1
LOADING (psf)
SPACING- 2-0-0
Left: 2x4 OF Stud/Std
CSI.
DEFL.
Job Reference o Tonal
BMC MST (IDAHO FALLS), IDAHO FALLS, ID 13402 9.000 a Jul 152016 MiTek Intl 1 a as, Ina Tue Au ee 2901:38242017 Pagel
ID:RJgPDI WBJCgRAkoOBROTPgzkb03Jygny0j5Oui5v8RZ4LdaBCn94D8wzt2nJUMgNXy1015
x1-0.01 788 150.15 22-7-7 I 240.8
1-0-0 788 7-8-8 788 651
it
5x6 J
v nn I
Scale =149.9
3x8 11 1.5x4 II 5x6 = 48 = 2x4 11
78-8 1 150.15 1 22-7-7 1 29-0-8
78-8 7841 7-58 85-1
Plate Offsets (YY)-
IB:0-2-15,Edge1 W10-0-0,0-2-3].
[E:0-3-9,0-2-81, [1:0-3-0 ,0-3-01
TOP CHORD
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E
BOT CHORD
WEBS 2x4 DF 1800F 1.6E or2x4 DF No.1&Btror2x4 DF -N 1800F 1.6E'Excepl'WESS
W1,W3,EV2: 2x4 DF Stud/Std
LOADING (psf)
SPACING- 2-0-0
Left: 2x4 OF Stud/Std
CSI.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.90
Vert(LL)
-0.19
B -J
>999
360
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.64
Vert(TL)
-0.34
B -J
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.85
Horz(TL)
0.09
G
n/a
n/a
BCDL 7.0
Code IRC2012/TPI2007
(Matrix)
Wind(LL)
0.12
B -J
>999
240
Weight:1421b FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 DF 1800F 1.6E or2x4 DF No.1&Btror2x4 DF -N 1800F 1.6E
TOP CHORD
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E
BOT CHORD
WEBS 2x4 DF 1800F 1.6E or2x4 DF No.1&Btror2x4 DF -N 1800F 1.6E'Excepl'WESS
W1,W3,EV2: 2x4 DF Stud/Std
WEDGE
Left: 2x4 OF Stud/Std
REACTIONS. (Ib/size) B=1514/0-5-8 (min. 0-1-10),G=1402/0-6-8 (min. 0-1-8)
Max Horz B=238(LC 4)
Max UpliftB=-366(LC 4), G=-270(LC 8)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=-3208/670, C -D=-21941477. D -E=-1092/251, E -F=-1199/278, F -G=-1382/292
BOT CHORD B -J=-794/2907, 1-J=-796/2902, H -I=-512/1990
WEBS CJ=0/271, C -I=-978/303, D-1=42/443, 0-H=-1320/396, E -H=49/378, F -H=-219/1060
Sheathed or 2-8-10 oc purlins, except end verticals
Rigid ceiling directly applied or 7-4-11 oc bracing.
1 Row at midpt D -H
MiTek recommends that Stabilizers and required cross bracing
be Installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads,
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except Qt=1b) 3=366,
G=270.
8) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
0
N53
N53 ype
y
y
KeM1chner SF]08 DAVENPORT
1]-0810857
A03
GABLE
1
1
Installation guide.
CSI.
DEFL. in
floc)
Well
L/d
Job Reference (oplana0
Sim(, wca i (IDAHO FALLS). i VAnu FALLS, m 65402
45 Scale = 1:50.5
4.00 12 L
3x4 = AB AA Z y X W V U T S R D P
3x8 11 5,6 =
h
Plate Offsets (X Y)-
[B:0-0-0,0-1-31, IB:0-2-15 Edoe1
IG:0-3-0 0-3-01 [LT -2-15,0.2-41,
[W:0 -3-0 .0-3-P]
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 180OF 1.6E BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 OF Stud/Std
*Except*
MiTek recommends that Stabilizers and required cross bracing
OTHERS 2x4 OF Stud/Std
LOADING (psf)
SPACING- 2-0-0
Installation guide.
CSI.
DEFL. in
floc)
Well
L/d
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.19
Vert(LL) -0.00
A
n/r
120
MT20
220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.09
Vertf i-) 0.01
A
n/r
120
BCLL 0.0 '
Rep Stress Incr YES
WB 0.16
Horz(TL) 0.00
P
n/a
n/a
BCDL 7.0
Code IRC2012rFP12007
(Matrix)
Weight: 167 lb
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 OF 180OF 1.6E or 2x4 DF No.t&Btr or 2x4 DF -N 1800F 1.8E TOP CHORD
Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 180OF 1.6E BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 OF Stud/Std
*Except*
MiTek recommends that Stabilizers and required cross bracing
OTHERS 2x4 OF Stud/Std
be installed during truss erection, in accordance with Stabilizer
ST2: 2x4 OF 1800F 1.8E or 2x4 OF No.1&Btr or 2x4 DF -N 1800F 1.8E
Installation guide.
WEDGE
Left: 2x4 DF Stud/Std
REACTIONS. All bearings 29-0-8
(lb) - Max Horz B=238(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) P, B. S. T, U. V, W. X, Y. Z, AA, R, 0 except AB=-144(LC 8)
Max Grav All reactions 250 Ib or less at joint(s) P, S, T, U, V, W, X, Y, Z, AA, R, 0 except B=287(LC 1),
AB=446(LC 19)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
WEBS C -AB= -352/163
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. Il; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for vend loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) P, B, S. T, U, V, W, X,
Y, Z, AA, R. 0 except (jt=1b) AB=144.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSIITPI 1.
11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
0
Nes
russ ype
y
y
Kandlner5F7138DAVENPORT
77.081085T
1801
Monopitch
2
1
SPACING- 2-0-0
CSI.
DEFL.
in
floc)
Well
Job Reference (optanap
� �••�� o �•�wr. �����.+��• o.wusaunczuiumneKmousmesinn me Augg280936272017 PaQet
ID:RJgPDIMJCgRAkoOBRQTPgzkbO3-jXMwaElzhpSgm6XgrrAHprPnEQGJAl_NE?Rbl sy1012
11-0-0 Bb -8 73-5-4 20.2-0
8.8-72 e-8-12
11
Sxe = Scale = 1:65.7
E
7x10
85-72 6 13-5-4 20.2-0
0- -0 6-3 72 0-1'72 6-8-12 R.Ad2
3x4 =
Plate Offsets (X Y)-
113:0-4-0 .0-1-111, U-1:0-3-0.0-1-12)
TOP CHORD 2x4 DF 1800F 1.8E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E TOP CHORD
Sheathed or 6.0-0 oc pudins, except end verticals.
BOT CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 1800F 1.6E "Except"BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
61: 2x8 OF 1950F 1.7E or 2x8 OF SS, 32: 2x4 OF Stud/Std
"Except"
MiTek recommends that Stabilizers and required cross bracing
WEBS 2x4 OF Stud/Std
be installed during truss erection, in accordance with Stabilizer
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
floc)
Well
Ud
PLATES
GRIP
TCLL 35.0
Plate Grp DOL 1.15
TC 0.46
Vert(LL)
-0.04
G -H
>999
360
MT20
220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.22
Vert(TL)
-0.09
G -H
>999
240
MT20HS
165/148
BCLL 0.0 "
Rep Stress Incr YES
WB 0.43
Horz(TL)
0.02
J
n/a
n/a
BCDL 7.0
Code IRC2012/rP12007
(Matrix)
Wind(LL)
0.01
G
>999
240
Weight:119Ib
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 DF 1800F 1.8E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E TOP CHORD
Sheathed or 6.0-0 oc pudins, except end verticals.
BOT CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 1800F 1.6E "Except"BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
61: 2x8 OF 1950F 1.7E or 2x8 OF SS, 32: 2x4 OF Stud/Std
"Except"
MiTek recommends that Stabilizers and required cross bracing
WEBS 2x4 OF Stud/Std
be installed during truss erection, in accordance with Stabilizer
EV2: 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 180OF 1.6E
Installationuide.
OTHERS 2x4 OF Stud/Std
REACTIONS. (Ib/size) H=1077/0-5.8 (min. 0-1-8), B=347/0-3-0 (min. 0-1-8), J=598/0-3-8 (min. 0-1-8)
Max Horz 8=491 (LC 8)
Max UpliftH=-281(LC 8), J=-273(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD B -C=-287/234, C -D=-647/0, F -I=-160/397, E -I=-160/397
BOT CHORD C -H=.943/357, F -G=-237/467
WEBS C -G=-56/462, D -F=-457/230
NOTES -
1) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf BCDL=4,2psf; h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) All plates are MT20 plates unless otherwise indicated.
3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent wrath any other live loads.
4) "This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit
between the bottom chord and any other members.
5) Bearing at joint(s) J considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify, capacity of
bearing surface.
6) Provide mechanical connection (byothers) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=1b) H=281,
J=273.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
8) "Semi-rigid pilchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
rasa
fuss ype
y
KertchnerSF7B80AVENPORT
17.081085T
C01
Roof Special
1
7
CSI.
DEFL.
in
Job Reference (optional)
•--•••- ,.-•^•"•^--•-^�• esmausmes mc. me Nag La Ua:J6'2a 201]Pa�e1
ID:RJgP01 WsJCgRAkoOBR0TPgzkb03CjvinambS6DXNIIKJBh WL2xfJQSZviZNESKu WJy1011
-1- 67-13 13310 1911-8 2638 32-8-0 40-0-8 453-0 4
&7-13 Q7-13 6
7-13 54-1 7-4-8 7-4-8 5-2-8 -0
6x8 i
3x6 i 0
3x6 i HW1
3x6 i
7.00F12
3x6 4
5x12 MTZIHS% 3.5012
5x6 i
7x10 J
7x10 = M
3x6
5x8
7x10 J
5x6
Scale =181.5
� I J
5x12 MT20HSG K 4x5
5x12 MT20HS=
10.7-8 20.30 2638 32-8-0 40.0.8 4 4530
10.7-8 1Q1-8 541-8 7-0-8 7-0A 0. -12 4-11-12
Plate Offsets (X Y)-
[8:0-2-13,0-2-9], [E:0-3-0.0-2-51,
[F:0-64,0-1-121,
IK'0-9-8 0.2-121
11-:04-0 .0-3-01, (0'0-5-8 0-3-41
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
floc)
Well
Ud
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC
0.95
Vert(LL)
-0.56
N -O
>852
360
MT20
220/195
TCDL 7.0
Lumber DOL 1.15
BC
0.89
Vert(TL)
-1.12
N -O
>428
240
MT20HS
165/146
BCLL 0.0 '
Rep Stress Incr YES
WB
0.81
Horz(TL)
0.68
K
n/a
n/a
BCDL 7.0
Code IRC2012/TP12007
(Matrix)
Wind(LL)
0.29
N -O
>999
240
Weight: 227 lb
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 OF 1800F 1.8E or 2x4 OF No.1&Btr or 2x4 DF -N 1600F 1.6E TOP CHORD
BOT CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 1800F 1.6E
WEBS 2x4 OF 1800F 1,6E or 2x4 OF No.1&Blr or 2x4 DF -N 1800F 1.6E *EXcePt•BOT CHORD
W1,W2,W4,WB,W10: 2x4 OF Stud/Std
SLIDER Left 2x4 DF -N or DF 1800F 1,6E or No. 1&B 7-2-8
REACTIONS. (Ib/size) K=2596/0-5-8 (min. 0-2-12), B=2016/0-5-8 (min. 0.2-0)
Max Harz B=-321 (LC 6)
Max UpliftK=-474(LC 9), B=-390(LC 8)
Sheathed, except
2-0-0 oc pudins (3-4-8 max.): E -F.
Rigid ceiling directly applied or 5-10-7 oc bracing
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=-6233/1284, C -D=-5471/1050, D -E=-3717/603, E -F=-3139/586, F -G=-2863/464,
G -H=-2520/356, H -I=-143/674
BOT CHORD B -O=-1276/5514, N-0=-807/4326, M -N=-161/2425, L -M=-184/2156, K -L=-614/228,
I -K=-464/185
WEBS C -O=.738/378, D.O=-163/797, D -N=-1114/484, E -N=-162/1332, F -N=.241/1287, G-M=A84/438,
G -L=-952/171, H -L=-248/2636, H -K=-2332/457
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load noncencument with any other live loads.
6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Bearing at joint(s) B considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift aljoint(s) except (jl=11b) K=474,
B=390.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Graphical pudin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
0
was
Mae ype
yKanchnerSF788
DAVENPORT
17-081085T
CO2
Common SVudural Gable
1
1
SPACING- 2-0-0
CSI.
DEFL.
in
Job Reference (optional)
Scale =1:79.1
5x6 G
5x6 1
Aa N O P
AS w
516 = 5x6 =
� eur rxo —
A$
Plate Offsets (X.Y)—
fE:0-2-12,Edge1 IM:0-3-0 0-0-41
10:0-3-0
0-0-01 IY'0-2-12 Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
floc)
I/deft
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.08
Vert(LL)
0.00
AC
n/r
120
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.03
Vertji-)
0.00
AC
n/r
120
BCLL 0.0 '
Rep Stress Incr YES
WB 0.13
Horzji-)
0.01
AB
n/a
n/a
BCDL 7.0
Code IRC2012/TPI2007
(Matrix)
Weight: 328 Ib FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E TOP CHORD
BOT CHORD 2x4 OF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.8E
OTHERS 2x4 OF 180OF 1.8E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E'ExoepC80T CHORD
WEBS
ST7,ST8,ST9,ST10,ST11,ST17,ST78,ST19,ST20,ST21: 2x4 DF Stud/Sid
REACTIONS. All bearings 45-3-0
(lb) - Max Horz B=-321(LC 6)
Max Uplift All uplift 100 Ib or less at joint(s) B, AO, AP, AQ, AR, AT, AU, AV, AW, AX,
AY, AZ, AN, AM, AL, AJ, Al, AH, AG, AF, AE, AD, AB
Max Grav All reactions 250 Ib or less at joint(s) B, A0, AP, AQ, AR, AT, AU, AV, AW,
AX, AY, AZ, AN, AM, AL, AJ, Al, AH, AG, AF, AE, AD, AS
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B -C=-298/248, K -L=-124/283, L -M=-106/283, M -N=-67/288, N -O=-67/268, O -P=-67/288,
P -Q=-67/268, Q -R=-101/279, R -S=.93/255
Sheathed or 8-0.0 Dc pur ins, except
2-0-0 oc pudins (6-0-0 max.): M -Q.
Rigid ceiling directly applied or 10-0-0 oc bracing.
1 Row at midpt O -AO, N -AP, L -AQ, K -AR, J -AT, P -AN, RAM
, S -AL, T -AJ
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vul1=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf, h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 2-0-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0.0 wide will fit
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) B, AO, AP, AQ, AR,
AT, AU, AV, AW, AX, AY, AZ, AN, AM, AL, AJ, Al, AH, AG, AF, AE, AD, AS,
11) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSlrTPI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
13) Graphical puffin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Job
toss
was I ype
y
yKenchnerSF7138
DAVENPORT
17.08108ST
DO1
PiggYbatl Base
7
1
CSI.
DEFL.
in
(loc)
I/deg
Job Reference (optional)
5rn0 vv=S (iv.0-,0 FALLS), ,DAHO FALLS, iu 63402 a.uw admlaeutn MneKlnammes,Inc Tue Au99290936332017 Pagel
ID:RJgPDIMJCgRAkoOBRQTPgzkbO3-YhjBglgkHfrgUWd15kHh26en8rOSZ:M6ON2eAft Hy
-1-oq &]-13 133-10 1311.8 2538 237 -ii 34162 4048 42-116 45304�-3,6
t-0�&]-13 - S7-ia Fz13 54.1 4+3 I 826 Sza 2-n-0 2-3-8 fA�
Scale = 1:87.9
5x6 i
5x8 =
P O
5x8 3x4 11
42-11-8
10.1-0 20.30 2538 23)-1f 102 4668 4 0.53.0
fa4e 16f.a c6� 34csa ti°fr.4 i e
Plate Offsets (X ))-
[B:0-2-1 Ednel [C:0-4-0.0-3-0],
IE:0-3-0
0-2-5] [F:0-6-0,0-2-41.
IP:0-5410-2-81
rQ'0-3-0 0-3-01
IU:04-0 0-3-01
LOADING (pso
SPACING- 1-4-0
CSI.
DEFL.
in
(loc)
I/deg
Lid
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.62
Vert(LL)
-0.38
T -U
>999
360
MT20
220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.62
Vert(TL)
-0.74
T -U
>648
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.84
Horz(TL)
0.46
P
n/a
n/a
BCDL 7.0
Code IRC2012/FPI2007
(Matrix)
Wind(LL)
0.21
T -U
>999
240
Weight: 256 lb
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 OF No.1&Str or 2x4 DF -N 180OF 1.6E TOP CHORD
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 180OF 1.6E
WEBS 2x4 DF Stud/Sld'ExcepP
BOTCHORD
W3,W5,W6: 2x4 OF 180OF 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 180OF 116EBS
REACTIONS. (Ib/size) P=1742/0-5-8 (min. 0-1-14), B=1343/0-5-8 (min. 0-1-8)
Max Horz B=278(LC 8)
Max UpliftP=-359(LC 9), B=-247(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B -C=-3916/895, C -D=-3528/774, D -E=-2475/500, E -F=-2090/478, F -G=-1838/357,
G -H=-1553/262, H-1=.836/138, L.V=-77/268
BOT CHORD B.0=.1013/3405, T -U=-763/2880, S -T=-282/1607, R -S=-264/1556, Q -R=-134/817
WEBS C -U=-314/206, D -U=-81/414, D -T=-744/320, E -T=-155/876, F -T=-242/861, G -R=-829/180,
H -R=-167/959, H -Q= -1157/240.1 -Q= -231/1344,1 -P= -1663/407,1-L=.125/338
Sheathed or 2-8-8 oc pudins, except end verticals, and 2-0-0 Dc
pudins (4-3-13 max.): E -F, J -O. Except:
6-0-0 oc bracing: J -L
Rigid ceiling directly applied or 6-0-0 oc bracing.
1 Row at midpt I -P
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf, BCDL=4.2psf; h=25fl; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 Wde will ft
between the bottom chord and any other members.
6) Bearing atjoint(s) B considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
Dearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except (jt=1b) P=359,
B=247.
8) This truss is designed in accordance with the 2012 Intemalional Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/rPI 1.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) Graphical pudin representation does not depict the size or the orientation of the Purim along the top and/or bottom chord.
LOAD CASE(S) Standard
0
mss
runs ype
y
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E
Kartchner SF788 DAVENPORT
17481085T
E01
Roof Spedal
7
1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
Job Reference (optional)
---•_-- -- •----- o.uwe.'ul mamamunnlnausviea.Inc I ue Au2aua:Ja:3620l7 P28901
.�y ID:RJgPDIMJCgRAkoOBRQTPgzkbO3-U4gxF_r_oG5YJgnhD9J97Xk NevOlrPPrhXIFPyjpHW
rt l 7-6$ 1540-15 2.2
1-0.0 7 -BA 7-6-8 i 7-6-8 2-71-1
5x6 1 7.00 J2 Scale: 1K'=7'
3x9 11 1.5x4 I Safi = 48 = 1.5x4 11
Plate Offsets (X Y)-
rB:0-2-15 Edge1 [B:0-0-0,0-2-31.
[E:0-3-9.0-2-81,
rl:0-3-0 0-3-01
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E
BOT CHORD
WEBS 2x4 DF Stud/Sid *Except*
WEBS
W2,W4,W5: 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E
WEDGE
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/deg
Ud
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC
0.89
Vert(LL)
-0.17
B -J
>999
360
MT20
220/195
TCDL 7.0
Lumber DOL 1.15
BC
0.59
Vert(TL)
-0.30
B -J
>999
240
BCLL 0.0 •
Rep Stress Incr YES
WB
0.87
Horz(TL)
0.08
G
n/a
n/a
BCDL 7.0
Code IRC2012/TPI2007
(Matrix)
Wind(LL)
0.11
B -J
>999
240
Weight: 134 Ib
FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 DF 180OF 1.8E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E
TOP CHORD
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E
BOT CHORD
WEBS 2x4 DF Stud/Sid *Except*
WEBS
W2,W4,W5: 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E
WEDGE
Left: 2x4 DF Stud/Std
REACTIONS. (Ib/size) B=1343/0-5-8 (min. 0-1-8), G=1230/0-5-8 (min. 0-1-8)
Max Horz B=285(LC 4)
Max UpliftB=-321(LC 4), G=-294(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD B -C=-2728/541, C -D=-1690/342, D -E=-567/114, E -F=-521/140, F -G=-1223/295
BOT CHORD BJ= -721/2455, I -J=-723/2451, H -I=-431/1512
WEBS C -J=0/269, C -I=-1004/312, D-1=-4 314 5 6, D -H=-1329/399, F -H=-250/1006
Sheathed or 3-1-9 oc purlins, except end verticals
Rigid ceiling directly applied or 6-0-0 oc bracing.
1 Row at midpt D -H
MiTek recommends that Stabilizers and required cross bracing
be Installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Unbalanced root live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent vAth any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=1b) B=321,
G=294.
6) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI(TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
'UssmsS
ype
y
kenchnerSF]BB DAVENPORT
174810857
Got
Common
2
1
CSI.
DEFL.
in
(loc)
I/deb
Ud
Job Reference (opt' h
BMC WEST (IDPHO FALLS), IDAHO FALLS, 10 83402
4x5 II
Scale = 1:41.3
Plate Offsets (X Y)—
[B:0-24,0-1-81, IF:0-240-1-81
IH:0-3-0 0-3-01
LOADING (pso
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/deb
Ud
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.35
Vert(LL)
-0.12
H -I
>999
360
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.30
Vert(TL)
-0.18
H-1
>999
240
BCLL 0.0
Rep Stress Incr YES
WB 0.13
Horz(TL)
0.04
F
n/a
n/a
SCOL 7.0
Code IRC2012/rP12007
(Matrix)
Wind(LL)
0.04
B -I
>999
240
Weight: 96 lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.1&Btr or 2x4 DF -N 180OF 1.6E TOP CHORD
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E BOT CHORD
WEBS 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E •Except•
W2,W4: 2x4 OF Stud/Std
REACTIONS. (Ib/size) B=1164/0-3-8 (min. 0-1-8), F=1164/0-3-8 (min. 0-1-8)
Max Horz B=-184(LC 6)
Max UpliflB=-228(LC 8), F=-228(LC 9)
FORCES. (Ib) -Max Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=-1702/303, C -D=-1473/326, D -E=-1473/327, E -F=-1702/303
BOT CHORD B -I=-292/1370, IJ= -90/896, J -K=-90/896, H -K=-90/896, F -H=-169/1370
WEBS D -H=-166/585, E -H=-429/236, D -I=-166/585, C -I=-429/236
Sheathed or 4-10-5 Dc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf, h=25ff; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except Qt=lb) B=228,
F=228.
6) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
0
cuss
fuss ype
K Rohner SF788DAVENPORT
17-081085T
G02
Common
1
1
LOADING (psf)
SPACING- 2-0-0
CSI.
Job Reference (optional)
3x9 � 3X4 =5x6 = 3X4 O
---n•-•^•-•••-wlv-•--;" o.uwsdunozuiomneKmausmes•mc iue Aug290936372017 Paggel
ID:RJgPDI WsJCgRAkoOSROTPgzkbO3-RSyigfiFKtLFy8x3KaMdOyp W9SfnVwsil70sJHyjOHu
5-5-14 10 -it -02 i8S10 21-11-8
5-5-14 5514 55-14 5-5-14
4x5 II
Scale =1:40.1
I
Plate ORsets(XY1—
fA:0-240-1-81 IE.0-2-40-1-81
IF:0-3-OOJ-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)/deo
L/d
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC
0.36
Vert(LL)
-0.11
F -G
>999
360
MT20
220/195
TCDL 7.0
Lumber DOL 1.15
BC
0.33
Vert(TL)
-0.17
F -G
>999
240
BCLL 0.0 `
Rep Stress Incr YES
WB
0.13
Horz(TL)
0.04
E
We
n/a
BCDL 7.0
Code IRC2012rrP12007
(Matrix)
Wind(LL)
0.05
A -G
>999
240
Weight: 93 lb
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 OF 1800F 1.6E or 2x4 DF No.1&Bir or 2x4 DF -N 180OF 1.6E TOP CHORD
BOT CHORD 2x4 OF 180OF 1.6E or 2x4 DF No.1&Str or 2x4 DF -N 180OF 1.6E BOT CHORD
WEBS 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E *Except*
W204: 2x4 DF Stud/Std
REACTIONS. (Ib/size) A=1062/0-3-8 (min. 0-1-8), E=1062/0-3-8 (min. 0-1-8)
Max Horz A=-168(LC 4)
Max UpliOA=-195(LC 8), E=-195(LC 9)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD A -B=-1723/310, B -C=-14931334, C -D=-1493/334, D -E=-1723/310
BOT CHORD A.G=-310/1391, G -H=-103/906, H -I=-103/906, F -I=-103/906, E -F=-196/1391
WEBS C -F=-172/598, D.F=-437/239, C -G=-172/597, B.G=-437/239
Sheathed or 4-9-7 oc pudins.
Rigid ceiling directly applied or 10-0-0 oc bracing
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance With Stabilizer
Installation guide.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf, BCDL=4.2psf, h=25tt; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will 8t
between the bottom chord and any other members, vnlh BCDL = 7.Opsf.
5) Provide mechanical Connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at)oint(s) except Qt=1b) A=195,
E=195.
6) This truss is designed in accordance vAth the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSIrrPI 1.
7) "Semi-rigid pitchbreaks With fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
mss
ruse ype
y
y
"'tchnerS"138DAVENPORT
17-081085T
G03
GABLE
i
1
CSI.
DEFL.
in
(loc)
I/deg
Ud
Job Reference (optional)
�'•'�^` , '.'^••w. . a.uw s JN it Luio Ml lex ln0u5Nes, Inc. I US Aug 29 09:36 39 2017 PB99ei
ID:RJgPDI WSJCgRAkoOBROTPgzkbO3-Nr4S5LvVsVbzCR4SS?O51NuwAGP?zrB4mJVzOAyJOHs
-1-0-0 10-11-12 21-11-8 2-11
1-0-0 10-11-12 1111-12
4x5 =
""' V J T R R n o n ni 3x4 =
5x6 =
Scele =1:43.4
Plate Offsets (X,Y)—
[R:0-3.0,0-3-01
LOADING lost)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/deg
Ud
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.07
Ven(LL)
-0.00
L
n/r
120
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.03
Ven(TL)
0.00
L
n/r
120
BCLL 0.0
Rep Stress Incr YES
WB 0.12
Horz(TL)
0.00
L
n/a
n/a
BCDL 7.0
Code IRC2012rTP12007
(Matrix)
Weight:112110 FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 OF 1800F 1.6E or 2x4 OF No. 1&Btr or 2x4 DF -N 1800F 1.6E TOP CHORD Sheathed or 8-0-0 oc purlins.
BOT CHORD 2x4 OF 1800F 1.6E or 2x4 OF No. 1&Str or 2x4 DF -N 1800F 1.6E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 OF Stud/Std MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
REACTIONS. All bearings 21-11-8. Installation guide.
(Ib) - Max Horz B=-184(LC 6)
Max Uplift All uplift 100 lb or less atjoint(s) B, S, T, U, 0, P. 0, L except V=-105(LC 8), N=-105(LC 9)
Max Grav All reactions 250 lb or less at joint(s) B, R, S, T. U, Q, P. O, L except V=269(LC 19), N=269(LC 20)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for vend loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent with any other live loads.
8) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wade will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, S, T, U, Q, P. O, L
except (jt=1 b) V=105, N=105,
10) This truss is designed in accordance with the 2012 1ntemational Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/!PI 1.
11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
fuss
ruse ype
y
KanWner SF88 DAVENPORT
17.0810857
G04
Common Gir4er
1
2
Job Re(fence(optionall
11
G
.1-1m m iomnert inausmes, inc, me Au 2a09136:412017 Page
ID:RJgPDIMJCgRAkoOBRQTPgzkbO3JDCDW1wtO6MRIEgZPQZNn_ F3z4RYIIDd_4S2y)OHq
55.14 10-11-12 16-510 21-11-8
55.14 5-5-14 5-5-14 55-14
45 11
3x8 =
3x8 II 7x10 = 3x8 11
55-14 10-11-12 16510 21-11.8
SS14 5_S1d F_F-II
Scale =1:40.7
i
Plate Offsets (X.Y)-
[G:0 -&O04-8]
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
PLATES
GRIP
TCLL 35.0
Plate Grip DOL
1.15
TC 0.36
Vert(LL)
-0.14
F -G
>999
360
MT20
220/195
TCDL 7.0
Lumber DOL
1.15
BC 0.57
Vert(TL)
-0.21
F -G
>999
240
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.91
Horz(TL)
0.07
E
We
n/a
BCDL 7.0
Code IRC2012/TP12007
(Matrix)
Wind(LL)
0.04
G -H
>999
240
Weight: 2271b
FT=20h
LUMBER -
TOP CHORD 2x4 OF 180OF 1.6E or 2x4 OF No. 1&Btr or 2x4 DF -N 180OF 1.6E
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF Stud/Std
REACTIONS. (lb/size) A=4180/0-3-8 (min. 0-2-4), E=4132/0-3-8 (min. 0-2-3)
Max HorzA=166(LC 26)
Max UpliftA=-342(LC 8), E=-340(LC 9)
BRACING -
TOP CHORD Sheathed or 5-1-5 oc purlins.
BOT CHORD Rigid Ceiling directly applied or 10-0-0 oc bracing.
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD A -B=.6915/550, B -C=-4634/415, C -D=.4634/415, D -E=-6904/551
BOT CHORD A -I=-516/5889, W=-516/5889, HJ= -516/5889, H -K=-516/5889, K -L=-516/5889,
L -M=-516/5889, G -M=-516/5889, G -N=-404/5879, N -O=-404/5879, O -P=-404/5879,
F -P=-004/5879, F -Q=404/5879, Q -R=-404/5879, E -R=-404/5879
WEBS C -G=-277/4114, D -G=-2309/322, D -F=-50/1845, B -G=-2321/322, B -H=-50/1855
NOTES -
1) Special connection required to distribute top chord loads equally between all plies.
2) 2 -ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords Connected as follows: 2x4 -1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 -1 row at 0-9.0 oc.
3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
4) Unbalanced roof live loads have been considered for this design.
5) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf, h=25ft; Cat. ll; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and night exposed ; Lumber DOL=1.33 plate grip DOL=1.33
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
7) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 vide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except 0t=11b) A=342,
E=340.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Use Simpson Strong -Tie LUS24 (4-1 Od Girder, 2-1 Od Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max, starting at
1-10-12 from the left end to 19-10-12 to connect truss(es) J01 (1 ply 2x4 DF -N or DF) to front face of bottom chord.
12) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
Continued on page 2
JOID
I russ
Inuss iype
Oty
ply
Kenahner U768 DAVENPORT
17-0 1085T
G04
Common Girder
1
2
Job Reference (optional)
^�^� ^� r. ^•��•���^�•3 IW 1. eUlo mu eK lnUVenle3, inc me qu 2a UY3tl:412017 Paget
ID:RJ9PDIMJCgRAkoOBRQTPgzkbO3JDCDWiwI06ihRIEgZPQZNn_ F3z4RVIIDU_4S2yj Hq
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Unifonn Loads (plf)
Vert: A -C=-84, C -E= -84,A -E=-14
Concentrated Loads (Ib)
Vert: 1=-619(F) J= -619(F) K= -619(F) L= -619(F) M= -619(F) N= -619(F) 0=-619(F) P= -619(F) Q= -619(F) R= -619(F)
Job
Ns3
rus4 yp¢
y
BOT CHORD 2x4 DF 180OF 1.8E or2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E BOT CHORD
KQf IneBF]98 DAVENPORT
17.0810857
H 11
GABLE
1
i
CSI.
DEFL. in
floc)
I/deg
L/d
PLATES GRIP
Job Reference (optional
BMC WEST(IDAHO FALLS), IDAHO FALLS, ID 83402 ID:RJgPDIVJCgRAk00BRQTPgBz.OkbbO0a3-nO1m52b0jN16z0gCL. Y3vpli7es, Inc Tue WAug 2
9 0936 42 2017 Part
22-7-7 25-6-e SHjd7VyjHp1-000
22-7-7 2-11-1
4x5-- 7.0012 Scale =1:49.3
4.00 F12
3x4 = Z Y X W V U T S ft 0 p O
3X8 II 5x6 =
Plate Offsets (X Y)-
1121:0-0-0,0-1-31, IB:0-2-15 Edoel
[G:0-3-0,0-3-01. IL:0-2-15 0-2-41
[U:0-3-0.0-3-01
BOT CHORD 2x4 DF 180OF 1.8E or2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 DF Stud/Std
*Except*
MiTek recommends that Stabilizers and required cross bracing
LOADING (pso
SPACING- 2-0-0
ST2: 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E
CSI.
DEFL. in
floc)
I/deg
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.19
Vert(LL) -0.00
A
n/r
120
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.09
Vert(TQ 0.01
A
n/r
120
BCLL 0.0 '
Rep Stress Incr YES
WB 0.16
Hoa(TL) 0.00
O
n/a
n/a
BCDL 7.0
Code IRC2012ITP12007
(Matrix)
Weight:1531b FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.8E TOP CHORD
Sheathed or 6-0-0 oc pudins, except end verticals.
BOT CHORD 2x4 DF 180OF 1.8E or2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 DF Stud/Std
*Except*
MiTek recommends that Stabilizers and required cross bracing
OTHERS 2x4 DF Stud/Std
be installed during truss erection, in accordance with Stabilizer
ST2: 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E
Installation guide.
WEDGE
Left: 2x4 DF Stud/Std
REACTIONS. All bearings 25-6-8
(lb) - Max Horz 8=285(LC 4)
Max Uplift All uplift 100 lborless at joint(s) O, B, Q, R, S. T. U, V, W. X, Y, P except Z=-146(LC 8)
Max Grav All reactions 250 Ib or less at joint(s) O, Q, R. S. T. U, V. W. X, Y. P except B=286(LC 1), Z=446(LC
19)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD B -C=-267!71
WEBS C -Z=-352/165
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf, h=25ft; Cat. 11; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) = This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 10010 uplift at joint(s) O, B, Q, R, S, T, U, V.
W, X, Y. P except (jt=lb) Z=146.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
11) "Semi-rigid pitchbreaks With fixed heels' Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
Nss
Nss ype
y
y
Kartanar8F768DAVENPORT
17.081095T
J01
Jerk -Closed
10
1
Plate Grip DOL
1.15
TC 0.53
Vert(LL)
-0.04
D -E
Job Reference (optional)
6MG VV S (I OFALLS), IDAHO rnup..0 -02 6.0005 JUI 152016 Meek IndusMes, Inc Tue Aug 2909:36:442017 Pe e1
ID:RJgPDI WsJCQRAkoOBRQTPgzkbO3-kotL63yeh1 EGICzPEY_G?QcgrH3Ge5ZkvbCk3NyjOHn
8$$i 18-1-0 1 -8
8-88 6-a 0-"
5x
3x4 II
C
F E D
1.5x4 11 4x5 = 3x8 /i
Scale = 1:53.8
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
In
(loc)
IldeB
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL
1.15
TC 0.53
Vert(LL)
-0.04
D -E
>999
360
MT20 220/195
TCDL 7.0
Lumber DOL
1.15
BC 0.22
Vert(TQ
-0.08
D -E
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.17
Horz(TQ
-0.01
D
n/a
n/a
BCDL 7.0
Code IRC2012/TPI2007
(Matrix)
Wind(LL)
0.01
E
>999
240
Weight: 801b FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.8E TOP CHORD
BOT CHORD 2x4 DF 180OF 1.8E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E BOT CHORD
WEBS 2x4 DF Stud/Std'Except* WEBS
EV2,W3: 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E
REACTIONS. (Ib/size) F=633/Mechanical, D=633/0-1-8 (min. 0-1-8)
Max Horz F=307(LC 8)
Max UpliftF=-21(LC 8), D=-289(LC 8)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shovm.
TOP CHORD A -F=-592/42, A -B=-627/0
BOT CHORD E -F=-332/152, D -E=-224/446
WEBS A -E=0/387, B -D=-575/291
Sheathed or 6-0-0 oc purlins, except end verticals
Rigid ceiling directly applied or 10-0-0 oc bracing.
1 Row at midpl C -D, B -D
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
In
quitle.
NOTES -
1) Wind: ASCE 7.10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf, h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument vrith any other live loads.
3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 Wde vnll fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Bearing at joint(s) D considers parallel to grain value using ANSI/1-PI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) D.
7) Provide mechanical connection (byothers) of truss to bearing plate capable of Wthstanding 100 lb uplift atjoint(s) F except Ot=lb) D=289.
8) This truss is designed in accordance vnth the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model ores used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
.••�••-� o •�•A
cuss
ru55 ype
Q y
plynerSF7MDAVENPORT
I/deo
17481085T
Jo1C
GABLE
2
1
TC 0.37
Vert(LL)
n/a -
n/a
999
MT20
Job Referent (optionab
�r..��..�•�.......�•••••�. 0.uw a awiozbMeKinau=ss,inc iueAq909:36452017 Pa
3- Oe1
ID:RJgPDIWsJCgRAko08RQTPgzkb0C7RjM02GSKM7wMYwFVXd8uoNFNYJt8FyHcpyjHm
13-1-0 -8
131-0 0.-S
4x8
5x12 MT20HS I
Scale =1:49.6
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/deo
Ud
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.37
Vert(LL)
n/a -
n/a
999
MT20
2201195
TCDL 7.0
Lumber DOL 1.15
SC 0.36
Vert(TL)
n/a -
n/a
999
MT20HS
165/146
BCLL 0.0 '
Rep Stress Incr YES
WB 0.14
HOrz(TL)
-0.00 1
n/a
We
BCDL 7.0
Code IRC2012rTP12007
(Matrix)
Weight: 99 lb
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 OF 180OF 1.8E or 2x4 OF No. t&Btr or 2x4 DF -N 180OF 1.6E TOP CHORD
Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD 2x4 OF 180OF 1.6E or 2x4 DF No. t&Btr or 2x4 DF -N 1800F 1.6E BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 OF 180OF 1.6E or 2x4 DF No.1 &Btr or 2x4 DF -N 1800F 1.6E WEBS
1 Row at midpt H -I, GJ
OTHERS 2x4 OF Stud/Std *Except'
MiTek recommends that Stabilizers and required cross bracing
ST6,ST7: 2x4 DF 180OF 1.6E or 2x4 DF NoA&Btr or 2x4 DF -N 180OF 1.6E
be installed during truss erection, in accordance with Stabilizer
Installation Guide.
REACTIONS. All bearings 13-1-0.
(Ib) - Max Horz P=307(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) I, L, K, J except P=-166(LC 6), 0=-549(LC 8),
M=-103(LC 8)
Max Grav All reactions 250 lb or less at joint(s) I, N, M, L, K, J except P=530(LC 8), 0=331 (LC 15)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD A -P=-322/104, A -B=-424/159, B -C=-256/101
WEBS B -O=-232/317
NOTES -
1) Wind: ASCE 7-10; Vul1=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. Il; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) All plates are MT20 plates unless otherwise indicated.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
7) Gable studs spaced at 2-0-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) I, L, K, J except
(jt=lb) P=166, 0=549, M=103.
11) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
o
mss
Nss ype
y
y
xertchner3F7B6 DAVENPORT
17481085T
J02A
GABLE
1
1
CSI.
DEFL.
in
(too)
/dell
L/d
JabR ( rence(optiona0
umu rrcm y rALLo),,UmHU I=nua. ,u 6, 02 5.000 s J01152016 MITek IneusMes, Inc Tue Au ee 29 09.36:46 2017 Pa e 1
ID:RJgPDIWSJCgRAkoOBROTPgzkb03-g896Zk ut)eU_XW7oMZOk4rh3i4nL67m1Nvhg8Gy?OHI
3 -BA 6A-12 1"'
3-8.8 4114 534
3x4- u o. I"
J I H
3.5-0 318f8 8-12 18-8-0
:1-511 n.ifl d.a.d F 41
3x4 =
Y
I
Scale =1:57.2
Plate Offsets(X,Y)-
fB:0-1-15.Edge1 IS:0-1-13 0-0-121
TOP CHORD 2x4 OF 1800F 1.6E or 2x4 OF No. 1&Btr or 2x4 DF -N 1800F 1.6E TOP CHORD
Sheathed or 6-0-0 oc pudins, except end verticals.
BOT CHORD 2x4 OF 1800F 1,6E or 2x4 OF No. i&Btf or 2x4 DF -N 1600F 1.6E BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 OF Stud/Std
MiTek recommends that Stabilizers and required cross bracing
OTHERS 2x4 DF Stud/Std'Except'
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL.
in
(too)
/dell
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.37
Vert(LL)
-0.01
E -F
>999
360
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.11
Vert(FL)
-0.03
E -F
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.19
Horz(TL)
0.03
Y
n/a
n/a
BCDL 7.0
Code IRC2012rFP12007
(Matrix)
Wind(LL)
0.01
F
>999
240
Weight:116lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 OF 1800F 1.6E or 2x4 OF No. 1&Btr or 2x4 DF -N 1800F 1.6E TOP CHORD
Sheathed or 6-0-0 oc pudins, except end verticals.
BOT CHORD 2x4 OF 1800F 1,6E or 2x4 OF No. i&Btf or 2x4 DF -N 1600F 1.6E BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 OF Stud/Std
MiTek recommends that Stabilizers and required cross bracing
OTHERS 2x4 DF Stud/Std'Except'
be installed during truss erection, in accordance with Stabilizer
BLi: 2x4 OF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E
Installation guide.
REACTIONS. All bearings 3-8-8 except (jt=length) Y=0-3-8.
(Ib) - Max HorzJ=311(LC 8)
Max Uplift All uplift 100 Ib or less at joint(s) H, J except G=-277(LC 8), Y=-217(LC 8)
Max Grav All reactions 250 lb or less at joint(s) H, H, J, I except G=686(LC 1), Y=445(LC
1)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B -C=-018/0, E -X=-131/294, D -X=-131/294
BOT CHORD B -G=-655/333, E -F=-168/303
WEBS C -E=-305/170, 8-J=-286/129, B -F=-24/298
NOTES -
1) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91mph; TCDL=4.2psf, BCDL=4.2psf, h=25ft; Cat. ll; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wand loads in the plane of the truss only. For studs exposed to vend (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) This truss is not designed to support a ceiling and is not intended for use where aesthetics are a consideration.
4) All plates are 1.5x4 MT20 unless otherwise Indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members.
8) Bearing at joint(s) G, Y considers parallel to grain value using ANSUFPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) H, J except Qt=lb)
G=277, Y=217.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
was
Truss Type
Oty
KanchnerSPB8 DAVENPORT
17-061085T
PBO2
Piggybaok
9
1
CSI.
DEFL.
in
(loc)
Udell
Ud
Job Reference (optional)
=MCAES (1 0 FALLS),!DAHO FALLS, iD 6.402 a.Wua"'2'u1e M1lexinguSalea,InC. Tue Aug 2909: 38: 482017 Pagel
2-8-0 ID:RJgPDIMJCgRAkoOSRQTPgqzzkbO3r 7s_Q08kFkhngHAT02CSGmUbuUiaxDKgCAxC8ylOHj
2-M 2-8-0
3x4 =
2x4 =
2x4 =
Scale = 1:11.5
Plate Offsets (X Y)—
IC:0-2-0 Edge]
LOADING (psf)
SPACING- 14-0
CSI.
DEFL.
in
(loc)
Udell
Ud
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.03
Vert(LL)
0.00
D
n/r
120
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.06
Vert(TL)
0.00
E
n/r
120
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(TL)
0.00
D
n/a
n/a
BCDL 7.0
Code IRC2012rrP12007
(Matrix)
Weight: 13 lb FT=20%
LUMBER -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E
BOT CHORD 2x4 DF 180OF 1.8E or 2x4 DF No.1&Bt(or 2x4 DF -N 1800F 1.6E
REACTIONS. (Ib/size) B=150/3-8-2 (min. 0-1-8), D=150/3-8-2 (min. 0-1-8)
Max Horz B=-24(LC 6)
Max UpliftB=-32(LC 8), D=-32(LC 9)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
BRACING -
TOP CHORD Sheathed or 511-1 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf h=25ft; Cat. II; Exp C; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 pet bottom chord live load nonconcument with any other live loads.
5) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) B, D.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
8) "Semi-rigid pilchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
LOAD CASE(S) Standard