HomeMy WebLinkAboutINSPECTION REPORT - 13-00107 - 565 Terra Vista Dr - SFRCommunity Development Department
Phone (208)359-3020
Inspection Hotline: (208)372-2344
INSPECTION
REPORT
Inspection Type Building Type Inspection
ELECTRICAL BLD-SFR ELEFINAL-R
Permit Number:
Address: 565 TERRA VISTA DR
Project:
13-00107 565 Terra Vista Dr. - SFR
Inspection Date
9/3/2014
Inspection Result: PASS
D ESCRIPTIO N CO MMEN TS STATUS
Gaps around boxes in walls. 314.21 COMPLETED
Polarity of devices and luminaires.
200.10(B), 200.11, 410.23, 406.9
COMPLETED
Unused openings in boxes and other
enclosures are closed. 110.12, 314.17(A),
312.5(A)
COMPLETED
Disconnecting means on both permanently
connected and cord- and plug-connected
appliances. Article 422 Part III
COMPLETED
Circuits for mechanical equipment have
correct conductor size and overcurrent
protection. Articles 422, 424, 430, and 440
COMPLETED
Spacing of receptacles for walls and
countertops, including islands and
peninsulas. 210.52(A) and (C)
COMPLETED
Countertop receptacles are provided with
GFCI protection. 210.8(A)(6)
COMPLETED
Properly sized circuits are provided for
specific kitchen appliances, such as
dishwashers, disposals, ranges, cooktops,
trash compactors, and the like. 210.23,
422.10
COMPLETED
Bathroom receptacles are GFCI protected.
210.8(A)(1)
COMPLETED
Arc-fault circuit-interrupter (AFCI)
protection on bedroom circuits. 210.12
COMPLETED
Clearances between luminaires and
storage spaces if luminaires are installed.
410.8
COMPLETED
Proper receptacle ratings based on
branch-circuit ratings, including
receptacles for electric dryers. 210.21,
210.24, 250.140
COMPLETED
Page 1 of 2
GFCI protection at laundry sink locations
within 6’. 210.8(A)(7)
COMPLETED
Wall-switch-controlled lighting outlet or a
lighting outlet containing a switch is
provided at the entrance to equipment
requiring servicing. 210.70(A)(3)
COMPLETED
Outdoor receptacles are GFCI protected
unless they are not readily accessible and
are supplied by circuits for deicing or
snow-melting equipment(GFPE required
otherwise with a disconnecting
means-breaker lock). 210.8(A)(3), 426.28,
426.50(A)
COMPLETED
Proper identification of all overcurrent
devices and disconnects. 110.22,
230.70(B), 408.4
COMPLETED
Open spaces in panelboard fronts. 110.12 COMPLETED
Approved for a final and C.O.Range hood needs to be mounted back
on wall-Ted will verify.
COMPLETED
Inspector: Bret Stoddard
Page 2 of 2