Loading...
HomeMy WebLinkAboutRESCHECK - 17-00438 - 935 Pine Brook Ln - New SFRREScheck Software Version 4.6.2 Compliance Certificate Project Humphreys Homes Energy Code:2012 IECC Location:Idaho Falls, Idaho Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:3,827 ft2 Glazing Area 14% Climate Zone:6 (7918 HDD) Permit Date: Construction Site:Owner/Agent: Castlerock Homes Designer/Contractor: COMFORT AIR DESIGN DBA WIEMER HEATING COMFORT AIR DESIGN DBA WIEMER HEATING IDAHO FALLS, ID 208-523-3848 Permit Number: Compliance: Passes using UA trade-off 0.6% Better Than Code Maximum UA:331 Your UA:329 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Wall 1: Wood Frame, 16" o.c.428 21.0 0.0 0.057 23 Window 1: Vinyl Frame:Double Pane with Low-E 20 0.320 6 Wall 2: Wood Frame, 16" o.c.576 21.0 0.0 0.057 25 Window 1: Vinyl Frame:Double Pane with Low-E 136 0.320 44 Wall 3: Wood Frame, 16" o.c.511 21.0 0.0 0.057 28 Window 1: Vinyl Frame:Double Pane with Low-E 15 0.320 5 Wall 4: Wood Frame, 16" o.c.549 21.0 0.0 0.057 25 Door 1: Solid 42 0.140 6 Window 1: Vinyl Frame:Double Pane with Low-E 61 0.320 20 Basement Wall 1: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' 403 19.0 0.0 0.045 17 Window 1: Vinyl Frame:Double Pane with Low-E 16 0.320 5 Basement Wall 2: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' 486 19.0 0.0 0.045 20 Project Title: Humphreys Homes Data filename: C:\Users\User\AppData\Local\Check\REScheck\Humphreys Homes.rck Page 1 of 2 08/03/17Report date: Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Window 1: Vinyl Frame:Double Pane with Low-E 32 0.320 10 Basement Wall 3: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' 403 19.0 0.0 0.045 18 Basement Wall 4: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' 486 19.0 0.0 0.045 21 Window 1: Vinyl Frame:Double Pane with Low-E 16 0.320 5 Ceiling 1: Flat Ceiling or Scissor Truss 1,953 50.0 0.0 0.026 51 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Notes: Job Number: New Humphreys Home NOTICE: THIS IS THE PROPERTY OF0 COMFORT AIR DESIGN. THIS REPORT CAN BE USED BY GENERAL CONTRACTOR FOR THE PURPOSE OF OBTAINING A PERMIT. ALL USE BY 3RD PARTY FOR USE IN INSTALLING, RUGH-IN OR FINAL INSPECTION IS STRICTLY PROHIBITED WITHOUT WRITTEN PERMISSION. INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Project Title: Humphreys Homes Data filename: C:\Users\User\AppData\Local\Check\REScheck\Humphreys Homes.rck Page 2 of 2 08/03/17Report date: 2012 IECC Energy Efficiency Certificate Insulation Rating R-Value 21.00Above-Grade Wall 19.00Below-Grade Wall 0.00Floor 50.00Ceiling / Roof _______Ductwork (unconditioned spaces): Glass & Door Rating SHGCU-Factor 0.32Window 0.14Door Heating & Cooling Equipment Efficiency _______Heating System:_________________________ _______Cooling System:_________________________ _______Water Heater:___________________________ Name:Date: Comments