HomeMy WebLinkAboutTRUSS SPECS - 17-00548 - 2176 Summerfield Ln - New SFR0
N99
N99 ype
TCHNER SF4B11 RD 'D'
1]-OBH29T
A97
Common
5
1
SPACING- 2-0-0
CSI.
DEFL,
in
floc)
I/deft
Jab Reference (ppt'pnap
BMC WEST (IDAHO FALLS). IDAHO FALLS, ID 83402
01
4x5 -
6.00 i t2
Scale: 1/4'=1'
3x6 = 5x8 = 5x8 = 3x6 =
9-0-0
12
Plate Offsets (X,Y)--
IH:0-4-0.0-3-01. 11:04-0.0-3-01
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL,
in
floc)
I/deft
Lid
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.60
Vert(LL)
-0.29
H -I
>999
360
MT20
220/195
TCDL 7.0
Lumber DOL 1.15
8C 0.50
Vert(TL)
-0.43
H -I
>775
240
BCLL 0.0
Rep Stress Incr YES
WB 0.21
Horz(TL)
0.08
F
n/a
n/a
SCOL 7.0
Code IRC2012/7PI2007
(Matrix)
Wind(LL)
0.09
B -I
>999
240
Weigh1:117lb
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E TOP CHORD
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E BOT CHORD
WEBS 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E `Except'
W2,W4: 2x4 DF Stud/Std
REACTIONS. (Ib/size) 8=1458/0-5-8 (min. 0-1-9), F=1458/0-5-8 (min.0-1-9)
Max HorzB=133(LC 12)
Max UpliftB=-289(LC 8), F=-289(LC 9)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD B -C=-2409/441, C -D=-2078/431, D -E=-2078/431, E -F=-2409/442
BOT CHORD B-1=129/2036, 1-J=-158/1331, J -K=-158/1331, H -K=-158/1331, F -H=-297/2036
WEBS D -H=-197/746, E -H=-573/288, D-1=-197!746, C -I=-573/288
Sheathed or 3-8-6 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; 11=2511; Cat. ll; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This /mss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members, with BCDL = 7.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (jl=1b) 8=289,
F=289.
6) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) "Semi-dgid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
0
N59
was ype
KARTCHNERSF4811 ROGWORD-D'
17.0811291
A02
Common
9
1
CSI.
DEFL.
In
(loc)
I/deft
L/d
Job Reference (optional)
�M• V.L •oma^•�• a 0
7"'"ulo
- mi i ex inausmes. mc. me Au
g 2915:13292017 PyID:UdjBElbvXzN?dbglDnTVzMMp-evFgkrUXNOrPpHSfNSzQOFXYH'wGD9mmel
770-0 0 21-0.0 28-0-0 x
0 7 7.0-1-00--00 4-0
1-
45 =
sm
Scale = 1:46.9
4x5 = 5x8 = 5x8 = 4x5 =
11
Plate Offsets (X Y)-
[G:04-0,0-3-01. IH:0-4-0 0-3-01
LOADING (pan
SPACING- 2-0-0
CSI.
DEFL.
In
(loc)
I/deft
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.62
Vert(LL)
-0.29
G -H
>999
360
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.54
Vert(TL)
-0.42
G -H
>785
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.22
Horz(TL)
0.08
F
n/a
n/a
BCDL 7.0
Code IRC2012/TPI2007
(Matrix)
Wind(LL)
0.10
F -G
>999
240
Weight:115lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 OF 180OF 1.6E or 2x4 DF No.l&Btr or 2x4 DF -N 180OF 1.6E TOP CHORD
BOT CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.l&Btf or 2x4 DF -N 1800F 1.6E BOT CHORD
WEBS 2x4 OF 180OF 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 180OF 1.6E *Except*
W2,W4: 2x4 OF Stud/Std
REACTIONS. (Ib/size) F=1355/Mechanical, 8=1469/0-5.8 (min. 0-1-9)
Max Horz8=141(LC 12)
Max UpliflF=-256(LC 9), B=-290(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=-2431/444, C -D=-2101/434, D -E=.2132/444, E -F=-2473/458
BOT CHORD B -H=-040/2056, H -I=-169/1353, IJ= -169/1353, G -J=-169/1353, F.G=-332/2107
WEBS D -G=-208/786, E -G=-606298, D -H=-1971745, C.H=.573/288
Sheathed or 3-64 oc purlins.
Rigid ceiling directly applied or 9-11.9 oc bracing
MiTek recommends that Stabilizers and required cross bracing
be Installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live bads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members, with BCDL = 7.Opsf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=1b) F=256,
B=290.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
8)'Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
russ
I rus3 I ype
ty
y
KARTCHNER SF4B11 ROCKFORD-D'
IM81129T
A03
Ca=w
1
i
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
Job Reference ioptionall
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ami
4x5 =
Scale =1:46.7
5xa = 5x8 = """
Plate Offsets(X.Y)--
[8:0-2-90-1-8]fF:0-2.90-1-81
IG:04-00-3-01
IH:0-4-00-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loo)
I/deb
L/d
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.61
Ver(LL)
.0.29
G -H
>999
360
MT20
220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.52
Ven(TL)
-0.42
G -H
>783
240
BCLL 0.0 '
Rep Stress ]nor YES
WB 0.21
Horz(TL)
0.08
F
n/a
n/a
BCDL 7.0
Code IRC2012rTP12007
(Matrix)
Wind(LL)
0.10
F -G
>999
240
Weight: 1151b
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 OF 1800F 1.6E or 2x4 DF No.i&Btr or 2x4 DF -N 180OF 1.6E TOP CHORD
BOT CHORD 2x4 OF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E BOT CHORD
WEBS 2x4 OF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E *Except*
W2,W4: 2x4 OF Stud/Std
REACTIONS. (Ib/size) F=1347/0-5-8 (min. 0-1-8), B=1461/0-5-8 (min. 0-1-9)
Max Horz B=141(LC 8)
Max UpliftF=-254(LC 9), B=-289(LC 8)
FORCES. (lb) - Max. Comp./Max, Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=-2414/442, C -D=-2083/432, D.E=-2093/436, E -F=-2426/448
BOT CHORD B -H=-038/2041, H -I=-167/1337, W=-167/1337, G -J=-167/1337, F -G=-321/2055
WEBS D -G=-201/758, E -G=-581/291, D -H=-1971746, C -H=-573/288
Sheathed or 3-7-9 oc purlins.
Rigid ceiling directly applied or 9-11-14 oc bracing
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, In accordance with Stabilizer
Installation guide.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members, with BCDL = 7.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except (jt=lb) F=254,
B=289.
6) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSIrrPI 1.
7) "Semi-dgid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job Me
nlss ype
ty
y
KARTCHNERSF4B11R0CKF0R0"W
17-0911297 B01
California
1
1
LOADING (psf)
SPACING- 2-0-0
J b R ference ( p0 0
M
�1
Scale =1:49.6
5x8 =
4x5 =
axe o - .1
3x8 11
1.5x4 II 3x4 = 5x8 = 1.5x4 11
6511 12-11-6 I 15-0-10 21.6-5 ROM
6511 85-11 9dd R_Fd1 {-iH
Iy
Plate Offsets (X.Y)-
[B:0-2-9,0.11-8% [D:04-0.0-1-15].
[G:0-2-9,0-1-81,
[J:0 -3-4 ,0-M]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loo)
I/dell
L/d
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC
0.48
Vert(LL)
-0.12
K
>999
360
MT20
220/195
TCDL 7.0
Lumber DOL 1.15
BC
0.42
Ved(TL)
-0.22
K -L
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB
0.66
Horz(TL)
0.09
G
n/a
n/a
BCDL 7.0
Code IRC2012rTP12007
(Matrix)
Wind(LL)
0.06
K
>999
240
Weight:136lb
FT=20%
LUMBER -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1 &Btr or 2x4 DF -N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1 &Btr or 2x4 OF -N 1800F 1.6E
WEBS 2x4 DF Stud/Std
REACTIONS. (Ib/size) B=1458/0-5-8 (min. 0-1-9), G=1458/0-5-8 (min. 0-1-9)
Max Horz B=122(LC 12)
Max UpliftB=.282(LC 8), G=-282(LC 9)
BRACING.
TOP CHORD Sheathed or 3-10-5 oc purlins, except
2-0-0 oc purlins (54-11 max.): D -E.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
rMiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=.2465/420, C -D=-1751/307, D -E=-1443/324, E -F=-1758/309, F -G=-2464/421
BOT CHORD B -L=-405/2088, K -L=-405/2088, J -K=-162/1442, I -J=-283/2087, G -I=.283/2087
WEBS C -K=.734/271, D -K=-86/388, D -J=.261/266, E -J=-87/393, F -J=-729/271
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) B=282,
G=282.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSUTPI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
0
nlss
may ype
KARTCHNER SF4B11 ROCKFORD 'D'
17-081129T
B02
Cal ficmia
1
i
CSI.
DEFL.
in
(loc)
I/den
Job Reference (optional)
BMC NEST (IDAHO FALLS), IDAHO FALLS,
vI
0
5x8 =
0
4x5 =
Scale =1:48.5
45 = 11 " ' ^ 4x5 =
1.5x4 II
3x4 = 5x8 =
1.5x4 II
65-11 12-11-6 15.0.10 215-5 28-0-0
BS -11 65-11 2-1-0 65-11 65-11
Plate Offsets(XY)-.
(D:0-4-00-1-151 fG:0-1-0Edgel
[1:0.3-40-3-01
LOADING (psf)
SPACING. 2-0-0
CSI.
DEFL.
in
(loc)
I/den
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.51
Vert(LL)
-0.13
J
>999
360
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.49
Vert(TL)
-0.23
J -K
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.70
Hom(TL)
0.09
G
n/a
n/a
BCDL 7.0
Code IRC2012frP12007
(Matrix)
Wind(LL)
0.07
G -H
>999
240
Weight: 1341b FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E TOP CHORD
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E
WEBS 2x4 OF Stud/Std BOT CHORD
REACTIONS. (Ib/size) G=1355/Mechanical, 8=1469/0-5-8 (min. 0.1-9)
Max Horz B=131(LC 12)
Max UpliftG=-249(LC 9), 8=-283(LC 8)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=-2487/423, C -D=-1775/310, D -E=-1467/329, E.F=-1786/315, F -G=.2538/439
BOT CHORD B -K=-416/2108, J -K=-416/2108, IJ= -173/1463, H -I=.319/2166, G.H=-319/2166
WEBS CJ= -734/271, D -J=-86/388, D -I=-258/271, E -I=-89/404, F -I=-785/286
Sheathed or 3-8-8 oc pudins, except
2.0.0 oc purlins (54-3 max.): D -E.
Rigid ceiling directly applied or 10-0-0 ac, bracing
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
In
fide.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91mph; TCDL=4.2psh BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live bads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except Qt=11h) G=249,
B=283,
8) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
9) "Semi.dgid pltchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss,
10) Graphical purlin representation does not depict the size or the orientation of the pudin along the top and/or bottom chord.
LOAD CASES) Standard
0
was
was ype
0-3-01
KARTCHNERSF4B11 ROCKFORD-D'
17-081129T
C01
Common
5.
1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
Job Reference ( ptiona0
0,00 ,v,. ;U;... .,e, ,.,
2
4x5 11
Scale =1:41.4
ox. — Mb = -^-
Plate Offsets (X,Y)--
IB:0-24,0-1-81, IF:0-2-4,0-1-81
IH:0-3-0
0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(lac)
I/deft
Ud
PLATES
GRIP
TCLL 35.0
Plate Grp DOL 1.15
TC 0.35
Vert(LL)
-0.12
H-1
>999
360
MT20
220/195
TCDL 7.0
Lumber DOL 1.15
SC 0.30
Ven(TL)
-0.18
H-1
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.13
HOrz(TL)
0.04
F
n/a
n/a
BCDL 7.0
Code IRC2012/TPI2007
(Matrix)
Wind(LL)
0.04
B -I
>999
240
Weight: 97 lb
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E TOP CHORD
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E BOT CHORD
WEBS 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E *Except`
W2,W4: 2x4 OF Stud/Std
REACTIONS. (Ib/size) B=1165/0-5-8 (min.0-148), F=1165/0-5-8 (min. 0-1-8)
Max Horz B=-184(LC 6)
Max UpliftB=-229(LC 8), F=-229(LC 9)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=-1676/298, C -D=-1448/322, D -E=-1448/322, E -F=-1676/298
BOT CHORD B -I=-287/1341, 1-J=-88/883, J -K=-88/883, H -K=-88/883, F -H=-163/1341
WEBS D -H=-163/571, E -H=-417/233, D -I=-163/571, C-1=417/233
Sheathed or 4-11-0 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, In accordance with Stabilizer
Installation guide.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91mph; TCDL=4.2psf BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 Wide will fit
between the bottom chord and any other members, with BCDL = 7.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except (jt=1b) 13=229,
F=229.
6) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) "Semi-dgid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
LOAD CASE($) Standard
Job
was
NSS ype
0-1-81
BOT CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 180OF 1.6E BOT CHORD
K RTCHNER SF4811 ROCKFORD-D'
17.08i129T
002
Common Btroolural Gable
1
1
SPACING- 2-0-0
REACTIONS. All bearings 11.1-8 except (jt=length) F=0-5-8, 1=0-3-8, 1=0-3-8.
CSI.
DEFL.
in
(loc)
Job R f ce ( pfionall
2x4 =
5x8 =
M L K J AC I "'
7<-0 1 10-10-0 14-8-0 1 22-0-0 4
721M v.en
N
0
Scale = 1:47.3
Plate Offsets (X.Y)--
IB:0-2-40-1-81 [D:0-2-0.0-0-0),
IF:0-2-4
0-1-81
BOT CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 180OF 1.6E BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
LOADING (psi
SPACING- 2-0-0
REACTIONS. All bearings 11.1-8 except (jt=length) F=0-5-8, 1=0-3-8, 1=0-3-8.
CSI.
DEFL.
in
(loc)
I/deb
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.36
Vert(LL)
-0.06
F -H
>999
360
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.22
Vert(TL)
-0.13
F -H
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.80
Horz(TL)
0.01
F
n/a
n/a
BCDL 7.0
Code IRC2012/TPI2007
(Matdx)
Wind(LL)
0.03
F -H
>999
240
Weight:1391b FT=20°/
LUMBER- BRACING -
TOP CHORD 2x4 DF i800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E TOP CHORD
Sheathed or 6-0-0 oc pudins.
BOT CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 180OF 1.6E BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installationuide.
REACTIONS. All bearings 11.1-8 except (jt=length) F=0-5-8, 1=0-3-8, 1=0-3-8.
(lb) - Max Harz B=-184(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) B, M except F=-182(LC 9), K=-290(LC 8)
Max Grav All reactions 250 Ib or less at joint(s) J, L, M, I, 1 except B=343(LC 19), F=760(LC
1), K=1119(LC 1)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD C -D=-21/316, D -E=-674/233, E -F=-9021209
BOT CHORD F -H=-87/685
WEBS D -H=-174/530, E -H=-432/235, D -K=-805/141, C -K=-451/245
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psh BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (none] to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/rPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.Opsf.
8) Provide mechanical connection (by others) of truss to beading plate capable of withstanding 100 Ib uplift at joint(s) B, M except Qt=1b)
F=182, K=290.
9) This truss is designed In accordancewith the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/rPI 1.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
Nes
was ype
y
K RTCHNERSF4Bi1 ROCI(FORD'D°
17-081129T
CO3
Common Giber
1
2
Job Reference (optional)
(IDAHO FALLS), IDAHO FALLS, ID 83402 0.000 s Jul 15 2016 MiTek Industries, Inn Tue Aug9 2915:13:372017 Pa99a 1
ID:Uv djBEjbvXzN?dbgtDnTVzAOMp-PSkhPaaYVrsHmWiBr861jxGtSGcuSedvug3p?1p
5-6-0 t1-0-0 16.8-0 22-0-0
5-6-0 5-6-0 5.6-0 5E-0 xLy
5x8 11
4X12Q
4x1211 12x16MT18H= 4x1211
5-6-0 11-0-0 16-6-0 22-0-0
5-8-0 1 511 1 Mo 1 543-0 1
Scale =1:40.8
i
Plate Offsets (X.Y)—
tA:0-3-6,0-1-121. [E:0-3-6.0-1 12]
LOADING (pan
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.74
Vert(LL)
-0.22
F -G
>999
360
MT20
220/195
TCDL 7,0
Lumber DOL 1.15
BC 0.75
Vert(TL)
.0.35
G -H
>741
240
MT18H
220/195
BCLL 0.0 '
Rep Stress Incr NO
WB 0.80
Hom(TL)
0.09
E
n/a
n/a
BCDL 7.0
Code IRC2012rrP12007
(Matrix)
Wind(LL)
0.11
G -H
>999
240
Weight: 256 to
FT = 20%
LUMBER -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.18Btr or 2x4 DF -N 1800F 1.6E
BOT CHORD 2x8 OF 1950E 1.7E or 2x8 OF SS
WEBS 2x4 OF Stud/Std *Except'
W7: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Bir or 2x4 DF -N 1800F 1.6E
REACTIONS. (Ib/size) A=7761/0-5.8 (min. 04-2), E=7761/0-5-8 (min. 0-0-2)
Max Horz A=-165(LC 25)
Max UpliftA=-1511(LC 8), E=-l517(LC 9)
BRACING -
TOP CHORD Sheathed or 3-2-12 cc purlins.
BOT CHORD Rigid ceiling directly applied or 10.0-0 cc bracing.
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD A -B=-12755/2475, B -C=-8667/1724, C.D=.8667/1725, D -E=-12755/2480
BOT CHORD A -I=-2178/10933, IJ= -2178/10933, H.J=-2178/10933, H -K=-2178/10933, K -L=-2178/10933,
L -M=-2178/10933, G -M=-2178/10933, G -N=-2070/10933, N -O=-2070/10933, O -P=-2070/10933,
F -P=-2070/10933, F -Q=-2070/10933, Q -R=-2070110933, E -R=-2070/10933
WEBS C -G=-1591/8158, D -G=-4097/930, D -F=-665/3637, B -G=4097/925, B -H=-660/3637
NOTES -
1) 2 -ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 -1 row at 0-7-0 cc.
Bottom chords connected as follows: 2x8 -2 rows staggered at 0-6-0 cc.
Webs connected as follows: 2x4 - 1 row at 0-9.0 cc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25tt; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads.
7)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except Qt=lb) A=1511,
E=1517.
9) This truss Is designed In accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSIfrPI 1.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Use Simpson Strong -Tie HUS26 (14.10d Girder, 4-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 cc max. starting at 4-0.0
from the left end to 18-0-0 to connect truss(es) A02 (i ply 2x4 DF -N or DF) to back face of bottom chord.
12) Fill all nail holes where hanger is in contact with lumber.
13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated Ioad(s)1341 Ib down and 263 Ib up at
2-0-0, and 1341 Ib down and 270 lb up at 20-0.0 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
&OAiDr@4'l3 POOt>&ldard
o
rues
was ype
y
KARTCHNERSF4B11 ROCKFORD'O'
1]-081129T
003
Common Girder
1
n
2
Job Reference loptional)
a.uuu sam i o em a m.. exmausmes, inc. i ue Auvv2a 15:13:3] 201] Pa?
ID:Uv djBEjbvXzN7dbg1 tSGcu5edwq3p?lyxLy
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (pil)
Vert: A -C=-84, C -E=-84, A -E=-14
Concentrated Loads (lb)
Vert: 1=-1341(B)J=-1341(B)K=-1341(B)L=-1341(B)M=-1341(8) N= -1341(B)0= -1341(B) P= -1341(B)0=-1341(8) R= -1341(B)
Job
rus3
I russ I ype
y
BOT CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 180OF 1.6E
KARTCHNER SF4911 ROCKFORD'D-
17-081129T
001
Califomis Supported Gable
1
1
LOADING (psf)
SPACING. 2-0-0
he Installed Installed during truss erection, In accordance with Stabilizer
CSI.
DEFL.
in
Jab Reference (opdona0
3x4 =
314 =
Scale = 1:49.8
a%4 AF AE AD AC AS AA Z V X W V U T 3x4 =
5x6 =
Plate Offsets KY)-
I1-1:0-2-O.Edgel IL:0-2-0.Edoe1 fY:0-3-00-3-01
TOP CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 1800F 1.6E
TOP CHORD Sheathed or 6.0-0 oc purlins, except
BOT CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 180OF 1.6E
2-0-0 oc purlins (6-0-0 max.): H.L.
OTHERS 2x4 OF Stud/Std
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
LOADING (psf)
SPACING. 2-0-0
he Installed Installed during truss erection, In accordance with Stabilizer
CSI.
DEFL.
in
floc)
I/deb
L/d
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.07
Vert(LL)
-0.00
S
n/r
120
MT20
220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.02
Vert(TL)
-0.00
S
n/r
120
BCLL 0.0 '
Rep Stress Incr YES
WB 0.10
Hoa(TL)
0.00
R
n/a
n/a
BCDL 7.0
Code IRC2012/rP12007
(Matrix)
Weight: 1421b
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 1800F 1.6E
TOP CHORD Sheathed or 6.0-0 oc purlins, except
BOT CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 180OF 1.6E
2-0-0 oc purlins (6-0-0 max.): H.L.
OTHERS 2x4 OF Stud/Std
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
he Installed Installed during truss erection, In accordance with Stabilizer
I
REACTIONS. All bearings 28-0-0.
(lb) - Max Horz B=108(LC 12)
Max Uplift All uplift 100 lb or less atjoint(s) B, Z, AA, AS, AC, AD, AE, AF, Y. X, W, V. U, T, R
Max Grav All reactions 250 It, or less at joint(s) B, Z, AA, AS, AC, AD, AE, AF, Y, X, W, V, U, T, R
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7.10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) All plates are 1.5x4 MT20 unless otherwise Indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 2-0-0 no.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100Ib uplift at joint(s) B, Z, AA, AS, AC, AD
, AE, AF, Y. X, W, V, U. T. R.
11) This truss is designed in accordance with the 2012 International Residential Code sections R502A 1.1 and R802.10.2 and referenced
standard ANSIrrPI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
13) Graphical purlin representation does not depict the size or the orientation of the pur in along the top and/or bottom chord.
LOAD CASE(S) Standard
Job
mss
Truss I ype
ply
KARTCHNERSF41311 ROCKFORD"D"
17-0811297
D02
California Supported Gable
1
1
SPACING- 2 -OA
CSI.
DEFL.
in
floc)
Job Reference (optional)
BMC WEST (IDAHO FALLS). IDAHO FALLS, ID 83402
"7
9'
3x4 = AE AD AC AS AA
3x4 =
3x4 =
Scale =1:49.8
X W
5x8 =
3x4 --
Plate Offsets (X Y)--
Plate
11-1:0-2-0,Edge], I1-:0-2-0 Edgel
[X:0-3-0.0-3-01
LOADING (pat)
SPACING- 2 -OA
CSI.
DEFL.
in
floc)
I/deft
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.07
Vert(LL)
-0.00
A
n/r
120
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.02
Vert(TL)
-0.00
A
n/r
120
BCLL 0.0 '
Rep Stress Incr YES
WB 0.10
Horz(TL)
0.00
R
n/a
n/a
BCDL 7.0
Code IRC2012/TPI2007
(Matrix)
Weight: 141 Ib FT = 20
LUMBER -
TOP CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.1&Str or 2x4 DF -N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 OF No,1&Btr or 2x4 DF -N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOPCHORD
BOT CHORD
Sheathed or 6-0-0 oc pur ins, except
2-0A oc purlins (6-0A max.): H -L.
Rigid ceiling directly applied or 10-0-0 oc bracing
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. All bearings 28-0-0.
(Ib) - Max Harz 8=117(LC 12)
Max Uplift All uplift 1001b or less at joint(s) B, Y. Z. AA, AB, AC, AD, AE, X, W, V, U, T. S
Max Grav All reactions 250 Ib or less at joint(s) R, B, Y. Z, AA, AB, AC, AD, AE, X, W, V, U, T, S
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/rPI 1.
4) Provide adequate drainage to prevent water ponding.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 2-0-0 Do.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-M tall by 2-0-0 wide will ft
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joints) B, Y, Z, AA, AB, AC,
AD, AE, X, W, V, U. T, S.
11) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
12) "Semi-rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
0
NS5
NSS ype
KARTCHNER SF4aH ROCKFORD-D'
1]-0aH 29T
E07
Common
4
1
SPACING.
2-0-0
CSI.
DEFL.
In
floc)
Job Reference (opdonap
omu;Z37 j;DG. 43,;..,,,.. FALL3Ju
45 =
Scale =1:41.7
3x4 = 5xe = 3%15—
Plate Offsets (X.Y)--
1H:0-3-0.0-3-01
LOADING (pan
SPACING.
2-0-0
CSI.
DEFL.
In
floc)
I/deft
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL
1.15
TC 0.43
Vert(LL)
-0.12
1
>999
360
MT20 220/195
TCDL 7.0
Lumber DOL
1.15
BC 0.43
Vert(TL)
-0.24
B-1
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.30
Horz(TL)
0.07
F
n/a
n/a
BCDL 7.0
Code IRC2012/TPI2007
(Matrix)
Wind(LL)
0.06
B-1
>999
240
Weight: 96 He FT = 20%
LUMBER -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.t&Bir or 2x4 DF -N 180OF 1.6E
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF NoA&Btr or 2x4 DF -N 180OF 1.6E
WEBS 2x4 DF Stud/Std
REACTIONS. (Ib/size) B=1263/0-3-8 (min. 0-1-8), F=1263/0-3-8 (min. 0-1-8)
Max Horz 8=96(LC 12)
Max UpliftB=-255(LC 8), F=-255(LC 9)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=.2379/446, C -D=-2038/393, D -E=-2038/394, E -F=-2379/446
BOT CHORD B-1=-435/2107, H.I=-180/1377, F -H=-339/2107
WEBS D -H=-156/676, E -H=-528/244, D -I=-156/676, C -I=-528/244
BRACING -
TOP CHORD Sheathed or 3-11-14 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
[Tek recommends that Stabilizers and required cross bracing
he installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psh h=25ft; Cat. 11; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 pat bottom chord live load noncencurrent with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=1b) B=255,
F=255.
6) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/rPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
russ
was Type
Uty
Ply
K RTCHNER8F4811 ROCKFORD-17
17-0811207
G01
Califomis
7
1
CSI.
DEFL.
in
(loo)
I/deft
L/d
Job Reference (optional)
6X8 =
4x5 =
Scale =1:43.0
3x6 = - .. 3x6 =
3x4 =
5x8 =
1.5x4 II
5-0-7 1 10-8-14 1 73.32 1 18-7-9 24-11-0 {
54-7 5-0-] 9R.5 Sd-7 Fd-]
I�
Plate Offsets (X,Y)--
ID:0-4-2,Edge1. IJ:0-3-0,0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loo)
I/deft
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.32
Vert(LL)
-0.12
K
>999
360
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.38
Vert(TL)
-0.21
K -L
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.40
Horz(TL)
0.08
G
We
We
BCDL 7.0
Code IRC2012fTP12007
(Matrix)
Wind(LL)
0.06
K
>999
240
Weight:109lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E TOP CHORD
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E
WEBS 2x4 DF Stud/Std BOT CHORD
REACTIONS. (Ib/size) B=1263/0-3-8 (min. 0-1-8), G=1263/0-3-8 (min. 0-1-8)
Max Horz B=86(LC 12)
Max UpliftB=-246(LC 8), G=-246(LC 9)
FORCES. (lb) -Max, Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD B -C=-2433/415, C -D=-1766/289, D -E=-1540/301, E -F=-1775/291, F -G=-2432/416
BOT CHORD B -L=-401/2159, K -L=-401/2159, J -K=-188/1539, 1-J=-316/2158, G -I=-316/2158
WEBS C -K=-682/230, D -K=-59/327, EJ= -53/325, F -J=-675/230
Sheathed or4-0-10 oc purlins, except
24-0 oc purlins (5-3-15 max,): D -E.
Rigid ceiling directly applied or 10-0-0 oc bracing
MiTek recommends that Stabilizers and required cross bracing
be Installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fl
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at Joint(s) except Qt=lb) B=246,
G=246.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/fPI 1.
8) "Semi-rigid pitchbreaks with fixed heels- Member end fixity model was used in the analysis and design of this truss.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
0Truss
(F:0-2-O,Edgel, fJ:0-2-0,Edge1.
mss ype
TOP CHORD Sheathed or 6-0-0 oc pur ins, except
y
KAiTCHNER SF4611 ROCKFORD 'D'
17.0811297 J.
H01
California supported Gable
1
1
CSI.
DEFL,
in
floc)
Udell
Job Reference (optional)
6MG vvw, i,D,
i
3x4 =
3x4 =
Scale =1:43.0
3x4 = X W V U T S R O P 3x4 =
516 =
A
I$
Plate Offsets (X,Y)--
(F:0-2-O,Edgel, fJ:0-2-0,Edge1.
IR:0-3-0.0-3-01
TOP CHORD Sheathed or 6-0-0 oc pur ins, except
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF NO.I&Btr or 2x4 DF -N 180OF 1.6E
2-M oc purlins (6-0-0 max.): FJ.
OTHERS 2x4 OF Stud/Std
BOT CHORD Rigid ceiling directly applied or 10-0A oc bracing.
LOADING (psf)
SPACING- 2-0.0
CSI.
DEFL,
in
floc)
Udell
Lid
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
Max Uplift All uplift 100 lb or less at joint(s) B, T. U, V, W, S, R, Q, N
TC 0.13
Vert(LL)
0.00
O
n/r
120
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.06
Vert(TL)
0.01
O
n/r
120
BCLL 0.0 '
Rep Stress ]nor YES
WB 0.06
Hoa(TL)
0.00
N
We
n/a
BCDL 7.0
Code IRC2012/TPI2007
(Matrix)
Weight: 102 lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E
TOP CHORD Sheathed or 6-0-0 oc pur ins, except
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF NO.I&Btr or 2x4 DF -N 180OF 1.6E
2-M oc purlins (6-0-0 max.): FJ.
OTHERS 2x4 OF Stud/Std
BOT CHORD Rigid ceiling directly applied or 10-0A oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
tallationuide.
Ins
REACTIONS. All hearings 24-0-0.
(lb) - Max Horz B=-71 (LC 13)
Max Uplift All uplift 100 lb or less at joint(s) B, T. U, V, W, S, R, Q, N
except X=-117(LC 8), P=-117(LC 9)
Max Grav All reactions 250 Ib or less at joint(s) T, U, V, W, S, R. Q except B=271(LC 1), X=375(LC 19), P=375(LC
20), N=271(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
WEBS C -X=-299/136, M -P=-299/135
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psh BCDL=4.2psf, h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/rPI 1.
4) Provide adequate drainage to prevent water ponding.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 2-0-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load noncencurrent with any other live loads.
9)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) B, T, U, V, W, S, R.
Q, N except Qt=lb) X=117, P=117.
11) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI?PI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Job
ruse
fuss ypejPlYK
DEFL.
in (loo)
TCHNERSF4B11 ROCKFORD-D'
17.0811297
K01
Common Supported Gable
1
1
Vert(LL)
-0.00 1
n/r
120
MT20 220/195
TCDL 7.0
Job Reference (optional)
�••�^-� ••�•^---r• ^•�•^-- -��••�w Sam mzmo MneKinaumnes,ma me,wg2915:13472017 Paget
-1-0-0 5A-0 ID:UwzdjBEjbvXzN?dbgl DnTVzAdMp-6NKTV?Ip8Y6sz2T6REle72gI01CVRLI NBOULMjytxLo
0 12-0-0
1-0-0 5-8-0 5.8-0 1-0-0
45 =
Scale =1:23.0
��• — 3x4 =
a
LOADING (psf)
SPACING -2-1-0
CSI.
DEFL.
in (loo)
I/defi
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.07
Vert(LL)
-0.00 1
n/r
120
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.03
Vert(TL)
-0.00 1
n/r
120
BCLL 0.0 '
Rep Stress Incr YES
W8 0.04
Horz(TL)
0.00 H
nla
n/a
BCDL 7.0
Code IRC2012/TPI2007
(Matrix)
Weight: 481b FT=20%
LUMBER -
TOP CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.18Btr or 2x4 DF -N 180OF 1.6E
BOT CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.18Btr or 2x4 DF -N 180OF 1.6E
OTHERS 2x4 OF Stud/Std
REACTIONS. All beadngs l l-4-0.
(lb) - Max Horz B=.103(LC 6)
Max Uplift All uplift 1001b or less atjoint(s) B, H, M, N, K. J
Max Grav All reactions 250 lb or less at joint(s) B, H, L. M, N, K, J
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
BRACING -
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation oulde.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7.10; Vult=115mph (3 -second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate gdp DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, H, M, N, K, J.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11,1 and R802.10.2 and referenced
standard ANSI/TPl 1.
11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
o
russ
mss ype
5-8-tr
y
KARTCHNERSF4B11 ROCKFORD -D-
7.081129T
110708
L01
Monopitch
7
1
DEFL,
in
(loc)
I/deb
L/d
PLATES GRIP
Job Reference (optional)
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
8.000 s Jul 152016 MiTek Industries, Inc. Tue Augg 2915:13:48 2017 Pagge 1
ID:LlwzdjBEjbvXzN?dbgl DnTVZAdMpaZusjLJRvsEjbC21_xptfFDpuhUmAouXO2Euu9yixLn
1.5x411 Scale =1:14.7
C
2x4 =
LUMBER -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E
BOT CHORD 2x4 DF 1800E 1.6E or 2x4 DF No.t&Btr or 2x4 DF -N 1800F 1.6E
WEBS 2x4 OF Stud/Std
REACTIONS. (Ib/size) 8=390/0-3-8 (min. 0-1-8), 0=269/0-1-8 (min. 0-1-8)
Max Horz 8=98(LC 4)
Max UpliftB=-115(LC 4), D=-79(LC 8)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
BRACING -
TOP CHORD Sheathed or 5-10-8 oc purlins, except and verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, In accordance with Stabilizer
installation guide.
NOTES -
1) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psh BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Bearing at joint(s) 0 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verity capacity of
bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) D.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) D except Ot=lb)
B=115.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/rPI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
u -z -u
5-8-tr
LOADING (ps/)
SPACING- 2-0-0
CSI.
DEFL,
in
(loc)
I/deb
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.53
Vert(LL)
-0.06
B -D
>999
360
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.22
Vert(TL)
.0.11
B -D
>600
240
BCLL 0.0 '
Rep Stress Incr VES
WB 0.00
Horz(TL)
0.00
n/a
n/a
BCDL 7.0
Code IRC20121TP12007
(Matrix)
Wind(LL)
0.00
B
""
240
Weight: 20 lb FT=20%
LUMBER -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E
BOT CHORD 2x4 DF 1800E 1.6E or 2x4 DF No.t&Btr or 2x4 DF -N 1800F 1.6E
WEBS 2x4 OF Stud/Std
REACTIONS. (Ib/size) 8=390/0-3-8 (min. 0-1-8), 0=269/0-1-8 (min. 0-1-8)
Max Horz 8=98(LC 4)
Max UpliftB=-115(LC 4), D=-79(LC 8)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
BRACING -
TOP CHORD Sheathed or 5-10-8 oc purlins, except and verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, In accordance with Stabilizer
installation guide.
NOTES -
1) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psh BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Bearing at joint(s) 0 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verity capacity of
bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) D.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) D except Ot=lb)
B=115.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/rPI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
job
was
mss ype
DEFL.
y
KARTCHNERSF4611 ROCKFORD-D'
77-0611297
LG01
GABLE
1
7
Vert(LL)
We -
n/a
999
MT20 220/195
TCDL 7.0
Job Reference (pgonal)
�•^�••�� •� •LL n ,. ..•..�.,,. ...,.,,.,. a.wu a A10xulu MneKinausmes,no. iue Aug2915:13492017 Pagel
ID:UwzdjBEjbvXzN7dbgl DnTVzAdMp-2mSEwhj3g9MaDMd WfK6CTm665t5vEOgeizSOcyixLm
4-1-13 83-10
4-1-13 4-1-13
4.5 =
H G F
2z4 // 1.5x4 11 1.5z4 I I 1.5x4 II 2z4 \\
6-3-10
Scale = 1:29.2
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
Well
Ud
PLATES GRIP
TCLL 35.0
Plate Gdp DOL 1.15
TC 0.06
Vert(LL)
We -
n/a
999
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.02
Vert(TL)
n/a -
n/a
999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.07
Horz(TL)
0.00 E
n/a
n/a
BCDL 7.0
Code IRC2012/TPI2007
(Matrix)
Weight: 37 lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btror 2x4 DF -N 1800F 1.6E TOP CHORD
BOT CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 1800F 1.6E BOT CHORD
OTHERS 2x4 OF Stud/Std
REACTIONS. All bearings 8-3-10.
(lb) - Max Hoa A=l 11(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) A, E except H=-171(LC 8), F=-171(LC 9)
Max Grew All reactions 250 Ib or less at joint(s) A, E, G, H, F
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
Sheathed or 6.0.0 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf, h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 vide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) A, E except (jt=1b)
H=171, F=171.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
russ
mss ype
y
y
KARTCHNER SF4811 ROCKFORD'D'
17-091129T
LG02
GABLE
2
1
Ve I(CL)
We -
n/a
999
MT20 2201195
TCDL 7.0
Job Reference o donal
uno...w r ...-� y .....,...,, ....,w...anu 1v 1 J: 1 JAI 2017 PaBB61
ID:UwzdjBEjbvXzN?dbglDnTVzAdMp_8a LNIKCndHSgntg4MaHurS vZaN8Pz6OSYVUYIxLk
35.8 6-11-1
3541 3-5-8
4x5 =
H G F
2x4 G 1.5x4 11 1.5x4 [I 1.5x4 II 20 \\
Scale = 1:29.7
LOADING (psf)
SPACING. 2-0-0
CSI.
DEFL
in (loo)
I/deg
Ltd
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.05
Ve I(CL)
We -
n/a
999
MT20 2201195
TCDL 7.0
Lumber DOL 1.15
BC 0.02
Vert(TL)
n/a -
n/a
999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.08
Hom(TL)
0.00 E
n/a
n/a
BCDL 7.0
Code IRC2012rfP12007
(Matrix)
Weight: 32 to FT=20°/
LUMBER- BRACING -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800E 1.6E TOP CHORD
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Bir or 2x4 DF -N 180OF 1.6E BOT CHORD
OTHERS 2x4 DF Stud/Std
REACTIONS. All bearings 6-11-1.
(Ib) - Max Horz A=-116(LC 4)
Max Uplift All uplift 100 to or less atjoint(s) A, E except H=-193(LC 8), F=-193(LC 9)
Max Grav All reactions 250 Ib or less at joint(s) A, E, G. H, F
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
Sheathed or 6-0-0 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf, BCDL=4.2psf; h=25fl; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) A, E except (jt=1b)
H=193, F=193.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI?PI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
russ
I Ns5 Jype
Qy
Fly
KARTCHNER SF4911 ROCKFORD 'D'
17.0911297
Min
Monopitch
5
1
SPACING-
2-0-0
CSI.
DEFL.
in
floc)
Job Reference (optional)
BMS, wco 1 -- r--,, -u O FALLS,
U' V8Jul'o"IU MI I eK nau5Ne3, inc. 1114 /88 29 15:13:522017 Papel,
1-0-0 ID:UwzdjBBBjbvXzN?dbgiDnNZAdMpSLBMZimyy4184gM3Dnupg5Ob5Jvn6cu6KgC61xyixLl
1-0-0 1-1018
2x4 =
Scale = 19.4
LUMBER -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.18Btr or 2x4 DF -N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.18Btr or 2x4 DF -N 1800F 1.6E
WEBS 2x4 OF Stud/Std
REACTIONS. (lb/size) B=211/0-5-8 (min. 0-1-8), 0=60/0-1-8 (min. 0-1-8)
Max Horz B=57(LC 8)
Max UpliftB=-52(LC 8), D=-21(LC 8)
FORCES. (lb) - Max. Comp.IMax. Ten. - All forces 250 (Ib) or less except when shown.
BRACING -
TOP CHORD Sheathed or 1-10-8 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cal. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads.
3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 Wide will fit
between the bottom chord and any other members.
4) Bearing at joint(s) D considers parallel to grain value using ANSIrrPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) D.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) B, D.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSIrl-PI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
7-105
1-105
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
floc)
I/deb
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL
1.15
TC 0.07
Vert(LL)
-0.00
B
>999
360
MT20 220/195
TCDL 7.0
Lumber DOL
1.15
BC 0.02
Vert(TL)
-0.00
B -D
>999
240
BCLL 0.0 '
Rep Stress [nor
YES
WB 0.00
Horz(TL)
0.00
We
n/a
BCDL 7.0
Code IRC20121TP12007
(Matrix)
Wind(LL)
0.00
B
""
240
Weight: 8 l FT=20%
LUMBER -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.18Btr or 2x4 DF -N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.18Btr or 2x4 DF -N 1800F 1.6E
WEBS 2x4 OF Stud/Std
REACTIONS. (lb/size) B=211/0-5-8 (min. 0-1-8), 0=60/0-1-8 (min. 0-1-8)
Max Horz B=57(LC 8)
Max UpliftB=-52(LC 8), D=-21(LC 8)
FORCES. (lb) - Max. Comp.IMax. Ten. - All forces 250 (Ib) or less except when shown.
BRACING -
TOP CHORD Sheathed or 1-10-8 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cal. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads.
3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 Wide will fit
between the bottom chord and any other members.
4) Bearing at joint(s) D considers parallel to grain value using ANSIrrPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) D.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) B, D.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSIrl-PI 1.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
rues
truss type
CSI.
y
KARTCHNERSF4811 ROCKFORD-D-
17-081129T
M02
MonopitM Supported Gable
1
1
1.15
TC 0.07
V.I( CIL)
0.00
A
n/r
Job Refer (optional)
ODAnv a.uuu s au r5 Zulu Mllex mcustnes, inn i ue Aug 101513:532017 Page 1
ID:UwzdjBEjbvXzN?dbg l DnTVzAdMp-xXhlm2majOt?hz%GnVP2MJwmx!F?r37GZKxfaNyixLl
-1-0-0 1-10-8
1-0-0 1-10-8
Scale = ISA
2x4 = 1.5x4 II
LOADING (psf)
SPACING-
2-0-0
CSI.
DFL
in
(loc)
Wall
L/d
TCLL 35.0
Plate Grip DOL
1.15
TC 0.07
V.I( CIL)
0.00
A
n/r
120
TCDL 7.0
Lumber DOL
1.15
BC 0.02
Vert(TL)
0.00
A
n/r
120
BCLL 0.0
Rep Stress Incr
VES
WB 0.00
Horz(TL)
0.00
n/a
n/a
BCDL 7.0
Cade IRC2012ITP12007
(Matrix)
LUMBER -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E
WEBS 2x4 OF Stud/Std
REACTIONS. (Ib/size) D=65/1-10-8 (min. 0-1-8), B=206/1-10-8 (min. 0-1-8)
Max Horz B=57(LC 8)
Max UpliftD=-22(LC 8), B=-51(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
PLATES GRIP
MT20 220/195
Weight: 8 l FT=20%
BRACING -
TOP CHORD Sheathed or 1-10-8 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psh h=25ft; Cat. 11; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads In the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSIf-PI 1.
3) Gable requires continuous bottom chord bearing.
4) Gable studs spaced at 2-0-0 Go.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) D, B.
8) Beveled plate or shim required to provide full bearing surface with truss chord at joints) B.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/rPI 1.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard