Project: Idaho Central Credit Union, 673 North
2nd East, Rexburg, ID
Permit #:
Project Manager: Dan King
Inspector: Troy McMurtrey
Inspection Date: April 22, 2014
REINFORCED CONCRETE INSPECTION REPORT
On the above date, our representative performed work on the referenced project as reported below.
Inspected reinforcing steel placement at the stemwall on gridlines 1-10 and rows B-H.
Monitored concrete arriving at the jobsite for correct mix, and performed one air content test and one slump
test. Observed placement and consolidation of 27.75 cubic yards of Burns concrete mix #355075-1 placed at the
same location stated above, and cast one set of four cylinders.
Cylinders: #00627-#00630
Work inspected was in compliance with project plans and specifications, except as noted.
Notes: Air content specifications are 5.0% ± 1.5%, and tested at 3.2%. Contractor was notified and placement
continued.
If there are questions concerning this report (rpt019rc), please contact the project manager at (208) 529-8242.
Respectfully submitted,
MATERIALS TESTING & INSPECTION, INC.
Reviewed by Gavin J Marron