" (6,4 mm) 1/2" (12,7 mm) MOUNTING SURFACE FACE OF SPRINKLER FITTING 1/2±1/8" (12,7±3,2 mm)2-1/4" DIA. (57,2 mm) 2-7/8" DIA.(73,0 mm) CLOSURE 1-3/8" (34,9 mm) 1-1/8" (28,6 mm) MOUNTINGPLATE 1/8"(3,2 mm) FIGURE 3 SERIES EC-11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON FIGURE 4 SERIES EC-11 AND EC-14 PENDENT SPRINKLER ASSEMBLY WITH 3/4 INCH TOTAL ADJUSTMENT STYLE 60 TWO-PIECE FLUSH ESCUTCHEON FIGURE 5 W-TYPE 3 SPRINKLER WRENCH FIGURE 6 W-TYPE 22 RECESSED SPRINKLER WRENCH FIGURE 2 SERIES EC-11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON TFP220 Page 7 of 8 P/N 51 – XXX – X – XXX * Escutcheon ordered separately ** OPEN indicates sprinkler assembly without glass bulb, button, and sealing assembly. W-Type 3 (End A) Sprinkler Wrench. For the pendent sprinkler installed with Style 30, 40, or 60 Escutcheon, wrench-tighten the sprinkler using only the W-Type 22 Sprinkler Wrench. Apply the wrench recess of the appli-cable sprinkler wrench (Figure 5 and 6) to the sprinkler wrench flats (Figure 1). Care and Maintenance TYCO Series EC-11 and EC-14 Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Frequent visual inspections are recom-mended to be initially performed for corrosion resistant coated sprin-klers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards recognized by the Approval agency (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems are recom-mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread ConnectionsSpecify: Series EC-11 or EC-14 (specify) Sprinkler, SIN (specify), (specify) K-factor, Pendent or Upright (specify) Extended Coverage, (specify) temper-ature rating, (specify) finish, P/N (from to Table E) Recessed Escutcheon, Two-PieceSpecify: Style (30 or 40) Two-Piece Recessed Escutcheon with (specify) finish, P/N (specify*) Flush Escutcheon, Two-PieceSpecify: Style 60 Two-Piece Flush Escutcheon with (specify) finish, P/N (specify*) *Refer to Technical Data Sheet TFP778 Sprinkler WrenchesSpecify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Specify: W-Type 22 Recessed Sprinkler Wrench, P/N 56-665-7-001 SIN 893 11.2K PENDENT TY5237 894 11.2K UPRIGHT TY5137 895 14.0K PENDENT TY6237 896 14.0K UPRIGHT TY6137 SPRINKLER FINISH* 1 NATURAL BRASS 4 SIGNAL WHITE (RAL9003) POLYESTER 5 JET BLACK (RAL9005) POLYESTER 7 LEAD COATED 9 CHROME-PLATED TEMPERATURE RATING 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) 000 OPEN** TABLE E SERIES EC-11 AND EC-14 UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP220 Page 8 of 8 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. APR 2017 GFS-505a (Formerly A-55) EXTENDED QUICK RESPONSEAUTOMATIC SPRINKLERSGL SERIESDRY TYPE PENDENT DESCRIPTION AND OPERATION RECESSED SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING • Water Working Pressure Rating - 175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) • Maximum low temperature glass bulb rating is -67°F (-55°C) • Frame - bronze • Defl ector - brass • Screw - brass • Bulb Seat - brass • Spring - nickel alloy • Seal - tefl on • Retainer - brass • Pin - stainless steel • Torsion Spring - stainless steel • Orifi ce Insert - brass • Bulb - glass with alcohol based solution, 3mm size • 3/4”NPT or 1”NPT • Outer Tube - galvanized steel pipe • Inner Tube - stainless steel TECHNICAL DATA • See reverse side for Approvals and Specifi cations. • Temperature Ratings -135°F (57°C), 155°F (68°C), 175°F (79°C) 200°F (93°C), 286°F (141°C) The Globe Quick Response GL Series Dry Type Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. The Globe Quick Response GL Series Dry Type Pendent Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water fl ows through the sprinkler and is distributed by the defl ector in an approved discharge pattern. It can be installed wherever standard spray sprinklers are specifi ed but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's Model GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fl uid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. SLEEVE & SKIRTSURFACEMOUNT CLASSIFICATION AVAILABLE SPRINKLER TEMPERATURES BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURE ORDINARY INTERMEDIATE HIGH 135°F/155°F 175°F/200°F 286°F 57°C/68°C 79°C/93°C 141°C ORANGE/RED YELLOW/GREEN BLUE 100°F 150°F 225°F 38°C 66°C 107°C APR 2017 GFS-505a (Formerly A-55) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 1FINISHES AVAILABLE ON SPECIAL ORDER. 2cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. SPECIFICATIONS APPROVALS PRINTED U.S.A. 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 FAX 989-846-9231 www.globesprinkler.com 989-846-4583 1-800-248-0278 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specifi c details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). QUICK RESPONSEAUTOMATIC SPRINKLERSGL SERIES DRY TYPEPENDENT 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. *PENDENT STYLE - FM APPROVED 155°F (68°C), 200°F (93°C), AND 286°F (141°C) *RECESSED PENDENT STYLE - FM APPROVED 155°F (68°C) AND 200°F (93°C) LH: LIGHT HAZARD; OH: ORDINARY HAZARD NOMINAL “K” FACTOR THREAD SIZE LENGTH FINISHES 5.6 (80 metric) 3/4” or 1”NPT cULus Variable to 48” FM Variable to 36” Factory Bronze Chrome White Polyester2 Black Polyester1,28.0 (115 metric) 1”NPT STYLE SIN MODEL K FACTOR THREAD SIZE HAZARD1 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C)*FM cULus NYC-DOB MEA 101-92-E PENDENT RECESSED PENDENT GL5635 5.6 1”NPT LH/OH X X X X X X X X GL5636 5.6 3/4”NPT LH/OH X X X X X --- X X GL8135 8.0 1”NPT LH/OH X X X X X --- X X "A"1" MIN. 3/4"NPT3/4" MIN. 1"NPT 2 1/2" MIN. DIA.HOLE IN CEILING 3 1/2" DIA.FACE OFCEILING FACE OFTEEFITTING 3 3/4" MIN.4 3/4" MAX. TEE FITTINGANSI B16.3 CLASS 155 ORANSI B16.4 CLASS 125 "A"2 1/2" MIN. 3/4"NPT2 1/4" MIN. 1"NPT TEE FITTINGANSI B16.3 CLASS 155 ORANSI B16.4 CLASS 125 FACE OFTEEFITTING FACE OFCEILING 2" TWO PIECEESCUTCHEON 1/4" 3" DIA. 1 1/2" MIN. DIA.HOLE IN CEILING TEE FITTINGANSI B16.3 CLASS 155 ORANSI B16.4 CLASS 125 TEE FITTINGANSI B16.3 CLASS 155 ORANSI B16.4 CLASS 125 "A"3 1/4" MIN. 3/4"NPT2 3/4" MIN. 1"NPT 1/8" 2 15/16" DIA. 2" MIN. DIA.HOLE IN CEILING ESCUTCHEON FACE OFCEILING FACE OFTEEFITTING 1 1/4" MIN.2" MAX.CUP 3 7/32" DIA. 1 3/4" MIN. DIA.HOLE IN CEILING "A"1 3/4" MIN. 3/4"NPT1 1/2" MIN. 1"NPT 2 1/2" MIN.4" MAX. FACE OFCEILING FACE OFTEEFITTING TWO PIECEESCUTCHEON RETAINER CROSS SECTIONS EXTENDED SLEEVE & SKIRTRECESSED SURFACE MOUNT IMPORTANT INSTALLATION DATA Globe GL Series Dry Pendent Sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18”. Excessive force may distort the frame thus destroying the unit. When installed in a wet system extending into a freezing area see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs. Please refer to our Dry Caution Sheet for further important installation data. ORDERING INFORMATION • Quantity • Model Number • Style • Orifi ce • Temperature • Finishes • Quantity - Wrenches - P/N 333010 • Quantity Recessed Wrenches - P/N 337014 • Escutcheons Desired • Quantity - Protective Caps - P/N 327109-cap (Friction Fit Recessed) “A” Dimension - Distance from face of fi tting to the fi nished ceiling line regardless of escutcheon used. SPECIFY www.reliablesprinkler.com Models DD56-6, DD56-27, DD80-6, DD80-27, DS56, & GP56 Attic Sprinklers Specific Application Sprinklers cULus Listed for Sloped Combustible and Noncombustible Light Hazard Concealed Spaces Product Features DD80 Series sprinklers provide coverage for spans up to 70 ft (21 m) with one row of sprinklers DD56 Series sprinklers provide coverage for spans up to 40 ft (12 m) with one row of sprinklers. Model DS56 sprinkler provides coverage up to 6 ft x 40 ft (1.8 m x 12 m) Model GP56 sprinkler provides coverage up to 10 ft x 15 ft (3.0 m x 4.6 m) All models use a 212°F (100°C) temperature rated fusible-link operating element Product Description Reliable Attic Sprinklers are cULus Listed Specific Appli- cation sprinklers. The sprinklers are available for protection of combustible and non-combustible light hazard con- cealed spaces with roof/ceiling slopes of 4:12 to 8:12. Re- liable Attic Sprinklers are upright sprinklers listed for use on wet-pipe or dry-pipe sprinkler systems. All Reliable Attic sprinklers use a 212°F (100°C) temperature rated fusible-link operating element that is Listed for installation where the maximum ceiling temperature is up to 150°F (66°C). Table A provides a summary of available Reliable Attic sprinklers. Attic Sprinklers Model DD56 Model DD80 Model DS56 Model GP56 Attic Sprinkler Summary Table A Sprinkler Model Nominal K-Factor gpm/psi1/2 (L/min/bar1/2) Thread Size NPT or ISO7-1 Max. Coverage Area (Measured on Floor) ft x ft (m x m) Roof Slope Design Criteria Sprinkler Identification Number (SIN) DD56-6 5.6 (80) ½ 6 x 40 (1.8 x 12) 4:12 to <6:12 Table B RA5624 DD56-27 5.6 (80) ½ 6 x 40 (1.8 x 12) 6:12 to 8:12 Table C RA5694 DD80-6 8.0 (115) ¾ 6 x 66 or 5 x 70 (1.8 x 20 or 1.5 x 21) 4:12 to <6:12 Table D RA5622 DD80-27 8.0 (115) ¾ 6 x 66 or 5 x 70 (1.8 x 20 or 1.5 x 21) 6:12 to 8:12 Table E RA5692 DS56 5.6 (80) ½ 6 x 40 (1.8 x 12) 4:12 to 8:12 Table F RA5625 GP56 5.6 (80) ½ 10 x 15 (3.0 x 4.6) 4:12 to 8:12 Table G RA5695 Bulletin 056 December 2016 Bulletin 056 Page 2 of 24 December 2016 www.reliablesprinkler.com Model DD56-6 Specific Application Sprinkler SIN RA5624 Technical Specifications Style: Upright Orientation: Deflector horizontal Threads: 1/2” NPT or ISO 7-1R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Sprinkler Temperature Rating: 212°F (100°C) Sensitivity: Quick-response Hydraulic Design Criteria (See Table H) Finish Brass Sprinkler Wrench Model R2 or W2 Listings and Approvals cULus Listed Hazard Classification Light Hazard System Types Wet-pipe with steel or Listed CPVC pipe Dry-pipe with steel pipe Installation Criteria Sprinkler Spacing Max: 6 ft (1.8 m) across roof slope Min: 4 ft (1.2 m) across roof slope Min: 26 ft (7.9 m) down the roof slope measured parallel to the roof deck Horizontal Distance from Face of Truss Min: 6 inches (150 mm) Vertical Distance of Deflector Above Scis- sor Truss Min: 18 inches (450 mm) Horizontal Distance from Centerline of Ridge Max: 6 inches (150 mm) Vertical Distance of Top of Deflector Below Peak, Ridge, or Deck Min: 17 inches (430 mm) Max: 21 inches (530 mm) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Levers: Stainless Steel Sprinkler Frame: Brass Alloy Button: Copper Alloy Button Clip: Stainless Steel Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Model DD56-6 Sprinkler Components and Dimensions Figure 1 Model DD56-6 Minimum Required Flow and Residual Pressure Table B Ceiling Slope Max. Coverage Area ft x ft (m x m) Flow gpm (l/min) Pressure psi (bar) 4:12 to less than 6:12 6 x 40* (1.8 x 12) 25 (95) 19.9 (1.37) * Coverage is 20 ft (6.1 m) down slope in two directions measured along the floor. Bulletin 056 Page 3 of 24 December 2016 www.reliablesprinkler.com Model DD56-27 Specific Application Sprinkler SIN RA5694 Technical Specifications Style: Upright Orientation: Deflector horizontal Threads: 1/2” NPT or ISO 7-1R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Sprinkler Temperature Rating: 212°F (100°C) Sensitivity: Quick-response Hydraulic Design Criteria (See Table H) Finish Brass Sprinkler Wrench Model R2 or W2 Listings and Approvals cULus Listed Hazard Classification Light Hazard System Types Wet-pipe with steel or Listed CPVC pipe Dry-pipe with steel pipe Installation Criteria Sprinkler Spacing Max: 6 ft (1.8 m) across roof slope Min: 4 ft (1.2 m) across roof slope Min: 26 ft (7.9 m) down the roof slope measured parallel to the roof deck Horizontal Distance from Face of Truss Min: 6 inches (150 mm) Vertical Distance of Deflector Above Scis- sor Truss Min: 18 inches (450 mm) Horizontal Distance from Centerline of Ridge Max: 6 inches (150 mm) Vertical Distance of Deflector Below Peak, Ridge, or Deck Min: 17 inches (430 mm) Max: 21 inches (530 mm) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Levers: Stainless Steel Sprinkler Frame: Brass Alloy Button: Copper Alloy Button Clip: Stainless Steel Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Model DD56-27 Sprinkler Components and Dimensions Figure 2 Model DD56-27 Minimum Required Flow and Residual Pressure Table C Ceiling Slope Max. Coverage Area ft x ft (m x m) Flow gpm (l/min) Pressure psi (bar) 6:12 to 8:12 6 x 40* (1.8 x 12) 25 (95) 19.9 (1.37) * Coverage is 20 ft (6.1 m) down slope in two directions measured along the floor. Bulletin 056 Page 4 of 24 December 2016 www.reliablesprinkler.com Model DD80-6 Specific Application Sprinkler SIN RA5622 Technical Specifications Style: Upright Orientation: Deflector horizontal Threads: 3/4” NPT or ISO 7-1R3/4 Nominal K-Factor: 8.0 (115 metric) Max. Working Pressure: 175 psi (12 bar) Sprinkler Temperature Rating: 212°F (100°C) Sensitivity: Quick-response Hydraulic Design Criteria (See Table H) Finish Brass Sprinkler Wrench Model R2 or W2 Listings and Approvals cULus Listed Hazard Classification Light Hazard System Types Wet-pipe with steel or Listed CPVC pipe Dry-pipe with steel pipe Installation Criteria Sprinkler Spacing Max: 6 ft (1.8 m) across roof slope Min: 4 ft (1.2 m) across roof slope Min: 26 ft (7.9 m) down the roof slope measured parallel to the roof deck Horizontal Distance from Face of Truss Min: 6 inches (150 mm) Vertical Distance of Deflector Above Scis- sor Truss Min: 18 inches (450 mm) Horizontal Distance from Centerline of Ridge Max: 6 inches (150 mm) Vertical Distance of Deflector Below Peak, Ridge, or Deck Min: 17 inches (430 mm) Max: 21 inches (530 mm) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Levers: Stainless Steel Sprinkler Frame: Brass Alloy Button: Copper Alloy Button Clip: Stainless Steel Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Model DD80-6 Sprinkler Components and Dimensions Figure 3 Model DD80-6 Minimum Required Flow and Residual Pressure Table D Ceiling Slope Max. Coverage Area ft x ft (m x m) Flow gpm (l/min) Pressure psi (bar) 4:12 to less than 6:12 6 x 401 (1.8 x 12) 25 (95) 9.8 (0.68) 6 x 632 (1.8 x 19) 38 (144) 22.6 (1.56) 6 x 663 (1.8 x 20) 40 (151) 25 (1.72) 5 x 704 (1.5 x 21) 38 (144) 22.6 (1.56) 1 Coverage is 20 ft (6.1 m) down slope in two directions measured along the floor. 2 Coverage is 31.5 ft (9.6 m) down slope in two directions measured along the floor. 3 Coverage is 33 ft (10.0 m) down slope in two directions measured along the floor. 4 Coverage is 35 ft (10.7 m) down slope in two directions measured along the floor. Bulletin 056 Page 5 of 24 December 2016 www.reliablesprinkler.com Model DD80-27 Specific Application Sprinkler SIN RA5692 Technical Specifications Style: Upright Orientation: Deflector horizontal Threads: 3/4” NPT or ISO 7-1R3/4 Nominal K-Factor: 8.0 (115 metric) Max. Working Pressure: 175 psi (12 bar) Sprinkler Temperature Rating: 212°F (100°C) Sensitivity: Quick-response Hydraulic Design Criteria (See Tables E and H) Finish Brass Sprinkler Wrench Model R2 or W2 Listings and Approvals cULus Listed Hazard Classification Light Hazard System Types Wet-pipe with steel or Listed CPVC pipe Dry-pipe with steel pipe Installation Criteria Sprinkler Spacing Max: 6 ft (1.8 m) across roof slope Min: 4 ft (1.2 m) across roof slope Min: 26 ft (7.9 m) down the roof slope measured parallel to the roof deck Horizontal Distance from Face of Truss Min: 6 inches (150 mm) Vertical Distance of Deflector Above Scis- sor Truss Min: 18 inches (450 mm) Horizontal Distance from Centerline of Ridge Max: 6 inches (150 mm) Vertical Distance of Deflector Below Peak, Ridge, or Deck Min: 17 inches (430 mm) Max: 21 inches (530 mm) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Levers: Stainless Steel Sprinkler Frame: Brass Alloy Button: Copper Alloy Button Clip: Stainless Steel Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Model DD80-27 Sprinkler Components and Dimensions Figure 4 Model DD80-27 Minimum Required Flow and Residual Pressure Table E Ceiling Slope Max. Coverage Area ft x ft (m x m) Flow gpm (l/min) Pressure psi (bar) 6:12 to 8:12 6 x 401 (1.8 x 12) 28 (106) 12.3 (0.85) 6 x 632 (1.8 x 19) 38 (144) 22.6 (1.56) 6 x 663 (1.8 x 20) 40 (151) 25 (1.72) 5 x 704 (1.5 x 21) 38 (144) 22.6 (1.56) 1 Coverage is 20 ft (6.1 m) down slope in two directions measured along the floor. 2 Coverage is 31.5 ft (9.6 m) down slope in two directions measured along the floor. 3 Coverage is 33 ft (10.0 m) down slope in two directions measured along the floor. 4 Coverage is 35 ft (10.7 m) down slope in two directions measured along the floor. Bulletin 056 Page 6 of 24 December 2016 www.reliablesprinkler.com Model DS56 Specific Application Sprinkler SIN RA5625 Technical Specifications Style: Upright Orientation: Frame arms perpendicular to roof deck Threads: 1/2” NPT or ISO 7-1R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Sprinkler Temperature Rating: 212°F (100°C) Sensitivity: Quick-response Hydraulic Design Criteria (See Tables F and H) Finish Brass Sprinkler Wrench Model DS56 Listings and Approvals cULus Listed Hazard Classification Light Hazard System Types Wet-pipe with steel or Listed CPVC pipe Dry-pipe with steel pipe Installation Criteria Sprinkler Spacing Max: 6 ft (1.8 m) across roof slope Min: 4 ft (1.2 m) across roof slope Min: 26 ft (7.9 m) down the roof slope measured parallel to the roof deck Horizontal Distance from Face of Truss Min: 6 inches (150 mm) Horizontal Distance from Draft Curtain or Wall Min: 34 inches (860 mm) Max: 38 inches (970 mm) Vertical Distance of Top of Deflector Above Bottom of Draft Curtain Min: 8 inches (200 mm) Model DS56 sprinklers may be installed back-to-back on opposite sides of a ridge where a draft curtain is installed to separate the back-to-back rows of sprinklers. Vertical Distance of Top of Deflector Above Scissor Truss Min: 18 inches (450 mm) Distance from Top of Deflector to Roof Deck (measured perpendicular to roof deck) Min: 9 inches (230 mm) Max: 13 inches (330 mm) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Levers: Brass Alloy Frame Body: Brass Alloy Frame Arms: Brass Alloy Yoke: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Model DS56 Sprinkler Components and Dimensions Figure 5 Model DS56 Minimum Required Flow and Residual Pressure Table F Ceiling Slope Max. Coverage Area ft x ft (m x m) Flow gpm (l/min) Pressure psi (bar) 4:12 to 8:12 6 x 301 (1.8 x 9.1) 23 (87) 16.9 (1.17) 6 x 402 (1.8 x 12) 35 (132) 39.1 (2.70) 1 Coverage is 30 ft (9.1 m) down slope measured along the floor. 2 Coverage is 40 ft (12 m) down slope measured along the floor. Bulletin 056 Page 7 of 24 December 2016 www.reliablesprinkler.com Model GP56 Specific Application Sprinkler SIN RA5695 Technical Specifications Style: Upright Orientation: Top of deflector parallel to roof deck Threads: 1/2” NPT or ISO 7-1R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Sprinkler Temperature Rating: 212°F (100°C) Sensitivity: Quick-response Hydraulic Design Criteria (See Tables G and H) Finish Brass Sprinkler Wrench Model R2 or W2 Listings and Approvals cULus Listed Hazard Classification Light Hazard System Types Wet-pipe with steel or Listed CPVC pipe Dry-pipe with steel pipe Installation Criteria Sprinkler Spacing Max: 10 ft (3.0 m) across roof slope measured along the floor Max: 15 ft (4.6 m) up and down roof slope measured along the floor Min: 6 ft (1.8 m) measured parallel to the roof deck Distance from Top of Deflector to Roof Deck (measured perpendicular to roof deck) Min: 9 inches (230 mm) Max: 13 inches (330 mm) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Levers: Stainless Steel Sprinkler Frame: Brass Alloy Button: Copper Alloy Button Clip: Stainless Steel Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Model GP56 Sprinkler Components and Dimensions Figure 6 Model GP56 Minimum Required Flow and Residual Pressure Table G Ceiling Slope Max. Coverage Area ft x ft (m x m) Flow gpm (l/min) Pressure psi (bar) 4:12 to 8:12 10 x 15* (3.0 x 4.6) 17 (64) 9.2 (0.63) * Coverage is 3 ft (0.9 m) up slope and 12 ft (3.7 m) down slope measured along the floor. Bulletin 056 Page 8 of 24 December 2016 www.reliablesprinkler.com Application Reliable Attic Sprinklers are cULus Specific Application sprinklers intended for installation in accordance with this Bulletin and NFPA 13. The sprinklers are classified as Special Sprinklers by NFPA 13. The sprinklers are intended for installation within combus- tible or noncombustible roof structures, including those with wood joists or trusses. Coverage area and spacing requirements for each sprin- kler are provided on the individual sprinkler data sheets in this Bulletin. Example sprinkler layouts are illustrated in Figures 7 through 21. Design criteria for Reliable Attic Sprinklers must be in accordance with Table H based on the minimum flows and pressures for each sprinkler in Ta- bles B through G. Provide additional sprinklers beyond obstructions where required by Figure 22. For example, hydraulic calculations for a sprinkler system using DD Series sprinklers at the ridge with Model GP56 sprinklers at the eave must include the hydraulically most remote 5 DD Series sprinklers plus 2 Model GP56 sprin- klers for a wet pipe sprinkler system or 7 DD Series sprin- klers plus 2 Model GP56 sprinklers for a dry pipe sprinkler system. Bulletin 056 Page 9 of 24 December 2016 www.reliablesprinkler.com Reliable Attic Sprinkler Hydraulic Design Criteria Table H Sprinklers in Attic Number or (Area) of Sprinklers Included in Hydraulic Design (Select Hydraulically Most Remote Sprinklers of Each Type) Wet Pipe Sprinkler System Dry Pipe Sprinkler System aa= pÉêáÉë=apRS= dmRS= pí~åÇ~êÇ= péê~ó= aa= pÉêáÉë=apRS= dmRS= pí~åÇ~êÇ= péê~ó= DD Series at ridge only (Fig. 7) 5 N/A N/A N/A 7 N/A N/A N/A DS56 at ridge only (Fig. 8) N/A 5 N/A N/A N/A 9 N/A N/A DD Series at ridge with DS56 beyond obstruction (Fig. 9) 5 2 N/A N/A 7 2 N/A N/A DS56 at ridge with DS56 beyond ob- struction (Fig. 10) N/A 5 N/A N/A N/A 9 N/A N/A DD Series at ridge with GP56 beyond obstruction (Fig. 11) 5 N/A 2 N/A 7 N/A 2 N/A DS56 at ridge with GP56 beyond ob- struction (Fig. 12) N/A 5 2 N/A N/A 9 2 N/A DD Series at ridge with GP56 in dormer or cross (Fig. 13) (Calculate upper row if 4 or less GP56 sprinklers are used in each dormer or cross; Separately calculate upper row and lower row if more than 4 GP56 sprin- klers are used in any dormer or cross and use the greater demand) 5 N/A 2 N/A 7 N/A 2 N/A 0 N/A (1,500 ft2) (139 m2) N/A 0 N/A (1,950 ft2) (181 m2) N/A DD Series at ridge with Standard Spray sprinklers in dormer or cross (Fig. 14) (Calculate upper row if 4 or less Standard Spray sprinklers are used in each dormer or cross; Separately calculate upper row and lower row if more than 4 Standard Spray sprinklers are used in any dor- mer or cross and use the greater de- mand) 5 N/A N/A 2 7 N/A N/A 2 Calculate design area per NFPA 13 and include all sprinkler types that are in the design area Calculate design area per NFPA 13 and include all sprinkler types that are in the design area DD Series at ridge with DD Series in dormer (Fig.15) 5 at ridge and up to 2 in dormer N/A N/A N/A 7 at ridge and up to 2 in dormer N/A N/A N/A DD Series sprinklers at ridge with GP56 sprinklers at eave (Fig. 16) 5 N/A 2 N/A 7 N/A 2 N/A DS56 sprinklers at ridge with GP56 sprinklers at eave (Fig. 17) N/A 5 2 N/A N/A 9 2 N/A DD Series sprinklers at ridge with DS56 sprinklers at hip or ell (Fig. 18) 5 total N/A N/A 9 total (Include a max. of 7 DD Series sprinklers in hydraulic design) N/A N/A DS56 sprinklers at ridge with DS56 sprinklers at hip or ell (Fig. 19) N/A 5 N/A N/A N/A 9 N/A N/A DD Series sprinklers at ridge with Standard Spray sprinklers at hip or ell (Fig. 20) (Calculate upper row if 4 or less Standard Spray sprinklers are used in each hip or ell; Separately calculate upper row and lower row if more than 4 Standard Spray sprinklers are used in any hip or ell and use the greater de- mand) 5 N/A N/A 2 7 N/A N/A 2 Calculate design area per NFPA 13 and include all sprinkler types that are in the design area Calculate design area per NFPA 13 and include all sprinkler types that are in the design area DS56 sprinklers at ridge with Standard Spray sprinklers at hip or ell (Fig. 21) (Calculate upper row if 4 or less Standard Spray sprinklers are used in each hip or ell; Separately calculate upper row and lower row if more than 4 Standard Spray sprinklers are used in any hip or ell and use the greater de- mand) N/A 5 N/A 2 N/A 9 N/A 2 Calculate design area per NFPA 13 and include all sprinkler types that are in the design area Calculate design area per NFPA 13 and include all sprinkler types that are in the design area Bulletin 056 Page 10 of 24 December 2016 www.reliablesprinkler.com Model DD Series Sprinkler – Example Layout (Not to Scale) Figure 7 Model DS56 Sprinkler – Example Layout (Not to Scale) Figure 8 Bulletin 056 Page 11 of 24 December 2016 www.reliablesprinkler.com Model DD Series Sprinklers at Ridge with Model DS56 Sprinklers Beyond Obstruction Example Layout (Not to Scale) Figure 9 Model DS56 Sprinklers at Ridge with Model DS56 Sprinklers Beyond Obstruction Example Layout (Not to Scale) Figure 10 Bulletin 056 Page 12 of 24 December 2016 www.reliablesprinkler.com Model DD Series Sprinklers at Ridge with Model GP56 Sprinklers Beyond Obstruction Example Layout (Not to Scale) Figure 11 Model DS56 Sprinklers at Ridge with Model GP56 Sprinklers Beyond Obstruction Example Layout (Not to Scale) Figure 12 Bulletin 056 Page 13 of 24 December 2016 www.reliablesprinkler.com Model DD Series Sprinklers at Ridge with Model GP56 Sprinklers at Dormer or Cross Example Layout (Not to Scale) Figure 13 Bulletin 056 Page 14 of 24 December 2016 www.reliablesprinkler.com Model DD Series Sprinklers at Ridge with Standard Spray Sprinklers at Dormer or Cross Example Layout (Not to Scale) Figure 14 Bulletin 056 Page 15 of 24 December 2016 www.reliablesprinkler.com Model DD Series Sprinklers at Ridge with Model DD Series Sprinklers in Dormers Example Layout (Not to Scale) Figure 15 Model DD Series Sprinklers at Ridge with Model GP56 Sprinklers at Eave Example Layout (Not to Scale) Figure 16 Bulletin 056 Page 16 of 24 December 2016 www.reliablesprinkler.com Model DS56 Sprinklers at Ridge with Model GP56 Sprinklers at Eave Example Layout (Not to Scale) Figure 17 Model DD Series Sprinklers at Ridge with DS56 Sprinklers at Hip or Ell Example Layout (Not to Scale) Figure 18 Bulletin 056 Page 17 of 24 December 2016 www.reliablesprinkler.com Model DS56 Sprinklers at Ridge with DS56 Sprinklers at Hip or Ell Example Layout (Not to Scale) Figure 19 Model DD Series Sprinklers at Ridge with Standard Spray Sprinklers at Hip or Ell Example Layout (Not to Scale) Figure 20 Bulletin 056 Page 18 of 24 December 2016 www.reliablesprinkler.com Model DS56 Sprinklers at Ridge with Standard Spray Sprinklers at Hip or Ell Example Layout (Not to Scale) Figure 21 Bulletin 056 Page 19 of 24 December 2016 www.reliablesprinkler.com Obstruction Criteria Figure 22 Additional sprinklers not required due to obstruction 6” (150 mm) or less in height with a minimum 3-1/2” (90 mm) gap provided between the top of the obstruction and the roof deck. Additional sprinklers required beyond obstruction greater than 6” (150 mm) in height or where a minimum 3-1/2” (90 mm) gap is not provided between the top of the obstruction and the roof deck. Additional sprinklers not required due to obstruction 6” (150 mm) or less in height with a minimum 3-1/2” (90 mm) gap provided between the top of the obstruction and the roof deck. Additional sprinklers required beyond obstruction greater than 6” (150 mm) in height or where a minimum 3-1/2” (90 mm) gap is not provided between the top of the obstruction and the roof deck. Additional sprinklers not required below horizontal obstruction 4’-0” (1.2 m) or less in width. Additional sprinklers required below horizontal obstruction greater than 4’-0” (1.2 m) in width. Additional sprinklers not required beyond horizontal obstruction more than 6” from bottom of rafter. Additional sprinkler required beyond horizontal obstruction less than 6” (150 mm) from bottom of rafter. Additional sprinkler not required beyond vertical obstruction (see figure at left) where: Obstruction width, W Minimum distance between sprinkler and obstruction, D 1” or less (25 mm or less) 6” (150 mm) 1” to 4” (25 to 100 mm) 1’-0” (300 mm) 4” to 8” (100 to 200 mm) 2’-0” (600 mm) 8” to 10” (200 to 250 mm) 5’-0” (1.5 m) 10” to 20” (250 to 500 mm) 10’-0” (3.0 m) 20” to 30” (500 to 750 mm) 15’-0” (4.5 m) 30” to 40” (750 to 1000 mm) 20’-0” (6.0 m) 40” to 48” (1000 to 1200 mm) 25’-0” (7.5 m) Provide sprinklers beyond vertical obstructions not meeting the criteria above. Bulletin 056 Page 20 of 24 December 2016 www.reliablesprinkler.com Obstruction Criteria (Continued) Figure 22 Additional sprinklers not required beyond enclosed space more than 3'-0" (900 mm) from roof deck Intermediate level sprinklers required beyond enclosed space less than 3’-0” (900 mm) to 1’-0” (300 mm) from roof deck Additional sprinklers required beyond enclosed space less than 1’-0” (300 mm) from roof deck Additional sprinkler not required below stiffeners meeting all of the following criteria: (1) min. 1’-0” (300 mm) below Reliable Attic sprin- klers, (2) max. 7-1/2” (190 mm) wide, (3) min. 1’-0” (300 mm) gaps between stiffeners, and (4) min. 70% open area. Additional sprinklers required below stiffeners: (1) less than 1’-0” (300 mm) below Reliable Attic sprinklers, (2) more than 7-1/2” (190 mm) in width, (3) where gaps between stiffeners are less than 1’-0” (300 mm), or (4) where the area of the horizontal plane where the stiffeners are located is less than 70% open. Bulletin 056 Page 21 of 24 December 2016 www.reliablesprinkler.com Listing & Approval Agency Underwriters Laboratories, Inc. and UL Canada (cULus) Listing Category: Sprinklers, Automatic and Open Guide Number: VNIV, VNIV7 Installation Reliable Attic sprinklers are intended to be installed in ac- cordance with NFPA 13 and the requirements of other ap- plicable authorities having jurisdiction. In addition, Reliable Attic sprinklers must also be installed in accordance with the requirements contained in this Bulletin. Installation Reliable Attic Sprinklers only in the orientation specified in Figure 23. Installation Orientation Figure 23 jçÇÉä=aa=pÉêáÉë= Install Model DD Series sprinklers with the deflector parallel to the floor and arrows on deflector pointing down the roof slope in both directions. = = jçÇÉä=apRS= Install Model DS56 sprinklers with the frame arms per- pendicular to the roof deck and the arrow on the de- flector pointing down the roof slope. = jçÇÉä=dmRS= Install Model GP56 sprinklers with the deflector parallel to the roof deck and the arrow on the deflector pointing down the roof slope. Follow installation requirements specified in the individual sprinkler data sheets in this bulletin. Figure 24 illustrates select installation criteria for each sprinkler. Installation Dimensions Figure 24 jçÇÉä=aa=pÉêáÉë= = = jçÇÉä=apRS= = jçÇÉä=dmRS= Where Reliable Attic Sprinklers are installed on wet-pipe sprinkler systems with CPVC pipe, the CPVC pipe must be protection in accordance with the pipe manufacturer’s in- stallation instruction as well as the requirements in Figure 25. Bulletin 056 Page 22 of 24 December 2016 www.reliablesprinkler.com Installation Requirements for Use of Reliable Attic Sprinklers with Listed CPVC Pipe Figure 25 Min.18" (450 mm)Heat producing or releasing device Maintain at least 18" (450 mm) between CPVC pipe and heat producing or releasing devices. Vertical Sprig Armover Sprig Angled Sprig Direct Mount Offset (A) must not exceed 6" (150 mm) Install sprinklers on CPVC pipe only in the follow- ing configurations: (1) directly mounted to a fitting on the branch line pipe, (2) on an angled sprig where the horizontal distance between the sprin- kler and the branch line does not exceed 6” (150 mm), (3) on an armover sprig where the horizontal distance between the sprinkler and the branch line does not exceed 6” (150 mm), or (4) on a ver- tical sprig. Max. 1'-0" (300 mm) CPVC Riser Locate a sprinkler within 1’-0” (300 mm) horizontally of CPVC risers Max. 3'-0" (900 mm) Min. 1'-0" (300 mm) Min. 1'-0" (300 mm) Min. 6" (150 mm) Joist Noncombustible insulation (e.g., fiberglass) Angled sprig Model GP56 sprinkler Branch lines over joists must be protected with a minimum 6” (150 mm) thickness of noncombus- tible insulation (e.g., fiberglass). A maximum of 3’- 0” (900 mm) of an angled sprig may extend above the insulation to supply Model GP56 sprin- klers. Vertical sprig Branch lines over joists must be protected with a minimum 6” (150 mm) thickness of noncombustible insulation (e.g., fiberglass). A maximum of 10’-0” (3 m) of a vertical sprig may extend above the insula- tion to supply Model GP56 sprinklers. `~ìíáçåW= 1. Insulation required by Figure 25 is for fire protection purposes and not for freeze protection. 2. Follow installation requirements of the CPVC pipe manufacturer and listing, including verifying compatibility of any insulation or other materials used with CPVC pipe. Bulletin 056 Page 23 of 24 December 2016 www.reliablesprinkler.com Installation Requirements for Use of Reliable Attic Sprinklers with Listed CPVC Pipe (Continued) Figure 25 Max. 3'-0" (900 mm)Angled sprig Model GP56 sprinkler Joist Noncombustible insulation (e.g., fiberglass) Min. 6" (150 mm) Max. 3'-0" (900 mm)Angled sprig Model GP56 sprinkler Joist Noncombustible insulation (e.g., fiberglass) Min. 6" (150 mm) Branch lines between joists must be protected with a minimum 6” (150 mm) thickness of noncombus- tible insulation (e.g., fiberglass) either within the joist bay or on top of the joists. A maximum of 3’-0” (900 mm) of an angled sprig may extend above the insulation to supply Model GP56 sprinklers. Model GP56 sprinkler Joist Noncombustible insulation (e.g., fiberglass) Min. 6" (150 mm)Max. 10'-0" (3 m) Model GP56 sprinkler Joist Noncombustible insulation (e.g., fiberglass) Min. 6" (150 mm)Max. 10'-0" (3 m) Branch lines between joists must be protected with a minimum 6” (150 mm) thickness of noncombus- tible insulation (e.g., fiberglass) either within the joist bay or on top of the joists. A maximum of 10’-0” (3 m) of a vertical sprig may extend above the insulation to supply Model GP56 sprinklers. `~ìíáçåW= 1. Insulation required by Figure 25 is for fire protection purposes and not for freeze protection. 2. Follow installation requirements of the CPVC pipe manufacturer and listing, including verifying compatibility of any insulation or other materials used with CPVC pipe. Bulletin 056 Page 24 of 24 December 2016 www.reliablesprinkler.com Model DD56, DD80, and GP56 sprinklers are installed with the Model R2 or W2 wrench. The Model DS56 wrench is used to install Model DS56 sprinklers. The use of any other wrench to installed Reliable Attic sprinklers is not permitted and may damage the sprinkler. Insert the specified wrench over the sprinkler until the wrench engages the wrench flats. Do not wrench any other part of the sprinkler assem- bly. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler’s threads. Rec- ommended installation torque is specified in Table I. Installation Torque Table I Sprinkler Threads Recommended Installation Torque (min. – max.) ft-lb N-m ½” NPT or ISO7-1R1/2 8-18 11-24 ¾” NPT or ISO7-1R3/4 14-20 19-27 Do not exceed the maximum recommended torque. Ex- ceeding the maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when in- serting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Installation Wrenches Figure 26 = jçÇÉä=oO=têÉåÅÜ=EjçÇÉä=tO=têÉåÅÜ=ëáãáä~êF= = ==cçê=jçÇÉä=aaRSI=aaUMI=~åÇ=jçÇÉä=dmRS=ëéêáåâäÉêë= = jçÇÉä=apRS=têÉåÅÜ =cçê=jçÇÉä=apRS=ëéêáåâäÉêë= Maintenance Reliable Attic sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Ju- risdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause im- proper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Replace any sprinkler which has been damaged. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inad- vertent operation or non-operation during a fire event. Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Ordering Information Specify the following when ordering. Sprinkler Model (DD56-6, DD56-27, DD80-6, DD80-27, DS56, GP56) Threads (NPT or ISO 7-1) Sprinkler Wrench Model R2 or W2 (for Model DD56, DD80, and GP56 sprinklers) Model DS56 (for Model DS56 sprinklers) P/ N 9 9 9 9 9 7 0 4 9 7 Series TY-L — 5.6 and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage Page 1 of 6 NOVEMBER 2015 TFP110 IMPORTANTAlways refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal-lation of sprinkler systems and com-ponents. Improper handling and installation can permanently damage a sprinkler system or its compo-nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com General Description The TYCO Series TY-L, 5.6 and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers described in this data sheet are stan-dard response, standard coverage, solder type spray sprinklers designed for use in light, ordinary, and extra hazard, commercial occupancies such as banks, hotels, shopping malls, fac-tories, refineries, chemical plants, etc. The recessed version of the Series TY-L Pendent Sprinkler, where appli-cable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprin-klers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo-spheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the appli-cable approval agencies, the testing is not representative of all possible cor-rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit-ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-L Pendent Sprinkler can be obtained by utilizing the Series TY-L Pendent Sprinkler in combination with the Model S Shield. NOTICE The TYCO Series TY-L, 5.6 and 8.0 K-factor, Upright and Pendent Sprin-klers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori-ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main-taining their fire protection system and devices in proper operating con-dition. Contact the installing contrac-tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY3111 . . . . . .Upright 5 .6K, 1/2” NPT TY3211 . . . .Pendent 5 .6K, 1/2” NPTTY4111 . . . . .Upright 8 .0K, 3/4” NPTTY4211 . . . . .Pendent 8 .0K, 3/4” NPT TY4811 . . . . .Upright 8 .0K, 1/2” NPT TY4911 . . . .Pendent 8 .0K, 1/2” NPT TY3111 is a re-designation for S1800 and G3111.TY3211 is a re-designation for S1801 and G3112.TY4111 is a re-designation for S1810 and G3101.TY4211 is a re-designation for S1811 and G3102.TY4811 is a re-designation for S1805.TY4911 is a re-designation for S1806. TFP110 Page 2 of 6 *** *** * UPRIGHT PENDENT CROSS SECTIONRECESSED PENDENT 2-5/8"(66,7 mm) 7/16"(11,1 mm)NOMINALMAKE-IN 2-5/8"(66,7 mm) 2" (50,8 mm) WRENCHFLANGES ESCUTCHEONPLATE SEATINGSURFACE 2-7/8" (73,0 mm) DIA. WRENCH AREA 3 STYLE 20 RECESSED ESCUTCHEON 7 5 6 4 2 1 Pipe thread connections perISO 7-1 can be provided onspecial request. Temperature ratingis indicated onDeector. 12 SealingButton Frame-- Fusible Element - -4 3 EjectionSpring Hook 7 -Deector Strut-6 -5 1/2" NPT * * ** *** UPRIGHT PENDENT CROSS SECTIONRECESSED PENDENT 2" (50,8 mm) WRENCHFLANGES ESCUTCHEONPLATE SEATINGSURFACE WRENCHAREA STYLE 30RECESSEDESCUTCHEON Pipe thread connections perISO 7-1 can be provided onspecial request. Temperature ratingis indicated onDeector. 3 7 6 5 4 2 1 5 -StrutEjection3--Frame1 Element Fusible Sealing Button 2 -Spring 4 -Deector - -7 6 Hook 3/4" NPT 2-7/8" (73,0 mm) DIA. 2-11/16"(68,3 mm) 2-11/16" (68,3 mm)1/2"(12,7 mm)NOMINALMAKE-IN FIGURE 1 STANDARD RESPONSE SERIES TY-L UPRIGHT (TY3111) AND PENDENT (TY3211) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT FIGURE 2 STANDARD RESPONSE SERIES TY-L UPRIGHT (TY4111) AND PENDENT (TY4211) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT TFP110 Page 3 of 6 Technical Data ApprovalsUL and C-UL Listed. FM, and LPCB Approved. (Refer to Table A for complete approval information including corrosion resistant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge CoefficientK=5.6 GPM/psi½ (80,6 LPM/bar½) K=8.0 GPM/psi½ (115,2 LPM/bar½) Temperature Ratings Refer to Table A FinishesSprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical CharacteristicsFrame . . . . . . . . . . . . . . . . . . . . . . . . . . . . .BrassSealing Button . . . . . . . . . . . Bronze w/TEFLONEjection Spring . . . . . . . . . . . . . . Stainless SteelStrut . . . . . . . . . . . . . . . . . . . . . . . . . . . . MONELHook .....................Bronze/MONELDeflector . . . . . . . . . . . . . . . . . . . . . . . . . .BronzeFusible Element. . . . . . . . . . . . . .Solder, Copper, Stainless SteelOperation A copper tube sealed by two stainless steel balls holds a fusible alloy. When the rated temperature is reached, the alloy melts, the balls are forced toward each other releasing the tension mech-anism, allowing the sprinkler to operate. Design Criteria The TYCO Series TY-L, 5.6 and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan-dard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the require-ments of NFPA 13, and FM Approval is based on the requirements of FM’s Loss Prevention Data Sheets). Only the Style 20 or 30 Recessed Escutch-eon, as applicable, are to be used for recessed pendent installations. Installation The TYCO Series TY-L, 5.6 and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section: A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuf-ficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Series TY-L Pendent and Upright Sprinkler InstallationThe Series TY-L Pendent and Upright Sprinklers must be installed in accor-dance with this section. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 1. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 9 Sprinkler Wrench (Ref. Figure 7), except that an 8 or 10 inch adjust-able Crescent wrench is to be used for wax coated sprinklers. With refer-ence to Figures 1, 2, and 3, the W-Type 9 Sprinkler Wrench is to be applied to the wrench area, or as applicable, the adjustable Crescent wrench is to be applied to the wrenching flanges. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ-ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damaging the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just contact the sprin-kler wrench flats. After wrench tight-ening the sprinkler, loosen the wrench jaws before removing the wrench. *** *** * UPRIGHT PENDENT CROSS SECTIONRECESSED PENDENT 2-5/8"(66,7 mm) 7/16"(11,1 mm)NOMINALMAKE-IN 2-5/8"(66,7 mm) 2" (50,8 mm) WRENCHFLANGES ESCUTCHEONPLATE SEATINGSURFACE 2-7/8" (73,0 mm) DIA. WRENCH AREA 3 STYLE 20 RECESSED ESCUTCHEON 7 5 6 4 2 1 Pipe thread connections perISO 7-1 can be provided onspecial request. Temperature ratingis indicated onDeector. 12 SealingButton Frame-- Fusible Element - -4 3 EjectionSpring Hook 7 -Deector Strut-6 -5 1/2" NPT FIGURE 3 STANDARD RESPONSE SERIES TY-L UPRIGHT (TY4811) AND PENDENT (TY4911) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT TFP110 Page 4 of 6 After installation, the sprinkler wrench flats and frame arms must be inspected and the wax coating retouched (repaired) whenever the coating has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gently applying a heated 1/8 in. diam-eter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTICE Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precau-tions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. If attempts to retouch the wax coating with complete coverage are unsuc-cessful, additional wax can be ordered in the form of a wax stick (the end of which is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previously described, touch the rod to the area requiring additional wax with the rod angled downward, and then touch the wax stick to the rod approximately one-half inch away from the area requiring retouching. The wax will melt and run down onto the sprinkler. Series TY-L Recessed Pendent Sprinklers InstallationThe Series TY-L Recessed Pendent Sprinklers must be installed in accor-dance with this section. Step A. After installing the Style 20 or 30 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 10 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 1, 2, or 3, the W-Type 10 Recessed Sprinkler Wrench is to be applied to the sprinkler wrenching flanges. Step C. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 or 30 Closure over the Series TY-L Sprin-kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. NOTES:1. UL Listed2. C-UL Listed3. FM Approved4. FM Approved for maximum 150°F (68°C) ambient temperatures5. LPCB Approved (LPCB Ref. No. 094a/03) N/A: Not Available K Type Temp. Rating Frame Color Code Sprinkler Finish Natural Brass Chrome Plated Lead Coated Wax Coated Wax Over Lead Coated 5.6 1/2” NPT Pendent (TY3211) and Upright (TY3111) 165°F (74°C)Unpainted 1, 2, 3, 5 1, 2, 3212°F (100°C)White 280°F (138°C)Blue 1, 2 4 N/A Recessed Pendent (TY3211 w/Style 20) 165°F (74°C)Unpainted 1, 2, 3, 5 N/A212°F (100°C)White 1, 2, 3, 5 8.0 3/4” NPT Pendent (TY4211) 165°F (74°C)Unpainted 1, 2, 3 1, 2, 3212°F (100°C)White 280°F (138°C)Blue 1, 2 4 N/A Upright (TY4111) 165°F (74°C)Unpainted 1, 2, 3, 5 1, 2, 3212°F (100°C)White 280°F (138°C)Blue 1, 2 4 N/A Recessed Pendent (TY4211 w/Style 30) 165°F (74°C)Unpainted 1, 2, 5 N/A212°F (100°C)White 8.0 1/2” NPT Pendent (TY4911) and Upright (TY4811) 165°F (74°C)Unpainted 1, 2, 3, 5 1, 2, 3212°F (100°C)White 280°F (138°C)Blue 1, 2 N/A Recessed Pendent (TY4911 w/Style 20) 165°F (74°C)Unpainted 1, 2 N/A212°F (100°C)White TABLE A LABORATORY LISTINGS AND APPROVALS TFP110 Page 5 of 6 Care and Maintenance The TYCO Series TY-L, 5.6 and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi-fied or over-heated sprinklers must be replaced. Care must be exercised to avoid damage to the sprinklers -before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Frequent visual inspections are rec-ommended to be initially performed for corrosion resistant coated sprin-klers, after the installation has been CLOSURE MOUNTING SURFACE FACE OFSPRINKLERFITTING 7/16±1/8"(11,1±3,2 mm)1/4" (6,4 mm) TY-L 2-1/4" DIA.(57,2 mm) 1-1/2" (38,1 mm) MOUNTINGPLATE 1-3/4" (44,5 mm) 1/8"(3,2 mm) 2-7/8" DIA.(73,0 mm)1/2" (12,7 mm) MOUNTING SURFACE FACE OF SPRINKLER FITTING 7/16±1/8"(11,1±3,2 mm) 2-1/4" DIA. (57,2 mm) MOUNTING PLATE 1/8" (3,2 mm) 2-7/8" DIA.(73,0 mm) CLOSURE TY-L 1-1/2" (38,1 mm) 1-3/4" (44,5 mm) 1/4" (6,4 mm) 1/2" (12,7 mm) MOUNTINGSURFACE FACE OF SPRINKLER FITTING 7/16±1/8" (11,1±3,2 mm) 2-1/4" DIA. (57,2 mm) MOUNTING PLATE 1/8"(3,2 mm) 2-7/8" DIA. (73,0 mm) CLOSURE 1/4" (6,4 mm) TY-L 1-1/2" (38,1 mm)1-3/4" (44,5 mm) 1/2" (12,7 mm) WRENCH RECESS WRENCH RECESSFIGURE 4 SERIES TY-L (TY3211) RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT FIGURE 5 SERIES TY-L (TY4211) RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT FIGURE 6 SERIES TY-L (TY4911) RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 8.0 K-FACTOR, 1/2 INCH NPT FIGURE 7 W-TYPE 9 SPRINKLER WRENCH FIGURE 8 W-TYPE 10 RECESSED SPRINKLER WRENCH GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP110 Page 6 of 6 Copyright © 2015 Tyco Fire Products, LP. All rights reserved.MONEL is trademark of Special Metals Corporation.TEFLON is trademark of The DuPont Corporation completed, to verify the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso-ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install-ing contractor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspec-tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail-ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread ConnectionsSpecify: Series TY-L (specify SIN), (specify K-factor), (specify Upright, Pendent, or Recessed Pendent) Sprin-kler, Standard Response, Standard Coverage, (specify) temperature rating, (specify) finish or coating, P/N (specify from Table B) Recessed EscutcheonSpecify: Style (specify) Recessed Escutcheon with (specify finish), P/N (specify): 1/2” (15 mm)Style 20Brass Plated..............P/N 56-705-2-0101/2” (15 mm)Style 20Signal White (RAL9003). . . . . P/N 56-705-4-0101/2” (15 mm)Style 20Chrome Plated............P/N 56-705-9-0103/4” (20 mm)Style 30Brass Plated..............P/N 56-705-2-0113/4” (20 mm)Style 30Signal White (RAL9003). . . . . P/N 56-705-4-0113/4” (20 mm)Style 30Chrome Plated............P/N 56-705-9-011 Sprinkler WrenchSpecify: W-Type 9 Sprinkler Wrench, P/N 56-000-1-849 Specify: W-Type 10 Sprinkler Wrench, P/N 56-000-1-948 Wax Sticks (for retouching wrench damaged wax coating)Specify: Series TY-L Sprinklers, (specify color), color coded Wax Stick for retouching, (specify) temperature rated, P/N (specify): Red for 165°F (74°C) . . . . . . . P/N 56-065-1-155 Blue for 212°F (100°C) and 280°F (138°C) .........P/N 56-065-1-286 NOTES:Each wax stick is suitable for retouch-ing up to twenty-five sprinklers. The wax used for 280°F (138°C) sprin-klers is the same as for 212°F (100°C)sprinklers, and, therefore, the 280°F (138°C) sprinkler is limited to the same maximum ceiling temperature as the 212°F (100°C) sprinkler (i.e., 150°F (65°C)). SIN 111 5.6K UPRIGHT (1/2”NPT)TY3111 112 5.6K PENDENT (1/2”NPT)TY3211 101 8.0K UPRIGHT (3/4”NPT)TY4111 102 8.0K PENDENT (3/4”NPT)TY4211 106 8.0K UPRIGHT (1/2”NPT)TY4811 107 8.0K PENDENT (1/2”NPT)TY4911 SPRINKLER FINISH 1 NATURAL BRASS 6 WAX COATED 165°F TO 280°F ONLY 7 LEAD COATED 8 WAX OVER LEAD 165°F TO 212°F ONLY 9 CHROME PLATED TEMPERATURE RATING 165 165°F (74°C) 212 212°F (100°C) 280 280°F (138°C) P/N 53 - XXX - X - XXX TABLE B SERIES TY-L PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Series TY-FRL – 5.6 K-factor Horizontal Sidewall Sprinkler Quick Response, Standard Coverage Worldwide Contacts www.tyco-fire.com Page 1 of 4 DECEMBER 2016 TFP140 IMPORTANTAlways refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal-lation of sprinkler systems and com-ponents. Improper handling and installation can permanently damage a sprinkler system or its compo-nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. General Description TYCO Series TY-FRL 5.6K Horizon-tal Sidewall Sprinklers (HSW), Quick Response, Standard Coverage are sol-der-type spray sprinklers designed for use in light and ordinary hazard com-mercial occupancies such as banks, hotels, shopping malls, offices, etc. They are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling. Horizontal sidewall sprinklers are commonly used instead of pendent or upright sprin-klers due to aesthetics or building con-struction considerations, where piping across the ceiling is not desirable. NOTICE The Series TY-FRL Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica-ble standards of the National Fire Pro-tection Association (NFPA), in addition to the standards of any other authori-ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main-taining their fire protection system and devices in proper operating con-dition. Contact the installing contrac-tor or product manufacturer with any questions. Sprinkler Identification Numbers (SINs) TY3321 – HSW 5.6K, 1/2”NPT TY3321 is a re-designation for Star SIN S1878 and Gem SIN G8946. Technical Data Approvals UL and C-UL Listed FM and NYC Approved (Refer to Table A for complete approval information.) Maximum Working Pressure 175 psi (12,1 bar) Discharge CoefficientK=5.6 gpm/psi½ (80,6 lpm/bar½) Temperature Ratings Refer to Table A FinishesRefer to Table A Physical Characteristics Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Strut. . . . . . . . . . . . . . . . . . . . . . . . . . . . . MONEL Deflector . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Hook . . . . . . . . . . . . . . . . . . . . . . . . . . . . MONEL Link Assembly . . . . . . . . . . . . . . . . . . . . . . Nickel Ejection Spring . . . . . . . . . . . . . . . . . . INCONEL Button . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . .TEFLON Operation The fusible link (heat collector) assem-bly is comprised of two halves that are joined together by a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate, allowing the sprin-kler to operate. Design Criteria TYCO Series TY-FRL 5.6K HSW Sprin-klers, Quick Response, Standard Coverage are intended for fire pro-tection systems designed in accor-dance with the standard installation rules recognized by the applicable listing or approval agency (e.g., UL Listing is based on NFPA 13 require-ments); however, the minimum dis-tance between sprinklers to prevent cold soldering is 8 feet (2,4 m). The Series TY-FRL HSW Sprinklers must be installed with a deflector-to-ceiling distance of 4 to 6 inches (100 to 150 mm). To meet this require-ment the centerline of the sprinkler waterway must be located 4-5/16 to 6-5/16 inches (110 to 160 mm) below the ceiling. Installation of the Series TY-FRL HSW Sprinklers in recessed escutcheons will void all manufac-turer’s warranties, as well as possibly void the sprinkler’s approvals and/or listings. TFP140 Page 2 of 4 Installation TYCO Series TY-FRL 5.6K HSW Sprin-klers, Quick Response, Standard Cov-erage must be installed in accordance with this section. General InstructionsA leak-tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 lbs-ft. (9,5 to 19,0 Nm). A maximum of 21 lbs-ft. (28,5 Nm) of torque may be used to install sprin-klers with 1/2 NPT connections. Higher levels of torque may distort the sprin-kler inlet and cause leakage or impair-ment of the sprinkler. Do not attempt to make-up for insuf-ficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Horizontal Sidewall SprinklersNote: The Series TY-FRL HSW Sprin-klers must be installed with their cen-terline of waterway parallel to the ceiling and perpendicular to the back wall surface. The word “TOP” on the deflector must face upwards toward the ceiling. Step 1. After installing an escutcheon (as applicable) over the sprinkler pipe threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 9 Sprinkler Wrench (Ref. Figure 2). With reference to Figure 1, the W-Type 9 Sprinkler Wrench is to be applied to the wrench area. K FACTOR SPRINKLER TYPE TEMPERATURE RATING FRAME COLOR CODE SPRINKLER FINISH NATURAL BRASS CHROME PLATED 5.6 1/2” NPT HORIZONTAL SIDEWALL (TY3321) 165°F (74°C)Unpainted 1, 2, 3, 4 212°F (100°C)White Notes:1. UL Listed for light or ordinary hazard occupancies as Quick Response sprinklers2. C-UL Listed for light or ordinary hazard occupancies as Quick Response sprinklers3. FM Approved for light hazard occupancies Quick Response sprinklers4. Approved by the City of New York under MEA 112-04-E WRENCHRECESS 21 4 7 63 5 8 ISO 7-1 can be provided onPipe thread connections per Temperature rating is indicatedButtonStrut Deector Frame AssemblyLink Hook Ejection Spring Seal on Deector special request * ** * *** WATERWAY OF SPRINKLER CENTERLINE SURFACEPLATE SEATING WALL TO P (15,9 mm)5/8" NOMINAL 5/16" (7,9 mm) DEFLECTOR BOSS (41,3 mm) DEFLECTOR 1-5/8" 3.5° 2-11/16"(68,3 mm) 7/16" (11,1 mm) NOMINAL MAKE-IN (50,8 mm)2" WRENCH AREA 6 3 4 5 2 7 WRENCH FLANGES 1/2" NPT 8 1 -- - - -- -- FIGURE 1 QUICK RESPONSE SERIES TY-FRL (TY3321) HORIZONTAL SIDEWALL SPRINKLER 5.6 K-FACTOR, 1/2 INCH NPT FIGURE 2 W-TYPE 9 SPRINKLER WRENCH TABLE A LABORATORY LISTINGS AND APPROVALS TFP140 Page 3 of 4 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail-ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread ConnectionsSpecify: Series TY-FRL 5.6K Quick Response Horizontal Sidewall Sprin-klers, SIN TY3321, (specify) temperature rating, (specify) finish, P/N (specify from Table B) Sprinkler WrenchSpecify: W-Type 9 Sprinkler Wrench, P/N 56-000-1-849 Care and Maintenance TYCO Series TY-FRL 5.6K HSW Sprin-klers, Quick Response, Standard Cov-erage must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi-fied or over-heated sprinklers must be replaced. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re placed. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso-ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install-ing contractor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspec-tion Service in accordance with local requirements and/or national codes. P/N 58 — XXX — X — XXX SPRINKLER FINISH 1 NATURAL BRASS 9 CHROME PLATED SIN 946 5.6K HSW (1/2” NPT)TY3321 TEMPERATURE RATING 165 165°F (74°C) 212 212°F (100°C) TABLE B SERIES TY-FRL HORIZONTAL SIDEWALL SPRINKLERS, QUICK RESPONSE PART NUMBER SELECTION GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP140 Page 4 of 4 Copyright © 2004 Tyco Fire Products, LP. All rights reserved.MONEL and INCONEL are registered trademarks of Special Metals Corporation TEFLON is a registered trademark of DuPont ES-A-C200_C200N Features • Extremely Compact Design • 70% Lighter than Traditional Designs • 304 (Schedule 40) Stainless Steel Housing & Sleeve • Groove Fittings Allow Integral Pipeline Adjustment • Patented Tri-Link Check Provides Lowest Pressure Loss • Unmatched Ease of Serviceability • Available with Grooved Butterfly Valve Shutoffs • Available for Horizontal, Vertical or N Pattern Installations • Replaceable Check Disc Rubber The Colt C200, C200N Double Check Valve Assemblies are used to prevent backflow of pollutants, that are objectionable but not toxic, from entering the potable water supply system. The Colt C200, C200N may be installed under continuous pressure service and may be subjected to backpressure. The Colt C200, C200N consists of two independently operating check valves, two shutoff valves, and four test cocks. For use in non-health hazard applications. The Colt C200, C200N features Lead Free* construction to comply with Lead Free* installation requirements. Specifications The Colt C200, C200N Double Check Valve Assembly shall consist of two independent Tri-Link Check modules within a single housing, sleeve access port, four test cocks and two drip tight shutoff valves. Tri-Link Checks shall be removable and serviceable, without the use of special tools. The housing shall be constructed of 304 (Schedule 40) stainless steel pipe with groove end connections. Tri-Link checks shall have reversible elastomer discs and in operation shall produce drip tight closure against the reverse flow of liquid caused by backpressure or backsiphonage. Lead Free* Double Check Valve Assembly shall be constructed using Lead Free* materials. It shall comply with state codes and standards, where applicable, requiring reduced lead content. Assembly shall be a Colt C200, C200N as manufactured by the Ames Company. ColtTM Series C200, C200N Double Check Valve Assemblies Sizes: 21⁄2" – 10" (65 – 250mm) C200N BFG C200 OSY LEAD FREE* * The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Job Name ________________________________________________Contractor ______________________________________________ Job Location ______________________________________________Approval _______________________________________________ Engineer _________________________________________________Contractor’s P.O. No. ______________________________________ Approval _________________________________________________Representative ___________________________________________ Ames Fire & Waterworks product specifications in U.S. customary units and metric are ap prox i mate and are pro vid ed for ref er ence only. For precise mea sure ments, please contact Ames Fire & Waterworks Tech ni cal Ser vice. Ames Fire & Waterworks re serves the right to change or modify prod uct de sign, con struc tion, spec i fi ca tions, or ma te ri als with out prior notice and without in cur ring any ob li ga tion to make such chang es and mod i fi ca tions on Ames Fire & Waterworks prod ucts previously or sub se quent ly sold. NOTICE The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are re-quired to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Size (DN) DimeNSiONS weiGht A C (OSY) C (NRS) D G H I J P C200NRS C200OSY C200N NRS C200N OSY in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. lbs. kgs. lbs. kgs. 21⁄2 65 303⁄4 781 163⁄8 416 93⁄8 238 31⁄2 89 291⁄16 738 211⁄2 546 151⁄2 393 813⁄16 223 93⁄16 234 115 52 125 57 123 56 133 60 3 80 313⁄4 806 187⁄8 479 101⁄4 260 311⁄16 94 301⁄4 768 221⁄4 565 171⁄8 435 93⁄16 233 101⁄2 267 131 59 145 66 144 65 158 72 4 100 333⁄4 857 223⁄4 578 123⁄16 310 4 102 33 838 231⁄2 597 181⁄2 470 915⁄16 252 113⁄16 284 161 73 161 73 184 83 184 83 6 150 431⁄2 1105 301⁄8 765 16 406 51⁄2 140 443⁄4 1137 331⁄4 845 233⁄16 589 131⁄16 332 15 381 273 124 295 134 314 142 336 152 8 200 493⁄4 1264 373⁄4 959 1915⁄16 506 611⁄16 170 541⁄8 1375 401⁄8 1019 277⁄16 697 1511⁄16 399 173⁄16 437 438 199 480 218 513 233 555 252 10 250 573⁄4 1467 453⁄4 1162 2313⁄16 605 83⁄16 208 66 1676 491⁄2 1257 321⁄2 826 175⁄16 440 20 508 721 327 781 354 891 404 951 431 Dimensions — Weights Configurations • Horizontal • Vertical up • “N” pattern horizontal Materials • Housing & Sleeve: 304 (Schedule 40) Stainless Steel • Elastomers: EPDM, Silicone and Buna ‘N’ • Tri-Link Checks: Noryl®, Stainless Steel • Check Discs: Reversible Silicone or EPDM • Test Cocks: Bronze Body Nickel Plated • Pins & Fasteners: 300 Series Stainless Steel • Springs: Stainless Steel Size (DN) DimeNSiONS weiGht A C D G H I J P C200BFG C200NBFG in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 21⁄2 65 273⁄4 705 8 203 31⁄2 89 297⁄8 759 211⁄2 546 1415⁄16 379 813⁄16 223 9 229 56 25 64 29 3 80 281⁄4 718 85⁄16 211 311⁄16 94 3011⁄16 779 221⁄4 565 157⁄16 392 93⁄16 233 91⁄2 241 54 24 67 30 4 100 29 737 815⁄16 227 311⁄16 94 3115⁄16 811 231⁄2 597 161⁄4 412 915⁄16 252 10 254 61 28 84 38 6 150 361⁄2 927 10 254 5 127 433⁄16 1097 331⁄4 845 1911⁄16 500 131⁄16 332 101⁄2 267 117 53 157 71 8 200 423⁄4 1086 121⁄4 311 61⁄2 165 511⁄16 1297 401⁄8 1019 235⁄16 592 1511⁄16 399 143⁄16 361 261 118 337 153 Noryl® is a registered trademark of SABIC Innovative Plastics™. hA iJ G P D C A D C (open) G h J i PC200, C200N C200BFG, C200NBFG Available Models Suffix: NRS - non-rising stem resilient seated gate valves OSY - UL/FM outside stem and yoke, resilient seated gate valves BFG - UL/FM grooved gear operated butterfly valves with tamper switch *OSY FxG - Flanged inlet gate connection and grooved outlet gate connection *OSY GxF - Grooved inlet gate connection and flanged outlet gate connection *OSY GxG - Grooved inlet gate connection and grooved outlet gate connection Available with grooved NRS gate valves - consult factory* Post indicator plate and operating nut available - consult factory* *Consult factory for dimensions Pressure — Temperature Tem per a ture Range: 33°F – 140°F (0.5°C – 60°C) Maximum Working Pres sure: 175psi (12.1 bar) Approvals • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC) For additional approval information please contact the factory or visit our website at www.amesfirewater.com psi 14 12 10 8 6 4 2 0 0 50 100 150 200 250 300 350 gpm 0 190 380 570 760 950 1140 1330 lpm 7.5 15 fps psi 12 10 8 6 4 2 0 psi 12 10 8 6 4 2 0 0 100 200 300 400 500 gpm 0 380 760 1140 1520 1900 lpm 7.5 15 fps 21⁄2" (65mm) 3" (80mm) 0 300 600 900 1200 1500 gpm0 1140 2280 3420 4560 5700 lpm 7.5 12 fps 6" (150mm) 0 100 200 300 400 500 600 700 800 gpm0 380 760 1140 1520 1900 2280 2660 3040 lpm 7.5 13 fps 4" (100mm) psi 12 10 8 6 4 2 0 0 500 1000 1500 2000 2500 3000 3500 gpm 0 1900 3800 5700 7600 9500 11400 13300 lpm 7.5 10 fps 10" (250mm) psi 12 10 8 6 4 2 0 0 500 1000 1500 2000 2500 gpm0 1900 3800 5700 7600 9500 lpm 7.5 10 fps 8" (200mm) psi 24 20 16 12 8 4 0 N VH H N V N VH N VH N HV N HV (**BFG & OSY Only)B64.51015 **** NOTICE Inquire with governing authorities for local installation requirements Capacity UL/FM Certified Flow Characteristics Flow characteristics collected using butterfly shutoff valves. Flow capacity chart identifies valve performance based upon rated water velocity up to 25fps • Service Flow is typically determined by a rated velocity of 7.5fps based upon schedule 40 pipe. • Rated Flow identifies maximum continuous duty perfor-mance determined by AWWA. • UL Flow Rate is 150% of Rated Flow and is not recom- mended for continuous duty. • AWWA Manual M22 [Appendix C] recommends that the maximum water velocity in services be not more than 10fps. *UL Rated Flow *UL Rated Flow Rated Flow Rated Flow Rated Flow Service Flow Service Flow PS i D R O P (* F R i C ti ON L O S S ) PS i D R O P (* F R i C ti ON L O S S ) *UL Rated FlowRated FlowService Flow PS i D R O P (* F R i C ti ON L O S S ) *UL Rated FlowService Flow PS i D R O P (* F R i C ti ON L O S S ) *UL Rated FlowRated FlowService Flow PS i D R O P (* F R i C ti ON L O S S ) *UL Rated FlowRated FlowService Flow PS i D R O P (* F R i C ti ON L O S S ) Horizontal Vertical N - Pattern ES-A-C200C200N 1503 © 2015 Ames Fire & Waterworks USA: Backflow Tel: (978) 689-6066 • Fax: (978) 975-8350 • AmesFireWater.com USA: Control Valves Tel: (713) 943-0688 • Fax: (713) 944-9445 • AmesFireWater.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • AmesFireWater.ca Latin America: Tel: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • AmesFireWater.com A Watts Water Technologies Company victaulic.com 31.80 8826 Rev H Updated 11/2015 © 2015 Victaulic Company. All rights reserved. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. Patented 1.0 PRODUCT DESCRIPTION Available Sizes: • 1 ½ – 8" /40 – 200 mm Pressure Class: • Up to 300 psi/2068 kPa/21 Bar Minimum Air Pressure: • 13 psi/90 kPa/.90 Bar Acutation Options: • Series 776 Low Pressure Actuator • Optional: Series 746-LPA Dry Accelerator Valve Configurations: • Bare • Pre-trimmed: Completely assembled with all necessary trim components. • Vic-Quick Riser: Pre-trimmed and includes: • Shut Off Valve (1 ½"/40 mm: Series 728 Ball Valve, 2" – 8"/50 – 200 mm: Series 705 FireLock Butterfly Valve) • Pre-set high or low air and alarm pressure switches • Drain kit • Fire-Pac Series 745 (refer to Victaulic submittal 30.23) Pipe Preparation: • Victaulic Original Groove System Application/Media: • For use on fire protection systems only. Victaulic® FireLock NXT™ Dry Valve Series 768N 31.80 1 System No.Location Submitted By Date Spec Section Paragraph Approved Date 31.80 8826 Rev H Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 2.0 CERTIFICATION/LISTINGS 104-1a/02 3.0 SPECIFICATIONS - MATERIAL Body: Ductile iron conforming to ASTM A536, grade 65-45-12. Clapper: Aluminum bronze UNS-C95500 Latch: Aluminum bronze UNS-C95500 Shafts: Stainless 17-4 Clapper Seal: Peroxide cured EPDM, ASTM D2000 Bushings/Seat O-rings: Nitrile Springs: Stainless Steel (300 Series) Diaphragm: Peroxide cured EPDM with fabric reinforcement Item Description 1 Valve Body 2 Clapper 3 Clapper Seal 4 Seal Ring 5 Seal Washer 6 Seal Retaining Ring 7 Seal Assembly Bolt 8 Clapper Spring 9 Clapper Shaft 10 Clapper Shaft Bushing and O-Ring (Qty. 2) Item Description 11 Cover Plate 12 Cover Plate Gasket 13 Cover Plate Bolts 14 Latch 15 Latch Spring 16 Latch Spring Bushing and O-Ring (Qty. 2) 17 Diaphragm 18 Diaphragm Cover 19 Diaphragm Cover Cap Screws (Qty. 8) 20 Latch Shaft The 1½-inch/48.3-mm and 2-inch/60.3-mm valve sizes contain washers under the heads of the cover plate bolts. 1 11 16 10 20 19 8 4 3 17 18 7 5 14 15 13 12 2 9 6 16 10 2 victaulic.com 31.80 8826 Rev H Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 3.0 SPECIFICATIONS - MATERIAL (Continued) Standard Trim Package: • Series 776 Low-Pressure Actuator – The Series 776 Low-Pressure Actuator is pneumatically actuated and requires only 13 psi/90 kPa minimum air pressure, regardless of the system supply pressure. This actuator allows the system to operate with a low air or gas pressure of 7 psi/48 kPa. • All required pipe nipples and fittings - standard galvanized finish • All standard trim accessories • All required gauges Optional Trim Package: Black Trim for Foam Systems – If the valve is intended for use in a foam system, black trim must be ordered, per NFPA requirements. Specify this requirement on the order. Optional Accessories: Alarm Pressure Switch – Alarm Pressure Switches are designed to activate electrical alarms and control panels when a sustained flow of water occurs (such as with an open sprinkler). Included in VQR trim. Air Supervisory Pressure Switch – Air Pressure Supervisory Switches are used to monitor low and high system air pressure and are factory pre-set. Included in VQR trim. Series 746-LPA Dry Accelerator – The Series 746-LPA Dry Accelerator is required when the Series 768N Dry Valve is installed in large systems to improve response time. Refer to Victaulic submittal 30.64. Series 760 Water Motor Alarm – The Series 760 Water Motor Alarm is a mechanical device that sounds when a sustained flow of water occurs (such as with an open sprinkler). Refer to Victaulic submittal 30.32. Series 75B Supplemental Alarm Device – The Series 75B Supplemental Alarm Device is designed to provide a continuous alarm for systems equipped with a mechanical device. Refer to Victaulic submittal 30.33. Series 75D Water Column Kit – The Series 75D Water Column Kit is designed to minimize residual water in the riser from collecting above the clapper. Refer to Victaulic submittal 30.34. Air Supply System – The air supply system contains all components for establishing and maintaining air in the system. The compressor, low-pressure alarms, ball valves, and required trim are included in the air supply system. Air Compressor (See page 6 for more on the Victaulic Series 7C7 Compressor Package) Air Maintenance Trim Assembly Fire Alarm Control Panels Drain Connection Kit – Included in VQR option. Orange shaded areas identify components that are optional equipment. These components are standard when the VQR assembly is ordered. Gray shaded areas identify components that are optional equipment. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 3 victaulic.com 31.80 8826 Rev H Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 4.0 DIMENSIONS Nominal Size Dimensions Weight Each A A1 B B1 B2 C D D1 E F F1 G H J K L Without Trim With Trim inches DN inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm lbs kg lbs kg 1 ½ DN40 9.00 16.37 27.75 32.25 46.00 10.25 13.00 16.25 9.00 10.00 5.50 27.25 3.25 10.25 6.00 8.25 16.7 43.0228.60 415.80 705 819 1168 260 330 413 229 254 140 692 83 260 152 210 7.6 19.52 DN50 9.00 13.83 27.75 32.25 46.00 10.00 13.00 16.50 9.00 10.00 6.75 27.00 3.25 10.25 6.00 8.75 17.0 43.0228.60 351.28 705 819 1168 254 330 419 229 254 171 686 83 260 152 222 7.7 19.52 ½ 12.61 16.51 29.50 34.25 47.75 12.50 14.00 18.00 9.50 10.00 8.00 25.50 4.00 9.75 6.50 6.75 41.0 65.0320.29 419.35 749 870 1213 318 356 457 241 254 203 648 102 248 165 171 18.7 29.5 76.1 mm 12.61 16.51 29.50 34.25 47.75 12.50 14.00 18.00 9.50 10.00 8.00 25.50 4.00 9.75 6.50 6.75 41.0 65.0320.29 419.35 749 870 1213 318 356 457 241 254 203 648 102 248 165 171 18.7 29.53 DN80 12.61 16.51 29.50 34.25 47.75 12.50 14.00 18.00 9.50 10.00 8.00 25.50 4.00 9.75 6.50 6.75 41.0 66.0320.29 419.35 749 870 1213 318 356 457 241 254 203 648 102 248 165 171 18.7 29.94 DN100 15.03 19.85 30.25 34.75 48.25 15.00 16.00 22.00 11.00 11.25 9.25 25.25 4.75 8.50 8.00 7.00 59.0 95.0381.76 504.19 768 883 1226 381 406 559 279 286 235 641 121 216 203 178 26.7 43.0 165.1 mm 16.00 22.13 31.25 35.75 50.25 15.25 17.00 28.75 11.00 11.75 11.75 25.50 4.50 8.25 8.25 7.25 80.0 116.0406.40 562.10 794 908 1276 387 432 730 279 298 298 648 114 210 210 184 36.2 52.66 DN150 16.00 22.13 31.25 35.75 50.25 15.25 17.00 28.75 11.00 11.75 11.75 25.50 4.50 8.25 8.25 7.25 80.0 116.0406.40 562.10 794 908 1276 387 432 730 279 298 298 648 114 210 210 184 36.2 52.68 DN200 17.50 23.02 33.00 37.75 51.25 16.25 16.25 25.25 12.25 10.00 13.75 26.00 4.75 8.25 9.25 7.75 122.0 158.0444.50 584.71 838 959 1302 413 413 641 311 254 349 660 121 210 235 197 55.3 71.6 NOTES • The “A” dimension is the actual takeout dimension of the valve body. • The “A1” dimension is the actual takeout dimension of the valve body with water supply main control valve. • The “D1” dimension is not a fixed measurement. The drip cup can be rotated to provide more clearance at the back of the trim. • Components shown as dotted lines denote optional equipment. • The recommended drain connection kit (shown in orange) is for reference and takeout dimensions. This drain connection comes standard when the VQR assembly is ordered. H CFull Open K E A A1 B2 G B J F D D1 F1 L B1 4 victaulic.com 31.80 8826 Rev H Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE Hydraulic Friction Loss The chart below expresses the flow of water at 65ºF/18ºC through an open valve. P R E S S U R E D R O P – P S I FLOW RATE – GPM 800 3,000 8,000 6.05.04.0 3.0 2.0 1.00.90.80.70.60.50.4 0.3 0.2 0.1 10 20 30 40 60 80 100 200 300 400 600 1,000 2,000 4,000 6,000 10,000 20,000 3"/80 m m 4"/10 0 m m 6"/15 0 m m a n d 1 6 5 . 1 m m 8"/2 0 0 m m 2½"/6 5 m m a n d 7 6 . 1 m m 1½" / 4 0 m m 2"/50 m m Frictional Resistance The chart below expresses the frictional resistance of Victaulic Series 768N FireLock NXT. Dry Valve in equivalent feet of straight pipe. CV Values: CV values for flow of water at +60°F/+16°C through a fully open valve are shown in the table below. Nominal Size Actual Outside Diameter Equivalent Length of Pipe inches DN inches mm feet meters 1 ½1.900 3.00DN4048.3 0.914 2 2.375 9.00DN5060.3 2.743 2 ½2.875 8.0073.0 2.438 76.1 mm 3.000 8.0076.1 2.439 3 3.500 17.00DN8088.9 5.182 4 4.500 21.00DN100114.3 6.401 165.1 mm 6.500 22.00165.1 6.706 6 6.625 22.00DN150168.3 6.706 8 8.625 50.00DN200219.1 15.240 Valve Size Full Open Nominal Size Actual Outside Diameter Flow Coefficient inches mm inches mm Cv Kv 1 ½1.900 60 40 48.3 52.0 2 2.375 110 50 60.3 95.0 2 ½2.875 180 65 73.0 156.0 76.1 mm 3.000 180 76.1 156.0 3 3.500 200 80 88.9 173.0 4 4.500 350 100 114.3 302.8 165.1 mm 6.500 1000 165.1 865.0 6 6.625 1000 150 168.3 865.0 8 8.625 1500 200 219.1 1499.1 Formulas for CV values ΔP = Q2/CV2 Q = CV × √ΔP Flow Coefficient Cv Q (Flow)GPM ΔP (Pressure Drop)psi Where: 5 victaulic.com 31.80 8826 Rev H Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE (Continued) Air Supply Requirements • Minimum: 13 psi/90 kPA/.9 Bar regardless of the system water pressure • Maximum Recommended: 18 psi/124 kPa/1.24 Bar • Multiple Series 768N FireLock NXT Dry Valves with a common air supply: • Isolate systems with a Victaulic spring –loaded, soft-seated ball check valve to ensure air integrity and serviceability of each system. • Sizing the compressor: • Engineer/system designer is responsible • Entire system must be charged to the required air pressure within 30 minutes to meet NFPA requirements • An oversized compressor will slow down or possibly prevent valve operation • Compressor filling the system too fast: • May be necessary to restrict the air supply • Ensure that air exhausted from an open sprinkler or manual release valve is not replaced by the air supply system as fast as it is exhausted • Compressor Requirements • Base or Riser Mounted Compressors: • “On” or “low” pressure setting: 13 psi/90 kPA/.9 Bar • “Off” or “high” pressure setting: 18 psi/124 kPa/1.24 Bar • Victaulic Series 7C7 riser mounted and pre-set for pressure requirements (refer to Victaulic submittal 30.22). • If the compressor is not equipped with a pressure switch, the Series 757P Air Maintenance Trim Assembly with pressure switch should be installed (refer to Victaulic submittal 30.36). • Shop Air or Tank-Mounted Air Compressors: • Series 757 Regulated Air Maintenance Trim Assembly should be installed (refer to Victaulic submittal 30.35) • 13 psi/90 kPA/.9 Bar should be used as the set point for the air regulator • The compressor cut-in (turn-on) pressure setting should be at least 5 psi/34kPa/34 Bar above the set point of the air regulator. • Exploded View Trim: Series 757 Regulated Air Maintenance Trim Assembly (refer to Victaulic submittal 30.35) • Compressor Requirements and settings for systems installed with series 746 or series 746-LPA dry accelerators • A tank-mounted air compressor with a Series 757 Regulated AMTA must be used to supply air to system installed with a Series 746 or Series 746-LPA Dry Accelerator. • In the event a compressor becomes inoperative, a properly sized tank-mounted air compressor provides the greatest protection, since air can be supplied continuously to the sprinkler system for an extended time period. 6 victaulic.com 31.80 8826 Rev H Updated 11/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com User Responsibility for Product Selection and SuitabilityEach user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms “Patented” or “Patent Pending” refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. NoteThis product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. TrademarksVictaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 6.0 NOTIFICATIONS WARNING • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS 30.35: FireLock™ Air Maintenance Trim Assembly Series 757 Submittal 30.36: FireLock™ Air Maintenance Trim Assembly Series 757P Submittal 30.22: FireLock® Compressor Package Series 7C7 Submittal 30.32: FireLock™ Water Motor Alarm Series 760 Submittal 30.65: FireLock™ Low Pressure Actuator Series 776 Submittal I-768N: FireLock NXT™ Dry Valve Series 768N Installation Manual 7 victaulic.com