HomeMy WebLinkAboutEMAIL BUILDING REVIEW - 17-00371-17-00373 - 720 Cornelison Ave - Juniper Sands Apartments - Bldg 1-3Johnny Watson From: Johnny Watson Sent: Wednesday, August 2, 2017 12:34 PM To: 'Quinton Owens'; Porter Wilkins (Porter.Wilkins@rexburg.org) Cc: Cody Summers (csummers@headwaterscc.com); John Eskelson <jeskelson@headwaterscc.com> Ceskelson@headwaterscc.com); Shalynn Lister (shalynn@leathamlegacy.com); Bron Leatham (bron@cpttruck.com); bob@idahopotato.cc Subject: Juniper Sands - Building Review Attachments: Draftstop.JPG; Elevation.JPG; Stair.JPG; SKMBT C28017080212180.pdf Quinton, We appreciate you taking the time to review the items identified on your review. Please see our responses and revisions to those items: 1- All doors in the 2hr rated wall shall be 90 min. See attached drawing 2- Draft stops shall occur per every two dwelling units. See attached drawing 3- Exit enclosure shall be rated as per 1022. Exterior wall extending 10' beyond exit enclosure shall have 1hr rating and openings in that area shall be % hr rated. See attached drawing 4- All entry doors in all units shall be 3'-0" doors. All usable doors inside Type A units shall have nominal 32" clear as per Technical Requirements of the Fair Housing. See attached detail 5- ComCheck has been provided. 6- Glazing at required locations shall be tempered. Please let us know if you have any other concerns. Thanks, Johnny Watson lwalson@jrwa.com 1152 Bond Avenue Suite A Rexburg, Idaho 83440 (208) 359-2309 Fax:(208)359-2271