HomeMy WebLinkAboutINSPECTION REPORT ELECTRICAL 2 - 14-00050 - Idaho Central Credit UnionCommunity Development Department Phone (208)359-3020 Inspection Hotline: (208)372-2344 INSPECTION REPORT Inspection Type Building Type Inspection ELECTRICAL BLD-COM ELE-FINAL Permit Number: Address: 673 North 2nd East Project: 14-00050 Idaho Central Credit Union Inspection Date 8/7/2014 Inspection Result: PASS D ESCRIPTIO N CO MMEN TS STATUS Receptacles have correct polarity, grounding, no open neutrals, etc. 200.10(B) COMPLETED Identify installations and equipment requiring special approval or investigation. 90.4, 90.7, 110.2, 110.3 COMPLETED Verify that interrupting ratings are adequate for the conditions of the installation. 110.9 COMPLETED Verify that unused openings have been effectively closed.110.12(A), 408.7 COMPLETED Verify adequate working clearances, dedicated spaces, and headroom around equipment. 110.26(A), (E), and (F) COMPLETED Verify that working spaces have adequate illumination.110.26(D) COMPLETED Check for identification of disconnecting means and circuit directories for panelboards, switchboards, and similar equipment.110.22, 408.4 COMPLETED Check for insulating bushings or grommets where NM cable is installed through metal studs or conductors 4 AWG or larger enter enclosures. 300.4(B)(1) and (F) COMPLETED Check cover, fill, protection, and allowances for ground movement on underground conductors and raceways.300.5 and Table 300.5 COMPLETED Check for continuity and completeness in metal raceways and enclosures. 300.10 COMPLETED Page 1 of 2 Verify that wiring methods are securely fastened in place, supported independently of suspended ceilings, and not used as supports.300.11 and applicable Chapter 3 article(s) APPROVED Verify that raceway systems are complete prior to installation of conductors. 300.18(A) COMPLETED Verify that raceways and cables are secured to boxes.314.17(B) and (C) COMPLETED Check for closure of unused openings.314.17(A) COMPLETED Check for excessive gaps between edges of boxes and plaster, plasterboard, or drywall surfaces.314.21 COMPLETED Check for covers on boxes.314.25, 314.28(C) COMPLETED Verify that switches are located not over 6 ft 7 in. (2 m) high and that they can be operated from readily accessible places unless otherwise permitted.404.8(A), 240.24(A) COMPLETED Check receptacles for proper polarity and for grounding and bonding connections. 406.3, 250.146, 200.11 COMPLETED Verify that receptacle ratings and branch-circuit ratings are compatible. 210.21, 210.24 COMPLETED Approved for a final and Temporary C.O. in noted areas. For preliminary final electrical inspection-need to change breaker for A/C unit to listed size and bond to water line in main panel room. COMPLETED Inspector: Bret Stoddard Page 2 of 2