Mechanical Inspection Type
08/02/2017FailDon AllenHVAC Rough-in
08/15/2017PassDon AllenHVAC Rough-in
11/15/2017FailQuinton OwensHVAC Final Inspection
The following corrections are needed for approval-call for re-inspection:
* Dryer vent termination covered (install proper dryer termination).
* Combustion intake protective cover or elbow needed on top of furnace (see
installation manual)
* Terminate furnace exhaust with elbow turned down or other approved method
per installation manual)
* furnace installation manual not found during inspection.
Wood stove vent does not have termination cap on and does not have clearance
to drywall. Wood stove is not planned for installation at this time (maybe in a
year - pull permit for inspections and approval)
Inspector Comments:
11/17/2017FailDon AllenHVAC Final Inspection
NEED TO INSTALL PLUGS IN TO THE GAS VALVES FOR APPLIANCESInspector Comments:
11/20/2017PassDon AllenHVAC Final Inspection