HomeMy WebLinkAboutDENSITY OF SOIL REPORT 15 - 14-00050 - Idaho Central Credit Union
ASTM D-6938
Density of Soil and Soil-Aggregate in Place by
Nuclear Methods (Shallow Depth)
PAGE #1 OF 1
REPORT DATE 4/25/2014
R:\Eastern Idaho\2014
Reports\E140030c - Idaho Central
Credit Union, 673 North 2nd East,
Rexburg, ID\rpt020md.docx
Environmental Services Geotechnical Engineering Construction Materials Testing Special Inspections
1230 N Skyline Drive, Suite C Idaho Falls, ID 83402 (208) 529-8242 Fax (208) 529-6911
www.mti-id.com mti@mti-id.com Rev. January 21, 2014
M AT E RI ALS
TESTI NG &
INSPECTION
Dustee Woolstenhulme Phone: 208-239-3003
Idaho Central Credit Union Fax: 208-239-3053
PO Box 2469 Other: EMAIL ONLY
Pocatello, ID 83206
Project: Idaho Central Credit Union, 673 North
2nd East, Rexburg, ID
Permit #:
Project Manager: Dan King
Inspector: Josh Christensen
Inspection Date: April 24, 2014
As requested, MTI performed density testing in accordance with current applicable standards. The results
obtained are as follows:
145056 1 Pit Run 127.2 7.5%
Test #
Probe
Depth
(in)
Location
Wet
Density
(pcf)
%
Moisture
Dry
Density
(pcf)
Material #
Required
%
Compaction
%
Compaction Pass/Fail
1 8
8" below finish subgrade,
exterior wall footing backfill:
line D.3 and 8
126.3 3.6%121.8 1 95%96%PASS
2 8 Line D.5 and 7 126.4 3.3%122.4 1 95%96%PASS
3 8 Line D.9 and 2 126.4 3.4%122.2 1 95%96%PASS
Lab ID
#
Material
#Material Description Material Source
Maximum
Density
(pcf)
Optimum
Moisture Standard Used
Zollinger Pit Onsite Stockpile ASTM D-1557
Method of Testing: BS is Backscatter; Depth in inches is Direct Transmission
Gauge Information:
MTI #:17 Make & Model:Troxler 3440 Serial #:34596 Standard Counts:DS:2283 MS:730
If there are questions concerning this report (rpt020md), please contact the project manager at (208) 529-8242.
Respectfully submitted,
MATERIALS TESTING & INSPECTION, INC.
Reviewed by Gavin J Marron
cc: Rodger Ford, CM Company; Tom Callsen, CM Company