Loading...
HomeMy WebLinkAboutAPPLICATIONS & COMCHECK - 17-00613 - 900 Jet Stream Dr - Headwaters Construction - HeadquartersC I TY OF REXBURG 041, Anmricn's Family Cmnmunity PERMIT POLICIES ACKNOWLEDGMENT Building Safety Department City of Rexburg 35 North 151, East Rexburg, Idaho 83440 The City of Rexburg Building Safety Department is determined to provide excellent customer service. In an effort to help you understand the City of Rexburg Permit Policies, listed below are several policies which you are required to know prior to proceeding with your project. Any construction within the City of Rexburg which requires a permit shall not begin until an approved permit is obtained. If you do not have a Pink Building Permit signed by the Building Inspector, then you do not have an approved permit. qrassng without the pink building permit signed by the Building Inspector will result in double fees to be and the project to be red tagged. If your project is red tagged, halting all construction, only a City essed l may remove the red tag. If the red tag is removed by anyone but a City Official, citations may be I No building may be occupied without receiving a signed Certificate of Occupancy. o If a building is occupied without receiving a signed Certificate of Occupancy, citations may be issued and the occupants may be evicted. Scheduling inspections is the responsibility of the applicant and their contractor. Inspections need to be called into the hotline and not to the inspector. Inspections called in later than 8 AM will be scheduled for the following business day. If an inspection is not done, the inspector may require any measures to be taken to allow him to correctly perform the inspection. (Example: If the electrical rough in inspection is not done and the sheetrock has been I - s put up, the inspector may require the sheetrock to be removed in order to perform the electrical rough in inspection.) Construction on any project can begin ONLY when you have received a Pink Building Permit from the Building Department. Occupancy of any structure can begin ONLY when you have received an official Certificate of Occupancy from the Building Department. These documents must be signed by the appropriate authorities from the City of Rexburg. Any approvals can be verified by calling (208) 372-2341. Or Even if you hear from an inspector that you're good to go, ultimately if you do not have a Building Permit or Certificate of Occupancy, the above policies will be enforced. 5 It is your responsibility to inform anyone on your project of the above policies. All sub -contractors will be held to this standard with no exceptions. orThe above policies will be enforced to all, regardless Applicant's Name (print): WAI-34 Inspections must be called in before 8 AM on the day the Inspection I, Inspection Hotline -(208)372.2344 www.rexburg.mit is passejon to them or not. Date:�l l m requests called in after 8 AM will be scheduled for the next business day. Permit Technician -(208)372.2341 Revised 10/2016 CITY OF REXBURG Americai Family Community PROPERTY LINES Building Safety Department City of Rexburg 35 North 1st East Rexburg, Idaho 83440 Each site plan that is submitted to the City of Rexburg for the Building Permit process requires that property lines are shown accurately. It is the Developer's responsibility to correctly identify on the site plan the location of these lines in reference to the public right-of-way, other adjoining property lines, the street, other structures and all utility lines. The Developer should find property pins that are still available at the lot in question. If these pins do not exist or have become unrecognizable then a new survey should be performed. Accurate property line information is a must for a timely review. In addition to finding existing property pins, legal descriptions should be checked. The best way to identify property line location is with a land survey. The City of Rexburg has aerial photos and a parcel line layer that can be checked, but they are only a tool and are not guaranteed for accuracy. If you want to request a copy of your lot, see the front counter at the Community Development Department. I have read and understand the above requirements. Date Ji"lly WA4Q>✓I Printed Name Inspection Hotline -(208)372.2344 w .rexburg.org Permit Technician -(208)372.2341 Revised 10/2016 t pF]tbl!q� h� e' CITY OF REXBURG BUILDING PERMIT FORM 200 C%al, updnrd 10/2016 Amedc4 Family CAmmubity BUILDING APPLICATION Commercial Addition Building Safety Department City of Rexburg 3S North 1st East Rexburg, Idaho 83440 For Office Use Permit Number. -ooG 13 Zoning:. L .'3h F Znflt dH a l Application Fee: ❑ $1000/Building 1. Property Owner Name: AabW4T A5 G07tyrAftcTW CD0,g04,,.ef Address:(p�q 9�Oe 5 �alImI City• Vel; roAL State: 10 Zip Code: 834q_47 Phone: Zn3?,17 t2 Email: 2. Apame: Iwplicant A �� N�J 2 t4l A-r9Gw.l Role:(Owner, Tenant, Contractor, etc.) _AI& 1 r/- Address: l l or l h (3cVE . City: •t.et G State: 10 Zip Code: R'1 4.40 Phone: r 9D ZG G 7 Email: t,,� f, / ta,g east% Contact/Rep. Name: 3. General Contractor Under Idaho Building Code, a registered contractor must do the work for a Commercial Building. Name: Headwaters Construction Registration #: RCE -2339 Exp.: 17/14/17 Address: 639 w 9500 s, suite 1 City: victor State: to Zip Code: 9345s Phone: 2Da-787-8o4o Email: infoMeadwaterscc Contact/Rep. Name: arver Hastings Phone: 2oa-313-46s4 Email: bhastinga headwaterscc General Contractor Authorized Signature: fi ia� Date: ie/a /f;• A copy ofyour state registration/license is required to be on file. Is is the first timeyou have done work in the City of Rexburg, please provide a photocopy ofyour license. Ifyou are unsure ifyour license is on ff1e, please check with the Permit Technician by calling (208) 372.2341. 4. Project Description Address: At KW WAC LoT- lb i3t d ck � Project Description: �- 1G� B` • Square footage of addition: 7. �a 5Q• �7 Q F� • Total cost of project - materials and labor: $ 00 000 • Check all that apply: ❑ Mechanical: Cost $ ❑ Electrical: Cost $ ❑ Plumbing: Cost $ ❑ Fire Alarm: Cost $ ❑ Fire Sprinkler: Cost $ Note: Any contractors involved will need to fill out their respective application. • Change of Occupancy? ❑ No ❑ Yes: New occupancy: • Other Comments (if any): Building Permit fees for commercial construction are charged based on square footoge and the City's estimated valuation. The application fee applies toward the fee total. For details on how fees are calculated, contact the Building Department There will also be a plan revlewfee totaling 10% of the building permit fee. APPLICANT'S SIGNATURE, CERTIFICATION AND AUTHORIZATION: Under penalty of perjury, l hereby certify that l have read this application and state that the Information herein Is correct and 1 swear that any information which may hereafter be given by me In hearings before the Planning and Zoning Commission or the City Council for the City of Rexburg shall be truthful and correct I agree to comply with all City regulations and State laws relating to the subject matter of this application and hereby authorized representatives of the City to enter upon the above-mentioned a fo pectionsp uses. NOTE: The building official may revoke a permit on approval issued under the provisions of the 2012 International Code In uses of any estatem mist esen on of fact in the application or on the plans on which the permit or approval was based. Permit void If not started within 180 days. Perml old ifwork for da s. JcFI�K,u7 a�rs� rol�(!7 Applicant's Name (prin . Signature: Date: Inspections must be calledih before B AM on the day the Inspection is requested. Inspection requests called In after B AM will be scheduled for the nextbusiness day C IT Y OF REXBURG — tv. Anmric4 Family Community Affidavit of Legal Interest Building Safety Department State of Idaho County of Madison' 1, �i2`fi2,—tlhlLS i0?i Name Address YI cv-4 City Being first duly sworn upon oath, depose and say: (If Applicant is also Owner of Record, skip to B) City of Rexburg 35 North 1st East Rexburg, Idaho 83440 I (?A*0 _ State A. That I am the record owner of the property described on the attached, and i grant my permission to: cJoAHN-i 06-Cs?,J II y2 &a4> mvie. Name Address to submit the accompanying application pertaining to that property. B. 1 agree to indemnify, defend and hold Rexburg City and its employees harmless from any claim or liability resulting from any dispute as to the statements contained herein or as to the ownership of the property which is the subject of the application. Dated this i 4 day of 467MICh 201 *7 Signature Subscribed and sworn to before me the day and year first above written. TORI WINN-FOLEY NOTARY PUBLIC STATE OF IDAHO Inspection Hotline - (208) 372.2344 Notary Public of Idaho Residing at: I/(, Lt V- My commission expires: 3110 1117_0 www.rexbrg.org Permit Technician -(208)372.2341 Revised 10, 2016 COMcheck Software Version 4.0.7.0 Envelope Compliance Certificate Project Information Energy Code: Project Title: Location: Climate Zone: Project Type: Vertical Glazing / Wall Area: Construction Site: jet Stream Dr. Rexburg, ID 83440 Building Area 2012 IECC Headwaters Headquarters Rexburg, Idaho 6b New Construction 18% Owner/Agent: Stan Marshall Headwaters Construction Jet Stream Dr Rexburg, ID 83440 Floor Area t -Office (Office) : Nonresidential 7532 Designer/Contractor: Johnny Watson JRWA 1152 Bond Ave Rexburg, ID 83440 (208) 359-2309 Additional Efficiency Package High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U. or R -Value R -Value U -Factor Factory.) Perimeter Roof 1: Attie Roof with Wood Joists, [Bldg. Use 1 - Office] 5519 50.0 0.0 0.021 0.021 Exterior Wall 1: Wood -Framed, 16" o.c., [Bldg. Use 1 - Office) 5212 21.0 10.0 0.036 0.051 Exterior Wall 2: Wood -Framed, 16" o.c., [Bldg. Use 1 - Office) 1766 21.0 0.0 0.062 0.051 Window 1: Metal Frame with Thermal Break:Fixed, Pert. Specs.: 548 --- --- 0.330 0.360 Product ID ACR -K-3-00002-00001, SHGC 0.35, (Bldg. Use 1 - Office) (b) Window 2: Vinyl/Fiberglass Frame:Fixed, Pert. Type: Energy code 669 --- --- 0.550 0.360 default, Double Pane with Low -E, Clear, SHGC 0.70, [Bldg. Use 1 - Office] Door is Insulated Metal, Swinging, [Bldg. Use 1 - Office] 42 --- --- 0.073 0.370 Door 2: Glass (> 50%glazing):Metal Frame, Entrance Door, Pert. Type: 21 --- --- 0.800 0.770 Energy code default, Double Pane with Low -E, Clear, SHGC 0.70, [Bldg. Use 1 - Office] Floor 1: Slab-On-Grade:Unheated, Horizontal without vertical 4 ff., 323 --- 10.0 0.640 0.540 [Bldg. Use 1 - Office] (c) (a) Budget U -tactors are used for software baseline calculations ONLY, and are not code requirements. (b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c) Slab -On -Grade proposed and budget U -factors shown in table are F -factors. Project Title: Headwaters Headquarters Report date: 10/04/17 Data filename: Untitled.cck Page 1 of 9 Envelope PASSES: Design I% better than code Envelope Compliance Statement Compliance Statement: The proposed envelope design represented !nWs document is sistent with the building plans, specifications, and other calculatlons submitted with this p' ion. The propo d envelope systems have been designed to meet the 2012 IECC requirements in CO eck Versi .0.7. d to c ply with any applicable mandatory requirements listed in the Inspection Checklist. J#&&Y t -*Old - Atcd- l Name - Title S14roture Date Project Title: Headwaters Headquarters Data filename: Untitled.cck Report date: 10/04/17 Page 2 of 9 COMcheck Software Version 4.0.6.0 Mechanical Compliance Certificate Project Information Energy Code: Project Title: Location: Climate Zone: Project Type: Construction Site: jet Stream Way Rexburg, ID Additional Efficiency Package Unspecified Mechanical Systems List Quantity System Type & Description 2012 IECC Headwaters Corp Office Rexburg, Idaho 6b New Construction Owner/Agent: Designer/Contractor: Dwayne Sudweeks Engineered Systems Assoc., Inc. 1355 E. Center St. Pocatello, ID 83201 208-233-0501 dcs@engsystems.com HVAC System 1 (Single Zone): Heating: 1 each - Duct Furnace, Gas, Capacity - 108 kStu/h Proposed Efficiency = 81.00% Ec, Required Efficiency = 80.00% Ec Cooling: 1 each - Single Package OX Unit, Capacity = 60 kBtu/h, Air -Cooled Condenser, Air Economizer Proposed Efficiency = 17.60 SEER, Required Efficiency: 13.00 SEER Fan System: FAN SYSTEM t — Compliance (Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Constant Volume, 1950 CFM, 2.0 motor nameplate hp Water Heater 1: Electric Storage Water Healer, Capacity: 50 gallons w/ CirculatIon Pump Proposed Efficiency: 0.86 EF, Required Efficiency: 0.86 EF Mechanical Compliance Statement Compliance Statement. The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.6.0 and to comply with any applicable mandatory requirements listed In the Inspection Checklist. I,wayM2 5w viee�* 1997. L*a Sq A40 lo15117 Name . Ttld 57Tnature Date Project Title: Headwaters Corp Office Data filename: C:\Users\Dwayne 15\Documents\COMcheck\Headwaters Office.cck Report date: 10/05/17 Page I of 9 COMcheck Software Version 4.0.6.1 Interior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: Construction Site: Rexburg, ID Additional Efficiency Package 2012 IECC Headwaters Office Building New Construction Owner/Agent: Headwaters Construction Rexburg, ID Designer/Contractor: Payne Engineering 1823 E. Center Street Pocatello, ID 83201 208-232.4439 High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Allowed Interior Lighting Power A Area Category B C D Floor Area Allowed Allowed Watts (ftz) Watts / fill (B X C) 1 -Office 7632 0.90 7049 Total Allowed Watts = 7049 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. 1 -Office LED 1: F3/F31: RECESSED CAN: Other: 1 46 16 736 LED 2: F4: 4FT STRIP: Other: 1 1 40 40 LED 3: F5: 4FT WALL: Other: 1 2 40 80 LED 4: F6: 6FT LINEAR PENDANT: Other: 1 2 60 120 LED 4 copy 1: F7/F7A: BFT LINEAR PENDANT: Other: 1 25 60 1500 LED 4 copy 2: F8/F8A: 12FT LINEAR PENDANT: Other: 1 4 100 400 LED 4 copy 3: F9PE/F9S: 8FT LINEAR PENDANT: Other: 1 2 100 200 LED 8: F10/F10E: 2X2 LAYIN: Other: 1 4 30 120 LED 8 copy 1: F11: 2X2 LAYIN: Other: 1 4 40 160 LED 10: F15: 1X4 SURFACE: Other: 1 5 32 160 Total Proposed Watts = 3516 Interior Liahtina PASSES: Design 5n% better than r-nde Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.6.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Project Title: Headwaters Office Building Report date: 09/14/17 Data filename: \\PESERVER\Payne Engineering Data\2017\Headwaters Office Building - Page 1 of 7 1793\05Calculations\Comcheck\Headwaters Office Bldg.cck Mike Payne, Designer Mike Payne 09/14/17 Name - Title Signature Date Project Title: Headwaters Office Building Report date: 09/14/17 Data filename: \\PESERVER\Payne Engineering Data\2017\Headwaters Office Building - Page 2 of 7 1793\05_Calculations\Comcheck\Headwaters Office Bldg.cck