Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00526 - Season's II Medical OfficePermit Inspection Summary Permit Status of (Expired) as of Report Date: 02/20/2018 12:38 pm Permit Details Permit Number: 13-00526 Season's II Medical Office 36 South Professional Plaza Building - Commercial Permit Issued Date: 06/23/2014 Permit Inspection Statistics 46Total Inspections Completed: 35Total Inspections Passed: Inspection Pass Rate 76.09% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 05/21/2014PassTed DyeFooting Inspection 05/30/2014PassTed DyeFoundation Inspection Inspection for pour from grid lines 3 through 6 and A through J All rebar looked good. Inspector Comments: 06/10/2014PassQuinton OwensFoundation Inspection West end of south wall & stairwell & west wall almost to parking entrance.Inspector Comments: 06/19/2014PassTed DyeFooting Inspection 07/17/2014PassQuinton OwensFoundation Inspection Finished previous day's inspection and arrived after pour started. Remaining footing for parking canopy appeared properly placed. Special inspector on site said it all was good. Inspector Comments: 07/23/2014PassQuinton OwensFoundation Inspection Peir foundations at exterior parking. Rebar installed per plans.Inspector Comments: 07/23/2014PassQuinton OwensCommercial Footing Inspection Footing on north side of pool location. Rebar as per plans.Inspector Comments: 09/25/2014PassQuinton OwensCommercial Framing/Structure Inspection Concealed locations to be covered only. No rough-in work done. Not ready for full framing inspection. Inspector Comments: 10/22/2014PassQuinton OwensSheeting Only South section of roof sheathing inspected.Inspector Comments: 10/29/2014PassQuinton OwensSheeting Added missed nailing while doing inspection. All exterior sheathing ok to cover.Inspector Comments: 10/30/2014PassQuinton OwensSheeting Middle and North section of roof sheathing inspected.Inspector Comments: 12/11/2014PassQuinton OwensCommercial Framing/Structure Inspection Hold down inspection only.Inspector Comments: 01/06/2015FailQuinton OwensCommercial Insulation Inspection Parking garage insulation incomplete at plumbing pipes near center of building. Call back when plumbing passes inspection and insulation is installed. Inspector Comments: Page 1 of 4 (Continued) Permit Details Permit Number: 13-00526 Season's II Medical Office 36 South Professional Plaza Building - Commercial Permit Status of (Expired) as of Report Date: 02/20/2018 12:38 pm Permit Inspection Summary 01/16/2015PassQuinton OwensCommercial Insulation Inspection seal 2nd level window on east side above stairs.Inspector Comments: 01/26/2015PassQuinton OwensCommercial Sheetrock/Drywall Inspection One line of screws on one sheet missing in west bathroom upstairs, and a few spots in west stairwell. Fasten as required. Inspector Comments: 02/11/2015FailTed DyeCommercial Sheetrock/Drywall Inspection 02/12/2015PassQuinton OwensCommercial Insulation Inspection Insulation in floor overhang over parking on West side. Double layer of what seems to be R-19 batts (cannot read labeling on insulation). Inspector Comments: 05/22/2015FailQuinton OwensCommercial Building Final Window by west stairs is not labeled as tempered. South wall to be fire rated from the inside (both levels). Handrail on wall at bottom of west stairs is missing. Exterior handrails are not installed. All penetrations and perimeter of ceiling in parking area under building must be fire rated. Fire rate framed wall on east side parking area and penetrations above area behind wall. Exterior work still in progress. Inspector Comments: 07/23/2015FailQuinton OwensCommercial Building Final Windows tempered as required (window by west stairs added "armorcoat" to glazing). Several penetrations not rated on ceiling of garage and orange foam is not fire rated. Handrails are not completed yet. Warning sign/bar not installed at garage entry yet. South wall on will not have to be fire rated on the inside until tenant finish is done. Building identification numbers installed? Inspector Comments: 07/31/2015FailQuinton OwensCommercial Building Final Handrails down to parking garage not completed. Waiting on fire collars needed at plastic pipe boxed cover on west wall. Large drain pipe goes through rated wall or place damper in ceiling fan (unless fan housing and duct is all metal) - where is outlet. Post address numbers (temp #'s ok), Post restrom signage (temp signs ok for now) - also needed on tenant ADA restroom. Inspector Comments: 08/14/2015FailQuinton OwensCommercial Building Final Handrails down to parking garage not completed on exterior stairs. ADA restroom signs are required (temp signs will be ok until additional tenant spaces are finished). Inspector Comments: 09/23/2015PassQuinton OwensCommercial Building Final ADA restroom signs are required (temp signs will be ok until additional tenant spaces are finished). One hour fire rating on south wall to be done with tenant finish. Inspector Comments: Page 2 of 4 (Continued) Permit Details Permit Number: 13-00526 Season's II Medical Office 36 South Professional Plaza Building - Commercial Permit Status of (Expired) as of Report Date: 02/20/2018 12:38 pm Permit Inspection Summary Electrical Inspection Type 12/11/2014PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in 01/20/2015PassBret StoddardCommercial Electrical Rough-in 02/10/2015PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in 02/10/2015PassBret StoddardCOM & MFR Electrical Service Inspection 02/18/2015PassBret StoddardCOM & MFR Electrical Service Inspection 02/25/2015PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in 02/26/2015PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in Fire Inspection Type 12/24/2014FailDale PickeringFire Sprinkler Rough-in 12/24/2014FailDale PickeringFire Sprinkler Rough-in 01/09/2015PassDale PickeringFire Sprinkler Rough-in Heads missing on the ends of branch lines, on order, will be installed for next rough-in inspection. DD Inspector Comments: 02/09/2015PassDale PickeringFire Sprinkler Rough-in Rough-in inspection for attic dry system only. DPInspector Comments: 05/05/2015PassDale PickeringFire Sprinkler Hydro 05/06/2015FailBret StoddardFire Alarm Final Inspection 05/06/2015PassDale PickeringFire Sprinkler Final Inspection Page 3 of 4 (Continued) Permit Details Permit Number: 13-00526 Season's II Medical Office 36 South Professional Plaza Building - Commercial Permit Status of (Expired) as of Report Date: 02/20/2018 12:38 pm Permit Inspection Summary Mechanical Inspection Type 12/22/2014PassDon AllenHVAC Rough-in looked at the duct in the attic and presser test on the snow melt both look goodInspector Comments: 01/07/2015PassDon AllenGas Pressure Test gas presser held at 60lbInspector Comments: 01/15/2015PassDon AllenHVAC Rough-in All the duck in the ceiling lookd goodInspector Comments: 02/03/2015PassDon AllenHVAC Rough-in looked at the duct in the hall ways they are all good to cover.Inspector Comments: 04/28/2015FailDon AllenHVAC Final Inspection Mech. units in the hall way would not turn on. Call for reinspectInspector Comments: 05/21/2015PassDon AllenHVAC Final Inspection the main hallways on the 1 and 2 floor are good for the c/oInspector Comments: 07/30/2015PassDon AllenHVAC Final Inspection GOOD FOR THE C/OInspector Comments: Plumbing Inspection Type 01/07/2015PassDon AllenPlumbing Rough-in All the plumbing in the parking garage ceiling looks goodInspector Comments: 02/26/2015PassDon AllenPlumbing Rough-in water line held at 100 lb. good to coverInspector Comments: 05/06/2015PassDon AllenPlumbing Final Inspection Inspections Required Commercial Sheetrock/Drywall Inspection Commercial Sheetrock/Drywall Inspection Fire Alarm Final Inspection Page 4 of 4