Loading...
HomeMy WebLinkAboutCOMCHECK - 17-00457 - Super Cuts - Tenant FinishCOMcheck Software Version 4.0.5.1 Interior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: Construction Site: 1480 N. 2nd St. E. Suite 120 Rexburg, ID 83440 Allowed Interior Lighting Power 2012 IECC Supercuts Alteration Owner/Agent: Regis Corporation 7201 Metro Blvd. Minneapolis, MN Designer/Contractor: Dunham Associates 50 South 6th St. Suite 1100 Minneapolis, MN 55402 A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B X C) 1 -Sales (Retail:Sales area) 877 1.60 1403 2 -Storage (Common Space Types:Storage) 183 0.80 146 3 -Restroom (Common Space Types:Restroom) 53 1.00 53 4 -Office (Common Space Types:Office - Enclosed) 57 1.10 63 Total Allowed Watts = 1665 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Sales ( Retail:Sales area 877 sa ft ) LED 1: A,Al: LED 2X4 Panel: Other: 2 10 64 640 Track lighting 1: Wattage based on current limiting device capacity 0 0 1320 360 Storage ( Common Space Tvoes;Storage 18s03f) LED 1: A,Al: LED 2X4 Panel: Other: 2 3 64 192 Restroom ( Common Space Tvnes:Restroom 53 sa.ft.) Incandescent 1: EX/L: Fan/Light Combo: Incandescent 60W: 1 1 60 60 ) Office (Common Space Types•Office - Enclosed 57 sq.ft.) LED 1: A,Al: LED 2X4 Panel: Other: 2 1 64 - 64 Total Proposed Wafts = 1316 Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the2012IECC requirements in COMcheck Version 4.0.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Project Title: Supercuts Report date: 03/30/17 Data filename: P:\2017\0417970-022-00 Supercuts - Rexburg, ID\03-Electrical\02-Lighting\22-20121ECC.cck Page 1 of 7 Mark J. Azure, P.E. 7/17/17 Project Title: Supercuts Report date: 03/30/17 Data filename: P:\2017\0417970-022-00 Supercuts - Rexburg, ID\03-Electrical\02-Lighting\22-20121ECC.cck Page 2 of 7 COMcheck Software Version 4.0.5.1 Inspection Checklist Energy Code: 2012 IECC Requirements: 94.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. `Section # & Req.ID. Plan Review 1 Complies? Comments/Assumptions C103.2 iPlans, specifications, and/or❑Complies 'Requirement will be met. [PR4]1 :calculations provide all information ❑Does Not ;with which compliance can be :determined for the interior lighting f❑Not Observable' and electrical systems and equipment❑Not Applicable and document where exceptions to :the standard are claimed. Information ' provided should include interior ` (lighting power calculations, wattage of bulbs and ballasts, transformers and 'control devices. Additional Comments/Assumptions: 1 High Impact (Tier 1) 12:;1 Medium Impact (Tier 2) 3ow Impact (Tier 3) Project Title: Supercuts Report date: 03/30/17 Data filename: P:\2017\0417970-022-00 Supercuts - Rexburg, ID\03-Electrical\02-Lighting\22-20121ECC.cck Page 3 of 7 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions 0405.2.2. `: Automatic controls to shut off all ❑Complies Requirement will be met. 1 _":building lighting installed in all❑Does Not [EL22]2. buildings. ❑Not Observable' ❑Not Applicable 0405.2.1..! Independent lighting controls installed❑Complies : Requirement will be met. 1 per approved lighting plans and all ❑Does Not [EL23]' manual controls readily accessible and'❑Not Observable' '.visible to occupants. ❑Not Applicable _ C405.2.1. Lighting controls installed to uniformly ❑Complies ! Requirement will be met. 2 reduce the lighting load by at least ❑Does Not [EL15]1 -50%. :[-]Not Observable; ❑Not Applicable ? _ C405.2.2. ! Daylight zones provided with :❑Complies 'Requirement will be met. 3 individual controls that control the ❑Does Not - (EL16]2 lights independent of general area ❑Not Observable' ::..'lighting. ❑Not Applicable _ C405.2.3 iSleeping units have at least one ❑complies :Exception: Requirement does not apply. [EL17]3 -.:� master switch at the main entry door ❑Does Not l that controls wired luminaires and ❑Not Observable. -;switched receptacles. ❑Not Applicable C405.2.2. Occupancy sensors installed in :❑Complies 'Requirement will be met. 2 ;required spaces. !❑Does Not [EL1811 �❑Not Observable ❑Not Applicable C405.2.2. 'Primary sidelighted areas are ❑Complies 'Exception: Requirement does not apply. 3 equipped with required lighting ❑Does Not [EL20]1 ;controls.❑Not Observable' ❑NotApplicable C405.2.2. Enclosed spaces with daylight area Y❑Complies ^ Exception: Requirement does not apply. 3under skylights and rooftop monitors❑Does Not [EL21]1 :are equipped with required lighting❑Not Observable; controls. ❑Not Applicable 0405.2.3 ! Separate lighting control devices for '❑Complies Requirement will be met. [EL4]1 ;specific uses installed per approved ❑Does Not ;lighting plans. ❑Not Observable. i❑Not Applicable C405.3 'I Fluorescent luminaires with odd❑Complies ;Exception: Requirement does not apply. [EL19]3 ' numbered lamp configurations that ❑Does Not I are within 10 feet center to center (if i ,❑Not Observable. recess mounted) or are within 1 foot Applicable edge to edge (if pendant or surface❑Not mounted) shall be tandem wired. C405.4 li Exit signs do not exceed 5 watts peri❑Complies _ Exception: Requirement does not apply. [EL6]1 face. '❑Does Not ❑Not Observable: UNot Applicable C405.2.3 j Additional interior lighting power i❑Complies Requirement will be met. [EL8]1 allowed for special functions per the '❑Does Not approved lighting plans and is ![]Not Observable. automatically controlled and -separated Applicable from general lighting.❑Not Additional Comments/Assumptions: 11 High Impact (Tier 1)_2.: Medium Impact (Tier 2) (. `3!1 Low Impact (Tier 3) Project Title: Supercuts Report date: 03/30/17 Data filename: PA2017\0417970-022-00 Supercuts - Rexburg, ID\03-Electrical\02-Lighting\22-20121ECC.cck Page 4 of 7 1 High Impact (Tier 1) J 2._ Medium Impact (Tier 2) ! 3' Low Impact (Tier 3) Project Title: Supercuts Report date: 03/30/17 Data filename: P:\2017\0417970-022-00 Supercuts - Rexburg, ID\03-Electrical\02-Lighting\22-20121ECC.cck Page 5 of 7 Section I # Final Inspection Comphes7 i Comments/Assumptions C408.2.5. Furnished as-built drawings for ❑Complies Requirement will be met. 1 electric power systems within 30 days❑Does Not [FI16]' ,of system acceptance. '[]Not Observable ❑Nat Applicable C303.3, Furnished O&M instructions for❑Complies :Requirement will be met. C408.2.5:. systems and equipment to the❑Does Not 2.' • building owner or designated ❑Not Observable. [FI17]';representative. ❑Not Applicable C405.5.2 : Interior installed lamp and fixture '❑Complies :See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ::E] Does Not is shown on the approved lighting i❑Not Observable; ;plans, demonstrating proposed watts ❑Not Applicable ; are less than or equal to allowed 1 watts. C408.3 ;:Lighting systems have been tested to i❑Complies :Requirement will be met. [FI33]1 !ensure proper calibration, adjustment, :❑Does Not :programming, and operation. ❑Not Observable; ❑Not Applicable C406 i Efficient HVAC performance, efficient ❑Complies (F134]1 ;lighting system, or on-site supply of ❑Does Not ,. 'renewable energy consistent with i❑Not Observable; - -what is shown the approved plans. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) -2 Medium Impact (Tier 2) _j_ 3 1 Low Impact (Tier 3) Project Title: Supercuts Report date: 03/30/17 Data filename: P:\2017\0417970-022-00 Supercuts - Rexburg, ID\03-Electrical\02-Lighting\22-20121ECC.cck Page 6 of 7 Project Title: Supercuts Report date: 03/30/17 Data filename: P:\2017\0417970-022-00 Supercuts - Rexburg, ID\03-Electrical\02-Lighting\22-20121ECC.cck Page 7 of 7 �- I