HomeMy WebLinkAboutSTRUCTURAL CALCULATIONS - 407 W 1st N - Homestead Bldg 3 - Addition
Structural Calculations
for
Homestead Assisted Living Building 3 Addition
Rexburg Idaho
Scope of Work: Foundations and Pedestal Framing
Project - Number
June, 2017
Homestead 3 - Page 1 of 18
06/24/2017
TBSE 1 of 1
Homestead 3 Notes
Design notes/comments to help understand the design philosophy and steps:
2017 06 24
1. Footing and foundation package sent in before entire building was designed. Therefore, included in that package
was enough of the lateral calculations to understand the overturning effect of the lateral system along with enough of
the vertical loads to properly size the footings.
Hold downs were required at the interior wall ends. The 2 interior bearing wall lines were increased in size (from just
the gravity) to incorporate the uplift forces. Top and bottom steel is in these footings.
The exterior footings have the frost wall to spread overturning forces out and to have positive and negative moment
strength.
2. Allowable bearing pressure of 1500 psf was used as there is no soil's report specifically for this addition. A
previous soils report indicated bearing upto 2500 psf could be obtained with soil removal/structural fill replacement, but
with the light loads and residential like construction, the lower bearing pressure was used.
3. Complete calculations will be provided with the entire package submittal.
4. Bolting for walls - Interior walls will use titen HD anchors after casting of floor. Exterior walls are intended to have
bolts cast (although we all an option for the contractor to use titen HD anchors there also).
5. Two types of interior footings were used: 1) is cast intergal to the slab, or thickened slab footing. These are along
the non-bearing shear wall lines, 2) is a 2 pour footing. The footing is cast lower than the slab seperately, then the
slab is cast over the top. This allows better quality assurance for this footing has positive and negative bending and is
the bearing of most of the roof.
DLB 6/24/2017 Homestead 3 Notes.xmcd
Homestead 3 - Page 2 of 18
TBSE Inc.
TBSE Inc.
STRUCTURAL ENGINEERS
233 North 1250 West, #201 PROJECT:Homestead 3
Centerville, Utah 84014 Our Job #:
Phone 801-298-8795 Engineer:DLB
Fax 801-298-1132 Date:6/24/2017
Arch:
DESIGN CRITERIA USED
International Building Code Used 2012
Risk Category = III
Dead Loads: Roof 25 psf
Floor -psf
Live Loads: Roof 20 psf Snow Drift included where required
1st Floor Corridor/Lobby -psf Reducible Live Load
Rooms -
Snow Loads Ground 50 psf
Roof 38.5 psf
Ce 1.00
Is 1.10
Ct 1.00
Wind: Wind Exposure =B
Ultimate Wind Speed =120 mph
Pressure used =Various psf
Internal Pressure Coef. =0.18 + or -
Component and Cladding =Various psf at corners
Seismic Force Resisting System:Light frame walls with wood structural panels
Vertical Irregularities Plan Irregularities
None 2
Seismic Design Procedure Equivalent
Seismic Response Coef. Cs 0.08 g
Portion of Snow Included 0 %
Soil Site Class D
Seismic Design Category C
R =6.5
Omega =3
Cd =4
Ie =1.25
Ss =0.44
S1 =0.16
SDs =0.43
SD1 =0.23
Geotechnical:
Allowable Soil Pressure 1500 psf (Max.)
1500 psf (Min.)
Active Lateral Earth Pressure NA pcf
At Rest NA pcf
Passive NA pcf
Friction Coefficient -
Soil Weight 120 pcf
Frost Depth 36 inches Min. Use 42
MATERIAL AND STRENGTH REQUIREMENTS
Concrete: Design Weight 150 pcf Columns 4000 psi
Footings 4500 psi Elevated Decks 4000 psi
Foundation Walls 4500 psi Beams -psi
Slabs on Grade 4000
Interior 4000 psi
Exterior 4500 psi w/ 6% Air +/- 1%
Masonry:f'm =1500 psi
Mortar Type:S
Is Special Inspection Required? =No
Steel: Beams 50 ksi Columns:
PL's NA ksi Pipe ksi
Ledger Bolts NA Tube 46 ksi
Foundation Bolts 55 Rolled Sections 50 ksi
Steel to Steel Bolts 60
Reinf Steel: Concrete & Masonry Construction -ksi
Wood: Joist or Post Species NA Grade No.2 or Better
Glu-Lam's:Fb =NA psi E =NA psi
LVL's:Fb =NA psi E =NA psi
PSL's:Fb =NA psi E =NA psi
APA Rated Roof Sheathing: Panel Index NA NA " thickness or equivalent
APA Rated Floor Sheathing: Panel Index NA NA " thickness or equivalent
APA Rated Wall Sheathing: Panel Index NA NA " thickness or equivalent
SDC 6/24/2017
Homestead 3 - Page 3 of 18
Homestead 3 - Page 4 of 18
TBSE 1 of 4
Input IBC 2012
Updated: 2013 08 27
OccCat
IE
IS
IW
Ss
S1
SC
R
Ω
Cd
Inp1
Project: Homestead 3
ID:
ASCE 7-10
Occupancy Category 3
Seismic Use Group II
Importance Factors suggestion
IE 1.25 1.25
IS 1.10 1.1
IW 1.00 1
Seismic SS 0.44 g
S1 0.156 g
Site Class D D 4
5
R 6.5 6.5
W 3.0 3
Cd 4.0 4
Ht 10 ft
CT 0.02 0.02 gen., 0.03 EBF, 0.028 SMRF, 0.016 Conc MRF
x 0.75 0.75 gen., 0.8 SMRF, 0.9 Conc MRF
rho 1
Regular Bldg Y "Y"es or "N"o
TL 6 (8 Wasatch Front, 6 UT) See Fig 22-12
:=
Ht Inp10 ft:=CT Inp11:=xperiod Inp12:=ρ Inp13:=REG Inp14:=TL Inp15:=
OccCat 3=IE 1.25=IS 1.1=IW 1=TL 6=
DLB 6/24/2017 Input IBC2012 Homestead 3.xmcd
Homestead 3 - Page 5 of 18
TBSE 2 of 4
Map Ss (0.2 second)Ss 0.44=
Map S1 (1 second)S1 0.156=
Site Class SC "D"=
Seismic Use Group SUG if OccCat 1=1, OccCat 1-, ( ):=SUG 2=
R (Table 1617.6)R 6.5=
TabFa
0.8
1.0
1.2
1.6
2.5
0.8
1.0
1.2
1.4
1.7
0.8
1.0
1.1
1.2
1.2
0.8
1.0
1.0
1.1
0.9
0.8
1.0
1.0
1.0
0.9
:=W (Table 1617.6)Ω 3=
Cd (Table 1617.6)Cd 4=
Building Height Ht 10ft=
Period Coefficient CT 0.02=
Period "x" factor xperiod 0.75=
TabFv
0.8
1.0
1.7
2.4
3.5
0.8
1.0
1.6
2.0
3.2
0.8
1.0
1.5
1.8
2.8
0.8
1.0
1.4
1.6
2.4
0.8
1.0
1.3
1.5
2.4
:=Redundancy ρ 1=
Regular 5 stories or less REG "Y"=
Find interpolated table values for Fa and Fv
r if SC "A"=0, if SC "B"=1, if SC "C"=2, if SC "D"=3, if SC "E"=4, 999, ( ), ( ), (), (), ():=r 3=
ac1 ceil
Ss
.25
1-
:=ac1 1=ac2 floor
Ss
.25
1-
:=ac2 0=ac2 if ac2 4>4, if ac2 0<0, ac2, ( ), ( ):=
ac1 if ac1 4>4, ac1, ( ):=ac1 1=a_int Ss
.25
ac1-:=a_int 0.76=
vc1 ceil
S1
.1
1-
:=vc1 1=vc2 floor
S1
.1
1-
:=vc2 0=vc2 if vc2 4>4, if vc2 0<0, vc2, ( ), ():=
vc1 if vc1 4>4, vc1, ( ):=vc1 1=v_int S1
.1
vc1-:=v_int 0.56=
Fa1 TabFar ac1, :=Fa1 1.40=Fa2 TabFar ac2, :=Fa2 1.60=Fa Fa2 Fa2 Fa1-( ) a_int-:=
Fv1 TabFvr vc1, :=Fv1 2.00=Fv2 TabFvr vc2, :=Fv2 2.40=Fv Fv2 Fv2 Fv1-( ) v_int-:=
T CT Ht ft
1-( )
xperiod
:=(12.8.2.1)T 0.112=Fa 1.45=Fv 2.18=
SMS Fa Ss:=(11.4-1)SMS 0.637=
SM1 Fv S1:=(11.4-2)SM1 0.339=
SDS 2
3
SMS:=(11.4-3)SDS 0.425=
SD1 2
3
SM1:=(11.4-4)SD1 0.226=
DLB 6/24/2017 Input IBC2012 Homestead 3.xmcd
Homestead 3 - Page 6 of 18
TBSE 3 of 4
Cs SDS
R
IE
:=(12.8-2) Calculated Cs 0.082=
Csmax1 SD1
R
IE
T
:=(12.8-3) Maximum Csmax1 0.387=
Csmax2
SD1 TL
R
IE
T2
:=(12.8-4) Maximum Csmax2 20.643=
Csmax if T TL>Csmax2, Csmax1, ( )
:=Csmax 0.387=
Csmin 0.01:=(12.8-5) Minimum Csmin 0.010=
Csmin2 0.5
S1
R
IE
:=(12.8-6) when in E or F Csmin2 0.015=
E if Csmax Cs<Csmax, if Csmin Cs>Csmin, Cs, ( ), ():=
E if SC "E"=if Cs Csmin2<Csmin2, E, ( ), if SC "F"=if Cs Csmin2<Csmin2, E, ( ), E, (), ():=(12.8.1.1)
E (Chose appropiate Cs)E 0.082=E
1.4
0.058=
Vertical Component (Mainly LRFD Methods)
Evert if SDS 0.125£0, 0.2 SDS, ( ):=(12.14.3.1.2)Evert 0.085=
Calculate the Seismic Design Category (TABLES 11.6-1 & 11.6-2)
i_SDS ceil SDS 6( ):=SDS 0.425=i_SDS 3=
i_SD1 ceil SD1 15( ):=SD1 0.226=i_SD1 4=
i if i_SDS i_SD1>i_SDS, i_SD1, ( ):=i 4=
SDtab1
"A"
"B"
"C"
"D"
:=SDtab2
"A"
"C"
"D"
"D"
:=i if i 4>3, i 1-, ( ):=i 3=
SDC if SUG 3=SDtab2i, SDtab1i, ( )
:=
SDC if S1 0.75>if SUG 3="F", "E", ( ), SDC, ( ):=SDC "D"=
SDCSDSonly SDtab1i_SDS 1-:=SDCSDSonly "C"=
DLB 6/24/2017 Input IBC2012 Homestead 3.xmcd
Homestead 3 - Page 7 of 18
TBSE 4 of 4
Diaphragm Force
Fp_diaphragm_min 0.2 SDS ρ IE 1.4‚:=(12.10.1.1)Fp_diaphragm_min 0.076=
Fp_diaphragm_max 0.4 SDS ρ IE 1.4‚:=(12.10.1.1)Fp_diaphragm_max 0.152=
Collector Elements
Collector_Factor Ω:=(12.10.2.1)Collector_Factor 3=
(Category C-F)
Structural Walls and their anchorage
Fp_wall max 0.4 SDS IE 0.1, ( )
1.4‚:=(12.11.1)Fp_wall 0.152=
Concrete or masonry walls have a minimum of 200 plf (working stress) spaced 4' or closer w/o designing resistance
between anchors.
Anchorage of Conc. or Mas. Walls to Flexible Diaphragms
Fp_wall_conc_and_mas 0.8 SDS IE 1.4‚:=(9.5.2.6.1.1)Fp_wall_conc_and_mas 0.303=
(Category C-F)
Building Drift
DLB 6/24/2017 Input IBC2012 Homestead 3.xmcd
Homestead 3 - Page 8 of 18
TBSE Simplified Wind Design
Wind Design Loads for the Main Wind Force Resisting System
IBC 2012 (section 1609) / ASCE 7-10 Section 28.5 & 30.5 ASD
Note: Check ASCE 7-10 sections 28.5 & 38.5 for limitations Simplified Method OK
Eave Ht 9
Eave Height =9.0 ft Wall L 150
Mean Roof Height =20.0 ft
Least horizontal Dimension =69.0 ft
Ultamate Wind Speed =120 mph : 3 second gust speed Mean Roof Ht 20 ridge
Exposure =B Wall L 69
Hurricanine Prone Region ?N
Roof Angle =30.0 degrees max = 45 degrees
Kzt = 1 per section 26.8 ASCE 7-10
ASD or LRFD Load Factor =0.6 (0.6 or 1.0)
l =1 1 Lesser of No Less than
Edge Strip (a) = 3.6 6.9 3.6 2.76 3
End Zone (2a) = 7.2
Avg L Avg Up
A B C D E F G H
EOH GOH A & C A & C
Load Case 1 15.4 10.6 12.2 8.4 1.2 -9.4 0.4 -8.0 -5.4 -6.2 12.6 12.4
Load Case 2 15.4 10.6 12.2 8.4 5.9 -4.6 5.2 -3.3 -5.4 -6.2
Overhang
Adjusted Main Windforce-Restisting System Loads (psf)
Load Direction
Horizontal Loads Vertical Loads
End Zone Interior End Zone Interior Zone
LJB 6/24/2017
Homestead 3 - Page 9 of 18
TBSE Simplified Wind Design
Zone Area
1 10 14.2 -15.5
20 13.8 -14.8
50 13.3 -13.7
100 12.9 -12.9
2 10 14.2 -18.2
20 13.8 -17.4
50 13.3 16.3
100 12.9 -15.5
3 10 14.2 -18.2
20 13.8 -17.4
50 13.3 -16.3
100 12.9 -15.5
4 10 15.5 -16.9
20 14.8 -16.1
50 13.9 -15.2
100 13.2 -14.5
500 11.6 -12.9
5 10 15.5 -20.8
20 14.8 -19.4
50 13.9 -17.6
100 13.2 -16.1
500 11.6 -12.9
Roof Overhangs
2 10 -24.2
20 -23.5
50 -22.5
100 -21.8
3 10 -24.2
20 -23.5
50 -22.5
100 -21.8
Pressure
LJB 6/24/2017
Homestead 3 - Page 10 of 18
TBSE 1 of 2
HOMESTEAD 3 Lateral
WindPressure 21psf:=Full W, not 0.6W
Cs 0.082:=
RDL 25psf:=
L 147ft:=
W 69ft:=
WallDL 20psf:=
Wallht 9ft:=
Wt L W RDL 2 L W+( )Wallht WallDL+331.34 kips=:=
E Cs Wt 27.17 kips=:=0.7 E 19.02 kips=
W1 WindPressure 145ft 9
2
ft 24ft+
86.78 kips=:=0.6 W1 52.07 kips=
W2 WindPressure 69ft 9
2
ft 24
2
ft+
23.91 kips=:=0.6 W2 14.35 kips=
DLB 6/24/2017 Lateral - Homestead 3.xmcd
Homestead 3 - Page 11 of 18
TBSE 2 of 2
Wind controls Up Down (in orientation shown on previous page) and EQ controls Left-Right
Use the interior wall in the Up Down direction
Wall1 0.6 W1
22.5 6.5+( )ft
2 147ft
5.14 kips=:=
Wall3 0.6 W1
22.5 6.5+15.75+( )ft
2 147ft
7.93 kips=:=
Wall3.5 0.6 W1
15.75 31.5+( )ft
2 147ft
8.37 kips=:=
Wall4.5 0.6 W1
31.5 31.5+( )ft
2 147 ft
11.16 kips=:=
Wall5.5 0.6 W1
31.5 31.5+( )ft
2 147 ft
11.16 kips=:=
Wall6 0.6 W1
15.75 23.5+( )ft
2 147ft
6.95 kips=:=22.5 6.5+15.75+31.5+31.5+15.75+23.5+147.00=
Wall7 0.6 W1
0 23.5+( )ft
2 147 ft
4.16 kips=:=
WallA 0.7 E
2
9.51 kips=:=
Check worst wall: That appears to be grid 4:
V Wall4.5 11.16 kips=:=WallL 25 15.9+( )ft 40.90ft=:=V
WallL
272.81 plf=:=
Wallht 9 23
8
2 12
+
ft 16.67ft=:=OTF Wallht 0.6 15psf 23
2
ft Wallht-2.82 kip=:=
ftg_t 6 12+( )in 18.00 in=:=req_size OTF
ftg_t 150 pcf
3.54ft=:=
Use 4' square footing with HDU2 Hold down.
Wall shear along Grid A was designed using Enercalc.
Strap above and below openings to allow aspect ratios
No Hold Downs are required
0.7 E
141ft 4 7 5.33+3 3+( )ft-[ ]2
104.86 plf=:=
DLB 6/24/2017 Lateral - Homestead 3.xmcd
Homestead 3 - Page 12 of 18
Homestead 3 - Page 13 of 18
Homestead 3 - Page 14 of 18
Homestead 3 - Page 15 of 18
Homestead 3 - Page 16 of 18
Homestead 3 - Page 17 of 18
Homestead 3 - Page 18 of 18