Loading...
HomeMy WebLinkAboutINVERTER INFO - 17-00745 - 621 Eaglewood Dr - Solar PanelSolarEdge Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US IN V E R T E R S www.solaredge.usUSA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRICA-BULGARIA Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Integrated Arc Fault protection and Rapid Shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring Outdoor and indoor installation Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) 12-25 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2017. V.01. Subject to change without notice. Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US OUTPUT  Rated AC Power Output 3000 3800 5000 6000 7600 VA Max. AC Power Output 3000 3800 5000 6000 7600 VA AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) --3 --Vac AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264) 3 3 3 3 3 Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current 208V --24 --A Maximum Continuous Output Current 240V 12.5 16 21 25 32 A GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT  Maximum DC Power 4650 5900 7750 9300 11800 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V --15.5 --Adc Maximum Input Current 240V 8.5 10.5 13.5 16.5 20 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(2) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21(3), Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS  AC Output Conduit Size / AWG Range 0.75-1” Conduit / 14-6 AWG DC Input Conduit Size / # of Strings / AWG Range 0.75-1” Conduit /1-2 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 in / mm Weight with Safety Switch 25.3 / 11.5 lb / kg Noise < 25 dBA Cooling Natural Convection Operating Temperature Range -13 to +140 / -25 to +60(4) (-40˚F / -40˚C option)(5)˚F / ˚C Protection Rating NEMA 3R (Inverter with Safety Switch) (1) For other regional settings please contact SolarEdge support (2) Revenue grade inverter P/N: SExxxxH-US000NNC2(3) Pending certification(4) Power de-rating from 50˚C(5) -40 version P/N: SExxxxH-US000NNU4 PO W E R O P T I M I Z E R SolarEdge Power Optimizer Module Add-On P300 / P350 / P404 / P405 / P500 PV power optimization at the module-level Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of modules mismatch-loss, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module level monitoring Module-level voltage shutdown for installer and firefighter safety www.solaredge.comUSA - CANADA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2015. V.01. Subject to change without notice. P300 (for 60-cell modules) P350 (for high-power 60-cell and for 72-cell modules) P500 (for 96-cell modules) P404 (for 60-cell and 72-cell, short strings) P405 (for thin film modules) INPUT Rated Input DC Power(1)300 350 500 405 405 W Absolute Maximum Input Voltage (Voc at lowest temperature)48 60 80 80 125 Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 12.5 - 80 12.5 - 105 Vdc Maximum Continuous Input Current (Isc)10 11 10.1 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 128 x 152 x 27.5 / 5 x 5.97 x 1.08 128 x 152 x 35 / 5 x 5.97 x 1.37 128 x 152 x 43 / 5 x 5.97 x 1.69 128 x 152 x 50 / 5 x 5.97 x 1.96 mm / in Weight (including cables) 760 / 1.7 830 / 1.8 994 / 2.1 1064 / 2.3 gr / lb Input Connector MC4(2) Output Connector MC4 Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ft Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % SolarEdge Power Optimizer Module Add-On P300 / P350 / P404 / P405 / P500 (1) Rated STC power of the module. Module of up to +5% power tolerance allowed. (2) For other connector types please contact SolarEdge. PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(3)SINGLE PHASE THREE PHASE Minimum String Length (Power Optimizers) P300,P350,P500 8 16 P404,P405 6 13 Maximum String Length (Power Optimizers)25 50 Maximum Power per String 5250 11250 W Parallel Strings of Different Lengths or Orientations Yes (3) It is not allowed to mix P404/P405 with P300/P350/P500/P600/P700 in one string.