HomeMy WebLinkAboutLOAD SHORT FORM - 17-00645 - 762 S 2275 W - New SFR+ wrightsoft Load Short Form High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745.8056 Fax: 208-745.0817 Email: highcountryhtg@gmail.com Project Information Job: SF8B8 Date: 10/16/17 By: Vince Byram For: Cody Puzey Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (Cfm) 3758 Yellowstones Hwy, Idaho Falls, Id 83401 3121 355 Phone: 208-529-2116 Room2 156 4318 328 121 Design Information 150 2242 Htg Clg Infiltration Room4 Outside db (°F) -6 89 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TO (°F) 76 14 Fireplaces 1121 Daily range - H 45 569 Inside humidity (%) 50 50 Room8 154 Moisture difference (gr/Ib) 62 -31 61 101 HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade GOODMAN, JANITROL, AMANA DISTI... Model GMH950703BX Cond GSX130241C` AHRI ref 2002183 Coil Capf303Obx AHRI ref 4765510 Efficiency 95 AFUE Efficiency 11.0 EER, 13 SEER Heating input 69000 Btuh Sensible cooling 16100 Btuh Heating output 52440 Btuh Latent cooling 6900 Btuh Temperature rise 62 °F Total cooling 23000 Btuh Actual air flow 920 cfm Actual air flow 767 cfm Air flow factor 0.028 cfm/Btuh Air flow factor 0.073 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area (ft') Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (Cfm) Room1 604 12705 3121 355 228 Room2 156 4318 328 121 24 Room3 150 2242 274 63 20 Room4 250 3439 1696 96 124 Room5 242 2074 1110 58 81 Room6 156 2735 1121 76 82 Room7 45 569 81 16 6 Room8 154 2180 1386 61 101 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. sa 2017 -Oct -24 08:37:36 wrighltSO�' RlghtSullii) U niversal 2017 17.0.10 RSU20477 Page ...ts\wnghlsoftware\Km1chner\SFBB8 pnnoelon.rup Calc= We House fares: N Entire House d 1877 32960 10519 920 767 Other equip loads 1780 328 Equip. @ 0.94 RSM 10196 Latent cooling 0 TOTALS 1877 34740 10196 920 767 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2077 -Oct -240 Wright$Oft Rig htSuite® U niversal 2017 17.0.10 RSU20477 Pa9ge2 ...is\wrightsoftware\Kartchner\SF8S8 princelon.rup Calc =MJB House faces: N + wrightsoft° Building Analysis High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745.8056 Fax: 208-745-0817 Email: highcounlryhtg@gmail.com For: Location: Idaho Falls, ID, US Elevation: 4741 ft Latitude: 44°N Outdoor: Drybulb (°F) Dailyrange (°F) Wet bulb (° F) Wind speed (mph) Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Job: SF888 Date: 10116/17 By: Vince Byram Component Indoor: Heating % of load Indoor temperature ('F) 70 10941 Design TD (°F) 76 23.7 Relative humidity (%) 50 Heating Cooling Moisture difference (gr/Ib) 61.5 -6 89 Infiltration: 1.5 - 34 (H ) Method Simplified 60 Construction quality Average 15.0 7.5 Fireplaces 0 Component Btuh/ft' Btuh % of load Walls 4.9 10941 31.5 Glazing 23.7 4992 14.4 Doors 22.0 900 2.6 Ceilings 1.5 1731 5.0 Floors 4.0 4509 13.0 Infiltration 4.0 9888 28.5 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 1780 5.1 Adjustments 0 Total 34740 100.0 Cooling Component Btuh/ft2 Btuh % of load Walls 0.5 1051 9.7 Glazing 34.3 7218 66.5 Doors 5.4 219 2.0 Ceilings 0.8 957 8.8 Floors 0.1 127 1.2 Infiltration 0.4 947 8.7 Ducts 0 0 Ventilation 328 3.0 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 10847 100.0 Latent Cooling Load = 0 Btuh Overall U -value = 0.064 Stuh/ft'--°F Data entries checked. Cooling 75 14 50 -31.5 Wri htBOft' 2017 -Oct -2408:37:36 9 Rig htSuiaO U niversal 201717.0.10 RSU20477 Page 1 ...tskwdghtsofhvareM<a1chnerXSF8B8 pdnceton.rup Cale =MJ8 House faces: N Component Constructions Job: SF8B8 +wrightsoft p Date: 10116177 By: Vince Byram High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-7455056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Location: Or Indoor: Heating Cooling Idaho Falls, ID, US Loss Indoor temperature (TF) 70 75 Elevation: 4741 ft W Design TD (°F) 76 14 Latitude: 44oN BWhM Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Drybulb(T) -6 89 Infiltration: in 585 Dailyrange (°F) - 34 ( H ) Method Simplified 0,47 Wetbulb(°F) - 60 Construction quality Average 0.065 Wind speed (mph) 15.0 7.5 Fireplaces 0 257 Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain 50 0.320 W BtuhN-°F V-'F,Hluh Bluhr Btuh BWhM Btuh Walls 0 22.8 570 34.1 854 w 79 0.320 Firm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int in 585 0.065 22.0 4.94 2890 0,47 278 fnsh, 2"x6" wood frm, 16" o,c. stud: Frm wall, vnl ext, 3/8" wood shth, a 542 0.065 22.0 4.94 2676 0.47 257 r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud s 585 0.065 22.0 4.94 2890 0.47 278 0.84 w 503 0.065 22.0 4.94 2486 0.47 239 127 all 2215 0.065 22.0 4.94 10941 0.47 1051 Partitions (none) Windows 61 C: 61 C; 6.67 ft head ht Doors 11 P0: Door, mtl pur core type Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh Floors 19A-30bscp: Part Floor, carpet 8r fnsh, r-30 ins, frm gr, 12" thkns, 1/2" gypsum board int fnsh 22B-1 Ocpm: Bg floor, heavy dry or light damp soil, on grade depth, r-10 edge ins, carpet fir fnsh e 56 0.300 0 22.8 1284 34.1 1923 e 50 0.320 0 24.3 1216 34.4 1721 w 25 0.300 0 22.8 570 34.1 854 w 79 0.320 0 24.3 1921 34.4 2720 all 210 0.320 0 23.7 4992 34.3 7218 w 41 0.290 10.5 22.0 900 5.37 219 1139 0.020 50.0 1.52 1731 0.84 957 319 0.034 30.0 2.17 692 0.40 127 138 0.355 10.0 27.0 3723 0 0 3 0.355 10.0 27.0 94 0 0 all 141 0.355 10.0 27.0 3817 0 0 2017 -Oct -24 08:37:36 +C wrightSOft' RightSulteO U niversal 2017 17.0.10 RSU20477 Page 1 ...is\wrightsoftware\KaruhnenSF8B8 pdnceton.rup Cale =MJ8 House faces; N + wrightsoft Project Summary High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-7455056 Fax: 208-745-0817 Email: highcountryhtga@gmail.com Promect Information For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Notes: Job: SF8B8 Date: 10/16/17 By: Vince Byram Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Design Make Goodman Mfg. Trade GOODMAN Weather: Idaho Falls, ID, US Trade GOODMAN, JANITROL, AMANA DISTI... Winter Design Conditions Summer Design Conditions Outside db -6 OF Outside db 89 OF Inside db 70 OF Inside db 75 OF Design TO 76 OF Design TD 14 OF Efficiency 11.0 EER, 13 SEER Daily range H Btuh Sensible cooling 16100 Btuh Relative humidity 50 % Latent cooling 6900 Btuh Moisture difference -31 gr/Ib Heating Summary 23000 Btuh Sensible Cooling Equipment Load Sizing Structure 32960 Btuh Structure 10519 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (25 cfm) 1780 Btuh Central vent (25 cfm) 328 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 34740 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Infiltration Equipment sensible load 10196 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure -1316 Btuh Ducts 0 Btuh Heating Cooling Central vent (25 cfm) -456 Btuh Area (ft') 1877 1877 Equipment latent load 0 Btuh Volume (ft3) 16893 16893 Air changes/hour 0.50 0.26 Equipment total load 10196 Btuh Equiv. AVF (cfm) 141 73 Req. total capacity at 0.70 SHR 1.2 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade GOODMAN, JANITROL, AMANA DISTI... Model GMH950703BX Cond GSX130241C* AHRI ref 2002183 Coil Capf303Obx AHRI ref 4765510 Efficiency 95 AFUE Efficiency 11.0 EER, 13 SEER Heating input 69000 Btuh Sensible cooling 16100 Btuh Heating output 52440 Btuh Latent cooling 6900 Btuh Temperature rise 62 OF Total cooling 23000 Btuh Actual air flow 920 cfm Actual air flow 767 cfm Air flow factor 0.028 cfm/Btuh Air flow factor 0.073 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W1'i htSoft' 2017 -Oct -2408:37:36 Rig htSuiteO Universal 2017 17.0.10 RSU20477 Page l ...ts\wrightsoftwareXKarlchner\SF8B8 princeton.rup Cale =MJ8 House faces: N + wrightsoft AED Assessment High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-7458056 Fax: 208-745-0817 Email. highcountryhtg@gmail.wni For: Location: Idaho Falls, ID, US Elevation: 4741 ft Latitude: 44"N Outdoor: Drybulb (°F) Dailyrange (°F) Wet bulb ('F) Wind speed (mph) Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Heating Cooling -6 89 - 34 ( H ) - 60 15.0 7.5 LIMUT O-4%JIT re i Job: SF8B8 Date: 10/16/17 By: Vince Byram Indoor: Heating Indoor temperature (°F) 70 Design TD (°F) 76 Relative humidity (%) 50 Moisture difference (gr/Ib) 61.5 Infiltration: w aow AEbrtmx Maximum hourly glazing load exceeds average by 28.3%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh Cooling 75 14 50 -31.5 2017 -Oct -24 08:37:36 .� Wrightsoft, Right-Sa Rat U niversal 2017 17.0.10 RSU20477 Pagel km...Is\wrightsoftware\Kartchner\SFBBB pdnceton.rup Calc = MJ8 House faces'. N +{� wrightsoft Right -J® Worksheet Job: SF8B8 Date: 10/16/17 By: Vince Byrom High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Entire House Roomi 2 Exposed wall 274.0 it 101.0 if 3 Room height 9.0 ft d 90 1t heaUcool 4 Room dimensions 1.0 x 604.0 ft 5 Room area 1877.0 fl' 604.0 fP TY Construction U -value Or I HTM Area R' Load Area ft' Load number (Btuh/fP-°F1 (Btuh/f N) or perimeter (ft) (Btuh) or perimeter ((t) (Btuh) Heat I Cool Gross I N/P/S HeatCool Gross N/P/S Heat Cool 6 W Frm wall, vul ext, 3 0.065 n 4.94 0.47 585 585 2890 278 297 297 1467 141 W Fun wall, vnl ext, 3 0.065 a 4.94 0.47 648 542 2676 257 216 160 789 76 i --G 61C 0.300 a 22.80 34.14 56 0 1284 1923 56 0 1284 1923 61C 0.320 a 24.32 34.42 50 0 1216 1721 0 0 0 0 11 W Frm wall, ant ext, 3 0.065 s 4.94 0.47 585 585 2890 278 180 180 889 85 Fan wall, vul ext, 3 0.065 w 4.94 0.47 648 503 2486 239 216 170 840 81 61C 0.300 w 22.80 34.14 25 0 570 854 25 0 570 854 61C 0.320 w 24.32 34.42 79 0 1921 2720 0 0 0 0 11P0 0.290 w 22.04 5.36 41 41 900 219 21 21 463 113 C 16B-50ad 0.020 - 1.52 0.84 1139 1139 1731 957 22 22 33 18 F 19A-30bsco 0.034 - 2.17 0.40 319 319 692 127 0 0 0 0 F 22B-10cpm 0.355 - 26.98 0.00 760 138 3723 0 604 101 2725 0 F 22B-10cpm 0.355 - 26.98 0.00 60 3 94 0 0 0 0 0 6 c)AEG excursion0 -519 Envelope loss/gain 23073 9572 9061 2772 12 a) Infiltration 9888 947 3645 349 L) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 t 13) 32960 10519 12705 3121 Less externalloatl 0 0 0 Less transfer 0 0 0 Redistribution =329600 0 0 0 14 Subtotal 10519 12705 3121 15 Duct loads 0 -0% 0% 0 0 1 329201 10701121 I 1 723551 32281 1 Aotaegu�etl (cfm) I 1 7671 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrighk9PT'Y2017-Oct-2408:37:36 Right -Suited Universal 2017 17.0.10 RSU20477 Page 1 ...is\wrighlsoftware\Kadchner\SF8B8 princetonsup Calc = i House faces: N +4+wrightsoft Right -J@ Worksheet Job: SF8138 Date: 10/16/17 By: Vince Byram High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email highcountryhtg@gmail.com 1 Room name Room2 Room3 2 Exposed wall 37.0 ft 25.0 fl 3 Room height 9.0 R heat/cool 9.0 If heat/caol 4 Raom tlimensions 12.0 x 13.0 fl 10.0 x 15.0 ft 5 Room area 156.0 n' 150.0 ft' T Ty Construction U -value I Or I HT1/1 I Area ft' l) I Load Area fl' ( 1 Load number (Bt uh/f 2 Y (Btuhlf P) or perimeter (ft) (etuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross NIPIS Heat Cool 6 W Fire wall, vnl ext, 3 0.065 n 4.94 0.47 0 0 0 0 135 135 667 64 vnl ext, 3 0.065 a 4.94 0.47 108 108 534 51 90 90 445 43 T�I'mwall, 61C 0.300 a 22.80 3414 0 0 0 0 0 0 0 0 61C 0.320 e 24.32 34.42 0 0 0 0 0 0 0 0 11 W Fen wall, vul ext, 3 0.065 s 4.94 0.47 117 117 578 56 0 0 0 0 Fm wall, vnl ext, 3 0.065 w 4.94 0.47 108 88 436 42 0 0 0 0 61C 0.300 w 22.80 34.14 0 0 0 0 0 0 0 0 61c 0.320 w 24.32 34.42 0 0 0 0 0 0 0 0 11P0 0.290 w 22.04 5.36 20 20 437 106 0 0 0 0 C 16B-50ad 0.020 1.52 0.84 0 0 0 0 150 150 228 126 F 19A-30bsco 0.034 - 2.17 0.40 0 0 0 0 0 0 0 0 F 228-10cpm 0.355 - 26.98 0.00 156 37 998 0 0 0 0 0 F 2213-101 0.355 - 26.98 0.00 0 0 0 0 0 0 0 0 6 cj AED excursion -55 -05 Envelope Il 2982 200 1 1 1339 187 12 a) Infiltration 1335 128902 86 b) Roam ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 4318 328 2242 274 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 :2242D15 14 Subtotal 4318 328 Duct loads .0% 0% 0 0 -0% 0% 412811 328 1 1 22631 2201 1 Av reQuvedl(cfr) 1 1 1 241 Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed. 2017 -Oct -24 08:37: Rig hlSuite®Universa1207717.0.10 RSU20477 page36 W �ightsoft` ...tewrightsoftwareWartchner\SF8B8 prineetoo.rup Cale =MJB House faces: N -►}>f-wrightsoft Right -J® Worksheet High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax 208-745-0817 Email highmunlryhtg@gmaiLcom Job: SF8B8 Date: 10/16/17 By: Vince Byrarll 1 Room name Room4 Rooms 2 Exposed wall 31.0 ft 14.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat1cool 4 Room dimensions 1.0 x 250.0 ft 1.0 x 242.0 it 5 Room area 250.0 ft° 242.0 fP Ty Construction U-valueII Or I HTM I Area ((F) I Load I Area (W) Load number I(at uhlfP-° (et uh/fv) or perimeter (ft) (Btuh) or perimeter (ft) (Brun) Heat Cool GrossN/P/S Heat I Cool Gross NIP/S Heat I Cool 6 W Find wall, vnl ext, 3 0.065 n 4.94 0.47 144 144 711 68 0 0 0 0 Frm wall, vnl ext, 3 0.065 a 4.94 0.47 0 0 0 0 126 101 499 48 I -G 61 C 0.300 e 22.80 34.14 0 0 0 0 0 0 0 0 r --G 61C 0.320 a 24.32 34.42 0 0 0 0 25 0 608 861 11 W Fruit wall, vol ext, 3 0.065 is 4.94 0.47 0 0 0 0 0 0 0 0 Frm wall, vnl ext, 3 0.065 w 4.94 0.47 135 106 524 50 0 0 0 0 61C 0.300 w 22.80 34.14 0 0 0 0 0 0 0 0 61C 0.320 w 24.32 3442 29 0 705 998 0 0 0 0 11P0 0.290 w 22.04 5.36 0 0 0 0 0 0 0 0 C 1613-50ad 0.020 - 1.52 0.84 250 250 380 210 242 242 368 203 F 19A36bsCo 0.034 - 2.17 0.40 0 0 0 0 0 0 0 0 F 2213-10cpm 0.355 - 26.98 0.00 0 0 0 0 0 0 0 0 F 228-10cpm 0.355 - 26.98 0.00 0 0 0 0 60 3 94 0 6 c)AED excursion 262 -50 Envelope loss/gain 2320 1589 1568 1061 12 a) Infiltration 111E 107 505 48 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 3439 1696 2074 1110 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3439 1696 2074 1110 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 o9 3491 6 16941 I I 2058 101A 1 8ta1. fm I I I 12 Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed. A wrightsoft` 2017 -Oct -2408:3T.36 R ig hi ii Univ ers at 201717.0.10 RSU 20477 Page 3 ._is\wrightsoftware\Kanchnef\$F8B8 princetonsup Calc = MJ8 House faces: N + wrightsoft• Right -J® Worksheet High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-74543056 Fax: 208-745-0817 Email: highcounlryhtg@gmail.com Job: SF8B8 Date: 10116117 By: Vince Byrom 1 Room name Rocm6 Room? 2 Exposed wall 25.0 it 5.0 ft 3 Room height 9.0 ft heat/ccol 9.0 It heat/cool 4 5 Room dimensions Room area 12.0 x 13.0 ft 156.0 fl' 9.0 x 5.0 it 45.0 fN Ty Construction U -value Or HTM Area (ft') I Load Area (ft') I Load number (Bt uh/fl'-°F (Bt uhlf P) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heal Cool Gross N/PIS Heat Cool 6 W Firm wall, vni ext, 3 0.065 in 4.94 0.47 0 0 0 0 0 0 0 0 Firm wall, vni ext, 3 0.065 a 4.94 0.47 108 83 410 39 0 0 0 0 61C 0.300 a 22.80 34.14 0 0 0 0 0 0 0 0 61C 0.320 a 24.32 34.42 25 0 608 861 0 0 0 0 11 W Firm wall, vni ext, 3 0.065 s 4.94 0.47 117 117 578 56 45 45 222 21 Firm wall, vni ext, 3 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 61C 0.300 w 22.80 34.14 0 0 0 0 0 0 0 0 61C 0.320 w 24.32 34.42 0 0 0 0 0 0 0 0 11P0 0.290 w 22.04 5.36 0 0 0 0 0 0 0 0 C 16BSOad 0.020 1.52 0.84 156 156 237 131 45 45 68 38 F 19A30bsco 0.034 2.17 0.40 0 0 0 0 45 45 98 18 F 22B-10cpm 0.355 - 26.98 0.00 0 0 0 0 0 0 0 0 F 22B-10cpm 0.355 26.98 0.00 0 0 0 0 0 0 0 0 6j c)AED excursion -52 1 1 -13 Envelope lasslgain 1 1833 1034 388 64 12 a) Infiltration 902 86 17 b) Room ventilation 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 EIE0 0 Appliances/other 0 Subtotal (lines 6 to 13) 2735 1121 569 81 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2735 1121 569 81 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 2735 1121 569 81 Air required (dm) 76 82 16 6 .1, Calculations approved by ACCA to meet all reouirements of Manual J 8th Ed. g wrightsof , 2017-0G-2408:37:36 AGCY'. RightSuite® Universal 2017 17.0.10 RSU20477 Page ...is\wrightsoftwafe\KanchneASF8B8 pnncelon.rup Cale =MJ8 House faces: N + wrightsoft- Right -JO Worksheet High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryIng(iiigmail.com Job: SF8B8 Date: 10/16/17 By: Vince Byram 1 Room name Room8 Room9 2 Exposed wall 14.0 it 22.0 It 3 Room height 9.0 X he alcool 9.0 If heat/cool 4 Room dimensions 11.0 x 14.0 If 10.0 x 12.0 1t 5 Room area 154.0 ft' 120.0 ft' Ty Construction U -value Or HTM Area (ft') Load Area (f P) Load number an uhlft'°F (Bt uh/f P) or perimeter (ft) (Star) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Fnn wall, vnl ext, 3 0,065n 4.94 0.47 9 9 44 4 0 0 0 0 Frm wall, vat ext, 3 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 61C 0.300 a 22.80 34.14 0 0 0 0 0 0 0 0 61C 0.320 a 24.32 34.42 0 0 0 0 0 0 0 0 11 W Fran wall, vnl ext, 3 0.065 s 4.94 0.47 18 18 89 9 108 108 534 51 Frm wall, vat ext, 3 0.065 w 4.94 0.47 99 74 366 35 90 65 321 31 61C 0.300 w 22.80 34.14 0 0 0 0 0 0 0 0 61C 0.320 w 24.32 34.42 25 0 608 861 25 0 608 861 11P0 0.290 w 22.04 5.36 0 0 0 0 0 0 0 0 G 16B50ad 0.020 1.52 0.84 154 154 234 129 120 120 182 101 F 19A30bsco 0.034 - 2.17 0.40 154 154 334 62 120 120 260 48 F 22B-10cpm 0.355 26.98 0.00 0 0 0 0 0 0 0 0 F 22B-10cpm 0.355 26.98 0.00 0 0 0 0 0 0 0 0 61 c) AED excursion 1 2381 1 235 Envelope loss/gain 1675 1338 1905 1327 12 a) Infiltration 505 48 794 76 b) Roomvemilation 0 0 0 0 13 Internal gains: Occupants 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines filo 13) 2180 1386 2699 1403 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2180 1386 2699 1403 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 T I room load 27611 38 11081 2fi75I 11021 Aotae9uir d (ctm) I I I I I Calculations annroved by ACCA to meet all requirements of Manual J Sth Ed. w rightSOft-2017-Oct-24 08:37:36 Rig htSuile® U niversal 2017 17.0.10 RSU20477 Page 5 ._ts\wrightsohwar a<mtchnenSF868 princeton.rup Calc =MJ8 House faces: N 2nd Story 63 cfm 82 cfm �81 cfm Room6 Room3 Room5 82 cfm 159 cfm 87 cfm Room? K 16 cfm 102 cfm Room4 101 cf%om9 Room8 K62 cfm ®`62 cfm 91102 cfm K101 cfm Job #: SF8B8 Performed by Vince Byram for: Cody Puzey 3758 yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highwuntryhtg@gmaii.com Scale: 1 :68 Page 1 Righ tSuite ® Universal 2017 17.0.10 RSU20477 2017 -Oct -24 08:37:52 ...re\Kartchner\SF8B8 princeton.rup 0 Main Floor Job #: SF8138 Performed by Vince Byram for: Cody Puzey 3758 Vellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryhtg@gmail.com r cfm �3 Scale: 1 : 68 Page 2 RightSuite® Universal 2017 17.0.10 RSU20477 2017 -Oct -24 08:37:52 ...re\Kartchner\SF8B8 princelon.rup +I+ wrightsoft, Duct System Summary High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208.745-8056 Fax: 208.745.0817 Email: highcountryhtg®gmall.mm Project• For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.70 in H2O 0 in H2O 0.70 in H2O 0.424 / 0.276 in H2O 0.096 in/100ft 920 cfm 730 Job: SF8B8 Date: 10/16/17 By: Vince Byram Cooling 0.70 in H2O 0 in H2O 0.70 in H2O 0.424 10.276 in H2O 0.096 in/100ft 767 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Rooms h 3176 89 57 0.105 6.0 0x0 ShMt 37.0 365.0 st4A Room h 3176 89 57 0.107 6.0 0x0 ShMt 22.0 375.0 st4 Rooms -B h 3176 89 57 0.096 6.0 0x0 ShMt 55.0 385.0 st413 Roomt-C h 3176 89 57 0.110 6.0 0x0 ShMt 42.0 345.0 st4 Room2 h 720 20 4 0.180 6.0 0x0 ShMt 10.0 225.0 sty Room2-A h 720 20 4 0.130 6.0 0x0 ShMt 15.0 310.0 st4 Room2-B h 720 20 4 0.131 6.0 0x0 ShMt 13.0 310.0 st4 Room2-C h 55 20 4 0 0 0x0 ShMt 0 0 Room2-D h 55 20 4 0 0 0x0 ShMt 0 0 Room2.E h 55 20 4 0 0 0x0 ShMt 0 0 Room3 h 2242 63 20 0.103 6.0 0x0 ShMt 36.0 375.0 st4A Rocm4 C 848 48 62 0.096 6.0 0x0 ShMt 47.0 395.0 st4A Rocm4-A C 848 48 62 0.097 6.0 0x0 ShMt 52.0 385.0 st4A Roams C 1110 58 81 0.112 6.0 0x0 ShMt 23.0 355.0 st4 Rooms C 1121 76 82 0.169 6.0 0x0 ShMt 11.0 240.0 st4 Room7 h 569 16 6 0.244 6.0 0x0 ShMt 14.0 160.0 st1 Rcxn8 c 1386 61 101 0.105 6.0 0X0 ShMt 39.0 365.0 st4 Rooms c 1403 75 102 0.151 6.0 0X0 ShMt 30.0 250.0 st4 2017 -Oct -24 08:37:37 - wf7ghltSOft' Right -Suite® Universal 201717.0.10RSU20477 Paget icCfl... ts\wrightsoftware\KanchnedSF8B8princeton.rup Cale =MJ8 House faces: N Return Branch Detail Table Name Trunk Htg Clg Design Veloc Diam H x W Duct Stud/Joist Opening (in) Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4A Peak AVF 336 257 0.096 504 9.2 8 x 12 ShtMetl st4 st4 Peak AVF 824 745 0.096 741 12.9 8 x 20 ShtMetl st1 st5 Peak AVF 20 4 0.180 30 2.8 8 x 12 ShtMetl st1 st4B Peak AVF 89 57 0.096 133 5.6 8 x 12 ShtMetl st4A st1 Peak AVF 860 755 0.096 774 13.1 8 x 20 ShtMetl 10x9 Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matt Trunk rb4 0x0 61 101 126.0 0.219 320 5.0 3.25x14 10x9 SJSp rt1 rb2 0x0 76 82 126.0 0.219 259 4.6 3.25x14 10x9 SJSp a1 rb6 0x0 74 87 149.0 0.185 275 4.9 3.25x14 10x9 SJSp rt1 rb1 0x0 475 252 206.0 0.134 501 9.8 3-3.25x14 3-10x27 SJSp rt1 rb5 0x0 159 144 288.0 0.096 502 7.0 3.25x14 10x9 SJSp rt1A rb3 0x0 75 102 0 0 324 0 3.25x14 10x9 SJSp Return Trunk Detail Table 2017-0d-24 08:37:37 wri htsoft' RighlSuite® U niversal 201717.0.10 RSU20477 Page ...WwrightsoftwarelxanchneAMBB pnnceton.rup Cale =MJB House faces: N Trunk Htg Gig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rtt Peak AVF 845 665 0.096 633 13.0 8 x 24 ShtMetl rt1A Peak AVF 159 144 0.096 238 7.0 8 x 12 ShtMetl rt1 2017-0d-24 08:37:37 wri htsoft' RighlSuite® U niversal 201717.0.10 RSU20477 Page ...WwrightsoftwarelxanchneAMBB pnnceton.rup Cale =MJB House faces: N