Loading...
HomeMy WebLinkAboutFIRE ALARM SUBMITTAL - 17-00312 - 525 S Center St - BYUI - Hart Building - Remodel FIRE CONTROL INSTRUMENTS-GAMEWELL-BOSCH 1481 SOUTH MAJOR STREET S.L.C., UT 84115 P. 801-468-8300 F. 801-468-8305 Wellness Center Hart Building BYU-Idaho Fire Alarm System Submittal August 23, 2017 WELLNESS CENTER HART BUILDING BYU-IDAHO FIRE ALARM SYSTEM SUBMITTAL Equipment Manufacturer: Gamewell-FCI Authorized Distributor: Nelson Fire Systems 1481 South Major Street Salt Lake City, UT 84115 801-468-8300 Data Sheet Part No. Description Gamewell-FCI MS-7AF Addressable Pull Station Gamewell-FCI SWL Strobe Only – Wall Mount Gamewell-FCI P2WL Horn/Strobe – Wall Mount Gamewell-FCI PC2WL Horn/Strobe – Ceiling Mount Gamewell-FCI HPFF8 NAC Power Supply (Existing) GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0616 Rev. E page 1 of 2 MS-7 Series Non-Coded, Manual Fire Alarm Stations APPROVED FM 3023594 SIGNALING 7150-1703:0119 7150-1703:0170 7150-1703:0109 S2465 MEAApproved 67-02-E Vol.VIII Description The Gamewell-FCI, MS-7 Series manual fire alarm sta- tions are available in a wide variety of configurations. The Stations comply with the Americans with Disabilities Act (ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All stations have a key lock/reset which is keyed alike with Gamewell-FCI fire alarm control panels and other manual fire alarm stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti® Series addressable station is a dou- ble action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The sta- tion features screw terminals. MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable station is a single action station designed for installation in the signal- ing line circuit of Gamewell-FCI analog addressable con- trol panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The sta- tion features screw terminals. The Velociti® Series stations use a communication proto- col that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and focuses on the single device. The net effect is response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action station is used with conventional fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. Features • Addressable stations compatible with all Gamewell-FCI analog addressable fire alarm controls • Conventional stations suitable for use with any UL ® Listed control panel • Both single and double action stations available • Tumbler lock for test and reset keyed alike with Gamewell-FCI controls • Surface or semi-flush mounting • Shock and vibration resistant • Stations (MS-7LOB) Listed for outdoor applications • Complies with ADA pull force requirements *Only the red LED is operative in panels that do not oper- ate in Velociti mode. MS-7 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0616 Rev. E page 2 of 2 www.gamewell-fci.com MS-7S Single Action Station The MS-7S single action station is used with conventional fire alarm control panels. It features a set of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action station similar to the MS-7 station, with the additional feature of both English and Spanish instructions molded into the unit. MS-7LR Dual-action Agent Release Station The MS-7LR is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems. It features a set of single pole contacts and screw terminals for connection to an ini- tiating circuit. MS-7LRA Agent Release Station with Abort The MS-7LRA is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabil- ities are required. It consists of an MS-7LR mounted on a plate with an abort switch and LED indicators for system normal, and system activated status. MS-7LOB Double Action Station (Listed for Outdoor Applications) The MS-7LOB station must be mounted on a Model SB-I/O backbox. In retrofit applications, the station is UL Listed for use with the WP-10 backbox. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-7 interior stations may be surface mounted or semi-flush mounted on a standard double-gang, or 4-inch (10.2 cm) square electrical box. An optional trim ring (BG12TR) may also be used for semi-flush mounting. NYC-Plate The NYC-Plate provides the backplate for the manual pull station. (See Figure 1). Figure 1 NYC-Plate Specifications Material:Lexan® Contact Ratings:0.25 amps. @ 30 VAC/VDC (resistive) Dimensions:5 5/8” H x 4 1/4” W x 1 1/4” D (14 x 10.1 x 3.2 cm) Operating Temperature (MS-7AF, MS-7ASF):32° to 120° F (0° to 49° C) (MS-7LOB):-30° to 150° F (-35° to 66° C) Relative Humidity (MS-7AF, MS-7ASF):10 to 93% (non-condensing) (MS-7LOB):85% ± 5% @ 86° ± 3.6° (30° ± 2° C) Alarm Current:.0030 amp. 0.007 for LED Supervisory Current (MS-7AF, MS-7ASF):.00030 amps. Ordering Information Part Number Description MS-7 Double action station MS-7AF**Velociti addressable double action station MS-7ASF**Velociti addressable single action station MS-7S Single action station, wire leads MS-7SP Double action station, English and Spanish instructions MS-7LR Agent release station, dual-action MS-7LRA Agent release station with abort switch, LED indicators, dual- action MS-7LOB Double action station, outdoor use (Includes SB-I/O - Indoor/outdoor use backbox) SB-I/O Indoor/outdoor use backbackbox SB-10 Surface backbox BG12TR Trim ring for semi-flush mount, plastic NY-PLATE NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2016 by Honeywell International Inc. All rights reserved www.gamewell-fci.com 9021-60929 Rev. A page 1 of 4 Indoor Selectable-Output Horns, Strobes, and Horn Strobes for Wall Applications L-Series Indoor Horns, Strobes, and Horn Strobes APPROVED FM SIGNALING PENDING Description The L-Series audible visible notification products offer the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. In addition, this product includes lower current draws and a modern aesthetic design which reduce installation times and maximize prof- its. The following devices offer a variety of design options, so that the L-Series can be used for any application requirement. • White and red plastic housings. • Standard and small footprint devices. • Plain, FIRE, and FUEGO-printed devices. Similar to the entire L-Series product line, the wall-mount horns, strobes, and horn strobes include a variety of fea- tures that increase their application versatility while simpli- fying the installation. All devices offer a plug-in design so that there is minimal intrusion into the backbox. These fea- tures make installations fast and foolproof while eliminating costly and time-consuming ground faults. To further simplify the installation and protect devices from construction damage, the L-Series uses a mounting plate for all standard and compact models that include an on- board shorting spring. This feature allows Installers to test wiring continuity before the device is installed. Installers can also easily adapt devices to suit a wide range of application requirements using the following fea- tures: • Field-selectable candela settings. • Automatic selection of 12- or 24-volt operation. • Rotary switch for horn tones with two volume selections. L-Series Specifications Architect/Engineer Specifications General The L-Series standard horns, strobes, and horn strobes shall mount to any of the following enclosures: • standard 2 x 4 x 1 7/8-inch backbox • standard 4 x 4 x 1 1/2-inch backbox • 4-inch octagon backbox • double-gang backbox The L-Series compact products shall mount to a single- gang 2 x 4 x 1 7/8-inch backbox. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, the L-Series products, when used with the Sync•Circuit, Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. Features • Listed for wall mounting only. • Offers small profile devices for horns and horn strobes. • Provides an automatic selection of 12- or 24-volt operation at 15 and 30 candela. • Supports a rotary switch for horn tone and two volume selections. • Produces horn rated at 88+ dBA at 16 volts. • Uses field-selectable candela settings on wall units: - 15 - 30 - 75 - 95 - 110 - 135 - 185 • Includes a mounting plate for all standard and all com- pact wall units. • Contains a mounting plate with a shorting spring that checks the wiring continuity before device installation. • Features a plug-in design with minimal intrusion into the backbox. • Designed with a tamper-resistant construction. • Built with an updated modern design. • Supports electrical compatibility with the existing SpectrAlert and the SpectrAlert Advance products. • Compatible with System Sensor synchronization protocol. Wall Horns/Horn Strobes GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 page 2 of 4 www.gamewell-fci.com 9021-60929 Rev. A L-Series Specifications (Continued) Architect/Engineer Specifications (Continued) General (Continued) When it is used with the Sync•Circuit Module, the following occur: • 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. • 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. The Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have the following field-selectable candela settings: •15•30•75•95 •110 •135 •185 Strobe The strobe shall be an L-Series Model _______ listed to UL Standard 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appli- ances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be an L-Series Model _______ listed to UL Standard 1971 and UL Standard 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audible options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a Sync•Circuit model MDL3 listed to UL Standard 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch backbox. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy-chaining two or more synchroniza- tion modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature:32°F to 120°F (0°C to 49°C) Humidity Range:10 to 93% non-condensing Strobe Flash Rate:1 flash per second Nominal Voltage:Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2:8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) Sync Module:8.5 to 17 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge:12 to 18 AWG Wall-Mount Dimensions (including lens):5.6 L × 4.7 W × 1.25 D (143 mm L×119 mm W × 32 mm D) Compact Wall-Mount Dimensions: (including lens) 5.26” L x 3.46” W x 1.93” D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions:5.6 L × 4.7 W × 1.25 D (143 mm L×119 mm W × 32 mm D) Compact Horn Dimensions:5.25” L x 3.45” W x 1.25” D (133mm L x 88mm W x 32mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 cd and 30 cd. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60929 Rev. A page 3 of 4 UL Current Draw Table 1 lists the UL maximum Strobe current draw. Table 2 lists the UL maximum Horn current draw. Candela 8-17.5 Volts 16-33 Volts FWRDC DC Candela Range 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 Table 1: UL Maximum Strobe Current Draw (mA RMS) Sound Pattern dB 8-17.5 Volts 16-33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 Table 2: UL Max. Horn Current Draw (mA RMS) UL Current Draw Data Table 3 lists the maximum UL Current Draw (mA RMS) allowed for 2-Wire Horn Strobes, candala range (15-115cd). Horn Strobe Tones and Sound Output Data Table 4 lists the horn strobe tones and sound output data. DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd EM Temp Hi 98 158 54 74 121 142 162 196 245 EM Temp Low 93 154 44 65 111 133 157 184 235 EM Cont Hi 106 166 73 94 139 160 182 211 262 EM Cont Low 93 156 51 71 119 139 162 190 239 3.1K Temp Hi 93 156 53 73 119 140 164 190 242 3.1K Temp Low 91 154 45 66 112 133 160 185 235 3.1K Cont Hi 99 162 69 90 135 157 175 208 261 3.1k Cont Low 93 156 52 72 119 138 162 192 242 16V FWR FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd EM Temp Hi 83 107 156 177 198 234 287 EM Temp Low 68 91 145 165 185 223 271 EM Cont Hi 111 135 185 207 230 264 316 EM Cont Low 79 104 157 175 197 235 283 3.1K Temp Hi 81 105 155 177 196 234 284 3.1K Temp Low 68 90 145 166 186 222 276 3.1K Cont Hi 104 131 177 204 230 264 326 3.1k Cont Low 77 102 156 177 199 234 291 Table 3: UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Candela Range (15–115 cd) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts F W R DC DC 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9 Coded High 85 90 90 10 3.1 KHz Coded High 84 89 89 Table 4: Horn Strobe Tones and Sound Output Data GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 page 4 of 4 www.gamewell-fci.com 9021-60929 Rev. A L Series Dimensions Figure 1 Compact Combo L Series Dimensions Figure 3 Standard Combo L-Series Ordering Information Wall Horn Strobes Part Number Description P2RL 2-Wire, Standard Horn Strobe, Red P2WL 2-Wire, Standard Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Compact Horn Strobe, White P2RL-P 2-Wire, Standard Horn Strobe,Red, Plain P2WL-P 2-Wire,Standard Horn Strobe,White,Plain P2RL-SP 2-Wire,Standard Horn Strobe,Red, FUEGO P2WL-SP 2-Wire, Standard Horn Strobe, White, FUEGO Wall Strobes SRL Standard Strobe, Red SWL Standard Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Standard Strobe, Red, Plain SWL-P Standard Strobe, White, Plain SRL-SP Standard Strobe, Red, FUEGO SWL-CLR-ALERTStandard Strobe, White, ALERT L Series Dimensions Figure 2 Compact Horn L Series Dimensions Figure 4 Standard Horn L-Series Ordering Information Horns Part Number Description HRL Standard Horn, Red HWL Standard Horn, White HGRL Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Standard Wall Surface Mount Backbox, Red SBBWL Standard Wall Surface Mount Backbox, White SBBGRL Compact Wall Surface Mount Backbox, Red SBBGWL Compact Wall Surface Mount Backbox, White Notes: All -P models have a plain housing (no “FIRE” marking on cover). All -SP models have “FUEGO” marking on cover. All -ALERT models have “ALERT” marking on cover. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2016 by Honeywell International Inc. All rights reserved www.gamewell-fci.com 9021-60928 Rev. A page 1 of 4 Indoor Selectable-Output Strobes and Horn Strobes for Ceiling Applications L-Series Indoor Strobes and Horn Strobes APPROVED FM SIGNALING PENDING Description The L-Series audible visible notification products offer the most versatile and easy-to-use product line of horns, strobes, and horn strobes in the industry. This product includes lower current draws and a modern aesthetic design which reduce installation times and maximize prof- its. In addition, the L-Series offers white and red plastic housings and wall and ceiling mounting options. Similar to the entire L-Series product line, the ceiling- mount strobes and horn strobes include a variety of fea- tures that increase their application versatility while simpli- fying the installation. All devices offer a plug-in design so that there is minimal intrusion into the backbox. These fea- tures make installations fast and foolproof while eliminating costly and time-consuming ground faults. To simplify the installation, the L-Series uses a universal mounting plate allowing you to mount the devices to a wide array of backboxes. With an on-board shorting spring, Installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to suit a wide range of application requirements using the following: • Field-selectable candela settings. • Automatic selection of 12- or 24-volt operation. • Rotary switch for horn tones with two volume selections. L-Series Specifications Architect/Engineer Specifications General The L-Series ceiling-mount strobes and horn strobes shall mount to any of the following: • double-gang backbox • 4-inch octagon backbox • a standard 4 x 4 x 1 1/2-inch backbox Two-wire products shall also mount to a single-gang com- pact 2 x 4 x 17/8-inch backbox. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, the L-Series products, when used with the Sync•Cir- cuit Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When it is used with the Sync•Cir- cuit Module, the following occur: • 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. • 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. The Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Features • Listed for ceiling mounting only. • Features a plug-in design so that there is minimal intrusion into the backbox. • Designed with a tamper-resistant construction. • Provides an automatic selection of 12- or 24-volt operation at 15 and 30 candela. • Uses field-selectable candela settings on the following ceiling units: - 15 - 30 - 75 - 95 - 115 - 150 - 177 • Produces horn rated at 88+ dBA at 16 volts. • Offers a rotary switch for horn tone and two volume selections. • Includes a universal mounting plate for ceiling units. • Contains a mounting plate with a shorting spring feature that checks the wiring continuity before device installa- tion. • Compatible with System Sensor synchronization protocol. • Supports electrical compatibility with the legacy SpectrAlert and the SpectrAlert Advance devices. Ceiling Horn Strobes GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 page 2 of 4 www.gamewell-fci.com 9021-60928 Rev. A UL Current Draw Table 1 lists the UL maximum strobe current draw. L-Series Specifications (Continued) Architect/Engineer Specifications (Continued) General (Continued) Ceiling strobes and horn strobes shall have the following field-selectable candela settings including: •15 •30 •75 •95 •115 •150 •177 Strobe The strobe shall be an L-Series Model _______ listed to UL Standard 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appli- ances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be an L-Series Model _______ listed to UL Standard 1971 and UL Standard 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a Sync•Circuit model MDL3 listed to UL Standard 464 and shall be approved for fire protective service. The module shall synchronize the L-Series strobes at 1 Hz and synchronize horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single-pair of wires. The module shall mount to a 4 11/6 x 4 11/16 x 2 1/8-inch backbox. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy-chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical Specifications Standard Operating Temperature:32°F to 120°F (0°C to 49°C) Humidity Range:10 to 93% non-condensing Strobe Flash Rate:1 flash per second Nominal Voltage:Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2:8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3):8.5 to 17.5V(12 V nominal) or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge:12 to 18 AWG Ceiling-Mount Dimensions (including lens):6.8" diameter × 2.5" high (173 mm diameter × 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCR, SBBCW):6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. Candela 8-17.5 Volts 16-33 Volts FWRDC DC 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 Table 1: UL Maximum Strobe Current Draw (mA RMS) GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60928 Rev. A page 3 of 4 UL Current Draw Data Table 2 lists the maximum UL Current Draw (mA RMS) allowed for 2-Wire Horn Strobes. Horn Strobe Tones and Sound Output Data Table 3 lists the horn strobe tones and sound output date. Candela 8 VDC 16 VDC 15 30 15 30 75 95 115 150 177 EM Temp Hi 103 167 71 90 143 165 187 217 254 EM Temp Low 96 165 54 71 137 161 185 211 249 EM Cont Hi 106 173 71 90 141 165 187 230 273 EM Cont Low 95 166 54 71 124 161 170 216 258 3.1K Temp Hi 111 164 69 94 147 163 184 229 257 3.1K Temp Low 103 163 54 88 143 155 185 212 252 3.1K Cont Hi 111 172 69 94 144 164 202 220 271 3.1K Cont Low 103 169 54 88 131 155 187 217 259 16V FWR Candela 15 30 75 95 115 150 177 EM Temp Hi 107 135 179 198 223 254 286 EM Temp Low 78 101 151 172 199 229 262 EM Cont Hi 107 135 179 198 223 254 286 EM Cont Low 78 101 151 172 199 229 262 3.1K Temp Hi 108 135 179 200 225 255 289 3.1K Temp Low 79 101 150 171 196 229 260 3.1K Cont Hi 108 135 179 200 225 255 289 3.1K Cont Low 79 101 150 171 196 229 260 Table 2 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts FWR DC DC 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 Table 3: Horn Strobe Tones and Sound Output Data GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 page 4 of 4 www.gamewell-fci.com 9021-60928 Rev. A SL Series Dimensions Figure 1 illustrates the dimensions for the ceiling-mount horn strobes. Figure 1 Ceiling-Mount Horn Strobes SL Series Dimensions Figure 2 illustrates the dimensions for the ceiling backbox surface mount backbox. Figure 2 Ceiling Backbox Surface-Mount Backbox L-Series Ordering Information Ceiling Horn Strobes Part Number Description PC2RL 2-Wire, Standard Horn Strobe, Red PC2WL 2-Wire, Standard Horn Strobe, White Ceiling Strobes SCRL Standard Strobe, Red SCWL Standard Strobe, White SCWL-CLR-ALERTStandard Strobe, White, ALERT Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2010 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9021-60521 Rev. B page 1 of 2 HPFF8 NAC Expander/Power SupplyDescription The Gamewell-FCI, HPFF8 is a Notification Appliance Cir- cuit (NAC) expansion panel designed to extend the power capabilities of existing NACs and provide power for the auxiliary devices. The HPFF8 connects to any 12 or 24V Fire Alarm Control Panel (FACP) or stand alone. The HPFF8 is available in 8.0 amps. It provides regulated and filtered 24VDC power to each of the four NACs and an auxiliary output. The NAC outputs are rated at 3.0 amps each (the total output cannot exceed 8.0 amps). The auxil- iary output is rated at 2.0 amps. This output is continuously supplied, even in alarm, and therefore must be taken into account for power supply loading and battery size calcula- tions. The NAC outputs may be configured as any of the follow- ing: • Four Class B (Style Y) • Two Class A (Style Z) • Two Class B and one Class A • Four Class A with the optional HPP31076 Class A adapter installed These power supplies contain an internal Battery charger capable of charging up to 26.0 amp-hour (AH) batteries. The HPFF8 is mounted in lockable wall cabinet units that can accommodate up to two (2), 18AH batteries. A multi- pack option allows for up to four chassis mount units installed in a single lockable SBB-D4 enclosure. These chassis mount units have a "CM" suffix, HPFF8CM and can accommodate two 12AH batteries. Power supplies are available in either 120VAC/60 Hz or 240VAC/50 Hz. One of the most challenging aspects of a retrofit applica- tion is locating the existing End-of-Line (EOL) resistor. In these applications that have EOL values, other than the 3.9k normally used with the HPFF8, a single resistor matching the existing EOL can be used as a reference for all the outputs. This feature speeds the installation and the system checkout, because the actual EOL does not need to be located and changed in the circuit. The reference resistor must be within the range of 1.9k to 25k. Features • Four (4) supervised notification application circuits (NACs) capable of supplying +24VDC at 3.0 amp maximum each • NAC output circuits may be configured as any of the following: - Four Class B (Style Y) - Two Class B & one Class A - Two Class A (Style Z) - Four Class A with the optional HPP31076 Class A adapter installed • Four field-programmable operational modes • 2.0 amp auxiliary continuously supplied output • Two (2) fully supervised input/output control circuits • Temporal coding and sync protocols compatible with the following notification appliance brands: - System Sensor - Faraday - Gamewell - Amseco - Cooper-Wheelock - Gentex • Supervised AC input, battery voltage, auxiliary output, charger, and earth ground faults • Trouble indication for supervision of the following: - NAC circuits - Auxiliary output - AC input - Charger - Battery voltage - Open contacts in the initiat- ing device signal inputs (for FACP trouble notification) - Earth ground faults by individual status LED's • Separate Trouble and AC Fail Form-C relay Contacts HPFF8 An ISO 9001-2000 Company 7315-1637:0102 SIGNALING S24562 FM APPROVED GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60521 Rev. B page 2 of 2 www.gamewell-fci.com Features (Continued) • The Trouble Form-C relay contacts selectable for imme- diate or a 2 hour delay with AC failure • 26 AH battery charger capability; the wall cabinet supports two 12V 18AH batteries, while the multi-pack equipment cabinets supports two 12V 12AH batteries. • NAC Overload protection and indication • Up to four chassis mount units (HPFF8CM) can be installed in the SBB-D4 backbox • Wall mount units can be configured to internally house the following: - one AOM-2SF single control module - one AOM-2R single relay module Specifications Primary Input Power:120VAC/60Hz, 3.6A or 220VAC/50Hz, 1.5A Secondary Power:24 volt operation: two (2), 7-24 AH batteries Battery Charging Capacity:Up to 26 AH batteries mounted Battery Space: HPFF8 Cabinet:Up to two 18AH batteries SBB-D4 Cabinet:Up to two 12AH batteries per supply Total Output Power:8.0A max Standby Current: 0.030 A Auxiliary Power Output:0.15A under all conditions 2.0A if load is removed dur- ing operation (external relay or AC Fail Relay is required) Specifications (Continued) NAC Output Ratings:24VDC fully regulated, 3.0A max per circuit (8.0A total) End-of-Line Resistor Range: 2K to 25k ohm, ½ watt Common Trouble Relay/AC Fail Relay:2.0A at 28VDC or 120VAC Input Control Circuit:16-30VDC @ 5mA min. Temperature Rating:32°F to 120°F (0°C to 49°C Relative Humidity:10% to 93% non-condensing Cabinet Dimensions: HPFF8 Cabinet:16.65” W x 19.0” H x 5.2” D (42.29 W x 48.26 H 13.23 D cm) SBB-D4 Cabinet:24” W x 45.9” H x 5.15” D (60.96 W x 116.52 H x 13.1D cm) Ordering Information Part Number Description HPFF8 8A fire rated power supply operating at 120VAC/60 Hz. Unit includes red enclosure with HPP lock and key HPFF8CM 8A fire rated power supply - chassis mounted operating at 120VAC/60 Hz. Unit includes mounting hardware for installation in the SBB-D4 enclosure HPFF8E 8A fire rated power supply operating at 240VAC/50 Hz HPFF8CME 8A fire rated power supply chassis mounted operating at 240VAC/50 Hz HPP31076 Class A (Style Z) NAC module FCI-VDR-D4 Vented door, PK-625 lock and key for SBB-D4 backbox, black SBB-D4 Backbox, accepts up to 4 chassis, black Standby 0.075 A Alarm 5.381 A Qty Draw Non-Alarm Qty Draw Alarm 1 x 0.07500 0.07500 1 x 0.20600 0.20600 3 x 0.00000 0.00000 3 x 0.09100 0.27300 4 x 0.00000 0.00000 4 x 0.09100 0.36400 1 x 0.00000 0.00000 1 x 0.11600 0.11600 3 x 0.00000 0.00000 3 x 0.06600 0.19800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.95100 8 x 0.00000 0.00000 8 x 0.17600 1.40800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 1.40800 8 x 0.00000 0.00000 8 x 0.17600 1.40800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 1.40800 8 x 0.00000 0.00000 8 x 0.17600 1.40800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 1.40800 0 x 0.00000 0 x 0.03000 0 x 0.03700 0 x 0.00850 0 x 0.00400 0 x 0.00650 0 x 0.05000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #3 Totals (Max 3 Amps): 4. Typical Existing P2W15 PC2W15 PC2W30 NAC #2 Totals (Max 3 Amps): Device P2W75 5.381 System Current Draw - HPFF8 Tie to Existing Total Current SW15 Secondary Alarm CurrentSecondary Non-Alarm Current 1. System Modules 1. HS-1 HPFF8 Main Circuit Board Other compatible devices Other compatible devices Total Non-Alarm Load: 2. Typical Existing NAC #1 Totals (Max 3 Amps): NAC #4 Totals (Max 3 Amps): 3. Typical Existing P2W75 TB4 Totals (Max 2 Amps): P2W75 Other compatible devices 7. Compatible Devices not listed 0.075 6. Auxiliary Power PR-3 FIRERAY5000 EVM E3SMRCO/E3SA Auxiliary Device Total Alarm Load: Protected Premises:Date:8/23/2017 Address: City:State:ID Zip:83460 Prepared By:Phone:801.468.8300 Address:Email: City:State:UT Zip:84115 Secondary Load Requirements 2.70 Amp Hours Total (AH) 1.80 0.45 2.25 x 1.2 2.70 AH 8 Amp Hours TRUE Current Draw Secondary Standby Load Select batteries from the list below. Battery Selection 8.0 AH BAT-1270 Battery (12 volt) Derating factor Secondary Load Requirements Total Secondary Load Secondary Alarm Load x5.381 A Required Alarm Time (hours) 0.084 hours Time (hours) Required Standby Time 24 hoursx Total Secondary Load from the calculation table below. 0.075 A 1481 S Major Street Office@nelsonfire.com Salt Lake City Secondary Power Requirements Hart Building BYU-Idaho 311 South 1st Street Rexburg Nelson Fire Systems HPFF8 Power Supply Page 2 of 131 Battery Distribution Chart Comments 5.30 2.16 0.54 3. The selected batteries (8AH) are within the charger range of this power supply (7-26AH). Spare Battery Capacity Secondary Standby Load 2. Selected battery size meets secondary load requirements. Battery Selection (AH) - Secondary Load Requirements (AH) Secondary Standby Load (AH) * Derating Factor 1. Batteries will fit in the FACP cabinet. Secondary Alarm Load (AH) * Derating FactorSecondary Alarm Load Shows amp-hour distribution of your selections. Spare Battery Capacity 66% Secondary Standby Load 27% Secondary Alarm Load 7% Spare Battery Capacity Secondary Standby Load Secondary Alarm Load Page 3 of 131 Honeywell Online Tools For Fire Version 2.0.11 PROJECT DETAILS Project Name : Hart Building Wellness Center - BYU-Idaho Project Code : Project Location : 311 South 1st Street, Rexburg, Idaho, 83460 PREPARED BY Nelson Fire Systems Voltage Drop Calculations POWER SOURCE : FF8 Existing  MODEL NUMBER : HPFF8 BRAND : HPP CLASS A   20.4 VOLTS   DC POWER CIRCUIT: HS-1   3 Amps   14 AWG   11 DEVICES   18.93 % (0.568) AMPS USED 4.52 % (0.922) VOLTAGE DROP POWER SOURCE : FF8 Existing  MODEL NUMBER : HPFF8 BRAND : HPP CLASS A 20.4 VOLTS DC POWER CIRCUIT: Typical Existing 1 3 Amps 14 AWG 10 DEVICES 37.33 % (1.120) AMPS USED 13.14 % (2.680) VOLTAGE DROP #MODEL CANDELA PATTERN VOLUME TONE CURRENT (amps) DISTANCE FROM PREVIOUS DEVICE (Ft) 12 AWG 14 AWG 16 AWG 18 AWG 1 P2WL 75 Temporal Low 3100Hz 0.112 50 18.710 17.720 16.133 13.615 2 P2WL 75 Temporal Low 3100Hz 0.112 50 18.733 17.756 16.190 13.705 3 P2WL 75 Temporal Low 3100Hz 0.112 50 18.778 17.827 16.304 13.886 4 P2WL 75 Temporal Low 3100Hz 0.112 50 18.846 17.934 16.475 14.157 5 P2WL 75 Temporal Low 3100Hz 0.112 50 18.936 18.077 16.703 14.519 6 P2WL 75 Temporal Low 3100Hz 0.112 50 19.049 18.256 16.987 14.971 #MODEL CANDELA PATTERN VOLUME TONE CURRENT (amps) DISTANCE FROM PREVIOUS DEVICE (Ft) 12 AWG 14 AWG 16 AWG 18 AWG 1 PC2WL 15 Temporal Low 3100Hz 0.054 165 19.818 19.478 18.932 18.064 2 P2WL 15 Temporal Low 3100Hz 0.045 40 19.827 19.492 18.954 18.099 3 P2WL 15 Temporal Low 3100Hz 0.045 55 19.849 19.527 19.009 18.187 4 SWL 15 0.043 20 19.861 19.545 19.038 18.234 5 PC2WL 15 Temporal Low 3100Hz 0.054 20 19.876 19.569 19.076 18.294 6 PC2WL 15 Temporal Low 3100Hz 0.054 25 19.900 19.607 19.137 18.391 7 P2WL 15 Temporal Low 3100Hz 0.045 30 19.936 19.663 19.227 18.534 8 SWL 15 0.043 25 19.970 19.717 19.313 18.671 9 SWL 15 0.043 20 20.001 19.766 19.391 18.795 10 PC2WL 15 Temporal Low 3100Hz 0.054 25 20.044 19.834 19.499 18.967 11 PC2WL 30 Temporal Low 3100Hz 0.088 25 20.092 19.911 19.621 19.161 Voltage Drop 0.582 0.922 1.468 2.336 Page: 1 08/24/2017 11:34:39 AM POWER SOURCE : FF8 Existing  MODEL NUMBER : HPFF8   BRAND : HPP   CLASS A   20.4 VOLTS   DC POWER CIRCUIT: Typic al Existing 2   3 Amps   14 AWG   10 DEVICES   37.33 % (1.120) AMPS USED   13.14 % (2.680) VOLTAGE DROP POWER SOURCE : FF8 Existing  MODEL NUMBER : HPFF8   BRAND : HPP   CLASS A   20.4 VOLTS   DC POWER CIRCUIT: Typic al Existing 3   3 Amps   14 AWG   10 DEVICES   37.33 % (1.120) AMPS USED   13.14 % (2.680) VOLTAGE DROP #MODEL CANDELA PATTERN VOLUME TONE CURRENT (amps) DISTANCE FROM PREVIOUS DEVICE (Ft) 12 AWG 14 AWG 16 AWG 18 AWG 1 P2WL 75 Temporal Low 3100Hz 0.112 50 18.710 17.720 16.133 13.615 2 P2WL 75 Temporal Low 3100Hz 0.112 50 18.733 17.756 16.190 13.705 3 P2WL 75 Temporal Low 3100Hz 0.112 50 18.778 17.827 16.304 13.886 4 P2WL 75 Temporal Low 3100Hz 0.112 50 18.846 17.934 16.475 14.157 5 P2WL 75 Temporal Low 3100Hz 0.112 50 18.936 18.077 16.703 14.519 6 P2WL 75 Temporal Low 3100Hz 0.112 50 19.049 18.256 16.987 14.971 7 P2WL 75 Temporal Low 3100Hz 0.112 50 19.184 18.470 17.328 15.514 8 P2WL 75 Temporal Low 3100Hz 0.112 50 19.342 18.720 17.726 16.147 9 P2WL 75 Temporal Low 3100Hz 0.112 50 19.522 19.006 18.181 16.871 #MODEL CANDELA PATTERN VOLUME TONE CURRENT (amps) DISTANCE FROM PREVIOUS DEVICE (Ft) 12 AWG 14 AWG 16 AWG 18 AWG 1 P2WL 75 Temporal Low 3100Hz 0.112 50 18.710 17.720 16.133 13.615 2 P2WL 75 Temporal Low 3100Hz 0.112 50 18.733 17.756 16.190 13.705 3 P2WL 75 Temporal Low 3100Hz 0.112 50 18.778 17.827 16.304 13.886 4 P2WL 75 Temporal Low 3100Hz 0.112 50 18.846 17.934 16.475 14.157 5 P2WL 75 Temporal Low 3100Hz 0.112 50 18.936 18.077 16.703 14.519 6 P2WL 75 Temporal Low 3100Hz 0.112 50 19.049 18.256 16.987 14.971 7 P2WL 75 Temporal Low 3100Hz 0.112 50 19.184 18.470 17.328 15.514 8 P2WL 75 Temporal Low 3100Hz 0.112 50 19.342 18.720 17.726 16.147 9 P2WL 75 Temporal Low 3100Hz 0.112 50 19.522 19.006 18.181 16.871 10 P2WL 75 Temporal Low 3100Hz 0.112 50 19.725 19.328 18.693 17.685 Voltage Drop 1.690 2.680 4.267 6.785 7 P2WL 75 Temporal Low 3100Hz 0.112 50 19.184 18.470 17.328 15.514 8 P2WL 75 Temporal Low 3100Hz 0.112 50 19.342 18.720 17.726 16.147 9 P2WL 75 Temporal Low 3100Hz 0.112 50 19.522 19.006 18.181 16.871 10 P2WL 75 Temporal Low 3100Hz 0.112 50 19.725 19.328 18.693 17.685 Voltage Drop 1.690 2.680 4.267 6.785 #MODEL CANDELA PATTERN VOLUME TONE CURRENT (amps) DISTANCE FROM PREVIOUS DEVICE (Ft) 12 AWG 14 AWG 16 AWG 18 AWG Page: 2 08/24/2017 11:34:39 AM 10 P2WL 75 Temporal Low 3100Hz 0.112 50 19.725 19.328 18.693 17.685 Voltage Drop 1.690 2.680 4.267 6.785 #MODEL CANDELA PATTERN VOLUME TONE CURRENT (amps) DISTANCE FROM PREVIOUS DEVICE (Ft) 12 AWG 14 AWG 16 AWG 18 AWG Page: 3 08/24/2017 11:34:39 AM