HomeMy WebLinkAboutRESCHECK - 17-00438 - 935 Pine Brook Ln - New SFRREScheck Software Version 4.6.2
Compliance Certificate
Project Humphreys Homes
Energy Code:2012 IECC
Location:Idaho Falls, Idaho
Construction Type:Single-family
Project Type:New Construction
Conditioned Floor Area:3,827 ft2
Glazing Area 14%
Climate Zone:6 (7918 HDD)
Permit Date:
Construction Site:Owner/Agent:
Castlerock Homes
Designer/Contractor:
COMFORT AIR DESIGN DBA WIEMER
HEATING
COMFORT AIR DESIGN DBA WIEMER
HEATING
IDAHO FALLS, ID
208-523-3848
Permit Number:
Compliance: Passes using UA trade-off
0.6% Better Than Code Maximum UA:331 Your UA:329
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Wall 1: Wood Frame, 16" o.c.428 21.0 0.0 0.057 23
Window 1: Vinyl Frame:Double Pane with Low-E 20 0.320 6
Wall 2: Wood Frame, 16" o.c.576 21.0 0.0 0.057 25
Window 1: Vinyl Frame:Double Pane with Low-E 136 0.320 44
Wall 3: Wood Frame, 16" o.c.511 21.0 0.0 0.057 28
Window 1: Vinyl Frame:Double Pane with Low-E 15 0.320 5
Wall 4: Wood Frame, 16" o.c.549 21.0 0.0 0.057 25
Door 1: Solid 42 0.140 6
Window 1: Vinyl Frame:Double Pane with Low-E 61 0.320 20
Basement Wall 1: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 7.5'
Insulation depth: 9.0'
403 19.0 0.0 0.045 17
Window 1: Vinyl Frame:Double Pane with Low-E 16 0.320 5
Basement Wall 2: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 7.5'
Insulation depth: 9.0'
486 19.0 0.0 0.045 20
Project Title: Humphreys Homes
Data filename: C:\Users\User\AppData\Local\Check\REScheck\Humphreys Homes.rck Page 1 of 2
08/03/17Report date:
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Window 1: Vinyl Frame:Double Pane with Low-E 32 0.320 10
Basement Wall 3: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 7.5'
Insulation depth: 9.0'
403 19.0 0.0 0.045 18
Basement Wall 4: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 7.5'
Insulation depth: 9.0'
486 19.0 0.0 0.045 21
Window 1: Vinyl Frame:Double Pane with Low-E 16 0.320 5
Ceiling 1: Flat Ceiling or Scissor Truss 1,953 50.0 0.0 0.026 51
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in
REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Notes:
Job Number: New Humphreys Home
NOTICE: THIS IS THE PROPERTY OF0 COMFORT AIR DESIGN. THIS REPORT CAN BE USED BY GENERAL CONTRACTOR
FOR THE PURPOSE OF OBTAINING A PERMIT. ALL USE BY 3RD PARTY FOR USE IN INSTALLING, RUGH-IN OR FINAL
INSPECTION IS STRICTLY PROHIBITED WITHOUT WRITTEN PERMISSION.
INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE
VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID.
Project Title: Humphreys Homes
Data filename: C:\Users\User\AppData\Local\Check\REScheck\Humphreys Homes.rck Page 2 of 2
08/03/17Report date:
2012 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
21.00Above-Grade Wall
19.00Below-Grade Wall
0.00Floor
50.00Ceiling / Roof
_______Ductwork (unconditioned spaces):
Glass & Door Rating SHGCU-Factor
0.32Window
0.14Door
Heating & Cooling Equipment Efficiency
_______Heating System:_________________________
_______Cooling System:_________________________
_______Water Heater:___________________________
Name:Date: