Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2014 - Duct System Summary
Duct System Summary Job: 51259 Date: Jan 05, 2014 Entire House By: Steve Dick N.n.1 High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhlgagmail.com Project Information For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.70 in H2O 0.29 in H2O 0.41 in H2O 0.23/0.18 in H2O 0.092 in/100ft 741 cfm 445 ft Supply Branch Detail Table Cooling 0.70 in H2O 0.29 in H2O 0.41 in H2O 0.23/0.18 in H2O 0.092 in/100ft 741 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Room10 c 1886 75 101 0.119 6.0 0x0 ShMt 18.0 175.0 st1 Room11 h 2206 54 32 0.098 6.0 0x0 ShMt 35.5 200.0 an Room12 h 1392 34 28 0.092 6.0 0x0 ShMt 29.5 220.0 st1C Room13 c 1675 69 90 0.130 6.0 0x0 ShMt 32.5 145.0 stl Room13-A c 1675 69 90 0.095 6.0 0x0 ShMt 41.5 200.0 St1B Room3 h 691 17 4 0.146 6.0 0x0 ShMt 13.0 145.0 stl Room4 C 1301 53 70 0.108 6.0 0x0 ShMt 32.5 180.0 stl Room4-A C 1301 53 70 0.103 6.0 0x0 ShMt 33.0 190.0 st1A Rooms c 1611 67 87 0.117 6.0 0x0 ShMt 31.0 165.0 SO Room5-A c 1611 67 87 0.094 6.0 0x0 ShMt 44.5 200.0 st1A Room6 h 3140 77 37 0.099 6.0 0x0 ShMt 62.1 170.0 st2 Room6-A h 3140 77 37 0.103 6.0 0x0 ShMt 53.9 170.0 st2 Room7 h 1040 25 7 0.135 6.0 0x0 ShMt 6.0 165.0 st2 Room8 h 178 4 2 1 0.139 6.0 0x0 ShMt 1 10.5 155.0 stl Bold/italic values have been manually overridden 2014 -Jan -05 20:33:08 ti wrightsoft' Right -Suite® U niversal 201212 A 13 RSU08580 Pagel 11M ... s\OWNER\DocumentsWv ghlsoftware\Kanchner\Kaachner Sl259.rup Calc=MJ8 Front Ooorfams Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 179 80 0.099 514 8.0 0 x 0 ShtMetl stl Peak AVF 562 661 0.092 743 12.0 8 x 16 ShtMetl st1A Peak AVF 277 306 0.092 460 9.0 8 x 12 ShtMetl st1 st1B Peak AVF 157 150 0.092 235 7.0 8 x 12 ShtMetl st1A st1C Peak AVF 34 28 0.092 51 4.0 8 x 12 ShtMetl SOB Bold/italic values have been manually overridden 2014 -Jan -05 20:33:08 ti wrightsoft' Right -Suite® U niversal 201212 A 13 RSU08580 Pagel 11M ... s\OWNER\DocumentsWv ghlsoftware\Kanchner\Kaachner Sl259.rup Calc=MJ8 Front Ooorfams Return Branch Detail Table Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matt Trunk rb1 0x0 151 177 122.0 0.147 561 6.7 3.25x14 10x9 SJSp rt1 rb2 0x0 142 182 108.0 0.167 576 6.6 3.25x14 10x9 SJSp rt1 rb3 0x0 34 28 176.5 0.102 108 3.9 3.25x14 10x9 SJSp rt1A rb4 0x0 131 69 195.0 0.092 415 6.6 3.25x14 10x9 SJSp rt1B rb5 Oxo 177 145 92.0 0.196 562 6.3 3.25x14 10x9 SJSp rt1 rb6 0x0 106 140 190.5 0.094 442 6.7 3.25x14 10x9 SJSp rt1A Return Trunk Detail Table Bold/italic values have been manually overridden 2014 -Jen -05 20:33:08 $ Wright$Qft' Right-Suile® U niversal 2012 12.0,13 RSU08580 Paget AC7�A...a\OWNER\Documents\wrightsohware\Karlchner\KartchnerSl259.rup Calc=MJ8 FrontDoortaces: Trunk Htg Clg Design Veloc Diam lIx W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 741 741 0.092 667 13.2 8 x 20 ShtMetl rt1A Peak AVF 271 237 0.092 406 8.6 8 x 12 ShtMetl rt1 rt1B Peak AVF 131 69 0.092 197 6.6 8 x 12 ShtMetl rt1A Bold/italic values have been manually overridden 2014 -Jen -05 20:33:08 $ Wright$Qft' Right-Suile® U niversal 2012 12.0,13 RSU08580 Paget AC7�A...a\OWNER\Documents\wrightsohware\Karlchner\KartchnerSl259.rup Calc=MJ8 FrontDoortaces: Load Short Form Entire House *"a,High Country Heating q r sn aluUp P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Information Job: 51259 Date: Jan 05, 2014 By: Steve Dick Htg Clg Infiltration Outside db (*F) -6 89 Method Simplified Inside db (°F) 70 75 Construction quality Semi -tight Design TO (°F) 76 14 Fireplaces 0 Daily range - H Inside humidity (%) 50 50 Moisture difference (gr/Ib) 62 -31 HEATING EQUIPMENT Make Amana Trade Amana Model GMH950453BX AHRI ref 2002182 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 95 AFUE Make Amana 46000 MBtuh 34960 Btuh 51 °F 741 afm 0.025 cfm/Btuh 0.70 in H2O COOLING EQUIPMENT Make Amana Htg load (Btuh) Trade Amana Htg AVF (cfm) Cond GSX130181D` Room3 Coil ACNF18XX16D' 691 AHRI ref 46999441 17 Efficiency 11.0 EER, 13 SEER Sensible cooling 16800 Btuh Latent cooling 0 Btuh Total cooling 16800 Btuh Actual air flow 741 cfm Air flow factor 0.054 cfm/Btuh Static pressure 0.70 in H2O Load sensible heat ratio 0.97 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Room3 91 691 78 17 4 Room4 323 4312 2602 106 140 Room5 478 5457 3223 134 173 Room7 77 1040 122 25 7 Room8 52 178 38 4 2 Room10 245 3058 1886 75 101 Room12 135 1392 522 34 28 Room13 472 5605 3350 137 180 Room 11 146 2206 595 54 32 10—A ��n coin ., n7e —. .niv vu a ro r v I :J'1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014 -Jan -05 20:33:06 +` wrlghtSOft' Right -Suite® U niversal 2012 12.0.13 RSU06580 Page 1 rIC�`A...a\OWNER\Documents\wnghtsoftware\KanchnenKartchnerSl259.rup Calc=MJB FrontDoorfaces: Entire House d 2347 30218 13792 1 741 741 Other equip loads 0 0 Equip. @ 0.94 RSM 12965 Latent cooling 498 TOTALS I 234 I I I I 7 30218 13463 741 741 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014 -Jan -05 20:33:06 .L wrig 1tSOM Right -Suite® U niversal 2012 12.0.13 RSU08580 Page 2 AM ... s\OWNER\Documents\wn8htsoflware\Kanchner\KartchnerS1259.rup Cale =MJ8 Front Door faces: Building Analysis Entire House ° High Country Heating M,allnp It w IMnlel P.O. Box 627, Rigby, Id 83442 Phone: 208-7468056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 ]esion Conditic Job: S1269 Date: Jan O6, 2014 By: Steve Dick Location: Btuh/II2 Indoor: Heating Cooling Idaho Falls, ID, US 11553 Indoor temperature (°F) 70 75 Elevation: 4741 ft 18.3 Design TD (°F) 76 14 Latitude: 440N Ceilings Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (grAb) 61.5 -31.5 Drybulb(°F) -6 89 Infiltration: Ducts Dailyrange (°F) - 34 (H ) Method Simplified 0 Watbulb (°F) - 60 Construction quality, Semi -tight 0 Wind speed (mph) 15.0 7.5 Fireplaces 0 Adjustments Heating Component Btuh/II2 Btuh %of load Walls 4.7 11553 38.2 Glazing 26.9 5521 18.3 Doors 22.0 1389 4.6 Ceilings 1.5 3568 11.8 Floors 1.8 4269 14.1 Infiltration 1.8 3918 13.0 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total1 1 302181 100.0 Cooling Component Btuh/ft' Btuh % of load Walls 0.3 814 5.9 Glazing 34.4 7077 51.3 Doors 5.4 338 2.5 Ceilings 0.8 1972 14.3 Floors 0.0 80 0.6 Infiltration 0.2 361 2.6 Ducts 0 0 Ventilation 0 0 Internal gains 3150 22.8 Blower 0 0 Adjustments 0 Total 13792 100.0 Latent Cooling Load = 498 Btuh Overall U -value = 0.061 Btuh/ft'-°F Data entries checked. wri ittSof ' 2014 -Jen -0520:33:06 Rig S259.rup3 ale=MJ80 Pagel ...s\OWNER\Dowments\wiightsogwara\Kartchner\Karlchner Sl259.rup Calc=MJB Front Door faces: Component Constructions Job: 51259 Date: Jan 05, 2014 Entire House By: Steve Dick ° n�lnp High Country Heating Xnuq Ir ne it P.O. Box 627, Rigby, Id 83442 Phone: 208-7458056 Fax: 208-745-0817 Email: hlghwunbyhtg®gmail.wm For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 ]esicin Conditir Location: 0.065 Indoor: I Heating Cooling Idaho Falls, ID, US 200 Indoor temperature (°F) 70 75 Elevation: 4741 ft 1773 Design TD (°F) 76 14 Latitude: 440N 21.0 Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 DrybulbCF) -6 89 Infiltration: all 1564 0.065 Daily range (°F) - 34 ( H ) Method Simplified 742 Wat bulb (7) - 60 Construction quality Semi -tight 971 Wind speed (mph) 15.0 7.5 Fireplaces 0 19.0 Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain W "Ift -F M-°FMuh BW1M' Bluh BWhW Btuh Walls 12F-Osw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2'x6" wood frm 15B19-Owc-4: Bg wall, heavy dry or light damp soil, 2x4" wood int frm, concrete wall, r-19 cav ins, 8" thk, 1/2" gypsum board int fnsh Partitions (none) Windows 61C: 61C Doors 11 PO: Door, trill pur core type Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh n 421 0.065 21.0 4.94 2077 0.47 200 e 359 0.065 21.0 4.94 1773 0.47 170 s 446 0.065 21.0 4.94 2203 0.47 212 w 338 0.065 21.0 4.94 1670 0.47 160 all 1564 0.065 21.0 4.94 7724 0.47 742 n 224 0.047 19.0 4.33 971 0.08 18 e 180 0.047 19.0 4.22 760 0.07 13 5 272 0.047 19.0 4.41 1199 0.09 24 w 208 0.047 19.0 4.33 900 0.08 17 all 884 0.047 19.0 4.33 3830 0.08 72 n 51 0.290 0 22.0 1113 10.1 512 n 20 0.450 0 34.2 684 18.6 373 e 25 0.290 0 22.0 551 34.0 850 e 40 0.450 0 34.2 1368 67.1 2685 s 25 0.300 0 22.8 570 18.6 465 w 25 0.290 0 22.0 551 34.0 850 w 20 0.450 0 34.2 684 67.1 1342 all 206 0.450 0 26.9 5521 34.4 7077 n 21 0.290 10.5 22.0 463 5.36 113 s 21 0.290 10.5 22.0 463 5.36 113 w 21 0.290 10.5 22.0 463 5.36 113 all 63 0.290 10.5 22.0 1389 5.36 338 2347 0.020 50.0 1.52 3568 0.84 1972 2014 -Jan -05 20:33:07 WrightsQft' Right -Su It.® u niversa1201212.0.13 RSUOB580 Pagel AM ...s10VVNER\DocumentsXwdghtsoftware\KanchnenKartchner Sl259.rup Calc=MJ8 Front Doorfaces: Floors 19D-Ocstp: Fir floor, frm fir, 12" Mrs, tight crwl ovr, r-19 wall insul 330 0.368 19.0 1.32 436 0.24 80 21A -24c: Bg floor, heavy dry or light damp soil, 6' depth, carpet fir fnsh 2017 0.025 0 1.90 3833 0 0 t + WI'I JItiSQft' Right-Suile®Universal 201272.0.13 RSU08590 2014 -Jan -05 20:33:07 pege2 �� ...s\OWNER\Documents\wnghtsoftware\Kartchner\KarichnerSI259.mp Calc=MJB FrontDoorfsoes: Project Summary Entire House ° High Country Heating Nnenq e nlomq P.O. Box 627, Rigby, Id 83442 Phone: 208-746-8056 Fax: 208-745-0817 Email: highcounrryhtgagmail.com 1 For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Notes: Design Information Weather: Idaho Falls, ID, US Winter Design Conditions Outside db Inside db Design TD Heating Summary Structure Ducts Central vent (0 cfm) Humidification Piping Equipment load Infiltration Method Construction quality Fireplaces Job: SI259 Date: Jan 06, 2014 By: Steve Dick Summer Design Conditions -6 OF Outside db 70 OF Inside db 76 OF Design TO Daily range Relative humidity Moisture difference 30218 Btuh 0 Btuh 0 Btuh 0 Btuh 0 Btuh 30218 Btuh Simplified Semi -tight 0 Heating Equipment Summary Make Heating Cooling Area (ftp 2347 2347 Volume (fla) 15213 15213 Air changes/hour 0.22 0.11 Equiv. AVF (cfm) 56 28 Heating Equipment Summary Make Amana Trade Amana Model GMH950453BX AHRI ref 2002182 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 95 AFUE 46000 MBtuh 34960 Btuh 51 OF 741 cfm 0.025 cfm/Btuh 0.70 in H2O 89 OF 75 OF 14 OF H 50 % -31 gr/Ib Sensible Cooling Equipment Load Sizing Structure 13792 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Btuh Rate/swing multiplier 0.94 ton Equipment sensible load 12965 Btuh Latent Cooling Equipment Load Sizing Structure 498 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 498 Btuh Equipment total load 13463 Btuh Req. total capacity at 1.00 SHR 1.1 ton Cooling Equipment Summary Make Amana Trade Amana Cond GSX130181D' Coil ACNF18XX16D' AHRI ref 4699944 Efficiency 11.0 EER, 13 SEER Sensible cooling 16800 Btuh Latent cooling 0 Btuh Total cooling 16800 Btuh Actual air flow 741 cfm Air flow factor 0.054 cfm/Btuh Static pressure 0.70 in H2O Load sensible heat ratio 0.97 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrl htsoft' 2014 -Jan -0520:33:07 AMQ Rig RSU08580 ...s\OWNER\Dowments\waghtsoftware\Kadchner\Kadchner SI259,mp Calc=MJ8 Front Doorfaces: Page AED Assessment Entire House High Country Heating pgLy n On Iliollny P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Job: 51259 Date: Jan 05, 2014 By: Steve Dick Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature IT) 70 75 Elevation: 4741 ft Design TD IT) 76 14 Latitude: 44'N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Drybulb(7) -6 89 Infiltration: Dailyrange IT) - 34 ( H ) Mtbulb(°F) - 60 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 8 9 10 11 12 13 14 15 16 17 16 19 37 Rude, / Mou,IY / Ave, Maximum hourly glazing load exceeds average by 14.3%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh wri htsoft 2014 -Jan -052033:07 g Right -Suite® U niv er sal 201212.0.13 R SU08580 Pagel ,CCA s\OWNER\Documents\wnghtsoftware\Kartchner\Kaachner SI259.rup Calc=MJ8 Front Doorfaces: Right -J® Worksheet Entire House High Country Heating P.O. Boz 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcounlryhtgfgmail.com Job: 51259 Dale: Jan 05, 2014 By: Steve Dlck 1 Room name Entire House R 2 Exposed wall 339.5 h 9.0.0 it 8 3 Room height 8.0 It d 8.0 It heaVccol 4 Room dimensions 1.0 x 90.8 R 5 Room area 2347.3 ft' 90.8 fl' Ty Construction U -value Or I HTM I Area (ft') Load Area (ft') Load number (Blah/fly°F (Btuh/f P) or penmeterO 8 (Blah) or parameter (8) 1 (Blah) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VL 12F-Osw 0.065 n 4.94 0.47 492 421 2077 200 0 0 0 0 61C 0.290 n 22.04 10.14 51 0 111 512 0 0 0 0 Ls 11P0 0.290 n 22.04 5.36 21 21 463 113 0 0 0 0 15819-Owo4 0.069 n 4.33 0.08 244 224 971 18 0 0 0 0 11 61C 0.450 n 34.20 18.64 20 0 684 373 0 0 0 0 Yy 12F-Osw 0.065 a 4.94 0.47 384 359 1773 170 0 0 0 0 �G 61C 0.290 a 22.04 34.00 25 0 551 850 0 0 0 0 W 15819-0wo-4 0.069 a 4.22 0.07 220 180 760 13 0 0 0 0 �--G 61C 0.450 a 34.20 67.12 40 0 1368 2685 0 0 0 0 12F-0sw 0.065 s 4.94 0.47 492 446 2203 4/12 0 0 0 0 61C 0.300 s 22.80 18.60 25 0 570 465 0 0 0 0 We 0.290 s 22.04 5.36 21 21 463 113 0 0 0 0 W 15B79-Owo-4 0.069 s 4.41 0.09 272 272 1199 24 72 72 317 6 12F-Osw 0.065 w 4.94 0.47 384 338 1670 160 0 0 0 0 61C 0.290 w 22.04 34.00 25 0 551 850 0 0 0 0 11P0 0.290 w 22.04 5.36 21 21 463 113 0 0 0 0 t 15879-0wc-4 0.069 w 4.33 0.08 228 208 900 17 0 0 0 0 -G 61C 0.450 w 34.20 67.12 20 0 684 1342 0 0 0 0 C 168-50ad 0.020 - 1.52 0.84 2347 2347 3568 1972 91 91 138 76 F 19D-Ocsto 0.368 1.32 0.24 330 330 436 80 0 0 0 0 F 21A -24c 0.025 1.90 0.00 2017 2017 3833 0 Ip 91 91 172 0 61 c)AEDezcursion -11 Envelope lossigain 26300 10281 628 72 12 a) Infiltration 3918 361 63 6 b) Room ventilation 0 0 0 0 13 Internal gains: Occupents @ 230 5 1150 0 0 Appliances/other 2000 p Subtotal (lines 6 to 13) 30218 13792 691 78 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redismbu6on 0 0 0 0 14 Subtotal 30218 13792 691 78 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 1 ould1I = 1 1 3074181 137928 37411 6871 741 ATI?r�r-1 Air�r-1 d MCI) MCI) 741 7411 1 Calculations aooroved by ACOA to meet all requirements of Manual J 8th Ed Wrllght9of!' Right -Suite® Universal 2012 12.0.13 RSU08580 2014 -Jan -0520:33:07 ... s\OWNER\Documents\vnighlsoflware\Kanchner\Kartchner SI259.rup CeIc=MJB Front Door faces: Page 1 Right -J® Worksheet Entire House High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtgOgmail.win Job: 51259 Date: Jan 05, 2014 By: Steve Dick 7 Room name Room4 Rooms 2 Exposed wall 4B.5 It 63.0 it 3 Room height 8.0 R heaVcool 8.0 6 heat/cool 4 Room dimensions 1.0 x 322.5 ft 1.0 x 478.0 8 5 Room area 322.5 ft2 478.0 fP Ty Construction U-valueOr HTM Area (ft') I Load Area (w) Load number (Bluh/ft,'F (Bluh/f P) or perimeter (ft) (Bluh) or perimeter (ft) (Bluh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heal Cool 6 12F-ow0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 B1C 0.290 n 22.04 10.14 0 0 0 10 0 0 0 0 11P0 0.290 n 22.04 5.36 0 0 0 0 0 0 0 0 W 15879-0wo-4 0.069 n 4.33 0.08 716 96 406 7 128 128 564 11 17 �G 61C 0.450 n 34.20 18.64 20 0 684 373 0 0 0 0 W 12F-Osw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 �G 611C 0.290 a 22.04 34.00 0 0 0 0 0 0 0 0 t 75B19-O,vc-0 0.069 0 4.22 0.07 0 0 0 0 220 180 760 13 -G 61C 0.450 a 34.20 67.12 0 0 0 0 40 0 1368 2685 y/ 12F-Osw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 IL ----DG 61C 0.300 s 22.80 18.60 0 0 0 0 0 0 0 0 77 PO 0.290 8 22.04 5.36 0 0 0 0 0 0 0 0 w 15979-Owc-4 0.069 s 4.41 0.09 44 44 194 4 156 156 688 14 4(/ 12F-Osw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 IL---�D 61C 0.290 w 22.04 34.00 0 0 0 0 0 0 0 0 11 PO 0.290 w 22.04 5.36 0 0 0 0 0 0 0 0 Vy 15B19-Owo-4 0.069 w 4.33 0.08 228 208 900 17 0 0 0 0 �G 61C 0.450 w 34.20 67.12 20 0 684 1342 0 0 0 0 C 16B-50ad 0.020 - 1.52 0.84 323 323 490 271 478 478 727 402 F 19D-Ocsto 0.368 - 1.32 0.24 0 0 0 0 0 0 0 0 F 21A -24c 0.025 1.90 0.00 323 323 613 0 i 478 478 908 0 6 c)AED excursion 326 5g Envelope loss/gain 3971 2340 5015 3182 12 a) Infiltration 340 31 442 41 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants 230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 4312 2602 5457 3223 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4312 2602 5457 3223 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room to ad 4312 2602 5457 3223 Air requiretl (cfm) 106 140 134 173 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. jw -Pk Wfight9oft' I 2014 -Jan -0520:33:07 AGG1,, Right-Sulte® U Overeat 2012 12.0.13 RBU08580 Page t .s\OWNER\Documents\wrighlsoftware\Kaachner\Karichner S1259.rup Cale =MJB Front Door faces: Right -J® Worksheet Entire House High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-7458056 Fax: 208-745-0817 Email: highwunlryhlg@gmail.com Job: 51259 Date: Jan 05, 2014 By: Steve Dick 1 Room name Room? RoomB 2 Exposed wall 14.5 If 0 If 3 Room height 8.0 ft heaYwol 8.0 ft heal/cool 4 Room dimensions 1.0 x 77.0 ft 1.0 x 52.0 ft 5 Room area 77.0 fP I 52.0 ft- PTy Ty Construction U -value Or I HTM Area (ft-) I Load Area (f P) Load number (Btuh/ft "F (Bluhll[P) or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) 1 Heat Cool Gross N/P/S Heat Caol Gross NARIS Heal Cool 6 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 VL12F-Osw 61C 0.290 n 22.04 10.14 0 0 0 0 0 0 0 0 11P0 0.290 n 22.04 5.36 0 0 0 0 0 0 0 0 15879-0wo-4 0.069 n 4.33 0.08 0 0 0 0 0 0 0 0 11 61C 0.450 n 34.20 18.64 0 0 0 0 0 0 0 0 W 12F-0sw 0.065 a 4.94 0.47 36 36 178 17 0 0 0 0 �G 61C 0.290 a 22.04 34.00 0 0 0 0 0 0 0 0 Vy 15B19-Owc-4 0.069 a 4.22 0.07 0 0 0 0 0 0 0 0 1-G 61C 0.450 a 34.20 67.12 0 0 0 0 0 0 0 0 12F-Osw 0.065 s 4.94 0.47 80 80 395 38 0 0 0 0 61C 0.300 s 22.80 18.60 0 0 0 0 0 0 0 0 11 PO 0.290 s 22.04 5.36 0 0 0 0 0 0 0 0 w 151319-Owo4 0.069 s 4.41 0.09 0 0 0 0 0 0 0 0 12F-0sw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 61C 0.290 w 22.04 34.00 0 0 0 0 0 0 0 0 11P0 0.290 w 22.04 5.36 0 0 0 0 0 0 0 0 t 15B19.OwcA 0.069 w 4.33 0.08 0 0 0 0 0 0 0 0 -G 61C 0.450 w 34.20 67.12 0 0 0 0 0 0 0 0 C 16B-50ad 0.020 - 1.52 0.84 77 77 117 65 52 52 79 44 F 19D-0csto 0.368 - 1.32 0.24 0 0 0 0 0 0 0 0 F 21A -24c 0.025 1.90 0.00 77 77 146 0 I 52 52 99 0 61 c)AED excursion 1 -17 -5 Envelope loss/gain 838 103 178 38 12 a) Infiltration 203 19 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants 230 0 0 0 0 Appliances/other 0 g Subtotal (lines 6 to 13) 1040 122 i7g 3g Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1040 122 178 38 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 o ad I 10251 1271 1741 321 Alotar requ'!ed (dm) I 1 1 1 .i. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed Wright90ft' Rig ht -Su its® U niv ersal 2012 12.0.13 RSU08580 2014 -Jan -0520:33:07 ...s\OWNER\Documents\vrtightsoftwareV(anchnanKartchnar 51259.rup Cato =MJB Franl Door faces: Page 3 Right -M Worksheet e Entire House High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208745-8056 Fax: 208-745-0817 Email: highwuntryhtg@gmail.wm Job: Si259 Date: Jan 05, 2014 By: Steve Dick 1 Room name Room10 Room12 2 Exposed wall 33.5 ft 11.0 ft 3 Room height 8.0 ft heal/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 244.8 R 1.0 x 134.8 ft 5 Room area 244.8 W 134.8 ft' T Ty Construction U -value Or HTM Area ft' I Load Area ft2 Load I number atuh/ft"F (Btuh[W) or perimeter (ft) atuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool I 6 W 12F -Om 0.065 n I� 4.94 0.47 0 0 0 0 88 fib 336 32 -GG 61C 0.290 n 22.04 10.14 0 0 0 0 20 0 441 203 I 11P0 0.290 n 22.04 5.36 0 0 0 0 0 0 0 0 15819-0wo-4 0.069 n 4.33 0.08 0 0 0 0 0 0 0 0 11 61C 0.450 n 34.20 18.64 0 0 0 0 0 0 0 0 W 12F-Osw0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 I --G 61C 0.290 a 22.04 34.00 0 0 0 0 0 0 0 0 15819.0.c-4 0.069 a 4.22 0.07 0 0 0 0 0 0 0 0 61C 0.450 a 34.20 67.12 0 0 0 0 0 0 0 0 12F-0sw 0.065 s 4.94 0.47 124 124 613 59 0 0 0 0 81C 0.300 s 22.80 18.60 0 0 0 0 0 0 0 0 11P0 0.290 s 22.04 5.36 0 0 0 0 0 0 0 0 W 15B19-Owc-4 0.069 s 4.41 0.09 0 0 0 0 0 0 0 0 12F-0sw 0.065 w 4.94 0.47 144 119 588 56 0 0 0 0 611C 0.290 w 22.04 34.00 25 0 551 850 0 0 0 0 11P0 0.290 w 22.04 5.36 0 0 0 0 0 0 0 0 Yy 75BM0wc-4 0.069 w 4.33 0.08 0 0 0 0 0 0 0 0 �G 61C 0.450 w 34.20 67.12 0 0 0 0 0 0 0 0 C 16B-50ad 0.020 1.52 0.84 245 245 372 206 135 135 205 113 F 19Docstp 0.368 - 1.32 0.24 0 0 0 0 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 245 245 465 0 I 135 135 256 0 6c)AED excursion 212 -71 Envelope loss/gain 2588 1383 1238 278 12 a) Infiltration 470 43 154 14 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 3058 18 6 1392 522 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3058 1886 1392 522 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Arequir al momdI(cfm) 30551 188061 13341 112 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. j� � wrightsoR' 2014 -Jan -0520:33:07 RighteSKan®Universal 201259.rup3 RSU08580 Page4 ... s\OWNER\Documents\wri0htsoftware\Kartchner\Kartchner Sl259.rup Calc=MJS Front poor faces: Right -J® Worksheet Entire House High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcounlryhlg@gmail.com Job: SI259 Date: Jan 05, 2014 By: Steve Dick 1 Room name Rooml3 Rooml1 2 Exposed wall 56.5 it 25.5 R 3 Room height Be If heat/cool 8.0 it heallcool 4 Room dimensions 1.0 x 471.8 it 1.0 x 145.8 it 5 Room area 471.8 fP 145.8 fl' Ty Construction U -vale Or HTM Area (f P) Load Area (f 1') Load number (BtuZu"F: I (Bluh/f P) or perimeter (ft) (Bluh) or perimeter (f) I (Btuh) Heat Cool Gross N/P/S Heal Cool Gross N/P/S Heat Cool � 6 2F -ow 0.065 n 4.94 0.47 128 I 97 Tf�-I 477 46 116 96 474 46 IL 81C 0.290 n 22.04 10.14 11 0 231 106 20 0 441 203 I -DG 11P0 0.290 n 22.04 5.36 21 21 463 113 0 0 0 0 15819-Owc-4 0.069 n 4.33 0.08 0 0 0 0 0 0 0 0 11 61C 0.450 n 34.20 18.64 0 0 0 0 0 0 0 0 Vy 12F-0sw 0.065 a 4.94 0.47 196 171 845 81 0 0 0 0 1-G 61C 0.290 a 22.04 34.00 25 0 551 850 0 0 0 0 15B19-0wc-4 0.069 a 4.22 0.07 0 0 0 0 0 0 0 0 81C 0.450 a 34.20 67.12 0 0 0 0 0 0 0 0 12F-0sw 0.065 s 4.94 0.47 128 128 632 61 0 0 0 0 61C 0.300 a 22.80 18.60 0 0 0 0 0 0 0 0 11P0 0.290 s 22.04 5.36 0 0 0 0 0 0 0 0 W 15819-Owc-4 0.069 s 4.41 0.09 0 0 0 0 0 0 0 0 12F-osw 0.065 w 4.94 0.47 0 0 0 0 88 88 435 42 61C 0.290 w 22.04 34.00 0 0 0 0 0 0 0 0 11P0 0.290 w 22.04 5.36 0 0 0 0 0 0 0 0 15B19-Owc-4 0.069 w 4.33 0.08 0 0 0 10 0 0 0 0 61C 0.450 w 34.20 67.12 0 0 0 0 0 0 0 0 C 16B-50ad 0.020 - 1.52 0.84 472 472 717 396 146 146 222 122 F 19D-Ocsto 0.368 - 1.32 0.24 0 0 0 0 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 472 472 896 0 146 146 277 0 61 c)AED excursion -376 -81 Envelope loss7gain 4812 1277 1848 332 12 a) InBl"tion 793 73 358 33 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 2000 0 Subtotal (lines 61013) 5605 3350 2206 595 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 5605 3350 2206 595 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 NrleeQuir GI(chm) I I 56371 31801 22541 5321 Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed j� TF WrIQht90TY Right -Suite® Universal 2012 12.0.13 RSU08580 2014 -Jan -0520:33:07 ... s\OWNER\Documents\wdghtsofhvam\Kanchner\Kartchner SI259.mp Calc=MJB Front Doorfaces: Page Right -A) H Worksheet Entire House " High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highwuntryhtg@gmail.wm Job: 51269 Date: Jan 06, 2014 By: Steve Dick 1 Room name Room6 2 Exposed all 78.0 It 3 Room height 8.0 ft heaUwol 4 Room dimensions 1.0 x 330.0 ft 5 Room area 330.0 fl' Ty Construction U -value Or I HTM I Area (ft') I Loatl I Area Load number (Btuh/ftoF (Bluli f i) or perimeter (ft) (Btuh) or perimeter I Heal Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 4y 12F-0sw 0.065 n 4.94 0.47 160 160 790 76 1 -G 81 C 0.290 n 22.04 10.14 0 0 0 0 11 PO 0.290 n 22.04 5.36 0 0 0 0 151319-0wo-4 0.069 n 4.33 0.08 0 0 0 0 11 61C 0.450 n 34.20 18.64 0 0 0 0 W 12F-0sw 0.065 a 4.94 0.47 152 152 751 72 �G 61C 0.290 a 22.04 34.00 0 0 0 0 VL 151319-G."0.069 a 4.22 0.07 0 0 0 0 -C 61C 0.450 a 34.20 67.12 0 0 0 12F-Osv, 0.065 s 4.94 0.47 160 114 583 �0 61C 0.300 s 22.80 18.60 25 0 570 465 11P0 0.290 a 22.04 5.36 21 21 463 113 W 151319-Owc-4 0.069 s 4.41 0.09 0 0 0 0 0.065 w 4.94 0.47 152 131 647 62 L12F-Osw fi1C 0.290 w 22.04 34.00 0 0 0 0 11P0 0.290 w 22.04 5.36 21 21 463 113 W 151319-0wF4 0.069 w 4.33 0.08 0 0 0 0 �G 61C 0.450 w 34.20 67.12 0 0 0 0 C1613-50ad 0.020 1.52 0.84 330 330 502 277 F 19D-0oslp 0.368 - 1.32 0.24 330 330 436 80 F 21A -24c 0.025 1.90 0.00 0 0 0 0 I 61 c) AED exwrsion -36 Envelope loss/gain 5185 1276 12 a) Infiltration 1094 707 b) Room ventilation 0 0 13 Internal gains: Owupants @ 230 0 0 Appliances/other 0 Subtotal (lines filo 13) 6279 1376 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 6279 1376 15 Duct loads -0% 0% 0 0 oad 6179 73741 Airtreal qulretl Wm) I 1541 1 1 1 Calculations aooroved by ACCA to meet all reauirements of Manual J 8th Ed wrigl>tY90ft' Rig hl -Suite® U niv ersal 201212.0.13 RSU 08580 2014 -Jan -0520:33:07 ... s\OWNER\Documents\wdghtsoffware\KartchnenKanchner Sl259.rup Calc=MJB Front Doorfaes: Page Basement 12x8 Job M SI259 Performed by Steve Dick for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax 208-745-0817 highcountryhtg@gmail.com Scale: 1 : 69 Page 1 Rig ht -Su ite® U niversal 2012 12.0.13 RSU08580 2014 -Jan -05 20:34:41 ... reMartchnerWartchner S1259.rup Job M SI259 Performed by Steve Dick for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 higheountryhtg@gmail.com M-0 Scale: 1 :69 Page 2 Rig ht -Su ite® U niveMl 2012 12.0.13 RSU08580 2014 -Jen -05 20:34:41 ...reWartchneAKartchner S1259.rup family room Job M SI259 Performed by Steve Dick for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 77 cfm High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryhtg@gmall.com Scale: 1 : 69 Page 3 Rig ht-Suite®Universal 2012 12.0.13 RSU08580 2014 -Jan -05 20:34:41 ...re\KartchnerWartchner 81259.rup