HomeMy WebLinkAboutDENSITY OF SOIL REPORT 6 - 14-00050 - Idaho Central Credit Union
ASTM D-6938
Density of Soil and Soil-Aggregate in Place by
Nuclear Methods (Shallow Depth)
PAGE #1 OF 2
REPORT DATE 3/28/2014
R:\Eastern Idaho\2014
Reports\E140030c - Idaho Central
Credit Union, 673 North 2nd East,
Rexburg, ID\rpt007md.docx
Environmental Services Geotechnical Engineering Construction Materials Testing Special Inspections
1230 N Skyline Drive, Suite C Idaho Falls, ID 83402 (208) 529-8242 Fax (208) 529-6911
www.mti-id.com mti@mti-id.com Rev. January 21, 2014
M AT E RI ALS
TESTI NG &
INSPECT ION
Dustee Woolstenhulme Phone: 208-239-3003
Idaho Central Credit Union Fax: 208-239-3053
PO Box 2469 Other: EMAIL ONLY
Pocatello, ID 83206
Project: Idaho Central Credit Union, 673 North
2nd East, Rexburg, ID
Permit #:
Project Manager: Dan King
Inspector: Parry Thomas
Inspection Date: March 27, 2014
As requested, MTI performed density testing in accordance with current applicable standards. The results
obtained are as follows:
145056 1 Pit Run 127.2 7.5%
Test #
Probe
Depth
(in)
Location
Wet
Density
(pcf)
%
Moisture
Dry
Density
(pcf)
Material #
Required
%
Compaction
%
Compaction Pass/Fail
1 8
Building pad: 3' north, 2' east
of southwest corner of
building, top of pit run (TPR)
128.3 3.6%123.8 1 95%97%PASS
2 8 20' north, 10' east of Test
#1, TPR 126.9 4.0%122.0 1 95%96%PASS
3 8 25' north, 5' west of Test
#2, TPR 129.0 4.1%123.9 1 95%97%PASS
4 8 15' north, 15' east of Test
#3, TPR 127.6 5.6%120.8 1 95%95%PASS
5 8 20' south, 7' east of Test #4,
TPR 129.2 4.8%123.2 1 95%97%PASS
6 8 35' south of Test #5, TPR 129.7 5.6%122.8 1 95%97%PASS
7 8
15' west, 5' north of
southeast corner of building,
-6" TPR
129.9 4.4%124.4 1 95%98%PASS
8 8 40' north, 5' west of Test
#7, -6" TPR 131.3 4.9%125.2 1 95%98%PASS
9 8
25' north, 3' west of
southeast corner of building,
-1' TPR
129.2 4.3%123.8 1 95%97%PASS
Lab ID
#
Material
#Material Description Material Source
Maximum
Density
(pcf)
Optimum
Moisture Standard Used
Zollinger Pit Onsite Stockpile ASTM D-1557
Method of Testing: BS is Backscatter; Depth in inches is Direct Transmission
Gauge Information:
MTI #:40 Make & Model:Troxler 3430 Serial #:23414 Standard Counts:DS:1813 MS:627
ASTM D-6938
Density of Soil and Soil-Aggregate in Place by
Nuclear Methods (Shallow Depth)
PAGE #2 OF 2
REPORT DATE 3/28/2014
R:\Eastern Idaho\2014
Reports\E140030c - Idaho Central
Credit Union, 673 North 2nd East,
Rexburg, ID\rpt007md.docx
Environmental Services Geotechnical Engineering Construction Materials Testing Special Inspections
1230 N Skyline Drive, Suite C Idaho Falls, ID 83402 (208) 529-8242 Fax (208) 529-6911
www.mti-id.com mti@mti-id.com Rev. January 21, 2014
M AT E RI ALS
TESTI NG &
INSPECT ION
If there are questions concerning this report (rpt007md.docx), please contact the project manager at (208) 529-8242.
Respectfully submitted,
MATERIALS TESTING & INSPECTION, INC.
Reviewed by: Monica Saculles, P.E.
Geotechnical Engineer
cc: