HomeMy WebLinkAboutREVIEW REPORT 1 - 16-00479 - 269 S 5th W - Campus Courtyard 2 Bldg 5 - 21 UnitsReview
Report
Current Building Review Status: APPROVED
Application Number: 16-00479Permit Details
Application Received Date: 07/08/2016
Multi-Family Residential
Application Approved Date:
Application Approved Status: APPROVED
07/11/2016
273 S 5th W
Campus Courtyard 2 Bldg 5 (21 Units)
Status of Plan Reviews Completed
07/11/2016REVISIONSElectrical Review
07/19/2016APPROVEDElectrical Review
08/16/2016REVISIONSBuilding Review
08/17/2016APPROVEDPlumbing Review
08/17/2016APPROVEDHVAC Review
11/14/2016APPROVEDBuilding Review
Permit Review Status
Plan Reviews Still in Progress
DESCRIPTION COMMENTS STA TUS
*Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed!
Penetrations meet the requirements of IBC
Section 713
No details shown. Final approval to be
determined at inspection.
COMPLETED
Ducts and dampers meet the requirements of IBC
Section 716
No mechanical plans submitted. Rated ceiling
penetrations may require a fire damper in line
with ceiling.
COMPLETED
fireblocking and draftstopping meet the
requirements of IBC Section 717.
Insufficient details will be approved based on
inspection.
Draftstopping in attic shall divide attic into areas
no larger than two units.
COMPLETED
An Energy Review is provided Submit hard copy or electronic copy.COMPLETED
Special Inspections are required as per IBC
Chapter 17
Special inspections as required for masonry and
structural steel.
COMPLETED
Reviewed By: Quinton Owens
Review Date: 11/14/2016