HomeMy WebLinkAboutEPOXY INSPECTION REPORT - 14-00050 - Idaho Central Credit Union PAGE #1 OF 1 PRINT DATE 4/18/2014 R:\Eastern Idaho\2014 Reports\E140030c - Idaho Central Credit Union, 673 North 2nd East, Rexburg, ID\rpt018ep.docx  Environmental Services  Geotechnical Engineering  Construction Materials Testing  Special Inspections 1230 N Skyline Drive, Suite C  Idaho Falls, ID 83402  (208) 529-8242  Fax (208) 529-6911 www.mti-id.com  mti@mti-id.com Revised February 2011 M AT E RI ALS TESTI NG & INSPECTION Dustee Woolstenhulme Phone: 208-239-3003 Idaho Central Credit Union Fax: 208-239-3053 PO Box 2469 Other: EMAIL ONLY Pocatello, ID 83206 Project: Idaho Central Credit Union, 673 North 2nd East, Rexburg, ID Permit #: Project Manager: Dan King Inspector: Chris Park Inspection Date: April 17, 2014 EPOXY INSPECTION REPORT On the above date, our representative performed work on the referenced project as reported below. Inspected 18 drilled holes to a depth of 7 inches and a diameter of 7/8 inches for 5/8 inch x 3 foot 7 inch dowels to be installed at D10 (2), E10 (4), H5.5 (4), F1 (4), and D1 (4). MTI confirmed that the holes were cleaned by blow out, and are ready for epoxy and dowels installation. Observed injection of Hilti Hit HY 200 epoxy into the holes. MTI witnessed installation of 18 dowels into the holes, and confirmed they received sufficient coating of epoxy. Work inspected was in compliance with project plans and specifications. Notes: An RFI is pending. If there are questions concerning this report (rpt018ep), please contact the project manager at (208) 529-8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. Reviewed by Gavin J Marron cc: Rodger Ford, CM Company; Tom Callsen, CM Company