HomeMy WebLinkAboutFIRE SPRINKLER PRODUCT INFO - 16-00573 - 486 S 3rd W - The Roost - Bldg #2 - MFRQFC P.O. Box 3365 South EI Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 510 CPVC - COPPER - STEEL HANGER SIZE - SYSTEM PIPE: 3/4" thru 3" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - '@#1203 - EX 4231, EX 2551 FUNCTION - Support horizontal piping: 3/4" -3" CPVC. Support horizontal piping: 3/4"-2" Steel and Copper. Size 3/4" - 2" provides listed vertical/lateral restraint and prevents upward movement of pipe that supplies a pendent sprinkler below a ceiling. Stabilize vertical piping. INSTALLATION - Per these Instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. FASTENERS - UL Listed per NFPA 13 in WOOD: 3/4" - 3" CPVC pipe - #905 screw - no pre -drill. 3/4" - 2" Steel and Copper pipe - 1/4"xl1/2" lag bolt - no pre -drill. in STEEL - min. 18 GA. 3/4" - 3" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Steel and Copper pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. w Retainer dimples secure hanger to pipe during installation. * Required AFCON #905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. CAN ALSO BE USED TO REPLACE - #500 Pipe Strap #520 Tin Strap SpeciFlc AFCO.Ypmducts are exclusively designed m be compatible ONLY with wherAFCONpooducts including pans and fasteners, resulting in a listed sway braes, restrainer or hanger assembly. Be advised the following wafmnI, astriction will apply. DISCLMNMR. AFCONwill NOT warrant against the failure of its products when used in combination with other products, pans or ayatoms not manufectomd or said by AFCON.. AFCONshall NOT he liable under any circumstances whatsoever for any do c t or ind met, incidental or consequential damages ofany kind, including but not limited to loss ofbusiness or joaR when non-AFCONproducts have been, or am used. 1/12 '�'Eg Dg P.O. Box 3365 South EI Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 514 CPVC - COPPER •STEEL OFFSET HANGER SIZE - SYSTEM PIPE: 3/4" thru 3" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized.. LISTING/APPROVAL- 0@0 - EX 4231, EX 2551 PATENT - No. 6,648,278. FUNCTION - Support horizontal piping: 3/4" -3" CPVC or Copper. • Support horizontal piping: 3/4" - 2" Steel. Size 3/4" - 2" provides listed vertical/lateral restraint and prevents upward movement of pipe that supplies a pendent sprinkler below a ceiling. Stabilize vertical piping. INSTALLATION- Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Listed Install on horizontal or vertical mounting surface. 3/4" Snap over pipe then squeeze strap back allowing pipe to slide freely. a When #905 threads are exposed in wood, install #906 backing nut. FASTENERS - UL Listed per NFPA 13 WOOD - 3/4" - 3" CPVC pipe - #905 screw- no pre -drill. 3/4" - 2" Copper pipe - #905 screw- no pre -drill. 3/4" - 2" Steel pipe - 1/4"xl 1/2" lag screw - no pre -drill, Thru 5/8" gypsum board - 1/4" x 2" lag screw. STEEL - min. 18 GA. - 3/4" - 3" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Copper pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Steel pipe - 1/4" or #14 Tek Screw. CONCRETE: Required minimum load each fastener= 5(wt)+250lbs. 2 FEATURES * 1 1/2" Offset - loose fit allows pipe to slide. * 3/4" and 1" pipe size made with common center -line. * Patented design for superior strength. * Offset edge eliminates abrasion. * AFCON #905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. AFCON #906 backing mut sold separately. 906 0 4 f 4 0 v a P Listed Restraint elnt 34"tN 2" SpecificAFCONproducts are exclusively designed to be compatible ONLY with otherAFCONpraducta including pans and fasteners, resulting in a listed sway brace, restrainer or hangerassembly Be advieed the following warranty restriction will apply. DISCLAIMER- AFCONwill NOT warrant against the failure ofits products when used m combination with other products, parts or systems solmanufaclumdorsoldbyAFCON. AFCONlull NOT be liable order any eimurestanceswtem.erInner, direct or induceq incidental or consequential damages ofarty kind, including but not limited to loss ofbusincss orpro@, whrn non-AFCONproducts M1ave been, or etc used. 10/08 F7 �F P.O. Box 3365 South EI Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 511 CPVC - COPPER SIDE MOUNT HANGER SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - `®a 203 - EX 4231, EX 2551 FUNCTION - Support horizontal piping - CPVC or Copper. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on vertical mounting surface. FASTENERS - UL Listed per NFPA 13. in WOOD: 3/4" - 2" CPVC pipe - #905 screw - no pre -drill. 3/4" - 2" Copper pipe - #905 screw - no pre -drill. in STEEL - min. 18 GA. 3/4" - 2" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Copper pipe - 1/4" or #14 Tek Screw. FEATURES " Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCON#905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. Side View - For Drawings Below Hanger - Wood Stud Hanger - Metal Stud Specific AFCONproduces are exclusively deigned to be compatible ONLY with otherAFCONpmducts including parts and fasteners, resulting in a listed sway bmee, restrainer or hanger assembly. B ads%ed the following wusmtty restriction will apply. EHSCLALNER- AFCONwill NOT warrant agamst the failure of its produces when used in combination with other pnidimts, parts m systems not manufactured or sold by,dFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indvaL incidental or conscquenlial damages of any kind, including but not limited to loss of business cur pmfit, when non,AFCONproducts have been, or am used. Rro 9/08 Series 2000B Sizes: '/2" — 2" (15 — 50mm) Features • Ease of maintenance with only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design • '/2" - 2" (15 - 50mm) Cast bronze body construction • Top mounted ball valve test cocks • Low pressure drop • No special tools required • Y2" - 1 " (15 - 25 mm) have tee handles Available Models Suffix: B - Quarter turn ball valves LBV - less ball valves SH - stainless steel ball valve handles HC- 2'/Z" inlet/outlet fire hydrant fitting (2" valve) Pressure — Temperature Temperature Range: 33°F -140°F (0.5"C - 60"C) Maximum Working Pressure: 175psi (12.1 bar) Standards AWWA Std. C510, IAPMO PS31 It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material prod- uct, consult your local water authority, building and plumbing codes. ES -A -2000B A A M E FIRE & WATER WOF t 2" 2000B HC JL (50mm) W 2000B (20mm) Series 2000B Double Check Valve Assemblies are designed to protect drinking water sup- plies for dangerous cross -connections in accordance with national plumbing codes and water authority requirements for non -health -hazard non -potable service applications such as irrigation, fire line, or industrial processing. These valves meet the requirements of ASSE Std. 1015 and AW WA Std. C510 and are approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Specifications A Double Check Valve Assembly shall be installed at each noted location. The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated Isolation valves and four top mounted, resilient seated test cocks. The assembly shall meet the requirements of ASSE Std. 1015 and AW WA Std. C510. Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be an Ames Company Series 2000B. Approvals �`�asrvy� NOC@us %-1-2-1 (LBV Models Only) Q ,SA® us 1015 1154.5 Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. LBV models not listed. Horizontal and vertical "flow up" approval on all sizes. Jab Name Job Location Engineer Approval Contractor Approval Contractor's P.O. No. Representative_ Anes product specifications in U.S. customary ants and mehic are approximate and are provided for reference a*. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specblcatians, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. amesfirewater.com Dimensions - Weights Suffix HC - Fire Hydrant Fittings dimension "A" = 231h" (594mm) Capacities As compiled from documented Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California lab tests. ATypical maximum system flow rate (7.5 feettsec., 2.3 meters/see.) kPa pal 1/ze (15mm) 83 12 69 10 "t55 8 LD 41 6 28 4 14 2 IL 0 0 0 2 4 6 8 10 12 fpm 5P 0 7.6 15.2 22.8 30.4 38 45.61pm 5 7.5 10 fps 1.5 2.3 3.0 mps Flow Rate kPa psi 3/4° (20mm) v, 152 22 124 18 d 96 14 h 69 10 a 41 6 14 2 kPa psi 96 14 a 83 12 J 69 10 y 55 8 j 41 6 28 4 14 2 a 0 0 411.11 WE ■�������� 4P 0 10 20 30 40 50 60 70 80 90 100 110 120 qpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 83 12 W 69 10 10 55 8 41 6 28 4 14 2 a o 0 5p0 0 AP 0 5 10 15 26 25 30 35 40 45 50 ppm 200gpm 95 190 285 0 19 39 U 76 95 114 133 14 171 190 line 7.5 10 15 fps 7.5 15 fps mps 2.3 4.6 mps kPa psi Flow Rate y 63 12 iio sl a 111(25mm) "o ss 10 1Pa m -I 55 8 41 6 y 9 10 65 a 28 4 y 41 6 14 2 m 28 4 4 0 0 d 14 2 0 5P 0 5P 0 19 38 57 75 95 114 133 15: 5 7.0 10 15 ib 2.34.6 Flow Rate A M E S FIRE& WATERWORKS A Watts Water Technologies Company ES -A-20006 1410 50 55 609pm 190 209 228 1pm fps mps 10 20 30 40 50 60 70 80 90 100 110 120 Spm 38 76 114 152 190 228 286 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate 2" (50mm) 25 50 75 100 125 150 175 200gpm 95 190 285 350 475 570 665 760 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate USA: Backflow Tel: (978) 889-5066 • Fax: (978) 975-8350 • AmesRreWater.com USA: Control Valves Tel: (713) 943-0588 • Fax; (713) 944-9445 • AmesFireWater.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • AmesRreWater.ca Latin America; Tel: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • AmesFreWater.com 0 2014 Ames Fire & Waterworks Series 4000B Pressure Zone Sizes: Ik" - 2" (15 - 50mm) Features • Single access cover and modular check construction for ease of maintenance • Top entry - all internals immediately accessible • Captured springs for safe maintenance • Internal relief valve for reduced installation clearances • Replaceable seats for economical repair • Bronze body construction for durability - t/2" to 2" (15-50mm) • Ball valve test cocks - screwdriver slotted -1/2" to 2" (15-50mm) • Large body passages provides low pressure drop • Compact, space saving design • No special tools required for servicing The information contained herein is not intended to replace the full product instal- lation and safety information available or the experience of a trained product install- er. You are required to thoroughly read all installation instructions and product safety information before beginning the installa- tion of this product. ES -A -4000B 2" (50mm) 4000B -HC Series 4000B Reduced Pressure Zone Assemblies are designed to protect drinking water supplies from dangerous cross -connections in accordance with national plumbing codes and water authority requirements for health - hazard non -potable service applications such as irrigation, fire line, or indus- trial processing. This series features two in-line, independent check valves, captured springs and replaceable check seats with an intermediate relief valve. Its compact modular design facilitates easy maintenance and assembly access. Sizes 1/2"- 1 " (15-25mm) shutoffs have tee handles. Specifications A Reduced Pressure Zone Assembly shall be installed at each potential health hazard location to prevent backflow due to backsiphonage and/or backpressure. The assembly shall consist of an internal pressure differential relief valve located in a zone between two positive seating check modules with captured springs and silicone seat discs. Seats and seat discs shall be replaceable in both check modules and the relief valve. There shall be no threads or screws in the waterway exposed to line fluids. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated iso- lation valves, four resilient seated test cocks and an air gap drain fitting. The assembly shall meet the requirements of: USC Manual 8th Editiont; ASSE Std. 1013; AWWA Std. C511; CSA B64.4. The assembly shall be an Ames Company Series 4000B. soIIt,LDIW.1R*1111 OW 9 ' 1]g�►`1►��1'h Job Location 7775 N GRANITE RIDGE RD Approval Engineer Contractor's P.O. No. Approval Representative_ Ames product specifications in U.S. customary units and metric are approumate and are prodded for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials wilho rt prior notice and without incurring any obligation to make such changes and mod cations on Ames products previously or subsequently sold. amesfirewater.com Materials Bronze body construction, silicone rubber disc material in the first and second check plus the relief valve. Replaceable poly- mer check seats for first and second checks. Removable stain- less steel relief valve seat. Stainless steel cover bolts. Standardly furnished with NPT body connections. For optional bronze union inlet and outlet connections, specify prefix U (1/z" - 2")(15-50mm). Series 40008 furnished with quarter tum, full port, resilient seated, bronze ball valve shutoffs. Standards AWWA C511-92, USC Manual 8th Edition, IAPMO File No. 1563 Approvals �� 8556 ®R U " o Cc S)BL US 1013 864.4 B/4" - 2" (20.50mm) (LBV models only) Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Approval models CIT, U. Weights — Dimensions Nam Pressure — Temperature Suitable for supply pressures up to 175psi (12.06 bar) and water temperature to 180"F VVC) continuous. Available Models Suffix: B - quarter -turn ball valves LBV - less ball valves SH - stainless steel ball valve handles HC - 21h° inlettoutlet fire hydrant fitting (2" valve) S - bronze strainer Prefix: In. U - union connections Inquire with governing authorities for local installation requirements I It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before Installing standard material product, consult your local water authority, building and plumbing codes. L E M 0 I of A MODEL SIZE (DN) Suffix HC - Fire Hydrant Fittings dimension "A11 DIMENSIONS = 251/16 STRAINER (637mm) DIMENSIONS WEIGHT M. mm In. A mm In. B mm 0 In. mm M. D mm L In. mm M In. mm N /ft. mm W. k9.. 400013" 'h 15 10 250 4% 117 3% 86 1'/e 32 5'fe 140 3 76 2 51 4.50 2.0 4000B M3" V44 20 101/1 273 5 127 3'h 89 1'h 38 6e/4 171 Vie 84 25% 59 5.75 2.6 40006 M2" 1 25 141h 368 5'h 140 3 76 2'h 64 9'h 241 444 114 2%B 59 12.25 5.6 40008" 11% 40117r7A 454 1 6 150 1 31h 89 1 2'h 64 1 11'% 283 1 51h 149 1 3e/4 95 1 16.32 7.4 41h 124 1 30.00 13.6 "Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. 6 Capacity Performance as established by an Independent testing laboratory. ATypical maximum system flow rate (7.5 feettsec., 2.3 meters/sec.) kPa psi 1/4" (8mm) kPa psi 138 20 m 207 30 J 117 17 J 172 25 12 96 14 138 20 y 76 1155 8 N 103 15 1 35 5 d 69 10 AP 0 .25 .50 .75 1 1.17 gpm 34 5 0 95 19 29 38 451pm 0 0 Flow Rate AP 0 kPa psi W, (10mm) We psi y 138 20 y 172 25 9 117 17 .oi 138 20 ` 96 14 103 15 76 11 w ED 55 8 12 69 10 C 35 5 a 34 5 AP 0 .25 .50 .75 1 1.25 1.50 2.5 3.1 gpm 0 0 0 .95 1.9 2.9 3.8 4.8 5.7 9.5 11.8 Ipm AP 0 Flow Rate 0 kPa psi H 172 25 J 138 20 2 103 15 69 10 IL 35 5 AP 0 kPa psi 207 30 1165 24 3124 18 83 12 LD 41 6 CL 0 0 1/2" (15mm) 1 2.5 5 7.5 10 3.8 9.5 19 28.5 38 5 7.5 1.52.3 Flow Rate W (20mm) 1" (25mm) 5 10 20 30 40 50 19 38 76 114 152 190 7.5 15 2.3 4.6 Flow Rate 1114" (32mm) bu 7u Su gpm 228 266 304 Ipm fps mps 10 20 30 40 50 60 70 80 gpm 38 76 114 152 190 228 266 304 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate 2 69 ' 7•. PSI 207 30 MMMMIMMM...0 172 25� EMENIMMEME■� .. i 103 15 2 69 ' ' ME.ENIMEMMEMM 12.5 15 gpm o 0 47.5 57 Ipm Ap 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 15 fps 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 4.6 mps 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 207 30 172 25 S 138 20 103 15 69 10 34 5 o. 0 2 6 10 14 18 22 2630 34 38 42 46 pm 0 APO AP 0 7.6 23 38 53 68 84 99 114 129 144 160175 Ipm O 7.5 15 fps 2.3 4.6 mps Flow Rate 2" (50mm) 20 40 60 80 100 120 140 160 180 200 gpm 76 152 228 304 380 456 532 608 684 760 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate 3 A A M E S A Watts Water Technologies Company USA: Backflow Tel: (978) 689-6088 • Fax: (978) 975-8350 • AmeaFlreWater.com USA: Control Valves Tel: (773) 943-0688 • Fax: (713) 944-9445 • AmesFlreWater.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • AmesFlreWater.ca Latin America: Tel: (52) 81-1001-8609 • Fax: (52) 81-8090-7091 • AmesRreWater.com ES -A-40006 1410 0 2014 Ames Fre & Waterworks t igCQ Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 BlazeMaster° CPVC Fire Sprinkler Pipe Addendum #1 to IH -1900, General Description Addendum #1 revises the content of the Factory Mutual approval under the "Listings and Approvals" section of the TFP BlazeMaster Installation & Tech- nical Handbook IH -1900 dated Janu- ary 2005. The revision now permits the use of "Exposed Installation" and "System Risers" in addition to "Con- cealed Installation". Addendum #1 Factory Mutual (FM) TFP BlazeMaster CPVC pipe and fit- tings are FM Approved for use in: • Miscellaneous nonmanufactur- ing occupancies as described FM Loss Prevention Data Sheet 3-26, "Fire Protection Water Demand for Nonstorage Sprinklered Prop- erties", Table 2, Section L. • Residential occupancies as de- scribed in FM Loss Prevention Data Sheet 2-8N, "Installation of Sprinkler Systems". TFP BlazeMaster Fire Sprinkler Sys- tems shall be employed in wet pipe systems only. (A wet pipe system con- tains water or water and glycerin (anti- freeze solution) and is connected to a water supply so that the water or water and glycerin (anti -freeze solution) will discharge immediately when the sprin- kler is opened. Concealed Installations In accordance with the FM Approval, protection shall be provided for TFP BlazeMaster CPVC pipe and fittings as follows: • The minimum protection shall con- sist of either a permanently In- stalled non-combustible barrier from any area protected by the system. & Fittings January, 2005 NOTE A permanently installed barrier is one that cannot be removed with- out substantial cosmetic dam- age. Drop in ceiling tiles, as used in suspended ceilings are specifi- cally considered not be perma- nently installed for the purposes of this definition. Non-combustible is defined as having a minimum fin- ish fire rating of 15 minutes when tested per ASTM El 19. • As an alternative to the protection of a permanently installed non- combustible barrier FM has ap- proved the use of TFP BlazeMas- ter CPVC with the Soffi-SteelTM covering system manufactured by Grice Engineering. • FM Approved quick response, standard or extended coverage, or FM Approved residential sprin- klers installed in accordance with their approval limitations may be used. • Solvent cement joints shall be made with TFP-400 or TFP-500 One Step Solvent Cement. Exposed Installations In accordance with the FM Approval, TFP Blazemaster pipe and fittings may be installed without protection (ex- posed), subject to the following addi- tional limitations: NOTES Where piping is installed above drop in ceiling tiles, the piping shall be consid- ered exposed. Ceilings may be combustible, or non permanently installed. Smooth, flat, horizontal, ceilings • Standard Coverage Sprinklers Pendent sprinklers shall be FM Ap- proved, quick response sprinklers having deflectors installed within 8" from the ceiling. The maximum distance between sprinklers shall not exceed 15'. The maximum ceiling height shall not exceed 10'. - Upright sprinklers shall be FM Ap- proved, quick response sprinklers having deflectors installed within 4" from the ceiling. The maximum distance between sprinklers shall not exceed 15'. The maximum dis- tance from the ceiling to the cen- terline of the main run of pipe shall not exceed 7-1/2". The distance from the centerline of the sprinkler head to the closest hanger shall be 3". The maximum ceiling height shall not exceed 10'. - Horizontal Sidewall Sprinklers shall be FM Approved, quick re- sponse sprinklers having deflec- tors installed within 12" from the ceiling and within 6" from the side- wall. The maximum distance be- tween sprinklers shall not exceed 14'. The maximum ceiling height shall not exceed 10'. - Solvent cement joints shall be made with TFP-400 or TFP-500 One Step Solvent Cement. • Extended Coverage Sprinklers Pendent sprinklers shall be FM Ap- proved, quick response sprinklers having deflectors installed within 8" from the ceiling. The maximum distance between sprinklers shall not exceed 20'. When the sprin- klers are not on square spacings, the flow for that sprinkler should be based on the density applied Page t of 2 October, 2005 #1/IH-1900 Page 2 of 2 #1/IH-1900 over the square area calculated for the largest dimension of the sprin- kler spacing. The maximum ceiling height shall not exceed 10'. - Horizontal Sidewall Sprinklers shall be FM Approved, quick response sprinklers having deflectors in- stalled within 12" from the ceiling and within 6" from the sidewall. The maximum lateral distance be- tween sprinklers shall not exceed 16'. The maximum ceiling height shall not exceed 10'. - The minimum flow or pressure es- tablished for Extended Coverage Systems shall be per FM Loss Pre- vention Data Sheet 2-8N and 3-26. Solvent cement joints shall be made with TFP-400 or TFP-500 One Step Solvent Cement. • Residential Sprinklers - Pendent sprinklers shall be FM Approved, residential sprinklers having deflectors Installed within 8" from the ceiling. The maximum distance between sprinklers shall not exceed 20'. The minimum re- quired discharge from each sprin- kler is to be the greater of either the approved flow rate applied over the square area calculated for the largest dimension of the sprinkler spacing or a minimum discharge of 0.1 gpm/sq.ft. over the actual area (SxL) covered by the sprin- kler. The maximum ceiling height shall not exceed 10'. - Horizontal Sidewall Sprinklers shall be FM Approved, quick response sprinklers having deflectors in- stalled within 12" from the ceiling and within 6" from the sidewall. The maximum lateral distance be- tween sprinklers shall not exceed 16'. The minimum required dis- charge from each sprinkler is to be the greater of either the approved flow rate applied over the area cal- culated for the largest dimension of the sprinkler spacing or a min- imum discharge of 0.1 gpm/sq.ft. over the actual area (SxL) covered by the sprinkler. The maximum ceiling height shall not exceed 10'. - The minimum flow or pressure es- tablished for Residential Sprinkler Systems shall be per FM Loss Pre- vention Data Sheet 2-8N and 3-26. - Solvent cement joints shall be made with TFP-400 or TFP-500 One Step Solvent Cement. System Risers In accordance with the FM Approval, TFP BlazeMaster pipe and fittings may be installed without protection (ex- posed) as a vertical riser when subject to the following additional limitations: • An automatic sprinkler (of the same type as in the area being protected) shall be located adja- cent to and no further than 1 ft (0.3 m) from the riser. • The automatic sprinkler protecting the riser shall not be considered when determining protection crite- ria for the floor area. The design flow for the sprinkler protecting the riser must be the same as for the other sprinklers; and must be add- ed to the hydraulic calculation. • Solvent cement joints shall be made with TFP-400 or TFP-500 One Step Solvent Cement. BlazeMaster® is a registered trademark of Noveon IP Holdings Corp. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446 FIRE SPRINKLER CORPORATION DESCRIPTION AND OPERATION RESIDENTIAL AUTOMATIC SPRINKLERS MODEL GL4431 HORIZONTAL SIDEWALL RECESSED HORIZONTAL SIDEWALL The Globe Model GL4431 Residential Horizontal Sidewall Sprinklers have a durable design which utilizes a 3mm fran- gible glass ampule as the thermosensitive element. They feature economy, aesthetics and lowflow. The combination of the 3mm frangible glass ampule and specially designed deflectormake the Model GL4431 Sprin- klers the ultimate in life safety and fire control. These Globe Horizontal Sidewall and Recessed Horizontal Sidewall Residential Sprinklers have met the strict requirements of Underwriters Laboratories Inc. as described in the UL Standard for Residential Sprinklers for Fire Protection Ser- vice, UL 1626, and should be used accordingly. These sprinklers should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direction of the approving authorities having jurisdiction. The heart of Globe's Model GL4431 sprinklers proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed tem- perature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an ap- proved pattern. TECHNICAL DATA •See reverse side for Approvals and Specifications. *Temperature Rating - 155'F (68°C), 175'F (79°C). • Water Working Pressure Rating - 175 psi (12 Bars). • Factory tested hydrostatically to 500 psi (34 Bars). *Maximum low temperature glass bulb rating is -67°F (-550C). • Frame - bronze • Deflector - brass • Screw - brass *Bulb seat - copper • Spring - nickel alloy • Seal - teflon • Bulb - glass with alcohol based solution, 3mm size. • Escutcheon Assembly - steel r RESIDENTIAL HORIZONTAL SIDEWALL RESIDENTIAL RECESSED HORIZONTAL SIDEWALL • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER N.F.P.A. MAXIMUM CLASSIFICATION TEMPERATURES BULB COLOR CEILING TEMPERATURE WS nj�P^MZl ORDINARY -MW RED Y;II Ilk - YELLOW b�+INTERMEDIATE 4077 AI RPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX989-846-9231 SEPTEMBER2011 A-5 BULLETIN GL4431, REV. # RESIDENTIAL AUTOMATIC SPRINKLERS MODEL GL4431 HORIZONTAL SIDEWALL & RECESSED HORIZONTAL SIDEWALL SPECIFICATIONS AND APPROVALS SIN MODEL K FACTOR THREAD SIZE LENGTH FINISHES 155°F 680C 175°F 790C cULus 14'x 14' 15 GP.M. -11.6 P.S.I. GL4431 16'x 16' Factory Bronze 16'x 18' 19 GP.M. -18.7 P.S.I. GL4431 4.4 (62 metric) 1/2" NPT 2 1/2" (6.4 cm) Chrome X X X White Polyester Black Polyester' 'AVAILABLE AS cULus LISTED CORROSION RESISTANT - POLYESTER MUST BE SPECIFIED ON ORDER. INSTALLATION DATA FOR FLAT AND SLOPED CEILINGS" HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SIN MODEL MAXIMUM AREA OF COVERAGE MINIMUM WATER DISCHARGE & PRESSURES NEEDED PER SPRINKLER* 12'x12' 13 GRM. - 8.7 P.S.I. 14'x 14' 15 GP.M. -11.6 P.S.I. GL4431 16'x 16' 16 GP.M. -13.2 P.S.I. 16'x 18' 19 GP.M. -18.7 P.S.I. 16' x 20' 23 GRM. - 27.3 P.S.I. DEFLECTOR DISTANCE 4" TO 6" DOWN FROM CEILING. *WHEN THESE SPRINKLERS ARE USED IN NFPA 13 SYSTEMS, A 0.1 DESIGN DENSITY MINIMUM SHALL BE UTILIZED. **REFER TO PAGE 2 OF THE GLOBE RESIDENTIAL SPRINKLER INSTALLATION GUIDE FOR NFPA 13D and 13R REQUIREMENTS. CROSS SECTION 1/2" OR 3/4" ADJUSTMENT RECESSED HORIZONTAL SIDEWALL GLNO, FA "S FIRE SPRINKLER CORPORATION SEPTEMBER 2011 ORDERING INFORMATION SPECIFY • Quantity • Model Number • Style • Orifice • Temperature • Finishes desired • Quantity - Wrenches - P/N 325390 • Quantity - Recessed Wrenches - P/N 327102 • Quantity - Protective Caps - P/N 327109 -CAP (Friction Fit Recessed) GLOBE' PRODUCT WARRANTY Globe agrees to repair or replace any of Its own manufactured products found to be defective in mate- rial or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 1-800-248-0278 PRINTEDU.S.A. FAX989-846-9231 www.globespOnkler.com BULLETIN GL4431, REV. # FIRE CORPORATION DESCRIPTION AND OPERATION RESIDENTIAL AUTOMATIC SPRINKLERS MODELS GL4110 & GL4910 PENDENT RECESSED PENDENT The Globe Model GL4110 and GL4910 Residential Sprinklers have a low profile yet durable design which utilize a 3mm fran- gible glass ampule as the thermosensitive element. They feature economy, aesthetics and low flow. The combination of the 3mm frangible glass ampule and spe- cially designed deflector make the Model GL4110 and GL4910 Residential Sprinklers the ultimate in life safety and fire control. These Globe Pendent and Recessed Pendent Residential Sprin- klers have met the strict requirements of Underwriters Laboratories Inc. as described in the UL Standard for Residential Sprinklers for Fire Protection Service, UL 1626, and should be used accordingly. These sprinklers should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direc- tion of the approving authorities having jurisdiction. The heart of Globe's Model GL4110 and GL4910 sprinklers proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pres- sure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern. The sprinkler and escutcheon are not factory assembled. Assembly is done in the field. TECHNICAL DATA •See reverse side for Approvals and Specifications. •Temperature Rating - 155°F (680C), 175°F (79°C) *Water Working Pressure Rating - 175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) *Maximum low temperature glass bulb rating is -67°F (-55°C) • Frame - bronze • Deflector - brass *Screw- brass •Bulb seat - copper •Spring - nickel alloy • Seal - teflon *Bulb - glass with alcohol based solution, 3mm size • Escutcheon Assembly - steel RESIDENTIAL PENDENT ®, oLose� , PMT I" RESIDENTIAL RECESSED PENDENT • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING MARCH 2015 A-1 BULLETIN GL41101GL4910, REV. #9 RESIDENTIAL AUTOMATIC SPRINKLERS MODEL GL4110 & GL4910 PENDENT• RECESSED PENDENT SPECIFICATIONS AND APPROVALS SIN NOMINAL THREAD LENGTH FINISHES cULus NYC - DOB MODEL "K" FACTOR SIZE MIN. FLOW BETWEEN MEA 101.92-E GL4110 4.1 (58 metric) G.P.M. (Umin.) SPRINKLERS EEMetem) Factory Bronze PENDENT X X 12 (3.7) x 12 (3.7) 7.2 (.50) 11 (42) 1/2"NPT 21/2" Chrome 12 (45) GL4110 GL4910 4.9 (68 metric) (15mm) (6.4cm) White Polyesters X X 14 (53) X X 12 (3.7) x 12 (3.7) Black Polyesterl•s 13 (49) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. INSTALLATION DATA FOR FLAT AND SLOPED CEILINGS" NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'WHEN THESE SPRINKLERS ARE USED IN NFPA 13 SYSTEMS, A0.1 DESIGN DENSITY MINIMUM SHALL BE UTILIZED. "REFER TO PAGE 2 OF GLOBE'S RESIDENTIAL SPRINKLER INSTALLATION GUIDE (BULLETIN R.S.I.G.) FOR NFPA 13D AND 13R REQUIREMENTS. 'FOR COVERAGE AREA DIMENSIONS LESS THAN OR BETWEEN THOSE INDICATED, USE THE MINIMUM REQUIRED FLOW FOR THE NEXT HIGHEST COVERAGE AREA FOR WHICH HYDRAULIC DESIGN CRITERIAARE STATED. CROSS SECTION I- zzsns"Dra I i r 171 129/32' DIA r� P x 1/2' REDUCER MIN, Mk(. 1/2" ADJUSTMENT RECESSED PENDENT GL WE FIRE SPRINKLER CORPORATION MARCH 2015 ORDERING INFORMATION SPECIFY •Quantity • Model Number* Style •Orifice •Temperature. Finishes desired •Quantity - Wrenches - P/N 325390 *Quantity - Recessed Wrenches - P/N 325391 *Quantity - Protective Caps - P/N 327109 -CAP (Friction Fit Recessed) GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). PRINTED U.S.A. 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48656 989-846-4583 FAX 989-846-9231 1.800.248.0278 www.globasprinkler.com BULLETIN GL4110/GL4910, REV. #9 TEMPERATURE MAX. AREAMIN. DISTANCE SIN MODEL STYLE OF COVERAGE' 155°F 175 F MIN. PRESSURE MIN. FLOW BETWEEN (68°C) (79°C) LENGTHxWIDTH Feer M em) P.S.I. (bem) G.P.M. (Umin.) SPRINKLERS EEMetem) PENDENT X X 12 (3.7) x 12 (3.7) 7.2 (.50) 11 (42) X - 14 (4.3) x 14 (4.3) 8.6 (.59) 12 (45) GL4110 RECESSED 8(2.4) PENDENT X X 16 (4.9) x 16 (4.9) 11.1 (.77) 14 (53) X X 12 (3.7) x 12 (3.7) 7.0 (.48) 13 (49) X X 14 (4.3) x 14 (4.3) 8.2 (.57) 14 (53) PENDENT X X 16 (4.9) x 16 (4.9) 8.2 (.57) 14 (53) 131-4910 RECESSED 8(2.4) PENDENT X X 18 (5.5) x 18 (5.5) 12.0 (.83) 17 (64) X X 20(6.1)x20(6.1) 16.7(1.15) 20(76) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'WHEN THESE SPRINKLERS ARE USED IN NFPA 13 SYSTEMS, A0.1 DESIGN DENSITY MINIMUM SHALL BE UTILIZED. "REFER TO PAGE 2 OF GLOBE'S RESIDENTIAL SPRINKLER INSTALLATION GUIDE (BULLETIN R.S.I.G.) FOR NFPA 13D AND 13R REQUIREMENTS. 'FOR COVERAGE AREA DIMENSIONS LESS THAN OR BETWEEN THOSE INDICATED, USE THE MINIMUM REQUIRED FLOW FOR THE NEXT HIGHEST COVERAGE AREA FOR WHICH HYDRAULIC DESIGN CRITERIAARE STATED. CROSS SECTION I- zzsns"Dra I i r 171 129/32' DIA r� P x 1/2' REDUCER MIN, Mk(. 1/2" ADJUSTMENT RECESSED PENDENT GL WE FIRE SPRINKLER CORPORATION MARCH 2015 ORDERING INFORMATION SPECIFY •Quantity • Model Number* Style •Orifice •Temperature. Finishes desired •Quantity - Wrenches - P/N 325390 *Quantity - Recessed Wrenches - P/N 325391 *Quantity - Protective Caps - P/N 327109 -CAP (Friction Fit Recessed) GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). PRINTED U.S.A. 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48656 989-846-4583 FAX 989-846-9231 1.800.248.0278 www.globasprinkler.com BULLETIN GL4110/GL4910, REV. #9