HomeMy WebLinkAboutMULT DOCS - 11-00330 & 11-00331 - Site Plan &Blue Water Days, Bldg #1 - 21 PlexC I TY OF
REXBURG
.
Atnericai Familp Community
Design Review Committee Meeting
#1100330 — Blue Water Days Apts.
April 3, 2012 —12:45 pm
Attendees
Design Review Committee: Thaine Robinson and Rod Jones
(Bruce Sutherland not able to attend)
Applicant: Jared Sommer, Dean Green
Staff: Natalie Powell, Amanda Saurey, Elaine McFerrin, Community Development Intern Craig Fisher
The Design Review Committee meets if there is a development issue that deviates from the design
standards stated in the City of Rexburg Development Code #1026. This meeting gives the opportunity to
examine the issues. The committee is made up of a P&Z Commissioner, a City Council member, and a
professional from the community. Council Member Bruce Sutherland was ill and not able to attend this
meeting.
The issue of today's meeting is addressing the rear elevation of the northernmost Blue Water Days building.
The rear elevation is visible as one travels on South 4'h West (Eyes to the Street"). This building needs to have
its rear elevations broken up, in order to meet the design standards requirements.
The building has the canal on two sides and is near the railroad tracks.
There was discussion on the possible use of shutters and landscaping to break up the rear elevation.
The 2 Design Review Committee members present and the applicant agreed that on the rear elevation of the
northernmost building, shutters will be added to windows on the 2 sides with horizontal siding (six windows
on each side). Three or more evergreens with a nine foot height minimum will be added along this elevation.
The plans were redlined by Dean Green to reflect these decisions.
A Council member will review the redlined plans, in order that there is consensus of the three Design Review
Committee members on these conclusions. (On April 4, 2012, Council Members Donna Benfield and Sally
Smith reviewed the redlined plans and agreed with the decisions made at the Design review meeting.)
I I -33 I/3z�33
ENGINEERING SYSTEM SOLUTIONS
4943 NORTH 29TH EAST, STE A
IDAHO FALLS, ID 83401
PHONE: (208) 552-9B74
FAX: (208) 552-9302
STRUCTURAL SUPPLEMENTAL INSTRUCTION
Date: September 26, 2012
Supplemental Instruction No.: 1
Project: Temple view Apartments / Blue Water Days
Project Number: STR12.1038
meet
Per note F under walls on the framing plan notes, All locations where the
double top plate is broken or is not continuous shall have a MS' strap
installed. This occurs at all locations where the individual wall panels
adjoin. The studs at the adjoining wall panels shall also be stitched nailed
-together with 16d nails at 16" o.c.
11 00331 & 1100332
Blue Water Days — 21 Plex
03/30/2012
OY pBXBUgC
h4 i9
U O
Routing: 21 Plex Building Plans
Done NA
❑ Jon Berry (Please review by Monday, April 9)
Please complete the following:
Do NA
❑ Review Plans
❑ L7 Red Line Notes? (Transfer notes to both job site copy & office copy)
❑ Enter Notes for the applicant under Submittals
❑ Update status in the Approvals tab
L� ❑ Return building plans and this completed checklist to Amanda Saurey
Notes:
PROJECT:
BLUE WATER DAYS APARTMENTS
REXBURG, ID
PROJECT N0:
STR12.1038
CLIENT:
TEMPLE VIEW
DATE:
MARCH 23, 20.12
BLUE WATER DAYS
11 00331, 11 003323 11 00333
Blue Water Days, LLC
Office Copy
4943 NORTH 29TH EAST, STE A
IDAHO FALLS, IDAHO 83401
Phone: (208) 552-9874
Fax: (208) 552-9302
03/23/12 1 MDG
SEAL:
MARCH 23, 2012
STR12.1038 I COVER
BASIS FOR DESIGN
DESIGN CODE: 2009 IBC
DESIGN CRITERIA:
wind speed 90 MPH Exp.0
seismic category D
allowable soil bearing pressure 1500 psf
DESIGN LOADS:
SLOPED ROOT:
Project #:
5912, 03£5
Initials:
/q&
asphalt shingles o/felt
�Sheet:
I I -
5.0
5/8" plywood or OSB
2.1
prefab wood trusses
3.5
10" batt insulation (R-30)
3.0
1/2" gypboard
2.2
mech./elec./misc.
9.2
D.L =
25.0 psf
L.L.=
35 psf
FLOOR:
floor cover
8.0
1-1/8" osb
3.5
wood I -joists
3.0
1/2" gypboard
2.2
mech./elec./misc.
2.3
D.L =
19.0 psf
L.L.=
40 psf
BALCONY:
4" concrete o/1.5" steel deck
37.0
D.L.=
37.0 psf
100 psf
EXTERIOR WALLS:
stucco on wood lath
8,0
1/2" plywood or OSB
1.7
2x wood studs at 16" o.c.
1 2
1/2" gypboard
2.2
6" batt insulation (R-25)
1,8
mech./elec./misc.
1.1
16.0 psf
MATERIALS:
Project Name: (�
�laG_GtJ �11ef Ta 5- T04 4V
Project #:
5912, 03£5
Initials:
/q&
Date:
3-Z3- IZ
�Sheet:
I I -
WOOD BEAM
ALLOWRELE STRESS DESIGN -2B5 NOS
BM MARK: RHI
Span (ft): 4.5
Lu (ft): 2.0
TL def. <U 240
LL def. < U 360
CD: 1.00
K: 1.0
LL Red. (YIN)?: N
# Supported Floors: 1
LL
Comments
DL
LL
TL
M (Ib -ft): 1074
<------------Loatls--------->I
0
from left end: 0.0
A 8
<-Reactions (lbs) --->1
G
DL(Psf)
LL(psf)
Red.LL hit, (ft)
(ps0
WTL(IN)
wu.(PI)
Left Right
roof
25.0
35.0
- 13.0
780
455
731 731
roof/Ilr
0
0
-- 0
0
0
1024 1024
floor
0
0
- 0
0
0
1755 1755
walVmisc.
0
0
-- 0
0
0
W UNIFORM LOAD(Plf):
760
455
LL
Comments
DL
LL
TL
M (Ib -ft): 1074
Project Name: Project #: Initials: Date: Sheet:
P PT LOAD (Ibs): 0
0
from left end: 0.0
A 8
No. of MICRoI s: 2
G
A B
(2) 2x 6 (3) 2x 6
(2) 1.3/4x 5.500
(2) 2x8
N (psi) @ d:
106 70
F
(2)2x 8 (3)2x 6
fb(psi):
1093 729
937
629
A TL(in):
(2) 1.3/4x 5.500
N (psi) ® d:
89 85
A CLOD):
0.02 0.01
0.01
0.01
spaNA:
109
@(psi):
901 1044
Beam Selection (A -F): G
RHa USE: rar axe
1343
A TL(in):
0.05 0.07
0.08
A U(m):
0.02 0.03
0.03
governing spana:
1,144 TL 749 TL
692 TL
Beam Selection (A-F):A
RMT use::
tat ax e
BM MARK. RH2
<------------------LOatl3-----
>
<--Reaclions(lbs)-,J
DL(ps)
LL(psp
Red.LL trib(ft)
wn(pl)
WLL(pin
Left
Right
Span (ft): 5.5
(Pat)
Lu (ft): 2.0
roof 25.0
35.0
--- 15.0
900
525
1031
1031 DL
TL def. < U 240
roof/Or 0
0
-- 0
0
0
1444
1444 LL
LL def. <U 360
floor 0
0
-- 0
0
0
2475
2475 TL
CD: 1.00
wall/misc. 0
0
- 0
0
0
K: 1.0
w .NIFoa. LOAD (pl):
900
525
M (Ib -ft): 3403
LL Red. (YIN)?: N
If Supported Floors: 1
DL
LL
Comments
P AT. LOAD (lbs): 0
0
from leftend: 0.0
NO. Of MICRO s: 2
A B
F
(2)2x 10 (3)2x 8
(2) 1-3/4x 5.500
N (psi) @ d:
96 89
161
ft, (psi):
955 1036
2314
A TL(m):
0.06 0.08
0.20
A Ulm):
0.02 0.03
0.08
spaNA:
1.128 TL 814 TL
328 TL
Beam Selection (A-F):A
R, He USE.
rat ax to
BM MARK: RH3
_..Reactions(Ibs)---->J
DL(ps)
LL (ps)
Retl.LL tdb (f)
WTL (DID
WD, (PI)
Left
Right
Span (ft): 3.5
(ps)
Lu (ft): 2.0
roof 25.0
35.0
-- 15.0
900
525
656
656 DL
TL def, < U 240
roofer 0
0
--- 0
0
0
919
919 LL
LL def. < U 360
floor 0
0
- 0
0
0
1575
1575 TL
Co: 1.00
walymisc. 0
0
- 0
0
0
K: 1.0
W UNIFORM LOAD (PI):
900
525
M (Ib -ft): 1378
LL Red. (YIN)?: N
# Supported Floors: 1
DL
LL
Comments
Project Name: Project #: Initials: Date: Sheet:
P PT. LOAD (lbs): 0 0 from left end: 0.0
No. of MICRor ms: 2
A 8
F
G
(2) 2x 6 (3) 2x 6
(2) 1.3/4x 5.500
(2) 2x8
N (psi) @ d:
106 70
91
71
fb(psi):
1093 729
937
629
A TL(in):
0.05 0.03
0.03
0.02
A CLOD):
0.02 0.01
0.01
0.01
spaNA:
920 TL 1,380 TL
1,274 TIL
2,107 TL
Beam Selection (A -F): G
RHa USE: rar axe
Project Name: Project #: Initials: Date: Sheet:
WOOD BEAM
eM MARK: RB1
Span (ft): 9.0
Lu (ft): 2.0
TL def. <L/ 240
LL def. <L/ 360
Co: 1.00
K: 1.0
LL Red. (YIN)?: N
# Supported Floors: 1
—Reactions (lbs) -->l
Left
Right
ALLOWABLE STRESS DESIGN - 2005 NDS
675 DL
945
945 LL
1620
1620 TL
(2) 2x 12 (3) 2x 10
(2) 1-3/4x 7.250
DL (psf)
LL (psf)
Red.LL trib (ft)
wn (plf)
W L (plf)
to (psi):
691 682
1427
(psf)
A TL(in):
0.09 0.11
roof
25.0
35.0
-- 6.0
360
210
roof/flr
0
0
-- 0
0
0
floor
a
0
-- 0
0
0
wall/misc.
0
0
— 0
0
0
w oxnoaN w>o(plf):
360
210
DL
LL
Comments
—Reactions (lbs) -->l
Left
Right
675
675 DL
945
945 LL
1620
1620 TL
M (Ib -ft): 3645
Project Name: Project #: Initials: Date: Sheet:
P Pr. Low (lbs): 0 0 from left end: 0.0
N0. of MIcROLAMS: 2
A B
F
G
(2) 2x 12 (3) 2x 10
(2) 1-3/4x 7.250
(2) 1-3/4 x 9.5
fv(psi) (fid:
57 48
83
60
to (psi):
691 682
1427
831
A TL(in):
0.09 0.11
0.25
0.11
A DL(in):
0.04 0.05
0.10
0.05
governing span/A:
1,157 TL 965 TL
429 T
966 TL
Beam Selection (A-F):G
R91 us E111.3/4%9.5
Project Name: Project #: Initials: Date: Sheet:
STEEL BEAM
Boll Capacity
Default beam dept''": 12 In
Supported beam dept pn): 0 (B" if to same)
Quantity:
Web and shear plata
SWHYSUAMRT AUOWRBLESME530ESIONAISCI9
1.00 in
the
1.00 in
Web Steel Fo:
BEAM MARK: R82
Shear Plate thickness:
3/8 in
(s)ing!e/(d)oub!e shear plate?:
reduced
Web Shear Capacity:
21.3k CSR=0.16 OK
Shear Plate Capacity:
Reactions (k)
25
Span (ft): 22.0
load
DL (2s0
I.I. (psf)
LL (ps0
Iib (ft)
w (pIQ w (plf)
Left Right
0 0
TL collection <U 240
roof
25
35
35
5
300
175
1.55 1.55
DL
LL defec8on<U We
floor
0
0
0
0
0
0
1.93 1.93
LL
Lb Off: 2.0
m/sc.
0
0
-
0
0
0
3.48 3.48
TL
Lp(ft): 2.73
selff.
16
-
-
-
16
0
Wile
177.9 kip.ft
L,(ft 8.04
902k
DLL:--- OK
fb-
w(un!form load):
316
175
I,ee>
521n'
Lr Red (YIN): n
DL
LL
#VALUEI
#VALUEI Unity=
Comments
DR: 0.0 in
6maf: 103.0 in'
P CONCENTRATED LOAD(x)t
0.00
0.00
from left end:
0.00
1.00 in
Fb=
On: 0473
OK
Fy=50 ksi M=
19.1 kip -ft
MdPb=
50.2 kip -ft
VdQb=
62A
DLL: U855
OK
to
13.42 ksi
Fe=
35.21 ksi
V=
3.5 k
DOL: 0.2 in
Diameter'
314 in
1.00 in
Unity=
0.38
OK
Unity=
0.07
OK
OTC 0.8 in
Web Shear Capacity:
Boll Capacity
Default beam dept''": 12 In
Supported beam dept pn): 0 (B" if to same)
Quantity:
Web and shear plata
V
1.00 in
the
1.00 in
Web Steel Fo:
65 ksi
Shear Plate thickness:
3/8 in
(s)ing!e/(d)oub!e shear plate?:
S
Web Shear Capacity:
21.3k CSR=0.16 OK
Shear Plate Capacity:
32.4k CSR=0.11 OK
Boll Capacity
Default beam dept''": 12 In
Supported beam dept pn): 0 (B" if to same)
Quantity:
3
Diameter,
3/41n
Grade:
A325 -N Weld
1/4 In
Bolt Shear Capacity:
31.8k
CSR=0.11 OK
Boll Bearing Capacity:
27.3k
CSR=0.13 OK
RB2 USE wiU16 Fy=loo ksi d=12.0 bf=4.0 A=4.7
BEAM MARK:
reduced
Reactions (k)
Span (ft): O.DD
load
DL (psp
LL(p.1
LL (psfl till (ft)
wrL (pl1) WIL (pith)
Left Right
TL deflection <U 240
roof
25
35
35 5
300 175
#DIV101 #DIVI01 DL
LL defection <U 360
floor
0
0
0 0
0 0
#DIV/01 #DIV/01 LL
Lb (it): 2.0
mist.
0
0
-- 0
0 0
#DIV/01 #DIVMI TL
Lp(it): 6.82
selfw,
50
---
_. _..
50 0
0
L,(fl)'23.77
0.00 0.00
LL
Lp(it): 2,90
w(uniform load):
350 175
I,4> #VALUEI in'
Lr Red (YIN):n
0
DL
LL
TL
Comments
lamed 394.0 In'
P CONCENTRATED LOAD (k):
0,00
0.00
from left end: 0.00
0
0
Oa: -- OK
Fy=50 ksl M=
#VALUEI
Wile
177.9 kip.ft
Will,=
902k
DLL:--- OK
fb-
#VALUEI
Fb=
33.00 ksl
V=
#DIVroI
Do,:#VALUE!
Dn: -
Unity=
#VALUEI
#VALUEI Unity=
#DIVNI #DIV/01
DR: 0.0 in
Webs ntl sheer plate
67.2k
BOI1 Capacity
DLL:--
OK
4:
1.00 in
Fb=
34.831,81
_
Default beam dept "D":
12 in
lb:
1.00 in
Supported beam depth (In):
0 (7" if the same)
Web Steel Fo:
65 ksl
OK
D,.: 0.0 in
Quantity:
3
Shear Place thickness:
318 In
Diameter'
314 in
1.00 in
(s)inglel(d)ouble shear plate?:
S
Default beam depth"D":
12
Gratle:
A325 -N Weld:
1/4 in
Web Shear Capacity:
35.8k
#DN/01
#DIV/01
Boll Shear Capacity:
31.8k
#DIVNI #DIV/0!
Shear Plate Capacity:
32.4k
#DIVNI
#DIVNI
Boll Bearing Capacity,
46.0k
#DIV/01 #DIV/01
3
--
USE
W12X50
Fy= 50 ks1
d=12.2
bf=8.1 A=14.7
BEAM MARK: xxxx
reduced
Reactions (k)
Span (fl): 0.00
load
OL (pan
LL (ps0
LL (psp t'b (ft)
w (plq
WuL (plf)
Left Right
TL defection < U 240
roof
0
0
0 0
0
0
0.00
LL defection <l/360
floor
0
0
0
0.00
OL
Lb (h): 2.0
m1w..
0
0
0
0
0
0.00 0.00
LL
Lp(it): 2,90
selfm.
19
-- 0
0
0
0,00 0.00
TL
L,(%):8,61
-
- --
w(uniform load):
19
.19
0
0
I,Be>
Oln'
Lr Red MN):n
DL
LL
Comments
lauuad 130.0
1n4
P CONCENTRATED LOAD (k):
0.00
0.00
from left end: 0.00
Dn: -
OK
FY 50 ksl M=
0.0 kip -A
Melillo=
61.8 kip -ft
VO?4=
67.2k
DLL:--
OK
fb=
0.0 ksi
Fb=
34.831,81
V=
0.0k
Da: O. in
Unity=
O.D
OK Unity=
0.00
OK
D,.: 0.0 in
Weband shear plate
Bolt Capacity
Id
1.00 in
Default beam depth"D":
12
In
In:
1.001n
Supported beam depth (in):
0
("0' if the
same)
Web Steel Fu:
65 ksl
Quantity:
3
Shear Plate thickness:
3/8 In
Diameter.
W4 In
(s)Inglel(d)ouble shear plate?:
S
Grade:
A325 -N
Weld:
1/4 In
Web Shear Capacity:
22.8k
CSR=O.00
OK
BOIL Shear Capaciy.
31.8k
CSR=0.00 OK
Shear Plate Capacity:
32.4,
CSR=0.00
OK
Bolt Easing Capacity:
29.2k
CSR=0.00 OK
xxxx
USEW12x19
Fy=60ks1
d=12.2
bf=4.0 A=5.8
Project Name: Project #: Initials: Date: Sheet:
SbN&n..a. AN crle.,4
STEEL BEAM
SIMPLYSUPPORT. AU0WABLESTRESSDESIGNAISC13,
BEAM MARK: R133
reduced
Reactions (k)
Span (ft): 29.50
load
DL (psf)
LL (psf)
I.L. (psf) trib (ft)
wn, (pg)
wLL (plf)
Left Right
TL defection< U 240
roof
25
35
35 5
300
175
2.23 2.23 DL
I.I. deflection < U 360
floor
0
0
0 0
0
0
2.58 2.58 LL
Lb (ft): 2.0
misc.
0
0
- 0
0
0
4.81 4.81 TL
Lp(ft): 4.80
self wt..
26
-
- -
26
0
L, (it): 14.92
w(uniform load):
328
175
Iraq' 130 in
Lr Red (YIN): n
DL
LL
Comments
tactual 394.0 in°
ladua6 144.0 in
P CONCENTRATED LOAD (k):
0.00
0.00
from left end: 0.00
On-: U240 OK
Dn: U266 OK
Fy = 50 ksi M =
35.5 kip -ft
Mn/Ob =
78.1 kip -ft
VIA =
53.7 k
DLL: 0505 ON
DLL: U496 OK
fb=
15.25 ksl
Fib =
33.59 ksi
V=
4.8 k
DOL 1.1 in
DOL: 0.61n
Unity=
Unity=
0.45
OK Unity=
0.09
OK
Dn-: 1.3 in
Web and shear plate
Bolt Capacity
Bolt Capacity
Iv:
lv:
1.00 in
Default beam depth V':
Default beam depth "D":
10
in
Ih
Ih:
1.00 in
Supported beam depth (In):
Supported beam depth (in):
0
("0" if the
same)
Web Steel Fu:
65 ksl
Quantity:
Quantity:
2
Shear Plate thickness:
Shear Plate thickness:
3/8 in
Diameter.
Diameter:
314 in
(s)ingle/(d)ouble shear plate?:
(s)ingle/(d)ouble shear plate?:
S
Grade:
Grade:
A325 -N
Weld:
114 in
Web Shear Capacity:
14.1k
CSR=0.34
OK
Bolt Shear Capacity:
21.2k
CSR=0.23 OK
Shear Plate Capacity:
18.1 k
CSR=0.26
OK
Boll Bearing Capacity:
30.4 k
CSR=0.16 OK
R84
RB3
USE
WIOX26
Fy= 50 ksl
d=10.4
d=10.3
bf=5.8 A=7.6
BEAM MARK: RB4
reduced
Reactions (k)
Span (ft): 41.00
load
DL (psf)
LL (pall
LL (psf) trib (ft)
wn (PI)
WLL (Pit)
Left Right
TL deflection < U 240
roof
25
35
35 5
300
175
3.96 3.96 OL
LL deflection < U 360
floor
0
0
0 0
0
0
3.59 3.59 LL
Lb R: 2.0
misc.
0
0
-- 0
0
0
7.54 7.54 TL
Lp(it): 9.15
self wt.
68
---
- --
68
0
Lr R: 40.51
w(uniform load):
368
175
Iraq> 394
Lr Red (Y/N): n
OL
I.L.
Comments
tactual 394.0 in°
P CONCENTRATED LOAD (k):
0.00
0.00
from left end: 0.00
On-: U240 OK
Fy = 50 ksi M =
77.3 kip -ft
Mnfl1b =
212.8 kip -ft
Vn/(?b =
97.8 k
DLL: 0505 ON
fb=
12.26 ksi
Fb=
33.74 ksi
V=
7.5 k
DOL 1.1 in
Unity=
0.36
OK Unity=
0.08
OK
DTL: 2.0 in
Web and shear plate
Bolt Capacity
Iv:
1.00 in
Default beam depth V':
10
in
Ih
1.00 In
Supported beam depth (In):
0
p'0" if the
same)
Web Steel Fu:
65 ksl
Quantity:
2
Shear Plate thickness:
3/8 in
Diameter.
3/4 in
(s)ingle/(d)ouble shear plate?:
S
Grade:
A325 -N
Weld:
1/4 in
Web Shear Capacity,
25.5 k
CSR=0.30
OK
Bolt Shear Capacity:
21.2 k
CSR=0.36 OK
Shear Plate Capacity
18.1 k
CSR=0.42
OK
Bolt Bearing Capacity:
39.2 k
CSR=0.19 OK
R84
USE
W10X68
Fy= 50 ksi
d=10.4
bf=10.1 A=20.0
Project Name:11 Project #: Initials: Date: Sheet:
Steel Bm wBollao8.odtoxla
Mark
Span
Apx Avg Trib
or FBD
R left
R right
Notes —/Size
a I
F1001-
l // 2)1 2-M6
3' f��lcony
Flo6
(z) 2x�
13, Ona
U�m�c6ti1l
g
�j I
I
`fi 6el-
2 (3� �owY
a,by
' ss
6, eq
z as
-D ca VI
33
y,43
1133
4,43
`
1
�� �Lr;l�, �
2, �
l0,2
2,b
G•2
II' STD: Il6 i i�"e�,�,
......_. . h r
rolectName:
WOODBEAM
ALLOWABLE STRESS DESIGN - 2005 NOS
BM MARK, FHi
Span (ft): 4.5
Lu (ft): 2.0
TL def. <U 240
LL def. < U 360
CO: 1.00
K: 1.0
LL Red. (Y/N)7: N
# Supported Floors: 1
DL (pse LL (psD Red..LL tdb (ft) MIT,(pIQ wu (ple
roof 0 0 - 0 0 0
rooftfir 0 0 -- 0 0 0
floor 25.0 40.0 - 6.0 390 240
wall/mist. 0 0 - 0 0 0
W UNIFORM LOAD (PID: 390 240
DL LL Comments
<-Reagions (lbs) ->I
Left Right
338 338 DL
540 540 LL
878 878 TL
M (Ib -ft): 987
BM MARK: FH3
Span (f ): 3.5
Lu (ft): 2B
TL def. < U 240
LL def. <U 360
CO: 1.00
K: 1.0
LL Red. (Y/N)7: N
9 Supported Floors: 1
P r. LOAD (Its): 0
0
from left end: 0.0
<---Reactions (lbs) ->J
A B
No. of MlcaoLAMs: 2
Reg.LL his (ft)
wn(pID
A e
Left Right
(2) 2x8
roof 0 0
- 0
0
F
G
(2) 2x 6 (3) 2x 6
roof/Ilr 0 0
- 0
0
0
910 910
(2)1-3/4x 5.500
(2) 2x8
fv (psi) @ d:
64 42
520
1479 1479
TL
wall/mist. 0 0
- 0
54
44
RD (psi):
783 522
W UNIFORM LOAD (PID:
845
520
671
451
4 TI -fir):
0.05 0.04
0.04
0.02
A DLII
0.02 0.01
0.02
0.01
governing spaNd:
999 TL 1.498 TL
2,288 TL
Beam Selection (A -F): G
FHl
USE:
rat zxe
BM MARK: FH2
I<--
-Loads---
> <-Reacllons
(II
DL(ps0 LL(psD
Red.LL tib(ft)
wn(PIQ
wu(pl0
Left
Right
Span (ft): 5.5
(psD
Lu (ft): 2.0
roof 0
0
- 0
0
0
821
821 DL
TL def, < U 240
roof/fir 37.0
100.0
- 3.0
411
300
1650
1650 LL
LL def. < U 360
floor 25.0
40.0
- 7.5
488
300
2471
2471 TL
Co: too
wall/misc. 0
0
- 0
0
0
K: 1.0
w UNIFORM LOAD (PID:
899
600
M(Ib-ft):
3397
LL Red. (Y/NI N
# Supported Floors: 1
DL
LL
Comments
P RT. LOAD (Ibs): 0
0
from left end:
0.0
NO. of MICROLAMS: 2
A B
F
(2) 2x 10 (3) 2x 8
(2) 1J/4x 5.500
fv (psi) @ d:
96 89
160
It, (p.1):
953 1034
2310
A TL(in):
0.06 0.08
0.20
A DL(in):
0.02 0.03
0.07
span/A:
1,891 LL 1,222 LL
49311
Beam Selection (A-F):A
PH2:
Mae.
121 ax to
BM MARK: FH3
Span (f ): 3.5
Lu (ft): 2B
TL def. < U 240
LL def. <U 360
CO: 1.00
K: 1.0
LL Red. (Y/N)7: N
9 Supported Floors: 1
DL LL
Comments
P aT. LOAD (Its): 0 0 from left end: 0.0
NO. Of MIORIX Ivv 2
<---Reactions (lbs) ->J
A B
DL(psD LL(psf)
Reg.LL his (ft)
wn(pID
wLL OR)
Left Right
(2) 2x8
roof 0 0
- 0
0
0
569 569
DL
roof/Ilr 0 0
- 0
0
0
910 910
LL
floor 25.0 40.0
- 13.0
845
520
1479 1479
TL
wall/mist. 0 0
- 0
0
0
FHB use: rat 111
11
W UNIFORM LOAD (PID:
845
520
M (Ibft): 1294
DL LL
Comments
Project Name: Project #: Initials: Date: Sheet:
P aT. LOAD (Its): 0 0 from left end: 0.0
NO. Of MIORIX Ivv 2
A B
F
G
(2) 2x 6 (3) 2x 6
(2)1-3/4x 5.500
(2) 2x8
fv (psi) @d:
99 66
85
67
fib (psi):
1027 684
880
591
A TI -Cin);
0.04 0.03
0.03
0.02
A DL(n):
0.02 0.01
0.01
0.01
spaNd:
960 TL 1,470 TL
1,35Z Il
2,244 TL
Beam Selection(A-F): G
FHB use: rat 111
11
Project Name: Project #: Initials: Date: Sheet:
WMOM BEAM
ALLOWABLE STRESS DESIGN -1005 NDS
eM MARK: FH4
e------------Loads-------%c--Re
No. Of MICROLAMs: 2
A B
OWS(lbs)-->i
G
DL(psf)
LL(psf)
Red.LL trib(fl)
WTL(00
w-L(pl0
Left
Right
fb (psi):
Span (fl): 4.5
413
277
(pal)
0.03 0.02
0.02
0.01
A DL(in):
0.01 0.01
Lu (ft): 2.0
roof 0
0
-- 0
0
0
672
672 DL
FRa 119Er (2)2x8
TL def. < U 240
roof/Br 37.0
100.0
- 3.0
411
300
1350
1350 LL
LL def. < U 360
floor 25.0
40.0
--- 7.5
488
300
2022
2022 TL
Co: 1.00
walumisc. 0
0
- 0
0
0
K: 1.0
W UNIFORM mw (plf):
899
600
M (Ib -ft):
2274
LL Red. (YIN)?: N
# Supported Floors: 1
DL
LL
Comments
P PT. LOAD (lbs): 0
0
from left end:
0.0
NO. Of MICRoIAMs:2
A B
F
G
(2) 2x 8 (3) 2x 8
(2) 1-3/4x 5.500
(2) 2x8
fv (psi) @ d:
102 68
125
102
fb (psi):
1038 692
1547
1038
A TLQn):
0.05 0.04
0.09
0.05
O DLQn):
0.02 0.01
0.03
0.02
governing span/A:
1,487 LL 2,230 LL
899 L
,487 LL
Beam Selection ( A- F ):
G
FH4
u se:
121 axe
RM MARK: FH5
c-
-------Loads------
--%<--Reactions(Ibs)->i
DL(psf)
LL(psf)
Red.LL trib(ft)
w% (DO
WLL(pit)
Left
Right
Span (ft): 4.5
(Psf)
Lu (ft): 2.0
roof 25.0
35.0
-- 4.0
240
140
225
225 DL
TL def. < U 240
roof/fir 0
0
- 0
0
0
315
315 LL
LL def. < U 360
floor 0
0
-- 0
0
0
540
540 TL
Co: 1.00
wall/mist. 0
0
-- 0
0
0
K 1.0
w uN,mm Low (plf):
240
140
M (Ib -ft):
608
LL Red. (Y/N)7: N
# Supported Floors: 1
DL
LL
Comments
Project Name: Project #: Initials: Date: Sheet:
P PT. Low (lbs): 0 0 from left end: 0.0
No. Of MICROLAMs: 2
A B
F
G
(2) 2x 6 (3) 2x 6
(2) 1-3/4x 5.500
(2) 2X8
fv (psi) @ d:
39 26
34
27
fb (psi):
482 321
413
277
A TL(in):
0.03 0.02
0.02
0.01
A DL(in):
0.01 0.01
0.01
0.01
span/A:
1,823 TL 2,434 TL
2248 L
3,717 TL
Beam Selection (A-F):G
FRa 119Er (2)2x8
Project Name: Project #: Initials: Date: Sheet:
Title :
Dsgnr.
Description
Scope:
Job #
Date: 11:04AM, 26 JAN 10
User:KW.0606177,Ver5.8.0,1o00.2003 Steel Beam Design Page 1
fc119832003 ENERCALC Encineetino 9o(lwaie Fbt ecaCalculatiore
General information
0.460
Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 r
Steel Section : HSS1OX2X114
Fy 46.00ksi
1.150
1.150 1.150
Pinned -Pinned Load Duration Factor 1.00
Center Span
8.50 ft
Sm Wt. Added to Loads Elastic Modulus 29,000.0 ksi
Left Cant.
0.00 ft
LL & ST Act Together
Right Cant
0.00 ft
Lu : Unbraced Length
4.00 ft
Distributed Loads
Summary
Notel Short Term Loads Are WIND Loads.
#1
#2
#3 #4 #5 #6 #7
DL 0.110
Using: HSS10X2X1/4 section, Span= 8.50ft, Fy = 46.Oksi
k/ft
LL 0.300
k/ft
ST
k/ft
Start Location
Actual
ft
End Location
ft
Point Loads
24.150 k -ft
Notal Short Term Loads Are WIND Loads.
Dead Load 0.460
0.460
0.460 0.460
k
Live Load 1.150
1.150
1.150 1.150
k
Short Term
k
Location 0.250
3.800
4.200 8.250
ft
Summary
Beam OK
Static Load Case Governs Stress
Using: HSS10X2X1/4 section, Span= 8.50ft, Fy = 46.Oksi
End Fixity = Pinned -Pinned, Lu = 4.00ft, LDF = 1.000
Actual
Allowable
Moment
10.779 k -ft
24.150 k -ft
Max. Deflection -0.084 in
fb : Bending Stress
12.319 ksi
27.600 ksl
Length/DL Dell 4,199.5 :1
fb / Fb
0.446 : 1
Length/(DL+LL Defl) 1,221.5 :1
Shear
5.133 k
85.744 k
fv : Shear Stress
1.101 ksi
18.400 ksi
tv I Fv
0.060 : 1
Force & Stress Summary
<<--These columns are Dead + Live Load placed as noted --»
DL
LL LL+ST
LL LL+ST
Maximum
Only
Ol Center (d) Center
Cants Cants
Max. M + 10.78 k -ft
3.13
10.78
k -ft
Max. M -
k -ft
Max. M @ Left
k -ft
Max. M @ Right
k -ft
Shear @ Left 5.13 k
1.49
5.13
k
Shear @ Right 4.94 k
1.44
4.94
k
Center Defl. -0.084 in
-0.024
-0.084 -0.084
0.000 0.000 in
Left Cant Dell 0.000 in
0.000
0.000 0.000
0.000 0.000 in
Right Cant Dell 0.000 in
0.000
0.000 0.000
0.000 0.000 in
...Query Dell @ 0.000 ft
0.000
0.000 0.000
0.000 0.000 in
Reaction @ Left 5.13
1.49
5.13 5.13
k
Reaction @ Rt 4.94
1.44
4.94 4.94
k
Fa calc'd per Eq. E2-2, K'L/r> Cc
Title :
Dsgnr:
Description
Scope:
Job #
Date: 11:O4AM, 26 JAN 10
I1ser.,KW.0606177,Ver5.0.0.1-Dec-2003 Steel Beam Design (cp9932003ENERCALC Engineering Software g Page, 2_
Description FB1
Section Properties
ecrwr�.g�+
HSS1OX2X114
-
Depth
10.000 in
Weight
17.80 #!ft
Web Thick
0.233 in
Ixx
52.500 in4
Width
2.000 in
lyy
3.670 in4
Flange Thick
0.233 in
Sxx
10.500 in3
Area
5.24 int
Syy
3.670 1n3
Rt
1.000 in
R-xx
3.170 in
Values for LRFD Design....
R-yy
0.838 in
J
12.200 in4
Zx
14.400 in3
Cw
7.99 in6
Zy
4.260 in3
STEEL BEAM
Bolt Capacity
reduced
1.001n
Reactors (k)
Span (ft): 29.50
tl
DL (P 0
LL (p fl
SMIMYaVPPoNT ALLOwABLE81RE55 CESIGNNSC Ii
wn (Plo wu (Pio
Left Right
TL collection <U 240
roof
0
0
0 0
0 0
reduced
LL defeclion< U 360
Moor
Reactions (k)
100
BEAM MARK: F82
Span (ft): 9.50
load
DL (Pao
LL (PSO
LL ipso trib (ft)
wn (Pf)
WL,(PID
Left RI9ht
0 0
TL defection < U 240
roof
0
0
0 0
0
0
1.13 1.13
DL
LL deflection < LI 360
Hoar
37
100
100 6
822
600
2.85 285
LL
Lb (ft): 2.0
misc.
0
0
-- 0
0
0
3.98 3.98
TL
Lp(ft): 2.73
selfwl.
16
-
- --
16
0
fb=
14.91 ksi
L, (11Y. 8.04
33.54 kst
V=
6.5 k
w(uniform load):
838
600
64> 11
In°
Lr Red (YIN): n
0.10 OK
DL
LL
Comments
94.5k
1W.W 103.01n'
P OONCENTRATED
LOAD (k):
O.DO
0.00
from left and: 0.00
Default beam depth V:
Dn: U2217
OK
Fy=50 ks1 M=
9.5 klp.ft
MnA1b=
50.2 kip -ft
VdOb=
52.8k
same)
Du: L13097
OK
to=
6.63 ksl
Fb=
35.21 ksi
V=
4.0 k
3/8 in
DDL: 0.0 In
Diameter.
314 In
Unity=
0.19
OK Unity=
0,08
OK
DoC, 0.1 In
A325 -IJ Weld:
Web and shear plate
Web Shear Capacity:
25.2k
Ball Capacity
OK
Bolt Shear Capacity
31.8k
CSR=0.20 OK
Iw
1.DO in
CSR=0.20
OK
Default beam depth V:
12
in
FB3
In:
1.W in
Fy=50ks1
d=12.3
Supported beam depth (in):
0
CO' if the
same)
Web Steel Fu:
65 lost
Quantity:
3
Shear Plata Nickness:
318 in
Diameter
3/41n
(s)Ingle/(d)ouble shear plata?:
S
Grace:
A325 -N
Weld:
114 in
Web Shear Capacity:
21.3k
CSR=0.19
OK
Bolt Shear Capacity:
31.8k
CSR=0.13 OK
Shear Plate Capacity:
32.4k
CSR=0.12
OK
Bolt Bearing Cspeclty.
27.3k
CSR=0.15 OK
FB2
USE
W12%16
Fy=50 ksl
d=72,0
bf=4.0 A=4.7
BEAM MARK: F83
Bolt Capacity
reduced
1.001n
Reactors (k)
Span (ft): 29.50
tl
DL (P 0
LL (p fl
LL ipso Irib (ft)
wn (Plo wu (Pio
Left Right
TL collection <U 240
roof
0
0
0 0
0 0
2.08 2.08 DL
LL defeclion< U 360
Moor
37
100
100 3
411 300
4.43 4.43 LL
Lb (ft): 2.0
misc.
0
0
-- 0
0 0
650 6.50 TL
Lp(ft): 5.37
selfwt.
30
-
-- --
30 0
0
4 (ft): 15.60
9.76 9.76 TL
Lp(1): 10.67
selfwl.
w (uniform load):
441 300
4<, ° 176 in'
Lr Red (YIN): n
65
DL
LL
Comments
lanus4 238.0 W
P CONCENTRATED LOAD (k);
0.OD
0.00
fromieftend: 0.00
300
Dn: U325 OK
Fy=50 ksi M=
48.0 kipd
Md(7b=107.9
kip -ft
Vd4b=
642k
DLL: U478 OK
fb=
14.91 ksi
Fb=
33.54 kst
V=
6.5 k
DoL: 0.31n
Unity=
0.44
OK Unity=
0.10 OK
Drt: 1.11n
Web and shear plate
Vdi)b=
94.5k
Bolt Capacity
DLL: U399 OK
Iv.
Too In
21.56 ksi
Default beam depth V:
12 In
Ih:
180 in
Supported beam depth (in):
0 ("V 8 the
same)
Web Steel Fu:
65 ksl
Quantity:
3
Shear Plate thickness:
3/8 in
Diameter.
314 In
(s)ingad(d)Ouble shear plate?:
S
Grade:
A325 -IJ Weld:
IA In
Web Shear Capacity:
25.2k
CSR=0.26
OK
Bolt Shear Capacity
31.8k
CSR=0.20 OK
Shear Plate Capacity:
32.4k
CSR=0.20
OK
Boll Bearing Capacity:
323k
CSR=0.20 OK
FB3
USE
W72%30
Fy=50ks1
d=12.3
b".5 A=8.8
BEAM MARK: FB4
Bolt Capacity
reduced
1.001n
Default beam depth "D":
12 In
Reactors (k)
Span (ft): 41.00
load
DL (po
LL ipso
LL ipso
tdb (R)
w (Pt0 -. (plf)
Left Right
TL defec8on <U 240
roof
0
0
0
0
0
0
3.61 3.61 DL
LL defection< U 360
Moor
37
100
1 D
3
411
300
6.15 6.15 LL
Lb(ft): 2.0
mist.
0
0
--
0
0
0
9.76 9.76 TL
Lp(1): 10.67
selfwl.
65
-
-
-
65
0
L1(10: 35.15
w(uniform load):
476
300
Ire,509 in,
U Red (YM): n
DL
LL
Comments
Ianuaf 533.0 In'
P CONCENTRATED LOM (k):
0.00
0.00
from left end:
0.00
Dn: U251 OK
Fy=50 ksl
M= 100.0kip-ft
MdUb=
157.9 kip -ft
Vdi)b=
94.5k
DLL: U399 OK
fb= 13.55 ksi
Fb =
21.56 ksi
V=
9.8 k
DOL: 0.71n
Unity= 0.63 OK Unity= 0.10 OK DR: 2.0 in
Web and sheer plate
Bolt Capacity
Iv:
1.001n
Default beam depth "D":
12 In
lh:
1.00 in
Supported beam depth (in):
0 (7Mte
same)
Web Steal Fu:
65 lost
Quanfty:
3
Shear Plata Nickness:
318 in
Diameter.
3/4 in
(s)ingle/(tl)ouble shear plate?:
S
Grace:
A325 -N Weld:
1/4 in
Web Shear Capacity:
37.Bk CSR=0.26 OK
Bolt Shear Capacity:
31.8k
CSR=0.31 OK
Shear Plate Capacity.
32.4k CSR=0.30 OK
Bolt Beading Capacity.
48.5k
CSR=0.20 OK
11 FB4 USE W12X56 Fy=50 ksl 11 d=12.1 bf-12.0 A=19.1
Project Name: Project #: Initials: Date: Sheet:
Sl... Wels10.
STEEL BEAM
SIMPLYSUPPORT. ALLOWABLESTRESSDESIGNAISC 13.
BEAM MARK: FBS
reduced
Reactions (k)
Span (ft): 22.00
load
DL (psf)
LL (pso
LL (psf) trib (ft)
WTL (Plf)
WLL (pit)
Left Right
TL deflection <U 240
roof
0
0
a 0
0
0
2.68 2.68 DL
LL deflection <U 360
floor
37
100
100 8
822
600
6.60 6.60 LL
Lb (ft): 2.0
mtsc.
0
0
- 0
0
0
9.28 9.28 TL
Lp(ft): 3.00
self VA
22
-
- -
22
0
Lr (ft): 9.13
w (uniform load):
844
600
Ireq' 139 Ine
Lr Red (YIN): n
DL
LL
Comments
lactual: 156.0 in
P CONCENTRATED LOAD (k):
0.00
0.00
from left end: 0.00
DTL: U268 OK
Fy= 50 ksl M=
51.1 kip -ft
MWQb =
73.4 kip -ft
Vnlf)b=
64.0 k
DLL: U378 OK
fb=
24.12 ksi
Fb=
34.68 ksi
V=
9.3 k
DDL: 0.3 in
Unity=
0.70
OK Unity=
0.15
OK
DTL: 1A in
Web and shear plate
Bolt Capacity
IY:
1.00 in
Default beam depth "D
12
In
In:
1.00 in
Supported beam depth (in):
0
("0" if the
same)
Web Steel Fa:
65 ksl
Quantity:
3
Shear Plate thickness:
3/8 in
Diameter:
3/4 In
(s)ingie/(d)ouble shear plate?:
S
Grade:
A325 -N
Weld:
1/4 In
Web Shear Capacity:
25.2 k
CSR=0.37
OK
Bolt Shear Capacity:
31.8 k
CSR=0.29 OK
Shear Plate Capacity:
32.4 k
CSR=0.29
OK
Bolt Bearing Capacity:
32.3 k
CSR=0.29 OK
FB5 USE W12X22 Fy - 50 ksl d=12.3 bf=4.0 A=6.5
Project Name: Project #: Initials: Dafe: Sheet:
Sleet Bm w Bolls.oaW. iO.ils
WOOD BEAM
1<-
_
Laeds--
-><--Reacdons Obs) ---->I
#VALUEI
#VALUE!
DL(psfi
LL(psf)
Red.LL DID (ft)
&LOWASLE STRESS DESIGN 4005 NGS
WLL(Plf)
Leff
Right
BM MARK: FBfi
1<.._
._
-LGatls----
(Psf)
#VALUEI #VALUEI #t####k
> <--Reacftbns(lbs)->I
#VALUEI
#VALUEI ##HWt#
DL(ps0
LL(psf)
ReS�L ldb(ft)
wn(PID
W.,(pif)
Left
Right
#DIV/01
Span (ft): 7.5
DL
TL def,<U 240
root/Br 25.0
100.0
- 3.0
375
300
#DN/01
Lu (ft): 2.0
roof 0
0
- 0
0
0
1219
1219 DL
#DIV/01
TL def. <U 240
roofhlr 0
0
- 0
0
0
1950
1950 LL
LL def. <U 360
Floor 25.0
40.0
- 13.0
845
520
3169
3169 TL
Co: 1.00
wal#misc, 0
0
-- 0
0
0
K: 1.0
# Supported Floors: i
W UNIFOW torso (p10:
845
520
M (Ib -ft):
5941
LL Red. (YM)7: N
# Supported Floors: 1
DL
LL
Comments
P vr. Low(Ibs): 0
0
from left end:
0.0
No. of MIOROLAMs:2
B
C
F
G
(3) 2x 12
3.1/8 x
9
(2)1-314X 7.250
(2) 1.3/4 x 11.875
fv (psi) @ d:
70
135
157
84
@(psi):
751
1690
2325
867
A TLOn):
0.07
0.18
0.28
0.08
A DLOn):
0.03
0.07
0.11
0.02
governing span/A:
1,278 TL
511 Ti
1,388 TL
Beam Selection (A -F): G
F•Ba
I1BE: 1/4X 11.B7S
BM MARK:
1<-
_
Laeds--
-><--Reacdons Obs) ---->I
#VALUEI
#VALUE!
DL(psfi
LL(psf)
Red.LL DID (ft)
WTL(Plp
WLL(Plf)
Leff
Right
#VALUEI #VALUEI ifs#
Span (ft): 0.0
#VALUEI
#DIV/01 #####
(Psf)
#VALUEI #VALUEI #t####k
i f #VALUEI
#VALUEI
#VALUEI ##HWt#
A TL(jn):
Lu (ft): 2.0
roof 0
0
- 0
0
0
#DIV/01
#DIV/01
DL
TL def,<U 240
root/Br 25.0
100.0
- 3.0
375
300
#DN/01
9DIV/01
LL
LL def.<U 360
floor 25.0
40.0
--- 7.5
488
300
#DIV/01
#DIV/01
TL
Co: 1.00
wall/misc. 0
0
--- 0
0
0
K: 1.0
WUxnoRM L.(plf):
863
600
M(Ib-ft): #VALUEI
LL Red. (YIN)?: N
# Supported Floors: i
OL
LL
Comments
BM MARK:
P FT.I.M (lbs): 0 0
from left and: 0.0
No. of MICROTAMs: 2
> <-Reactions(lbs)-->l
#VALUEI
#VALUE!
G
#WF#}7#
#N # A##F## #9I### ###M
###### ##.Ytfl7g7# ifs# #VALUEI #VALUEI
#VALUEI #VALUEI
(2) 2x8
IS (psi) @d:
#VALUEI #VALUEI ifs#
####### #VALUEI
#VALUEI
#DIV/01 #####
its (psi):
#VALUEI #VALUEI #t####k
i f #VALUEI
#VALUEI
#VALUEI ##HWt#
A TL(jn):
#VALUE! #VALUEI ###k##
####pgHf #VAWEI
#VALUEI
#VALUEI
A CLOD):
#VALUEI #VALUEI ##k#k##
#494#" #VALUEI
#VALUEI
#VALUEI
span/A:
#VALUEI #VALUEI
##E##" #VAUJEJ
#VALUE1
#VALUEI #####
0
Beam SeleL00n(A. F):A
o -- *VALUE[ ######
LL
LL def. <U 360
Floor 25.0
40.0
BM MARK:
I< --Loads-->
from left end: 0.0
No. of MICROLAMs: 2
> <-Reactions(lbs)-->l
#VALUEI
#VALUEI
DL (pall)
LL (psf)
Red.LL Nb (ft)
wn (P19
wu 010
Left
Right
#VALUE! #VALUE!
Span (ft): 0.0
#VALUEI
11DIV/01 Wr###
(Pso
#VALUEI #VALUE! 7/!####I#
N #VALUEI
#VALUE!
#VALUE! ####!#
A TL(in):
Lu (ft): 2.0
roof 0
0
- 0
0
0
#DIV/01
#DIV/01
DL
TL def. <U 240
roof/fir 0
0
-- 0
0
0
#DIV/01
#DIV/01
LL
LL def. <U 360
Floor 25.0
40.0
- 13.0
845
520
#DIV/01
#DIV/01
TL
Co: 1.00
wall#misc. 0
0
-- 0
0
0
K: 1.0
wuxlroRM Loeo(p10:
045
520
M(lb-ft): #VALUEI
LL Red. (YIN)?: N
# Supported Floors: 1
Dl_
LL
Comments
Project Name: Project #: Initials: Date: 7, Sheet:
P 'T mnD (lbs): 0 0
from left end: 0.0
No. of MICROLAMs: 2
9999f#!# 99#### #######
#VALUEI
#VALUEI
G
#FN##I##
ffpM## ###### p##yl### !f#W##
###### #VALUEI #VALUEI
#VALUE! #VALUEI
(2)2x8
fv(psi) @d:
#VALUE! #VALUE!
#VALUEI
#VALUEI
11DIV/01 Wr###
fb(psi):
#VALUEI #VALUE! 7/!####I#
N #VALUEI
#VALUE!
#VALUE! ####!#
A TL(in):
#VALUEI #VALUEI #####!#
##N####1 #VALUEI
#VALUEI
#VALUEI
A CLOD):
#VALUEI #VAWEI i177ilil##
######## #VALUEI
#VALUEI
#VALUE!
span/A:
#VALUEI #VALUEI
#VAl UPIV
#VALUEI fl##k!#
Beam Selection (A-F):G11
o uBE: rm axe
Project Name: Project #: Initials: Date: 7, Sheet:
TJI JOIST
JOIST MARK: FJ1
Span (ft): 15.0
TL def. < U 360
LL def. < U 480
Spacing (in): 16
Bearing Type(hlw): w
Web Stiffner(y/n): n
Selection No: 2
CD: 1.00
DL LL
P PT.LOAD(Ibs): 0 0
V,Ilnw (Ib): 1350
from left end: 0.0
ALL(in): 0.26 ATL(in): 0.43
G
M,IIo„(Ib-ft): 3015
3620
Reactions (Ibs)
DL Ipso LL (pso
wTL 1pm
WILL (plf)
Left Right
roof 0 0
0.0
0
250 250 DL
floor 25 40
86.7
53.333
400 400 LL
wall 0 0
0.0
--
650 650 TL
misc 0 0
0.0
0
760 760
W UNIFORM LOAD (plt):
66.7
53
M (Ib -ft): 2438
DL LL
P PT.LOAD(Ibs): 0 0
V,Ilnw (Ib): 1350
from left end: 0.0
ALL(in): 0.26 ATL(in): 0.43
G
M,IIo„(Ib-ft): 3015
3620
span/ALL: 684
span/ALL: 462
;pan/ATL: 421
FJI
WILL (Plf)
Left Right
roof 25 35
5 16 IN as
USE:
i 1.7/6
TJI
110
0.0
0
443 443
LL
JOIST MARK: RJ1
Span (ft): 19.0
TL def. < U 240
LL def. < U 360
Spacing (in): 16
Bearing Type(h/w): w
Web Stiffner(y/n): n
Selection No: 5
CD: 1.00
DL LL
P PT. LOAD(Ilbs): 0 0
V.11. (Ib): 1435
from left end: 0.0
ALL(in): 0.49 ATL(in): 0.85
M,.(lb-fl):
3620
Reactions (lbs)
span/ALL: 462
DL (pso LL Ipso
wn (0)
WILL (Plf)
Left Right
roof 25 35
80.0
47
317 317
DL
floor 0 0
0.0
0
443 443
LL
wall 0 0
0.0
--
760 760
TL
misc 0 0
0.0
0
W UNIFORM LOAD (plf):
80.0
47
M (Ib -ft): 3610
DL LL
P PT. LOAD(Ilbs): 0 0
V.11. (Ib): 1435
from left end: 0.0
ALL(in): 0.49 ATL(in): 0.85
M,.(lb-fl):
3620
span/ALL: 462
:pan/ATL: 269
11 RJ1
USE:
17.7/e
Td!
21O
Lw 16 IN Oa
Project Name: Project #: nitials: Date: Sheet:
edited Wrfi/07
• FJ1
by WeYe,bbousV 11 7/8" TJI0110 @ 16" o/c
TJ-
user.2 11/9/20094:22:55PM THIS PRODUCT MEETS ORE FIE -SET -DE -STEN
Pagel Engine Version: 6.35.0 CONTROLS FOR THE APPLICATION AND LOADS LISTED
E,_ 2❑
e 13'
Product Diagram is Conceptual.
LOADS:
Analysis is for a Joist Member.
Primary Load Group - Residential - Living Areas (psi): 40.0 Live at 100 % duration, 30.0 Dead
Vertical Loads:
Tyne Class Live Dead Location Application Comment
Point(lbs) .Roof(1.25) 600 430 8" -
SUPPORTS:
Input Bearing Vertical Reactions (lbs)
Width Length Live/Dead/UplifUTotal
1 Stud wall 3.50" 3.50" 925 / 674 / 0 / 1599
2 Stud wall 3.50" 2.25" 369 / 276 / 0 / 644
DESIGN CONTROLS:
Detail Other
End, TJI Blocking 1 Ply 11 7/8" TJI®110
End, Rim 1 Ply 1 1/4" x 117/8" 0.8E TJ -Strand Rim Board®
-Deflection Criteria: STAN DARD(LL:U360,TL:U240).
-Deflection analysis is based on composite action with single layer of 19/32" Panels (20" Span Rating) GLUED & NAILED wood decking.
-Bracing(Lu): All compression edges (top and bottom) must be braced at 3' 5" o/c unless detailed otherwise. Proper attachment and positioning of
lateral bracing is required to achieve member stability.
TJ -Pro RATING SYSTEM
-The TJ -Pro Rating System value provides additional floor performance information and is based on a GLUED & NAILED 19/32" Panels (20" Span
Rating) decking. The controlling span is supported by walls. Additional considerations for this rating include: Ceiling - None. A structural analysis of
the deck has not been performed by the program. Comparison Value: 1.36
ADDITIONAL NOTES:
-IMPORTANTI The analysis presented is output from software developed by iLevel®. iLevel® warrants the sizing of its products by this software will
be accomplished in accordance with !Level® product design criteria and code accepted design values. The specific product application, input design
loads, and stated dimensions have been provided by the software user. This output has not been reviewed by an iLevel® Associate.
-Not all products are readily available. Check with your supplier or !Level® technical representative for product availability.
-THIS ANALYSIS FOR iLevel® PRODUCTS ONLYI PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS.
-Allowable Stress Design methodology was used for Building Code IBC analyzing the iLevel® Custom product listed above.
PROJECT INFORMATION:
C o 2009 b
I
e
Level®. Federal Way. WA
OPERATOR INFORMATION:
W.0.9A�'NbeCA� ere registered tra erar s o r e
I `J6bYy§§''""77PP6M'"" dnd rS-Pxo- axe trademarks of Sle�ei®.
Maximum
Design
Control
Result
Location
Shear (lbs)
1580
1572
1950
Passed (81%)
Lt. and Span 1 under Roof loading
Vertical Reaction (lbs)
1580
1580
1719
Passed (92%)
Bearing 1 under Roof loading
Moment (Ft -Lbs)
2091
1947
3160
Passed (62%)
MID Span 1 under Floor loading
Live Load Dail (in)
0.126
0.419
Passed (U999+)
MID Span 1 under Roof loading
Total Load Dail (in)
0.219
0.629
Passed (U689)
MID Span 1 under Roof loading
TJPro
53
30
Passed
Span 1
-Deflection Criteria: STAN DARD(LL:U360,TL:U240).
-Deflection analysis is based on composite action with single layer of 19/32" Panels (20" Span Rating) GLUED & NAILED wood decking.
-Bracing(Lu): All compression edges (top and bottom) must be braced at 3' 5" o/c unless detailed otherwise. Proper attachment and positioning of
lateral bracing is required to achieve member stability.
TJ -Pro RATING SYSTEM
-The TJ -Pro Rating System value provides additional floor performance information and is based on a GLUED & NAILED 19/32" Panels (20" Span
Rating) decking. The controlling span is supported by walls. Additional considerations for this rating include: Ceiling - None. A structural analysis of
the deck has not been performed by the program. Comparison Value: 1.36
ADDITIONAL NOTES:
-IMPORTANTI The analysis presented is output from software developed by iLevel®. iLevel® warrants the sizing of its products by this software will
be accomplished in accordance with !Level® product design criteria and code accepted design values. The specific product application, input design
loads, and stated dimensions have been provided by the software user. This output has not been reviewed by an iLevel® Associate.
-Not all products are readily available. Check with your supplier or !Level® technical representative for product availability.
-THIS ANALYSIS FOR iLevel® PRODUCTS ONLYI PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS.
-Allowable Stress Design methodology was used for Building Code IBC analyzing the iLevel® Custom product listed above.
PROJECT INFORMATION:
C o 2009 b
I
e
Level®. Federal Way. WA
OPERATOR INFORMATION:
W.0.9A�'NbeCA� ere registered tra erar s o r e
I `J6bYy§§''""77PP6M'"" dnd rS-Pxo- axe trademarks of Sle�ei®.
Project#:
Initials:
Date:
Sheet:
:\Structural\2009\09218 Rezbuxg Apartments- Rexburg, ID\
gineeriog\Calculations\Gr
ity\Floor Joist.sm
by weYe'raauser
117/8" TJI@ 110 @ 16" O/C I
TJ-
user.2 11/9120094:22:55PM THIS PRODUCT MEETS OR SE 1 DESIGN
Paget Engine Version: 6.35.0 CONTROLS FOR THE APPLICATION AND LOADS LISTED
Load Group: Primary Load Group
^ 12' 7.00" ^
Max. Vertical Reaction Total (lbs) 1599 699
Max. Vertical Reaction Live (lbs) 925 369
Selected Bearing Length (in) 3.50(W) 2.25(W)
Max. Unbraced Length (in) 41
Loading on all spans, LDF = 0.90 , 1.0 Dead
Shear at Support (lbs) 663 -264
Max Shear at Support (lbs) 666 -267
Shear Within Span (lbs) 648
Member Reaction (lbs) 666 267
Support Reaction (lbs) 674 276
Moment (Ft -Lbs) 893
Loading on all spans, LDF = 1.00 ,
Shear at Support (lbs)
Max Shear at Support (lbs)
Shear Within Span (lbs)
Member Reaction (lbs)
Support Reaction (lbs)
Moment (Ft -Lbs)
Live Deflection (in)
Total Deflection (in)
1.0 Dead + 1.0 Floor
994 -595
1002 -603
959
1002 603 .
1021 622
1947
0.109
0.202
Loading on all spans, LDF = 1.25 , 1.0 Dead + 1.0 Floor + 1.0 Roof
Shear at Support (lbs)
1572 -617
Max Shear at Support (lbs)
1580 -625
Shear Within Span (lbs)
1537
Member Reaction (lbs)
1580 625
Support Reaction (lbs)
1599 699
Moment (Ft -Lbs)
2091
Live Deflection (in)
0.126
Total Deflection (in)
0.219
PROJECT INFORMATION:
OPERATOR INFORMATION:
Pj�a G.lfppalrm are reglste=ed tra emarks of=—v.7971
Project #:
Initials:
a e trademarks of flevel®.
ii Jorstural\"2009\
Dafe•
Sheet:
921Pro^
\Structural\2009\09218 Rexburg Apartments- Rexburg, ID
nglneerinq\Calculations\G
vlty\Floor .lois t.sm
��
Title :
Dsgnr: Date: 2:26PM,
Description
Scope:
User: KW.0606177. Ver6.6.0, 1-Cea2003 Steel Beam Design Page 1
!r,11863.2003 ENERCALC Engineering Software
Description Steel Stair Stringers
General Information
Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000
Steel Section : C12X20.7
Actual
Moment
Fy 36.00ksi
fb : Bending Stress
1.575 ksi
Pinned -Pinned
Load Duration Factor 1.00
Center Span
7.00 It
Bm Wt. Added to Loads
Elastic Modulus 29,000.0 ks!
Left Cant.
0.00 ft
LL & ST Act Together
14.400 ksi
Right Cant
0.00 it
Center Defl.
-0.007 in
Lu : Unbraced Length
7.00 ft
0.000 in
0.000
Distributed Loads
0.000 in
0.000
Note! Short Term Loads Are WIND Loads.
#1
42
#3 #4
#5 #6 #7 W.=
DL 0.140
Reaction @ Rt
1.61
k/ft
LL 0.300
K'L/r > Cc
k/ft
ST
k/ft
Start Location
ft
End Location
It
Using: 012X20.7 section, Span = 7.00ft, Fy = 36.Oksl
End Fixity = Pinned -Pinned, Lu = 7.00ft, LDF = 1.000
Force & Stress Sum
DL
Maximum Only
Beam OK
Static Load Case Governs Stress
Allowable
Actual
Moment
2.821 k -ft
fb : Bending Stress
1.575 ksi
lb / Fb
0.090 : 1
Shear
1.612 It
fv : Shear Stress
0.476 ksi
N / Fv
0.033 : 1
Force & Stress Sum
DL
Maximum Only
Beam OK
Static Load Case Governs Stress
Allowable
2.82 k -ft
0.98
31.417 k -ft
Max. Deflection
-0.007 in
17.535 ksl
Length/DL Dell
36,209.1: 1
Max. M @ Right
Length/(DL+LL Defl)
12,627.9: 1
48.730 k
1.61 k
0.56
14.400 ksi
1.61 k
0.56
«.- These columns are D
LL LL+ST
Center Center
2.82
Max. M +
2.82 k -ft
0.98
Max. M -
Max. M @ Left
Max. M @ Right
Shear @ Left
1.61 k
0.56
Shear @ Right
1.61 k
0.56
Center Defl.
-0.007 in
-0.002
Left Cant Defl
0.000 in
0.000
Right Cant Deo
0.000 in
0.000
...Query Defl @
0.000 ft
0.000
Reaction @ Left
1.61
0.56
Reaction @ Rt
1.61
0.56
Fa caldd per Eq. E2-2,
K'L/r > Cc
I Beam, MalorAxis, Fb per Eq. F1-8, Fb =12.000
Cb Af / (Id)
1.61
1.61
-0.007
0.000
0.000
0.000
1.61
1.61
-0.007
0.000
0.000
0.000
1.61
1.61
LL
Cants
0.000
0.000
0.000
0.000
as noted --»
LL+ST
Cants
k -ft
k -ft
k -ft
k -ft
k
k
0.000 in
0.000 In
0.000 in
0.000 in
k
k
Project Name: Project #: nitials: Date: Sheet:
Title :
Dsgnr: Date: 2:2613M.
Description
Scope:
Steel Beam Design
Stringers
Page 2
Section Properties
C12X20.7
Depth
12.000 in
Weight
20.65 #/g
Web Thick
0.282 in
Ixx
129.000 Ino
Width
2.940 in
lyy
3.860 in4
Flange Thick
0.501 in
sxx
21.500 in3
Area
6.08 int
syy
1.720 in3
Xcg Dist.
0.698 in
R-xx
4.610 in
Values for LRFD Design....
R-yy
0.797 in
J
0.369 in4
Zx
25.600 in3
Cw
112.00 ins
Zy
3.470 in3
K
1.125 in
Project Name: 11 Project #: Initials: Date: Sheet:
i
WOOD STUD WALL DESIGN
TRIMMER:
KING STUD WINO INTERIOR ZONE:
Trimmer supports only vertical load ... King stud supports only bending ...
Pcap (lbs) = 3036 Mcap (Ib -ft) = 827
bib width capacity (ft) = 6.23 for M < Mcap
trib width capacity (ft) = 3.20 for A < L / 240 (governs)
KING STUD WIND END ZONE: KING STUD EARTHPUAKE:
King stud supports only bending ... King stud supports only bending ...
Mcap (Ib -ft) = 827 Mcap (Ib -ft) = 634
Crib width capacity (0) = 5.30 for M < Mcap trib width capacity (ft) = 11.32 for M < Mcap
trib width capacity (ft) = 2.73 for A < L / 240 (governs) hih width canarih. rat = a ,
Interior Zone lst floor exterior USE: 2 X 4 @12 "O.C.
I End Zone 1st floor exterior USE: 2 X 4 @12 "O.C.
(DF No. 2)
Framing at openings Glnlae< nnmd ,ahe.,.n�.. ,....,,_ _,.
OPENING WIDTH
OFT)
Load Case
ALLOWABLE STRESS DESIGN - 2005 ND
1D+ Mend
1D+0.75L+0.75Wend+
iD+0.75L+0.525EQ+
2
1
DESCRIPTION:
Height, Is (ft) :
deflection < U:
C & C Interior Zone (psf):
C & C End Zone (psf):
earthquake pressure (pso:
LL on roof snow? (YIN):
Lumber grade:
1 st Floor exterior
8.0
240
16.6
19.5
10.0
y
2 ( DF Nn
Axial
a
0 roof
floor
wall
misc
71 NnS 9nna
DL
Loads to Wall:
LL trib
1
wLoad case
2&3 4 &5
6
7
135
180
192
111
618
25
25
20
37
35 9.0
40 12.0
0 16.0
100 5.0
w (plf)=
540
780
320
685
225 461
300 660
320 320
185 560
461
660
320
560
2325
1030 2001
2001
TRIMMER:
KING STUD WINO INTERIOR ZONE:
Trimmer supports only vertical load ... King stud supports only bending ...
Pcap (lbs) = 3036 Mcap (Ib -ft) = 827
bib width capacity (ft) = 6.23 for M < Mcap
trib width capacity (ft) = 3.20 for A < L / 240 (governs)
KING STUD WIND END ZONE: KING STUD EARTHPUAKE:
King stud supports only bending ... King stud supports only bending ...
Mcap (Ib -ft) = 827 Mcap (Ib -ft) = 634
Crib width capacity (0) = 5.30 for M < Mcap trib width capacity (ft) = 11.32 for M < Mcap
trib width capacity (ft) = 2.73 for A < L / 240 (governs) hih width canarih. rat = a ,
Interior Zone lst floor exterior USE: 2 X 4 @12 "O.C.
I End Zone 1st floor exterior USE: 2 X 4 @12 "O.C.
(DF No. 2)
Framing at openings Glnlae< nnmd ,ahe.,.n�.. ,....,,_ _,.
OPENING WIDTH
OFT)
Load Case
1D+iL+1S
1D+ Mend
1D+0.75L+0.75Wend+
iD+0.75L+0.525EQ+
2
1
1
1
0.755
0.75S
0.60 + 0.7EQ
Cd =
1.15
1.60
1.60
1.60
1.60
RE (psi) =
634
634
634
634
634
F'c (Psi) =
578
596
596
596
596
fc (psi) =
443 OK
196 OK
381 OK
381 OK
118 OK
M (Ib -ft) =
0
156
117
42
2
Fb' (psi) =
1785
3240
3240
2484
56
2484
fb (psi) =
0 OK
611 OK
458 OK
165 OK
219 OK
CSR =
0.59 OK
0.38 OK
0.76 OK
0.58 OK
0.15 OK
Oma. (in.) =
0.400
0.400
0.400
0.400
0.400
A (in.) =
0.000 OK
0.147 OK
0.157 OK
0.056 OK
0.075 OK
TRIMMER:
KING STUD WINO INTERIOR ZONE:
Trimmer supports only vertical load ... King stud supports only bending ...
Pcap (lbs) = 3036 Mcap (Ib -ft) = 827
bib width capacity (ft) = 6.23 for M < Mcap
trib width capacity (ft) = 3.20 for A < L / 240 (governs)
KING STUD WIND END ZONE: KING STUD EARTHPUAKE:
King stud supports only bending ... King stud supports only bending ...
Mcap (Ib -ft) = 827 Mcap (Ib -ft) = 634
Crib width capacity (0) = 5.30 for M < Mcap trib width capacity (ft) = 11.32 for M < Mcap
trib width capacity (ft) = 2.73 for A < L / 240 (governs) hih width canarih. rat = a ,
Interior Zone lst floor exterior USE: 2 X 4 @12 "O.C.
I End Zone 1st floor exterior USE: 2 X 4 @12 "O.C.
(DF No. 2)
Framing at openings Glnlae< nnmd ,ahe.,.n�.. ,....,,_ _,.
OPENING WIDTH
OFT)
NO. OF TRIMMERS
NO. OF KING
STUDS INT ZONE
NO. OF KING STUDS
END ZONE
NO. OF KING
STUDS EO
3
2
1
1
1
4
2
1
1
1
5
2
1
2
1
6
3
2
2
1
7
3
2
2
1
8
4
2
2
1
9
4
2
2
1
10
4
2
3
2
11
5
2
3
2
12
5
3
3
2
13
5
3
3
2
14
8
3
3
2
15
6
3
3
2
18 1
7
3
q
2
A < L / 240 (governs)
Project Name: Project #: Initials: Date: Sheet:
WDOD STUD WALL DES113N
1D+1L+iS
10+ iWend
iD+0.75L+0.75Wend+
11)+0.75L+0.525EQ+
4 @16
--
End Zone 2nd floor exterior USE:
2 X
0.75S
D E S D R I PTI D N12nd floor exterior
AL OWABLESTRES OESIG -2005 OS
Axial
0.6D+0.7EQ
Cd =
FcE (psi) =
1.15
634
1.60
Height, Is (ft) : 8.0
1.60
Loads
to
Wall:
Pc (psi) =
w Load
case
634
634
deflection <LP. 240
a
0
DL
LL
Crib
1
2&3
4 &5
6
7
C & C Interior Zone (psf): 16.6
roof25540
327 OK
98 OK
225
461
461
135
C & C End Zone (psf): 19.5
floor
25
40
6.0
390
150
330
330
90
earthquake pressure (psf): 10.0
wall
20
0
8.0
160
160
160
160
96
LL on roof snow: y
mist
37
100
3.0
411
111
336
336
67
Lumbery 2
15 4
3
3
w (plf)=
1501
646
1287
1287
388
grade: (DF
No. 2) NDS 2005
Trimmer supports only vertical load ...
King stud supports only bending
Pcap
(lbs) = 3038
KING STUD WIND ENO ZONE:
King stud supports only bending ...
Mcap (Ib -ft) = 827
URI width capacity (ft) = 5.30 for M < Mcap
trib width capacity (ft) = 2.73 for d < L / 240 (oovernsl
KING STUD EARTHGIUAKE:
King stud supports only bending ...
Mcap (Ib -ft) = 634
trib width capacity (ft) = 11.32 for M < Mcap
Irih ",id/h n ---- —
Interior Zone 2nd floor exterior USE:
1D+1L+iS
10+ iWend
iD+0.75L+0.75Wend+
11)+0.75L+0.525EQ+
4 @16
--
End Zone 2nd floor exterior USE:
2 X
0.75S
0.755
0.6D+0.7EQ
Cd =
FcE (psi) =
1.15
634
1.60
1.60
1.60
Framing at openings (unless noted otherwise on plan):
1.60
Pc (psi) =
578
ggq
596
634
634
STUDS INT ZONE
634
fc (psi) =
381 OK
164 OK
596
327 OK
596
596
M (Ib -ft) =
0
208
327 OK
98 OK
Fb' (psi) =
1785
3240
156
3240
56
2
75
� (psi)=
0 OK
815 OK
811 OK
2484
2
2484
1
OK
0.42 OK
0.69 OK
219 OK
11 3
2LOKCSR0.43
(in.) =
0.400
12 3
3
0.48 OKAm„
2
0.0.400
(in.) =
0.000 OK
0.196 OK
0.400
0.210 OK
0.400
3
0.4004
15 4
3
3
2
0.075 OK
3
0.1
2
TRIMMER:
KING STUD WINO INTERIDR :ONE:
Trimmer supports only vertical load ...
King stud supports only bending
Pcap
(lbs) = 3038
...
Mcap (Ib -fl) = 827
trib width capacity (ft) = 6.23
for M < Mcap
trib width capacity (ft) = 3.20
for d < L / 240 (governs)
KING STUD WIND ENO ZONE:
King stud supports only bending ...
Mcap (Ib -ft) = 827
URI width capacity (ft) = 5.30 for M < Mcap
trib width capacity (ft) = 2.73 for d < L / 240 (oovernsl
KING STUD EARTHGIUAKE:
King stud supports only bending ...
Mcap (Ib -ft) = 634
trib width capacity (ft) = 11.32 for M < Mcap
Irih ",id/h n ---- —
Interior Zone 2nd floor exterior USE:
_
..._ ..._ ...............r I,.I — 3.32 for
2 X
4 @16
"O.C.
End Zone 2nd floor exterior USE:
2 X
4 @16
" O.C.
(DF
No. 2)
Framing at openings (unless noted otherwise on plan):
OPENING WIDTH
(FT) NO. TRIMMERS
NO. OF KING
NO. OF KING STUDS
NO. OF KING
STUDS INT ZONE
ENDZONE
STUDS EO
8 1
1
1
1
j 5 2
2
6 2
2
2
1
7 2
2
2
1
8 2
2
2
1
93
2
2
1
10 3
2
3
2
11 3
2
3
2
12 3
3
3
2
13 4
3
3
2
14 4
3
3
2
15 4
3
3
2
16 4
3
4
2
4 < L / 240 (governs)
Project Name: i Project #: Initials: Date: Sheet:
WDOD STUD WALL DESIGN
ALLOWABLESTRESS DESIGN 2005 NDS
DEa DRIPTI ON: 3rd floor exterior Axial Loads to Wall: wLoad case
Height. Is (ft) : 8.0 a DL LL bib 1 2&3 4 &5 a 7
deflection < U: 240 0 roof 25 35 7.0 420 175 359 359 105
C& C Interior Zone (psf): 16.6 floor 0 0 0 0 0 0 0 0
C& C End Zone (psf): 19.5 wall 0 0 0 0 0 0 0 0
earthquake pressure (psf): 10.0 mist 0 0 0 0 0 0 0 0
LL on roof snow? (Y/N): y w (plf)= 420 175 359 359 105
Lumber grade: 2 (DF No. 2) NDS 2005
TRIMMER: KING STUD WiNo INTERIOR ZONE:
Trimmer supports only vertical load ...
Pcap (lbs) = 3036
KING STUD WIND END ZONE:
King stud supports only bending ...
Mcap (Ib -ft) = 827
trib width capacity (ft) = 5.30 for M < Mcap
trib width capacity (ft) = 2.73 for 0 < L / 240 (governs)
King stud supports only bending ...
Mcap (Ib -ft) = 827
trib width capacity (ft) = 6.23
bib width capacity (ft) = 3.20
for M < Mcap
for A < L / 240 (governs)
KING STUD EARTHQUAKE:
King stud supports only bending ...
Mcap (Ib -ft) = 634
trib width capacity (ft) = 11.32 for M < Mcap
TO width canacita rfrl = R q9 I p < L 1240
Interior Zone 3rd floor exterior USE: 2 X 4 @16 "O.0
Load Case
1D+iL+lS
1D+ Mend
1D+0.75L+0.75Wend+
1D+0.751-+0.525EQ+
NO. OF TRIMMERS
NO, OF KING
NO. OF KIIJG STUDS
NO. OF WNG
0.75S
0.75S
OAD+0.7EQ
Cd =
1.15
1.60
1.60
1 1.60
1.60
FcE (psi) =
634
634
634
634
1
F'c (psi) =
578
596
596
596
634
to (psi) =
107 OK
44 OK
91 OK
91 OK
596
27 OK
M (Ib -ft) =
0
208
156
56
2
Fb' (psi) =
1785
3240
3240
2484
75
2484
ib (psi) =
0 OK
815 OK
611 OK
219 OK
293 OK
CSR =
0.03 OK
0.28 OK
0.24 OK
0.13 OK
0.12 OK
Am„ (in.) =
0.400
0.400
0.400
0.400
0.400
A (in.) =
0.000 OK
0.196 OK
0.210 OK
0.075 OK
0.100 OK
TRIMMER: KING STUD WiNo INTERIOR ZONE:
Trimmer supports only vertical load ...
Pcap (lbs) = 3036
KING STUD WIND END ZONE:
King stud supports only bending ...
Mcap (Ib -ft) = 827
trib width capacity (ft) = 5.30 for M < Mcap
trib width capacity (ft) = 2.73 for 0 < L / 240 (governs)
King stud supports only bending ...
Mcap (Ib -ft) = 827
trib width capacity (ft) = 6.23
bib width capacity (ft) = 3.20
for M < Mcap
for A < L / 240 (governs)
KING STUD EARTHQUAKE:
King stud supports only bending ...
Mcap (Ib -ft) = 634
trib width capacity (ft) = 11.32 for M < Mcap
TO width canacita rfrl = R q9 I p < L 1240
Interior Zone 3rd floor exterior USE: 2 X 4 @16 "O.0
End Zone 3rd floor exterior USE: 2 X 4 @16 -O.C.
(DFNo.2)
Framing at openings (unless noted otherwise on plan):
STUDS EO
OPENING WIDTH
(FT)
NO. OF TRIMMERS
NO, OF KING
NO. OF KIIJG STUDS
NO. OF WNG
4
1
1
1
STUDS INT ZONE
5
1
i
2
1
6
1
2
2
1
7
1
2
2
1
8
1
2
2
1
9
1
2
2
1
10
1
2
3
2
11
1
2
3
2
12
1
3
3
2
13
1
3
3
2
14
i
3
3
2
15
2
3
3
2
16
2
3
4
2
11
(governs)
Project Name:
Project#: Initials: Date: Sheet:
ENDZONE
STUDS EO
3
4
1
1
1
1
5
1
i
2
1
6
1
2
2
1
7
1
2
2
1
8
1
2
2
1
9
1
2
2
1
10
1
2
3
2
11
1
2
3
2
12
1
3
3
2
13
1
3
3
2
14
i
3
3
2
15
2
3
3
2
16
2
3
4
2
(governs)
Project Name:
Project#: Initials: Date: Sheet:
WOOD STUD WALL DESIGN
TRIMMER: KING STUD WIND INTERIOR ZONE:
Trimmer supports only vertical load ... King stud supports only bending ...
Pcap (lbs) = 3036 Mcap (Ib -fl) = 827
[rib width capacity (fl) = 20.67 for M < Mcap
trib width capacity (ft) = 10.63 for d < L / 240 (governs)
KING STUD WIND END ZONE:
King stud supports only bending ...
Mcap (Ib -ft) = 827
trib width rapacity (ft) = 20.67 for M < Mcap
trib width capacity (ft) = 10.63 for A < L / 240 (governs)
KING STUD EARTHQUAKE;
King stud supports only bending ...
Mcap (Ib -ft) = 634
Crib width capacity (ft) = 11.32 for M < Mcap
URI width caoaciN (61 = ; n? I. 2
I
Interior Zone list floor interior USE: 2 X 4 @ 12 " O.C. End Zone fat floor Interior USE: 2 X 4 @12 "O.C..
(DF No. 2)
Framina at oDeninas (unless noted mh.D Il ....,
OPENINGWIDTH
(FT)
ALLOWABLE STRESS DESIGN -2005NDS
1D+iL+1S
1D+ Mend
iD+0.75L+0.75Wend+
iD+0.75L+0.525EQ+
2
DESCRIPTION: tat floor Interior
Height, Is (ft) : 8.0
deflection< U: 240
C & C Interior Zone (psf): 5.0
C & C End Zone (psf): 5.0
earthquake pressure (psf): 10.0
LL on roof snow? (YIN): y
Axial
a
0 roof
floor
wall
misc
DL
Loads to Wall:
LL trib
1
wLoad case
2&3 4 &5
6
7
195
360
96
0
651
20-4
25
10
0
5 13.0
40 24.0
0 16.0
0 0
IN (plf)=
780
1560
160
0
325 666
600 1320
160 160
0 0
666
1320
160
0
2500
1085 2146
2146
Lumber grade: 2
(DF No. 21 NDS 2nn5
Fc (psi) =
578
596
596
596
596
fc (psi) =
TRIMMER: KING STUD WIND INTERIOR ZONE:
Trimmer supports only vertical load ... King stud supports only bending ...
Pcap (lbs) = 3036 Mcap (Ib -fl) = 827
[rib width capacity (fl) = 20.67 for M < Mcap
trib width capacity (ft) = 10.63 for d < L / 240 (governs)
KING STUD WIND END ZONE:
King stud supports only bending ...
Mcap (Ib -ft) = 827
trib width rapacity (ft) = 20.67 for M < Mcap
trib width capacity (ft) = 10.63 for A < L / 240 (governs)
KING STUD EARTHQUAKE;
King stud supports only bending ...
Mcap (Ib -ft) = 634
Crib width capacity (ft) = 11.32 for M < Mcap
URI width caoaciN (61 = ; n? I. 2
I
Interior Zone list floor interior USE: 2 X 4 @ 12 " O.C. End Zone fat floor Interior USE: 2 X 4 @12 "O.C..
(DF No. 2)
Framina at oDeninas (unless noted mh.D Il ....,
OPENINGWIDTH
(FT)
Load Case
1D+iL+1S
1D+ Mend
iD+0.75L+0.75Wend+
iD+0.75L+0.525EQ+
2
1
1
1
0.755
0.75S
0.61)+0.7EQ
Cd =
1.15
1.60
1.60
1.60
1.60
FcE (psi) =
634
634
634
634
634
Fc (psi) =
578
596
596
596
596
fc (psi) =
476 OK
207 OK
409 OK
409 OK
124 OK
M (Ib -ft) =
0
40
30
42
1
Fb' (psi) =
1785
3240
3240
2484
56
2484
to (psi) =
0 OK
157 OK
118 OK
165 OK
219 OK
CSR =
0.68 OK
0.19 OK
0.57 OK
0.66 OK
0.15 OK
A... (in.) =
0.400
0.400
0.400
0.400
0.400
A (in.)=
0.000 OK
0.038 OK
0.040 OK0.056
OK
0.075 OK
TRIMMER: KING STUD WIND INTERIOR ZONE:
Trimmer supports only vertical load ... King stud supports only bending ...
Pcap (lbs) = 3036 Mcap (Ib -fl) = 827
[rib width capacity (fl) = 20.67 for M < Mcap
trib width capacity (ft) = 10.63 for d < L / 240 (governs)
KING STUD WIND END ZONE:
King stud supports only bending ...
Mcap (Ib -ft) = 827
trib width rapacity (ft) = 20.67 for M < Mcap
trib width capacity (ft) = 10.63 for A < L / 240 (governs)
KING STUD EARTHQUAKE;
King stud supports only bending ...
Mcap (Ib -ft) = 634
Crib width capacity (ft) = 11.32 for M < Mcap
URI width caoaciN (61 = ; n? I. 2
I
Interior Zone list floor interior USE: 2 X 4 @ 12 " O.C. End Zone fat floor Interior USE: 2 X 4 @12 "O.C..
(DF No. 2)
Framina at oDeninas (unless noted mh.D Il ....,
OPENINGWIDTH
(FT)
NO. OF TRIMMERS
NO. OF KING
STUDS INT ZONE
NO, OF KING STUDS
END ZONE
NO. OF KING
STUDS EQ
3
2
1
1
1
4
2
1
1
1
5
3
1
1
6
3
7
3
8
4
1
1
1
9
4
10
5
1
1
2
11
5
1
1
2
12
5
1
1
2
13
6
1
1
2
14
6
1
1
2
15
7
1
1
2
16
7
1
1
2
D < L / 40 (governs)
Project Name: Project #: nitials: Date: Sheet:
WORD STUD WALL DESIGN
TRIMMER: KING STUD WIND INTERIOR ZONE:
Trimmer supports only vertical load ... King stud supports only bending ...
Peep (lbs) = 3036 Mcap (Ib -ft) = 827
trib width rapacity (ft) = 20.67 for M < Mcap
trib width capacity (ft) = 10.63 for 0 < L/ 240 (governs)
KING STUD WIND END ZONE:
ALLOWABLE STRESS DE IGN- P005 ND
1D+1L+iS
iD+ Mend1D+0.75L+0.75Wend+
Mcap (Ib -ft) = 827
1D+0.75L+0.525EQ+
trib width capacity (ft) = 20.67 for M < Mcap
DESCRIPTION: 2nd floor Interior
7Vdal
trib width capacity lel = R n9 1.
Loads to Wall:
0.755
wLead case
Cd =
1.15
Height, IS (ft) : 8.0
a
DL
LL trib
1
2&3
4 &5
6
7
deflection < U.' 240
0 roof
25
35 13.5
810
338
692
692
203
C & C Interior Zone (psf): 5.0
floor
25
40 13.5
878
338
743
743
56
C & C End Zone (psf): 5.0
wall
10
0 8.0
3240
2484
75
2484
ib (psi) =
203
earthquake pressure (psq: 10.0
157 OK
219 OK
293 OK
80
80
80
80
48
LL on roof snow: y
misc
0
0 0
0
0
0
0
0
0.050 OK
0.054 OK
0.075 OK
w (plo=
1768
755
1514
1514
453
Lumbery graderade:2 lDF
Nn 71 NOS >nnc
18
5
1
1
i
2
2
TRIMMER: KING STUD WIND INTERIOR ZONE:
Trimmer supports only vertical load ... King stud supports only bending ...
Peep (lbs) = 3036 Mcap (Ib -ft) = 827
trib width rapacity (ft) = 20.67 for M < Mcap
trib width capacity (ft) = 10.63 for 0 < L/ 240 (governs)
KING STUD WIND END ZONE:
Load Case
1D+1L+iS
iD+ Mend1D+0.75L+0.75Wend+
Mcap (Ib -ft) = 827
1D+0.75L+0.525EQ+
trib width capacity (ft) = 20.67 for M < Mcap
trib width capacity (ft) = 11.32 for M < Mcap
trib width capacity (ft) = 10.63 for A < L 1240 (governs)
trib width capacity lel = R n9 1.
0.755
0.755
0.6D + 0.7EQ
Cd =
1.15
1.60
1.60
1.60
1.60
RE (psi) =
634
634
634
634
1
Fc (psi) =
578
596
596
596
634
fc (psi) =
449 OK
192 OK
385 OK
385 OK
596
115 OK
M (Ib -ft) =
0
53
40
56
1
Fb' (psi) =
1785
3240
3240
2484
75
2484
ib (psi) =
0 OK
209 OK
157 OK
219 OK
293 OK
CSR =
0.60 OK
0.20 OK
0.54 OK
0.64 OK
0.18 OK
A.., (in.) =
0.400
0.400
0.400
0.400
0.400
A (In.)=
0.000 OK
0.050 OK
0.054 OK
0.075 OK
0.100 OK
TRIMMER: KING STUD WIND INTERIOR ZONE:
Trimmer supports only vertical load ... King stud supports only bending ...
Peep (lbs) = 3036 Mcap (Ib -ft) = 827
trib width rapacity (ft) = 20.67 for M < Mcap
trib width capacity (ft) = 10.63 for 0 < L/ 240 (governs)
KING STUD WIND END ZONE:
KIND STUD EARTHquAKE:
King stud supports only bending ...
King stud supports only bending ...
Mcap (Ib -ft) = 827
Mcap (Ib -ft) = 634
trib width capacity (ft) = 20.67 for M < Mcap
trib width capacity (ft) = 11.32 for M < Mcap
trib width capacity (ft) = 10.63 for A < L 1240 (governs)
trib width capacity lel = R n9 1.
Interior Zone 2nd floor Interior USE: 2 X 4 @16 -O.C.
End Zone 2nd floor interior USE: 2 X 4 @ 16 " O.C.
(DF No. 2)
Framing at openings (unless noted otherwise on plan):
STUDS EO
OPENING WIDTH
NO. OF TRIMMERS
NO. OF KING
NO. OF KING STUDS
NO. OF KING
4
2
(FT)
5
2
1
1
1
6
2
1
1
1
7
3
1
1
1
8
3
1
j
1
9
3
1
1
1
10
3
1
1
2
11
4
I
1
2
12
4
1
1
2
13
4
1
1
'e
14
5
1
1
15
5
1
2
18
5
1
1
i
2
2
.
STUDS INT ZONE
END ZONE
STUDS EO
3
1
1
1
1
4
2
5
2
1
1
1
6
2
1
1
1
7
3
1
1
1
8
3
1
1
1
9
3
1
1
1
10
3
1
1
2
11
4
1
1
2
12
4
1
1
2
13
4
1
1
'e
14
5
1
1
15
5
1
2
18
5
1
1
i
2
2
L1 < L / 240
(governs)
Project Name: Project #: Initials: Date: Sheet:
WOOD STUD WALL DESIGN
1D+1L+1S
1D+ lWend
1D+0.75L+0.75Wend+
1D+0.751-+0.525EQ+
NO. OF KING STUDS
NO. OF KING
0.75S
ALL WABLESTRES DESIG 10o5N S
0.61) + 0.7EQ
Cd =
1.15
1.60
1.60
DESCRIPTION: 3rd floor Interior
Axial
FcE (psi) =
Loads to Wall:
634
wLoad case
j
1.60
Height, Is (ft) : 8.0
a
DL
LL trib
1
2&3
4 &5
6
7
tlone <L/: 240
C& C Interior
or ZZone (psf): 5.0
0 roof
25
35 13.5
910
338
692
692
203
C& C End Zone (psf): 5.0
floor
wall
0
0
0 0
0
0
0
0
0
earthquake pressure (pso: 10.0
mist
2464
0 0
0
0
0
0
0
LL on roof snow? (YIN): y
0.400
0
0 0
0
0
0
0
0
o.aoo
0.054 OK
0.400
0.400
w (plf)=
810
338
692
692
203
Lumber grade: 2
(DF No. 2) NDS 2005
2
1
1
2
13
TRIMMER: KIND STUD WIND INTERIOR ZONE:
Trimmer supports only vertical load ... King stud supports only bending ...
Pcap (lbs) = 3036 Mcap (Ib -ft) = 827
trib width capacity (fl) = 20.67 for M < Mcap
trib width capacity (ft) = 10.63 for A < L / 240 (governs)
KIND STUD WIND END ZONE: KIND STUD EARTHQUAKE:
King stud supports only bending ... King stud supports only bending ...
Mcap (Ib -ft) = 827 Mcap (Ib -ft) = 634
trib width capacity (ft) = 20.67 for M < Mcap Crib width capacity (ft) = 11.32
trib width capacity (ft) = 10.83 for A < I 1240 ------ ,... - _-
for M < Mcap
ori<L/240
Interior Zone 3rd floor interior USE: 2 X 4 @iG "O.C.
End Zone 3rd floor interior USE: 2 X 4 @ 16 " O.C.
(DF No. 2)
Framing at openings (unless noted otherwise on plan):
1D+1L+1S
1D+ lWend
1D+0.75L+0.75Wend+
1D+0.751-+0.525EQ+
NO. OF KING STUDS
NO. OF KING
0.75S
0.75S
0.61) + 0.7EQ
Cd =
1.15
1.60
1.60
1.60
1
FcE (psi) =
634
634
834
j
1.60
Fc (psi) =
578
596
596
634
634
to (psi) =
206 OK
86 OK
178 OK
598
176 OK
596
M (Ib -ft) =
0
53
1
1
51 OK
FV (psi) =
1785
3240
40
3240
56
75
Ib (psi) =
0 OK
209 OK
157 OK
2484
2464
CSR=
0.13 OK
0.10 OK
0.15 OK
219 OK
293 OK
4m„ (in.) =
0.400
0.400
0.21 OK
0.14 OK
4 (in.) =
0.000 OK
0.050 OK
o.aoo
0.054 OK
0.400
0.400
11
2
1
1
0.075 OK
0.100 OK
TRIMMER: KIND STUD WIND INTERIOR ZONE:
Trimmer supports only vertical load ... King stud supports only bending ...
Pcap (lbs) = 3036 Mcap (Ib -ft) = 827
trib width capacity (fl) = 20.67 for M < Mcap
trib width capacity (ft) = 10.63 for A < L / 240 (governs)
KIND STUD WIND END ZONE: KIND STUD EARTHQUAKE:
King stud supports only bending ... King stud supports only bending ...
Mcap (Ib -ft) = 827 Mcap (Ib -ft) = 634
trib width capacity (ft) = 20.67 for M < Mcap Crib width capacity (ft) = 11.32
trib width capacity (ft) = 10.83 for A < I 1240 ------ ,... - _-
for M < Mcap
ori<L/240
Interior Zone 3rd floor interior USE: 2 X 4 @iG "O.C.
End Zone 3rd floor interior USE: 2 X 4 @ 16 " O.C.
(DF No. 2)
Framing at openings (unless noted otherwise on plan):
OPENING WIDTH
(FT)
NO. OF TRIMMERS
NO.OF KING
NO. OF KING STUDS
NO. OF KING
STUDS INT ZONE
ENOZONE
STUDS EO
3
1
1
1
1
j
4
1
5
1
1
6
1
1
1
1
7
1
1
1
1
I
8
2
1
I
1
0
2
1
1
1
10
2
1
1
2
11
2
1
1
2
I
12
2
1
1
2
13
2
1
1
2
14
2
1
1
2
15
3
1
1
2
16
3
1
1
2
(governs)
Project Name: Project #: nitials: Dare: Sheet:
MASONRY BLENDER WALL DES113N
M equations bsted on 12C 2000 SemADISA and JAG 63002 Section 325)
PROJECT: XXX
WALL MARK: XXX
WALL DATA: XXX
T.O. parapetelev (8): IS 00
T.O. wall Slav (R): 9.00
Base Mad (R) : 0.00
fm (PS): 1500
Fy(ks): 60
Wall self wt (PSG ; 55
Equiv Thick (N): 4.90
r(Jn): 2.59
If (In): 3.81
face shall (m): 1.25
LOAD DATA:
11 : 0.5
C! : 0.2
Snow Loads?: N
SPECIAL INSPECTION REQUIRED.
Solid Grouted?: N
Nom. Wall Thick (in):
e
Nom. Jamb Thick (In):
8
Vertical Reber [#]
5
Vert. Relnf spacing:
32
Center Reban (YIM
y
Min As Hertz DrVft): 0.04
1#5AT 48"Do. )
Min Aa Vent pnVft) 0.04
0
Equly Ven As pn2h): 0.12
As mia OK
Equiv Hodz As pn2/9): 0.08
OK
Seismic Design Data:
7SCSX00-6A9c=7aw
SDI: 0.500
la: 1.00
P: 1.00
(IBC Eq 1683) Fp : 0.20 Ww
FP(PSG: 11.0
(IBC Eq 16-28) Ev: 0.100 D
SERVICE LOAD DATA:
DL aq
LL I)
TO (ft)
dlnmreaef
PaI
a(in
Roof Ledger Load 1 (PSG:
25
35
2.0
2.00
5.81
Roof Ledger Load 2 (psq:
0
0
0.0
0.00
3.81
Floor Ledger Load (PSI:
0
0
0.0
0.00
3.81
Roof Concentric Load( psq:
0
0
00
-
_
Floor Concentric Load(ps):
0
0
0.0
-
--
Roof Concentrated Load (Wp):
0.00
0.00
-
0.00
3.81
Floor Concentrated Load (Kip) :
0.00
0.00
-
0.00
3.81
Wall Self WI (kln:
-
-
_
_
-
Wallendo enin La out R)
LeRO ening Iamb RightO ening
Gravity Lateral witllh Lateral Gravlly
0.00 0.00 1.0 1 0.00 0.00
Calculated Max. Jamb Width (a): 1,00
Lateral Uniform Lead Concenln%.: 1.00
Gavlty Uniform Load CenCenbaticn: 1.00
Gravity Conoentraell Lead Distribution: 1.00
Wind Design Data:
1.4D
1.11
0.02
0.00
0.00
0.02
0.00
1.2D0eLe0.5Lr/S
0.99
0.02
0.00
0.00
0.02
0.00
h'R:
14.2 OK
(AIDS 7-9.9 ar474w
1.2000EIF11.
1.03
0.02
O.OD
0.11
0.13
0.00
0.90H.OE
0.79
0.01
0.00
0.11
0.12
COD
Vad bar clear cover pn):
2.25
Design Wind Pressure(psq:
22.0
Em(ps);
1,350,000
n;
21.5
0.73
0.80
1,91
ands OK
>Mu. aK
[Act }28)
0.73 Ion, OK
0.80
1,89 "Ju. CK
0.73 a1Mn. Cm
0.80
1.90 -A..OK
Pt
: 0.80
0.]3 Na,eOK
O.BD
1,90 aMI. OK
0.]3 enA¢OK
.0.80
1.84 > Mu. OK
0.]3
0.60
1.83
No 01
1MU.OK
Ag (in211q:
58.8
30
0.03
0.72
0.03
0.72
.2
0.25
0.72
Ig (n4/ t):
344
29
0.09
0.72
29
0.23
0.72
(3-2)
fr (ps)
: 97
S (In3/R)
: 2D
Bearing
Wtllh(it) We (WIG
w11dq
WUfikIG
Ws(kl
- 0.05
-
0.07
0.00
- 0.00
-
0.00
0.00
- 0.00
0.00
-
- 0.00
--
0.00
0.00
- 0.00
0.00
-
_
0.150 0.00
-
0.00
0.00
0.00 0.00
0.00
-
- 0.74
--
-
-
CODE CHECKS:
Ult. Vert stress (psi): 19 am fm(psi): 75 OK pec 2108.9.4) Nm 53002323)
p: 0.0025 Pmax: 0.0088 OK (@C2109.e 2132)
WALL ANALYSIS:
Load Combos:
Pu":
Pu•e/2 D, Me:
Mu MmlikM):
IOU seismic IS Mc:
Final MU TOTue;-fie:
Au rn)1
1.4D
1.11
0.02
0.00
0.00
0.02
0.00
1.2D0eLe0.5Lr/S
0.99
0.02
0.00
0.00
0.02
0.00
1.213tIALUS011.
1.D8
0.04
0.00
0.00
0.04
0.00
1,2D.lSIU/S+0SW
4.06
0.04
0.18
0.00
0.22
0.01
1.2DH.SWH1 L+CSIUr5
0.99
0.02
0.36
0.00
0.36
0.01
1.2000EIF11.
1.03
0.02
O.OD
0.11
0.13
0.00
0.90H.OE
0.79
0.01
0.00
0.11
0.12
COD
0.9D.ISW
0.71
0.01
0.36
0.00
0.37
0,01
1}zs1
1}2a)
(IBC 210SAAS) (ACI 3-321
Mar lx Mq:
Bexura 4:
(ACI -27) 21 Mn lk'Mt)1
0.73
0.80
1,91
ands OK
>Mu. aK
[Act }28)
0.73 Ion, OK
0.80
1,89 "Ju. CK
0.73 a1Mn. Cm
0.80
1.90 -A..OK
0,73 aran.OK
0.60
1.90 >Au. cK
0.73 -Nn.OK
0.80
1.89 >Mu. OK
0.]3 Na,eOK
O.BD
1,90 aMI. OK
0.]3 enA¢OK
.0.80
1.84 > Mu. OK
0.]3
0.60
1.83
No 01
1MU.OK
1" (04):
service30
Initial M=0.00 had:
dmax=O.OWh M1:
(IBL 3108.9.4.6) NCI }90,31)
30
0.01
0.72
30
0.03
0.72
0.03
0.72
.2
0.25
0.72
30
' 0.25
0.72
30
0.09
0.72
29
0.09
0.72
29
0.23
0.72
(3-2)
FOUNDATION ANALYSIS:
Max P service (WB) : 0.86 al mid hl of wall Allowable ..It bearing (psi): 1500
Addl lower wall wl(kM): 0.25 Req'd wall fig width (it): (Unless other foundation design Gala Included)
Total at base of wall (WR):' -1'i'1 -
Profit TdEfl WbD ask.S.1 +3. =la Project #: Initials: Date: Sheet:
ALLOWABLE STRESS DESIGN
COLUMN MARK: Cl
LOADS:
LEVEL 1
elev. (8): 9.00
C 0.00 0.00 - 0.00 - 0.00
D 0.00 0.00 0.00 0.00
A 9.80 3.60 3.00 - 29.40 -
8 4.00 1.13 -3.00 - -12.00 --
LOAD
P, (k)
P.,(k)
0. (in)
a, (in)
Pen
PeyrL Comments
LEVEL3
A
7.60
3.60
3.00
-
22.80
- <-
elev. (0): 26.00
B
0.00
0.00
0.00
M,y:
0.00
-
elev. (ft): 0.00
0
0.00
0.00
--
0.00
-
0.00
COLUMN INTERACTION:
D
0.00
0.00
1
0.00
0.22
0.00
LEVEL2
A
9.80
3.60
3.00
-
29.40
- <-
elev, (t): 18.00
B
4.00
1.13
-3.00
-
-12.00
KVry: 49.74
LEVEL 1
elev. (8): 9.00
C 0.00 0.00 - 0.00 - 0.00
D 0.00 0.00 0.00 0.00
A 9.80 3.60 3.00 - 29.40 -
8 4.00 1.13 -3.00 - -12.00 --
LEVEL 2...
C
0.00
0.00
--
0.00
--
0.00
46 ksl
D
0.00
0.00
-
0.00
--
0.00
FOUNDATION
kip
35.20
55.96
Ix: 16
M,y:
209.6 kip -in
16
elev. (ft): 0.00
Sx: 6.41
in?
Case
Pr
FR.
Ma
M./M.
COLUMN INTERACTION:
M,/My
H14
Z,: 7.610
1
21.40
0.22
LEVEL3...
0.08
0.00
0.00
0.30
Ox
2
18.53
MID: 49.74
29.40
M,x:
209.6 kip -in
0.00
P,:
100.3
kip
KVry: 49.74
0.22
M,y:
209.6 kip -in
0.00
0.00
0.22
CK
Case Pr
FR.
Mrx
Mrx/M,x
Mry
MOJM,y
Hi -1
0.24
1 7.60
0.08
22.80
0.11
0.00
0.00
0.15
Du
2 7.60
0.08
22.80
0.11
0.00
0.00
0.15
OK
3 7.60
0.08
0.00
0.00
0.00
0.00
0.04
OK
4 7.60
0.08
22.80
0.11
0.00
0.00
0.15
OK
LEVEL 2...
HSS5x5x114
Fy =
46 ksl
KVm:
55.96
in?
MO:
209.6 kip -in
In.
P,:
95.9
kip
KVry:
55.96
Ix: 16
M,y:
209.6 kip -in
16
in 4
Sx: 6.41
in?
Case
Pr
FR.
Ma
M./M.
Mry
M,/My
H14
Z,: 7.610
1
21.40
0.22
17.40
0.08
0.00
0.00
0.30
Ox
2
18.53
0.19
29.40
0.14
0.00
0.00
0.24
OK
3
21.40
0.22
0.00
0.00
0.00
0.00
0.22
CK
4
18.53
0.19
29.40
0.14
0.00
0.00
0.24
OK
LEVEL I...
KVrx:
55.96
Mcx:
209.6 kip -in
P,:
95.9
kip
KVry:
55.96
M,y:
209.6 kip,4n
Case
Pr
PR/
%
MWMcx
Mry
Mr1mg
Hi -1
1
35.20
0.37
17.40
0.08
0.00
0.00
0.44
OK
2
32.33
0.34
29.40
0.14
0.00
0.00
0.46
OK
3
35.20
0.37
0.00
0.00
0.00
0.00
0.37
OK
4
32.33
0.34
29.40
0.14
0.00
0.00
0.46
OK
COLUMN SIZE:
HSS5x5x114
Fy =
46 ksl
A: 4.3
in?
t:
0.233
In.
b: 5
in.
d:
5
In.
Ix: 16
in.4
ly:
16
in 4
Sx: 6.41
in?
Sy:
8.41
In?
Ix: 1.93
in.
ry:
1.93
In.
Z,: 7.610
in 3
Zy:
7.61
in 3
Tp
ar
b/l- 18.50
28.12
35.15
IA 18.50
28.12
35.15
Kx: 1.00
Cw:
10.5
Ky: 1.00
J:
25.8
Fy: 46
h:
5
PLAN -TYPICAL COLUMN
CASE I: FULL DL+LL
CASE2: OL + unbal LL abI Y-AXIS
CASE 3: DL• unbala abl X-PXIs
CASE 4: M. unbal LL abl X 6 Y-AXES
Project Name: Project #: Initials: Date: Sheet:
ussC ..07.01.11xla
ALLOWABLE STRESS DESIGN
COLUMN MARK. C2
LOADS:
COLUMN INTERAOTION:
LEVEL 3...
LOAD
P, (k)
Podk)
a. On)
erlin)
P.e,,
PeeTL Comments
LEVEL3
A
0.00
0.00
0.00
-
0.00
--
elev. (ft): 0.00
B
0.00
0.00
0.00
-
0.00
-
Case
C
0.00
0.00
-
0.00
-
0.00
1
0
0.00
0.00
0.00
0.00
0.00
0.00
LEVEL 2
A
5.13
1.50
3.00
--
15.39
---
elev. (fl): 18.00
8
0.00
0.00
0.00
-
0.00
-
4
C
0.00
0.00
-
0.00
--
0.00
LEVEL 2...
D
0.00
0.00
0.00
0.00
LEVEL 1
A
5.13
1.50
3.00
-
15.39
-
elev. (fl)'. 9.00
B
0.00
0.00
0.00
-
0.00
-
Case
C
0.00
0.00
-
0.00
-
0.00
I
D
0.00
0.00
-
0.00
-
0.00
FOUNDATION
5.13
10.26
15.39
0.23
0.00
0.00
0.30 OK
elev. (81: 0.00
5.13
0.14
0.00
0.00
0.00
0.00
0.07 OK
COLUMN INTERAOTION:
LEVEL 3...
HSS3x3x1/4
Fy = 46 ksl
A: 2.44
KVm:
0.00
0.233 in.
Mnx:
68.3 kip -in
d:
Pe:
#DIV/01
KVry:
0.00
3.02 in
Mcy:
68.3 kip -in
Sy:
2.01 in.'
N: 1.11
Case
Pr
PR.
III,
MIx/Mcx
MIy
M,/My
Hi -1
1
0.00
#DIV/01
0.00
0.00
0.00
0.00
#DIV/01
2
0.00
4DIV/01
0.00
0.00
0.00
0.00
#DIV/01
3
0.00
#DIV/01
0.00
0.00
0.00
0.00
#DIV101
4
0.00
#DIV/01
0.00
0.00
0.00
0.00
#DIV/01
LEVEL 2...
Klhx:
97.30
Mex:
68.3 kIp-in
Pc:
35.6 kip
KVry:
97.30
Mey:
68.3 kip -in
Case
Pr
P,/Pe
Ma
Mrx/Mex
Mry
Mr IMey
H7-1
I
5.13
0.14
15.39
0.23
0.00
0.00
0.30 OK
2
5.13
0.14
15.39
0.23
0.00
0.00
0.30 OK
3
5.13
0.14
0.00
0.00
0.00
0.00
0.07 OK
4
5.13
0.14
15.39
0.23
0.00
0.00
0.30 OK
LEVEL 1 ...
KYm:
97.30
Mex:
68.3 kip -in
Pc:
35.6 kip
KVry:
97.30
Mey:
68.3 kip -in
Case
Pr
P,/Pc
Mx
Mn,/Mnx
Mry
Mry/Mey
Hi -0
1
10.26
0.29
15.39
0.23
0.00
0.00
0.49 CK
2
10.26
0.29
15.39
D.23
0.00
0.00
0.49 OK
3
10.26
0.29
0.00
0.00
0.00
0.00
0.29 OK
4
10.26
0.29
15.39
0.23
0.00
0.00
0.49 OK
COLUMN SIZE:
HSS3x3x1/4
Fy = 46 ksl
A: 2.44
In.'
t:
0.233 in.
b: 3
in.
d:
3 in.
Ix: 3.02
in �
ly:
3.02 in
<-- Sx: 2.01
in.'
Sy:
2.01 in.'
N: 1.11
in.
ry:
1.11 in.
Ze: 2.480
In.
Zr:
2.48 in..
-
Xp
Ar
b/t= 9.88
28.12
35.15
hR 9.88
28.12
35.15
Kx: 1.00
Cw:
3.52
Ky: 1.00
J:
5.08
Fy: 46
h:
3
PLAN - TYPICAL COLUMN
CASE 1: FULL DL -LL
CASE2: DLevnbal LLWY-AXIS
CASES: DL,rIbWtL.bl X -MIS
CASE4: DL,IbSlLLaWX6%AXES
Project Name: Project #: Initials: Date: Sheet:
HSSCW.W.01.1Exle
VC
WOOD POST DESIGN
DOUGLAS FIR LARCH
ALLOWABLE STRESS DESIGN
ALLOWABLE LOADS (KIPS)
LOAD DIIRATIONI Do = 1.15
ALLOWABLE LOADS (KIPS)
LOAD DURATION, Do = 1.00
ALLOWABLE
UNGRADED HEIGHT OF POST, LE (FT) BEAM
POST
8
9
10
12
14
16
18
20 BEARING
2x4 stud'
2.5
2.1
1.7
1.2
0.9
--
---
-- 3.3
2r.4 no 2*
31
..2.5
20'
1.4"
1.1 -
20
--
33
2 x 6 stud'
TO
6.3
5.6
43
3.3
2.6
2.1
1.7 5.2
2X6 no. 2'
95.
9.2
P.0
5.2
'4.0. .
3'.1 -
2.5 -
2.0 52 -
4 x 4 no. 2
7.1
5.7
4.7
3.3
2.5
---
---
--- _ 7.7
4x6,no.2
-11.1
9.0
7.4
53
3.9
-
-
-- 12.0
4 x 8 no. 2
14.6
11.8
9.8
6.9
5.1
---
--
--- 15.9
6x6 no.2
20.0
- 18.6
1TO
13.7
10.9
8.7
Tl
-5.8 18.9
6 x 5 no. 1
27A
25.0
22.4
17.6
13.8
10.9
8,8
7.2 18.9
ox8'no.2
2T3
25A
23.1
- 187
14.8
11.9
9.6
7.9 25.3
6 x 8 not
37.3
340
30.5
24.0
18.8
14.9
12.0
9.9 25.8
9.5
,58,3,-
.,,562
536,;
47.4
40,4 -.
t33�dy;o,
;, 282
23.6. 352._„_.
ALLOWABLE LOADS (KIPS)
LOAD DURATION, Do = 1.00
'Wall sheathing braces stud in weak axis bending
Project Name: Project #: Initials: Date: Sheet:
.dR.d NJN2
UNGRADED HEIGHT OF POST, LE (FT)
ALLOWABLE
BEAM
FIST
8
9
10
12
14
16
18
20
BEARING
2 x 4 stud'
2.5
2.0
1.7
1.2
0.9
---
--
---
3.3
2x4 no.2'
3A
24
20
14
1.1
--
-
-
33
2x6 stud'
6.4
59
5.3
42
3.3
2.6
2.1
1.7
5.2
2,<5 CO.
5.2
4 x 4 no. 2
7.0
5.7
4.7
3.3
2.5
--
...
--
7.7
4x6 no.2
703.
8.9
7A
.
3.B
---
-_
'12.0'.
4 x 8 no. 2
14.3
11 7
9.7
6.9
5.1
...
---
---
15.9
6x6 no.2.
13.0
17.0
.157
13.0
105
3.5
7D
53
13,9:
6x6 no.1
24.8
230
21.0
16.9
13.4
10.7
8.7
T2
18.9
6x8 no.2
24,6
23.1
21.4
-17.8
14A
11.6 -
9.5
-7.9
25.6
6x8 no.
33 9
3� e
92 C
23.0
18.3
14.6
11 9
9.8
25.8
8x8 no.-
516;,;1
50.0..
- A62 I
.;93.5 I,,
3B.0.,,
,32.4 -
- 27A
.23,1.
352 -
'Wall sheathing braces stud in weak axis bending
Project Name: Project #: Initials: Date: Sheet:
.dR.d NJN2
3- STORY WOOD SHEARWALL
LINE- A
3rd Floor Walls
Znd Floor Walls
Lateral Farce: 6800 pit
Lateral Force:
2900 pit
1st
Floor Walls
Trb. Length: 1 R
Tnb. Length:
7
Lateral Force:
2900
pit
Less due to geo: 0 Ib
Less due to geo:
R
0
Ttlb. Length:
i
ft
p: 1,00
pit
Less due to geo:
0
pif
Total Well Lentilh:95 R
P:
Total Wall Length:
1.00
95 fl
p:
7.00
Short Well Length: 3 It
Short Wall Length:
3
Total Wall Length:
95
it
WeII Height e R
Fir Depth:
1 R Wali Height:
it
8
Short W811 Length:
3
R
Root DL: 20 Pat
9
it
Fir Depth:
1 It Well Height
e
it
Tab. Width: 6 ft
Floor DL:
20 Psf
Floor DL:
psf
Wall Weight 15 psf
Width:
Tnb. Width:Ttlb.
6 ft
Width;
6
6
R
DL tactor: 0.53
Wall Weight
15 psf
Wall Weight
15
psf
Forceithlevel, Fs: 6800 Ib
DL lac,
0.53
DL tactic
0.53
Force total, Fr 6800 Ib
F:
F2:
29pp Ib
Fr:
2900
ib
Sheer level, Vs: 72 pit
Wall
F*:
9700 Ib
Fr:
12600
Ib
Total shear, VT: 72 pit
A
V2.
pit
Wail
V-:
pit
Wall
Total O.T.M: 54400 ft'Ib
Vr:
Total O.T.M:
100 2 pH
738800 R'Ib
A
Vr:
f]3 3
pit
q
Short Wall1717.895 ft -lb
Short Wall O.T.M:
2450.5263 ft -lb
Total O.T.M:
249300
ft -lb
all MR:
Short Wall Ms: 1080 RIb
Short Wall Ms:
2160
Shod Wellall
3183
ft9b
UPNI0level. P3: 381 to
Strap
Ps:
R'Ib
625
Shod Wall M
MR:
R:
Rib
Total UpliR Pr: 307 Ib
NIA
Pr:
Ib
H
P-:
869
869
Ib
Holdown
433 Ib
N/A
N/A
Pr:
408
Ib
NIA
LINE; D
3rd Floor Walls
2nd Floor Walls
Lateral Force: 6800I(
P
Lateral Force:
2900 pit
1st Floor Walls
Tdb. Length: 1 11
Trib. Length:
7
Lateral Force:
2900
pit
Less due to geo: 0 Ib
Less due to geo:
ft
0
Tdu Length:
1
ry
p: 1.00
pit
Less due to geo:
0
pit
Total Wall Length: 52.5 fl
p;
Total Wall Length:
1.00
52.5 R
P
1.0
Short WeII Length: 28 ft
Shote Well Length:
20
Total Wall Length:
52.5
fl
Wall Height 6 R
Fr Depth:
i R Wall Height
ft
8
Shod Wail Length:
28
ft
Roof DL: 20 pat
R
Fir Depth:
1 R Wall Height
8
it
Tab. VWdth: 10 fl
Floor DL:
20 Pat
Floor
psf
Well Weight 15 pst
Ttlb. eight
10 fl
the
hib.Wdih:
6
6
ft
OL factor. 0.53
Wall Weight
15 ps(
Well Weight
15
ps(
Force IN level, Fs: 6800 Ib
OL factor.0.53
DL tactic
0.53
Force total, Fr: 6800 to
F,:Fr:
2900 Ib
F-:
0
Ib
Shear level, V2: 130 pit
Wall
Fr:
V2:
9700
Fr:
26
125
Total shear, Vr: 110 pit
q
VT:
55to
Pit
Pi
Wall
V-:
pi f
pi
Wall
Total O.T.M: 54400 ft•Ib
Tp1a10.7.M:
185 Pit
738800 ft -lb
A
VT:
24
pl!
q
29013.33 Rlb
Short Walsall
Short Wa00.T.M: 41386.66]
ft -lb
Total O.T.M:
249300
Rib
MR:
Short Wall Me: 125440 ft -lb
Short WeII MR:
250880 INS
Short Wall O.T.M:
53760
ft -lb
Uplift ® level, Ps: 0 Ib
Strap
P2:
Short Wall MR:
321440
Total Uplift, Pr: 0 to
NIA
Pr:
-909 It
Holdown
577
It
It
Holdown
0 Ib
NIA
T:
Pr:
0
to
NIA
LINE: a
3rd Floor Walls
2nd Floor Walls
Lateral Farce: 0I(
P
Lateral Force:
0 pit
list Floor Walls
Tdb. Length: 0 R
Trib. Length:
0
Lateral Farce:
2900
Pit
Less due to geo: 0 to
Less due to geo:
ft
0 pif
Tab. Length:
1
fl
p: 1.00
leas due to gee:
0
pit
Total Wall Length:0 R
P:
Total Wall Length:
too
0 fl
p:
7.00
Short Weil Length: 0 R
Short Wall Length:
0 it
Total Wail Length:
13
fl
Wall Height 0 ft
Fr Depth: 1
ft Wall Height
0 fl
Length:6
Shote Well
fl
(Strap Heatley)
Roof DL: 0 psf
Floor DL:
Fir Depth: 1
it Height
al
Tdb. Width: 0 fl
Trib. Width:
0 pal
0
Floor DL
psf
Wall Weight 0 pst
WeII Weight
R
0
Tdb. Wltlth:
a
e
fl
DL 0.60
DL factor.
psf
0.60
WeII Weight:
15
psf
F.:
Force Ith level,el. Fs: D Ib
DL Fedor.
O.6.BD
For
Force total, Fr: 0 Ib
F2:
0 to
F-:
2900
to
Shear@level, V.: #DIV/01 pit
Wall
Fr:
V2: #DM01
0 Ib
Fr:
2800
Ib
gDIV/01 pit
TotalTotal
A
Vr: #DIV/01
pif
Wail
VT:
223
pit
Wall
TM:
Total O.T.M: 0 I'll,
Pit
A
Vr:
pit
p
Short Well0 Rlb
Total D.T.M:
Short Well D.T.M:
0 fl'Ib
Total O.T.M:
32J
23200
ft -lb
all MR:
Shod WeII MR: 0 fl•Ib
Short WeII MR:
0 Wit
ShShdWall Wall .R:
23200
Rib
Uplift @level, Ps: gDIV/01 Ib
Strap
PS: #DIV/01
0
Short Well Ma:
32400
Total Uplift. Pr: #DN/01 Ib
NIA
It
r It
Pr:
Holtlown
Pr:
705
ltrib
b
Ib
H
#DIV/01
Ib
N/A
Pr:
209
Ib
N/A
N/A
Project Name: 11 Project #: nitials: Date: Sheet:
..s.4san2
3- STORY WOOD SHEARWALL
2and5
LINES
i and
3rd
Floor Walls
2nd Floor
2nd Floor
Walls
3rd
Floor Walls
2nd Floor Walls
Lateral Force:
5730
1st Floor
Walls
Lateral Force:
Lateral Force:
2500
pH
Lateral Force:
Lateral Force:
2060
pit
THIS. Length:
Lateral Force:
2060
pit
Tdb. Length:
1
ft
Tdb. Length:
Tnb. Length:
1
It
Less due to geo:
Tdb. Length:
1
ft
Less due to geo:
0
Ib
pit
Less due to geo:
0
pit
pit
Less due to geo:
0
pit
p:
1.00
IF :
1.00
p:
1.00
IS :
1.00
p:
1.00
Total Wall Length:
Total Wall Length:
15.5
ft
Total Wall Length:
Total Well Length:
15.5
ft
Total Wall Length:
Total Wall Length:
15.5
It
Shod WeII Length:
15.5
It
Shod Wall Length:
Shod Wall Length:
15.5
If
Shod Wall Length
Short Wall Length:
15.5
ft
WaII Haight
0
ft
Fir Depth:
7 ft Wail Height
8
ft
Flr Depth:
1 ft Wall Height
e
in
Roof DL:
20
par
20
Floor DL:
20
pat
20
Floor OL:
20
pat
Tdb. Width:
2
ft
Tdb. Width:
THIS. Width:
2
ft
Tdb. Width:
Tdb. Width:
2
ft
Wag Weight
20
psf
Wali Weight
Wall Weight:
20
pat
WeII Weight
Wall Welght:
20
psf
DL factor.
060
15
psf
DL factor.
0.60
060
OL factor
060
0.60
Force A level, F3:
2500
Ib
0.60
Fs:
2060
Ib
5730
Fr:
2060
F2:
Force total, Fr:
2500
Ib
Fr:
FT:
4560
to
Force total, FT:
5730
to
to
Sheer Lr9 level, V3:
181
pit
Wall
V2:
133
pit
Well
Fr:
6620
to
Total Shear, VT:
161
pft
A
VT:
294
pit
A
V2:
133
pit Wali
Total O.T.M:
20000
MIb
426
Total O.T.M:
58980
ft9b
192
VT:
Total O.T.M:
427
116500
pit B
frib
Shod Wall 07.M:
20000
fl lb
Total O.T.M:
Shod Wall O.T.M:
56980
ft'Ib
VT:
Total O.T.M:
Shod Wall O.T.M:
116500
MIb
Shod Wali MR:
24025
rib
Shod Wall O.T.M:
Shod Wall MR:
48050
Mlb
Total O.T.M:
Shod Wall Ma:
72075
Mlb
Uplift @level, PS:
360
to
Strap
P2:
1424
Ib
11o1dow0
Pt:
2487
144060
Total Uplift, PT:
360
Ib
NIA
PT:
1645
Ib
MSTC40
Ib
HoltlownP,:
Ib Holdown
Mlb
Total Uplift PT:
Total Uplift, PT:
685
Ib
NIA
PT:
PT:
4726
to HTTS
LINES
2and5
3rd
Floor Walls
2nd Floor
2nd Floor
Walls
1s1 Floor Walls
let Floor Walls
Lateral Force:
Lateral Force:
5730
pit
Lateral Force:
Lateral Force:
4700
pif
Lateral Force:
Lateral Force:
4700
pit
Tdb. Length:
THIS. Length:
1
ft
Tdb. Length:
Tib. Length:
1
ft
Tdb. Length:
Tdb. Length:
1
ft
Less due to geo:
Less due to geo:
0
It,
Less due to geo:
Less due to geo:
0
pit
Less due to geo:
Less due to geo:
0
pit
p:
IS :
1.00
p:
IF :
1.00
p:
IS :
1.00
Total Wall Length:
Total Wall Length:
24.5
ft
Total Wall Length:
Total Wall Length:
24.5
8
Total Well Length:
Total Wall Length:
24.5
ft
Shod Wall Langlh:
Shod Wall Length:
24.5
ft
Shod Wall Length:
Shod Wall Length:
24.5
ft
Shod Wall Length
Shod Wall Longth:
24.5
ft
Wall Height:
Wall Height:
6
ft
Fir Depth: 1
ft Wall Height
8
ft
Fir Depth:
1 ft Wall Height
8
ft
Roof DL:
Roof DL:
20
psf
Floor DL:
Floor DL:
20
Pal
Floor DL:
Floor DL:
20
pat
THIS. Width:
Tdb. Width:
2
fl
Tdb. Width:
Tdb. Width:
2
a
Tdb. Width:
Tdb. Width:
2
In
Wali Weight
Well Weight:
15
psf
WeII Weight
Wall Weight:
15
par
Wall Weight
Well Weight
15
psf
DL factor.
DL factor.
060
DL Sector.
DL factor.
0.60
DL factor.
OL factor.
0.60
Force ith level. F2:
Force lth level. Fs:
5730
it,
F2:
F2:
4700
Ib
Fr:
4700
Force lolal, FT:
Force total, FT:
5730
to
Fr:
FT:
10430
Ib
F{
3950
to
IS
Shaw @level, V2:
Sheer @ level, Vs:
234
pif
Wall
V2:
192
pit
WaII
FT:
15130
Ib
Total shear, VT:
Total shear, VT:
234
pit
A
VT:
426
pit
B
VI:
192
plf
Wall
Total O.T.M:
45840
MIS
Total O.T.M:
Total O.T.M:
135010
Wlb
VT:
VT:
Total O.T.M:
618
266480
pit
IM
C
Shod Wall aT.M:
45840
Mlb
Shod Wall O.T.M:
Shad Wall O.T.M:
135010
ft -lb
Total O.T.M:
Shod Wall D.T.M:
266480
fdIb
Shod Wall MR:
Shod WeII MR:
48020
MIB
Shod Well Ms:
Shod Wall Me:
95040
rib
Shod Wall O.T.M:
Shod WeII MR:
144060
It'll,
Uplift @level, Ps:
Uplift®level. Ps:
695
to
Strap
P2:
2230
Ib
HoltlownP,:
162240
Mlb
Total Uplift PT:
Total Uplift, PT:
685
Ib
NIA
PT:
3169
Ib
IASTC52
2675
3]64
Ib
Holtlown
Ib
N/A
PT:
Pt:
7349
to
HDO8
IJNE:
3 AND 4
3rd
Floor Walls
2nd Floor
Walls
1s1 Floor Walls
Lateral Force:
4850
pit
Lateral Force:
3850
pit
Lateral Force:
3950
pit
Tdb. Length:
1
ft
Tdb. Length:
1
ft
Tdb. Length:
1
A
Less due to geo:
0
IS
Less due to geo:
0
pH
Less due to geo:
0
pit
p:
1.00
p:
1.00
p:
1.00
Total Wall Length:
26
It
Total Wall Length:
26
In
Total Well Length:
26
it
Shod Wall Langlh:
26
ft
Shod Wall Length:
26
R
Shod Wall Length
26
ft
Wall Height:
a
h
Fir Depth: 1 fl
Wall Height
e
If
FirDepth:
1 ft Wall Height:
a
It
Roof DL:
20
par
Floor DL:
20
par
Floor DL:
20
pat
THIS. Width:
2
ft
Tdb. Width:
2
ft
Tdb. Width:
2
a
Wali Weight
15
psf
WeII Weight
15
psf
Wall Weight
15
psf
DL factor.
0.60
DL Sector.
0.60
DL factor.
0.60
Force ith level. F2:
4850
Ib
F2:
3950
to
Force lolal, FT:
4850
Ib
Fr:
8800
Ib
F{
3950
to
Shaw @level, V2:
187
pit
WaII
V2:
152
pit
Wall
FT:
12750
Ib
Total shear, VT:
187
pit
A
VT:
338
pit
B
VS:
152
Pit
Wall
Total O.T.M:
38800
ft -lb
Total O.T.M:
114050
ft'@
VT:
490
pit
C
Shod Well O.T.M:
38800
Mlb
Shod Wall O.T.M:
114050
MIS
Total O.T.M:
224850
Mlb
Shod Wall MR:
54080
ft'Ib
Shod Well Ms:
108160
rih
Shod Wall O.T.M:
224850
rib
Uplift @level, Ps:
244
Ib
Strap
P2:
1460
Shod Wall Me:
162240
Mlb
Total Uplift PT:
244
Ib
N/A
PT:
1891
Ib
Holtlown
Pi:
2675
Ib
Holdown
Ib
N/A
PT:
4904
Ib
NIA
Project Name: Project #: Initials: Date: Sheet:
r am.
SEISMIC LATERAL ANALYSIS
2006W ..6.n.1 Buildf, C -d. 11ASCE 2-05
E4uIW-0 W..1 Forte Pm dura
PROJ ECT NAME: Temple View -22 unit
1E:
1.00
R: 6.5
F,: 1.43
Occupancy Category:
II
CI: 0.02
Seismic Design Category:
D
Ss: 0.468
F v 2.15
Site Class:
D
Sos: 0.4434 (Eq. 11.4-1 $ 11.4-3)
SI: 0.162
Sof 0.2324 (Eq. 11.4-2 $11.4-4)
k:
1.00
TI,: 6.0 sec.
T: 0.175 sec. (12.8-7)
Governs=>
C.=Sosl(R/1):
0.088
(12.8-2)
Max C,= SDI!(R/I)T:
0.205
(12.8-3) (T equal or less than Tr )
Max C,= SD1(TJ/(R/I)T2:
-
(12.8-4) IT greater than TL )
Min Ce 0.5S1/(Rfl):
-
(12.8-6) (Siequal or greater than 0.6)
Min C.=
0.010
(12.8-5)
Seismic Base Shear (V) =C.W:
35.9k
(12.8-1)
Vertical Distribution of Seismic Forces (calculations
per ASCE 7.05 Section 12.8.3)
h.
W. W. h.
F.
V. V. (ASD)
Level
Roof
ft
kips kip -ft
kips
kips kips E (ASD)
3rd Floor
18
9
196.0 3,528
19.5
19.5 13.6 0.070 W
2nd Floor
9
165.0 1,485
8.2
27.7 19.4 0.035 W
165.0 1,485
8.2
35.9 25.1 0.035 W
Totals: 526
Forces
6,498 35.9
7-05 ._............
h• vvp. EWI EF, Fp. Fp. (ASD)
Level it s kips kips kips kips P kips
18 196.0 198 19.5 19.5 13.6
3rd Floor 9 165.0 361 27,7
14.6 10.2
2nd Floor 9 165.0 526 35.9 14.6
10.2
Out -of -Plane Forces and Diaphragm Anchorage (calculations per ASCE 7.05 Section 12.11)
Fp=0.41ES,Ww or 0.lWw (Ultimate) (ASD)
out -of -plana wall design farces =_> Fp: 0.18 Wp 0.13 Wp
Fp=0.81ES,^
Fpn,;n=400Sosls pit or 280 pit
anchorage to flexible diaphragm force =_> Fp: 0.35 Wp 0,25 Wp
__> Fp(min): 280 pit 200 pit
Project Name: Project #:nitials: Date: Sheet:
SEISMIC WEIGHT
ZONE 22 UNIT
LEVEL: ROOF
:"TALL
WALL TYPE EXTERIOR INTERIOR
TOTAL LENGTH (FT) 2413 ) 45
WALL HEIGHT (FT) S B
PARAPET (FT) D O
WALL (PSF) 2❑ 1 ❑
WEIGHT (K) ) 9.B 5 B
ROOF OR FLOOR
TOTAL AREA (FT- 2) 533❑
DEAD LOAD (PSF) 2S
LIVE / SNOW LOAD (PSF) 35
% SNOW / LIVE LOAD (PSF) 20%
WEIGHT (K) 170.6
SEISMIC WEIGHT (K) : 196.2
Project Name: Project #: Initials: Date: Sheet:
SEISMIC WEIGHT
WEIGHT (K) 39.7 5.8
ROOF OR FLOOR
TOTAL AREA (FT �2) 456❑
DEAD LOAD (PSF) 25
LIVE/ SNOW LOAD (PSF) D
% SNOW / LIVE LOAD (PSF) D%
WEIGHT (K) 1 14 D
SEISMIC WEIGHT (K) : 159.5
Project Name: Project #: Initials: Date: Sheet:
ZONE : 22 UNIT
LEVEL :AND 2ND FLOORS
WALL
WALL TYPE
EXTERIOR
INTERIOR
TOTAL LENGTH (FT)
248
145
WALL HEIGHT (FT)
8
PARAPET (FT)
D
8
WALL (PSF)
40
D
10
WEIGHT (K) 39.7 5.8
ROOF OR FLOOR
TOTAL AREA (FT �2) 456❑
DEAD LOAD (PSF) 25
LIVE/ SNOW LOAD (PSF) D
% SNOW / LIVE LOAD (PSF) D%
WEIGHT (K) 1 14 D
SEISMIC WEIGHT (K) : 159.5
Project Name: Project #: Initials: Date: Sheet:
3• STORY WOOD SHEARWALL
2nd Floor Walls
let Floor Walls
Lateral Force:
LINE,
1 ands
Lateral Force:
5300
pif
Lateral Force:
5290
pit
Tdb. Length:
3rd
Floor Walls2nd
Tdb. Length:
Floor Walls
ft
1st Floor Walls
1
it
Lateral Force:
2500
Pit
to
Lateral Force:
2060
pit
pif
Lateral Force:
2060
pif
pif
Tdb. Length:
1
it
Tdb. Length:
1
P
Tdb. Length:
1
ft
Less due to geo:
0
ib
R
Less due to geo:
0
pit
11
Less due to geo:
0
pH
11
p:
1.00
26
If
P:
1.00
26
11
p:
1.00
26
11
Total Well Length:
15.5
If
It
Total Wal[ Length:
15.5
It
11
Total Wall Length:
15.5
ft
ft
Short Wail Length:
15.5
11
psf
Shod Wall Length:
15.5
11
psf
Shod Wall Length:
15.5
9
psf
Wall Height:
e
it
Flr Depth: 1
ft Wall Height
a
It
Fir Depth:
1 If Well Height
8
11
it
Roof DL:
20
poll
psf
Floor Of.
20
psf
par
Floor DL:
20
poll
psf
Tdb. Width
2
If
Tdb. Width:
2
ft
Trib. Width:
2
ft
Wall Weight
20
psf
to
Wall Weight
20
psf
to
Wall Weight
20
pet
Ib
DL factor
060
6440
to
OL factor.
0.60
11740
Ib
DL factor.
0.60
17030
Ib
Form ith level, F,:
2500
Ib
pit
Fs:
21160
Ib
If
Fr:
2060
It
pit
Force total, FT:
2500
to
pit
Ft:
4560
to
pit
Fr:
6620
Ib
pit
Shear®level, Va:
161
p0
Wall
Vs:
133
pill
Wall
V,:
133
p8
Wall
Total shear, VT:
161
pM
A
VT:
294
pit
A
VT:
427
p8
B
Total O.T.M:
20000
flit
ft -lb
Total O.T.M:
58880
ft9b
ft -lb
Total O.T.M:
116500
ft9b
ft9b
Short Wall O.T.M:
20000
111b
to
Short Wall O.T.M:
58980
Win
to
Shod WeII O.T.M:
116500
flit,
Ib
Shod Wall MR:
24025
ft9b
to
Shod Wall MR:
48050
ft'Ib
It
Short Well Me:
72075
flab
Ib
Uplift Clevel, Ps:
360
to
Strap
Ps:
1424
to
Holdown
pr:
2487
to
Heide.
Total Uplift, PT:
360
to
NIA
PT:
1945
to
MSTC40
PT:
4726
to
HITS
LIN E1
2 and 4
3rd
Floor Walls
2nd Floor Walls
1st Floor
Walls
Lateral Force:
5900
pit
Lateral Force:
4860
pit
Lateral Force:
4860
pit
Tdb. Length:
1
ft
Tdb. Length:
1
It
Tdb. Length:
1
11
Less due to geo:
0
to
Less due to geo:
0
pit
Less due to geo:
0
pill
P:
1.D0
p:
1.00
p:
1.00
Total Wall Length:
24.5
it
Total Well Length:
24.5
It
Total Wall Length:
24.5
It
Short Wall Length:
24.5
ft
Shod Wall Lenglh:
24.5
If
Shod Wall Length:
24.5
If
Wall Height
e
It
Fir Depth: 1
It Wall Height:
8
11
Fir Depth:
1 ft Wall Haight
e
It
Roof DL:
20
psi
Floor DL:
20
psf
Floor DL:
20
pat
Tdb. Width:
2
If
Tdb. Witlth:
2
If
Tdb. Width:
2
It
Wall Weight
15
pat
Wall Weight
15
psf
Well Weight
15
pat
DL factor.
0.60
DL factor.
0.60
DL factor.
0.60
Force is, love[. F3:
5900
Ib
Fs:
4660
to
F,:
4860
[b
Force total, FT:
5900
to
FT:
10760
to
FT:
15620
to
Shear®level. V3:
241
pit
Wall
Vs:
198
pif
Wall
V,:
198
pill
Wall
Total shear, VT:
241
pit
A
VT:
439
pill
B
VT:
630
pit
C
Total O.T.M:
47200
ft -lb
Total O.T.M:
139180
flit,
Total O.T.M:
274900
It'Ib
Shod Wali D.T.M:
47200
ft'Ib
Short Wall O.T.M:
139160
Wlb
Shod Wa0O.T.M:
274900
ni
Shod Wall MR:
48020
1196
Shod Wall MR:
96040
11.11,
Shod Well MR:
144060
fl -lb
Uplift @level, P,:
751
Ib
Strep
Ps:
2337
Ib
Holdown
Pt:
3924
Ib
Holdown
Total Uplift, PT:
751
Ib
N/A
PT:
3329
Ib
MSTC52
PT:
7692
It,
HDO8
3rd Floor Walls
2nd Floor Walls
let Floor Walls
Lateral Force:
6440
pit
Lateral Force:
5300
pif
Lateral Force:
5290
pit
Tdb. Length:
1
It
Tdb. Length:
1
ft
Tdb. Length:
1
it
Less due to geo:
0
to
Lass due to geo:
0
pif
Lass due to geo:
0
pif
P:
1.00
p:
1.00
p:
1.00
Total Wall Length:
26
R
Total Wall Length:
26
11
Total Wall Length:
26
11
Shod Wall Length:
26
If
Short Wall Length:
26
11
Shod Wall Length:
26
11
Wall Height
8
It
Fir Depth:
1 ft Wall Height
e
11
Fir Depth: 1
P Well Height:
8
ft
Roof DL:
20
psf
Floor DL
20
psf
Floor OL:
20
psf
Tdb. Width:
2
a
Tdb. Width:
2
11
Tdb. Width:
2
it
Wall Weight
15
psf
WeII Weight
15
par
Wall Weight
15
psf
DL factor
0.60
DL factor
0.60
DL factor.
0.60
Force Rh level, F,:
6440
to
F2:
5300
to
F,:
5290
Ib
Force total, FT:
6440
to
FT:
11740
Ib
FT:
17030
Ib
Shear@ level, V2:
248
pit
Wall
V,:
204
If
Well
V1:
203
pit
Wall
Total shear, VT:
248
pit
A
VT:
452
pit
B
VT:
655
pit
C
Total O.T.M:
51520
fllb
Total O.T.M:
151860
ft -lb
Total O.T.M:
299660
ft -lb
Shod Wall O.T.M:
51520
fl9b
Shod Well O.T.M:
151880
ft'Ib
Shod WaII O.T.M:
299860
ft -lb
Shod Wall MR:
54060
ft -lb
Shod Wall MR:
108160
ft -lb
Short Wall MR:
162240
ft9b
Uplift @level, P3:
734
to
Shap
P2:
2364
to
Holdown
P,:
3992
Ib
Holdown
Total Uplift, PT:
734
to
NIA
PT:
3346
It
MSTC52
PT:
7789
Ib
NIA
Project Name: 11 Project #: Initials: Date: Sheet:
..d.2
U111
3- STORY WOOD SHEARWALL
2nd Floor Walls
NEI
A
it
Force:
2750
pit
1st
Floor Walls
3rd Floor Walls
Tnb. Length:
2nd Floor Walls
H
Tnb. Length:
1
Lateral For.:
6000If
P
pit
lateral Force:
2
pit
Ib
1st Floor Wells
Less due to
Tnb. Length:
1
H
Tnb. Length:
Tnb.1 Length:
1
:
Lateral Force:
3750
DH
Less due to gee:
0
IbTnb.
Less due to geo:
0
ft
Length:
1
H
p:
1.00
52.5
ftp
:
pit
Less due to geo:
0
pit
Total Wall Length:
ft
28
p;
Total Wall Length:
1.00
82
ft
52.5
p.
1.00
Wall Height:
Short Wall Length:
3 3
ft
a Wall Height:
Short WeII Length:
3
Shod Wal Length:
Total Wall Length:
82
ft
Wall Haight:
e
ft
Fir Depth: 1
ft Wall Height
B
ft
Fir Depth: 1
Short WeII Length:
3
ft
Roof DL:
20
psf
ftFloor
Floor DL:
ft
Fir Depth: 1
ft Wail Height:
8
ft
Tnb. Width:
8
It
f5
Floor DL:
20
psf
10
Floor DL
20
psf
Wall Weight
R
psf
DL factor.
Tnb. Width:
6
ft
Wall Weight:
Trib. Width:
6
H
OL factor.
0.5S 3
psf
Wall Weight:
15
D sf
Wall Weight:
15
psf
Force i total, Fa:
DL factor.
It
DL factor,
r:
0.53
6000
Ib
DL facto r:
0.53
2750
Force
Force total, Fr:
6000
6000
It
50
Ib
2750
Ib
7f4
Fr:
3750
Ib
Shear@level, V3:
73
pit
Wali
VT:
8750
Ib
Total shear, VT:
FT:
12500
Ib
Total shear, VT:
73
pit
A
2
1
Flf
Wall
V':46
48000
pit Wall
Total O.T.M:
4600
H'@
pit
ft -lb
Total O.T.M:
124000
fl Ib
A
VT'
Shod Wall O.T.M:
pit q
Short Wall D.T.M:
7756.099 78 Wit,Wit,Total
Short Wall O.T.M:
Short Wall O.all
252160 8
ft-lbR-11)
O.T.M:
O.T.M:
232727 50
ft -lb
Shoff Wall Ma:
1080
H•Ib
Short Wall Ma:
Me:
2180
H'Ib
Shoji Wall
3659
H'Ib
UPlift ® level, Ps:
394
Ib
Strap
Strap
D
allO.T.M:
Shan Wall Me:
3240
ft'Ib
Total UPIIA PT:
364
Ib
N/A
Pr:
PT:
662
Ib
Holdom
P,:
1028
Ib Holdown
582
lb Ib
H.1down
470
It
NIA
PT:
644
It N/A
3rd Floor Wells
2nd Floor Walls
Lateral Force:
6000p
6000If
it
Force:
2750
pit
1st
Floor Walls
Tnb. Length:
1
H
Tnb. Length:
1
Lateral Force:
3750
pit
Less due to geo:
0
Ib
Less due to
0
ft
Tnb. Length:
7
It
:
i 00
-
geo:
pit
Less due to geo:
0
pit
Total WeII LengN:52.5
H
Total Wall Length:
52.5
ftp
:
1.00
Shod Well Length:
28
ft
Short Wall Length:
28
Total Wall Length:
52.5
H
Wall Height:
8
ft
F6 Depth: 1
a Wall Height:
8
ft
Shod Wal Length:
28
it
Roof DL:
20
psf
ft
Fir Depth: 1
H Wall Height:
a
ft
Tnb. Width:
10
ftFloor
Floor DL:
20
psf
DL:
10
pat
Wall Weight:
f5
psf
Tnb. Width:
10
ft
Tnb. Width:
6
R
DL factor.
0.53
Wall Weight:
15
psf
Wall Weight:
15
psf
Force Fs:
6000
Ib
DL factor:
0.53
DL factor.
0.53
mlevel,
Force total, Fr:
6000
Ib
F2:
2750
Ib
F,:
50
Ib
Shear level, Vs:
7f4
pit
Wall
Fr:
VT:
8750
Fr:
122
Ib
Total shear, VT:
114
pit
q
52
plf
pl
Wall
VI:
1
pit
Wall
Total O.T.M:
48000
H9b
VT:
Total O.T.M:
167
124000
pit
ft -lb
A
VT:
233 8
pit
q
Shod Wall O.T.M:
25800
ft'IbTotal
Short Wall O.T.M:
37333.333
H•Ib
O.T.M:
232750
Wit,
Shod Wall Mn:
125440
Wit,
Wall Ma:
25DBB0
fPib
Shod
Short Wall O.T.M:
53333.3333
ft -lb
Uplift ®level, Ps:
0
Ib
Strap
D
Shari Well Ma:
321440
Total UpliH Pr:
0
Ib
N/A
Px:
Pr:
d054
Ib
Hol:
582
lb Ib
H.1down
p
Ib
N/AIA
PT:
p
Ib
NIA
Project Name: 1 project #: Initials: Date: Sheet:
777
.cn sc*a
e
1- BTORV WORD SHEARWALL
LINE:
6
LINE:
C
Lateral Force:
2150
plf
Lateral Force:
2500
pit
Trib. Length:
1
ft
Trib. Length:
1
it
Less due to geometry:
0
Ib
Less due to geometry:
0
Ib
p:
1.00
p:
1.00
Total Wail Length:
14
ft
Total Wall Length:
8
ft
Short Wall Length:
14
ft
Short Wall Length:
4
ft
Wall Height:
8
ft
Wall Height:
8
it
Roof DL:
20
psf
Roof DL:
20
psf
Trib. Width:
2
ft
TO. Width:
6
it
Wall Weight:
20
psf
Wall Weight:
20
psf
DL factor:
0.60
01 factor.
0.60
Force
2150
Ib
Wall
Force:
2500
Ib
Wall
Shear, V:
154
plf
A
Shear, V:
313
plf
A
Total O.T.M:
17200
ft'Ib
Total O.T.M:
20000
ft'Ib
Short Wall O.T.M:
17200
ft'Ib
Short Wall O.T.M:
10000
ft'Ib
Short Wall Ma:
19600
ft'Ib
Strap
Short Wall Ma:
2240
ft'lb
Strap
Uplift:
389
Ib
_ NIA
Uplift:
2164
Ib
STHD10
LINE:
yx10(
LINEr
Lateral Force:
0
plf
Lateral Force:
0
plf
Tdb. Length:
0
ft
Trib. Length:
0
ft
Less due to geometry:
0
Ib
Less due to geometry:
0
Ib
p:
1.00
p:
1.00
Total Wall Length:
0
ft
Total Wall Length:
0
ft
Short Wall Length:
0
ft
Short Wall Length:
0
It
Wall Height:
0
ft
Wall Height:
0
ft
Roof DL:
0
psf
Roof DL:
0
psf
Trib. Width:
0
ft
Trib. Width:
0
ft
Wall Weight:
0
psf
Wall Weight:
0
psf
DL factor:
0.60
DL factor:
0.60
Force:
0
Ib
Wall
Force:
0
Ib
Wall
Shear, V:
#DIV/01
plf
A
Shear, V:
#DIV/01
plf
A
Total O.T.M:
0
ft'Ib
Total O.T.M:
0
ft96
Short Wall O.T.M:
0
ft'Ib
Short Wall O.T.M:
0
ft"Ib
Short Wall Ma:
0
ft'Ib
Strap
- Short Wall Ma:
0
ft'Ib
Strap
Uplift:
#DIV/01
Ib
NIA
Uplift:
#DIV/01
Ib
NIA
Project Name: Project #: Initials: Date: Sheet:
SEISMIC LATERAL ANALYSIS
Totals:
482
5,868
32,9
2006Infemaiional Building CodepecASCE
LOS
Diaphragm Design Forces (calculations per ASCE 7.05 Section 12.10.1.1)
h, wo. Ewl EFI Fa.
it 170 0 Po kips kips kips
9 17.1 17.1
56.0 326 25.0
9 158.0 482 13.8
32.9 13.8
F„ (ASD)
12.0
9,7
9.7
Equlvalenl Lafeal Fo¢e procedure
PROJECT NAME:
Temple View -18 unit
IE:
Occupancy Category:
1.00
II
R: 6.5
F.: 1.43
Seismic Design Category:
D
CI:
F.,: 2.15
Site Class:
DSDs:
Ss: 0.46.46 6
81: 0,162
0.4434 (Eq. 11.4-1 & 11.4-3)
k:
1.00
TL: 6.0
Sm: 0.2324E
( q 11.4-2 & 11.4-4)
sec.
T: 0.175 sec. (12.8.7)
Governs =>
C,= So,/(R/p:
0.068
(12.8-2)
Max C:= So,/(R/I)T:
0.205
(12.6-3) (T equal or less than TL )
2
Max Ca SD,(FL)/(R/I)T :
-
(12.8-4) (T greater than TL )
Min C,= 0.5S1/(R/1):
-
(12.8-6) (S,equal or greater then 0.6)
Min Ce
0.010
(12.8-5)
Seismic Base Shear (V) =C,W:
32.9 k
(12.8-1)
Vertical Distribution of Seismic Forces (calculations per ASCE 7.05 Section 12.8.3)
Level
h,
ft
W. -V h;x
kips
F•
Roof
18
kip -ft
170.0 3,060
kips
kips kips E(ASD)
3rd Floor
9
158,0 1,404
179
17.1 12.0 0.071 W
2nd Floor
9
156.0 1,404
7.9
25.0 17.5 0.035 W
7.9
32.9 23.0 0.035 W
Fp=0.41ESDSIrVw Or 0.1 W,,.
Fp=0.81ESO^
Fp,,,n=4o0SDsIE pit or 280 pit
and Diaphragm Anchorage (calculations per ASCE 7-05 Section 12.11)
(Ultimate)
out-o%plane Wall design forces ==>F,: 0.18 Wp
Totals:
482
5,868
32,9
Levelft
Roof
3rd Floor
2nd Floor
Diaphragm Design Forces (calculations per ASCE 7.05 Section 12.10.1.1)
h, wo. Ewl EFI Fa.
it 170 0 Po kips kips kips
9 17.1 17.1
56.0 326 25.0
9 158.0 482 13.8
32.9 13.8
F„ (ASD)
12.0
9,7
9.7
Fp=0.41ESDSIrVw Or 0.1 W,,.
Fp=0.81ESO^
Fp,,,n=4o0SDsIE pit or 280 pit
and Diaphragm Anchorage (calculations per ASCE 7-05 Section 12.11)
(Ultimate)
out-o%plane Wall design forces ==>F,: 0.18 Wp
(ASD)
0.13 Wp
anchorage to Ilexible diaphragm force =_> F,: 0.35 Wp
0.25 Wp
__> F,(min): 280 plf
200 pit
Project Name: Project #: nitials: Date: Sheet:
5E15MIC WEIGHT
ROOF OR FLOOR
TOTAL AREA (FT�2) 450❑
DEAD LOAD (PSF) 2S
LIVE / SNOW LOAD (PSF) 3S
% SNOW / LIVE LOAD (PSF) 209/
WEIGHT (K)
1 44.0
SEISMIC WEIGHT (K) : 1613.9
Project Name: Project #: Initials: Date: Sheet:
ZONE : ) S UNIT
LEVEL : ROOF
WALL
WALL TYPE
EXTERIOR
INTERIOR
TOTAL LENGTH (FT)
WALL HEIGHT (FT)
2S6
35
PARAPET (FT)
6
B
WALL (PSF)
❑
❑
20
10
WEIGHT (K)
20.5
5.4
ROOF OR FLOOR
TOTAL AREA (FT�2) 450❑
DEAD LOAD (PSF) 2S
LIVE / SNOW LOAD (PSF) 3S
% SNOW / LIVE LOAD (PSF) 209/
WEIGHT (K)
1 44.0
SEISMIC WEIGHT (K) : 1613.9
Project Name: Project #: Initials: Date: Sheet:
SEISMIC WEIGHT
ROOF OR FLOOR
TOTAL .AREA (FTS 2) 417S
DEAD LOAD (P5F) 25
LIVE / SNOW LOAD (P5F) ❑
SNOW/ LIVE LOAD (P9F) D%
WEIGHT (K)
104.4
SEISMIC WEIGHT (K) ; 149.9
ZONE: )_ g� UNIT
LEVEL : ST&=5
WALL
WALL TYPE
TOTAL LENGTH (FT)
EXTERIOR
INTERIOR
WALL HEIGHT (FT)
246
45
PARAPET (FT)
8
6
WALL (P5F)
❑
❑
40
1 E
WEIGHT (K)
39.7
5.9
ROOF OR FLOOR
TOTAL .AREA (FTS 2) 417S
DEAD LOAD (P5F) 25
LIVE / SNOW LOAD (P5F) ❑
SNOW/ LIVE LOAD (P9F) D%
WEIGHT (K)
104.4
SEISMIC WEIGHT (K) ; 149.9
G
SEISMIC LATERAL ANALYSIS
Mea Infemafipne/ auildnp Cotle perASCE ]-05
EquAmlenf Laferel Fo2e P�acedum
PROJECT NAME, Temple VleW_12unit
la:
1.00
R: 6.5
Fe: 1.43
Occupancy Category:
II
q: 0.02
F': 2.15
Seismic Design Category:
D
Ss: 0.466
Site Class:
D
SI: 0.162
Sos: 0.4434 (Eq. 11.4-1811.4-3)
k:
Sof 0.2324 (Eq. 11.4-2 811.4-4)
1.00
TL: 6.0 sec,
T: 0.175 sec. (12.8-7)
Governs=>
Cs Sos/(R/1):
0.068
(12.8-2)
Max C,= Sci/(R/I)T:
0,205
(12.8-3) (T equal or less than TL )
Max C,= SodTL)/(R/1)T':
-
(12.8-4) (T greater than TL )
Min C,= 0.551/(R/I):
-
(12.8-6) (Slequal or greater than 0.6)
Min Ce
0.010
(12.8-5)
Seismic Base Shear (V) =C,W:
23.4k
(12.8-1)
Vertical Distribution of Seismic Forces (calculations
per ASCE 7-05 Section 12.8.3)
Level
hz
ft
Wa w, hxk
F,
V. V, (ASD)
Roof
18
kips kiP•ft
123.0
kips
kips kips E (ASD)
3rd Floor
9
2,214
110.0 990
12.4
12.4 8.8 0.070 W
2nd Floor
9
110.0 990
5.5
5.5
17.9 12.5 0.035 W
23.4 16.4 0.035 W
Totals: 343 4,194 23.4
Diaphragm Design Forces (calculations per ASCE 7-05 Section 12.10.1,1)
h" Wpz
Level s EFS Fpr Fp, (ASD)
ff ki
Roof Pskips kips kips kips
18 123.0 123 12.4 12.4 8.8
3rd Floor 9 110.0 233 17.9 9.8
2nd Floor g 6.8
110.0 343 23.4 9.8 8.8
Fp=0.41aSosWw or 0.1 Ww
Fp=0.81e8osWw
Fpm,a=400Sosla pif of 280 plf
Forces and Diaphragm Anchorage (calculations per ASCE
(Ultimate) (ASD)
out -of -plane Wall design forces ==> Fp: 0.18 Wp 0,13V
P
anchorage to flexible diaphragm force ==> Fp: 0.35 Wp 0.25 Wp
__> Fp(min): 280 plf 200 pif
Project Name: Project #: nitials: Date: Sheet:
SEISMIC WEIGHT
ZONE:. Z UNIT
LEVEL : ROOF
WALL
3300
DEAD LOAD (PGF)
WALL TYPE
EXTERIOR
INTERIOR
TOTAL LENGTH (FT)
184
64
WALL HEIGHT (FT)
S
8
PARAPET (FT)
0
0
WALL (PSF)
20
1 ❑
WEIGHT (K)
ROOF OR FLOOR
14.7 3.4
TOTAL AREA CPT ^2)
3300
DEAD LOAD (PGF)
85
LIVE / SNOW LOAD (PSF)
35
SNOW / LIVE LOAD (PSF)
20/
WEIGHT (K) 105.6
SEISMIC WEIGHT 00 : 123.7
Project Name: Project #: Initials: Date: Sheet:
Cvt
SEISMIC WEIGHT
WEIGHT (K) 29.4 3.4
ROOF OR FLOOR
TOTAL AREA (FT�2) 305❑
DEAD LOAD (PSF) 2S
LIVE / SNOW LOAD (PSF) ❑
SNOW/ LIVE LOAD (PSF) ❑%
WEIGHT (K) 76.3
SEISMIC WEIGHT (K) : 109.1
Project Name: Project #: Initials: Date: Sheet:
ZONE : 1 2 UNIT
LEVEL : ST&2ND FLRS
WALL
WALL TYPE
EXTERIOR INTERIOR
TOTAL LENGTH (FT)
1S4
S4
WALL HEIGHT (FT)
0
0
PARAPET (FT)
0
0
WALL (PSF)
40
10
WEIGHT (K) 29.4 3.4
ROOF OR FLOOR
TOTAL AREA (FT�2) 305❑
DEAD LOAD (PSF) 2S
LIVE / SNOW LOAD (PSF) ❑
SNOW/ LIVE LOAD (PSF) ❑%
WEIGHT (K) 76.3
SEISMIC WEIGHT (K) : 109.1
Project Name: Project #: Initials: Date: Sheet:
3• STORY WOOD SIHEARWALL
LINE, I ends
3rd
Floor Walls
2nd Floor Walls
led Floor Walls
Lateral Force:
2500
pit
Lateral Force:
2060
pit
Lateral Force:
2060
pit
Tab. Length:
1
it
Tnb. Length:
1
ft
Tab. Length:
1
R
Less due to geo:
0
to
Lass due to geo:
0
pit
Less due to geo:
0
pit
p:
1.00
p:
1.00
p:
1.00
Total Wall Length:
15.5
R
Total Wall Length:
15.5
ft
Total Wall Length:
15.5
ft
Shod Wall Length:
15.5
R
Short Wall Length:
15.5
a
Short Wall Length:
15.5
it
Wall Height
e
It
Fir Depth:
1 ft Wall Height:
8
ft
Fir Depth:
1 ft Wall Height:
8
It
Roof DL
20
psi
Floor DL:
20
psi
Floor DL:
20
psi
Tdb. Width:
2
It
Tab. Width:
2
it
Tdb. Width:
2
it
Wall Weight
20
psf
Well Weight:
20
psi
Wan Weight:
20
psi
DL factor.
0.60
DL factor.
0.60
DL factor.
0.60
Force ilh level, Fa:
2500
to
Fr:
2060
Ib
F,:
2060 -
Ib
Force total, Fr:
25W
Ib
Fr:
4560
Ib
FT:
6620
Ib
Shear ®level, Va:
161
pit
Wall
V2:
133
pit
Wall
V,;
133
pit
Walt
Total shear, VT:
161
plf
A
VT:
294
pit
A
VT:
427
pit
B
Total O.T.M:
20000
ft'lb
Total O.T.M:
58980
ft -lb
Total O.T.M:
116500
fl -lb
Shod Wall O.T.M:
20000
Wit,
Shod Watl O.T.M:
55980
ft -lb
Shod Walt O.T.M:
116500
ft -fib
Shod Wall Ms:
24025
fPlb
Shod Wall Ma:
48050
firlb
Shod Well MR:
72075
it -lb
Uplift @level, Pa:
360
ib
Strap
P2;
1424
Ib
Holdown
P,:
2487
to
Holdown
Total Uplift, Pr:
360
Ib
NIA
PT:
1945
Ib
MSTC40
Pr:
4726
to
HTTS
LINE.
2 and 3
3rd
Floor Walls
2nd Floor Walls
1st Floor
Walls
Lateral Force:
4120
pit
Lateral Farre:
3380
pit
Lateral Force:
3400
pit
Tdb, Length:
i
It
Tab. Length:
1
ft
Trib. Length:
1
it
Less due to geo:
0
Ib
Less due to geo:
0
pit
Less due to geo:
0
pit
p:
1.00
p:
1.00
p:
1.00
Total Wall Length:
24.5
R
Total Wall Length:
24.5
It
Total Well Length:
24.5
R
Shod Wan Length:
24.5
R
Shod Wall Length:
24.5
ft
Shod WeII Length:
24.5
it
Wall Height
8
it
Fir Depth:
i It Wall Height:
8
R
Fir Depth:
1 It Wall Height
a
It
Roof DL:
20
psf
Floor DL:
20
psi
Floor DL
20
psi
Tdb. Width:
2
a
Tab. Width:
2
R
Tab. Width:
2
4
Wall Weight
15
psi
Wall Weight:
15
psi
Well Weight:
15
psi
DL factor.
0.6a
DL factor.
0.60
DL factor
0.60
Force iih level. Fa:
4120
Ib
F2:
3380
to
F,:
3400
Ib
Force total, FT:
4120
Ib
Fr:
7500
Ib
Fr:
10900
Ib
Shear@ level, Va:
168
pit
Weil
V2:
138
Pit
WaII
V,:
139
pit
WaII
Total shear, VT:
168
pit
A
VT:
306
pit
B
VT:
445
pit
C
Total O.T.M:
32960
A -lb
Total O.T.M:
97080
R'Ib
Total O.T.M:
191780
Wit,
Shod Wall O.T.M:
32960
With
Shod Wall O.T.M:
97080
ft'Ib
Shod Wall O.T.M:
191780
With
Shod Wall MR:
48020
ft -lb
Short Wall MR:
96040
ft -lb
Shod Wall MR:
144060
ft -lb
Uplift @level. Pa:
169
Ib
Strap
P2:
1273
Ib
Holdown
P,:
2383
Ib
Holdown
Total Uplift, P7:
169
Ib
NIA
PT:
1610
Ib
MSTC40
PT:
4300
Ib
HTTS
Project Name: 11 Project #: Initials: Date: Sheet:
.&,dAcv02
I iz w)l-� (i
3- STORY WOOD SHEARWALL
B
LINar A
3rd
Floor Wells
2nd Floor Walls
1st Floor Walls
3rd
Floor Walls
Lateral Force:
2nd Floor Wells
pif
let Floor Walls
2750
pit
Lateral Farce:
4300
plf
pif
Lateral Force:
2000
pif
R
Lateral Farce:
2000
Ph
H
Trill. Length:
1
it
ft
Trib. Length:
1
It
Ib
Tdb. Length.
1
it
pif
Less due to goo:
0
Ib
pif
Less due to goo:
0
pif
Less due to geo:
0
pif
IF :
1.00
1.00
IF :
1.00
37
If
p :
1.00
37
ft
Total Wall Length:
88.5
fl
It
Total Wall Length:
66.5
11
ft
Total Wall Length:
68.5
fl
If
Short Wall Length:
3
ft
ft
Short Well Len9ft.
3
0
ft
Short Well Length:
3
it
a
Wall Height
8
ft
Fir Depth: 1
ft Wall Height:
8
ft
Fir Depth: 1
ft Welt Height:
8
ft
pat
Roof DL:
20
psf
psf
Floor DL:
20
pat
R
Floor DL:
20
psf
ft
Trib. Width:
8
ft
ft
Trlb. Width:
6
It
psf
Trib. Width:
6
ft
psf
Wall Weight:
15
psf
pat
Wall Weight
15
psi
Wall Weight:
15
psf
DL factor.
0.53
0.53
DL factor.
0.53
6000
Ib
DL factor.
0.53
2750
to
Force ith level, Fa:
4300
Ib
Ib
Fa:
2000
Ib
Ib
F,:
2000
It
Ib
Force total, FT:
4300
to
Ib
FT:
6300
Ib
pif
FT:
8300
Ib
pif
shear @level. Vs:
65
pif
Wall
Va:
30
plf
Wall
V,:
30
pit
Wall
Total shear, VT:
65
pif
A
VT:
95
pit
A
VT:
125
pif
A
Total O.T.M:
34400
frib
(rib
Total O.T.M:
89100
Will
Total O.T.M:
161800
ft -lb
Short Wall O.T.M:
Short Wall O.T.M:
1551.8797 ft9b
Shod Wall MR:
Short Wali O.T.M:
2273.6842 RIb
Short Wall O.T.M:
2995
Wilt
Shod Well Me:
1080
Rib
Shod Well Ma:
2160
flit,
Strep
Shod Wall MR:
3240
Will
Holtlown
Uplift@level, Pa:
325
ib
Strap
Pa:
566
to
Holtlown
P,:
807
Ib
Holtlown
Total Uplift, PT:
325
Ib
NIA
PT:
374
Ib
NIA
PT:
423
Ib
NIA
LINE:
B
3rd
Floor Wells
2nd Floor Walls
1st Floor Walls
Lateral Force:
6000
pif
Lateral Force:
2750
pit
Lateral Force:
3750
pif
Trib. Length:
1
R
Trib. Length:
i
H
Trib. Length:
1
ft
Less due to geo:
0
Ib
Less due to goo:
0
pif
Less due to goo:
0
pif
p:
1.00
p:
1.00
p:
1.00
Total Wall Length:
37
If
Total Wall Length:
37
ft
Total Wall Length:
37
It
Short Wall Length:
28
ft
Shod Wall Length:
28
If
Shod Wall Length:
28
ft
Well Height:
8
ft
Fir Depth:
1 ft Wall Height:
8
a
Fir Depth:
1 ft Wall Height:
8
ft
Roof DL:
20
psf
Floor DL:
20
pat
Floor OL
10
psf
Trib. Width:
10
R
Trib. Witllh:
10
ft
Trib. Width:
6
ft
Well Weight:
15
psf
Wall Weight:
15
psf
Wall Weight
15
pat
DI -factor.
0.53
DL factor.
0.53
DL factor.
0.53
Force ith level, Fa:
6000
Ib
Fa:
2750
to
F,:
3750
Ib
Force total, FT:
6000
Ib
FT:
8750
Ib
FT:
12500
Ib
Shear@level, Va:
162
pif
Wall
Vs:
74
pif
Wall
V,:
101
pif
WaII
Total shear, VT:
162
plf
A
VT:
236
pit
A
VT:
330
pit
B
Total O.T.M:
48000
frlb
Total O.T.M:
124000
frib
Total O.T.M:
232750
(rib
Shod Wall O.T.M:
36324.324 fPlb
Shod Wall O.T.M:
52972.973 Who
Short Wall O.T.M:
75675.6757 frib
Shod Wall MR:
125440
ft -lb
Shod Wall MR:
250880
ft -lb
Short Well MR:
321440
ft -lb
Uplift @ level, Py
0
Ib
Strep
Pa:
495
It
Holtlown
P,:
1360
Ib
Holtlown
Total UPlift, PT:
0
Ib
NIA
PT:
0
Ib
NIA
PT:
0
Ib
NIA
Project Name: 11 Project #: Initials: Date: Sheet:
eRod&Ya]
WIND DISTR18UTION
LOCATIONI End zone - transverse
Wind Speed: 90
Roof Press (psf): 10.0 Ridge Ht: 36
Exposure: C
Well Press (psf): 17.3 Eave Ht: 25.5
Roof typs (Ratisloped): sloped
8.5 ft
LATERAL LDAD91
8.5 ft
Story heights:
Ht. of Force Story force Cumlative force (plf)
Roof 8.5 ft
@ 25.5 ft 179 pit 179 pit
2nd floor 8.5 ft
@ 17.0 ft 147 pit 326 plf
1 st floor 8.5 ft
@ 8.5 ft 147 pit 473 pit
LOCATION: End zone - longitudinal
Wind Speed: 90 Roof Press (psf): 10.0 Ridge Hl: 36
Exposure: C Wall Press (psi): 15.0 Eave Hl.: 25.5
Roof type (flat/sloped): sloped
LATERAL LDADSI
Story force
Story
heights:
Roof
8.5 ft
2nd floor
8.5 ft
l at floor
8.5 ft
Ht. of Force
Story force
@ 25.5 It
169 plf 169 pit
@ 17.0 ft
128 pit 296 pit
@ 8.5 ft
128 pit 424 pit
Project Name: Project #: Initials: Date: Sheet:
Mgt ,F 13A3
Address JOB TITLE Temple View
s City, State
Phone JOB NO.
CALM II dTCfl AV
offleF CHECKED BY
www.struware.corn
Code Search
I. Code: International Building Code 2006
II. Occupancy:
Occupancy Group = R Residential
III. Type of Construction:
Fire Rating:
Roof= 0.0 hr
Floor= 0.0 hr
IV. Live Loads:
Roof angle (0)
5.00 / 12 22.6 deg
Roof 0 to 200 sf:
19 psf
200 to 600 sft
218 - 0.019Area, but not less than 12 psf
over 600 sf:
12 psf
Floor
50 psf
Stairs & Exitways
100 psf
Balcony / Deck
50 psf
Mechanical
N/A
Partitions
15 psf
V. Wind Loads : ASCE 7 - 05
Importance Factor
1.00
Basic Wind speed
90 mph
Directionality (Kd)
0.85
Mean Roof Ht (h)
31.0 ft
Parapet ht above grd
0.0 ft
Exposure Category
C
Enclosure Classi£
Enclosed Building
Internal pressure
+/.0,18
Building length (L)
145.0 it
I
Least width (B)
35.0 ft
{
V(Z)
Kh easel
0.989
Kh case
0.989
Speedup
V{z}
Topographic Factor (Kz0
x(upwind] x(downwind)
Topography
Flat
HJ2
Hill Height (H)
0.0 ft H< 15ft;exp C
Lh HJ2 H
Half Hill Length (Lh)
0.0 ft .. Kzt=1.0
^. . .
Actual H/Lh =
0.00
Use H/Lh =
0.00
ESCARPMENT
Modified Lh =
0.0 ft
From top of crest: x=
0.0 ft
V(Z )
Bldgu /down wind?
P
downwind
Z
Speed-up
H/Lh= 0.00
K, = 0.000
V(Z) X(upwind) x(downwind)
x/Lh = 0.00
K2 = 0.000
H/2
z/Lh = 0.00
K3 = 1.000
Lh H/2 H
At Mean Roof Ht:
----
Kzt=(I+K,KzK3)A2=
1.000
2D RIDGE or 3D AXISYMMETRICAL HILL
11 Project #: I Initials: Date: Sheet:
Address JOB TITLE Temple View
t• City, State JOB NO. Phone SHEI
CALM 11 ATM RV
tel CHECKED BY
V. Wind Loads - MWFRS h<60' Low-rise Buildings) Enclosed/partialiV enclosed only
s-'
P1F-Px IcM-U
rakmUE
Transverse Direction
Kz=Kh=
Base pressure (qh) =
GCpi =
`4
Torsional loads are
25% of zones I -4.
6 See code for loading
diagram
19=DnM iron .�
PPS:ALLEL Ia�E t���FisID i>II'aC PION
rQGR 1^
Longitudinal Direction
0.99 (case 1) Edge Strip (a) 3.5 ft
17.4 psf End Zone (2a) 7.0 ft
+/-0.18 Zone 2 length = 17.5 ft
= 22.6 deg
2
-0.45
-0.27
-0.63
-0.69
-0.51
-0.87
3
-0.47
-0.29
-0.65
-0.37
-0.19
-0.55
4-0.41
5
-0.23
-0.59
-0.29
-0.11
-0.47
6
-0.45
-0.27
-0.63
-0.45
-0.27
-0.63
6
-0.45
-0.27
-0.63
-0.45
-0.27
-0.63
lE
0.77
0.95-6
j9
0.61
0.79
0.43
2E
-0.72
-0.54
-0.90
-1.07
-0.89
-1.25
3E
-0.65
-0.47
-0.83
-0.53
-0.35
-0.71
4E
-0.60
-0.42
-0.78
-0.43
-0.25
-0.61
Wind
2
-4.8
-II.I
-8.9
-15.2
3
-5.0
-11.3
-3.3
-9.6
4
-4.1
-10.4
-1.9
-8.2
5
-4.7
•I1.0
-4.7
-I 1.0
6
-4.7
-11.0
-4.7
-11.0
IE
16.6
10.3
13.8
7.5
2E
-9.4
-15.7
-15.5
-21.8
3E
-8.2
-14.4
-6.1
-12.4
4E
-7.3
.13.6
-4.4
-10.6
Windward roof overhangs:
11.9 psf (upward) add to windward
Parapet
roof pressure
Windward parapet:
0.0 psf (GCpn =+1.5)
Leeward parapet:
0.0 psf (GCpn =-1.0)
Horizontal114WFRS Simple Diaphra
m Pressures InsD
Transverse direction (normal
to L)
Interior Zone: Wall
16.6 psf
Roof
0.2 psf
End Zone: Wall
23.9 psf
Roof
-1.2 psf
w
ovmrownRnERxAlao
M.
TRANSVERSE ELEVATION
wnrowwx Mw
I.EEwA ROJF
VERTGAL
Project Name: Interior Zone: Wall 12.0 psf
Project #:
Initials:
Date:
Sheet:
End Zone: Wall 18.1 psf
LONGITUDINAL
rr
JOB TITLE Temple View
Address _
t. City, State
Phone JOB NO, SHEET NO,
-•I__ CALCULATED BY _
DATE
V. Wind Loads - Components & Cladding: Buildings h<60' & Alternate design 60'<h<90'
ca (
Kz= Khcasel)= 0.99
Base Kh ( h - GCpi = +/-0.18 NOTE: If tributary area is greater than
P (q)- 17.4 psf a= 3.5 It
Minimum parapet height at building perimeter = 3.0 ft 700sf, MWFRS pressure may be used.
Roof Angle= 22.6deg
Type of roof= Gable
Roof
Negative Zone ]
-1.08
-1.01
-
•0.95
-18.8
•18.8 psf
Du sr
-17.6
100 sf
20 sf
70 sf
Meg
-1.88
-1.53
-1.38
•32.8
psf
-17.1 ps
-18.3 psf
-17.4
Negative Zone 3
-2.78
-2.36
-2.18
psf
-48.5
-26.7 psf
-24.1 ps
-30.1 sf
P
-25.4
Positive All Zones
0.68
0.54
0.48
psf
11.9 sf
-41.2 psf
-38,0 sf
P
-45.3 psf
-39.6
P
10.0 psf
10.0 Pat
10.8 ps
10.0
Overhang Zone 2
Overhang Zone 3
•2.20
•3.70
-2.20
.2,86
-2.20
•38.4 sf
P
-38.4 psf
-35.4 ps
-38.4 psf
-38.4
•2.50
-645 psf
-49.9 psf
-43.6 ps
-58.2 ps
•46.8
Walls
GCp +/- GCpi
Surface Pressure (psf)
Area
Negative Zone 4
10 sf
100 sf
500 sf
10 sf
100 sf
500 sf
User input
50 sf
200
Negative Zone 5
-1.28
-1.58
-I.10
-1.23
•0.98
•0.98P
-22.3 psf
-19.2 sf
-17.Ips
-20.2 psf
sf
-18.31
Positive Zone 4 & 5
1.18
1.00
0.88
-27.5 psf
20.6
-21.4 psf
-17.1 ps
-23.2 psf
-19.5 I
psf
]7.5 sf
p
15.3ps
18.4osf
tF�..
Paranet
qp = 0.0 psf
CASE A = pressure towards building
CASE B =pressure away from building
Rooftop Structures & Equipment
Dist from mean roof height to centroid of Af = 10.0 It
Height of equipment (he) = 15.0 ft
Cross -Section Square
Directionality (Kd) 0.90
Width (D) 10.0 ft
Type of Surface N/A
Solid Parapet Pressure 10 sf
100 sf
500 sf
CASE A : Interior zone : 10.0 psf
10.0 psf
10.0 psf
Comer zone: 10.0 sf
CASE B : Interior zone : -10.0 psf
10.0 sf
-10.0
10.0 psf
Corner zone: -10.0 sf
psf
-10.0 sf
•10.0 psf
-10.0 psf
Gust Effect Factor (G) =
0.85
Base pressure (qz) =
21.8 Kit psf
Square (wind along dig onal)
Ct =
Cf =
1.01
Af =
10.0 sf
Adjustment Factor (Adj) =
1.90
F=gzGCfAfAdj=
16.8 Af
F=
168 lbs
h/D = 1.50
Square (wind normal to face)
Ct =
1.31
At =
10.0 sf
Adjustment Factor (Adj) =
1.900
F=%GCtAr Adj=
21.8 Af
F =
218 lbs
Project Name: Project #: nitials: Date: Sheet:
+- Address J09 TITLE Temple View
"
City, State
Phone JOB NO. SHEET NO.
CALCULATED BY
Location of Wind Pressure Zones
Monoslope roofs 10'< 0 s 30°
a
DATE
I I I I u
o Ilo ol (D�2 Q o
I I I I J I
I I I I
I I I
29, 1 \ 2
Z
0 > 7 degrees
0 > 7 degrees
Project Name: 11 Project #: Initials: Date: Sheet:
I
I
—1
la
I I
—
I
I I
co �? F-----r-L
0 5 7 degrees and
Monoslope roofs
Monoslope 5 3 degrees
30 <0 5 100
Monoslope roofs 10'< 0 s 30°
a
DATE
I I I I u
o Ilo ol (D�2 Q o
I I I I J I
I I I I
I I I
29, 1 \ 2
Z
0 > 7 degrees
0 > 7 degrees
Project Name: 11 Project #: Initials: Date: Sheet:
40
FOOTING & FOUNDATION
Soil Bearing Pressure: 1500 psf
EXTERIOR FOUNDATION
Total Load (plt): Foundation Width (ft)
2070 1.38
Exterior Foundation Requirements:
USE lft 6in WIDE loin THICK WITH (2) #4 BARS BOTTOM
EXTERIOR FOUNDATION
Load
Tributary
Roof.
60 psf
7 ft
Wall:
20 psf
30 ft
Floor:
75 psf
14 ft
Misc:
psf
ft
Total Load (plt): Foundation Width (ft)
2070 1.38
Exterior Foundation Requirements:
USE lft 6in WIDE loin THICK WITH (2) #4 BARS BOTTOM
EXTERIOR FOUNDATION
Exterior Foundation Requirements:
USE 211WIDE 10in THICK WITH (2) #4 BARS BOTTOM
INTERIOR FOOTINGS
Load
Tributary
Roof:
60 psf
7 ft
Wall:
20 psf
30 ft
Floor:
75 psf
14 ft
Misc:
120 psf
5 ft
Exterior Foundation Requirements:
USE 211WIDE 10in THICK WITH (2) #4 BARS BOTTOM
INTERIOR FOOTINGS
Interior Footing Requirements:
USE 2ft WIDE 10in THICK WITH (2) #4 BARS BOTTOM
SPOT FOOTING
Load
10 kip
Total Load (plf): Foundation Width (ft)
2670 1.78
Total Load (plf): Foundation Width (ft)
2880 1.92
Footing Area (fl"2) Footing Length / Width (ft)
6.67 2.58
Spot Footing Requirements:
USE 3ft- Din x 3ft-Oin WIDE 12in THICK WITH (5) #4 BARS BOTTOM BOTH WAYS
SPOT FOOTING
Load
Footing Area ( ft"2) Footing Length I Width (ft)
Project Name: Project #: Initials: Date: Sheet:
Load
Tributary
Roof:
60 psf
13 ft
Wall:
10 psf
30 ft
Floor:
75 psf
24 ft
Misc:
0 psf
0 ft
Interior Footing Requirements:
USE 2ft WIDE 10in THICK WITH (2) #4 BARS BOTTOM
SPOT FOOTING
Load
10 kip
Total Load (plf): Foundation Width (ft)
2670 1.78
Total Load (plf): Foundation Width (ft)
2880 1.92
Footing Area (fl"2) Footing Length / Width (ft)
6.67 2.58
Spot Footing Requirements:
USE 3ft- Din x 3ft-Oin WIDE 12in THICK WITH (5) #4 BARS BOTTOM BOTH WAYS
SPOT FOOTING
Load
Footing Area ( ft"2) Footing Length I Width (ft)
Project Name: Project #: Initials: Date: Sheet:
D
15 kip 10.00
3.16
Spot Footing Requirements:
USE 3ft- 61n x 3ft- Sin WIDE 121n THICK WITH (6) #4 BARS BOTTOM BOTH WAYS
SPOT FOOTING
Load Footing Area ( M2) Footing Length / Width (ft)
32 kip 21.33
4.62
Spot Footing Requirements:
SPOT FOOTING SHEET EXCEEDED !!III
SPOT FOOTING
Load Footing Area (ft"2) Footing Length / Width (ft)
20 kip 13.33
3.65
Spot Footing Requirements:
USE 4ft- Oin x Oft- Oin WIDE 12in THICK WITH (7) #4 BARS BOTTOM BOTH WAYS
SPOT FOOTING
Load Footing Area(ft"2) Footing Length/Width(ft)
32 kip 21.33
4.62
Spot Footing Requirements:
SPOT FOOTING SHEET EXCEEDED VIII
SPOT FOOTING
Load kip Footing Area (f"2) Footing Length / Width (ft)
0.00 0,00
Spot Fooling Requirements:
USE 1ft- 6in x 1ft- 6in WIDE 12in THICK WITH (2) #4 BARS BOTTOM BOTH WAYS
Sheet:
11 00331, 11 00332, 11 00333
Blue Water Days
State of Idaho
Fire Sprinkler Plans
DEPARTMENT OF INSURANCE
C.L. "BUTCH" OTTER 700 West State Street, 3rd Floor
Governor
P.O. Boz 83720
MONWio UL5 STATE: ZIP: 8 OI
Boise, Idaho 83720-0043
Za- 2Y^523a FAXNO: 20$- 524 - 2[19
Phone(208)334-4250
DATE PLAN RECEIVED: -7 — 31 • i 2 DATE PLAN REVIEWED: - 3- 1,L
FAX # (208)3344398
WH.LIAM W. DEAL
Director
MARK A. LARSON
State Fire Marshal
PLAN REVIEW FOR FIRE SPRNKLEER SYSTEMS
PROJECT:
B L 4 E W A-T�--R, :DA. -(s APA its r--\htT'S
STREET ADDRESS: S. 4 T 1e 1,A I. Rb' Sir" CITY Re-&SUP'64
FIRE PROTECTION CONTRACTOR: ., EM ST?,T£ T- t rZRI zTlal l 1
ADDRESS:
I I oS So N A 1q OM O
CITY:
MONWio UL5 STATE: ZIP: 8 OI
PHONE NO:
Za- 2Y^523a FAXNO: 20$- 524 - 2[19
SIGNATURE ON PLAN: " DATE ON PLAN: - l V - !2
DATE PLAN RECEIVED: -7 — 31 • i 2 DATE PLAN REVIEWED: - 3- 1,L
ITEM
NO.
DEFICIENCY NOTED
r
-M-k i Go tt G v '-D C.)AJ CA — u E
"41+C^: Rl-V 1Sel� YJ L.&4 /S -/i-aw N
NOTE:
SYSTEMS EXCEEDING 20 SPRINKLERS IN SIZE SHALL BE CONSTANTLY SUPERVISED AT A
CENTRAL LOCATION - I.F.C. 903A
NOTE:
IT IS ACKNOWLEDGED THAT AN UNAPPROVED BACKFLOW PREVENTER IS INSTALLED PER
THE DEMAND OF THE LOCAL WATER PURVEYER. DUE TO THE HIGH PRUPORTED FAILURE
RATE. STATE FIRE MARSHAL'S OFFICE, AND TTS PERSONNEL, DOES NOT APPROVE OF OR
TAKE ANY RESPONSIBHdTY FOR THE BACKFLOW DEVICE.
REVIEWED BY:
LDH Enterprises
PO Box 9
Fairfield, Idaho 83327
PLANS REVIEWER:
Mei Fletcher
Ph 208-764-2b77 Fax 208-764-2090
CC TO:
• - _
t� L1C3 RCS
Mark Larson
Idaho Surveying & Rating
File
A.H.J.
F va6- D Orr—
I APPROVED — If deficiencies noted
above are corrected and subject to a field
inspection.
El DISAPPROVED—Resubmit with items
noted * corrected.
❑ ADDITIONAL — Information requested
10-2005
Equal Opportunity Employer
State of Idaho
DEPARTMENT OF INSURANCE
C.L.'BUTCH" OTTER 700 West State Street, 3rd Floor
Governor P.O. Box 83720
Boise, Idaho 83720-0043
Phone (208)334-4250
FAX R (208)3344398
WILLIAM W. DEAL
Director
MARK A. LARSON
State Fire Marshal
PLAN REVIEW FOR FIRE SPRINKLER SYSTEMS
PROJECT: L Lte W -A TEEM p A wIbTITS
STREET ADDRESS: S • 'Z# Id, It. FS A stir S r CITY t15tCt
IM PROTECTION CONTRACTOR: C.13sr&Te F1 R,6 ICo 'c-rt4F4
ADDRESS: Ito-5 =004-A R0�0
_
CITY: =D A No r --A L IS STATE: l'D A," ZIP: 93AJot
PHONE NO: 20 e, -5Zy^6Z3a FAXNO: Zo8 SZy^ Znq
SIGNATURE ON PLAN: f tnt, DATE ON PLAN: 6 - j fz- r z
DATE PLAN RECEIVED: DATE PLAN REVIEWED:
Il'EM
NO. DEFICIENCY NOTED
1 -rmac' t'T'R4 -m IwE A STostA-CHEF a tN.INJ IRtZ t o k$
/a Arttt•tn '� 'T1iA DoET oT- t`4'r'I-tie= ct owS
s u- A R 054 &kl2p r-1
—
tQRc;Tg--r--n*-J
NOTE:
SYSTEMS EXCEEDING 20 SPRINELERS IN SIZE SHALL BE CONSTANTLY SUPERVISED AT A
CENTRAL LOCATION - LF.C. 903A
NOTE:
IT IS ACKNOWLEDGED THAT AN UNAPPROVED 13ACEFLOW PREVENT'ER IS INSTALLED PER
THE DEMAND OF THE LOCAL WATER PURVEYER. DUE TO THE HIGH PRUPORTED FAILURE
RATE, STATE FIRE MARSHAL'S OFFICE, AND ITS PERSONNEL, DOES NOT APPROVE OF OR
TAKE ANY RESPONSMnXrY FOR THE RACEFLOW DEVICE.
REVIEWED BY: LUH Enterprises
PO Box 9
Fairfield, Idaho 83327
PLANS REVIEWER:
Me] Fletcher
Ph 208-764-2337 Fax 208-764-2090
CC TO: Mark Larson
Idaho Surveying & Rating
' File�
A.H.J.
(ZcR,3u tzc, F 2E J7c7'r, -
❑ ,�O'7M If deficiencies noted
above are corrected and subject to a field
inspection.
121 DISAPPROVED -Resubmit with items
noted * corrected.
❑ Ai9)R40N* L - Information requested
10-2005
Equal Opportunity Employer
1100330
Blue Water Days, LLC — Photometric Plan
Routing:
Done NA
R" ❑ Joel Gray (Please review by Wednesday, March 28)
• p; d ndi a "ress P rave ou s ho+es , e u rr.en-'
YeVi s Ian s Sof l l s}a.nd
Please complete the following:
Done NA
❑ ❑
Review Plans
Enter Notes for the applicant under Submittals
Update status in the Approvals tab
Return building plan to Amanda Saurey
Thank you,
Amanda Saurey
i(-7
Plan Checklist for the 2009 International Building Code e
Project Name: ?:10F Wa-mz DA -YS Date:
USE AND OCCUPANCY ,
1. Classification as per Sections 302.1 & 303 thru 312 2
2. Incidental use areas see Table 508.2.5
3. Identify if mixed occupancy exists. Yes_ or Nok If no then skip #3 below.
Accessory Space (10% or under)
Nonseperated Mixed Occupancy as per Section 508.3.
Separated Mixed Occupancy as per Sec. 508.2.4_ Identify on plans Fire
arrier Walls and/or Horizontal Assemblies including the rating
If Assembly Occupancy exists, is it 750 sq. ft. or less as per Section 303.1 or
ss than 50 occupants as per Section 303.1
Covered Malls, see Section 402. Atriums see Section 404. Underground
Buildings see Section 405.Motor Vehicle Occupancies, see Section 406. 1 -2
Occupancies see Section 407. 1-3 Occupancies see Section 408. Motion
Picture Projection Rooms see Section 409. Stages and Platforms see
section 410. Special Amusement Buildings see Section 411. Aircraft Related
Occupancies see Section 412. Combustible Storage see Section 413.
Hazardous Materials see Section 414. H- Occupancies see Section 415.
Application of Flammable Finishes see Section 416. Drying Rooms see
Section 417. Organic Coatings see Section 418.
HEIGHT AND AREA
1. Area, First Floor, Second Floor, Third Floor
2. Area meets requirements as per Table 503 YesNIo
3. Height meets requirements as per Table 503. Yes ✓ No_
4. Buildings on same Lot? Yes/ No If no then skip #5 below.
,e Regulated as Separate or as one Building as per Section 503.1.2
6. Height modified as per Section 504. Yes_ No If yes, sprinklers are req'd.
7. Area modified as per Section 506. Yes_ Nofff yes use the area provided
below to calculate increase.
Total Area Allowed after Increase Area Shown on
Plans
8. Zero Lot Line Buildings see Section 705. For Mezzanines see Section 505.
Unlimited Area Buildings see Section 507.
TYPES OF CONSTRUCTION AND FIRE RESISTANCE.
1. Identify the Type of Construction as per Section 602_
,2�Check allowable material for Type I and II buildings as per Sect. 602.2
3. Table 601 - Identify Building Element Ratings _✓
4. Table 602 - Identify the Fire Resistance Ratings of Exterior Walls f%y,
Check Openings in Exterior Walls for compliance with Table 705.8.(If L fib,
sprinklered, see Section 705.8. 1)_
,71,' Projections meet requirements of Section 705.2
' Check for window vertical exposure from roof below as per Section
705.8.6_
Check that Parapets are not required as per Section 705.11
Are Firewalls used or required? Yes_ No If no, skip #10 below.
,1krCheck Firewalls for Structural Stability_ Fire Resistance Rating as per
Table 706.4_ Made of Noncombustible Materia ls(except Type V)_
Horizontal Continuity_ Vertical Continuity Connection to Exterior Walls as
per Section 706.5.1_ Extend to Horizontal Projecting Elements as per
Section 706.6 Openings (no windows) as per Section 706.8_ Check
that Penetrations meet requirements of Section 713_ Ducts and
it Transfer Openings in Firewall meet requirements of Section 705.10.
Are Fire Barriers used or required? (as required by table 508.4) Yes _ No
�If no skip # 12 below.
;1,,/Check Fire Barriers for structural stability Section 707.5.1._ Openings
limited to 25% of wall._ Maximum opening size of 120 sq. ft. (unless
sprinklered)_ Check that Penetrations meet the requirements of Section
707.7_ Ducts and Air Transfer Openings meet the requirements of Section
712 and 716.
41
/ _
Are Shaft Enclosures used or required? Yes_ No If no skip #14 below.
A4' haft Enclosures meet the requirements of Section 708_.
Cre Fire Partitions used or required? Yes_ No_ If no, skip #16 below.
heck Fire Partitions for Structural Stability and Continuity as per Section
709.4. Dwelling units that are sprinklered are allowed 1/2 hr. separations
versus 1 hr. Check that Penetrations meet the requirements of Section
713._
Ducts and Air Transfer Openings meet the requirements of Section 712 and
716._
17. Fire Rated Ceiling Panels meet requirements as per Section 711.3.1._✓
18. All Penetrations in Fire Resistive W IIs and Horizontal Assemblies meet the
requirements of Section 713.
19Fire Resistive Joint Systems meet the requirements of Section 714.
XDoors and Shutters in Fire Resistive Assemblies meet the requirements of
Table 715.4._
kireFire Doors are Self Closing._
re Windows or Glazing conform to Section 715.4 and Table 715.4._
and Smoke Dampers conform to Section 716._
Fire Blocking and Draft Stopping is provided as per Section 717_ (Draft
Stopping is not required at partition line in dwelling units with combined space
of less than 3000 Sq. Ft and not required if in sprinklered building with
sprinklered concealed spaces)
25. Wallancj Ceiling Finishes meet the requirements of Table 803.5 and Section
803._✓ /
26. Floor Finish meets requirements of Section 804.,/
FIRE PROTECTION SYSTEM
1. Is a Fire Protection System required for this building in order to meet area,
height etc. reuirements?
Yes —No _✓If no skip #2 below.
2. List the type of system that is required
3. Other requirements requiring Fire Protection Systems (check if needed):
Group A (As per Section 903.2.1)_
Group E (As per Section 903.2.2)_
Group F -1 (As per Section 903.2.3)_
Group H (As per Section 903.2.4)_
Group I (As per Section 903.2.5)_
Group M (As per Section 903.2.6)_
,,Group R (As per Section 903.2.7)_
Group S -1 (As per Section 903.2.8)_
Group S -2 (As per Section 903.2.9)_
All Buildings except R -3 and U (As per Section 903.2.10)_
Ducts conveying Hazardous Exhausts (As per Section 903.2.12.1)_
Commercial Cooking Operations (As per Section 903.2.12.2)_
As per Table 903.2.13_ /
4. If Sprinklers needed as identified in #3 list type of system required.
5. If Sprinklers required by any of the above, Are Monitors and Alarms provided
/as per Section903.4?
6 If an Alternative Automatic Fire Extinguishing System is identified, does it
meet the requirements of Section 904?_
7. Are Fire Alarms required as per Sections 907 or 908? Yes) No_ if no then
skip #8 below
;8. Do Alarms meet the requirements listed in Sections 907 or 908?
."Is smoke control required ?(as per Sections 402, 404, 405 or 410) Yes_
No_ If yes, see Sections 909.
/H Occupancies may require smoke and heat vents as per Sections 415.6 and
410.
MEANS OF EGRESS
1. Minimum height of T as per Section 1003.2. '/
2. Any protruding objects meet the requirements of Section 1003.3.
X The occupant load shown on plans._
sV The occupant load as per calculated by Table 1004.1.2. _
Occupant load posted in every assembly occupancy as per Section
1004.3._
6. Egress width is identified on plans. ✓
7. Egress width meets requirements as calculated per Table 1005.1.E
Multiple means of egress sized so that the loss of any one means of egress
shall not reduce the available egress capacity to less than 50% of total
required. �
.81*� Door encroachment does not reduce the required egress width to less than
50% required.
10. Means of egress is illuminated as per Section 1006. v----
,14"
,14" Illumination emergency power is shown for means of egress as per Section
1006.3. _
12. An enclosed exit stairway is shown. Yes_ No ✓ if no, skip # 13, # 14 and #
15 below._
JZa .Enclosed stairway has an area of refuge(as per Section 1007.6). _
.a4Area of refuge has 2 -way communications, instructions and is identified as
per Sections 1007.6.3,1007.6.4 and 1007.6.5. _
15. Door clear widths are a minimum of 32 " (accessible 34" min). Except as
allowed by exception of Section 1008.1.1. ,/
,W"boors swing in the direction of travel where serving 50 or more persons or in
a H occupancy. _
X%Specialty doors meet the requirements of 1008.1.4. _
18. All egress doyrs have a landing on both sides as per Sections 1008.1.4 and
1008.1.5.
19. Thresholds are identified as a maximum of high for swing doors, 3/4"
for sliding doors as per Section 1008.1.6. _✓
,20'space between two doors is less than 48 "(except R2 &R3 non Type A units).
?i1. Locks and latches meet requirements of 1008.1.9.3. _
,Panic hardware is shown at required locations (Section 1008.1.10).
23. Does a stairway exist.t�No If no, skip #24 thru #28.
.24'.- Stairway doors do not open over stairs. _
25. Stairways are a minimum of 44" wide(except where occupant load is 50 or
less or as per Section 1009.1).
26. Maximum riser is 7 inches and minimum tread is 11 inches.
27. A landing is provided at the top and bottom of each stairway.
28. Maximum vertical rise without a landing is 12'.
29. Handrails are identified that meet the requirements of Section 1009.12. ✓
30. Handrails return to wall, etc. or are continuous to next stair handrails
' ,r Elevation change of over 1/20 is designed as a ramp as per Section 1010_
,fie Exit signs are identified when over 2 doors are required for exiting. _
33. Exit signs are spaced no more than 100' apart or to the door. NID
34. 42" guardrails are shown whenever a walking surface is over 30" above
�� rade.✓
.�• Any roof mechanical equipment within 10' from edge has a guardrail shown.
36. Egress does not pass through intervening spaces unless the space is
accessory to the area served and the intervening space is not hazardous. _✓
,3�lf multiple tenant spaces exist, egress from any one does not pass through
another. _
38. Length of common egress travel does not surpass requirements as per
erection 1017. Z'
3g. Required egress aisle adjacent to tables shall comply with Section 1017.4.1.
40. Spaces with one means of egress meet the following maximum occupancy
loads:
a. Occupancy A, B, E,F,M & U - 50 occ.
b. Occupancy H -1, H -2, & H-3 - 3 occ.
C. Occupancy H -4, H -5, 1 -1, 1 -3, 1 -4, 10 occ. Zc'�TS
d. Occupancy S - 30 occ.
41. Where two or more exits are required, they are a minimum of 112 the
diagonal distance of the space served apart or where a space is served by
an automatic sprinkler system, the distance is 113. _
42. If a boiler or furnace room has over 500 sq. ft. with over 400,000 btu,s, two
xits must be provided. _
Refrigeration machinery rooms and refrigerated rooms over 1000 sq. ft. have
ttwo exits. Section1015.4 _
/ tage means of egress comply with Section 1015.6. _
Exit Access travel distance meets requirements of Table 1016.1. _
46. Exterior exit balconies constructed in accordance with Section 1016.2 have
100' added to their travel distance. ✓
A'i orridors are rated as per Table 1018.1. _
Corridor widths meet requirements of Section 1018.2. _
Corridor dead ends are less than 20' or 50' for sprinklered occupancies
RA'Corridor not used as plenum unless in a tenant space of less than 1000 sf.
51. The minimum number of exits r occupant load meets the following:
1 -500 requires 2 exits
501 -1000 requires 3 exits
More than 1000 requires 4 exits
_ 2'lBuildings with one exit meet the requirements of Section 1021 and
Table 1021.1.
,53-"Interior stairwells required as a means of egress meet the requirements of
Section 1022._
�54�Space under stairs is identified as 1 -hour rated. _
Exterior ramps or stairs are open on one side and have a minimum of 35 sq.
ft. of open space not less than 42" above any floor level. 1026.3 _
56. Exterior ramps and stairways are protected from the inside of building as per
Section 1026.6. Z�
57. Exterior balconies, stairways and ramps are over 10' from lot lines and other
/buildings on the Iot.1027.3 ✓
,58 Egress courts meet the requirements of Section 1027.5. _
Assembly occupancies meet the requirements of Section 1028. _
60. Window egress or betterice-provided in every sleeping room and any
abitable basement. ✓See Exc. 1029.1, 1&2
Vestibule is provided as per Section 502.4.7 of the International Energy
Conservation Code.
ACCESSIBILITY
1. An accessible route connects all accessible buildings, accessible facilities,
accessible elements, accessible sp#ces and the public right -of- way(except
as excepted by Section 1104).
2. In addition to the required accessible entrances, 50% of all public entrances
are accessible. _✓
3. Accessible parking is provided as per Table 1106.1.
10% of hospital out patient parking is accessible and 20% of rehab or physical
therapy. _
5. Van spaces are provided.(one out of six and any portion) ✓
6. Accessible parking is provided on shortest route fr9m accessible parking to
the accessible building entrance. Sec 1106.6 _✓
Group I occupancies meet accessibility requirements as set forth in Section
1107.5. _
Group R -1 occupancies meet the requirements of Section 1107.6 and Table
1107.6.1.1. _
9. Where 4 or more apartment units, one level town homes or condos are
located in one structure, all units are designed as Type B units as per ICC
ANSI 117.1 unless on a upper level without elevator service. _✓
10. Where more than 20 apartment unit, one level town homes or condos are
located in a project, 2% but not less than on are designed as Type A units
as per ICC /ANSI 117.1_✓.
Wheelchair spaces (and companion seat as per Section 110 .2.5) are
provided in Assembly Occupancies as per Table 1108.2.2.1. _
Assistive listening systems are provided in Assembly occupancies where
audible communications are integral to the use of the space. _
ZAny Assembly occupancy performance area has an accessible route as per
ection 1108.2.8. _
Any dining area in an Assembly Occupancy is fully accessible. _
;e Self service storage facilities shall provide accessible spaces as per Section
1108.3. _
)eToilet and bathing facilities are accessible(unless in a private office)as per
Section 1109.2. _
Unisex toilets and bathing rooms are supplied as per Section 1109.2.1. _
Where sinks are provided, 5 %, but not less than 1 is accessible. _
19 Where a kitchen is provided, it is accessible(unless in Type B dwelling).
Storage cabinets, lockers, etc. one of each type is accessible Sec 1109.8.
INTERIOR ENVIROMENT AND ENERGY CONSERVATION
1. Attic ventilation exists that is 1 /150 of the floor space or 1/300 with vapor
barrier. Sec. 1203.2_✓
2. 50% of the attic ventilation is 3 ft. above eaves. ✓
_
,3f Crawl space ventilation complies with Section 1203.3.
4. Natural ventilation (windows, doors, etc.) is a min. of 4% of floor space.
5. Interior spaces that do not have opensq gs directly to outside meet
requirements of Section 1203.4.1. ✓
6. Bathrooms containing bathtubs, showers or spas are mechanically vented.✓
7. Natural or Artificial light is provided that meets the rqmts of Section 1205.
Courts shall meet the requirements of Section 1206.3. _
9. Dwellings party walls and floors meet sound rqmts of Section 1207.
10. All habitable�oms shall be a minimum of 7' wide, and a minimum of 70 sq.
ft. in area.
11. Dwelling units(except efficient units) have one habitable room of 120 sq. ft. ✓
12. All ceilings are a minimum of 7'6" with no more than 1/3 at 7'0". ✓
13. Attics and 9_,-te1Ts have access openings as per Section 1209. ✓
14. An energy review has been submitted that mets the requirements of the
International Energy conservation code.
EXTERIOR WALLS AND ROOFS
1. Exterior Wall Vapor retarder provided unless another apRwoved means to
avoid condensation and leakage has been provided. ✓ /
2. Water resistant barrier shown on sheathing as per Chapter 14.
3. Masonry vender is flashed at bottom and has weep holes as per Section
1405.3.2. ✓
4./Masonry veneer shall be mechanically attached as per Section 1405.5.
,Ff Stone Veneer is anchored as per Section 1405. . _6
6. Sidings shall be applied as per Section 1405.:
7. Fire separatioy istance for combustible veneers(siding) meet that of Table
1406.2.1.2. ✓ /
8. Balconies that protrude shall meet the requirement of Table 601 for floors_✓
Metal Composite Materials(MCM) shall meet the requirements of Section
1407.
10. Roof coverings meet the requirements of Table 1505.1. ✓
11. Double underlayment is providedin asphalt roofs with minimum slope of 2:12
up to and including a 4:12 slope. _✓
12. An ice dam membrane (one continuous sheet or two sheet cemented
together) for all asphalt roofs is pr vided from the roof edge to 24" inside of
the inside of the exterior wall. _✓
1 ,/Drip edge metal is provided along all roof edge.
,/Drip
roofs meet the requirements of Section 1507.4. _
uilt -up roofs meet the requirements of Section 1507.10. _
single Ply Plastic Roofing meet rqmts of Section 1507.12/13
0y - QII other roofing types meet the requirements of Section 1507. _
Buildings with roof drains are designed and sized as per UPC 1105.0.
STRUCTURAL DESIGN AND SPECIAL INSPECTIONS
1. Structural Use Group (as per Table 1604.5)��l'��
2. Structural documents for light frame wood b iildings as per Chapter 23
include floor, roof and live loads, ground snow load, basic wind speed, wind
exposure, seismic design category and site class. ✓
3. All plans except as described in #1 above shall include the following:
a. Floor live load including any reductions.
b. Roof live load as per Section 1607.11.
c. Roof Snow load, including the flat roof snow load, the snow exposure
factor, the snow load importance factor and the thermal factor.
d. Wind design data, including basic wind speed, wind importance factor
with building category, wind exposure, applicable internal pressure
coefficient and the design wind pressure used for the design of
components and cladding.
e. Earthquake design data including seismic importance factor, seismic
use group, mapped spectral response accelerations, site class, spectral
response coefficients, seismic design category, basic seismic - force -
resisting systems, design base shear, seismic response coefficients,
response modification factors and the analysis procedure used.
Flood zone is identified(if in flood zone see Section 1603.1.7) _
�8 Design of floor live loads in access of 50 lbs per sq. ft. also identify that signs
must be posted as per Section 1603. _
6. Structural design calculations meeting the requirements of chapter 16 have
been provided. _✓
Special inspections are identified for welding._
Special inspections are identified for high strength bolting.
9. Special inspections are identifieq for concrete construction except as
oxcluded by Section 1704.4.jNAb �iz Gam `�p,n
1ASpecialinspection are identified for masonry as per Section 1704.5.
y Special inspections are identified for fills greater than 12" deep where—a load
applied. _
pecial inspections are identified for all pier and pile foundations.
pecial inspections are identified for sprayed on fire resistance applications.
}Special inspections are identified for smoke control systems. _
Quality assurance plan for seismic resistance is provided (except for design
,,fight frame as per chapter 2308 or reinforced masonry less than 25 feet high)
Special inspections are provided for seismic force resisting systems. _
L7'Structural observations as per Section 1709 are identified for structures in
Seismic Use Groups II or III. _
optj�,p 18. Truss Details provided or noted to be provided prior to frame inspection.
SOILS AND FOUNDATIONS
1. Allowable soil foundation bearing pressure (as per Table 1806.2). ✓
2. A soil investigation is required per the requirements of Section 1803. where
questionable soils such as fill materials, organic soils, clays or questionable
rock strata exist. Do any of these conditions exist? Yes_ - No✓f yes, are
the necessary soil reports provided? Yes—No — No_
3. Grading is a minimum of 2% for concrete or asphalt surfaces or 5% for
natural surfaces. _✓ II
4. Information provided as per Section 1804.5 for any structural fill. LA
5. Footings (except for 1 story category 1 buildings no bigger than 400 sq. ft.)
,are 36" below grade for frost protection. ✓
R- Buildings on or adjacent to greater than 3/1 slopes meet requirements of
Section 1808.7. _
7. Top of foundation is a minimum of 12" above the adjacent street gutter
(unless a drainage path is identified and approved by the building official). ✓
8. Footings desi ned so that the allowable bearing capacity of the soil is not
exceeded.
9. Foundation meets the rqmnts of Section 1805.5 and Tables 1805.5 _✓
W -Except for Group R and U occupancies of light framed construction of
seismic design D and less than 3 stories in height, concrete is a minimum of
3000 p.s.i..
Retaining walls are designed with a lateral sliding and overturning factor of
safety of 1.5. _
Foundation drainage system or waterproofing (Section 1805) is provided
where water table warrants. _
13. Damproofing shown under slabs as per Section 1805.2.1.
14. Damproofing shown for foundation walls. _✓
15. jftlinimum of 4" of gravel is shown under all slabs.
Foundation drain is installed (except in well- drained gravel areas) as per
Section 1805.4.2
CONCRETE and MASONRY
1. Construction documents show compressive strength of concrete, strenn th or
ment. ✓
grade of reinforcement and the size and location of reinforce
2. Structures assigned to Seismic Design Category D contain a statement
identifying if slab -on -grade is designed as a structural diaphragm. ""�
3. Masonry construction documents identify size, grade, type and location of
.411inforcement, anchors and wall ties as per Section 2113.3. _✓
asonry fireplaces have minimum 12" thick footings that are 6" wider than
masonry. Sec 2113.2_
n00
1/Truss drawings identify requirements as per Section 2303.4.
/1. Joist layout plans are provided. Engineered products have computer layout.
3. Floor and roof sheathing meets requirements of Section 2304.7. ✓
4. Connections and fastening meet the requirements of Table 2304.9.1. r�
5. Fasteners in preservative treated wood are hot - dipped zinc coated
galvanized steel, stainless steel, silicon bronze or copper.
6. Wood framing members above foundations are 8" (min.) abgare soil.
7. Shear wall design meets requirements of Section 2305. _✓
GLAZING
Ai Glazing in pool, sauna, hot tub, steam room, bathtub or shower enclosures
(unless over 60" above standing surface) is safety glazing as per Section
2406.4. Within within 24" of door (unless over 60" above standing surface) is safety
glazing as per Section 2406.4. _
,3" -'Glazing greater than 9 sq. ft., bottom below 18 ", top above "and 36" from
,,walking surface is safety glazing as per Section 2406.4. _
lazing in guards and rails is safety glazing as per Section 2407. _
lazing next to stairways, landings and ramps (unless over 60" above
standing surface) is safety glazing as per Section 2406. _
MISC.
I. Number of plumbing fixtures shall meet the requirements of Table 2902.1. _---�
2 -'separate toilet facilities are provided for spaces with 16 or more employees,
or combination of employees and customers (except for mercantile
occupancy with occupancy of 50 or less). _
Z3 Public toilet facilities are provided as per Section 2902.3.
ft! Elevators meet the requirements of Chapter 30.
Kr Pedestrian walkways meet the requirements of Section 3104. _
fa! wnings and canopies meet the requirements of Section 3105. _
rT Marquees meet the requirements of Section 3106.
,Swimming pool enclosures and safety devices mee_t the requirements of
Section 3109. _
.9'- Protection for pedestrians during construction meets the requirements of
-Section 3306.
Existing structures meet the requirements of Chapter 34. _
°q oexnuq°
CITY o v P.O Box 280
35 North Iat East
o ° REXBURG Rexburg, Idaho 83440
.1
Fa"tui°'
A.Mm's Phone (208) 359-3020
menty Community
Review Action Fax(208)359-3022
April 2, 2012
Permit Number: 11 00331
Project Name: FOUNDATION ONLY - Blue Water Days Bld #1 - 21 Plex
Project Type: Multi Family Residential
Review Item
Actions Required for Approval
Approved
Building Department Review
Electrical Circuits Review
No electrical plan was submitted -therefore
03/22/2012
make sure that all wiring meets the 2008 NEC -
same electrical contractor as University
Gateway.
Electrical Service Review
No electrical plan was submitted -same as the
03/22/2012
University Gateway -make sure that the service
wiring meets the 2008 NEC.
Building Code Fire Compliance Review
04/02/2012
Building Type Complianceh.®e-
CXr \
\
04/02/2012
Height and Area Review
IP%
04/02/2012
Accessibility Review
P\AVM
04/02/2012
Energy Conservation Compliance Review
04/02/2012
Interior Environment
04/02/2012
Structural Review
Provide truss details before or at framing
04/02/2012
inspection.
Complies with approved Site Plan Review
04/02/2012
Exiting Review 04/02/2012
Mechanical Review 04/02/2012
Plumbing Storm Drain Review
Plumbing Potable Water Review
Water and Sewer Service
Plumbing Sewer Drain Review
1100330
Blue Water Days, LLC
Routing:
Done NA
❑ ❑ Dale Pickering (Please review by Thursday, April 4)
Please complete the following:
Done NA
.l' ❑ Review Plans
L0 ❑ Red Line Notes? (Amanda will transfer red lines to all copies)
❑ Enter Notes for the applicant under Submittals
❑ Update status in the Approvals tab
❑ ❑ Return building plan to Amanda Saurey
Thank you,
Amanda Saurey
Date: November 16, 2011
Project: Blue Water Days LLC
Issue: Snow Removal Development Agreement
It is our understanding that the proposed site plan for the Blue Water Days LLC Apartments
located on South 4'e West in Rexburg, Idaho meets the spacial requirements of 10% of the
parking areas reserved for snow storage. If the entire required area of reserved space is not
accessible or useable due to parked vehicles or other obstructions which we the owners/managers
have control, we will arrange at our cost to have the snow removed from the site in order to
provide the required number of parking spaces.
Signed: 0�4
Title:
Accepted by the City of Rexburg
Signed:
Title:
ASPEN ENGINEERING. INC.
10727 N YELLOWSTONE HWY.
IDAHO FALLS, IDAHO 83401
t_ 208-542-1911
PROJECT NAME: Blue Water Days - 4th West
PROJECT #: 2011.011 Input
CLIENT: Jared Sommer Result
DATE: 3/30/2012
STORMWATER CALCULATIONS -100 year storm
PRE DEVELOP
SITE AREA = 73204 Square Feet
C VALUE =
0 Sq. Ft. - Hard Surface
0 Building
0 Landscaping
83204 Unimproved
COMPOSITE C
Tc = (minutes)
38.77 tc=c(LnsA-.5)A0.467
i (10)* =
2.18 in/hour
i (100)* =
3.51 in/hour
Qp10 = C*i10*A
1.25 CFS
Opt 00 = Ci*100*A
2.01 CFS
POST DEVELOP
C CHANGES 37207 Sq. Ft. Hard Surface
20775 Building
15222 Landscaping
COMPOSITE C
Tc = (minutes)
Qp10 = C*i10*A
Qp100 = Ci*100*A
1.68 Acres
C VALUE WEIGHTED C
0.90
0
0.95
0
0.15
0
0.30
24961.2
Rock Dimension
0.34
L (length) = 210 feet S (slope) _
c = 0.83 feet,1.44 meters
n= 0.02 smooth pavements
0.30 Poor grass/bare sod
0.40 Average grass
0.80 Dense grass
C VALUE WEIGHTED C
0.90 33486.3
0.95 19736.25
0.15 2283.3
0.76
4.04 tc=0.0078(LA0.77/S0.385) length = 210 feet slope=
2.78 CFS
4.47 CFS (EQUALS PEAK RUNOFF = REQUIRED F.D. CAPACITY)
FRENCH DRAINS
#1
Barrel depth
12
Barrel diam.
4
Rock Dimension
15
Btm soil perm.
0.020
feet
feet
feet
fUmin. Coarse sand and Gravel+
PROVIDED STORAGE VOLUME
Barrel 150.80 cf
Rock 849.73 cf
Total 1000.53 cf
0 feet/feet
0.02 feeUfeet
#2
Barrel depth
8
feet
Barrel diam.
4
feet
Rock Dimension
10
feet
Btm soil perm.
0.020
ft/min. Coarse sand and Gravel+
PROVIDED STORAGE VOLUME
Barrel 100.53 cf
Rock 233.16 cf
Total 333.69 cf
TOTAL FRENCH DRAIN STORAGE CAPACITY 1334.22 c.f.
WEIGHTED DEPTH OF PRECIPITATION OVER ENTIRE SITE
0.29 inches (Volume of runoff w/o percolation)
In other words, it can rain 0.29 inches and the french
drains will hold the entire runoff volume without any
percolation
DISSIPATION CAPACITY (soil perm. X btm. area)
6.50 cf/min Greater than Required -OK
From IDF Curve generated from NOAA Atlas 2 data and NOAA Spreadsheet
+ Table 4.1 "Typical Values of Permeability Coefficients" - Braja M. Das,
Principles of Geotechnical Engineering, 2nd Ed.
UNWEIGHTED DEPTH OF PRECIP OVER ENTIRE SITE
0.22 inches
z -x-
N
v
Y -
5 0.50
0.00
5 10 15 30 1 2 3 6 12 24
Duration in minutes and hours
Intensity -Duration -Frequency - Rexburg, Idaho
Intensity (inches per hour)
Duration
2
5
10 25
50
100
--------------------------------------------------------------------
5
1.31
1.84
2.18 2.66
3.06
3.51
10
1.02
1.43
1.69 2.06
2.38
2.72
15
0.86
1.21
1.43 1.74
2.01
2.30
30
0.59
0.84
0.99 1.21
1.39
1.59
1
0.38
0.53
0.63 0.76
0.88
1.01
2
0.23
0.31
0.37 0.45
0.52
0.58
3
0.18
0.23
0.28 0.34
0.39
0.43
6
0.12
0.15
0.18 0.22
0.25
0.27
12
0.08
0.10
0.11 0.14
0.16
0.18
24
0.05
0.06
0.07 0.08
0.10
0.11
z -x-
N
v
Y -
5 0.50
0.00
5 10 15 30 1 2 3 6 12 24
Duration in minutes and hours