Loading...
HomeMy WebLinkAboutFA SUBMITTAL - 17-00435 - 525 S Center St - BYUI - Kimball Ste 130 Remodel FIRE CONTROL INSTRUMENTS-GAMEWELL-BOSCH 1481 SOUTH MAJOR STREET S.L.C., UT 84115 P. 801-468-8300 F. 801-468-8305 Kimball Building – Level 1 Remodel BYU-Idaho Fire Alarm System Submittal September 1, 2017 KIMBALL BUILDING – LEVEL 1 REMODEL BYU-IDAHO FIRE ALARM SYSTEM SUBMITTAL Equipment Manufacturer: Gamewell-FCI Authorized Distributor: Nelson Fire Systems 1481 South Major Street Salt Lake City, UT 84115 801-468-8300 Data Sheet Part No. Description Gamewell-FCI E3 Series Emergency Evacuation System (Existing) Gamewell-FCI ASD-PL2F/B210LP Addressable Photo Smoke Detector w/Base Gamewell-FCI SPSWL Speaker/Strobe – Wall Mount Gamewell-FCI SPSCWL Speaker/Strobe – Ceiling Mount Gamewell-FCI HPFF8 NAC Power Supply (Existing) GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0637 Rev. O page 1 of 2 E3 Series® Control Panel SIGNALING Class 1 Class 2 High Rise S1869 Approved City of Denver City of Chicago ApprovedApproved 7165-1703:0125 3025415 APPROVED FM FDNY: COA-#6077 MEA Reference Certificate of Compliance VMA-45894-02C (Revision 1) Description The E3 Series® Expandable Emergency Evacuation Sys- tem by Gamewell-FCI is in the forefront of the latest gener- ation of fire alarm control panels. Employing the new high- speed Velociti® sensors, the E3 Series provides previously unattainable polling speed and response together with the flexibility demanded by today’s emergency evacuation sys- tems. In addition to their high-speed polling rate, the Veloc- iti Series of sensors feature bi-polar LEDs that flash green for normal polling, and light red steadily to indicate an alarm. The E3 Series is equipped with an 80-character LCD-E3 alphanumeric LCD display that allows 40 characters to be user-defined for custom installations. Up to six keyboard LCD displays may also be remotely located. In addition, you can install five of the familiar LCD-7100/RAN-7100 remote displays. The displays show instant system status information and can be connected in any desired area of an installation. A high-speed 32-bit processor easily tackles a wide array of applications from small office buildings to multi-complex, high-rise installations. The 64 node networking is made possible by 625K baud/ ARCNET communications using twisted-pair copper cable, fiber-optic cable, or a combination of both. In addition, the Addressable Node Expander (ANX) board expands the network to 122 nodes. The basic E3 Series is equipped with an ILI-MB-E3/ILI95- MB-E3 Intelligent Loop Interface-Main Board, ILI-S-E3/ ILI95-S-E3 Intelligent Loop Interface Expansion Board, ANX, and ASM-16 Addressable Switch Module that fea- tures 16 software programmable switches, each accompa- nied by red, green and yellow LEDs that can be programmed to indicate operation of the switches. Addi- tional ASM-16 modules may be added to expand the oper- ation to a plateau previously unimagined. The Intelligent Loop Interface - Expansion Board (ILI-S-E3/ ILI95-S-E3 provides the E3 Series control panel with two additional signaling line circuits. The layout is similar to the ILI-MB-E3/ILI95-MB-E3 with the exception that a number of components are omitted. It occupies one node on the Broadband network. E3 Series® and Velociti® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Features • IBC Seismic Certified. • Listed under UL ® Standard 864, 9th Edition. • UL Listed for smoke control (dedicated and non-dedi- cated) when properly configured. • FM/UL Listed for Pre-action/Deluge use. • Styles 4, 6, or 7* signaling line circuits. • Two to 244 SLCs each supporting 159 sensors and 159 modules. • 625K baud ARCNET communications using wire, fiber, or mixed configurations for installation flexibility. • High-speed 32 bit processor and 4100 event history log. • Advanced Boolean logic-based programming such as AND, OR, NOT, time delay and calendar functions configurable via computer programming. • Supports up to (16), ASM-16 addressable switch or ANU-48 LED driver modules per ILI-MB-E3/ILI95-MB-E3. • Two Class A, Style Z or Class B, Style Y, notification appliance circuits rated at 2.0 amps. per circuit. • Integral city connection. • Flexible 115,200 baud high speed RS-232 interface. • 40 character user-defined text per device. • Supports up to five LCD-7100/RAN-7100 displays and six LCD-E3 keyboard displays per ILI-MB-E3/ILI95-MB- E3. *Style 7 wiring requires the use of System Sensor M500X Isolator Modules. Expandable Emergency Evacuation System E3 Series GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0637 Rev. O page 2 of 2 www.gamewell-fci.com Description (Continued) Each ILI-MB-E3/ILI95-MB-E3 can support as many as six- teen ANU-48 LED Driver modules supporting hundreds of LEDs on a 3rd party graphic annunciator for remote annun- ciation. The ANU-48 modules may be installed in any Listed remote annunciator. It can be remotely located via an RS-485 serial interface. An array of cabinets allows for neat, compact, attractive installations. Installation The E3 Series expandable emergency evacuation system offers four cabinet size options. A typical cabinet includes a backbox, an inner door, and an outer door. The E3 Series cabinet assembly is a compact 19 3/8” (49 cm) wide wall- mounted enclosure. Cabinet A includes the following four options: • Cabinet A1 inner door mounted to the backbox. The backbox houses one NGA module. • Cabinet A2 inner door mounted to the backbox. The backbox houses one LCD-E3 module. • Two or three-bay inner door mounted to the backbox. The backbox typically houses one LCD-E3, or one NGA, and one or two ASM-16 modules. Cabinet B contains a space for the ILI-MB-E3/ILI95-MB-E3, PM-9/PM-9G modules and batteries set inside the back- box. Additional module options mounted on the backbox include the DACT-E3, and RPT-E3 or ILI-S-E3/ILI95-S-E3/ ANX. The 2-bay inner door houses one LCD-E3 module and one ASM-16 module. Both Cabinets C and D include the following: • Pre-assembled outer door that gives visibility to the fire fighter’s phone handset and a microphone voice messaging system. • Two inner door panel selections that may contain optional modules to meet the facility operation requirements. In the Cabinet B, C and D backboxes, the ANX appears in the same place as the ILI-MB-E3/ILI95-MB-E3 and PM-9/ PM-9G. For information on the installation instructions for any of the E3 Series cabinets, refer to the E3 Series® Expandable Emergency Evacuation Installation/Operating Manual Part Number: 9000-0574. Features (Continued) Velociti ® Intelligent Sensor Features: • Poll 318 devices in less than two seconds. • Activate up to 159 outputs in less than five seconds. • LED’s blink associated device address during Walk Test. • Fully digital, hi-precision protocol. • Up to 9 levels of sensitivity adjustment. • Pre-Alarm adjustable between 15 levels for both Alert and Action. • Day/night automatic sensing adjustment. • Sensitivity windows: - Ion .05 to 2% obscuration. - Photo 1 to 3% obscuration. - Laser .02 to 2% obscuration. - MCS Acclimate2F .5 to 4%, also self-adjustable options 1 to 2%, 2 to 3%, and 3 to 4%. - HARSH 1 to 3% obscuration. • Drift compensation. • Each Loop Card has its own integral processor providing maximum survivability on loss of any other component. SLC provides full response on loss of any other system processor. • Optional programmable switches can be configured to enable, disable or group any combination of output devices. • Integrated point or Grouped Cross Zoning allows for numerous devices installed at any location to cooperate and determine alarm condition. • Automatic detector sensitivity testing. • DIRTY and VERY DIRTY detector maintenance alerts. Specifications Operating Voltage:24 VDC Operating Temperature: Not to exceed the range of 32° to 120° F (0 to 49° C) Relative Humidity:Not to exceed 93% non-con- densing at 90° F (32° C) Ordering Information Part Number Description ILI-MB-E3 Intelligent Loop Interface-Main Board ILI95-MB-E3 Intelligent Loop Interface-Main Board ILI-S-E3 Intelligent Loop Interface-Expansion Board ILI95-S-E3 Intelligent Loop Interface-Expansion Board ANX-SR Addressable Node Expander-Single Ring ANX-MR-FO Addressable Node Expander-Multi-Ring Fiber Optic ANX-MR-UTP Addressable Node Expander-Multi-Ring Twisted-pair LCD-E3 LCD-E3, LCD Keypad Display RPT-E3-FO RPT-E3-UTP Network Repeater (fiber and twisted-pair) Network Repeater (twisted-pair only) DACT-E3 Digital Alarm Communicator Transmitter ANU-48 ANU-48 LED Driver Module ASM-16 Addressable Switch Module NGA LCD Network Graphic Annunciator PM-9 Power Supply Module PM-9G Power Supply Module LCD-7100 Remote LCD Display RAN-7100 Remote LCD Display For additional information on the cabinets, refer to the E3 Series Cabinets data sheet (Part Number: 9020-0649). Seismic Battery Bracket Kits For information on the types of Seismic Battery Bracket Kits that are available, the Seismic Battery Bracket Kit Part Numbers and the installation instructions, refer to the following documents: • Seismic Battery Bracket Installation Guide, P/N: 53839 • E3 Series Cabinets Data Sheet, P/N: 9020-0649 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0617 Rev. J page 1 of 2 Velociti® Series ASD-PL2F, ASD-PTL2F and ASD-PL2FR Analog, Addressable Photoelectronic Smoke Sensor APPROVED FM 3023594 SIGNALING 7272-1703:0121S1913 MEAApproved FDNY COA #:219-02-E Vol.VI Description The Gamewell-FCI Velociti® Series, analog address- able plug-in smoke sensors with integral communica- tion provide features that surpass conventional sensors. Sensitivity can be programmed in the con- trol panel software, and is continuously monitored and reported to the panel. Point ID capability allows each sensor’s address to be set, providing exact locations for selective maintenance when the cham- ber contamination reaches an unacceptable level. The ASD-PL2F photoelectric sensor’s unique optical sensing chamber is engineered to sense smoke pro- duced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-tem- perature thermal sensing on the ASD-PTL2F model. The Velociti® Series use a communication protocol that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and concen- trates on the single device. The net effect is a response speed up to five times greater than earlier designs. Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Ordering Information Part Number Description ASD-PL2F Analog, addressable photoelectronic smoke sensor ASD-PTL2F Analog, addressable photoelectronic smoke sensor with thermal sensing ASD-PL2FR Analog, addressable photoelectronic smoke sensor used with the DNR duct base when the remote test is required. Features • Sleek, low-profile design. • Visual rotary, decimal switch addressing (01-159). • Built-in functional test switch activated by an external magnet. • Bicolor LEDs flash green whenever the sensor is addressed, and light steady red on alarm.* • Optional relay, isolator, or sounder bases. • Low standby current. • Analog addressable communication. • Stable communication technique with noise immunity. • Optional remote, single-gang LED Indicator (RA100Z). • Compatible with Gamewell-FCI analog addressable panels. Note: *Only the red LED is operative in panels that do not operate in Velociti® mode. ASD-PL2FRASD-PL2F/ASD-PTL2F GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0617 Rev. J page 2 of 2 www.gamewell-fci.com Installation ASD-PL2F plug-in sensors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: •4.0" (10.2 cm) square box. •3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box. • Single-gang box (except relay or isolator bases). • With B200S or B200SR base, mounted on a 4.0" (10.2 cm) octagonal or square box. • With B224RB or B224BI base, mounted on a 3.5" (8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or square box. NOTE: Because of the inherent supervision provided by the SLC, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring. Sensor Spacing Gamewell-FCI recommends that the spacing sensors be used in compliance with NFPA 72. Specifications ASD-PL2F, ASD-PTL2F, ASD-PL2FR: Dimensions:2.1” (5.1 cm) height Diameter:4.1” (10.4 cm) installed in the B501 base 6.1” (15.5 cm) installed in the B210LP base Shipping Weight:5.2 oz. (147 g) Operating Temperature: ASD-PL2F: 32° F to 120° F (0° C to 49° C) ASD-PTL2F: 32° F to 100° F (0° C to 38° C) UL®-Listed Velocity Range: 0-4000 ft./min. (1,219.2 m/min.), suitable for installation in ducts. Relative Humidity: 10-93% (non-condensing) Thermal Ratings:Fixed-temperature setpoint 135° F (57° C) Electrical Specifications Voltage Range: 15 – 32 volts DC peak Standby Current: (max. avg.): .0003 A @ 24 VDC (One communication every 5 seconds with LED blink enabled). Maximum Alarm- Current: .0065 A @ 24 VDC (LED) lit). Bases and Options B501 Plug-in sensor base without flange Dimensions:4.1” (10.4 cm) diameter B210LP Flanged mounting base Dimensions:6.1” (15.5 cm) diameter B210LPBP Flanged mounting base bulk pack Dimensions:6.1” (15.5 cm) diameter B224RB Relay Base Plug-in sensor base with auxiliary relay, SPDT, rated 2 amps @ 30 VDC (resistive). Screw terminals: Up to 14 AWG (2.0 mm2) 2 coil latching relay 1 Form C contact UL/CSA Rating: 0.9 A @ 125 VAC, inductive 0.9 A @ 110 VDC, inductive 3 A @ 30 VDC, resistive Dimensions:6.1” (15.5 cm) diameter Maximum: 25 devices between isolator bases. B200S Intelligent sensor sounder base Dimensions:6.875” (17.5 cm) diameter B200SR Standard sounder base, UL 8649th Edition compliant, ULC Listed Dimensions:6.875” (17.5 cm) diameter RA100Z Remote LED Annunciator BCK-200 Black detector covers (box of 10) DNR Duct smoke housing GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2016 by Honeywell International Inc. All rights reserved www.gamewell-fci.com 9021-60931 Rev. A page 1 of 3 Indoor Selectable-Output Speaker Strobes and Dual-Voltage Evacuation Speakers for Wall Applications L-Series Indoor Wall Speaker Strobes and Speakers APPROVED FM SIGNALING PENDING Description The L-Series indoor selectable-output speaker strobes and dual-voltage evacuation speakers offer a modern, aes- thetic plug-in design that reduce costly ground faults. The universal mounting plate can be used in wall installation applications and its flexible design enables the Installer to easily perform the following: • Pre-wire mounting plates. • Dress the wires. • Confirm wiring continuity before the Installer plugs-in the speakers. This product includes a protective plastic cover which shields exposed speaker components and prevents nicked wires. These devices enable faster installations by providing instant feedback to the Installer to ensure the following: • The wiring is properly connected. • The rotary switches are set to the selected voltage and power settings. • The 7 field-selectable candela settings are configured for wall speaker strobes. The low total harmonic distortion of the speaker offers both high-fidelity and high-volume sound output so that it can be used in high ambient noise applications. L-Series makes installation easy To install the L-Series speakers or speaker strobe, do the following: 1. Attach a universal mounting plate to a 4 x 4 x 2 1/8 inch backbox. Flush-mount applications do not require an extension ring. 2. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. 3. To attach the speaker or speaker strobe to the mount- ing plate, insert the product tabs into the mounting plate grooves. 4. Hinge the device into position to lock the product pins into the mounting plate terminals. 5. A catch will temporarily hold the device in place until you secure the device with a captured mounting screw. L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General The L-Series speaker and speaker strobes shall mount to a 4 x 4 x 2 1/8-inch backbox. A universal mounting plate shall be used for the mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Features • Includes a plug-in feature to reduce ground faults and a protective cover to shield speaker components. • Contains a universal mounting plate with an on-board shorting spring that is used to test the wiring continuity before an installation. • No extension ring required. • Field-selectable candela settings on wall units: - 15 - 30 - 75 - 95 - 110 - 135 - 185 • Uses an automatic selection of 12- or 24-volt operation at 15 and 30 candela. • Provides a rotary switch that simplifies the field selection of speaker voltage (25) and 70.7 VRMS) and the follow- ing power settings: – 1/4 watt – 1/2 watt – 1 watt – 2 watts • Offers speakers with both a high-fidelity and a high-volume sound output. • Compatible with the System Sensor synchronization protocol. • Supports electrical compatibility with the existing SpectrAlert and the SpectrAlert Advance products. • Designed with a tamper-resistant construction. • Built with an updated modern design. Wall Speaker Strobe GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 page 2 of 3 www.gamewell-fci.com 9021-60931 Rev. A UL Current Draw Data Table 1 lists the UL maximum strobe current draw. Table 2 lists the speaker strobe sound outputs. Table 3 lists the speaker sound outputs. L-Series Speaker and Speaker Strobe Specifications (Continued) Architectural/Engineering Specifications (Continued) General (Continued) Also, the L-Series speaker strobes, when used with the Sync•Circuit. Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When it is used with the Sync•Circuit Module, either of the following may occur. • 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. • 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. The Indoor L-Series products shall operate between 32° F and 120°F from a regulated DC, or full-wave rectified, unfil- tered power supply. Wall-mount speaker strobes shall include the following field-selectable candela settings: - 15 - 30 - 75 - 95 - 110 - 135 - 185 Speaker The speaker shall be an L-Series model _______ dual- voltage transformer speaker capable of operating at 25.0 or 70.7 nominal VRMS. It should be listed to UL Standard 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe Combination The speaker strobe shall be an L-Series model __________ listed to UL Standard 1480 and UL Standard 1971 and be approved for fire protective signaling sys- tems. The speaker shall be capable of operating at 25.0 or 70.7 nominal VRMS selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/ reflector system. Synchronization Module The module shall be a Sync•Circuit model MDL3 listed to UL Standard 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 4 11/16 x 4 11/16 x 21/8-inch backbox. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy-chaining two or more synchronization modules together will syn- chronize all the zones they control. The module shall not operate on a coded power supply. Physical Specifications Operating Temperature:32°F to 120°F(0°C to 49°C) Humidity Range:10 to 93% non-condensing Dimensions, Wall-Mount: Length Width Depth SP Speaker:6.5 in, 165 mm 5 in, 127 mm 2.3 in, 58 mm With Surface Mount Backbox: 6.6 in, 168 mm 5.1 in, 130 mm 3.2 in, 82 mm SPS Speaker/Strobe (including lens and speaker): 6.5 in, 165 mm 5.0 in, 127 mm 2.3 in, 58 mm With Surface Mount Backbox:6.6 in, 168 mm 5.1 in, 130 mm 4.55 in, 116 mm Electrical/Operating Specifications Nominal Voltage (speakers):25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers):50 VDC Strobe Flash Rate:1 flash per second Nominal Voltage (strobes):Regulated 12 VDC or Regulated 24 VDC/FWR Operating Voltage Range (includes fire alarm panels with built-in sync):8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MDL3 Sync Module: 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V(24 V nominal) Frequency Range:400 to 4,000 Hz Power:¼, ½, 1, 2 watts Candela 8-17.5 Volts 16-33 Volts FWRDC DC 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 Table 1: UL Max. Strobe Current Draw (mA RMS) Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 77 77 1/2 W 80 80 1 W 83 83 2 W 86 86 Table 2: Sound Output Speaker Strobe Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 79 79 1/2 W 82 82 1 W 83 85 2 W 88 88 Table 3: Sound Output Speaker GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60931 Rev. A page 3 of 3 Dimensions Figure 1 shows the speaker dimensions. Figure 2 shows the speaker dimensions. Surface Mounting Figure 3 illustrates the wall-mount speaker and speaker strobes with the SBBSPRL surface mount backbox. Figure 1 Wall-Mount Speaker Figure 2 Wall-Mount Speaker Strobe Figure 3 Wall-Mount Speaker Strobe with SBBSPRL Surface Mount Backbox L-Series Ordering Information Speakers and Speaker Strobes Wall Mount Part Number Description SPWL White, Speaker only SPRL Red, Speaker only SPSWL White, Speaker Strobe SPSRL Red, Speaker Strobe SPSRL-P Plain Speaker Strobe SPSWL-P White, Plain Speaker Strobe SPSWL-ALERT White, Speaker Strobe, Amber Lens SPSWL-CLR-ALERT White Speaker Strobe Clear Lens SPSRL-SP White, Speaker Strobe, Fuego Accessories RFPW White, 7 in × 9.5 in Retrofit Plate RFP Red, 7 in × 9.5 in Retrofit Plate SBBSPW White, Surface Mount Back Box for Speakers and Speaker Strobes SBBSPR Red, Surface Mount Back Box for Speakers and Speaker Strobes TRW White, Wall Mount Trim Ring TR Red, Wall Mount Trim Ring Notes: All -P models have a plain housing (no “FIRE” marking on the cover). GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2016 by Honeywell International Inc. All rights reserved www.gamewell-fci.com 9021-60930 Rev. A page 1 of 3 Indoor Selectable-Output Speaker Strobes and Dual Voltage Evacuation Speakers for Ceiling Applications L-Series Indoor Ceiling Speaker Strobes and Dual Speakers APPROVED FM SIGNALING PENDING Description The L-Series indoor selectable-output speaker strobes and dual-voltage evacuation speakers offer a modern, aes- thetic plug-in design that reduce costly ground faults. The universal mounting plate can be used in ceiling applica- tions and its flexible design enables the Installer to easily perform the following: • Pre-wire mounting plates. • Dress the wires. • Confirm wiring continuity before the Installer plugs-in the speakers. In addition, this product includes a protective plastic cover which shields exposed speaker components and prevents nicked wires. These devices enable faster installations by providing instant feedback to the Installer to ensure the following: • The wiring is properly connected. • The rotary switches are set to the selected voltage and power settings. • The 7 field-selectable candela settings are configured for wall speaker strobes. The low total harmonic distortion of the SP speaker offers both high-fidelity and high-volume sound output so that it can be used in high ambient noise applications. L-Series makes installation easy To install the L-Series speakers or speaker strobe, do the following: 1. Attach a universal mounting plate to a 4 x 4 x 2 1/8 inch backbox. Flush-mount applications do not require an extension ring. 2. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. 3. To attach the speaker or speaker strobe to the mount- ing plate, insert the product tabs into the mounting plate grooves. 4. Hinge the device into position to lock the product pins into the mounting plate terminals. 5. A catch temporarily holds the device in place until you secure the device with a captured mounting screw. L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General The L-Series speaker and speaker strobes shall mount to a 4 x 4 x 2 1/8-inch backbox. A universal mounting plate shall be used for the mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Features • Includes a plug-in feature and protective cover to reduce ground faults. • Contains a universal mounting plate with an on-board shorting spring that is used to test the wiring continuity before an installation. • No extension ring required. • Field-selectable candela settings on ceiling units: - 15 - 30 - 75 - 95 - 115 - 150 - 177 • Uses an automatic selection of 12- or 24-volt operation at 15 and 30 candela. • Provides a rotary switch that simplifies the field selection of speaker voltage (25) and 70.7 VRMS) and the follow- ing power settings: – 1/4 watt – 1/2 watt – 1 watt – 2 watts • Offers speakers with both high-fidelity and high-volume sound output. • Compatible with the System Sensor synchronization protocol. • Supports electrical compatibility with the existing SpectrAlert and the SpectrAlert Advance products. • Designed with a tamper-resistant construction. • Built with an updated modern design. Ceiling Speaker Strobes GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 page 2 of 3 www.gamewell-fci.com 9021-60930 Rev. A UL Current Draw Data Table 1 lists the UL maximum strobe current draw. Table 2 lists the ceiling mount speaker sound outputs. Table 3 lists the ceiling-mount speaker strobe sound out- puts. L-Series Speaker and Speaker Strobe Specifications (Continued) Architectural/Engineering Specifications (Continued) General (Continued) Also, the L-Series speaker strobes, when used with the Sync•Circuit. Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When these devices are used with the Sync•Circuit Module, either of the follow- ing may occur. • 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. • 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. The Indoor L-Series products shall operate between 32° F and 120°F from a regulated DC, or full-wave rectified, unfil- tered power supply. Speaker strobes shall have the follow- ing field-selectable candela settings: - 15 - 30 - 75 - 95 - 115 - 150 - 177 Speaker The speaker shall be an L-Series model _______ dual- voltage transformer speaker capable of operating at 25.0 or 70.7 nominal VRMS. It should be listed to UL Standard 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe Combination The speaker strobe shall be an L-Series model __________ listed to UL Standard 1480 and UL Standard 1971 and be approved for fire protective signaling sys- tems. The speaker shall be capable of operating at 25.0 or 70.7 nominal VRMS selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/ reflector system. Synchronization Module The module shall be a Sync•Circuit model MDL3 listed to UL Standard 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will syn- chronize all the zones they control. The module shall not operate on a coded power supply. Physical Specifications Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity Range: 10 to 93% non-condensing Dimensions,Ceiling-Mount: Diameter Depth SPC Speaker 6.8 in, 173 mm 1.0 in, 25 mm With Surface Mount Backbox 6.9 in, 176 mm 3.5 in, 89 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in, 73 mm With Surface Mount Backbox 6.9 in, 176 mm 5.37 in,136 mm Electrical/Operating Specifications Nominal Voltage (speakers): 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers): 50 VDC Strobe Flash Rate: 1 flash per second Nominal Voltage (strobes): Regulated 12 VDC or Regulated 24 VDC/FWR Operating Voltage Range (includes fire alarm panels with built-in sync): 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MDL3 Sync Module: 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range Frequency Range: 400 to 4,000 Hz Power: ¼, ½, 1, 2 watts Candela 8-17.5 Volts 16-33 Volts FWRDC DC 15 87 41 60 30 153 63 86 75 NA 111 142 95 NA 134 164 115 NA 158 191 150 NA 189 228 177 NA 226 264 Table 1: UL Max. Strobe Current Draw (mA RMS) Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 79 79 1/2 W 82 82 1 W 85 85 2 W 88 88 Table 2: Ceiling-Mount Speaker Sound Output Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 77 77 1/2 W 80 80 1 W 83 83 2 W 86 86 Table 3: Ceiling-Mount Speaker Strobe Sound Output GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60930 Rev. A page 3 of 3 Dimensions Figure 1 shows the speaker dimensions. Figure 2 shows the speaker dimensions. Surface Mounting Figure 3 illustrates the ceiling-mount speaker and speaker strobes with the SBBCR/SBBCWL surface mount back- box. Figure 1 Speaker Dimensions Figure 2 Speaker Dimensions Figure 3 Ceiling-Mount Speaker and Speaker Strobe with SBBCRL/SBBCWL Surface Mount Backbox L-Series Ordering Information SpectrAlert Speakers and Strobes Ceiling Mount Part Number Description SPCWL White Speaker only SPCRL Red Speaker only SPSCWL White Speaker Strobe SPSCRL Red Speaker Strobe SPSCWL-P Plain, Speaker Strobe SPSCWL-SP Fuego, Speaker Strobe SPSCWL-CLR-ALERT Alert, Speaker Strobe,Clear Lens Accessories SBBCWL White, Universal Ceiling Surface Mount Back Box SBBCRL Red, Universal Ceiling Surface Mount Back Box TRC-2W White, Universal Ceiling Trim Ring TRC-2 Red, Universal Ceiling Trim Ring GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2010 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9021-60521 Rev. B page 1 of 2 HPFF8 NAC Expander/Power SupplyDescription The Gamewell-FCI, HPFF8 is a Notification Appliance Cir- cuit (NAC) expansion panel designed to extend the power capabilities of existing NACs and provide power for the auxiliary devices. The HPFF8 connects to any 12 or 24V Fire Alarm Control Panel (FACP) or stand alone. The HPFF8 is available in 8.0 amps. It provides regulated and filtered 24VDC power to each of the four NACs and an auxiliary output. The NAC outputs are rated at 3.0 amps each (the total output cannot exceed 8.0 amps). The auxil- iary output is rated at 2.0 amps. This output is continuously supplied, even in alarm, and therefore must be taken into account for power supply loading and battery size calcula- tions. The NAC outputs may be configured as any of the follow- ing: • Four Class B (Style Y) • Two Class A (Style Z) • Two Class B and one Class A • Four Class A with the optional HPP31076 Class A adapter installed These power supplies contain an internal Battery charger capable of charging up to 26.0 amp-hour (AH) batteries. The HPFF8 is mounted in lockable wall cabinet units that can accommodate up to two (2), 18AH batteries. A multi- pack option allows for up to four chassis mount units installed in a single lockable SBB-D4 enclosure. These chassis mount units have a "CM" suffix, HPFF8CM and can accommodate two 12AH batteries. Power supplies are available in either 120VAC/60 Hz or 240VAC/50 Hz. One of the most challenging aspects of a retrofit applica- tion is locating the existing End-of-Line (EOL) resistor. In these applications that have EOL values, other than the 3.9k normally used with the HPFF8, a single resistor matching the existing EOL can be used as a reference for all the outputs. This feature speeds the installation and the system checkout, because the actual EOL does not need to be located and changed in the circuit. The reference resistor must be within the range of 1.9k to 25k. Features • Four (4) supervised notification application circuits (NACs) capable of supplying +24VDC at 3.0 amp maximum each • NAC output circuits may be configured as any of the following: - Four Class B (Style Y) - Two Class B & one Class A - Two Class A (Style Z) - Four Class A with the optional HPP31076 Class A adapter installed • Four field-programmable operational modes • 2.0 amp auxiliary continuously supplied output • Two (2) fully supervised input/output control circuits • Temporal coding and sync protocols compatible with the following notification appliance brands: - System Sensor - Faraday - Gamewell - Amseco - Cooper-Wheelock - Gentex • Supervised AC input, battery voltage, auxiliary output, charger, and earth ground faults • Trouble indication for supervision of the following: - NAC circuits - Auxiliary output - AC input - Charger - Battery voltage - Open contacts in the initiat- ing device signal inputs (for FACP trouble notification) - Earth ground faults by individual status LED's • Separate Trouble and AC Fail Form-C relay Contacts HPFF8 An ISO 9001-2000 Company 7315-1637:0102 SIGNALING S24562 FM APPROVED GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60521 Rev. B page 2 of 2 www.gamewell-fci.com Features (Continued) • The Trouble Form-C relay contacts selectable for imme- diate or a 2 hour delay with AC failure • 26 AH battery charger capability; the wall cabinet supports two 12V 18AH batteries, while the multi-pack equipment cabinets supports two 12V 12AH batteries. • NAC Overload protection and indication • Up to four chassis mount units (HPFF8CM) can be installed in the SBB-D4 backbox • Wall mount units can be configured to internally house the following: - one AOM-2SF single control module - one AOM-2R single relay module Specifications Primary Input Power:120VAC/60Hz, 3.6A or 220VAC/50Hz, 1.5A Secondary Power:24 volt operation: two (2), 7-24 AH batteries Battery Charging Capacity:Up to 26 AH batteries mounted Battery Space: HPFF8 Cabinet:Up to two 18AH batteries SBB-D4 Cabinet:Up to two 12AH batteries per supply Total Output Power:8.0A max Standby Current: 0.030 A Auxiliary Power Output:0.15A under all conditions 2.0A if load is removed dur- ing operation (external relay or AC Fail Relay is required) Specifications (Continued) NAC Output Ratings:24VDC fully regulated, 3.0A max per circuit (8.0A total) End-of-Line Resistor Range: 2K to 25k ohm, ½ watt Common Trouble Relay/AC Fail Relay:2.0A at 28VDC or 120VAC Input Control Circuit:16-30VDC @ 5mA min. Temperature Rating:32°F to 120°F (0°C to 49°C Relative Humidity:10% to 93% non-condensing Cabinet Dimensions: HPFF8 Cabinet:16.65” W x 19.0” H x 5.2” D (42.29 W x 48.26 H 13.23 D cm) SBB-D4 Cabinet:24” W x 45.9” H x 5.15” D (60.96 W x 116.52 H x 13.1D cm) Ordering Information Part Number Description HPFF8 8A fire rated power supply operating at 120VAC/60 Hz. Unit includes red enclosure with HPP lock and key HPFF8CM 8A fire rated power supply - chassis mounted operating at 120VAC/60 Hz. Unit includes mounting hardware for installation in the SBB-D4 enclosure HPFF8E 8A fire rated power supply operating at 240VAC/50 Hz HPFF8CME 8A fire rated power supply chassis mounted operating at 240VAC/50 Hz HPP31076 Class A (Style Z) NAC module FCI-VDR-D4 Vented door, PK-625 lock and key for SBB-D4 backbox, black SBB-D4 Backbox, accepts up to 4 chassis, black Standby 0.075 A Alarm 1.044 A Qty Draw Non-Alarm Qty Draw Alarm 1 x 0.07500 0.07500 1 x 0.20600 0.20600 2 x 0.00000 0.00000 2 x 0.06600 0.13200 5 x 0.00000 0.00000 5 x 0.06600 0.33000 4 x 0.00000 0.00000 4 x 0.09400 0.37600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.83800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.03000 0 x 0.03700 0 x 0.00850 0 x 0.00400 0 x 0.00650 0 x 0.05000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #3 Totals (Max 3 Amps): 4. . SPSW15 SPSCW15 SPSCW30 NAC #2 Totals (Max 3 Amps): Device 1.044 System Current Draw - HPFF8 Total Current Secondary Alarm CurrentSecondary Non-Alarm Current 1. System Modules 1. L1 HPFF8 Main Circuit Board Other compatible devices Other compatible devices Total Non-Alarm Load: 2. . NAC #1 Totals (Max 3 Amps): NAC #4 Totals (Max 3 Amps): 3. . TB4 Totals (Max 2 Amps): Other compatible devices 7. Compatible Devices not listed 0.075 6. Auxiliary Power PR-3 FIRERAY5000 EVM E3SMRCO/E3SA Auxiliary Device Total Alarm Load: Protected Premises:Date:9/1/2017 Address: City:State:UT Zip:83460 Prepared By:Phone:801.468.8300 Address:Email: City:State:UT Zip:84115 Secondary Load Requirements 4.63 Amp Hours Total (AH) 3.60 0.26 3.86 x 1.2 4.63 AH 8 Amp Hours TRUE Current Draw Secondary Standby Load Select batteries from the list below. Battery Selection 8.0 AH BAT-1270 Battery (12 volt) Derating factor Secondary Load Requirements Total Secondary Load Secondary Alarm Load x1.044 A Required Alarm Time (hours) 0.250 hours Time (hours) Required Standby Time 48 hoursx Total Secondary Load from the calculation table below. 0.075 A 1481 S Major Street Office@nelsonfire.com Salt Lake City Secondary Power Requirements BYU-Idaho Kimball Bldg Lvl 1 Remodel 525 South Center St. 1625 Rexburg Nelson Fire Systems HPFF8 Power Supply Page 2 of 131 Battery Distribution Chart Comments 3.37 4.32 0.31 3. The selected batteries (8AH) are within the charger range of this power supply (7-26AH). Spare Battery Capacity Secondary Standby Load 2. Selected battery size meets secondary load requirements. Battery Selection (AH) - Secondary Load Requirements (AH) Secondary Standby Load (AH) * Derating Factor 1. Batteries will fit in the FACP cabinet. Secondary Alarm Load (AH) * Derating FactorSecondary Alarm Load Shows amp-hour distribution of your selections. Spare Battery Capacity 42% Secondary Standby Load 54% Secondary Alarm Load 4% Spare Battery Capacity Secondary Standby Load Secondary Alarm Load Page 3 of 131 Honeywell Online Tools For Fire Version 2.0.11 PROJECT DETAILS Project Name : BYU-Idaho Kimball Building - Lvl 1 Remodel Project Code : Project Location : 525 South Center St. 1625, Rexburg, Idaho, 83460 PREPARED BY Nelson Fire Sytems Voltage Drop Calculations POWER SOURCE : FF8  MODEL NUMBER : HPFF8 BRAND : HPP CLASS A 20.4 VOLTS   DC POWER CIRCUIT: L1   3 Amps   14 AWG 11 DEVICES 18.1 % (0.543) AMPS USED 4.59 % (0.937) VOLTAGE DROP #MODEL CANDELA PATTERN VOLUME TONE CURRENT (amps) DISTANCE FROM PREVIOUS DEVICE (Ft) 12 AWG 14 AWG 16 AWG 18 AWG 1 SPSCWL 30 0.063 20 19.808 19.463 18.907 18.023 2 SPSCWL 30 0.063 30 19.816 19.475 18.926 18.054 3 SPSWL 15 0.043 45 19.839 19.511 18.984 18.146 4 SPSCWL 15 0.041 25 19.856 19.538 19.027 18.214 5 SPSWL 15 0.043 40 19.890 19.592 19.112 18.350 6 SPSCWL 30 0.063 30 19.921 19.640 19.189 18.473 7 SPSCWL 15 0.041 45 19.978 19.731 19.333 18.703 8 SPSCWL 30 0.063 30 20.021 19.799 19.442 18.876 9 SPSCWL 15 0.041 30 20.072 19.879 19.570 19.080 10 SPSCWL 15 0.041 20 20.109 19.938 19.664 19.229 11 SPSCWL 15 0.041 20 20.149 20.002 19.766 19.391 Voltage Drop 0.592 0.937 1.493 2.377 Page: 1 09/01/2017 13:48:41 PM