HomeMy WebLinkAboutRESCHECK - 17-00701 - 1204 Franklin Dr - New SFRfZGenerated by REScheck-Web Software
Compliance Certificate
Project Adalynn Plan
Energy Code:
2012 IECC
50.0
Location:
Rexburg, Idaho
62
Construction Type:
Single-family
19.0
Project Type:
New Construction
101
Conditioned Floor Area:
4,798 ft2
Glazing Area
14%
16
Climate Zone:
6 (8693 HDD)
Permit Date:
0.270
17
Permit Number:
278
Construction Site:
Owner/Agent:
Designer/Contractor:
Floor: All -Wood Joist[Truss
2,399
Justin Stevens
3.0
0.041
Stevens Homes
Basement: Solid Concrete or Masonry
1,420
PO Box 2759
0.0
0.041
Idaho Falls, Idaho 83403
Wall height: 9.0'
justin@stevenshomes.com
Compliance: Posses using UA trade-off
Compliance: 2.3% Better Than Code Maximum UA: 477 Your UA: 466
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off roles.
It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home.
Envelope Assemblies
Ceiling: Flat or Scissor Truss
2,399
50.0
0.0
0.026
62
Wall: Wood Frame, 161n. D.C.
2,412
19.0
3.0
0.050
101
Door: Solid
42
0.390
16
Glass Door: Glass
63
0.270
17
Window: Vinyl Frame, 2 Pane w/ Low -E
278
0.270
75
Floor: All -Wood Joist[Truss
2,399
19.0
3.0
0.041
98
Basement: Solid Concrete or Masonry
1,420
19.0
0.0
0.041
58
Wall height: 9.0'
Depth below grade: 8.9'
Insulation depth: 9.0'
Basement: Wood Frame
913
19.0
0.0
0.043
39
Wall height: 9.0'
Depth below grade: 8.9'
Insulation depth: 9.0'
Project Title: Adalynn Plan Report date: 11/07/17
Data filename: Page 1 of 9
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
��/7/
Date
Project Notes:
Adalynn Plan
Project Title: Adalynn Plan Report date: 11/07/17
Data filename: Page 2 of 5
fZREScheck Software Version : REScheck-Web
Inspection Checklist
Energy Code: 2012 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
�ecnon Plans Verified Field Verified
# Pre-inspection/Plan Review
& Re .ID Value Value
103.1, Construction drawings and
103.2 documentation demonstrate
[PR1]1 energy code compliance for the
building envelope.
Complies?
❑Does Not
❑Not Observable
Comments/Assumptions
103.1,
.Construction drawings and❑Complies
,
103.2,
documentation demonstrate❑Does
Not
403.7
[PR3]1
energy code compliance for❑Not
lighting and mechanical systems.
Observable
,V
Systems serving multiple❑Not
Applicable j
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1,
Heating and cooling equipment is:, Heating:
Heating:
❑Complies
403.6
sized per ACCA Manual S based Btu/hr
I Btu/hr❑Does
Not
[PR2]'
on loads calculated per ACCA Cooling:
Cooling:
❑Not Observable
19)
Manual J or other methods Btu/hr
approved by the code official.
Btu/hr_
j❑Not Applicable
Additional Comments/Assumptions:
1 JHgh Impact (Tier 1) u ... Medium Impact (Tier 2) ', Low Impact (Tier 3)
Project Title: Adalynn Plan Report date: 11/07/17
Data filename: Page 3 of 9
Section
#
Foundation Inspection
Plans Verified
Value
Field Verified
Value
Complies? Comments/Assumptions
402.1.1
Conditioned basement wall
R-_
R -❑Complies
'See the Envelope Assemblies
[FO4]1
insulation R -value. Where interiorR-
!. R_
j❑Does Not ; table for values.
insulation is used, verification
j❑Not Observable;
may need to occur during
❑Not Applicable j
Insulation Inspection. Not
required in warm -humid locations
in Climate Zone 3.
303.2
[FO511
Conditioned basement wall
insulation installed per
c
❑Complies
❑Does
x
Not
manufacturer's instructions
e ,
[]Not Observable
❑Not Applicable
402.2.8
Conditioned basement wall
ft
ft
;❑Complies See the Envelope Assemblies
[FO611
insulation depth of burial orj❑Does
Not ;table for values.
distance from top of wall,❑Not
Observable
❑Not Applicable
303.2.1
A protective covering is installed
- ` ❑Complies
[FO11]2
to protect exposed exterior
❑Does Not
U
insulation and extends a
F :`
'`.�
."-
-
"❑Not Observable
minimum of 6 in. below grade
_ -
❑Not Applicable j
403.8
Snow- and Ice -melting system'
r-
❑Complies
[FO12]2 _controls
installed.`.
<a
€..]❑Does Not
❑Not Observable
❑Not Applicable j
Additional Comments/Assumptions:
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) JA�J Low Impact (Tier 3)
Project Title: Adalynn Plan Report date: 11/07/17
Data filename: Page 4 of 9
Section
#
Framing /Rough -In Inspection
I I
Plans Verifled
Value
Field Verified
Value
complies?
Comments/Assumptions
& Re .ID
402.1.1,
(Door U -factor.
U-_ U -_❑Complies
See the Envelope Assemblies
402.3.4❑Does
-
Not table for values.
[FR1]1
j❑Not Observable
❑Not Applicable j
402.1.1,
Glazing U -tactor (area -weighted '..
U -_I. U -_❑Complies
;See the Envelope Assemblies
402.3.1,
average).
j❑Does Not ; table for values.
402.3.3,
402.3.6,❑Not
Observable
402.5
;❑Not Applicable
[FR211
303.1.3
Iare
U -factors of fenestration productsg ,-a r ..
❑Complies
[FR4]1
determined in accordance
... _, < ;,,..fl, -
-�
[]Does Not
,with
'taken
the NFRC test procedure or
]•,'❑Not
Observable
from the default table.
>❑Not
Applicable
402.4.1.1
Air barrier and thermal barrier :
❑Complies
[FR23]1
installed per manufacturer's.❑Does
Not
instructions.
❑Not Observable
j❑Not
Applicable j
402.4.3
Fenestration that is not site built
;❑Complies
[FR20]1
is listed and labeled as meeting
-.
'❑Does
Not
AAMA /WDMA/CSA 101/I.S.2/A440
;❑Not
Observable
or has infiltration rates per NFRC
400 that do not exceed code
❑Not Applicable
limits.
402.4.4
IC -rated recessed lighting fixtures,
❑Complies
[FR16]2
sealed at housing/interior finish
❑Does Not
and labeled to indicate <2.0 cfm
leakage at 75 Pa.
'[]Not
Observable
❑Not Applicable j
403.2.1
Supply ducts in attics are
R- R -❑Complies
[FR12]1
insulated to zR-8. All other ducts
R- R -❑Does
Not
in unconditioned spaces or j
outside the building envelope are :
;❑Not
Observable
insulated to >_R-6.
;❑Not
Applicable
403.2.2
All joints and seams of air ducts,IME]Not
❑Complies
[FR13]1
air handlers, and filter boxes are❑Does
Not
sealed.
❑Not Observable
❑Not Applicable
403.2.3
Building cavities are not used as❑Complies
[FR15]3
ducts or plenums.
❑Does Not
❑Not Observable
Applicable:
403.3 .HVAC
piping conveying fluids IR-_
R -_❑Complies
[FR17]2 -above
105 QF or chilled fluids
❑Does Not i
4
below 55 QF are insulated to ?R- j
I❑Not
Observable
3
j❑Not
Applicable
403.3.1
Protection of Insulation on HVAC -
- �'- ' - - - -
❑Complies
[FR24]1
piping ,,-.;;,
' -
❑Does Not
'
❑Not Observable
_
❑Not Applicable
403.4.2
Hot water pipes are insulated to
R-_ R -❑Complies
[FR18]2
>_R-3.❑Does
Not
U
;❑Not Observable
❑Not Applicable
11 High Impact (Tier 1) MM Medium Impact (Tier 2) ;3; Low Impact (Tier 3)
Project Title: Adalynn Plan Report date: 11/07/17
Data filename: Page 5 of 9
+� # Framing / Rough -in Inspection Plans Verified Field Verif led
& Req.ID VValue
Complies? Comments/Assumptions
alue
403.5 Automatic or gravity dampers are, i❑Complies
[FR19]2 installed on all outdoor air❑Does Not
intakes and exhausts. 1
i❑Not Observable I
❑Not Applicable j
Additional Comments/Assumptions:
11 High Impact (Tier 1) rry',' Medium Impact (Tier 2) 13 lLow Impact (Tier 3)
Project Title: Adalynn Plan Report date: 11/07/17
Data filename: Page 6 of 9
section
#
Insulation Inspection
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req.ID
-
303.1 -'All
installed insulation is labeled
❑Complies
[IN13]2 l'or the installed R-values
',.❑Does Not '
'
V �
provided.
��
,❑Not Observable I
'!
!❑Not Applicable j
402.1.1,
(Floor insulation R-value.
R-
R-
I❑Complies See the Envelope Assemblies
402.2.6
❑ Wood
❑ Wood
i❑Does Not table for values.
[IN111
❑ Steel
❑ Steel❑Not
Observable
❑Not Applicable
303.2,
Floor insulation installed per
-,❑Complies
402.2.7
manufacturer's Instructions, and
❑Does Not
[IN211
in substantial contact with the
_
Observable
underside of the subfloor.
-
.:,_❑Not
Applicable
_''Jj❑Not
402.1.1,
Wall insulation R-value. If this is a
R-
R-
.❑Complies See the Envelope Assemblies
402.2.5,
mass wall with at least 1/z of the
❑ Woodj
❑Wood
-❑Does Not table for values.
402.2.6
wall Insulation on the wall
❑ Mass
❑ Mass '❑Not
Observable
[IN311
exterior, the exterior insulation
requirement applies (FR10).
j ❑Steel
Steel
❑❑Not
Applicable
t3,
303.2
Wall insulation is installed per
:
!❑Complies
[IN411
manufacturer's instructions.
❑Does Not
❑Not Observable
rj❑Not
Applicable j
Additional Comments/Assumptions:
11 High Impact (Tier 1) ,.'. Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Adalynn Plan Report date: 11/07/17
Data filename: Page 7 of 9
Section
#
Final Inspection Provisions
Plans Verified Field Verified
Value Value
Complies?
Comments/Assumptions
& Re .ID
402.1.1,
Ceiling insulation R -value.
R- ; R -❑Complies
See the Envelope Assemblies
402.2.1,
❑ Wood ❑ Wood
❑Does Not table for values.
402.2.2,
402.2.6
❑ Steel ❑ Steel
❑ Not Observable
[Fill'
❑Not Applicable
303.1.1.1,
Ceiling insulation Installed per
❑Complies
303.2
manufacturer's instructions.
NNW,
❑Does Not
[FI211
Blown insulation marked every
f Yn,.10) '
Observable
300 ftz.❑Not
UNot Applicable
402.2.3
Vented attics with air permeable'.❑Complies
[F122 ]2
insulation include baffle adjacent
❑Does Not
to soffit and eave vents that
Observable I
extends over insulation.❑Not
❑Not Applicable
402.2.4
Attic access hatch and door
R- R -_❑Complies
[FI311
insulation >_R -value of the
:,❑Does
Not
10)
adjacent assembly.
I❑Not
Observable
_
;❑Not
Applicable
402.4.1.2
Blower door test @ 50 Pa. <=5
ACH 50 =_ ACH 50 =_ ;❑Complies
[FI1711
ach in Climate Zones 1-2, and
;❑Does
Not
<=3 ach in Climate Zones 3-8.
j❑Not
Observable
_
;❑Not
Applicable
403.2.2
Duct tightness test result of <=4
cfm/100 cfm/100❑Complies
[F1411
cfm/100 ft2 across the system or
ft2 ft2 j❑Does
Not
tl,
<=3 cfm/100 ft2 without air
j❑Not
Observable
handler @ 25 Pa. For rough -in
�',❑Not
Applicable j
tests, verification may need to
occur during Framing Inspection.
403.2.2.1
Air handler leakage designated
❑Complles
[FI2411
by manufacturer at <=2%of❑Does
Not
design air flow.
❑Not Observable
❑Not Applicable j
403.1.1
Programmable thermostats
❑Complies
[FI9]2
installed on forced air furnaces.
❑Does Not
V
❑Not Observable
❑Not Applicable
403.1.2
Heat pump thermostat installed
❑Complies
[F]10]2
on heat pumps.
❑Does Not
lQJ
❑Not Observable
`
❑Not Applicable
403.4.1
Circulating service hot water
❑Complies
[Fill]2
systems have automatic or
❑Does Not
v '.accessible
manual controls.
❑Not Observable
❑Not Applicable j
403.5.1
All mechanical ventilation system❑Complies
[F12512
fans not part of tested and listed
❑Does Not
HVAC equipment meet efficacy
❑Not Observable
and air flow limits.
❑Not Applicable j
404.1 175%
of lamps in permanent
❑Complies
[F1611
fixtures or 75% of permanent
❑Does Not
!fixtures
have high efficacy lamps.
!,Does
not apply to low -voltage
❑Not Observable ,
(lighting.
❑Not Applicable
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 LOW Impact (Tier 3)
Project Title: Adalynn Plan Report date: 11/07/17
Data filename: Page 8 of 9
""��'
#
Final Inspection Provisions
Plans Verified
Field Verified
Complies?
Comments/Assumptions
& Re .ID
Value
Value
404.1.1
Fuel gas lighting systems have<
-❑Complies
[FI23]3
no continuous pilot light.
�'`�
❑Does Not
i#"�&'
❑Not Observable
01.3 Compliance certificate posted.
F17 )2
J
!03.3 Manufacturer manuals for
FI18]3 mechanical and water heating
Q systems have been provided.
Additional Comments/Assumptions:
Does Not
Not Observable
Not Applicable
Complies
Does Not
Not Observable
1 JHlgh Impact (Tier 1) 2Medium impact (Tier 2) 3 Low Impact( 3)
Project Title: Adalynn Plan Report date: 11/07/17
Data filename: Page 9 of 9
fz2012 IECC Energy
Efficiency Certificate
Insulation Rating R -Value
Above -Grade Wall 22.00
Below -Grade Wall 19.00
Floor 22.00
Ceiling / Roof 50.00
Ductwork (unconditioned spaces):
Window 0.27
Door 0.27
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments