HomeMy WebLinkAboutINSPECTION SUMMARY REPORT - 16-00629 - Sawtelle Apts. - Sawtelle Apts - 18 Plex #2Permit Inspection Summary Permit Status of (Open) as of Report Date: 11/13/2017 12:29 pm Permit Details Permit Number: 16-00629 Sawtelle Apts - 18 Plex #2 146 N 1st W Multi-Family Residential Permit Issued Date: 10/24/2016 Permit Inspection Statistics 33Total Inspections Completed: 22Total Inspections Passed: Inspection Pass Rate 66.67% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 10/12/2016PassTed DyeCommercial Footing Inspection 10/19/2016PassTed DyeFoundation Inspection 10/24/2016FailTed DyeCommercial Insulation Inspection 11/01/2016PassTed DyeCommercial Insulation Inspection 01/13/2017PassQuinton OwensSheeting Exterior sheeting. Be careful of penetrating into sheathing. Fasteners should not penetrate surface. Use nails if needed. Inspector Comments: 03/17/2017PARTPASSTed DyeCommercial Framing/Structure Inspection Ok to insulate floors and exterior walls Trusses will need to be checked for lateral bracing and hip truss hanger diagonal nailing. Inspector Comments: 03/22/2017PassTed DyeCommercial Framing/Structure Inspection 03/22/2017PARTPASSTed DyeCommercial Insulation Inspection 03/24/2017PARTPASSTed DyeCommercial Insulation Inspection Inspection of the 2 separation wall in the center units on levels 2 and 3Inspector Comments: 03/27/2017PassTed DyeCommercial Insulation Inspection * Tape rest of gap in corner behind tub in west side middle unit on 3rd floor. * Fire rating behind tub is incomplete in middle unit east side on 2nd floor. * Fire rate ceiling penetration behind tub in middle unit east side on 1st floor. * Fire rate sprinkler penetrations and tape joints to be covered with future soffit. (use fire caulk not mineral wool insulation) * Fire caulk shower penetration in front west unit on 1st floor. Inspector Comments: 03/28/2017PARTPASSQuinton OwensResidential Sheetrock/Drywall Inspection Other areas approved for taping.Inspector Comments: 03/28/2017PassQuinton OwensCommercial Framing/Structure Inspection Framing in egress corridorInspector Comments: 4/4 Re-inspection item: Fire sprinkler penetrations not caulked (early morning & late afternoon) Inspector Comments: 4/6: Fire sprinkler penetrations not caulked (checked with storage bldg framing) Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 16-00629 Sawtelle Apts - 18 Plex #2 146 N 1st W Multi-Family Residential Permit Status of (Open) as of Report Date: 11/13/2017 12:29 pm Permit Inspection Summary 04/07/2017PassQuinton OwensCommercial Framing/Structure Inspection 4/7: Fire sprinkler penetrations caulked and approved for cover (checked by Ted) Inspector Comments: 06/09/2017FailQuinton OwensCommercial Building Final 07/14/2017FailQuinton OwensCommercial Building Final 10/25/2017PassQuinton OwensCommercial Building Final Electrical Inspection Type 03/16/2017PassBret StoddardCOM & MFR Electrical Service Inspection 03/16/2017PassBret StoddardResidential Electrical Rough-in 06/12/2017FailBret StoddardCommerical Electrical Final Inspection 06/15/2017PassBret StoddardCommerical Electrical Final Inspection Fire Inspection Type 05/24/2017PassDale PickeringFire Sprinkler Hydro 06/13/2017FailDavid DavisFire Sprinkler Final Inspection 06/15/2017PassBret StoddardFire Alarm Final Inspection 06/15/2017PassDavid DavisFire Department Final Inspection 06/15/2017PassDale PickeringFire Sprinkler Final Inspection 06/15/2017PassDale PickeringFire Sprinkler Rough-in 10/25/2017PassTawnya GroverFire Underground Inspection Mechanical Inspection Type 02/21/2017PassDon AllenGas Pressure Test 03/16/2017PassDon AllenHVAC Rough-in 06/09/2017FailDon AllenHVAC Final Inspection Exhaust fans in the top middle apt. bathroom does not workInspector Comments: 07/17/2017PassDon AllenHVAC Final Inspection Correction done: Bathroom fan working (needed to be plugged in)Inspector Comments: Plumbing Inspection Type 03/07/2017PassDon AllenPlumbing Rough-in 06/09/2017FailDon AllenPlumbing Final Inspection Need to finish turning on the water to the apt.Inspector Comments: 10/25/2017PassDon AllenPlumbing Final Inspection Approved per discussion with DonInspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 16-00629 Sawtelle Apts - 18 Plex #2 146 N 1st W Multi-Family Residential Permit Status of (Open) as of Report Date: 11/13/2017 12:29 pm Permit Inspection Summary Page 3 of 3