SUMMARY INSPECTION REPORT
This letter is to confirm that, in accordance with Chapter 17 of the 2012 International Building Code, the project
specifications, and the project scope of services, Materials Testing & Inspection personnel have performed
special inspections of the following items:
• Soil Compaction
• Reinforced Concrete
• Epoxy
• Structural Steel
We confirm that, to the best of our knowledge, the requirements of the 2012 International Building Code and
the approved plans and specifications have been complied with, insofar as meeting the portion of the
aforementioned inspections requiring special inspection under Chapter 17 of the IBC, except as noted below:
Concrete placed on April 22, 2014 for stemwall on gridlines 1-10 and rows B-H was out of the specified
air requirements per report rpt019rc. 28 -day break tests for this concrete exceeded the specified psi.
Pull tests for all -thread anchors located at gridline 4 row c.5, gridline 5.4 row B, and gridline 5.75 row
C.25 failed to reach the specified minimal value and hold per report rpt026. Per rpt028ep epoxy
inspection took place on May 23, 2014 for the reinstallation of the failing bolts, additional pull tests did
not occur.
Tests and inspections were performed only when MTI was scheduled to do so. A guarantee that the contractor
has necessarily constructed the structure in full accordance with the plans and specifications is neither
intended nor implied
If there are questions concerning this letter (rpt036summaryinspection) or if MTI can be of further assistance,
please contact the project manager at (208) 529-8242. _`N
qt
Respectfully submitted,
MATERIALS TESTING & INSPECTION, INC.
Justin Hacking Reviewed by: Chris A. Park, P.E. j� P�