HomeMy WebLinkAboutPLANS FIRE ALARM - 17-00435 - 525 S Center St - BYUI - Kimball Ste 130 RemodelBYU— IDAHO KIMBALL BUILDING LEVEL I SUITE 130 REMODEL FIRE ALARM SYSTEM INDEX OF DRAWINGS SYMBOL DESCRIPTI❑N PART NUMBER MOUNTING REQUIREMENT PAGE SHEET # DESCRIPTI❑N ss SPEAKER/STROBE— WALL SPSWL 4 SQ. 2-1/8' DEEP BOX MINIMUM w/1-1/2' EXT. RING ss� SPEAKER/STR❑BE— CEILING FA—C-01 PROJECT COVER SHEET / INDEX OF DRAWINGS NELSON FIRE SYSTEMS 2 FA—R-01 FIRE ALARM BUILDING RISER DIAGRAM / MATRIX NELSON FIRE SYSTEMS 3 E41 FA -1-01 LEVEL 1— ADDRESSABLE CIRCUITS NELSON FIRE SYSTEMS FA -1-02 LEVEL 1— N❑TIFICATI❑N CIRCUITS NELSON FIRE SYSTEMS DEVICE SCHEDULE SYMBOL DESCRIPTI❑N PART NUMBER MOUNTING REQUIREMENT ® SMOKE DETECTOR w/BASE ASD—PL2F w/B210LP 3/0 MUD RING ss SPEAKER/STROBE— WALL SPSWL 4 SQ. 2-1/8' DEEP BOX MINIMUM w/1-1/2' EXT. RING ss� SPEAKER/STR❑BE— CEILING SPSCWL 4 SQ. 2-1/8' DEEP BOX MINIMUM w/1-1/2' EXT. RING F9 FIRE ALARM CONTROL UNIT EXISTING EXISTING TO REMAIN ® TRANSPONDER EXISTING EXISTING TO REMAIN V Z J Lf') W N o W m W N _ H J[fIo U) J O LL ao U) Q to Q M — Z — W Lu YI—U�Q _ J =oral—mQ — D X W Q O w � �wcn�- > Ln W N >- J Lo m N F S NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: JPK DESIGNED BY: XXXX APPROVED BY: TFT DATE: 8/18/2017 SCALE: (ANSI 8) 1/16'=1' PROJECT NO: XXXX REV NO: XXXX DRAWING NAME: BYU-I KIMBALL C.DWG FIRE ALARM SYSTEM COVER SHEET PAGE FA -C-01 LEVEL 1 FIRE ALARM INPUT/OUTPUT MATRIX SYSTEM OUTPUTS FRCP ATION NOTIFICATION FIRE SAFETY CONTROL REPORTING ra �i r qra o� Ha 5 oPb g 12 24 �yrcyrc SYSTEM INPUTS�W atir JJJ ZINC <0f LEVEL 1- SMOKE DETECTORS • • • • • • • • • • LOSS OF POWER ANY PANEL OR NAC • • LOW BATTERY CONDITMNS • _ _ • ji OPEN CIRCUIT CONDITIONS • • GROUND FAULTS •i I I I I• SP1 -1 SP1 -2 SP1 -3 SP1 -4 SP1 -5 SP1 -6 SP1 -7 SP1 -8 SP1 -9 SP1 -10 SP1 -11 1/2W 1/2W 1/2W 1/2W 1/2W 1/2W 1/2W 1/2W 1/2W 1/2W 1/2W Ll -1 Ll -2 Ll -3 Ll -4 Ll -5 Ll -6 Ll -7 Ll -8 Ll -9 Li -10 Li -11 SPEAKER CIRCUIT 30cd 30cd 15cd 15cd 15cd 30cd 15cd 30cd 15cd 15cd 15cd 1 PAIR #14'S TWISTED SHIELDED (X) STROBE CIRCUITS 2 #14'S TRANSPONDER EXISTING (1) HP-FF8 D❑ NO USE SHIELDED WIRE ON ADDRESSABLE CIRCUIT Z J U-) W N p p \0 1:F- � Lu M W N F- -i Of c N7 N J p Lu cp } Q N7 F - p (n m — Z — Lu Lu - (if H UOf Q _ — � x Lu Q O W Of � Lu LL Lu (V >- J Lo m NFS NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: JPK DESIGNED BY: XXXX APPROVED BY: TOT DATE: 8/18/2017 SCALE: (ANSI B) 1/16" = I' PROJECT NO: XXXX REV N0: XXXX DRAWING NAME: BYU-I KIMBALL R.DWG FIRE ALARM SYSTEM RISER DIAGRAM / MATRIX PAGE: FA -R-01 GENERAL NOTES: I. INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND ALL OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. CLASS "B" WIRING IS REQUIRED. 2. WIRING DEPICTED ON THESE PLANS IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLAN. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITIONS ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER VOLTAGE CABLES ARE IN THE SAME RACEWAY. 3. POWER -LIMITED AND NONPOWER -LIMITED CIRCUIT HARING MUST REMAIN SEPARATED IN CABINET. ALL POWER -LIMITED CIRCUIT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NONPOWER -LIMITED CIRCUIT WIRING. FURTHERMORE, ALL POWER -LIMITED AND NONPOWER -LIMITED CIRCUIT WIRING MUST ENTER AND EXIT THE CABINET THROUGH DIFFERENT KNOCK OUTS AND/OR SEPARATE CONDUITS. 4. SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN. 5 -LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. 6. PROVIDE SYNCHRONIZATION OF ALL VISUAL NOTIFICATION APPLIANCE CIRCUITS. PROVIDE ALL REQUIRED SYNC MODULES. A MULTI -SYNC MODE SLAVE CONNECTION BETWEEN ALL SYNC MODULES. 7.ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM CONDUIT. 110V OR HIGHER VOLTAGE CABLES ARE NOT ALLOWED IN FIRE ALARM CONDUIT. 8. DO NOT USE SHIELDED WIRE ON ADDRESSABLE CIRCUITS. 9. FIRE ALARM CIRCUITS NEED TO BE FREE OF GROUNDS, FAULTS, AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM EQUIPMENT. IO.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A FIRE ALARM CONTROL UNIT, POWER SUPPLY, OR ANNUNCIATOR. 11 DEDICATED 120 VAC CIRCUITS WILL BE MARKED AS "FIRE ALARM CIRCUIT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS FOR THESE CIRCUITS WILL BE RED IN COLOR AND THEIR LOCATION WILL BE NOTED AT EACH CONTROL UNIT. 4 yl 5' 10' 15' 20' WIRE SCHEDULE NOTE DESCRIPTI❑N WIRES A SPEAKER CIRCUIT 1 PAIR #14'S TWISTED/SHIELDED B STROBE CIRCUIT 2 #14'S SYSTEM NOTES: <T> TO EXISTING TRANSPONDER <g> RELOCATE, REINSTALL AND RECONNECT EXISTING SMOKE DETECTORS JL.url LEVEL 1 (9) � } W Jx n Z Z F O O o Z o Er z O ,n w a 3 3 � V Oln NaOZQ03 o u ECNa -w�W-N xdzwa aWZF Z wo�o��w�F o aooFF�zo z N W N N m p p m J m Z Z Z Q Z N 0 2 W z ~ Q W Q F EC Z " Z W w w o 0 r .O?z - W O D o w Z Z z- � W ZD F J a d J t 7 Z J Z Q � U a3wo� F ..... V Z W W W U1W O w woo 2 x W W zz <w -F ..Q C7 z J L0 LL (V p 10 Z) z H 'o Lu M Lu N _ H J O LU < Io l— cn m—z-3r Lu Lu - of F- U Q J 0NP—mQ _ z:) X LL Q O u1 CY Ln W C/) Of E I > Lo O Lu (V >- J Lo m N FS NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: JPK DESIGNED BY: XXXX APPROVED BY: TDT DATE: 8/18/2017 SCALE: (ANSI B) 1/16" = I' PROJECT NO: XXXX REVISION NO: XXXX DRAWING NAME: BYU-I KIMBALL MAIN.DWG NELSON FIRE SYSTEMS LEVEL I SUITE 130 ADDRESSABLE PAGE: FA -1-01 DEVICE LEGEND SYMBOL DESCRIPTI❑N Q SMOKE DETECTOR ss SPEAKER/STROBE— WALL ssc SPEAKER/STROBE— CEILING Ac FIRE ALARM CONTROL UNIT RA TRANSPONDER PANEL JL.url LEVEL 1 (9) � } W Jx n Z Z F O O o Z o Er z O ,n w a 3 3 � V Oln NaOZQ03 o u ECNa -w�W-N xdzwa aWZF Z wo�o��w�F o aooFF�zo z N W N N m p p m J m Z Z Z Q Z N 0 2 W z ~ Q W Q F EC Z " Z W w w o 0 r .O?z - W O D o w Z Z z- � W ZD F J a d J t 7 Z J Z Q � U a3wo� F ..... V Z W W W U1W O w woo 2 x W W zz <w -F ..Q C7 z J L0 LL (V p 10 Z) z H 'o Lu M Lu N _ H J O LU < Io l— cn m—z-3r Lu Lu - of F- U Q J 0NP—mQ _ z:) X LL Q O u1 CY Ln W C/) Of E I > Lo O Lu (V >- J Lo m N FS NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: JPK DESIGNED BY: XXXX APPROVED BY: TDT DATE: 8/18/2017 SCALE: (ANSI B) 1/16" = I' PROJECT NO: XXXX REVISION NO: XXXX DRAWING NAME: BYU-I KIMBALL MAIN.DWG NELSON FIRE SYSTEMS LEVEL I SUITE 130 ADDRESSABLE PAGE: FA -1-01 GENERAL NOTES: I. INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND ALL OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. CLASS "B" WIRING IS REQUIRED. 2. WIRING DEPICTED ON THESE PLANS IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLAN. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITIONS ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER VOLTAGE CABLES ARE IN THE SAME RACEWAY. 3. POWER -LIMITED AND NONPOWER -LIMITED CIRCUIT HARING MUST REMAIN SEPARATED IN CABINET. ALL POWER -LIMITED CIRCUIT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NONPOWER -LIMITED CIRCUIT WIRING. FURTHERMORE, ALL POWER -LIMITED AND NONPOWER -LIMITED CIRCUIT WIRING MUST ENTER AND EXIT THE CABINET THROUGH DIFFERENT KNOCK OUTS AND/OR SEPARATE CONDUITS. 4. SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN. 5 -LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. 6. PROVIDE SYNCHRONIZATION OF ALL VISUAL NOTIFICATION APPLIANCE CIRCUITS. PROVIDE ALL REQUIRED SYNC MODULES. A MULTI -SYNC MODE SLAVE CONNECTION BETWEEN ALL SYNC MODULES. 7.ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM CONDUIT. 110V OR HIGHER VOLTAGE CABLES ARE NOT ALLOWED IN FIRE ALARM CONDUIT. 8. DO NOT USE SHIELDED WIRE ON ADDRESSABLE CIRCUITS. 9. FIRE ALARM CIRCUITS NEED TO BE FREE OF GROUNDS, FAULTS, AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM EQUIPMENT. IO.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A FIRE ALARM CONTROL UNIT, POWER SUPPLY, OR ANNUNCIATOR. 11 DEDICATED 120 VAC CIRCUITS WILL BE MARKED AS "FIRE ALARM CIRCUIT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS FOR THESE CIRCUITS WILL BE RED IN COLOR AND THEIR LOCATION WILL BE NOTED AT EACH CONTROL UNIT. 5' 10' 15' 20' WIRE SCHEDULE NOTE DESCRIPTI❑N WIRES A SPEAKER CIRCUIT 1 PAIR #14'S TWISTED/SHIELDED B STROBE CIRCUIT 2 #14'S SYSTEM NOTES: <T> TO EXISTING TRANSPONDER <g> RELOCATE, REINSTALL AND RECONNECT EXISTING SMOKE DETECTORS ROOM 130E ROOM 130F L1-4 SP1 -4 15 cd SS C1/2W ROOM \ 130C \ \ ROOM SP1 -2 1_14 112W '2W SS , 30cd _ — _ _ SS 30cd "\A, B' ROOM 1301 L1-5\ 15%d 1/2W5`` I LI -6 30cd 9C / SP1 -6 1/2W �'L.ur1 LEVEL 1 ROOM 1300 ROOM 30 sed ss c1/2W AIB s�o SS cI I ROOM SS 130J 15.cl / \ IScd O / \ IT / p I \ SP1 -B ROOM / ROOM 1/2W ROOM 130K _ 130M 30cd SS 130L 1%2W SS 5cd m\ �ELECT� � } W Jx n Z Z F O O o Z o �z O ,n w a 3 3 � V Oln NaOZQ03 o w a'i'�u'oallo ECNa -w�W-N xdzwa aWZF Z wo�o��w�F o aooFF�zo z N W N N m p p m J m Z Z Z Q Z N 0 2 W z ~ Q W Q E F EC Z " Z W w w o 0 r .O?z - W O D o w Z Z Z O W ZD F J a d J t 7 Z J Z Q � U a3wo� F ..... V Z W W W U1W O w woo 2 x W W zz <w -F ..Q C7 Z J L0 LL (V p 10 Z) z H 'o Lu M Lu N _ H J Of �r K') N J O LU <Iol c— z 3r Lu Lu of F— U Q J 0- N F— m Q _ b X Lu Q O Lu 0� W C/) Of I > Lo Lu CV >- J Lo m N FS NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: JPK DESIGNED BY: XXXX APPROVED BY: TDT DATE: 8/18/2017 SCALE: (ANSI B) 1/16" = I' PROJECT NO: XXXX REVISION NO: XXXX DRAWING NAME: BYU-I KIMBALL MAIN.DWG NELSON FIRE SYSTEMS LEVEL I SUITE 130 NOTIFICATION PAGE: FA -1-02 DEVICE LEGEND SYMBOL DESCRIPTI❑N Q SMOKE DETECTOR ss SPEAKER/STROBE— WALL ssc SPEAKER/STROBE— CEILING Eg FIRE ALARM CONTROL UNIT RA TRANSPONDER PANEL � } W Jx n Z Z F O O o Z o �z O ,n w a 3 3 � V Oln NaOZQ03 o w a'i'�u'oallo ECNa -w�W-N xdzwa aWZF Z wo�o��w�F o aooFF�zo z N W N N m p p m J m Z Z Z Q Z N 0 2 W z ~ Q W Q E F EC Z " Z W w w o 0 r .O?z - W O D o w Z Z Z O W ZD F J a d J t 7 Z J Z Q � U a3wo� F ..... V Z W W W U1W O w woo 2 x W W zz <w -F ..Q C7 Z J L0 LL (V p 10 Z) z H 'o Lu M Lu N _ H J Of �r K') N J O LU <Iol c— z 3r Lu Lu of F— U Q J 0- N F— m Q _ b X Lu Q O Lu 0� W C/) Of I > Lo Lu CV >- J Lo m N FS NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: JPK DESIGNED BY: XXXX APPROVED BY: TDT DATE: 8/18/2017 SCALE: (ANSI B) 1/16" = I' PROJECT NO: XXXX REVISION NO: XXXX DRAWING NAME: BYU-I KIMBALL MAIN.DWG NELSON FIRE SYSTEMS LEVEL I SUITE 130 NOTIFICATION PAGE: FA -1-02