Compliance Certificate
Project SF4B8 - DAVENPORT
Energy Code:
2012 IECC
Location:
Rexburg, Idaho
Construction Type:
Single-family
Project Type:
New Construction
Orientation:
Unspecified
Conditioned Floor Area:
2,204 ft2
Glazing Area
9%
Climate Zone:
6 (8693 HDD)
Permit Date:
Permit Number:
30
Construction Site: Owner/Agent: Designer/Contractor:
802 S. 2275 W. Kartchner Homes
Summerfeild, Block -8, Lot -4 Logan, UT 84321
RESBURG, ID 83440
Compliance: Passes using JA trade-off
Compliance: 1.0% Better Than Cade Maximum UA: 200 Your UA: 198
The % Better or Worse Than Code Index reflects how close to compliance the house Is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home.
Envelope Assemblies
Ceiling 1: Flat Ceiling or Scissor Truss
1,446
50.0
0.0
0.026
38
Main Wall Front: Wood Frame, 16" D.C.
432
22.0
0.0
0.056
21
Orientation: Front
Window 4: Vinyl/Fiberglass Frame:Double Pane with Low -E
30
0.300
9
Orientation: Front
Door 1: Solid
20
0.170
3
Orientation: Front
Main Wall Right: Wood Frame, 16" o.c.
324
22.0
0.0
0.056
17
Orientation: Right side
Window 7: Vinyl/Fiberglass Frame:Double Pane with Low -E
25
0.300
8
Orientation: Right side
Main Wall Rear: Wood Frame, 16" o.c.
336
22.0
0.0
0.056
15
Orientation: Back
Window 5: Vinyl/Fiberglass Frame:Double Pane with Low -E
51
0.300
15
Orientation: Back
Door 2: Glass
20
0.170
3
Orientation: Back
Main Wall Left: Wool(Frame, 16" o.c.
312
22.0
0.0
0.056
17
Orientation: Left side
BASEMENT WALL FRONT: Wood Frame, 16" o.c.
131
22.0
0.0
0.056
7
Orientation: Front
BASEMENT WALL LEFT: Wood Frame, 16" o.c.
174
22.0
0.0
0.056
9
Orientation: Left side
Project Title: SF4B8 - DAVENPORT Report date: 08/07/17
Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\SF4B8 - DAVENPORT.rck Page 1 of 9
Winoow, 9: Vinyl/Fiberglass Frame:Double Pane with Low -E 20 0.300 6
Orientation: Left side
BASEMENT WALL REAR: Wood Frame, 16" o.c. 156 22.0 0.0 0.056 8
Orientation: Back
Window 8: Vinyl/Fiberglass Frame:Double Pane with Low -E 20 0.300 6
Orientation: Back
Basement - FOUNDATION WALL: Solid Concrete or Masonry 232 0.0 21.0 0.039 9
Orientation: Front
Wall height: 3.0'
Depth below grade: 3.0'
Insulation depth: 3.0'
Crawl 1: Solid Concrete or Masonry 269 0.0 21.0 0.041 7
Wall height: 3.0'
Depth below grade: 3.0'
Insulation depth: 3.0'
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in
REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Date
Project Title: SF4B8 - DAVENPORT Report date: 08/07/17
Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\SF4B8 - DAVENPORT.rck Page 2 of 9
CREScheck Software Version 4.6.2
�J( Inspection Checklist
Energy Code: 2012 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Pre-Inspection/Plan Review
& Req.ID
Plans Verified
Value
Field Verified
Value
Complies? Comments/Assumptions
103.1,
;Construction drawings and❑Complies
103.2
(documentation demonstrate
❑Does Not
[PRl]1
;energy code compliance for the
:building envelope.
❑Not Observable
❑Not Applicable
103.1,
;Construction drawings and❑Complies
103.2,
:documentation demonstrate,❑Does
Not
403.7
;energy code compliance for
[PR3]1
:lighting and mechanical systems. --
:❑Not
Observable
:Systems serving multiple❑Not
Applicable j
:dwelling units must demonstrate
;compliance with the IECC '..
;Commercial Provisions.
302 1,
c,Heating and cooling equipment is
Isized
Heating: Heating: Elcomplies
403.6
[PR2]2
per ACOA Manual S based
;on loads calculated per ACCA
Btu/hr_ I Btu/hr !F
-]Does Not
.0)
J Manual J or other methods
Cooling: ;Cooling: ❑Not Observable
Btu/hr_
approved by the code official,
;Btu/hr_❑Not Applicable
n.anronal Comments/Assumptions:
1 I High Impact (Tier 1) Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: SF4B8 - DAVENPORT Report date: 08/07/17
Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\SF4B8 - DAVENPORT.rck Page 3 of 9
Section
# Foundation Inspection
Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
& Req.ID
402.1.1
(F0411
'Conditioned basement wall ;
'insulation R -value. Where interior;
R-
R-
R -❑Complies See the Envelope Assemblies
',❑Does Not ;table for values.
0'
insulation is used, verification
!may need to occur during❑Not
R- —
Observable
Insulation Inspection. Not
;❑Not Applicable
;required in warm -humid locations
;in Climate Zone 3.
303.2
;Conditioned basement wall
-� ❑Complies
[F05]1
:insulation installed per
❑Does Not
,manufacturer's instructions.
- ❑Not Observable j
❑Not Applicable j
402.2.8
[F0611
;Conditioned basement wall
:insulation depth of burial or
ft
ftI❑Complies ;See the Envelope Assemblies
❑Does Not ;table for values.
;distance from top of wall.
❑Not Observable
j❑Not Applicable
402.2.10
[FO7]1
;Unvented crawl space wall
;insulation R -value.
R-
R -❑Complies ;See the Envelope Assemblies
for
R-
R -_❑Does Not ;table values.
I❑Not Observable
❑Not Applicable
303.2
;Unvented crawl space wall❑Complies
[F08]1
!insulation installed per❑Does
Not
manufacturer's instructions.
❑Not Observable ;
❑Not Applicable
402.2.10
'Unvented crawl space continuous '..❑Complies
[F09]1
'vapor retarder installed over❑Does
Not
exposed earth, joints overlapped-
;by 6 in, and sealed, extending at❑Not
Observable j
:least 6 in. up and attached to the❑Not
Applicable
;wall
402.2.9
F01011
'.. Unvented crawl space wall
'.insulation depth of burial or❑Does
in._
in.❑Complies ;See the Envelope Assemblies
Not ;table for values.
distance from tap of wall.
❑Not Observable
❑Not Applicable
303.2.1
iA protective covering is installed '...❑Complies
[F011]'
to protect exposed exterior'.❑Does
Not
J
insulation and extends a
minimum of 6 in, below grade
!❑Not Observable
!❑Not Applicable
403.8
;Snow- and ice -melting system
!.❑Complies
[F012]2
:controls installed.
❑Does Not
'..❑Not Observable ;
❑Not Applicable j
Additional Comments/Assumptions:
1 I High Impact (Tier 1) Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: SF4B8 - DAVENPORT Report date: 08/07/17
Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\SF4B8 - DAVENPORT.rck Page 4 of 9
# Framing / Rough -In Inspection Plans Verified I Field Verified
& Re .ID Value Value
402.1.1,
Door U -factor. U--
402.3.4
.are determined in accordance
[FR111
;with the NFRC test procedure or
leakage at 75 Pa.
;taken from the default table. _
.402.1.1,
;Glazing U -tactor (area -weighted ; U-
402.3.1,
'average). —
402.3.3,
;3.
402.3.6,
Protection of insulation on HVAC
402.5
403.2.2!All
[FR211
[FR1311
�
I
303.1.3
U -factors of fenestration products-
[FR411
.are determined in accordance
'and labeled to indicate <_2.0 cfm
;with the NFRC test procedure or
leakage at 75 Pa.
;taken from the default table. _
402.4.1.1 ;Air barrier and thermal barrier
[FR2311
.installed per manufacturer's
;®
;instructions.
402.4.3 !Fenestration that is not site built
[FR2011 ;is listed and labeled as meeting
AAMA /WDMA/CSA 101/I.S.2/A440
;or has Infiltration rates per NFRC
1400 that do not exceed code
402.4.4 ,a IC -rated recessed li htin fixtures'
(FR1612 'aealed
;Building cavities are not used
at housing/interior9finish
g/
'and labeled to indicate <_2.0 cfm
leakage at 75 Pa.
403.2.1
'Supply ducts in attics are
[FR1211
insulated to 2!R-8. All other ducts —
;®
in unconditioned spaces or R —
;3.
loutside the building envelope are
Protection of insulation on HVAC
'insulated to all -6.
403.2.2!All
joints and seams _,fair ducts,
[FR1311
lair handlers, and filter boxes are
-
;sealed.
403.2.3
;Building cavities are not used
[FR1511
as
;ducts or plenums.
403.3
'HVAC piping conveying fluids j'
[FR1711
R-
!above 105 4F or chilled fluids
below 55 QF are insulated to l
;3.
403.3.1
Protection of insulation on HVAC
[FR2411
(piping.
403.4.2
Hat water pipes are insulated to R-
[FR18]2>_R-3.
-
�A
R-
R-.
R-,
U-
Complies? I Comments/Assumptions
omplles ;See the Envelope Assemblles
oes Not ; table for values.
Dt Observable
U-- ;❑Complies ;See the Envelop
❑Does Not table for values.
I❑Not Observable
❑Not Applicable
cl�❑Complies
❑Does Not
G5 I €
❑Not Observable
❑Not Applicable
I❑Complies
❑Does Not
❑Not Observable
❑Not Applicable j
❑Complies
❑Does Not
!❑Not Observable
❑Not Applicable
❑Complies
❑Does Not
❑Not Observable
❑Not ADolicahle
'L-IDoes Not
❑Not Observable
❑Not Applicable
❑Compl
❑Does Not
❑Not Observable
❑Not ADolirahla
❑Does Not
❑Not Observable j
pnes
s Not
Observable
LJCor lies
❑Does Not
:❑Not Observable
❑Not ADDlirahla
s Not
Observable
Project Title: SF4B8 - DAVENPORT - ""PdLi t I ier j1
Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\SF468-DAVENPORT.rck Report date: 08/07/17
Page 5 of 9
Section
#
Framing / Rough -In Inspection
Plans Verified
Value
Field Verified
Value Complies?
Comments/Assumptions
& Req.!D
403.5
-Automatic or gravity dampers are '...❑Complies
[FR1912
installed on all outdoor air
❑Does Not
,
intakes and exhausts.
❑Not Observable;
j❑Not Applicable
Auuntionai comments/Assumptions:
1 High Impact (Tier 1) � Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: SF4138 - DAVENPORT Report date: 08/07/17
Data filename: C:\Users\jhoel lei n.MAI N\Documents\REScheck\SF4BEI - DAVENPORT.rck Page 6 of 9
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
3011 All installed insulation is labeled ❑Complies
iIN��4 prthe installed R -values ❑Does Not
.' ',❑Not Observable
Additional Comments/Assumptions:
11 High Impact (Tier 1) r2:. Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: SF4B8 - DAVENPORT Report date: 08/07/17
Data filename: C:WsersUhoellei n -MAI N\Documents\REScheck\SF4B8 - DAVENPORT.rck Page 7 of 9
❑Not Applicable
402.1.1,
402.2.5,
;Wall insulation R -value. If this is a R-
:mass wall with at least 'A of the ; ❑ Wood❑Wood
R-
❑Complies :see the Envelope Assemblies
Does Not table for values.
402.2.6
[IN311
;wall insulation on the wall
:exterior, the exterior insulation ❑Mass
❑Mass
❑Not Observable
(arequirement
applies (FR10). j ❑ Steel
❑ Steel❑Not
Applicable j
303.2
.Wall insulation is installed per
-'❑Complies
[IN4)1
:manufacturer's instructions.
El Does Not
❑Not Observable j
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact (Tier 1) r2:. Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: SF4B8 - DAVENPORT Report date: 08/07/17
Data filename: C:WsersUhoellei n -MAI N\Documents\REScheck\SF4B8 - DAVENPORT.rck Page 7 of 9
Section
#
Final Inspection Provisions
Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
& Req.ID
402.1.1,
(Ceiling insulation R -value.
R-
R -_❑Complies ;See the envelope Assemblles
402.2.1,
j [D Wood
❑ Wood :❑Does Not :table for values.
402.2.2,
402.2.6
❑ Steel
❑ Steel❑Not Observable
[Fill'
❑Not Applicable
303.1.11, ;Ceiling
insulation installed per❑Complies
'
303.2 :manufacturer's
instructions.
` ;-
+u ❑Does Not
[FI211 ;Blown
insulation marked every
ft'.
:'slur -
❑Not Observable
1300
❑Not Applicable
402.2.3 !Vented
attics with air permeable
❑Complies
tFI2212
insulation include baffle adjacent
;_ .4,` -
-.;, ❑Does Not
oto
soffit and eave vents that
over insulation.
-
'r -
❑Not Observable
.'extends
_
❑Not Applicable
402.2.4 (Attic
access hatch and door
R-
R -
[ F1311
insulation all -value of the
j❑Does Not
;adjacent
assembly.
I❑Not Observable
;❑Not Applicable
402.4.1.2
Blower door test @ 50 Pa. <=5
ACH 50 =_
ACH 50=_ ;❑Complies
[FI1711 lath
in Climate Zones 1-2, and
;❑Does Not
�
<=3 ach in Climate Zones 3-8.
:❑Not Observable
❑Not Applicable
403.2.2 ;Duct
tightness test result of <=4
cfm/100
cfm/100❑Complies
[FI411 ]cfm/100
ft2 across the system or
ft'
ft' ;❑Does Not
'handler
<=3 cfm/100 ft2 without air
@ 25 Pa. For rough -in
❑Not Observable
:tests,
verification may need to
-.
;❑Not Applicable
;occur
during Framing Inspection.
403.2.2.1 ;Air handler leakage designated
(❑Complies
[F12411 Iby manufacturer at <=2% of
❑Does Not
,design
airflow.
'..
❑Not Observable
❑Not Applicable
403.1.1
Programmable thermostats
❑Com lies
P
IF 19]2 installed
on forced air furnaces.
-
❑Does Not
9V
❑Not Observable
❑Not Applicable
403.1.2 '..
Heat pump thermostat installed❑Complies
Fl 1012 ;on heat pumps.❑Does
Not
�
❑Not Observable
I❑Not Applicable
403.4.1 ;Circulating service hot water
❑Complies
[F:11]' -.systems have automatic or
[:]Does Not
accessible manual controls.
❑Not Observable
❑NotApplicable
403.5.1 A:: mechanical ventilation system -.❑Complies
[FI25]' Mans
not part of tested and listed
❑Does Not
: HVAC equipment meet efficacy
l and air flow limits.
j Not Observable
- ❑
❑Not Applicable
404.1 75% of lamps in permanent
Complies
[FI611 fixtures or 75% of permanent❑Does
;fixtures have high
Not
efficacy lamps.
: Does not apply to low -voltage
❑Not Observable
(lighting.❑Not
Applicable
1 I High Impact (Tier 1) Medium Impact (Tier 2) $ Low Impact (Tier 3)
Project Title: SF4B8 - DAVENPORT Report date: 08/07/17
Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\SF4B8 - DAVENPORT.rck Page 8 of 9
Section
#
Final Inspection Provisions
Plans Verified
Value
Field Verified
Value Complies?
Comments/Assumptions
& Req.ID
404.1.1
Fuel gas lighting systems have
;❑Complies
[FI23]3
no continuous pilot light.
❑Does Not
❑Not Observable
;i❑Not Applicable
401.3
.Compliance certificate posted.
-;❑Complies
[FI712
'...❑Does
Not
❑Not Observable
❑Not Applicable
303.3
Manufacturer manuals for
iOComplies
[FI18]3
'mechanical and water heating
- ,I❑Does Not
systems have been provided..
-❑Not Observable
❑Not Applicable :
Additional Comments/Assumptions:
111 High Impact (Tier 1) [1
1 Medium Impact (Tier 2) 13 Low Impact (Tier 3)
Project Title: SF4B8 - DAVENPORT Report date: 08/07/17
Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\SF4B8 - DAVENPORT.rck Page 9 of 9
2012 IECC Energy
Efficiency Certificate
Above -Grade Wall
22.00
Below -Grade Wall
21.00
Floor
0.00
Ceiling / Roof
50.00
Ductwork (unconditioned spaces):
Window 0.30
Door
0.17
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments