HomeMy WebLinkAboutINSPECTION REPORT ELECTRICAL - 14-00309 - 450 S 4th E - Bathroom RemodelCommunity Development Department
Phone (208)359-3020
Inspection Hotline: (208)372-2344
INSPECTION
REPORT
Inspection Type Building Type Inspection
ELECTRICAL BLD-SFRR ELEROUGH-R
Permit Number:
Address: 450 South 4th East
Project:
14-00309 450 S. 4th E. - Bathroom Remodel
Inspection Date
9/24/2014
Inspection Result: PASS
D ESCRIPTIO N CO MMEN TS STATUS
Boxes-conductor fill. 314.16 COMPLETED
Cable installation through or parallel to
framing members for 1¼-in. clearance or
provide suitable protection, nail plates, etc.
300.4
COMPLETED
Boxes are installed in accessible locations
for all junctions and outlets and pull points.
300.15, 314.29
COMPLETED
Boxes used in floors, or for support of
ceiling fans, for listing. 314.27(C)(D)
COMPLETED
Bathrooms-receptacle outlets are installed
adjacent to and within 36 in. of each basin.
210.52(D)
COMPLETED
Clearances between luminaires and
storage spaces if luminaires are installed.
410.8
COMPLETED
Approved for cover in noted areas.In the master bathroom remodel,
bedroom recessed cans and closet lights,
and smoke alarms installed in all
bedrooms.
COMPLETED
Inspector: Bret Stoddard