Loading...
HomeMy WebLinkAboutFIRE ALARM SYSTEM - 14-00352 - BYUI Science and Technology11-0 U ?7c7-2- Nelson Sz Nelson I d I L I I Systems FIRE CONTROL INSTRUMENTS-GAMEWELL-HOSCH 1481 SOUTH MAJOR STREET S.L.C., UT 84115 P. 801-468-8300 F. 801-468-8305 www.iielsoufire.com Science and Technology Building Fire Alarm System Data Sheets January 12, 2015 BYU — IDAHO SCIENCE AND TECHNOLOGY BUILDING FIRE ALARM SYSTEM SUBMITTAL Equipment Manufacturer: Authorized Distributor: Gamewell-FCI Nelson Fire Systems 1481 South Major Street Salt Lake City, UT 84115 801-468-8300 Data Sheet Part No. Description Gamewell-FCI E3 Series Emergency Evacuation System Gamewell-FCI ILI-MB-E3 E3 Series Intelligent Loop Main Board Gamewell-FCI PM -9 E3 Series Power Supply Gamewell-FCI LCD -E3 E3 Series Remote Annunciator Gamewell-FCI ASM -16 E3 Series Addressable Switch Module Gamewell-FCI INCC-MIC E3 Series Microphone Gamewell-FCI INI-VGE-UTP E3 Series Voice Gateway Module Gamewell-FCI AA -120 E3 Series Bulk Amplifier Gamewell-FCI ASD-PL2F/B210LP Addressable Photo Smoke Detector Gamewell-FCI ATD-RL2F/B210LP Addressable Heat Detector Gamewell-FCI MS-7AF Addressable Pull Station Gamewell-FCI DNR Addressable Duct Detector Gamewell-FCI AMM -417 Addressable Monitor Module Gamewell-FCI AOM-2RF Addressable Control Module Gamewell-FC] PR -1 Auxiliary Relay Gamewell-FCI SPCW Speaker Only -Ceiling Gamewell-FCI SPRK Weatherproof Speaker Only Gamewell-FCI SPSW Speaker/Strobe-Wall Gamewell-FCI SPSCW Speaker/Strobe-Ceiling Gamewell-FCI HPFF8 NAC Power Supply FIRE CONTROL INSTRUMENTS by Honeywell Description The E3 Series. Expandable Emergency Evacuation System by FCI is in the forefront of the latest generation of fire alarm control panels. Employing the new high-speed Velociti" sensors, the E3 Series" provides previously unreachable polling speed and response together with the flexibility demanded by today's emergency evacuation systems. In addition to their high-speed polling rate, the VelocitiTN series of sensors feature bi-polar LEDs that flash green for normal polling, and light red steadily to indicate an alarm. The E3 Series' is equipped with an 80 -character LCD -E3 alphanumeric LCD display that allows 40 characters to be user -defined for customizing installa- tions. Up to six (6), keyboard LCD displays may also be remotely located in addition to five of the familiar LCD -7100 remote displays, allowing for instant system status information to be available in any desired area of an installation. The use of a high-speed 32-bit processor easily tackles a wide array of applications from small office buildings to sophisticated high rise installations. 64 -node networking is made possible by 625K baud/ ARCNET communications using twisted -pair copper cable, fiber-optic cable, or a combination of both. The basic E3 Series' is equipped with an ILI-MB-E3 Intelligent Loop Interface -Main Board and ASM -16 Addressable Switch Module that features sixteen (16), software programmable switches, each accompanied by red, green and yellow LEDs that can be programmed to indicate operation of the switches. Sixteen (16) additional optional ASM -16 modules may be added to expand the operation to a plateau previously unimagined. The Intelligent Loop Interface - Expansion Board (ILI-S-E3) provides the E3 SeriesTN control panel with two (2), additional signaling line circuits. The layout is similar to the ILI-MB-E3 with the exception that a number of components are omitted. When the ILI-S-E3 is used with the RPT -E3 Repeater, it occupies one node on the Broadband network. E3 Series" and Velocitir" are trademarks of Fire Control Instruments. E3 SerlestM Control Panel Expandable Emergency Evacuation System E3 Series*" Features • Two to 128 SLCs each supporting 99 sensors and 99 modules per circuit. • 625K baud ARCNET communications using wire, fiber, or mixed configurations for installation flexibility. • High-speed 32 bit processor. • 4100 event history log. • Advanced Boolean logic -based programming such as AND, OR, NOT, time delay and calendar functions configurable via computer programming. • Supports up to sixteen (16), ASM -16 addressable switch modules. • Supports up to sixteen (16), ANU-48 LED driver modules. • Two (2), Class A, Style Z or Class B, Style Y, notification appliance circuits rated at 2.0 amps. per circuit. • Integral city connection. • Flexible 115,200 baud high speed RS -232 interface. • 40 character user -defined text per device. • Styles 4, 6, or 7' signaling line circuits. • Supports up to five (5), LCD -7100 displays and six (6), LCD -E3 keyboard displays. • Listed under UL Standard 864, 9th Edition. *Style 7 wiring requires the use of System Sensor M50OX Isolator Modules. An ISO 9000-2000 Company aioNAUNG Cit, of Chicage 0<6N> MEA Approved Cityof LIMO Asrsoe App—c • Class I DENVER 91869 3026415 PENDING 71850894268 • class 2 Approved 71850694 269 • High Mae FIRE CONTROL INSTRUMENTS � 16 Southwest Park, Westwood, MA 02090—Tel 781-471-3000—Fax: 781-471-3099 Slxctiicalions are for information only, are not intended for installation purposes, and are subject to change vnfhout notice. No responsibility is assumed by Fire Control Instruments for their use. •200.5 Fire Control instruments. All rights reserved, www.firecontrolinstruments.com 9020-0637 Rev.0 pages of L J Description (continued) As many as sixteen (16), ANU-48 remote LED modules may also be added, furnishing hundreds of LEDs for remote annunciation. The ANU-48 modules may be installed in any Listed remote annunciator. It can be remotely located via an RS -485 serial interface. An array of cabinets allows for neat, compact, attractive installations. Installation The E3 Series a expandable emergency evacuation system offers four (4), cabinet size options. A typical cabinet includes a backbox, an inner door, and an outer door. The E3 Series" cabinet assembly is a compact 19" wide wall -mounted enclosure. Cabinet A includes two options: a two or three -bay outer door mounted to the backbox. The backbox typically houses one (1) LCD -E3, or one (1) NGA, and one (1) or two (2), ASM -16 modules. Cabinet B contains a space for the ILI-MB-E3, PM -9 modules and batteries set inside the backbox. Additional module options mounted on the backbox include the DACT-E3, RPT -E3 and ILI-S-E3. The 2 -Bay inner door houses one (1), LCD -E3 module and one (1), ASM -16 module. Both Cabinets C and D include the following: • Pre -assembled outer door panels that contain an enclosure for the fire fighter's phone handset and a microphone voice messaging system. • Two inner door panel selections that may contain optional modules to meet the facility operation requirements. • Inner Door Panel 1 accommodates up to eleven (11), ASM -16 modules and one LCD -E3 module. • Inner Door Panel 2 houses up to sixteen (16), ASM -16 modules, one (1). LCD -E3 or one (1), NGA. For instructions on installing any of the above E3 Series" cabinets, refer to the E3 Series" Expand- able Emergency Evacuation Installation/Operating Manual Part Number: 9000-0574. Specifications Operating Voltage: 24 VDC Operating Not to exceed the range of Temperature: 32" to 120 F (0 to 49" C) Relative Not to exceed 93% Humidity: Non -condensing at 90 F (32 C) Dimensions: Cabinet A:191/4'Wx10"Lx3"D Cabinet A (49 x 25 x 7.6 cm) LCD -E3 Cabinet B:19 3/8'W x 19 3/8" L x 4.5 D RPT -E3 -FO (49 x 49 x 11 cm) RPT -E3 -UTP Cabinet C:19 3/8" W x 30' L x 4.5" D E303 -A (49 x 76 x 11 cm) Cabinet B Cabinet D:19 3/8' W x 41' L x 4.5" D E3 -BB -BB (49 x 104 x 11 om) Ordering Information Model Description ILI-MB-E3 Intelligent Loop Interface -Mai NGA LCD Network Graphic Annunciator Board Power Supply Module ILI-S-E3 Intelligent Loop Interface -Expansion Cabinet A Board LCD -E3 LCD -E3, LCD Keypad Dis la RPT -E3 -FO Network Repeater Module RPT -E3 -UTP Cabinet A, Inner Door, 2 Slots DACT-E3 ANU-48 Digital Alarm Communicator Transmitter ANU-48 LED Driver Module ASM -16 Addressable Switch Module NGA LCD Network Graphic Annunciator PM -9 Power Supply Module LCD -7100 Remote LCD Display Cabinet A E3BB-BA Backbox with Door, (Black) E3BB-RA Backbox with Door, (Red) E302 -A Cabinet A, Inner Door, 2 Slots E303 -A Cabinet A, Inner Door, 3 Slots Cabinet B E3 -BB -BB Backbox with Door (Black) E3 -BB -RB Backbox with Door (Red) E302-13 Cabinet B, Inner Door, 2 Slots Cabinet C E3BB-BC/INCC Cabinet C, Backbox Enclosure, Command Center (Black) E3BB-RC/INCC Cabinet C, Backbox Enclosure, Command Center (Red) E3BB-BC/INX Cabinet C, Black Enclosure, Transponder E3BB-RC/INX Cabinet C, Red Enclosure, Transponder E31D2-C Cabinet C, Inner Door, Command Center, 7 Slots E31D3-C Cabinet C, Inner Door, Command Center, 8 Slots Cabinet D E3BB-BD Backbox with Door, (Black) E3BB-RD Backbox with Door, (Red) E31D2-D Cabinet D, Inner Door, 13 Slots (11 single and 2 double slots) E31D3-D Cabinet D, Inner Door, 14 Slots (12 single and one double slots) C FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090—Tel 781-471-3000—Fax: 781-471-3099 www.firecontrolinstruments.com 9020-0637 Rev. C page 2 of 2 FIRE CONTROL INSTRUMENTS by Honeywell Description ILI-MB-E3 The Intelligent Loop Interface -Main Board (ILI-MB- E3) is the main interface for the E3 SeriesTIA product line. With its state-of-the-art 32 bit RISC processor, this compact "panel on a board" pro- vides a powerful addition to FCI's single pair con- ductor solutions. This intuitive design provides two (2), signaling line circuits, two (2), notification ap- plication circuits, local energy city box output, aux- iliary relay functions, and auxiliary power out. These features, combined with built-in network and serial protocols, allow this module to support a host of new and existing products, resulting in a building block approach to fire alarm panel design. The ILI-MB-E3 is network ready and occupies one of 64 nodes, operating at 625K baud. When this sub -assembly is integrated with proven Broadband components, the result is a flexible yet powerful integrated audio solution. When transmitting to remote locations, the optional RPT -E3 provides the ILI-MB-E3 with valuable signal boosting and transient protection, as well as connectivity using both wire and fiber-optic cables. It provides two (2), signaling line circuits and termi- nals for the connections of all the E3 sub- assemblies. This board can support up to a total of sixteen (16), ASM -16 and/or sixteen (16), ANU-48 remote LED driver modules. The ILI-MB-E3 relay outputs include system alarm, supervisory, and system trouble contacts. The ILI- MB-E3 provides output for a local energy city mas- ter box or remote location which is non power - limited. All other wiring is power -limited. E3 Series- is a trademark of Fire Control Instruments. 1L1 -MB -E3 Series Intelligent Loop Interface -Main Board ILI-MB-E3 Features ILI-MB-E3 and ILI-S-E3: • Network ready integral 625K baud ARCNET. • 115.2K baud RS -232. • Signaling line circuits with: - Two (2), Class A, Style 6, 7 or Class B,Style 4 circuits. - 40 Character user -defined text per device. - Style 4, 6, or 7* operation. - Capacity of 99 sensors and 99 addressable devices per circuit. • Notification appliance circuits with: - Two (2), Class "A", Style Z, Class B, Style Y, Notification appliance circuits rated at 2.0 amps. per circuit, Styles Y and Z. • 4100 event history log. • Listed under UL Standard 864, 9th Edition. *Style 7 wiring requires the use of System Sensor M50OX Isolator Modules. ILI-MB-E3 Only: • RS -485 supporting sixteen (16), ASM -16 switch modules and/or ANU-48 LED driver modules. • Alarm, trouble, and supervisory dry contacts Form "C", rated at 2 amp. @ 30 VDC (resistive). • Supports six (6), local/remote LCD -E3 annunciators and five (5), LCD -7100 annunciators. An ISO 9000-2000 Company eba aro City of Chicagn �L<"> MEA Approved City of ug7Ep npnm.0 -Class I DENVER 61$E£ 302647E PENDING 7766.069421£ •Classi Approved 7165.06942f£ .High Rise FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090—Tel 781-471-3000—Fax: 781-471-3099 Specifications are for information only, are not Intended for installation purposes, and are subject to change vdthout notice. No responsit lity is assumed by Fire Control Instruments for their use. 02005 Fire Control Instruments. All rights reserved. www.firecontrolinstrumente.com 9020-0605 Rev. C page 1 of 2 ILI-S-E3 The Intelligent Loop Interface - Expansion Board (ILI-S-E3) provides the E3 SeriesTM control panel with two (2), additional signaling line circuits. The layout is similar to the ILI-MB-E3 except a number of components are omitted. The ILI-S-E3 occupies one node on the Broadband network. The Intelligent Loop Interface - Expansion Board (ILI-S-E3) pro- vides the E3 Series TM control panel with two (2), additional signaling line circuits. The layout is similar to the ILI-MB-E3 except a number of components are omitted. The ILI-S-E3 occupies one node on the Broadband network. Installation Typically, the ILI-MB-E3 or ILI-S-E3 can be mounted in the following E3 SeriesTM cabinets: Cabinet B and D, backbox. • Cabinet C, INX-E3 sub -assembly plate. • Cabinet C, INCC-E3 sub -assembly plate. Note: More than one ILI-MB-E3 or ILI-S-E3 can be mounted in Cabinet D. For instructions on installing the ILI-MB-E3 or ILI-S-E3, refer to the E3 Series" Expandable Emer- gency Evacuation Installation/Operating Manual, Part Number: 9000-0574, the ILI-MB-E3 Installation Instructions, Part Number: 9000-0579, or the ILI-S-E3 Installation Instructions, Part Number: 9000-0569. Specifications Operating Voltage: Operating Current: Alarm Current: Operating Temperature: Relative Humidity: 24 VDC FWR (from PM -9 Power Supply) 0.081 amp. 0.150 amp. max. 32° to 120° F (0° to 49° C) 0 to 93%, non -condensing at 90° F (32° C) 40 Ohms maximum line impedance. 0.5 pf maximum line capacitance. Ordering Information Model Description ILI-MB-E3 Intelligent Loop Interface -Main Board ILI-S-E3 Intelligent Loop Interface -Expansion Board FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090—Tel: 781-471-3000—Fax: 781-471-3099 www.firecontrolinstruments.com 9020-0605 Rev. C page 2 of 2 ^Gamewell IN�STRUOMEMS by Honeywell Description The PM -9 Power Supply is a component of NetSOLO® and E3 Series® fire alarm and voice evacuation systems. It provides power to the INX Transponder assembly and all E3 Series components. The PM -9 is a switching power supply that provides 9 amperes of filtered and regulated 24 VDC (nominal). It has an internal battery charging circuit capable of maintaining up to fifty-five (55), A/H batteries. This module is designed for use with the Gamewell-FCI distributed audio networks. Installation Typically, the PM -9 Module can be mounted in the follow- ing E3 Series cabinets: • Cabinet B and D, backbox • Cabinet C, INX-E3 sub -assembly plate • Cabinet C, INCC-E3 sub -assembly plate • Cabinet D. E3-INX-D Plate • Cabinet D, E3-ILI-D Plate For instructions on installing the PM -9, refer to the E3 Series® Expandable Emergency Evacuation Installation/ Operation Manual, Part Number: 9000-0574 or the PM -9 Installation Instructions, Part Number: 9000-0548. Specifications Input Voltage: 120 VAC 60 Hz Input Current: 4.6 amps max. Chicago @ 120 VAC 60 Hz Output Voltage: 24 VDC (nominal) FWR Output Current: 9 amperes Alarm max. Class continuous Output Current: 5 amperes Standby max. SINW.10 continuous (See Note 1) Alarm Current: 0.050 amp Operating Temperature: 32° to 120° F (O° to 49° C) Relative Humidity: 0 to 93% (non -condensing) at 90° F (32° C) Supervised Non Power -Limited Dimensions: 10 1/2"W x 5' H x 2" D (27Wx13Hx5Dcm) Note 1: Continuous standby loads in excess of .560 Amps up to 5 Amps may require Generator backup or load shed- ding during an AC power failure. E3 Seriese and NetSOLG® are registered trademarks of Honeywell International Inc. UL® is a registered trademark Undeiwrotiers Laboratories Inc. PM -9 PM -9 Power Supply PM -9 Features Listed under UL® Standard 864, 9th Edition 9 ampere, filtered, regulated power supply Energy and space saving switching technology Integral battery charger capable of recharging up to fifty-five (55), AH batteries (Batteries not furnished) Ordering Information Part Number Descrintion PM -9 Power supply An ISO 9000.2000 Company GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without nonce. No responsibility is assumed by Gamewel6FCl for Meir use. 02009by Honeywell International Inc. All rights reserved. www.gamewell-fel.com 9020-0555 Rev. J page 1 of 1 City of Rcawunn 4L Chicago O Approved any of LISTED rwarmren Class DENVER SHOW 14 0017416 71165-1701 Class l Apppse6 SINW.10 High Pox GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without nonce. No responsibility is assumed by Gamewel6FCl for Meir use. 02009by Honeywell International Inc. All rights reserved. www.gamewell-fel.com 9020-0555 Rev. J page 1 of 1 FIRE CONTROL INSTRUMENTS by Honeywell Description The LCD -E3 provides the main panel display of the E3 SeriesTM Expandable Emergency Evacuation System with indicating LEDs and operating switches. Up to six (6), LCD -E3 displays may be locally or remotely located from the panel via a local RS -485 bus of the ILI-MB-E3 sub -assembly. The LCD -E3 includes an LCD display for the system status and the following switches and LED indicators: Switches • AC Power • Alarm acknowledge • System reset/lamp test • Trouble • Programming buttons: acknowledge - menu/back (yellow) - back space/edit -OK • Signal silence • 12 button keypad LED Indicators • AC Power (green) • Power Fault (yellow) • Alarm (red) • Ground Fault (yellow) • Supervisory (yellow) • System Silenced (yellow) • System (yellow) Trouble Installation The LCD -E3 is adaptable for installation in any of the following E3 SeriesTM System cabinets: • "A" size cabinet, inner door (E=2 -A). • "B" size cabinet, inner door (E302-13). • "C" size cabinet, inner door (E302 -C). • "D" size cabinet, inner door (E302 -D). Ordering Information Model Description LCD -E3 LCD keypad display E3 Series" is a trademark of Fire Control Instruments. LCD=0 LCD Keypad Display LCD -E3 Features • Provides an 80 -character display of system events together with indicating LEDs and control switches. • The ILI-MB-E3 can support up to six (6), LCD -E3 displays, any or all of which may be remotely located via the RS -485 serial interface. • Easy to read backlit LED display, low power consumption. • Listed under UL Standard 864, 9th Edition. Specifications Operating Voltage: Alarm Current: 24 VDC FWR (from PM -9 power supply) 0.028 amp. Operating Current: 0.024 amp. Operating Temperature: 32' to 120' F (0' to 49' C) Relative Humidity: 0 to 93%, non -condensing at 90' F (32' C) An ISO 9000-2000 Company $10NALINe Ch", of UL Chicago FM 0 Approved City of LISTED .1.1C MEA • Class 1 DENVER E1869 3025415 PENDING 71650694 268 . Class 2 Approved 71650694 269 . High Rise FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090—Tel 781-471-3000—Fax: 781-471-3099 Specifications are for information only, are not intended for installallon purposes, and are sugect to change wipeout notice. No responsibility is assumed by Fire Control Instruments fortheir use. ©2005 Fire Control Instruments. All fights reserved. www.firecontrolinstruments.com 9020-0606 Rev. C page 1 of 1 LD FIRE CONTROL INSTRUMENTS by Honeywell Description The ASM -16 Addressable Switch Module is a component of NetSOLOTIA and E3 SeriesTm fire alarm and voice evacuation systems. It serves as the point of interface between an operator and the system's audio evacuation, fire fighter intercom, and building control circuits. The ASM -16 is a configurable switch input sub -assembly with sixteen (16), switches and forty-eight (48), status LEDs and may be remotely located via the RS -485 serial interface. Each ASM -16 addressable switch module has sixteen (16), push-button switches that can be programmed to serve any function the application demands. An ASM -16 switch can be programmed as a speaker circuit switch, fire fighter phone switch, an auxiliary control switch using a bank of three (3), switches (one switch each for on -off -auto functions), or switches with custom defined functions (e.g. system reset, system silence, system acknowledge, all -call, phone patch, lamp test, alarm tone on, manual select, etc.). Each ASM -16 switch also has three (3), fully programmable LEDs in red, yellow, and green. These LEDs can be programmed to work in concert with their associated push-button switch or they can be made to work independently as status indicators (e.g. on, off, normal, etc.). An INI-VGC assembly or ILI-MB-E3 can accommodate up to sixteen (16), ASM -16 modules for a total of 256 switches and 768 LEDs. Specifications Operating Voltage: 24 VDC (nominal) (from PM -9 power supply) Operating Current: 0.011 amp (with no LEDs lit) Operating Temperature: 32' to 120° F (0' to 49° C) Relative Humidity: 0 to 93% (non -condensing) at 90° F (32° C) E3 SedesT" and NeISOLOT- are trademarks of Fire Control Instruments. ASM -16 ASM -16 Addressable Switch Module Front View Rear View Features • Each INI-VGC supports up to sixteen (16), ASM -16 switch modules for a total of 256 switches. • Each ILI-MB-E3 supports up to sixteen (16), ASM -16 switch modules for a total of 256 switches. IN Each ASM -16 switch has three (3), fully programmable status, indicating LEDS: red, yellow, and green. • All switch functions are fully software programmable. • Slip -in label inserts allow easily modified switch designations. • Listed under UL Standard 864, 9th Edition. Ordering Information Model Description ASM -16 Programmable switch module An ISO 9001-2000 Company 810 LING City of Chicago rN Approved City of LISTED APPROVED MEA • np EA Clam 1 DENVER 5186! 7017616 217-03-E 06911-0694 257 •Class 2 Approved • High Rise FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090—Tel: 781-471-3000—Fax: 781-471-3099 Specirrations are for information only, are not intended for installation purposes, and are subject to change Winced notice. No responsibility is assumed by Fire Control Instruments for their use. -2005 Fire control Instruments. All rights reserved. www.firecontrolinstruments.com 9020-0554 Rev. G page 1 of 1 ^GamewelI aN%UMB�JT�SL by Honeywell Description The INCC Intelligent Network Command Center is a component of the E3 Series® Expandable Emergency Evacuation and E3 Series® Broadband Audio Evacuation System. The INCC Command Center serves as the point of interface between an operator and the system's audio evacuation, fire fighter intercom, and building control circuits. The INCC occupies a single node along the E3 Broadband network and is connected by a single pair of twisted, unshielded wire, fiber-optic cable or any combination of the two. Each E3 Broadband node can be spaced along the network a maximum distance of 3,000 feet (914.4 m) or up to an 8cIB loss using fiber-optic cable. Built-in isolation at each node permits Style 4, Style 6, and Style 7 network configurations. The E3 Broadband Audio Evacuation System is a peer- to-peer, self -regenerating, token ring network comprised of up to sixty-four (64), individual nodes. E3 Broadband employs proven technology and extends it to accomplish emergency voice evacuation, 2 -way Fire Fighter communications, and building control applications. It is unique in the industry in requiring only a single pair of wires or a fiber-optic cable connection between nodes to convey all fire alarm, digital voice, fire fighter communications, paging, and building control signals. A typical INCC assembly consists of an Intelligent Network Interface -Voice Gateway (INI-VGC) Module and one or more Addressable Switch Modules (ASM -16). INI-VGC. The INCC Command Center's INI-VGC module also provides connections for an optional emergency voice page microphone as well as a Fire Fighter tele- phone handset. The INI-VGC is a fully digital voice/tone generator using state-of-the-art Digital Signal Processing (DSP) technology to produce the clearest, most audible signal possible. The INI-VGC provides an output to a local speaker for message verification and testing. It is ideal for a wide range of complex System Applications including high-rise or campus installations. E3 Series® is a trademark of Honeywell International Inc. UO is a registered trademark of Underwriters Laboratories Inc. INCL Intelligent Network Command Center INCC Features • All communication signals and control -by -event sequences over twisted, unshielded pair of wires or fiber-optic cable including: - Audio Evacuation - Fan Control & Damper Shutdown - Voice Paging - Door Closures - Fire Fighter Intercom - Fire Alarm and Control Devices - Elevator Control - Horn/Strove Circuit Activation • Distributed architecture, including Style 7 wiring configurations, allow system components to continue normal operation with NO loss of function during single line fault conditions • Integrates with INX transponders and additional INCC command centers to create a complete audio evacuation system with up to 64 nodes • Each INI-VGC supports up to sixteen (16), ASM -16 switch modules for a total of 256 switches • INI-VGC connects to a voice page microphone and fire fighter's handset • Redundant command centers with microphone and fire fighter's handset easily configured by adding additional INCCs • Advance Boolean logic -based programming such as AND, OR, NOT, NOR, time delay, and calendar functions configurable through computer programming • Advanced digital signal processor (DSP) technology for efficient audio compression and filtering. Uses network data transfer rate at 625K baud • Listed under UL® Standard 864, 9th Edition An ISO 9001.2000 Company 1, Cty ofcag s VLA rN u Chio App.veE cayd rmea M� Cli.1 DENVER 51969 3017416 217-03-E 06911-0694:257 Clen2 Approves GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118 Specificalions are for information onty, are not intended for installatbn purposes, and are subject to change without notice. No responsibility is assumed by Fire Control Instmments for their use. 02)D8GamemI1FCl. Allrightsmserved. www.gamewell-fci.com 9020-0542 Rev. G1 page of ASM -16 Each Addressable Switch Module (ASM -16) has sixteen (16), push-button switches that can be programmed to serve any function the application demands. An ASM -16 switch can be programmed as a Speaker Circuit switch, Fire Fighter Phone switch, an Auxiliary Control switch using a bank of three (3), switches (one switch each for On -Off - Auto functions), or switches with custom defined functions (e.g. System Reset, System Silence, System Acknowledge, All -Call, Phone Patch, Lamp Test, Alarm Tone On, Manual Select, etc.). Each ASM -16 switch also has three (3), fully programmable status -indicating LEDs in Red, Yellow. and Green. The INCC assembly is enclosed in one or more compact 19" wall -mounted enclosures. Its modular construction provides complete flexibility in system design. Each cabinet can contain the INI-VGC and up to six (6), ASM -16 modules. If more ASM -16 modules are required, they may be mounted in additional INCC cabinets. As many as six (6), ASM -16 modules can fit in the INCC cabinet. If a Microphone module is required, it would take the place of one ASM -16 position. A Fire Fighter handset would take the place of two ASM -16 positions. An INI-VGC can support as many as sixteen (16), ASM -16s for a total of 256 completely programmable switches. The INCC operates on 24 VDC that can be sourced from the non-resettable auxiliary output of its associated power supply such as the PM -9. A complete E3 Audio Evacuation System can be assembled from three (3) different panels: one or more E3 Series fire alarm control panels, one or more INCC Audio Evacuation Command Centers, and one or more INX transponders. This modular approach greatly simplifies the design and installation process and can be configured to meet the exact needs of the project. Figure 1 INCC with MIC and Handset Ell 00 06 00 D11=1=1O Ell to 00 BD DB[_=IO Lie 10 01 10 DIE_=IO DIE=I=IO OBBO DIE=10 Do BE] OR B❑ 01 10 DIBD 01 BE] DI10 DI10 06 go of DIIO DI1O Oe1O mono 'a O Figure 1 INCC with MIC and Handset Ell 00 06 00 D11=1=1O Ell to 00 BD DB[_=IO Lie 10 01 10 DIE_=IO DIE=I=IO OBBO DIE=10 Do BE] OR B❑ 01 10 DIBD 01 BE] DI10 DI10 06 go of DIIO DI1O Oe1O DI10 DIBO Ell 1171 OI1O Do 10 Do 10 00 00 Ell 10 OI1O Do 10 DBID OR 00 06 in oil 10 C31 10 DI1O DIBO DBmID 01 00 Do 10 Do 00 OIC7CIIO 01 10 Lie 00 Figure 2 INCC with Six (6) ASM -16s GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118 www.gamewell-fci.com 9026-0542 Rev. G1 page 2 of 4 INCC BACKBOX WITH INI-VGC INCC INNER DOOR SHOWN WITH ASM -16 HANDSET & MICROPHONE ~ o 0 • 0 INNER DOOR ASSEMBLY®�a� ��• 21 Figure 3 INCC Assembly GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118 www.gamewell-fcixom 9020-0542 Rev. G1 page 3 of 4 Specifications Description Command center voice gateway INI-VGC Programmable switch module Operating Voltage: 24 VDC (nominal) Operating Current: 0.150 amp. supervisory and INCC-IDT alarm Operating INCC=TEL fire fighter handset and Temperature: 32° to 120° F (0° to 49° C) Relative Humidity: 0 to 93% (non -condensing) Protocol Asynchronous with half -duplex data flow Speed RS -232 up to 64 KBps RS -485 up to 128 KBps St connectors Up to 200 microns (multimode), optimized for 62.5/125 microns ASM -16 Operating Voltage: 24 VDC (nominal) Operating Current: 0.005 amp supervisory 0.005 amp alarm plus 0.003 amp per LED activated (0.195 amp max.) Operating Temperature: 32° to 120° F (0 to 49° C) Relative Humidity: 0 to 93% (non -condensing) Ordering Information Intelligent Network Command Center INI-VGC Command center voice gateway ASM -16 Programmable switch module (occupies one single slot of inner door) INCC-IDT Inner door with one double slot for INCC=TEL fire fighter handset and 4 single slots INCC-ID Inner door with six (6), single slots INCC-CAB INCC backbox (black) with black outer door. 19" W x 19" H x 4" D (48 x 48 x 10 cm) NCC-CABR INCC backbox (black) with red outer door 19" W x 19" H x 4" D (48x48x10cm) Optional Accessories INCC-TEL Fire fighter telephone handsel (requires INCC-IDT Inner Door) INCC-MIC Paging microphone module (occupies one single slot of Inner Door) INCC-BP Command center blank face plate (occupies one single slot of inner door) GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118 www.gamewell-fci.com 9020-0542 Rev. G1 page 4 of 4 ^Gamewell a FIRE CONTROL © INSTRUMENTS by Honeywell Description The following sub-assembliesare components of the E3 Broadband Audio Evacuation System and optional com- ponents of the E3 SeriesTm Expandable Emergency Evac- uation System: • INI-VGC • INI-VGE • INI-VGX INI-VGC The INI-VGC Voice Gateway Module provides command and control functions for the INCC Command Center. The INCL serves as the point of interface between an operator and the system's audio evacuation, fire fighter intercom, and building control circuits. Atypical INCL assembly consists of an Intelligent Network Interface -Voice Gateway (INI-VGC) Module and one or more Addressable Switch Modules (ASM -16). Each INI- VGC can support up to sixteen (16), ANU-48 LED Driver Modules or ASM -16s for a total of 256 fully programmable switches and 768 LEDs (red, yellow, and green). The INI-VGC occupies a single node on the E3 Broad- band network and is connected by a single pair of twisted, unshielded wire, fiber-optic cable or any combination of the two. The INI-VGC-UTP is not equipped with fiber-optic connectors. The INCC Command Center's INI-VGC module also pro- vides connections for an optional emergency voice page microphone as well as a Fire Fighter telephone handset. The INI-VGC is a fully digital voice/tone generator using state-of-the-art Digital Signal Processing (DSP) technol- ogy to produce the clearest, most audible signal possible. The INI-VGC provides an output to a local speaker for message verification and testing. E3 Series"' is a trademark of Honeywell Intemadonal Inc. INIM Series INI-VG Command Center INI-VG Features Voice Gateway The INI-VG Series include the following features: • Listed under UL Standard 864, 9th Edition. • All communication signals and control -by -event sequences over twisted, unshielded pair of wires or fiber-optic cable. • Distributed architecture, including Style 7 wiring configuration, allows system components to continue normal operation with NO loss of function during single line fault conditions. • Each INI-VGC or INI-VGE supports up to sixteen (16), ANU-48 LED drivers or ASM -16 switch modules for a total of 256 switches. • INI-VGC connects to a voice page microphone and fire fighter's handset. • Redundant command centers with microphone and fire fighter's handset easily configured by adding INCCs. • Advanced digital signal processor (DSP) technology for efficient audio compression and filtering. • Network data transfer rale at 625K baud. The INI-VGX includes the following features: • Software -programmable multi -channel digital audio applications. • One Style 4 signaling line circuit (SLC) supporting up to thirty-two (32), addressable speaker circuits. • AOM-MUXF for dual channel) and sixteen (16), addressable phone circuits (AOM-TELF). • Supports up to 150 watts of audio power (AM -50 amplifier modules) with additional 50 watts of standby in a single, compact wall - mounted cabinet. • 16 message capacity with up to 3 minute duration per INX and messages are easily field -configured via a laptop computer. An Is09000.000 Con iomy n� 9� 0« nEa Cm,d emn w,w,m A m,.r xmve sam mwe �e .xoe®,zn w,.s py,ae xqn. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specricatbns are for informadon only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. `®2007 Honeywell international Inc. All rights reserved. www.gamewell-fcl.com 9020-0648 Rev. Cl page l of 2J INI-VGC (Continued) The E3 Broadband Audio Evacuation System is a peer-to- peer, self regenerating, token ring network comprised of up to sixty-four (64), individual nodes. Each E3 Broadband node can be spaced on the network a maximum distance of 3,000 feet (9%4 m) or up to an 8dB loss using fiber-optic cable. Built-in isolation at each node permits Style 4, 6, and 7 net- work configurations. INI-VGE The INI-VGE Voice Gateway Module provides command and control functions for the INCC Command Center. It provides bulk amplification. A typical INCC assembly consists of an Intelligent Network Interface -Voice Gateway (INI-VGE) Module and one or more Addressable Switch Modules (ASM -16). Each INI- VGE can support up to six (6), ASM -16s for a total of 96 fully programmable switches and 288 LEDs (red, yellow, and green). The INI-VGE occupies a single node on the E3 Classic net- work and is connected by a single pair of twisted, unshielded wire, fiber-optic cable or any combination of the two. The INI-VGE-UTP is not equipped with fiber-optic con- nectors. The INCC Command Center's INI-VGE Module also pro- vides connections for an optional emergency voice page microphone as well as a fire fighter telephone handset. The INI-VGE is a fully digital voice/tone generator using state-of-the-art Digital Signal Processing (DSP) technology to produce the clearest, most audible signal possible. The INI-VGE provides an output capable of driving up to 20 Model AA -100 or AA -120 amplifiers. INI-VGX The INI-VGX Transponder Voice Gateway is a component of the E3 Broadband Audio Evacuation System and an optional component of the E3 Series Expandable Emer- gency Evacuation System. It is a multi -function module that incorporates: • Network interface using twisted, unshielded wire or fiber-optic cable. • Fully digital message generator. • One (1) signaling line circuit for local peripheral devices. • Local fire fighter phone riser. It occupies a single DIP switch selectable address on the network and provides termination points for the network connection using either a pair of twisted, non -shielded wire (12 AWG max.) fiber-optic cable, or a combination of the two. The INI-VGX-UTP is not equipped with fiber-optic con- nectors. The INI-VGX provides command and control for up to four (4), AM -50, 50 watt amplifiers in a single cabinet. The INI- VGX uses advanced Digital Signal Processing (DSP) tech- nology for audio compression and filtering allowing E3 Broadband to produce the clearest audio possible. Back- ground noise is automatically filtered during voice paging and fire fighter communications increasing audibility and eliminating the need for Push -to -Talk devices. Specifications INI-VGC, INI-VGE and INI-VGX Operating Voltage: 24 VDC (nominal) Operating Current: 0.150 amp. supervisory and alarm Operating Temperature: 320 to 120° F (0 to 49° C) Relative Humidity: 0 to 93% (non -condensing) Protocol: Asynchronous with half -duplex data flow Speed: RS -232 up to 64 KBps RS -485 up to 128 KBps St connectors': Up to 200 microns (multimode), Optimized for 62.5/125 microns *St Connectors are omitted on the INI-VG-UTP Series. *Model INI-VGC only Ordering Information INI-VGC Model Description INI-VGC Command center voice gateway INI-VGC-UTP Command center—(unshielded twisted -pair only) INI-VGE INI-VGE Command center voice qateway INI-VGE-UTP Command center (unshielded twisted -pair only) IN[-VGX INI-VGX Transponder voice gateway INI-VGX-UTP Transponder voice gateway (unshielded twisted -pair) GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 `9020-0648 Rev. C1 page 2 of 2 www.gamewell-fci.com ^m Gaemll a FIRECONTROL © INSTRUMENTS by Honeywell Description The Gamewell-FCI AA Series audio amplifiers provide the latest audio technology and bulk amplification for the Gamewell-FCI E3 Si Classic Emergency Voice Evacuation System. Two (2) models are available. The Model AA -100 provides 100 watts @ 70.7 VRMS (power -limited), while the Model AA -120 provides 120 watts @ 25 VRMS (power -limited). Both models use high -efficiency, power -switching, regula- tion technology to reduce the generation of heat, and mini- mize the size for ease of installation. An integral automatic back-up tone generator allows for slow whoop or high/low signal tones. The amplifiers include power supply, battery transfer control, amplifier supervision and back-up amplifier transfer control. Indicators and Controls Normal Level Green LED Incorrect Level Yellow LED Amplifier Trouble Yellow LED Speaker Trouble Yellow LED Brown-out/AC Failure Yellow LED Battery Supervision Yellow LED Specifications Rated Output: 100 watts RMS (AA -100) 120 watts RMS (AA -120) Output Voltage: 70.7 VRMS (AA -100) 25 VRMS (AA -120) Total harmonic distortion@ 1 kHz: 4.0% Frequency response (+3, AdB): 170-7,500 Hz Supply Voltage: 120 V, 60 Hz Power consumption Standby: .306 A @ 120 VAC: Alarm: 1.85 A 24 VDC (battery) consumption: Standby: .051 A Alarm: 6.5 A (AA -100) 7.3 A (AA -120) Dimensions: 7.0" H x 19.0" W x 4.5' D (17.8Hx48.3INx11.4Dcm) Weight: 16.0 lbs. (35.3 kg.) E3 Seriese is a registered trademark of Honeywell Internaficnal Inc. AA Series Amplifiers Amplifiers for Emergency Voice Evacuation Systems AAAmplifier Features • AA -100 provides dual outputs of up to 100 watts @ 70.7 VRMS (max. 100 watts of combined output) • AA -120 provides up to 120 watts @ 25 VRMS • Low power standby mode for low battery drain • Includes "Grouped" or "One -to -One" backup amplifier switching bus • Battery input and brown -out transfer control • High efficiency power -switching regulation technology • Plug-in terminal strips and cable connectors for ease of installation • 10 -position level adjust and indicator LEDs • Integral chassis for cabinet mount • Includes automatic back-up tone generator (slow whoop or high/low) Ordering Information Part Number Description AA -100 Am Iffier 100W AA -120 -Amplifier, 120W An ISO 9001-2000 Company SIGNALING @ FM MEA �! Approved LISTED ArrAoveo FDNY: 51949 3022355 COA46077 7165-1703:0125 6911-1703:0115 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for intonation only, are not intended for installation purposes, and are sulced to change without notice. No responsibility is assumed by Gamewell-PGI for their use. 020121cy HoneymIllntemaionallnc. Arrightsmserved. www.gamewell-fci.com 9020-0595 Rev. F page 1 of 1 J ^Gamemll 00 it 011 FIRE CONTROL INSTRUMENTS by Honeywell Description The FCI-CHG-120 is the compatible battery charging sys- tem is designed for use with the AA -100 and the AA -120 bulk amplifiers. It is used to charge lead -acid batteries at a power supply between 25 and 120 ampere -hours (A/H). Construction and Application The FCI-CHG-120 consists of a PC board and a mounting chassis. Applications Use the FCI-CHG-120 battery charging system when the batteries are required for standby amplifiers that are rated between 25 to 120 A/A The FCI-CHG-120 has the capabil- ity to charge two (2) 26 A/H batteries or two (2) 50 A/H bat- teries. Installation You can install the FCI-CHG-120 within 20 ft. (6.096 m) from the main fire alarm control panel. There are a variety of mounting options available for the FCI-CHG-120. The FCI-CHG-120 can be mounted in the following two back - boxes: • CABA Series backbox • FCI-LBB Battery backbox (used for remote installations) CAB -4 Series Backbox Installation To mount the FCI-CHG-120 to the CAB -4 Series backbox, do the following: 1. Mount the FCI-CHG-120 in the main power supply position on the lower left corner of the CAB -4 Series backbox. 2. Position the FCI-CHG-120 in the lower right location (usually located where the batteries are mounted) of the CABA Series backbox. 3. To secure the FCI-CHG-120 to the CABA Series back - box, use self -tapping screws. FCI-LBB Backbox Remote Installation To mount the FCI-CHG-120 to the FCI-LBB Series back - box, do the following: 1. Mount the FCI-CHG-120 in the left side of the FCI-LBB backbox. 2. To secure the FCI-CHG-120 to the FCI-LBB Series backbox, use self -tapping screws. Note: Only one (1) 55 A/H battery or two (2) A/H batteries will mount with the charger board in the BB-FF/FCI-LBB cabinet. The following list the types of batteries: - Up to two (2) 26 A/H batteries. - Up to two (2) 55/60 A/H batteries. - One (1) 100 A/H battery. FCI-CNG-120 Battery Charging System FCI-CHG•120 Features • Complies with the following UL Standards for fire alarm systems: - UL Standard 864 for control units - UL Standard 1481 for power supplies • Conforms to NFPA 72 National Fire Alarm Code. • Operates on any 24 -volt FACP that requires the speci- fied batteries and can disable the local charger. • Charges sealed lead -acid batteries. • Includes an automatic float -type battery charger. • Obtains a full float voltage within 48 hours. • Supports AC fail delay (central station applications) per the latest NFPA Standards. • Is rated for batteries of 25 to 120 ampere -hours. • Provides Form -C Trouble contact and dual outputs for easy load distribution. • Offers an optional FCI-LBB battery cabinet. • Contains the following Diagnostic LEDs: - Primary AC ON - Lo Charge - Charger Trouble - Battery Voltage Level (3 LEDs) - Ground Fault - Low Battery - Hi Charge • Produces the following charge amperes hours: - 24 AH batteries within 9 hours. - 55/60 AH batteries within 20 hours. - 120 AH batteries within 38 hours. An ISO 9001-2000 Company moOll� MEA FDNY 0 U& .PP. PD LISTED ADDm.ea Approved 3670 195-91£ 6026, 6018 11654701:0115091191 3 17 -01£ VDL9 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are sublecl to change without notice. No responsibility Is assumed by Gamewell-FCI for their use. 02012 by Honeywell lntemational Inc. All rights reserved. VJVYw.gamewell-fcl.com 9021-60722 Rev. B page 1 of 2� Installation (Continued) With the FCI-CHG-120 mounted internally, the following batteries can be used. - Up to two 26 AM batteries - One 55/60 A/H battery - One 100 A/H battery Note: When 100 A/H batteries are required, use an FCI- LBB to mount each 100 AM battery. The FCI-CHG-120 can mount in either of the following backboxes: - CAB -4 Series backbox - Third FCI-LBB backbox in this configuration Specifications Primary AC (TB1): 115 VAC, 60 Hz, 2 A. 230 VAC, 50 Hz 1 Form -C Relay (TB3): 5A @ 30 VDC Float Charge Voltage: 27.6 VDC Maximum charging current: 4.5 A Fuses F1 -F3: 15A Battery sizes: 25 AM to 120 AM Charging time (to charge two (2) fully discharged batteries): 25 A/H battery 9 hours charging time 55 A/H battery 20 hours charging time 120 A/H battery 38 hours charging time Ordering Information Part Number Description FCI-CHG-120 Battery charger circuit board and mounting chassis (Includes mounting hardware and installation instructions) BAT -12260 26 AM, 12 -volt, sealed lead -acid battery BAT -1250 55 A/H, 12 -volt, sealed lead -acid battery BAT -121000 100 A/H, 12 -volt, sealed lead -acid battery FCI-LBB Battery backbox (black) The battery backbox holds the following: - two (2) BAT -12550 55 A/H batteries or - one (1) BAT -121000100 A/H battery Dimensions: Backbox 24"W x 14" H x 7.75" D (61 W x 35.6 H x 19.7 D cm) Door 24.125" W x 14.25' H x 0.063" D (61.3 W x 36.2 H x 0.16 D cm) FCI-LBBR Battery backbox (red) Dimensions: Backbox 24" W x 14" H x 7.75" D (61 W x 35.6 H x 19.7 D cm) Door 24.125" W x 14.25' H x 0.063" D (61.3 W x 36.2 H x 0.16 D Gm) GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60722 Rev. B page 2 of 2 www.gamewell-fci.com ^Gamewell 0 [0 INSSTRUUMENTS by Honeywell Description The Gamewell-FCI Velociti® Series, multi -mod six signal output module (MMO-6SF) provides six (6), Style Y (Class B) or three (3), Style Z (Class A) supervised control circuits suitable for a wide range of signaling applications. Each supervised circuit may be used as a: • Audio speaker circuit. • Notification applicance circuit. • Supervised control output. The Velociti® Series use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The MMO-6SF connects to the signaling line circuits (SLC) of the Gamewell-FCI analog addressable series fire alarm control panels. Each of the MMO-6SF supervised control circuits occupies its own address on the system's SLC allowing each to be fully programmable in its control -by - event sequence of operation. The address of the first supervised output circuit is set with a pair of rotary dials. Each remaining circuit is automati- cally assigned to its own subsequent address. The MMO- 6SF module includes an address disable jumper matrix that allows one, two, or three addresses to be turned off to free these addresses for other purposes. An additional jumper setting selects either Style Y or Style Z circuit con- figurations. A wide range of configurations are possible including 30 VDC, audio input at 25 or 70.7 VRMS, 125 VAC, etc. More than one circuit can share a power supply if the current capacity does not exceed the power supply's output. Each output circuit on the MMO-6SF monitors its own con- nection to its power supply and will indicate a fault condi- tion by address if the power source should fail. The MMO- 6SF is also provided with short circuit monitoring to protect the external power source from short circuits on the notifi- cation appliance circuit wiring. This feature can be disabled per individual circuit if the application requires. Veluc t@ and E3 Series@ are registered trademarks of Honeywell International Inc. Velociti° Series MMo-6SF Multi -MOD Six Signal Output Module Features • Each MMO-6SF module provides six (6), Style Y (Class B) or three (3), Style Z (Class A) individually address- able, individually programmable notification appliance or supervised output circuits • Removable wiring terminal blocks allow ease of installa- tion and servicing • Terminal blocks can accommodate 12 to 18 AWG wire • Flexible jumper configuration feature allowing up to three (3), output circuit addresses to be disabled • Accommodates multiple external power inputs • External power monitoring • Short circuit protection of external power supplies • Sources providing AC, DC, or audio inputs • Designed for use with Gamewell-FCI analog address- able series fire alarm control panels • Individual LED indicators` • Ideal for retrofit applications • Two (2), mounting cabinets available for two (2), (MBB - 2 cabinet) to six (6), (MBB -6 cabinet) units Note: "Only the red LED is operative in panels that do not operate in Velociti® mode. stcruuxa & FM MEA LISTED �e Appraed S1913 3023594 219-02-E Vol. M 7300-1703:0124 ASO 9007 GAMEWELL-FCI ••��•• •�••�•• 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 ��•• •• Specifications are for information only, are not intended for Installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. 02013 Honeywell International Inc All rights reserved. www.gamewell-feLCom 9020-0634 Rev. D page 1 of 2 Description (Continued) (Note: power supply monitoring must also be disabled in such cases.) Each circuit has its own status LED that Flashes to indicate proper polling and lights steadily when the output has been activated. Two (2), multi -mod series units can be mounted in one MBB -2 cabinet. Additional mounting options include the MCH -6 chassis that can accommodate six multi -mod series modules. The MCH -6 chassis can be installed in a custom cabinet or can be mounted in the MBB -6 cabinet allowing up to six (6), multi -mod series modules in one cabinet. The MMO-6SF is ideal for applications where centralized location of circuits is required. As many as thirty-six (36), supervised output circuits may be located in a cabinet that is only 12.63" H x 24" W x 6.5' D in dimension saving valu- able wall space in mechanical rooms and electrical closets and reducing cost of installation. Specifications Operating Voltage: 15-32 VDC Stand-by Current: 2.25 mA Alarm Current: 40 mA (with all six LEDs lit) Maximum IDC Wire 25 Ohms Resistance: 30 VDC Temperature Range: 32" F to 120° F (0° to 49° C) Humidity 10 to 85% (non -condensing) Dimensions: 6.8" H x 5.8" W x 1.25' D (17.3 x 14.7 x 3.2 cm) MBB -2 12.25" H x 9.25' W x 3.32" D 0.5A (31.1 x 23.5 x 8R cm) MBB -6 12.63" H x 24" W x 6.5' D (32 x 60.1 x 16.5 cm) External Supply Voltage DC Voltage: 18-28 Volts, Resistive Class 2 Power -Limited Ripple Voltage: 0.1 Volts rms maximum Current: 90 mA per module Contact Ratings Current Maximum Load Rating Voltage Description Application 3A 30 VDC Resistive Non -coded 2A 30 VDC Resistive Coded 1A 30 VDC Inductive Coded (UR= 2ms) 0.5A 30 VDC Inductive Coded (UR= 5ms) 0.9A 110 VDC Resistive Non -coded 0.9A 125 VAC Resistive Non -coded 0.7A 70.7 & VAC Inductive Non -coded (PF= 0.35) 0.5A 125 VAC Inductive Non -coded (PF= 0.35) Ordering Information Part Number Description MMO-6SF Multi -Mod 6 zone interface module MBB -2 Backbox, 2 unit Mai Backbox, 6 unit, requires MCH -6 MCH -6 6 -Unit mounting chassis GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0634 Rev. D page 2 of 2 www.gamewell-fci.com ^Gamewell IN�SfRUCt1EI�S by Honeywell Description The Gamewell-FCI Velociti® Series, analog address- able plug-in smoke sensors with integral communica- tion provide features that surpass conventional sensors. Sensitivity can be programmed in the con- trol panel software, and is continuously monitored and reported to the panel. Point ID capability allows each sensor's address to be set, providing exact locations for selective maintenance when the cham- ber contamination reaches an unacceptable level. The ASD-PL2F photoelectric sensor's unique optical sensing chamber is engineered to sense smoke pro- duced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed -tem- perature thermal sensing on the ASD-PTL2F model. The Velociti® Series use a communication protocol that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concen- trates on the single device. The net effect is a response speed up to five times greater than earlier designs. ordering Information Part Number Description ASD-PL2F Analog, addressable photoelect ronic F�plsmoke sensor ASD-PTL2F Analog, addressable photoelectronic smoke sensor with thermal sensing ASD-PL2FR Analog, addressable photoelectronic smoke sensor used with the DNR duct base when the remote test is required. Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Velociti° Series ASD-PL2F, ASD-PTL2F and ASD-PL21`1 Analog, Addressable Photoelectronic Smoke Sensor A8D-PL2FIASD-PTL2F Features Sleek, low -profile design. ASD-PL2FR • Visual rotary, decimal switch addressing (01-159). • Built-in functional test switch activated by an external magnet. • Bicolor LEDs flash green whenever the sensor is addressed, and light steady red on alarm." • Optional relay, isolator, or sounder bases. Low standby current. • Analog addressable communication. • Stable communication technique with noise immunity. • Optional remote, single -gang LED Indicator (RA100Z). • Compatible with Gamewell-FCI analog addressable panels. I Note: *02 the red LED is operative in panels that do not operate in Velociti mode. SIGNALING L FM MEA 0 d Approved LISTED APPROVEDFI)NY 51913 3023594 COA#:219-02•E 7272.1703:0121 vol.vl ASO 9001 GAMEWELL-FCI '•'"' """' 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 �•� Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. 2013 by Honeywell international Inc. All rights reserved. WWW.gamewell-fcl.com 9020-0617 Rev. J page l of 2 l Installation ASD-PL2F plug-in sensors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: • 4.0" (10.2 cm) square box. • 3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box. • Single -gang box (except relay or isolator bases). • With B200S or B200SR base, mounted on a 4.0" (10.2 cm) octagonal or square box. • With B224RB or B224BI base, mounted on a 3.5" (8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or square box. NOTE: Because of the inherent supervision provided by the SLC, end -of -line resistors are not required. Wring "T -taps" or branches are permitted for Style 4 (Class "B") wiring. Sensor Spacing Gamewell-FCI recommends that the spacing sensors be used in compliance with NFPA 72. Specifications ASD-PL21F, ASD-PTL2F, ASD-PL2FR: Dimensions: 2.1" (5.1 cm) height Diameter: 4.1" (10.4 cm) installed in the B501 base Dimensions: 6.1" (15.5 cm) installed in the B21OLP base Shipping Weight: 5.2 oz. (147 g) Operating ASD-PL2F: Temperature: 32° F to 120° F (0° C to 49° C) 621OLPBP ASD-PTL2F: Dimensions: 32° F to 100° F (0° C to 38° C) UO -Listed 0-4000 ft./min. (1,219.2 m/min.), Velocity Range: suitable for installation in ducts. Relative (resistive). Humidity: 10-93% (non -condensing) Thermal Ratings: Fixed -temperature setpoint 135° F (57° C) Electrical Specifications Voltage Range: 15 - 32 volts DC peak Standby Current: (max. avg.):.0003 A @ 24 VDC (One communication every 5 seconds with LED blink enabled). Maximum Alarm - Current: .0065 A @ 24 VDC (LED) lit). Bases and Options 8501 Plug-in sensor base without flange Dimensions: 4.1" 10.4 cm diameter 621OLP Flanged mounting base Dimensions: 6.1" (15.5 cm) diameter 621OLPBP Flanged mounting base bulk pack Dimensions: 6.1" (15.5 cm) diameter B224RB Plug-in sensor base with auxiliary Relay Base relay, SPDT, rated 2 amps @ 30 VDC (resistive). Screw terminals: Up to 14 AWG (2.0 mm2) 2 coil latching relay 1 Form C contact UL/CSA Rating: 0.9 A @ 125 VAC, inductive 0.9 A@ 110 VDC, inductive 3 A @ 30 VDC, resistive Dimensions: 6.1" (15.5 cm) diameter Maximum: 25 devices between isolator bases. B200S Intelligent sensor sounder base Dimensions: 6.875" (17.5 cm) diameter B200SR Standard sounder base, UL 8649th Edition compliant, ULC Listed Dimensions: 6.875" (17.5 cm) diameter RA10OZ Remote LED Annunciator BCK-200 Black detector covers (box of 10) DNR Duct smoke housing GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0617 Rev. J page 2 of 2 www.gamewell-fci.com ^Gamewell a INS CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI Velociti® Series, addressable plug-in thermal sensors with integral communication provide fea- tures that surpass conventional sensors. Point ID capabil- ity allows each sensor's address to be set, providing exact locations for pinpointing alarm locations and for selective maintenance. ATD thermal sensors use an innovative thermistor sensing circuit to produce 135°F/57°C fixed - temperature (ATD-1_21F). The ATD-RL2F provides a combi- nation 15°/minute rate -of -rise with 135° fixed thermal detection that is included in a low -profile package. The ATD-HL2F provides fixed high-temperature detection at 190°F/88°C. These thermal sensors provide cost-effective, addressable property protection in a variety of applica- tions. The Velociti® Series uses a communication protocol that substantially increases the speed of communication between the sensors and Gamewell-FCI analog address- able fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and identifies the single device with the status change. The net effect is response speed up to five times greater than earlier designs. Installation ATD plug-in sensors use a separate base to simplify instal- lation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: • 4.0" (10.2 cm) square box. • 3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box. • Single -gang box (except relay or isolator base). • With B200S or B200SR base, mounted on a 4.0" (10.2 cm) octagonal or square box. • With B224RB or B224BI base, mounted on a 3.5" (8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or square box. NOTE: Because of the inherent supervision provided by the SLC, end -of -line resistors are not required. Wring "T - taps" or branches are permitted for Style 4 (Class "B") wiring. Velocib'®and E3 Series® are registered trademarks of Honeywell Intemabonal Inc. UL® is a registered trademark of Underwriters Laboratories Inc. ULC® is a registered trademark of Underwriters Laboratories Canada Inc. Velociti° Series ATD-L2F, AT13-11,2F Addressable Thermal Sensor ATD-L2F Features • Sleek, low -profile design • Visual rotary switch addressing • Built-in functional test switch activated by an external magnet • Bicolor LEDs Flash green whenever the sensor is addressed, and light steadily red on alarm* • Optional relay, isolator, or sounder bases • Low standby current • Addressable communication • Stable communication technique with noise immunity • Optional remote, single -gang LED accessory (RA -100Z) Suitable for installation in ducts Note: *Only the red LED is operative in panels that do not operate in Velociti® mode. An ISO 9001-2000 Company SIGNALING & FM MEA LISTEB Approved 30235 52332 10236944 119.01•E VoI.VI 7270.1703:0115 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specific,' ens are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. [02011 by Homp'A International Inc. All rights reserved. www.gamewell-fcLCom 9020-0620 Rev. E page 7 of 2 i Specifications ATD-L2F/ATD-RL2F Dimensions: Shipping Weight: Operating Temperature: ATD-L2F or ATD-RL2F ATD-HL2 Sensor Spacing: Relative Humidity: ATD-L2F ATD-RL2F ATD-HL2F 2.1" (5.3 cm) Height 4.1" (10.4 cm) diameter installed in the B501 base 6.1" (15.5 cm) diameter installed in the B21 OLP base 4.8 oz. (137 g) —4° F to 100° F (-20° C to 38°C) —4° F to 150°F (-20 C to 66°C) UL® approved for 50 ft. (15.2 m) center to center FM approved for 25 x 25 ft. (7.6 x 7.6 m) spacing 10 — 93% (non -condensing) Fixed -temperature setpoint 135-F (57-C) Combination 135° F fixed temperature and 15° F(8.3°c)/per minute rate -of -rise* Fixed -temperature setpoint 190-F (88°C) Electrical Specifications Voltage Range: 15 - 32 Volts DC peak Standby Current: 200 mA @ 24 VDC (without communication) (max. avg.) .0003 A @ 24 VDC (one communication every 5 seconds with LED blink enabled) LED Current (max.) .0065 A @ 24 VDC (LED lit) Specifications Bases and Options 8501 Plug-in sensor base without flange Dimensions: 4.1" 10.4 cm diameter B21 OLP Flanged mounting base Dimensions: 6.1" 15.5cm diameter 6.1" (15.5 cm) diameter B21OLPBP Flanged mounting base bulk pack Dimensions: 6.1" (15.5 cm) diameter B224RB Plug-in sensor base with auxiliary relay, SPDT 2 coil latching relay 1 Form C contact UL/ Ordering Information Part Number Description ATD-L2F Addressable thermal sensor, fixed, 135' F IATD-RL2F Addressable thermal sensor, combination fixed.135° F and 15°/minute rate -of -rise. ATD-HL2F Addressable thermal sensor, fixed, 190' F GAMEWELL-FCI 12 Clintonville Road, Nonhford, CT 06472-1610 USA • Tel: (203) 464-7161 • Fax: (203) 484-7118 9020-0620 Rev. E page 2 of 2 www.gamewell-fci.com CSA Rating: 0.9 A @ 125 VAC (inductive) 0.9 @ 110 VDC (inductive) 3.A @ 30 VDC (resistive) Dimensions: 6.1" (15.5 cm) diameter B224BI Plug-in sensor isolator base for Style 7 operation Dimensions: 6.1" (15.5 cm) diameter Maximum 25 devices between isolator bases B200S Intelligent sensor sounder base Dimensions: 6.875" (17.5 cm) diameter B200SR Standard sounder base, UL 864 9th Edition compliant, ULC Listed Dimensions: 6.875" (17.5 cm) diameter RA -100Z Remote LED Annunciator BCK-200 Black detector covers (box of 10) Ordering Information Part Number Description ATD-L2F Addressable thermal sensor, fixed, 135' F IATD-RL2F Addressable thermal sensor, combination fixed.135° F and 15°/minute rate -of -rise. ATD-HL2F Addressable thermal sensor, fixed, 190' F GAMEWELL-FCI 12 Clintonville Road, Nonhford, CT 06472-1610 USA • Tel: (203) 464-7161 • Fax: (203) 484-7118 9020-0620 Rev. E page 2 of 2 www.gamewell-fci.com ^Gamewell aNSS'TRUUMENTS by Honeywell Description The Gamewell-FCI, MS -7 Series manual fire alarm sta- tions are available in a wide variety of configurations. The Stations comply with the Americans with Disabilities Act (ADA) 5 -Ib. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All stations have a key look/reset which is keyed alike with Gamewell-FCI fire alarm control panels and other manual fire alarm stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti® Series addressable station is a dou- ble action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The sta- tion features screw terminals. MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable station is a single action station designed for installation in the signal- ing line circuit of Gamewell-FCI analog addressable con- trol panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The sta- tion features screw terminals. The Velociti® Series stations use a communication proto- col that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and focuses on the single device. The net effect is response speed up to five times greater than earlier designs. MS -7 Double Action Station The MS -7 double action station is used with conventional fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. Velocibdt' is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriter's Laboratories Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. MS -7 Series Non -Coded, Manual Fire Alarm Stations MS -7 Features • Addressable stations compatible with all Gamewell-FCI analog addressable fire alarm controls • Conventional stations suitable for use with any UL® Listed control panel • Both single and double action stations available • Tumbler lock for test and reset keyed alike with Ganr ll-FCI controls • Surface or semi -flush mounting • Shock and vibration resistant • Stations (MS-7LOB) Listed for outdoor applications • Complies with ADA pull force requirements *Only the red LED is operative in panels that do not oper- ate in Velociti mode. SIGNALING &FM LISTED $2465 APPROVED Mi 3023694 67.02-EVOLM11 7160-1703:0119 7160-1703:0170 7160-1703:0109 1S09001 GAMEWELL-FCI ••°°° °••�°•° 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 • SpecNcations are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCl for their use. 02013by Honeywell Intemational Inc. All rights reserved. www.gamewell-fel.com 9020-0616 Rev. E page 1 of 2 MS -7S Single Action Station The MS -7S single action station is used with conventional fire alarm control panels. It features a set of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action station similar to the MS -7 station, with the additional feature of both English and Spanish instructions molded into the unit. MS-7LR Dual -action Agent Release Station The MS-7LR is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems. It features a set of single pole contacts and screw terminals for connection to an ini- tiating circuit. MS-7LRA Agent Release Station with Abort The MS-7LRA is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabil- ities are required. It consists of an MS-7LR mounted on a plate with an abort switch and LED indicators for system normal, and system activated status. MS-7LOB Double Action Station (Listed for Outdoor Applications) The MS -71_06 station must be mounted on a Model SB -1/0 backbox. In retrofit applications, the station is UL Listed for use with the WP -10 backbox. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS -7 interior stations may be surface mounted or semi -flush mounted on a standard double -gang, or 4 -inch (10.2 cm) square electrical box. An optional trim ring (BG12TR) may also be used for semi -flush mounting. NYC -Plate The NYC -Plate provides the backplate for the manual pull station. (See Figure 1). Figure 1 NYC -Plate Specifications Material: Lexan® Contact Ratings: 0.25 amps. @ 30 VACNDC MS-7AF** (resistive) Dimensions: 5 5/8" H x 4 1/4" W x 1 1/4" D station (14 x 10. 1 x 3.2 cm) Operating Temperature Velociti addressable single action station (MS-7AF, MS-7ASF): 32° to 120° F (0° to 49° C) (MS-71LOB): -30° to 150° F (-35° to 66° C) Relative Humidity Spanish instructions (MS-7AF, MS-7ASF): 10 to 93% (non -condensing) (MS-7LOB): 85% t 5% @ 86° t 3.60 (300 t 2° C) Alarm Current: .0030 amp. 0.007 for LED Supervisory Current (Includes SB -1/0 - Indoor/outdoor use (MS-7AF, MS-7ASF): .00030 amps. Ordering Information Part Number Description MS -7 Double action station MS-7AF** Velociti addressable double action station MS-7ASF** Velociti addressable single action station MS -7S Single action station, wire leads MS-7SP Double action station, English and Spanish instructions MS-7LR Agent release station, dual -action MS-7LRA Agent release station with abort switch, LED indicators, dual- action MS-7LOB Double action station, outdoor use (Includes SB -1/0 - Indoor/outdoor use backbox) SB -110 Indoor/outdoor use backbackbox SB -10 Surface backbox BG12TR Trim ring for semi -flush mount, plastic NY -PLATE NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. GAMEWELL-FCI 12 Clintonville Road, Northford. CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 \9020-0616 Rev. E page 2 of 2 www.gamewell-fci.com J ^Gamewell Q FIRECONTROL ® INSTRUMENTS by Honeywell Description The lnnovairFleXTM Series, DNR intelligent, non -relay pho- toelectric duct smoke detector, and the DNRW watertight, non -relay photoelectric duct smoke detector feature a piv- oting housing that fits both square and rectangular foot- prints. These detectors are capable of mounting to a round or rectangular duct. The DNR/DNRW detectors can be used with the E3 Series®and 7100 Series Systems. Note: The InnovairFlex TM Series, DNR requires the Veloc- iti® Series, ASD-PL2FR Sensor and AOM-2RF, if relays are required for the fan control. The DNRW duct smoke detector, with its NEMA 4 rating, is Listed as a watertight enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water. These features allow operators to use the detector in the most extreme environments. The units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of -4°F to 158°F, and a humidity range of 0 to 95 percent (non -condensing). An improved cover design isolates the sensor head from the low -flow feature for simple maintenance. A cover tam- per feature was added to indicate a trouble signal for a removed or improperly installed sensor cover. The InnovairFlex housing provides a 3/4 -inch conduit knockout and ample space to facilitate easy wiring and mounting of the relay module. The InnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories. WARNING:Duct smoke detectors have specific limitations. DUCT SMOKE DETECTORS ARE: NOT a substitute for an open area smoke detector, NOT a substitute for early warning detection, and NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional duct smoke detector 2911 application information. E3 Series®and Velocitie are registered trademarks and InnovairFlexTe is a trademark of Honeywell International, Inc. UL®is a registered trademark of underwriters Laboratories Inc. Innoselffiffl " Series DNR/DNRW Duct Smoke Housing Intelligent Non -Relay Photoelectric Duct Smoke Housinq InnovairFlex-DNRIDNRW Features • Photoelectric, integrated low -flow technology • Air velocity rating from 100 ft/min to 4,000ft/min (0.5m/s to 20.32m/sec) • Versatile mounting options: square or rectangular configuration • Broad ranges for operating temperature (-4°F to 1587) and humidity (0% to 95% non -condensing) • Patented sampling tube installs from front or back of the detector with no tools required • New Cover tamper signal • Increased wiring space with a newly added 3/4 -inch conduit knockout • Available space within housing to accommodate the mounting of the relay module • Easily accessible code wheels on sensor head (sold separately) Clear cover for convenient visual inspection • UL®268AListed • Remote testing capability • Requires SLC line power only • NEMA Type 4 UL Listed for non -hazardous indoor and outdoor applications (DNRW only) • UV Resistant, UL®Listed housing and cover material (DNRW only) SIGNALING UL <S>MSFM @LISTED 11 APPROVED 2202 S911 3029700 2207 7272-1703:0121 S911 ISS - GAMEWELL-FCI 12 Clintonville Road, forthford, Cur 06472-1610s,andasubject USA •Tel: (203) 4&4-7161.Nore •Fax: (203) 464-7118 '•••••• Spec�catbns are for information only, are rmt intended for installation purposes, and are suDJea to change without notice. No responsibility is assumed by GamewelbFClfor their use. 02013 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60475 Rev. E page 1 of Architectural/Engineering Specifications The air duct smoke detector shall be a System Sensor InnovairFlexTm DNR Intelligent Non -Relay Photoelectric Duct Smoke Detector and DNRW Watertight NEMA4 Duct Smoke Detector. The detector housing shall be LIL Listed per LIL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 ft/min to 4,000 ft/min (0.5 m/sec to 20.32 m/ sec). The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS151KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Physical Specifications Size: Rectangular Dimensions: 14.38 in (37 cm) Length; 5 in (12.7 cm) Width; 2.5 in (6.6 cm) Depth Square Dimensions: 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 Ib (0.73 kg) Environmental Rating: NEMA4 (DNRW only) Operating Temperature Range: —40 to 158°F(-200to 70°C) Storage Temperature Range: —220 to 158°F(-300to 70°C) Operating Humidity Range: 0% to 95% relative humidity non -condensing Air Duct Velocity: 100 to 4000 it/min (0.5 to 20.32 m/sec) DCOIL - (if included) 17.5 - 26.4 VDC .95mA max. Electrical Ratings For information on the electrical specifications, refer to the InnovairFlex DNR Duct Smoke Detector Installation Instructions, P/N 156-3051-001R. Accessory Current Loads at 24 VDC Device Standby Trouble RA100Z 0 mA 12 mA Max. RTS151/RTS151KEY 0 mA 12 mA Max. Installing the InnovairFlex Sampling Tube The InnovairFlex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab. (Figure 3 illustrates the front locking tab). Figure 1 Figure 2 Figure 3 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60475 Rev. E page 2 of 4 www.gamewell-fci.com J Wiring for Intelligent Non -Relay Duct Smoke Detector Figure 4 System Wiring Diagram for DNR DNR TO RTS451/RTS451 KEY/RTS1511 RTS151KEY WITH'R" REMOTE TEST CAPABLE DETECTOR HEAD OPTION: TEST COIL +I I CO MM. T* ryy{{�+ I LINE (+) COMM. I I 1 PER UNIT LINE I I S5AWFRNTDPAI I Key I + I I LINE (L.) T� I j I UUFM LISTED 1ST 2ND CONTROL DETECTOR DETECTOR PANEL IN LOOP IN LOOP Figure 4 System Wiring Diagram for DNR DNR TO RTS451/RTS451 KEY/RTS1511 RTS151KEY WITH'R" REMOTE TEST CAPABLE DETECTOR HEAD OPTION: TEST COIL +I MRTS - RA10OZ REMOTE ALARM LED OPTION 1 PER UNIT Figure 5 DNR to RA100Z RTS451/RTS4511EY TEST COIL+ RTS151/RTS151 KEY TEST COIL • COMM + ® RST OUi (CONN ONLY) + FF n. ,,,•-••, _ RT151IRTS151KEY JUMPER RA+� 00',.nn ryy{{�+ -j MRTS - RA10OZ REMOTE ALARM LED OPTION 1 PER UNIT Figure 5 DNR to RA100Z RTS451/RTS4511EY TEST COIL+ RTS151/RTS151 KEY TEST COIL • COMM + ® RST OUi (CONN ONLY) + FF n. ,,,•-••, _ RT151IRTS151KEY JUMPER RA+� �OO�oN 1 PER UNIT ryy{{�+ -j TESTCDILOPn0N 1 PER UNIT S5AWFRNTDPAI Figure 6 DNR to RTS1511RTS151 Key - - -- - -- _ Important Notes: • The use of either RTS151 or RTS151 KEY requires the installation of an accessory coil, DCOIL, sold separately. For additional information, refer to the DNR or DNRW Duct Smoke Detector Installation Instructions, P/N 156-3051-001R and the Duct Application Smoke Detectors Application Guide. • The RTS151/RTS151KEY test coil circuit requires an external 24 VDC power supply which must be UL Listed. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60475 Rev. E page 3 of 4 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accesso- ries are LIL Listed. Ordering Information Part Number Descriptior DNRW Watertight intelligent non -relay photoelectric low -flow duct smoke detector ASD-PL2FR Intelligent photoelectric smoke sensor with remote test capability in duct applications Accessories Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m) Part Number Description DCOIL Remove test coil required with RTS151/RTS151151 KEY DST1 Metal sampling tube duct width up to 1 ft (0.3m) DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST3 Metal samolina tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) Remote test station with key lock 7ti 7i.._1 i li Figure 7 RTS151 UL S2522 Figure 8 RTS151 KEY UL Figure 9 RA10OZ UL S2522 Figure 10 ASD-PL2FR S2522 Ordering Information Part Number Descriptior DNRW Watertight intelligent non -relay photoelectric low -flow duct smoke detector ASD-PL2FR Intelligent photoelectric smoke sensor with remote test capability in duct applications Accessories Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m) Part Number Description DCOIL Remove test coil required with RTS151/RTS151151 KEY DST1 Metal sampling tube duct width up to 1 ft (0.3m) DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST3 Metal samolina tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) DST10 Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m) DH4000E-1 Weatherproof enclosure ETX Metal exhaust tube duct width 1 f (0.3m) M02-04-00 Test magnet P48-21-00 End cap for metal sampling tubes RA100Z/RA100ZA Remote annunciator alarm LED RTS151 Remote test station RTS151 KEY Remote test station with key lock GAME -TCI 12 Clintonville Road, Northford, CT 06472-1610D USA USA •Tel: (203) 484-7161 •Fax: (203) 484-7118 9021-60475 Rev. E page 4 of 4 www.gamewell-fcl.com ^Gamewell ROL FRINSTRUMENTS S by Honeywell Description The Gamewell-FCI Velociti® Series, addressable monitor module (AMM -4F) features a single Style D, Class A initiat- ing device circuit. It may also be configured as a Style B, Class B initiating circuit with end -of -line resistor. This mod- ule provides an address for any device or group of devices connected to this circuit. Any alarm initiating devices with normally open (N.O.) dry contacts, such as heat detectors, linear heat detection devices, 4 -wire projected beam smoke detectors, 4 -wire smoke detectors, water flow switches, tamper switches, manual stations, etc. may be installed in this circuit. The Velociti® Series use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The AMM -4F module is designed for installation in the Sig- naling line circuit of any Gamewell-FCI analog addressable control panel. The initiating circuit of the AMM -4F has a maximum line resistance of 40 ohms, allowing the module to accommodate a number of initiating devices at a dis- tance from the module. The AMM -4F is designed to mount in a 4" square junction box 2 1/8" deep. The initiating device circuit of the AMM -4F can support a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. Ordering Information Model Description AMM -0F Addressable monitor module, single circuit, Style D Class A or Style BC/A and B VelocibI8 and E3 Sedesa are registered trademarks of Honeywell Internalkonal Inc. Veloeit=@ Series AMM,4F Addressable Monitor Module AMMAF Features Compact size allows easy installation • Class A, Style D, or Class B, Style B initiating circuit • Visual rotary, decimal switch addressing (01-159) • 40 ohm line resistance for each initiating device circuit • Accommodates any N/O dry contact device • Bicolor LEDs flash green whenever the module is addressed, and light steady red on alarm' 'Note: Only the red LED is operative in panels that do not operate in Velociti® mode. Specifications Supervisory current: Alarm current: Operating temperature: Relative humidity: End -of -line resistor: Dimensions: .000375 amps. (LED flashing) .005 amps. (LED lit) 32° to 120° F (0° to 49' C) 10 to 93% (non -condensing) 47Kohms 4 1/2" H x 4" W x 1 1/4" D (11.4x10.2x3.2cm) aiceauMo & <FM> MEA LISTED APPROVED S1949 3023594 227-03-E Vol. IV 7300-1703:0102 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. onwywell International Inc. Allrghtsfeserved. www.gamewell-fci.com 9020-0624 Rev. E page 1 of 1 ^Gamewell a INSSTRRUUMEt by Honeywell Description The Gamewell-FCI Velociti® Series, addressable output relay control module (AOM-2RF) allows an Gamewell-FCI analog addressable fire alarm control to switch discrete relay contacts by code command. The relay provides two (2), isolated sets of Form -C contacts which transfer simul- taneously. Circuit connections to the relay contacts are not supervised by the module. The Velociti® Series use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The AOM-2RF Module is designed for installation in the signaling line circuit of any Gamewell-FCI analog address- able fire control panel. The module contains a panel con- trolled LED. The AOM-2RF is designed to mount in a 4" square junction box 2 1/8" deep. Relay Contact Ratings Current Rating Maximum Voltage Load Description Application 3A 30 VDC Resistive Non -Coded 2A 30 VDC Resistive Coded 0.9A 110 VDC Resistive Non -Coded 0.5A 125 VAC Resistive Non -Coded 0.5A 30 VDC Inductive (UR=5ms) Coded 1A 30 VDC Inductive (UR=2ms) Coded =0.7A; Inductive (PF=.35) Non -Coded Inductive Non -Coded Velociti® Series is a registered trademark of Honeywell International Inc. V010ci118 series AOM -21F Addressable Output Relay Control Module A0M-2RF Features • Two (2) sets of Form "C" contacts • Visual rotary, decimal switch addressing (01-159) • Bicolor LEDs Flash green whenever the sensor is addressed, and light steady red on alarm* • Compact size allows easy installation Note: Only the red LED is operative in panels that do not operate in Velociti® mode. Specifications Supervisory current: Alarm current: Operating temperature: Relative humidity: Dimensions .000375 amps. .0065 amps. 32° to 120° F (0° to 49° C) 10 to 93% relative humidity (non -condensing) 4 1/2" H x 4" W x 1 1/4" (11.4 x 10.2 x 3.2 cm) Ordering Information Model Description AOM-2RF Addressable output relay control module sicxa W U` < FM LISTED Soho Awa 9 51913 3023594 219-02-E Vol. VI 7300-1703:0102 IS 9001 � GAMEWELL-FCI °""° 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only. o e not intended for installation purposes, and are subject to charge without notice. No responsibility is assumed by Gdmewell-FOI for their use. \©2013 Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0625 Rev. E page 1 of 1 J SYSTEM SENSOR' Multi -Voltage Conventional Relays System Sensor's multi -voltage conventional relays are used for high -current switching applications such as fan and damper assembly control, door control, air handling unit controls, and other types of system interfacing. Features • Multi -voltage operation • Activation LEDs • Easy and Flexible installation • Reliable and robust design • Multipurpose field installations Multi -voltage relays with terminal strip field wiring connections, mounting track, and hardware for R-1 OT/20T and R-14T/24T Removable front cover on steel enclosure for R-10E/R-20E and R - 14/R -24E, which mount inside the enclosure LED viewing hole on top of the steel enclosure's cover Extra pair of wires for redundant power input on PR -3 Terminal strip field wiring connections, mounting track, and hardware Agency Listings aMEA LISTED The R -10T, R -20T, R-1 4T, and the R -24T models are muld- voltage relays with terminal strip field wiring connections, mounting track, and hardware.The R-1 OT is a single FORM -C (SPDT) relay with a red activation LED, and the R -14T is a four -gang 1 FORM -C (SPDT) relay with four red activation LEDs.The R -20T is a single 2 FORM -C (DPDT) relay with a red activation LED, and the R -24T is a four -gang 2 FORM -C (DPDT) relay with four red activation LEDs. The R-t0E/R-20E and R-14E/R-24E are similar to the T -series track mount relays, but they are mounted into a steel enclosure.The enclosure has a removable front cover that provides easy access and an LED viewing hole on the top of the cover. PR -1 /PR-2/PR-3 are epoxy encapsulated multi -voltage relays. They are single -pole double -throw relays that use a red LED as a visible indication of relay coil energization. PR -3 is identical to PR -2, except it has an extra pair of wires for redundant power input. Model EOLR-1 is an epoxy encapsulated, single -pole single -throw, - -- normally open relay that can be used as an end of line device in fire alarm systems, e.g. to supervise power supplies. Multi -Voltage Conventional Relay Specifications Operating Voltage 18-35VDC, 18- 35VAC, 115VAC, 230VAC Operating Current 20 mA DC max.@ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-IOT/R-14T) 40 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-20T/R-24T) Operating Temperature -40°F to 158°F (-40°C to 70°Q Humidity Range 10% - 93% non -condensing Dimensions R-lOT/R-20T: 2.51 x 3.35W x ITH Operating Temperature R-14T/R-24T: 101 x 3.35 W x 1.2'H Contact Ratings 24 VDC:7 Awith VR=5 mS Operating Temperature 120 VAC 10 A Humidity Range 120VAC:1 /6 HP Dimensions 230 VAC: 7 A Operating Voltage 18-35 VDC, 18- 35 VAC 115 VAC, 230VAC Operating Current 20 mA DC max.@ 24VDC, 24VAC, 115 VAC, Operating Current 230 VAC (R-10E/R-1 4E) Operating Temperature 40 mA DC max. @ 24 VDC, 24VAC, 115 VAC, Humidity Range 230 VAC (R-20E/R-24E) Operating Temperature -40°F to 158°F (-40°C to 70°Q Humidity Range 10% - 93% non -condensing Dimensions R-10E/R-20E: 5.11 x 3.75W x 2. SH Humidity Range R-14E/R-24E:111 x 53W x 2.5H Contact Ratings 24 VDC: 7 A with L/R=5 mS 120 VAC 10 A 120VAC: 1/6 HP 230VAC:7 A Operating Voltage 10 to 40VDC Specifications: PRA Operating Voltage 18-35 VDC, 18-35 VAC, 120VAC Operating Current 15 mA DC max.@ 24 VDC, 24 VAC, 120VAC Operating Temperature -40°F to 158°F (-40°C to 70°Q Humidity Range 10-93%RH Wire Length 8 -minimum Dimensions 0.87'H x 2.01'W x 1.42D Contact Ratings 24 VDC:7 Awith VR=5 mS 120VAC: 7 A max. (0.35 PF) 250VAC: 10 A resistive 30 VDC: 10 A resistive Operating Voltage 10 to 40VDC Operating Current 30 mA DC max. Operating Temperature -40°F to 158°F (-40°C to 70°Q Humidity Ranae 10-93%RH 8"minimum Dimensions 0.91'H x 165 W x 1.22D Contact Ratings 120 VAC: 10 A max. (resistive load) 120VAC: 7 A max. (0.35 PH 250VAC: 10 A max. (resistive load) 30VDC: 10 A max. (resistive load) Operating Voltage 9 t 40VDC Operating Current 20 mA DC max. Operating Temperature -22°F to 140°F( -30°C to 60°Q Humidity Range 10-93%RH Wire Length 8 -minimum Contact Ratings 120 VAC: 0.5 A max. (resistive load) 30VDC:3 A max. (resistive load) PR I LUI R 1 Ph 3 R -10E & R -20E Enclosure FR 2 R -10T R -14T R-1 4E & R -24E Enclosure SYSTEM 3825Ohio Avenue •St.Charles, IL 60174 nar SENSOR Phone: 800-SENSOR2•Fax: 630-377-6495 ""` t_' W t6 `— d- aoso372ws var i2e2 SYSTEM SENSOR Indoor Selectable Output Speaker Strobes and Dual Voltage Evacuation Speakers The new SpectrAlert'Advonce selectable output speaker strobes and dual evacuation speakers can reduce ground faults and allow faster installation. Features Plug-in design Protective cover isolates speaker components, reduces ground faults Electrical compatibility with existing SpectrAlert products Field selectable candela settings on wall and ceiling units: Standard: 15, 15/75, 30, 75, 95, 110, 115 High: 135, 150, 177, 185 Shorting spring on mounting plate tests continuity before installation Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings ('/4, V2, 1 and 2 watts) Universal mounting plate for wall- and ceiling -mount units Compatible with System Sensor synchronization protocol SP speakers offer high fidelity sound output SPV speakers offer high volume sound output Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela • No extension ring required •Ceiling and wall mount application •Optional tamper resistantTorx head screw included Agency Listings SIGIMIMG UL ® Fv MFA LISTED approved 7111IM2m 1M8E S t , n, S e P, s o mr The SpectrAlert Advance Series of speakers and speaker strobes is designed to reduce ground faults.The plug-in design allows the installer to pre -wire mounting plates and dress the wires before plugging in the speakers.The plastic cover prevents nicked wires by covering exposed speaker components. This design also allows faster installations with instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 11 field selectable candela settings for wall and ceiling speaker strobes. The low total harmonic distortion of the SP speaker offers high fidelity sound output while the SPV speaker offers high volume sound output for use in high ambient noise applications. SpectrAlert Advance makes installation easy • Attach a universal mounting plate to a 4 x 4 x 2'/e inch back box. Flush mount applications are achievable without the need for an extension ring. • Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. • Attach the speaker or speaker strobe to the mounting plate by inserting the producttabs into the mounting plate grooves. Rotate the device into position to lockthe product pins into the mounting plate terminals.The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. Advance Speaker and Speaker Strobe General SpectrAlert Advance speaker and speaker strobes shall mount to a 4 x 4 x 2'/s -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes, when used with the Sync -Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlen Advance products shall operate between 32°F and 120°F from a regulated DC, or full -wave rectified, unfiltered power supply. Speaker strobes shall have field -selectable candela settings including 15,15/75, 3Q 75, 95, 110, 115,135, 150,177,185. Speaker The speaker shall be a System Sensor SpectrAlert Advance model dual -voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4000 Hz and shall have an operating temperature between 32°F and 120T.. Speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor SpectrAlert Advance model listed to UL 1480 and UL 1471 and be approved For fire protective signaling systems. Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4000 Hz. Speaker shall have power taps which are selected by rotary switch. The strobe shall complywith the NFPA72 requirements forvisible signaling appliances, Flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon Flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL listed to UL464 and shall be approved for fire protective service. -The module shall synchronize SpectrAlert strobes at 1 Hz.The module shall mount to a 411/16 x 41'/m x 2'/e -inch back box.The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Operating Temperature 32°F to 120'F (OC to 49°C) Humidity Range 10 to 93% non -condensing Dimensions, Wall -Mount 6.8 in Dia. x 2.8 in D SPS Speaker Strobe 6.0 in L x 5.0 in W x 4.7 in D (including lens and speaker) SPSV Speaker Strobe 6.0 in L x 5.0 in W x 4.9 in D (including lens and speaker) SP Speaker 6.0 in L x 5.0 in W x 2.8 in SPSV Sneaker 6.0 in L x 5.0 in W x 2.9 in D SPS Speaker Strobe 6.8 in Dia. x 4.7 in D (including lens and speaker) SPSV Speaker Strobe 6.8 in Dia. x4.8 in D (including lens and speaker) SP Speaker 6.8 in Dia. x 2.8 in D SPV Speaker 6.8 in Dia. x 2.9 in D Electrical/Operating Specifications Nominal Voltage (speakers) 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage(speakers) 50VDC Strobe Flash Rate 1 Flash per second Nominal Voltage (strobes) Regulated 12 VDC/FWR or regulated 24 DC/`WR Operating Voltage Range (includes fire alarm panels with built In sync) 8 t 17.5V(12 V nominal) or 16 to 33V(24V nominal) Operating Voltage with MDL Sync Module 9 t 17.5V(12 V nominal) or 17 to 33V (24V nominal) Frequency Range 400 to 4000 Hz Power '/a'/e, t, 2 watts UL Current Draw Data I L Max. Strobe Current r NA NA 158 153 95 8 to 17.5 Volts NA 16 to 33 Volts 176 Candela DC FWR DC FWR Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Sound Output UL Reverberant (dBA @ 10 k.) 2W I 1/2W V4W Wall -Mount SP Series 86 83 80 77 Wall -Mount SPV Series 90 87 84 81 Ceiling -Mount SPC Series 86 83 80 77 Ceiling -Mount SPCV Series 90 87 84 81 Wall -Mount SPS Series 85 82 79 76 Wall -Mount SPSV Series 89 86 83 80 Ceiling -Mount SPSC Series 85 82 79 76 Ceiling -Mount SPSCV Series 89 86 83 80 Ceiling Mount SPV Speaker Ceiling Mount SP Speaker Wall Mount SP Speaker IN Ceiling Mount SPS Speaker Strobe Wall Mount SPS Speaker Strobe Surface Mounting Ceiling Mount Speaker with SPBBSCW Back Box Skirt Wall Mount Speaker Strobe with SPBBS Back Box Skirt Ordering Information for SpectrAlert* Advance Speakers and Speaker Strobes White Red SPW SPR SPWV SPRV Speaker only, High d8 SPSW* SPSR* _ _ Speaker Strobe, Selectable Candela(15,15/75, 3Q 75,95,110,115) SPSWH* SPSRH* Speaker Strobe, Selectable Candela, High cd (135,150,177, 185) SPSWV* SPSRV* Speaker Strobe, Selectable Candela (15,15/75,30,75,95,110,115), High dB White Red Description $PCW _ SPCR Speakeronly SPCWV SPCRV Speaker only, High d6 SPSCW* SPSCR Speaker Strobe, Selectable Candela (1 5,15/75,3Q 50,75,95,110,115) SPSCWH' SPSCRH Speaker Strobe, Selectable Candela, High cd (135,150,177,185) SPSCWV* SPSCRV Speaker Strobe, Selectable Candela (15,15/75,30,75, 95,110,115), High dB SPSCWVH` SPSCRVH Speaker Strobe, Selectable Candela, High dB, High cd (135,150,177,185) White Red Description RFPW RFP 7 in x 95 in Retrofit Plate Ceiling Mount Back Box Skirt Wall Mount Back Box Skirt TR Wall TRCW TRC Ceiling Mount Trim Ring ^ Add -P to model number for plain housing (no'FIRE' marking on the cover) e.g. SPSW-P SYSTEM 38250hio Avenue • St. Charles, 1160174 noe,�,pKrt.,e�m::�gm,oca�e.�ixv, ���e vv.n„��,.ro•,,r, SENSOR- Phone: 800-SENSOR2• Fax: 630-377-6495 `'r—tcrm`nro„mua iziw� la ego ,ati' a a A. 2a .2 51N rr. SYSTEM SENSOR% Outdoor, Selectable - Output Speaker Strobes and Dual -Voltage Evacuation Speakers SpectrAlert' Advance outdoor, selectable -output speaker strobes and dual -voltage evacuation speakers meet virtually any outdoor application requirement. Features The SpectrAlert Advance series offers the broadest line of • Plug-in design outdoor speakers and speaker strobes in the industry. From metal and plastic outdoor back boxes, to white and red plastic housings, to • Electrical compatibility with legacy SpectrAlert products wall and ceiling mounting options, SpectrAlert Advance can meet •Shorting spring onmounting plate tests continuity before virtually any application requirement. installation on the back of the back box eliminate the need to drill holes for • Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (1/4, 1h, 1 and 2 watts) • Ceiling- and wall -mount application Universal mounting plate for wall- and ceiling -mount units • Weatherproof per NEMA 4X, IP56 •Compatible with System Sensor synchronization protocol • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela Field -selectable candela settings on wall and ceiling units SpectrAlert Advance outdoor speakers and speaker strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from —40"F to 1517.. In addition, these speakers provide a broad frequency response range, low harmonic distortion and maintain a high sound pressure level at all tap settings to provide accurate and intelligible broadcast of evacuation messages. The entire SpectrAlert Advance line, including speakers, provides a plug-in design that reduces ground faults by enabling installers to pre -wire mounting plates and dress the wires before plugging in the speakers.To enable faster installation times, a shorting spring on the mounting plate provides instant feedbacktoensure that wiring _-- is properly connected. Furthermore, rotary switches simplify the selection of voltage and power settings. Both wall and ceiling speaker strobes include field-selectablecandelasettingsthatenableinstallers --- to quickly set each device to meet application requirements. The speakers'weatherproof plastic back boxes (shipped with product) and metal back boxes (available separately) are designed to accommodate in -and -out wiring for daisy chaining outdoor devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion.The screw -hole knock -outs located Agency Listings on the back of the back box eliminate the need to drill holes for rasnsw screw-in mounting. Both weatherproof back boxes come with NU 3/4-inch top and bottom conduit entries and 3/4 -inch knock -outs at urree approved the back. Included with each back box is a screw-in NPT plug with an 75W 73ro-IM201 111E 0 -ring gasket for a water tight seal. SpectrAlert® Advance Outdoor Speaker and Speaker Strobe General SpectrAlert Advance outdoor speakers and speaker strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes, when used with the SyncCircuit Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12 -volt -rated notification appliance circuit outputs shall operate between 9 and 17.5 volts, 24 -volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -407 and 151°F from a regulated DC, or full -wave rectified, unfiltered power supply. Speaker Speaker shall be a System Sensor SpectrAlert Advance Model dual -voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. Speaker shall be fisted to Underwriters Laboratories Standard S4048 for outdoor fire protective signaling systems. Speaker shall have a frequency range of 400 to 4000 Hz and shall have an operating temperature from -407 to 150.87.. Speaker shall have power taps and wattage settings that are selected by rotary switches. The speaker must be installed with its weatherproof back box in order to remain outdoor approved per UL listing S4048.The speaker shall be suitable for use in air handling spaces and wet environments. Speaker Strobe Combination The speaker strobe shall be a System Sensor Model listed to UL 1638 and UL 1480 and be approved for fire protective signaling systems. Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms and shall have a frequency range of 400 to 4000 Hz. Speaker shall have power taps that are selected by rotary switch. The strobe shall consist of a xenon Rash tube with associated lens/reflector system and operate on either 12 or 24 volts. The strobe shall also feature selectable candela output, providing options for 15 or 15/75 candela when operating on 12 volts and 15,15775, 30, 75,110,115,135,150,177 or 185 candela when operating on 24 volts.The strobe shall comply with the Americans with Disabilities Act requirement for visible signaling appliances, Flashing at 1 Hz over the strobe's entire operating voltage range.The speaker strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The speaker strobe shall be suitable for use in wet environments. Physical Specifications Operating Temperature -40T to 151°F (-40°C to 66"C) Dimensions, Wall -Mount SPS Speaker Strobe 6.0"L x 5.0"W x 4.7"D (including lensand speaker) SP Speaker 6.0" L x 5.0"W x 2.9"D Dimensions, Ceiling -Mount SPS Speaker Strobe 6.8" Dia. x 4.7"D (including lens and speaker) SP Speaker 6.8" Dia. x 2.9"D Dimensions, Wall -Mount Weatherproof Back Box 6.5"Lx5.5"Hx2.9"D Dimensions, Ceiling -Mount Weatherproof Back Box 7.2"Dia.x2.9"D Electrical/Operating Nominal Voltage (speakers) 25 V or 70.7 V (nominal) Maximum Supervisory Voltage(speakers) 50VDC Strobe Flash Rate 1 Flash per second Nominal Voltage (strobes) Regulated 12 VDC/F WR or regulated 24 DC/FWR Operating Voltage Range (includes fire alarm panels with built in sync) 8 t 17.5V(12 V nominal) or 16 to 33 V(24 V nominal) Operating Voltage with MDL Sync Module 9 t 17.5V(12 V nominal) or 17 to 33 V(24V nominal) Frequency Range 400 to 4000 Hz Power V4,'/2,1, 2 watts Acs -.2s xs UL Current Draw Data Candela Derating UL Max. Strobe Current Draw For K series products used at low temperatures, 8 to 17.5 Volts 16 to 33 Volts listed candela ratings must be reduced in Candela DC FWR DC FWR accordance with this table. Standard 15 123 128 66 71 '" r Candela Range 15/75 142 148 77 81 Listed Candela Candela rating at -40°F 30 NA NA 94 96 15 75 NA NA 158 153 15/75 Do not use below 32°F 95 NA NA 181 176 30 110 NA NA 202 195 75 44 115 NA NA 210 205 95 70 High 135 NA NA 228 207 110 110 Candela Range 150 NA NA 246 220 115 115 177 NA NA 281 251 135 135 185 —NA NA 286 258 150 150 177 177 Soundrutput UL Reverberant (cl @ 10 k.) 2W 1W 16W 1/41N 185 185 Outdoor Speaker 90 87 84 81 Outdoor Speaker/Strobe 89 86 83 80 7.19" PoS r � y�g8 o�'s�8t° 7.14" s888� $ 888°e "g 84 8 88 Ceiling -Mount Outdoor Speaker Wall -Mount Outdoor Speaker 7 Ceiling -Mount Outdoor Speaker Strobe Wall -Mount Outdoor Speaker Strobe AM25 Wi Surface Ceiling -Mount Speaker Strobe with Plastic Weatherproof Back Box Wall -Mount Speaker Strobe with Plastic Weatherproof Back Box b Ceiling -Mount Speaker Strobe with Metal Weatherproof Back Box .a Ceiling -Mount Speaker with Plastic Weatherproof Back Box Wall -Mount Speaker with Plastic Weatherproof Back Box Wall -Mount Speaker Strobe with Metal Weatherproof Back Box Wall -Mount Speaker with Metal Weatherproof Back Box Ordering Information for SpectrAlerto Advance Outdoor Speakers and Speaker Strobes White Red SPSWK*' SPSRK" Outdoor Speaker Strobe, Selectable Candela (15,15/75, 30, 75, 95,110,115) (includes plastic weatherproof back box) — SPSRHK Outdoor Speaker Strobe, Selectable Candela(135,150,177,185)(Includes plastic weatherproof back box) White Red Description SPCWK — Outdoor Speaker (includes plastic outdoor back box) SPSCWK — Outdoor Speaker Strobe, Selectable Candela (15,15/75,30,75,95,110,115)(includes plastic weatherproof back box) SPSCWHK — Outdoor Speaker Strobe, Selectable Candela, High cd (135,150, 177,185) (includes plastic weatherproof back box) White Accessories Red Description MWBBW MWBB Wall, Metal Weatherproof Back Box MWBBCW — Ceiling, Metal Weatherproof Back Box Notes: *Add "-R"to model number for weatherproof replacement device (no back box included), e.g., SPWK-R. Especially for use with weatherproof outdoor Flush mounting plates, WTP-SP and WTP-SPW 'Add"-P"to model number for plain housing (no"FIRE"marking on cover), e.g., SPSWK-P. � SYSTEM Z� SENSOR' 3825 Ohio Avenue•St. Charles, IL60174 c".., Phone •Fax:630-377-6495"`"'P'm'"'"r°""tl1CryMK1u'"�'"e""'""'°'"°tlar S4PL POSM]5 W5Wp9t]I89 Gamemil EEFIRE CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI, HPFF8 is a Notification Appliance Cir- cuit (NAC) expansion panel designed to extend the power capabilities of existing NACs and provide power for the auxiliary devices. The HPFF8 connects to any 12 or 24V Fire Alarm Control Panel (FACP) or stand alone. The HPFF8 is available in 8.0 amps. It provides regulated and filtered 24VDC power to each of the four NACs and an auxiliary output. The NAC outputs are rated at 3.0 amps each (the total output cannot exceed 8.0 amps). The auxil- iary output is rated at 2.0 amps. This output is continuously supplied, even in alarm, and therefore must be taken into account for power supply loading and battery size calcula- tions. The NAC outputs may be configured as any of the follow- ing: • Four Class B (Style Y) • Two Class A (Style Z) • Two Class B and one Class A • Four Class A with the optional HPP31076 Class A adapter installed These power supplies contain an internal Battery charger capable of charging up to 26.0 amp -hour (AH) batteries. The HPFF8 is mounted in lockable wall cabinet units that can accommodate up to two (2), 18AH batteries. A multi- pack option allows for up to four chassis mount units installed in a single lockable SBB-D4 enclosure. These chassis mount units have a 'CM" suffix, HPFF8CM and can accommodate two 12AH batteries. Power supplies are available in either 120VAC/60 Hz or 240VAC/50 Hz. One of the most challenging aspects of a retrofit applica- tion is locating the existing End -of -Line (EOL) resistor. In these applications that have EOL values, other than the 3.9k normally used with the HPFF8, a single resistor matching the existing EOL can be used as a reference for all the outputs. This feature speeds the installation and the system checkout, because the actual EOL does not need to be located and changed in the circuit. The reference resistor must be within the range of 1.9k to 25k. NPFF8 NAC Expander/Power Supply HPFF8 Features • Four (4) supervised notification application circuits (NACs) capable of supplying +24VDC at 3.0 amp maximum each • NAC output circuits may be configured as any of the following: -Four Class B (Style Y) - Two Class B & one Class A - Two Class A (Style Z) - Four Class A with the optional HPP31076 Class adapter installed • Four field -programmable operational modes • 2.0 amp auxiliary continuously supplied output • Two (2) fully supervised input/output control circuits • Temporal coding and sync protocols compatible with the following notification appliance brands: - System Sensor - Faraday - Gamewell - Amseco - Cooper -Wheelock - Gentex • Supervised AC input, battery voltage, auxiliary output, charger, and earth ground faults • Trouble indication for supervision of the following: - NAC circuits - Auxiliary output - AC input - Charger - Battery voltage - Open contacts in the initiat- - Earth ground faults by ing device signal inputs (for individual status LED's FACP trouble notification) • Separate Trouble and AC Fail Form -C relay Contacts An ISO 9001-2000 Company OU� LISTED 558E562 O 524 7. 02 GAMEWELL-FC] 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 SpecMcations are for information only, are not intended for installation purposes, and are subjec"o change without notice. No responsibility is assumed by Gamemll4Cl kr Meir use. �020fOby Honeywell lntematbnalinc. Alidghts reserved. WWW. gameweli,fcl.com 9021-60521 Rev. B page 1 of 2J Nelson I d I L I I Systems FIRE CONTROL INSTRUMENTS-GAMEWELL-BOSCH 1481 SOUTH MAJOR STREET S.L.C., UT 84115 P. 801-468-8300 F. 801-468-8305 www.nelsonfire.com BYU - Idaho Science and Technology Building Fire Alarm System Battery Calcs & Voltage Drop $Garnemli System Current Draw- Main Panel E3 Series Control Panel with Broadband Device I Qty Total Standby ndby Current Draw 0.650 A Standby O Total Alarm Alarm Current Draw I 35.505 A Alarm 1. System Device Intel. Loop Interface, Main Board ILI-MB-E3 1 x 1 0.08100 0.08100 1 x 0.15000 0.15000 Intel. Loop Interface Supplement Board ILI-S-E3 1 x 0.08100 0.08100 1 x 0.15000 0.15000 Intel. Loop Interface Main Board - A olio ILI95-MB-E3 0 x 0.05000 0 x 0.09100 Intel. Loop Interface Supplement Board - Apollo ILI95-S-E3 0 x 0.05000 0 x 0.09100 7100 Panel, 1 SLC 0 x 0.05600 0 x 0.07600 7100 Panel, 1 SLC with DACT 0 x 0.07500 0 x 0.09500 7100 Panel, 2 SLC 0 x 0.06500 0 x 0.08500 7100 Panel 2 SIC with DACT 0 x 0.08500 0 x 0.10500 2. E3 Optional Modules 120V Pourer Supply Sub -Assembly PM -9 1 x 0.05000 0.05000 1 x 0.05000 0.05000 240V Power Supply Sub -Assembly PW9G) 0 x 0.02700 0 x 0.05000 LCD Display & Switch Control LCD -E3 3 x 0.02400 0.07200 3 x 0.02800 0.08400 ARCNET Repeater RPT -E3 0 x 0.01300 0 x 0.01300 Digital Communicator DACT-E3 0 x 0.01800 0 x 0.01800 Optional Remote Serial Annunicator LCD -7100 0 x 0.05000 0 x 0.07500 Network LCD Annunicator (NGA) 0 x 0.20000 0 x 0.20000 Auxiliary Switch Sub -Assembly ASM -16 3 x 0.01100 0.03300 3 x 0.01100 0.03300 Remote LED Driver Module ANU-48 0 x 0.01100 0 x 0.01100 Addressable Node Ex ander ANX 0 z 0.06500 0 x 0.06500 3. 7100 Optional Modules Intelligent Network Inferface Module INI-7100 0 z 0.04000 0 x 0.04000 Printer Transient Module PTRM 0 x 0.02000 0 1 x 1 0.02000 Remote LED Driver Module LDM-7100) 0 1 x 1 0.03500 0 1 x 1 0.20000 0 Class A tion Module CAOM 0 z 0.00100 0 x 0.00100 UOIG a Ifc" ,Un ua X I V.UVIVv I 1 0 1 X �ommana van er Intel. Network Command CenterINI-VGC 0 x 0.15000 0 x 0.15000 Addressable Switch Sub-assemblyASM-16 0 x 0.01100 1 1 0 1 z 1 0.01100 Voice Paging Microphone Micro hone 0 I x I 0.00100 I I 0 I x I 0.00100 Firefighter's Telephone Handset 0 1 x 1 0.02000 1 1 0 1 z 1 0.02000 5. INI-VGX Voice Gateway Intel. Network Voice Gateway INI-VGX 0 x 1 0.15000 0 x 0.15000 120V Power Supply Sub -Assembly PM -9 0 0 z 0.05000 240V Power Su Sub-AssemblyPM-9G 0 0 x 0.05000 Amplifier Sub-assembly,50 watt 25V AM -50 0 0 z 2.20600 Amplifier Sub-assembly,50 watt 70V AM -50-70 0 LO.O4900 0 x 2.30000 Addressable Output Module -Signal AOM-2SF 0 0 x 0.00650 Addressable Out ut Module -Tele hone AOM -TEL 0 0 x 0.00650 Addressable Out ut Module -Audio AOM -MUX 0 0 x 0.00650 6. INI-VGE Command Center Voice Gateway Intel. Network Command Voice Gateway (IN] -VGE) 1 x 0.15000 0.15000 1 x 0.15000 0.15000 Addressable Switch Sub -assembly ASM -16 0 x 0.01100 0 x 0.01100 Voice Paging Microphone (Microphone) 3 x 0.00100 1 0.00300 3 x 0.00100 0.00300 AA Series Audio Amplifier AA -120 3 x 0.05100 0.15300 3 x 7.30000 21.90000 Addressable Output Module -Signal AOM-2SF 0 x 0.00200 0 x 0.00650 Addressable Output Module -Telephone AOM -TEL 0 x 0.00200 0 x 0.00650 Addressable Output Module -Audio AOM -MUX 0 x 0.00200 0 x 0.00650 7. Smoke Detectors/Modules ASD-PL2F 13 x 0.00030 0.00390 13 x 0.00650 0.08450 ATD-RL2F 5 x 0.00030 0.001505 x 0.00650 0.03250 DNR 48 x 0.00030 0.01440 48 x 0.00650 0.31200 AMM4F 7 x 0.00038 0.00263 7 x 0.00500 0.03500 AOM-2RF 12 x 0.00038 0.00450 12 x 0.00650 0.07800 MS-7AF 1 x 0.00030 0.00030 1 x 0.00300 0.00300 CO1224T 0 x 0.02000 0 x 0.04000 8. Notification Appliances SPSCW 223 x 0.00000 0.00000 223 1 x 0.04000 8.92000 SPCW 88 x 0.00000 0.00000 88x 0.04000 3.52000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 Total Standby Load: 0.650 A Total Alarm Load: 35.505 A 0 � System Power Requirements a E3 Fire Alarm Control Panel with Broadband Protected Premises: BYU-Idaho Science and Technology Building Date: 1/12/2015 Address: City: Rexburg State: ID Zip: Prepared ENelson Fire Systems Phone: 801-4( Address: 1481 S Major Street Email: officeno nelsonfre.cc City: Salt Lake City State: Utah Zip: 84115 Secondary Load Requirements 35.51 Amp Hours TMl Ccn.. A.m, I naa from the ralru afinn fahle holnw Battery Selection 55.00 Amp Hours Select batteries from the list 55 AH Battery 12 volt) Battery Distribution Chart Shows amp -hour distribution of your selections. _ Mpare Bali¢ry CaPmOy esacandary slawby Load @SeeoMaq Alarm Load Secondary Standby Load 1 34% ISPare Battery Ca aci 25.62 Amp Hours Secunda Standb Load 18.73 Amp Hours Secunda Alarm Load 10.65 Amp Hours Secondary Standby Load Required Standb Time 0.650 A x 24 hours 15.61 Secondary Alarm Load Required Alarm Time (hours) 35.505 A x 0.250 hours 8.88 Total Secondary Load 24.48 Derating factor x 1.20 Secondary Load Requirements 29.38 AH Battery Selection 55.00 Amp Hours Select batteries from the list 55 AH Battery 12 volt) Battery Distribution Chart Shows amp -hour distribution of your selections. _ Mpare Bali¢ry CaPmOy esacandary slawby Load @SeeoMaq Alarm Load Secondary Standby Load 1 34% ISPare Battery Ca aci 25.62 Amp Hours Secunda Standb Load 18.73 Amp Hours Secunda Alarm Load 10.65 Amp Hours Honeywell System Current Draw - HPFF8 #7 Standb 0.075 A Alarm 1.024 A 1. S stem Modules HPFFS Main Circuit Board 1 x 1 0.07500 0.07500 1 x 0.20600 0.20600 2. L-25 BPSCW16 10 x 1 0.00000 0.00000 10 0.06600 0.66000 SPSCW75 1 x 0.00000 0.00000 1 _2L x 0.15800 0.15800 o 000 0 x 0.00000 0 0 x 0.00000 o 0 x 0.00000 o 9X0.0000E000 o x 0.00000 0 0 x 0.00000 o o x 0.00000 NAC #1 Totals Max 3 Amps):. 0.00000 0.81800 3 0 1 x 1 0.00000 0 z 0.00000 0 x 1 0.00000 3 x 0.00000 0.00000 o x 0.00000 o x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0,00000 0 x 0.00000 0 x 000000 0 x 0.00000 0 x 0.00000 0 x 0.00000 o x 0.00000 NAC #2 Totals Max 3 Am s : 0.00000 0.00000 4 0 z I 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 0 x 0.00000 0 0 x 0.00000 0 0 x 0.00000 0 N000000 0 x 0.00000 0 0 x 0.00000 0 0 x 0.00000 NAC 03 Totals Max 3 Am s : 0.00000 0.00000 5 o 1 x 1 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 o x 0.00000 o x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x ..00000 0 x 0.00000 NAC #4 Totals Max 3 Amps): 0.00000 0.00000 6. Auxiliary Power Auxiliary Device 0 0 x 0.00000 Auxilia Device 00 0 x 0.00000 Auxilia Device 00 0 x 0.00000 Auxilia Device 00 =Amps) 0 x 0.00000 AuxiliaryDevice 00 0 x 0.00000 m s : 0.00000 0.00000 7. Compatible Devices not Ilsted Other compatible devices 20.00000 0 x 0.00000 Other compatible devices 0 x1 0.00000 0 x 0.00000 Other compatible device s 0 x 1 0.00000 0 x 0.00000 Total Non-Alarm Load: 0.075 1 Total Alarm Load: 1.024 Secondary Power Requirements Protected Premises: BYU-Idaho Science and Technology Bldg Date: 1/12/2015 Address: City: Rexburg State: ID Zip: Prepared By: Nelson Fire Systems Phone: 801.468.8300 Address: 1481 S Maior Street Email: ofilcena nelsonfrexom City: Salt Lake City State: UT Zip: 84115 Secondary Load Requirements 2A7 Amp Hours Total Secondary Load from the calculation table below. Current Draw Secondary Standby Load 0.075 A x Time (hours) Re uired Standby Time Total (AH) 24 hours 1.80 Secondary Alarm LoadRe 1.024 A x uired Alarm Time hours 0.250 hours 0.26 Total Secondary Load 2.06 Derating factorl x 1.2 Secondary Load Requirements 1 2.47 Battery Selection ® Amp Hours Select batteries from the list below. 8.0 AH BAT -1270 Battery 12 volt Battery Distribution Chart Shows amp-hour distribution of your selections. Secondary Alarm Load 4% ■ Spare Battery Capacity Secondary Standby Load III Secondary Standby Load 27% ■Secondary Alarm Load 0 Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (8AH) are within the charger range of this power supply (7-26AH). S are Battery Capacity 5.53!Battery Selection AH -secondary Load Requirements AH ISeconclary Standby Load 2.16 ISeconclary, Standby Load AH * Deratinci Factor ISeconclary Alarm Load 1 0.31 ISeconclary Alarm Load AH ' Derailing Factor Page 3 of 129 Honeywell System Current Draw - HPFF8 #2 --.. 5[andb 0.075 A Alarm 2.572 A De 1. System Modules a r 01, Ore. HPFF8 Main Circiit Board 1 1 x 1 0.07500 1 007500 1 z 1 0.20600 0.20600 2. L-5 SPSCW15 1 x 0.00000 0.00000 1 x 0.06600 0.06600 SPSCW30 7 x 0.00000 0.00000 7 x 0.09400 0.65800 0 x 0.00000 0 z 0.00000 00.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 z 0.00000 0 x 0.00000 0 x 0.00000 a x 0.00000 NAC41 T :1 0.00000 0.72400 3. L6 SPSCWI5 3 z 1 0.00000 0.00000 3 x 0.06600 0.19800 SPSCW30 4 x 0.00000 0.00000 3 x 0.09400 0.28200 0 x 1 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 o x 0.00000 0 x 0.00000 NAC #2 Total(Max3AMPs):l 0.00000 1 0.48000 4. L-7 SPSCWI5 5 x 0.00000 0.00000 5 z 0.06600 0.33000 SPSCW30 4 x 0.00000 0.00000 4 z 0.09400 0.37600 0 x 0.110000 0 x 0.00000 00.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #3 Totals Max 3 Am s : 0.00000 0.70600 5. Loi 0 x 0.00000 o -2L 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 SPSCW15 6 x 0.00000 0.00000 6 x 0.06600 0.39600 SPSW30 0 x 0.00000 0 x 0.09400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 z 0.00000 NAC #4 Totals Max 3 Ams : 0.00000 0.39600 6. Auxillary Pourer Auxiliary Device 1 0 1XI 0.00000 0 x 0.00000 Auxiliary Device0 z 0.00000 0 x 0.00000 AuxiliaryDevice 0 x 0.00000 0 z 0.00000 Auyjllaq Device 1 0 1XI 0.00000 0 x 0.00000 Auxilia Device 0 x 0.00000 0 x 0.00000 TB4 Totals Max 2 Amps). 0.00000 0.00000 7. Com alible Devices not listed Other compatible devices 0 x 0.00000 0 z 0.00000 Other com atible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 1 0 1XI 0.00000 1 1 0 x 1 0.00000 Total Non -Alarm Load: 0.075 Total Alarm Load: 2.512 Honeyweii Secondary Power Requirements Protected Premises: BYU-Idaho Science and Technology Bldg Address: City: Rexburg State: ID Prepared By: Nelson Fire Systems Address: 1481 S Major Street Email: City: Salt Lake City State: UT Secondary Load Requirements 2.91 Amp Hours Total Secondary Load from the calculation table below. Date Zip: Phone: nelson Zip: Current Draw Secondary Standby LoadRe 0.075 A x I Time (hours) Total (AH) uired Standby Time 24 hours 1.80 Secondary Alarm Load 2.512 A x Re uired Alarm Time hours 0.250 hours 0.63 Total Secondary Load 2.43 Derating factor x 1.2 Secondary Load Requirements 2.91 Battery Selection ® Amp Hours Select batteries from the list below. 8.0 AH BAT -1270 Battery 12 volt Battery Distribution Chart Shows amp -hour distribution of your selections. Secondary Alarm Load 9% Secondary Standby Load 27% ■ Spare Battery Capacity ■ Secondary Standby load •Secondary Alarm Load j I F -- Comments 1. Batteries will ft in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (8AH) are within the charger range of this power supply (7-26AH). Page 3 of 129 "oneywoll System Current Draw - HPFF8 #3 -:£�Alarm4.582 s . . 1. System Modules HPFF8 Main Circuit Board 1 x 0.07500 1 0.07500 7 1 x 0.20600 0.20600 2. L-9 SPSCW15 4 x 0.00000 0.00000 4 x 0.06600 0.26400 SPSCW30 1 x 0.00000 0.00000 1 z 0.09400 0.09400 SPSCW75 5 x90.000000,0 0.00000 5 x 0.15800 0.79000 0 x 0 x 0.00000 0 x 0 x 0.00000 0 x 0 x 0.00000 o x 0 x 0.00000 o x 0 x 0.00000 NAG 91 Totals Max 3 Amps):j 0.00000 1.74800 3. L-18 SPSCW15 9 x 0.00000 0.00000 9 x 0.06600 0.59400 SPSCW75 1 x 0.00000 0.00000 3 x 0.15800 0.47400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 z 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #2 Totals Max 3 Amps):. 0.00000 1.06800 4. L-11 SPSCW75 1 x 1 0.00000 0.00000 1 x 0.06600 0.06600 SPSCW75 7 x 0.00000 0.00000 7 x 0.15800 1.10600 0 0 x 0.00000 0 0 x 0.00000 0 0 x o.00000 0 MOOOOOD 0 x 0.00000 0 0 x 0.00000 0 0 x 0.00000 NAC #3 To1al5 Max 3Am s : 0.00000 1.17200 5.L-12 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 SPSCW75 3 x 0.00000 0.00000 3 x 0.06600 0.19800 SPSW75 5 x 0.00000 0.00000 5 x 0.15800 0.79000 0 x 0.00000 0 x 000000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #4 Totals Max 3 Amps),0.00000 0.98800 6. Auxiliary Pourer Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxillant Device 0 x 1 0.00000 0 x 0.00000 Auxiliary Device 0 z 0.00000 0 x 0.00000 T84 Totals Max 2 Amps): 0.00000 0.00000 7. Compatible Devices not listed Other compatible devices 0 x 0.00000 0 z 0.00000 Other compatible devices 0 x 0.00000 0 1 x 1 0.00000 Other compatible devices 0 x 0.00000 0 1 x 1 0.00000 Total Non -Alarm Load: 0.075 Total Alarm Load: 1 4.582 Secondary Power Requirements Protected Premises: BYU-Idaho Science and Technology Bldg Date: Address: City: Rexburg State: ID Zip: Prepared By: Nelson Fire Systems Phone: Address: 1481 S Ma or Street Email: Miceftneison City: Salt Lake City State: UT Zip: Secondary Load Requirements 3.53 Amp Hours Total Secondary Load from the calculation table below. Current Draw Secondary Standby Load 0.075 A Time (hours) Re uired Standb Time Total (AH) x 24 hours 1.80 Secondary Alarm Load 4.582 A x Re uired Alarm Time hours 0.250 hours 1.15 Total Secondary Load 2.95 Derating factorl x 1.2 Secondary Load Requirements 1 3.53 Battery Selection ® Amp Hours Select batteries from the list below. 8.0 AH BAT -1270 Battery 12 volt Battery Distribution Chart Shows amp-hour distribution of your selections. Secondary Alarm Load 17% ■ Spare Batterycapacity ■ Secondary Standby lead ■Secondary Alarm Load 119 Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (8AH) are within the charger range of this power supply (7-26AH). S are Battery Capacity 4.47 Batter Selection AH - Secondary Load Requirements AH Secondary Standby Load 1 2.16 Secondary Standby Load AH ' Derating Factor ISecondary Alarm Load 1 1.37 1 Secondary Alarm Load AH ' Derating Factor Page 3 of 129 Honeywell System Current Draw - HPFF8 #4 Sta ndb 0.075 A a Alarm 3.900 A .. 1. 8 stem Modules SicoVan� �on-AWT =,t.,," Secondary - Alarm Current HPFF8 Main Circuli Board 1 x 0.07500 1 0.07500 1 x I 0.20600 0.20800 2. L-13 SPSCW15 12 x 0.00000 000000 12 x 0.06600 0.79200 SPSCW75 2 x 0.00000 0.00000 2 x 0.15800 0.31600 0 0.00000 0 x 0.00000 0 0.00000 0 x 0.00000 0 0.00000 0 x 0.00000 0 ix 0.00000 0 x 0.00000 0 0.00000 0 x 0.00000 o o.oa000 o x 0.00000 NAC #1 Totals Max 3 Amps): 0.00000 1.10800 3. L-14 SPSCW15 3 x 0.00000 0.00000 3 x 0.06600 0.19800 SPSCW75 6 x 0.00000 0.00000 3 x 0.15800 0.47400 0 000 0 x 0.00000 0 000 0 x 0.00000 o 000 0 x 0.00000 o 000 LXO. 0 z 0.00000 0 000 0 x 0.00000 o 000 a x 0.00000 NAC #2 Totals Max 3 Amps): 0.00000 0.67200 4. L45 SPSCW15 1 x 0.00000 0.00000 1 x 0.06600 0.06600 SPSCW30 2 x 0.00000 0.00000 2 x 0.09400 0.18800 SPSCW75 4 x 0.00000 0.00000 4 x 0.15800 0.63200 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #3 Totals Max 3 Amps):il 0.00000 1 0.88600 5. L-16 0 x 0.00000 0 x 0.00000 0 x 0.00000 o x 0.00000 o x 0.00000 o x 0.00000 SPSCW15 6 x 0.00000 0.00000 6 z 0.06600 0.39600 SPSW75 4 x 0.00000 0.00000 4 z 0.15800 0.83200 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #4 Totals Max 3 Am s : 0.00000 1.02800 S. Auxiliary Power Auxiliary Device 0 x 0.00000 0 x 0.00000 AuxiliaN Device 0 x 0.00000 0 x 0.00000 A.xiliar, Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 z 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 TB4 Totals Max 2 Amps).. 0.00000 0.00000 7. Compatible Devices not listed Other com atible devices 0 x 0.00000 0 x 0.00000 Other oom atible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 1 x 1 0.00000 0 1 x 1 .00000 Total Non -Alarm Load: 0.075 Total Alarm Load: 3.900 Secondary Power Requirements HPFF8 Power Protected Premises: BYU-Idaho Science and Technology Bldq Date: Address: City: Rexburg State: ID Zip: Prepared By: Nelson Fire Systems Phone: Address: 1481 S Ma or Street Email: orriceanneison City: Salt Lake City State: UT Zip: Secondary Load Requirements 3.33 Amp Hours Total Secondary Load from the calculation table below. Current Draw Secondary Standby Load 0.075 A Re uired Standb Time x 24 hours 1.80 Secondary Alarm Load 3.900 A Re uired Alarm Time hours x 0.250 hours 0.98 Totaleconda Load 2.78 Derating factorl x 1.2 Secondary Load Requirements 1 3.33 Battery Selection ® Amp Hours Select batteries from the list below. 8.0 AH BAT -1270 Battery 12 volt Battery Distribution Chart Shows amp -hour distribution of your selections. SecondaryAlarm Load IM Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (8AH) are within the charger range of this power supply (7-26AH). Page .+ of 129 Honeywell Standby 0.076 A 'Alarm 12.864A .. . System Current Draw - HPFF8 #5 rQtyr . 1. System Modules HPFF8 Main Circuit Board I 1 1XI 0.07500 0.07500 I 1 x 1 0.20600 0.20800 2. L-17 SPSCW15 8 x 0.00000 1 0.00000 8 x 0.06600 0.52800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 o x 0.00000 0. x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #1 Totals Max 3 Am s: 0.00000 0.52800 3. L-18 SPSCW15 5 x 0.00000 1 0.00000 5 x 0.06600 0.33000 SPSCW30 1 x 0.00000 0.00000 3 x 0.09400 0.28200 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC q2 Totats Max 3 Am s : 0.00000 0.61200 4. L-19 SPSCWI5 8 x 0.00000 0.00000 8 x 0.06600 0.52800 SPSCW30 1 x 0.00000 0.00000 1 x 0.09400 0.09400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 o x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #3 Totals Max 3 Amps): 0.00000 0.62200 5.L-20 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 SPSCWI5 4 x 0.00000 0.00000 4 x 0.06600 0.26400 SPSW76 4 x 0.00000 0.00000 4 x 0.15800 0.63200 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #4 Totals Max 3 Amps): 0.00000 0.89600 6. Auxilia Pourer Auxiliary Device 0 x 0.00000 0 x 0.00000 AuxiliaryDevice 0 x 0.00000 0 x 0.00000 Auxilia Device 0 x 0.00000 0 x 0.00000 AuxiliaryDevice 0 x 0.00000 0 x 0.00000 AuxiliaryDevice 0 x 0.00000 0 x 0.00000 T64 T)lots Max 2Amps) '. 0.00000 000000 7. Compatible Devices not listed Other compatible devices 0 x 0.00000 0 x 0.00000 Other oom atible devices 0 x 0.00000 0 x 0.00000 Olhef opm alible tleVices 0 1 x 1 000000 10 x 0.00000 Total Non -Alarm Load: 0.075 Total Alarm Load: 2.864 Secondary Power Requirements Protected Premises: BYU-Idaho Science and Technology Bldg Date: Address: City: Rexburg State: ID Zip: Prepared By: Nelson Fire Systems Phone: Address: 1481 S Major Street Email: off-, C-Pnelsor City: Salt Lake City State: UT Zip: Secondary Load Requirements F 3.02 Amp Hours Total Secondary Load from the calculation table below. Current Draw Secondary Standby Load 0.075 A x Time (hours) Total (AH) Re uired Standb Time 24 hours 1.80 Secondary Alarm LoadRe 2.864 A x uired Alarm Time hours 0.250 hours 0.72 Total Secondary Loadl 2.52 Derating factorl x 1.2 Secondary Load Requirements 1 3.02 Battery Selection ® Amp Hours Select batteries from the list below. 8.0 AH BAT -1270 Battery 12 volt Battery Distribution Chart Shows amp-hour distribution of your selections. Secondary Alarm Load 11% ■ Spare Battery Capacity ■ Secondary Standby Load ■SecondaryAlarm Load Secondary Standby Load 27% 40 Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (8AH) are within the charger range of this power supply (7-26AH). 4.98 S Batte Selection AH - Seconds Load Requirements AH geare undb Load I 2.16 ISecondary Standby Load AH . Derating Factor Seconds Alarm Load 1 0.86 ISecondary Alarm Load AH * Derating Factor Page 3 of 129 Honeywell System Current Draw - HPFF-8 #6 Slandb 0.075 A -`Alarm 3.630 A 1. 5 stem Modules HPFFB Main Circuit Board 1 1 x 1 0.07500 0.07500 1 x 0.20600 0.20600 2.1--21 SPSCW15 5 x 0.00000 0.00000 5 x 0.06600 0.33000 SPSCW75 4 x 0.00000 0.00000 4 x 0.15800 0.63200 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 z- 0.00000 0 x 0.00000 0 x D.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #1 Totals Max 3 Am s : 0.00000 0.96200 3. L-22 SPSCW15 4 x 0.00000 0.00000 4 z 0.06600 0.26400 SPSCW75 4 x 0.00000 0.00000 3 x 0.15800 0.47400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 X 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 X 0.00000 NAC #2 Totals Max 3 Am s : 0.00000 0.73800 4. L-23 SPSCW15 2 x 1 0.00000 1 0.00000 2 x 0.06600 0.13200 SPSOW30 2 X 0.00000 1 0.00000 2 X 0.09400 0.18800 SPSCW75 4 x 0.00000 0.00000 4 x 0.15800 0.63200 0 x 0.00000 o x 0.00000 0 x 0.00000 0 x 0.00000 0 X 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 D x 0.00000 NAC #3 Totals Max 3 AMPS): 0.00000 1 0.95200 5. L-24 0 z 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 SPSCW15 6 x 0.00000 0.00000 6 X 0.06600 0.39600 SPSW30 4 x 0.00000 0.00000 4 X 0.09400 0.37600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 X 0.00000 0 x 0.00000 NAC #4 Totals Max 3 Am s : 0.00000 0.77200 6. Auxllle Power Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxifiaty Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 X 0.00000 Auxiliary Device 0x 0.00000 0 x 0.00000 AuxiliaryDevice 0 z 0.00000 0 x 0.00000 TB4 Totals Max 2 Am s : 0.00000 0.00000 7. Compactible Devices not listed Other compatible devices0 x 0.00000 0 z 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Other Compatible devices 0 x 0.00000 0 x 0.00000 Total Non -Alarm Load: 0.075 Total Alarm Load: 3.830 Secondary Power Requirements HPFF8 Power Supply 1 Protected Premises: BYU-Idaho Science and Technology Bldg Date: Address: City: Rexburg State: ID Zip: Prepared By: Nelson Fire Systems Phone: Address: 1481 S Maior Street Email: office@nelsor City: Salt Lake City State: UT Zip: Secondary Load Requirements F 3.25 Amp Hours Total Secondary Load from the calculation table below. Current Draw Secondary Standby Load 0.075 A x Time (hours) Total (AH) Re uired Standby Time 24 hours 1.80 Secondary Alarm Load 3.630 A x Re uired Alarm Time hours 0.250 hours 0.91 Total Secondary Load 2.71 Derating factorl x 1.2 Secondary Load Requirements 1 3.25 Battery Selection ® Amp Hours Select batteries from the list below. 8.0 AH 13AT-1270 Battery 12 volt Battery Distribution Chart Shows amp -hour distribution of your selections. Secondary Alarm Load IAM Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (8AH) are within the charger range of this power supply (7-26AH). Page 3 of 129 Job Name: Science and Technology B... BYU -Idaho Rexburg, 10 AHI: BYU - Idaho Circuit Information Panel Name: FF8 1 Circuit Name: L-1 Starting Voltage: Starting Voltage = 20.4 Prepared By: Alex Kinney ELE-SI-27613 Nelson Fire Systems 1481 South Major Street Salt Lake City, 84115 801-468-8300 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and volume Dist from Dist from 12 14 16 18 (Amps) last device source (ft) Speaker/Strobe 75 0.158 100 100 19.987 19.744 19.356 18.739 SPSCW Speaker/Strobe 75 0.158 20 120 19.917 19.633 19.179 18.458 SPSCW Speaker/Strobe 15 0.066 20 140 19.860 19.542 19.034 18.227 SPSCW Speaker/Strobe 15 0.066 20 160 19.808 19.460 18.903 18.019 SPSCW Speaker/Strobe 75 0.158 45 205 19.703 19.293 18.638 17.597 SPSCW Speaker/Strobe 75 0.158 35 240 19.643 19.199 18.488 17.358 SPSCW Speaker/Strobe 15 0.066 40 280 19.601 19.132 18.380 17.188 SPSCW Speaker/Strobe 15 0.066 35 315 19.573 19.088 18.310 17.076 SPSCW Speaker/Strobe 15 0.066 20 335 19.562 19.071 18.283 17.033 SPSCW Speaker/Strobe 15 0.066 20 355 19.557 19.062 18.270 17.012 SPSCW Total current/amps 1.028 Total Dist:355 voltage drop 0.843 1.338 2.130 3.388 1/13/2015 1 �� SYSTEM 40 SENSOR` advanced ideasadvanced soluliom. Circuit Information Panel Name: FF8 1 Circuit Name: L-2 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 16 (Amps) last device source (ft) Speaker/Strobe 15 0.066 150 150 19.833 19.500 18.967 18.121 SPSCW Speaker/Strobe 15 0.066 30 180 19.728 19.333 18.701 17.698 SPSCW Speaker/Strobe 15 0.066 20 200 19.663 19.230 18.537 17.437 SPSCW Speaker/Strobe 30 0.094 20 220 19.603 19.135 18.386 17.197 SPSCW Speaker/Strobe 15 0.066 20 240 19.551 19.053 18.254 16.987 SPSCW Speaker/Strobe 15 0.066 20 260 19.504 18.978 18.136 16.799 SPSCW Speaker/Strobe 15 0.066 20 280 19.463 18.913 18.031 16.632 SPSCW Speaker/Strobe 15 0.066 30 310 19.409 18.826 17.894 16.414 SPSCW Speaker/Strobe 15 0.066 30 340 19.362 18.753 17.777 16.228 SPSCW Speaker/Strobe 30 0.094 20 360 19.337 18.712 17.712 16.125 SPSCW Speaker/Strobe 15 0.066 20 380 19.319 18.684 17.667 16.053 SPSCW Speaker/Strobe 75 0.158 30 410 19.300 16.654 17.619 SPSCW Total current/amps 0.940 Total Dist:410 voltage drop 1.100 1.746 2.781 1/13/2015 Circuit Information Panel Name: FF8 1 Circuit Name: L-3 (1.5) amp circuit Class B @ 14 AWG Starting Voltage: Starting Voltage = 20.4 DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 18 (Amps) 0.158 last device source (ft) Speaker/Strobe 75 20 20 20.328 20.285 20.218 20.110 SPSCW Speaker/Strobe 15 0.066 - 30 50 20.239 20.144 19.992 19.751 SPSCW Speaker/Strobe 15 0.066 20 70 20.184 20.058 19.855 19.533 SPSCW Speaker/Strobe 75 0.158 20 90 20.135 19.980 19.731 19.337 SPSCW Speaker/Strobe 75 0.158 40 130 20.063 19.865 19.549 19.046 SPSCW Speaker/Strobe 15 0.066 75 205 19.975 19.726 19.326 18.692 SPSCW Speaker/Strobe 30 0.094 20 225 19.957 19.697 19.280 18.619 SPSCW Speaker/Strobe 15 0.066 20 245 19.946 19.680 19.253 18.576 SPSCW Speaker/Strobe 15 0.066 30 275 19.938 19.667 19.233 18.544 SPSCW Total current/amps 0.898 Total Dist:275 voltage drop 0.462 0.733 1.167 1.856 1/13/2015 emEm SOR' Circuit Information Panel Name: FF8 1 Circuit Name: L-4 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class 8 @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 i6 (Amps) last device source (ft) Speaker/Strobe 15 0.066 30 30 20.330 20.288 20.222 20.117 SPSCW Speaker/Strobe 30 0.094 20 50 20.288 20.222 20.117 19.949 SPSCW Speaker/Strobe 30 0.094 20 70 20.254 20.168 20.031 19.812 SPSCW Speaker/Strobe 15 0.066 30 100 20.214 20.105 19.930 19.652 SPSCW Speaker/Strobe 15 0.066 20 120 20.193 20.071 19.876 19.567 SPSCW Speaker/Strobe 15 0.066 20 140 20.177 20.046 19.836 19.503 SPSCW Speaker/Strobe 15 0.066 25 165 20.164 20.025 19.803 19.450 SPSCW Speaker/Strobe IS 0.066 20 185 20.158 20.016 19.789 19.428 SPSCW Total current/amps 0.584 Total Dist: 185 voltage drop 0.242 0.364 0.611 0.972 1/13/2015 Circuit Information Panel Name: FF8 2 Circuit Name: L-5 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 18 (Amps) last device source (R) Speaker/Strobe 15 0.066 110 110 20.038 19.826 19.486 18.946 SPSCW Speaker/Strobe 30 0.094 35 145 19.932 19.658 19.218 18.521 SPSCW Speaker/Strobe 30 0.094 25 170 19.866 19.553 19.051 18.255 SPSCW Speaker/Strobe 30 0.094 20 190 19.821 19.481 18.937 18.072 SPSCW Speaker/Strobe 30 0.094 25 215 19.774 19.406 18.817 17.883 SPSCW Speaker/Strobe 30 0.094 20 235 19.744 19.358 18.741 17.761 SPSCW Speaker/Strobe 30 0.094 30 265 19.710 19.304 18.655 17.624 SPSCW Speaker/Strobe 30 0.094 20 285 19.694 19.280 18.617 17.564 SPSCW Speaker/Strobe 30 0.094 30 315 19.683 19.262 18.588 17.518 SPSCW Total current/amps 0.818 Total Dist: 315 voltage drop 0.717 1.138 1.812 2.882 1/13/2015 5 Circuit Information Panel Name: FFS 2 Circuit Name: L-6 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 18 (Amps) last device source (ft) Speaker/Strobe 30 0.094 110 110 20.146 19.997 19.758 19.380 SPSCW Speaker/Strobe 30 0.094 20 130 20.108 19.936 19.661 19.225 SPSCW Speaker/Strobe 15 0.066 20 150 20.077 19.887 19.583 19.100 SPSCW Speaker/Strobe 15 0.066 20 170 20.051 19.846 19.518 18.996 SPSCW Speaker/Strobe 15 0.066 20 190 20.030 19.813 19.466 18.914 SPSCW Speaker/Strobe 30 0.094 20 210 20.015 19.789 19.428 18.853 SPSCW Speaker/Strobe 30 0.094 20 230 20.0011 19.717 19.409 18.823 SPSCW Total current/amps 0.574 Total Dlst:230 voltage drop 0.392 0.623 0.991 1.577 1/13/2015 Circuit Information Panel Name: FF8 2 Circuit Name: L-7 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit i Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 18 (Amps) last device source (ft) Speaker/Strobe 30 0.094 150 150 19.974 19.724 19.324 18.689 SPSCW Speaker/Strobe 30 0.094 30 180 19.900 19.607 19.138 18.392 SPSCW Speaker/Strobe 30 0.094 20 200 19.859 19.541 19.032 18.225 SPSCW Speaker/Strobe 30 0.094 30 230 19.808 19.460 18.903 18.019 SPSCW Speaker/Strobe 15 0.066 25 255 19.775 19.407 18.819 17.886 SPSCW Speaker/Strobe 15 0.066 50 305 19.721 19.323 18.685 17.672 SPSCW Speaker/Strobe 15 0.066 20 325 19.706 19.298 18.645 17.608 SPSCW Speaker/Strobe 15 0.066 20 345 19.695 19.281 18.618 17.566 SPSCW Speaker/Strobe 15 0.066 20 365 19.690 19.273 18.605 17.544 SPSCW Total current/amps 0.706 Total DIst:365 voltage drop 0.710 1.127 1.795 2.856 1/13/2015 7 Circuit Information Panel Name: FF8 2 Circuit Name: L-8 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 18 (Amps) last device source (ft) Speaker/Strobe 15 0.066 210 210 20.066 19.869 19.555 19.056 SPSCW Speaker/Strobe 15 0.066 20 230 20.039 19.827 19.488 18.949 SPSCW Speaker/Strobe 15 0.066 20 250 20.018 19.794 19.434 18.864 SPSCW Speaker/Strobe 15 0.066 20 270 20.002 19.768 19.394 18.800 SPSCW Speaker/Strobe 15 0.066 20 290 19.991 19.752 19.367 18.757 SPSCW Speaker/Strobe SS 0.066 20 310 19.986 19.743 19.354 18.736 SPSCW Total current/amps 0.396 Total Dist: 310 voltage drop 0.414 0.657 1.046 1.664 1/13/2015 Circuit Information Panel Name: FF8 3 Circuit Name: L-9 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 is (Amps) last device source (ft) Speaker/Strobe 15 0.066 100 100 19.939 19.668 19.234 18.545 SPSCW Speaker/Strobe 15 0.066 25 125 19.830 19.495 18.959 18.108 SPSCW Speaker/Strobe 75 0.158 20 145 19.748 19.365 18.752 17.779 SPSCW Speaker/Strobe 75 0.158 50 195 19.576 19.092 18.316 17.086 SPSCW Speaker/Strobe 75 0.158 20 215 19.519 19.002 18.174 16.860 SPSCW Speaker/Strobe 75 0.158 20 235 19.476 18.933 18.064 16.685 SPSCW Speaker/Strobe 75 0.156 20 255 19.445 18.884 17.986 16.561 SPSCW Speaker/Strobe 15 0.066 20 275 19.427 18.855 17.940 16.488 SPSCW Speaker/Strobe 15 0.066 20 295 19.414 18.835 17.908 16.436 SPSCW Speaker/Strobe 30 0.094 20 315 19.406 18.823 17.889 16.405 SPSCW Total current/amps 1.148 Total Dist:315 voltage drop 0.994 1.577 2.511 3.995 1/13/2015 9 Circuit Information Panel Name: FF8 3 Circuit Name: L-10 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 is (Amps) last device source (R) Speaker/Strobe 15 0.066 60 60 20.219 20.112 19.942 19.671 SPSCW Speaker/Strobe 15 0.066 20 80 20.163 20.025 19.802 19.449 SPSCW Speaker/Strobe 15 0.066 30 110 20.089 19.906 19.613 19.149 SPSCW Speaker/Strobe 15 0.066 20 130 20.044 19.835 19.501 18.970 SPSCW Speaker/Strobe 15 0.066 20 150 20.005 19.773 19.401 18.812 SPSCW Speaker/Strobe 15 0.066 20 170 19.971 19.719 19.316 18.675 SPSCW Speaker/Strobe 15 0.066 20 190 19.942 19.674 19.243 18.560 SPSCW Speaker/Strobe 15 0.066 20 210 19.919 19.637 19.184 18.467 SPSCW Speaker/Strobe 15 0.066 20 230 19.901 19.608 19.139 18.394 SPSCW Speaker/Strobe 75 0.158 20 250 19.888 19.588 19.107 18.343 SPSCW Total current/amps 0.752 Total Dist:250 voltage drop 0.512 0.812 1.293 2.057 1/13/2015 10 Circuit Information Panel Name: FF8 3 Circuit Name: L-11 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 16 (Amps) last device source (ft) Speaker/Strobe 75 0.158 100 100 19.892 19.594 19.116 18.357 SPSCW Speaker/Strobe 75 0.158 25 125 19.781 19.417 18.835 17.911 SPSCW Speaker/Strobe 75 0.158 20 145 19.704 19.296 18.642 17.604 SPSCW Speaker/Strobe 75 0.158 25 170 19.625 19.170 18.442 17.285 SPSCW Speaker/Strobe 75 0.158 30 200M5372 18.249 16.979 SPSCW Speaker/Strobe 75 0.158 35 2353 18.080 16.711 SPSCW Speaker/Strobe 75 0.158 25 2603 18.000 16.583 SPSCW Speaker/Strobe 75 0.158 30 2903 17.952 16.506 SPSCW Total current/amps 1.264 Total Dist: 290 voltage drop7 2.448 3.894 1/13/2015 11 Circuit Information Panel Name: FF8 3 Circuit Name: L-12 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 16 (Amps) last device source(R) Speaker/Strobe 15 0.066 150 150 19.804 19.454 18.894 18.005 SPSCW Speaker/Strobe 75 0.158 20 170 19.730 19.337 18.707 17:707 SPSCW Speaker/Strobe 75 0.158 30 200 19.638 19.191 18.474 17.337 SPSCW Speaker/Strobe 15 0.066 35 235 19.553 19.055 18.259 16.994 SPSCW Speaker/Strobe 15 0.066 25 260 19.498 18.969 18.121 16.776 SPSCW Speaker/Strobe 75 0.158 25 285 19.451 18.894 18.001 16.584 SPSCW Speaker/Strobe 75 0.158 30 315 19.413 18.833 17.905 16.431 SPSCW Speaker/Strobe 75 0.158 25 340 19.397 18.808 17.86516.367 SPSCW Total current/amps 0.988 Total Dist: 340 voltage drop 1.003 1.592 2.535 4.033 1/13/2015 12 I Circuit Information Panel Name: FF8 4 Circuit Name: 1-13 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 18 (Amps) last device source (ft) Speaker/Strobe 15 0.066 120 120 19.866 19.552 19.049 18.251 SPSCW Speaker/Strobe 75 0.158 20 140 19.782 19.419 18.837 17.915 SPSCW Speaker/Strobe 15 0.066 20 160 19.711 19.306 18.658 17.629 SPSCW Speaker/Strobe 15 0.066 20 180 19.645 19.202 18.492 17.365 SPSCW Speaker/Strobe 15 0.066 20 200 19.584 19.106 18.339 17.121 SPSCW Speaker/Strobe 15 0.066 20 220 19.529 19.018 18.199 16.900 SPSCW Speaker/Strobe 15 0.066 20 240 19.479 18.939 18.073 16.699 SPSCW Speaker/Strobe 75 0.158 20 260 19.435 18.868 17.961 16.520 SPSCW Speaker/Strobe 15 0.066 20 280 19.403 18.818 17.880 16.392 SPSCW Speaker/Strobe 15 0.066 20 300 19.377 18.776 17.813 16.286 SPSCW Speaker/Strobe 15 0.066 20 320 19.355 18.742 17.760 16.200 SPSCW Speaker/Strobe 15 0.066 50 370 19.315 18.679 17.659 16.040 SPSCW Speaker/Strobe 15 0.066 20 390 19.305 18.662 17.632 SPSCW Speaker/Strobe 15 0.066 20 410 19.300 18.654 17.619 SPSCW Total current/amps 1.108 Total Dist:410 voltage drop 1.100 1.746 2.781 1/13/2015 13 Circuit Information Panel Name: FF8 4 Circuit Name: L-14 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 18 (Amps) last device source (R) Speaker/Strobe 75 0.158 250 250 19.248 18.572 17.489 SPSCW Speaker/Strobe 75 0.158 30 280 19.129 18.383 17.188 SPSCW Speaker/Strobe 75 0.158 30 310 19.029 18.224 16.935 SPSCW Speaker/Strobe 75 0.158 30 340 18.948 18.096 16.730 SPSCW Speaker/Strobe 75 0.158 30 370 18.886 17.997 16.574 SPSCW Speaker/Strobe 75 0.158 30 400 18.843 17.929 16.465 SPSCW Speaker/Strobe 15 0.066 30 430 18.819 17.891 16.405 SPSCW Speaker/Strobe 15 0.066 20 450 18.809 17.874 16.378 SPSCW Speaker/Strobe 15 0.066 20 470 18.803 17.866 16.364 SPSCW Total current/amps 1.146 Total DIst:470 voltage drop 1.597 2.534 4.036 1/13/2015 14 OF, SYSTEM D4O SENSOR` advanced dects. advanced 57iu1icys. Circuit Information Panel Name: FF84 Circuit Name: L-15 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 is (Amps) last device source (ft) ipeaker/Strobe 75 0.158 250 250 19.510 18.987 18.150 16.821 iPSCW 3peaker/Strobe 75 0.158 30 280 19.422 18.847 17.928 16.468 iPSCW 3peaker/Strobe 75 0.158 30 310 19.353 18.738 17.754 16.191 iPSCW 3peaker/Strobe 15 0.066 20 330 19.320 18.686 17.670 16.058 iPSCW 3peaker/Strobe 75 0.158 30 360 19.278 18.620 17.565 iPSCW 3peaker/Strobe 30 0.094 30 390 19.256 18.584 17.507 iPSCW 3peaker/Strobe 30 0.094 30 420 19.244 18.566 17.479 iPSCW Total current/amps 0.886 Total Dist:420 voltage drop 1.156 1.834 2.921 J13/2015 15 e SYSTEM SENSOR` sdLdi0lW. Circuit Information Panel Name: FF84 Circuit Name: L-16 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 1s (Amps) last device source (ft) Speaker/Strobe 15 0.066 160 160 19.739 19.351 18.729 17.742 SPSCW Speaker/Strobe 15 0.066 20 180 19.661 19.228 18.533 17.431 SPSCW Speaker/Strobe 15 0.066 20 200 19.589 19.114 18.351 17.141 SPSCW Speaker/Strobe 15 0.066 20 220 19.523 19.008 18.183 16.873 SPSCW Speaker/Strobe 15 0.066 20 240 19.461 18.910 18.027 16.626 SPSCW Speaker/Strobe 15 0.066 75 315 19.251 18.576 17.496 SPSCW Speaker/Strobe 75 0.158 20 335 19.200 18.496 17.367 SPSCW Speaker/Strobe 75 0.158 20 355 19.162 18.435 17.271 SPSCW Speaker/Strobe 75 0.156 20 375 19.136 18.395 17.207 SPSCW Speaker/Strobe 75 0.158 30 405 19.117 18.364 17.158 SPSCW Total current/amps 1.028 Total Dist:405 voltage drop 1.283 2.036 3.242 1/13/2015 16 SYSTEM �.� SENSOR' advanced idem advanced solulam. Circuit Information Panel Name: FF8 5 Circuit Name: L-17 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 1s (Amps) last device source (ft) Speaker/Strobe 15 0.066 130 130 20.124 19.962 19.703 19.291 SPSCW Speaker/Strobe 15 0.066 20 150 20.087 19.903 19.609 19.141 SPSCW Speaker/Strobe 15 0.066 20 170 20.055 19.853 19.528 19.013 SPSCW Speaker/Strobe 15 0.066 20 190 20.029 19.810 19.461 18.907 SPSCW Speaker/Strobe 15 0.066 20 210 20.007 19.777 19.408 16.821 SPSCW Speaker/Strobe 15 0.066 20 230 19.991 19.752 19.367 18.757 SPSCW Speaker/Strobe 15 0.066 250 19.981 19.735 19.341 18.715 SPSCW Speaker/Strobe 15 0.066 J20 270 19.975 19.726 19.327 18.694 SPSCW Total current/amps 0.528 Total Dist: 270 voltage drop 0.425 0.674 1.073 1.706 1/13/2015 17 SYSTEM SENSOR` Circuit Information Panel Name: FF8 5 Circuit Name: L-18 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 18 (Amps) last device source (n) Speaker/Strobe 30 0.094 140 140 20.161 20.021 19.797 19.441 SPSCW Speaker/Strobe 15 0.066 20 160 20.135 19.979 19.730 19.334 SPSCW Speaker/Strobe IS 0.066 30 190 20.103 19.929 19.649 19.206 SPSCW Speaker/Strobe 15 0.066 20 210 20.087 19.903J19.609 19.142 SPSCW Speaker/Strobe 15 0.066 20 230 20.076 19.887 19.099 SPSCW Speaker/Strobe 15 0.066 25 255 20.070 19.876 19.073 SPSCW Total current/amps 0.424 Total Dist:255 voltage drop 0.330 0.524 0.834 1.327 1/13/2015 18 DSYSTEM 40 SENSOR` Circuit Information Panel Name: FF8 5 Circuit Name: L-19 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 1s (Amps) last device source (ft) Speaker/Strobe 15 0.066 200 200 19.900 19.606 19.136 18.390 SPSCW Speaker/Strobe 15 0.066 20 220 19.855 19.535 19.023 16.210 SPSCW Speaker/Strobe 15 0.066 20 240 19.816 19.473 18.924 18.052 SPSCW Speaker/Strobe 15 0.066 35 275 19.756 19.378 18.773 17.812 SPSCW Speaker/Strobe 15 0.066 20 295 19.727 19.332 18.700 17.696 SPSCW Speaker/Strobe 30 0.094 20 315 19.704 19.295 18.641 17.602 SPSCW Speaker/Strobe 15 0.066 35 350 19.676 19.251 18.570 17.490 SPSCW Speaker/Strobe 15 0.066 25 375 19.663 19.230 18.537 17.436 SPSCW Speaker/Strobe 15 0.066 20 395 19.657 19.222 18.523 17.415 SPSCW Total current/amps 0.622 Total DIst:395 voltage drop 0.743 1.178 1.877 2.985 1/13/2015 19 Circuit Information Panel Name: FF8 5 Circuit Name: L-20 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 1416 18 (Amps) last device source (ft) Speaker/Strobe 75 0.158 105 105 20.022 19.800 19.444 18.880 SPSCW Speaker/Strobe 75 0.158 20 125 19.962 19.706 19.294 18.641 SPSCW Speaker/Strobe 75 0.156 40 165 19.869 19.558 19.058 18.266 SPSCW Speaker/Strobe 75 0.158 20 185 19.835 19.504 18.973 18.130 SPSCW Speaker/Strobe 15 0.066 25 210 19.809 19.462 18.906 18.023 SPSCW Speaker/Strobe 15 0.066 25 235 19.789 19.430 18.855 17.943 SPSCW Speaker/Strobe 15 0.066 25 260 19.776 19.409 18.822 17.890 SPSCW Speaker/Strobe )5 0.066 55 315 19.761 19.386 18.785 17.831 SPSCW Total current/amps 0.896 Total Dist:315 voltage drop 0.639 1.014 1.615 2.569 1/13/2015 20 SYS TE OV R' Circuit Information Panel Name: FF8 6 Circuit Name: L-21 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 16 (Amps) last device source (ft) Speaker/Strobe 15 0.066 200 200 19.627 19.172 18.445 17.291 SPSCW 3peaker/Strobe 15 0.066 25 225 19.537 19.030 18.218 16.929 SPSCW 3peaker/Strobe 15 0.066 40 265 19.403 18.818 17.880 16.392 SPSCW 3peaker/Strobe 15 0.066 20 285 19.342 18.720 17.725 16.145 SPSCW 3peaker/Strobe 15 0.066 25 310 19.271 18.609 17.548 SPSCW 3peaker/Strobe 75 0.158 50 360 19.144 18.407 17.227 SPSCW Speaker/Strobe 75 0.158 35 395 19.078 18.301 17.058 SPSCW Speaker/Strobe 75 0.158 35 430 19.033 18.231 16.946 SPSCW Speaker/Strobe 75 0.158 35 465 19.011 18.196 16.890 SPSCW Total current/amps 0.962 Total Dist:465 voltage drop 1.389 2.204 3.510 1/13/2015 21 *� SYSTEM X40 SENSOR' rKWnced ktgm rK1V( w1 solvfions, Circuit Information Panel Name: FF8 6 Circuit Name: L-22 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 16 (Amps) last device source (ft) Speaker/Strobe 75 0.158 130 130 19.932 19.657 19.217 18.518 SPSCW Speaker/Strobe 75 0.158 20 150 19.872 19.563 19.067 18.279 SPSCW Speaker/Strobe 15 0.066 25 175 19.814 19.470 18.919 18.045 SPSCW Speaker/Strobe 15 0.066 20 195 19.773 19.405 18.815 17.679 SPSCW Speaker/Strobe 15 0.066 45 240 19.692 19.276 18.610 17.553 SPSCW Speaker/Strobe 15 0.066 50 290 19.615 19.154 18.416 17.244 SPSCW Speaker/Strobe 75 0.158 25 315 19.583 19.104 18.336 17.117 SPSCW Speaker/Strobe 75 0.158 25 340 19.567 19.079 18.296 17.053 SPSCW Total current/amps 0.896 Total Dist: 340 voltage drop 0.833 1.321 2.104 3.347 1/13/2015 22 Circuit Information Panel Name: FF8 6 Circuit Name: L-23 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 1s (Amps) last device source (ft) ipeaker/Strobe 15 0.066 170 170 19.749 19.367 18.756 17.785 iPSCW ipeaker/Strobe 75 0.158 25 195 19.660 19.226 18.531 17.427 SPSCW ipeaker/Strobe 75 0.158 20 215 19.602 19.133 18.383 17.191 wscw ipeaker/Strobe 75 0.158 20 235 19.556 19.061 18.267 17.007 iPSCW ipeaker/Strobe 75 0.158 20 255 19.523 19.008 18.183 16.874 iPSCW ipeaker/Strobe 15 0.066 30 285 19.492 18.959 18.106 16.751 iPSCW ipeaker/Strobe 30 0.094 20 305 19.477 18.935 18.068 16.690 iPSCW ipeaker/Strobe 30 0.094 20 325 19.470 18.923 18.048 16.660 iPSC W Total current/amps 0.952 Total Dist:325 voltage drop 0.930 1.4771 2.352 3.740 1/13/2015 23 SYSTEM SENSOR' Circuit Information Panel Name: FF8 6 Circuit Name: L-24 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 16 18 (Amps) last device source (ft) Speaker/Strobe 15 0.066 250 250 19.624 19.169 18.439 17.281 SPSCW Speaker/Strobe 30 0.094 65 315 19.440 18.876 17.973 16.540 SPSCW Speaker/Strobe 15 0.066 20 335 19.390 18.798 17,849 16,342 SPSCW Speaker/Strobe 15 0.066 20 355 19.347 18.728 17.738 16.165 SPSCW Speaker/Strobe 15 0.066 20 375 19.308 18.667 17.640 16.010 SPSCW Speaker/Strobe 15 0.066 20 395 19.275 18.614 17.556 SPSCW Speaker/Strobe 15 0.066 20 415 19.247 18.570 17.485 SPSCW Speaker/Strobe 30 0.094 20 435 19.224 18.534 17.428 SPSCW Speaker/Strobe 30 0.094 30 465 19.201 18.498 17.371 SPSCW Speaker/Strobe 30 0.094 30 495 19.190 18.480 17.342 SPSCW Total current/amps 0.772 Total Dist:495 voltage drop 1.210 1.920 3.058 ' 1/13/2015 24 •.,.•:r .: a .-.. .. . .-. Circuit Information Panel Name: FF8 7 Circuit Name: L-25 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class 8 @ 14 AWG DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from Dist from 12 14 1618 (Amps) last device source (ft) ipeaker/Strobe 75 0.158 180 180 19.808 19.461 18.904 18.021 PSCW speaker/Strobe 15 0.066 -20 200 19.755 19.376 18.770 17.807 IPSCW speaker/Strobe 15 0.066 60 260 19.612 19.149 18.408 17.231 iPSCW ipeaker/Strobe 15 0.066 40 300 19.527 19.014 18.193 16.890 iPSCW speaker/Strobe 15 0.066 20 320 19.490 18.955 18.099 16.741 iPSCW ipeaker/Strobe 15 0.066 20 340 19.458 18.905 18.019 16.613 iPSCW ipeaker/Strobe 15 0.066 20 360 19.431 18.863 17.952 16.506 iPSCW ipeaker/Strobe 15 0.066 20 380 19.410 18.829 17.898 16.421 iPSCW ipeaker/Strobe 15 0.066 20 400 19.394 18.804 17.858 16.357 iPSCW ipeaker/Strobe 15 0.066 20 420 19.384 18.787 17.831 16.314 iPSCW ipeaker/Strobe 15 0.066 40 460 19.373 18.770 17.604 16.271 iPSCW Total current/amps 0.818 Total Dist:460 voltage drop 1.027 1.630 2.596 4.129 1/13/2015 25