Product Description:
FireLock® products comprise a unique system
specifically designed for fire protection services.
FireLock full -flow elbows and tees feature CAD -
developed, hydrodynamic design, affording a shorter
center -to -end dimension than standard fittings. A
noticeable bulge allows the water to make a smoother
turn to maintain similar flow characteristics as standard
full flow fittings.
FireLock fittings are designed for use exclusively with
Victaulic couplings that have been Listed or Approved
for Fire Protection Services. Use of other couplings or
flange adapters may result in bolt pad interference.
Refer to the appropriate listing agency or approval body
for pressure ratings. Pressure ratings vary by agency.
Job/Owner
System No.
Location
Contractor
Submitted By
Date
10.03
Material Specifications:
Fitting:
Ductile iron conforming to ASTM A-536, grade
65-45-12.
Fitting Coating:
❑ Orange enamel
❑ Red enamel in Europe, Middle East, Africa, and
India
❑ Optional: Hot dipped galvanized
Engineer
Spec Section
Paragraph
Approved
Date
victaulic.com I FireLock® Fittings I Publication 10.03
10.03 1539 Rev M Updated 12/2014 ® 2014 Victaulic Company. All rights reserved.
1 rCtaUI I
victaulic.com I Fire Lock® Fittings I Publication 10.03
Dimensions:
wC to E� C
j ` to E'I
ld p C1oE
1.E .Y/ eje to
E
.s
NO. 001 N0.003 N0. 002 No. 006
10.03 1539 Rev M Updated 1212014 02014 Victaulic Company. All rights reserved.
Victaulic.com 2 X ict:auhcr
No. 001
No. 003
No. 002
No. 006
90° Elbow
45° Elbow
Straight Tee
Cap
Actual
._
Approx.--
.._.._._,
Approx.
Approx.
Approx.
Nominal
Outside
Weight
Weight
Weight
Weight
Size
Diameter
C to E
Each
C to E
Each
C to E
Each
C to E
Each
Inches
Inches
Inches
Lbs.
Inches
Lbs.
Inches
Lbs.
Inches
Lbs.
mm
mm
mm
kq
mm
kg
mm
kg
mm
kg
I Y4
1,660
0.82
0.3
32
42A
-
-
-
-
-
-
21
0.1
1 K
1.900
-
-
-
-
-
-
0.82
0.4
40
48.3
21
0.2
2
2.375
2.75
1.7
2.00
1.8
2.75
2.4
0.88
0.6
50
60.3
70
0.8
51
0.8
70
1.1
22
0.3
2rh
2.875
3.00
3.1
2.25
2.2
3.00
3.6
0.88
1.0
65
73D
76
1.4
1 57
1.0
1 76
1.6
22
0.5
76.1 mm
3.000
3.00
3.30
2.25
2.4
3.00
3.8
-
76.1
76
1.5
57
1.1
76.2
1.7
-
3
3.500
3.38
4.0
2.50
3.1
3.38
5.3
0.88
1.2
80
88.9
86
1.8
64
1.4
86
2.4
22
0.5
108mm
4.250
4.00
5.7
3.00
5.1
4.00
7.5
-
108.0
102
2.6
76
2.3
102
3.4
-
4
4500
4.00
6.7 ---
--- 3.00
5.6
_
4.00
8.7
1.00
2.4
100
114.3
102
3.0
76
2.5
102
3.9
25
1.1
5
5.563
4.88
12.6
3.25
8.3
4.88
15.7
1.00
4.1
125
141.3
124
5.7
83
3.8
124
7.1
25
1.9
139.7mm
5.500
4.88
12A
3.25
8.2
4.88
15.4
-
139.7
124.0
5.6
82.6
3.7
124.0
6.9
-
159m In
6.250
5.50
12.6
3.50
9.2
5.50
17.9
-
158.8
140
5.7
89
4.2
140
8.0
-
6
6.625
5.50
18.3
3.50
11.7
5.50
22.7
1.00
5.9
150
168.3
140
8.3
89
5.3
140
10.3
25
2.7
165.1 mm
6500
5.43
17.6
3.50
11.4
5.50
22.0
-
165.1
139.7
7.9
88.9
5.2
139.7
9.9
-
8
8.625
6.81
25.5
4.25
20.4
6.94
38.7
1.13
12.7
200
219.1
_ 173
11.6
108
9.3
176
17.6
29
5.8
10.03 1539 Rev M Updated 1212014 02014 Victaulic Company. All rights reserved.
Victaulic.com 2 X ict:auhcr
victaulic.com I FireLock® Fittings I Publication 10.03
Flow Data:
' The flow data listed is based upon the pressure drop of Schedule 40 pipe.
General Notes:
NOTE: When assembling FireLock EZ couplings onto
end caps, take additional care to make certain the end
cap is fully seated against the gasket end stop. For
FireLock EZ Style 009N/009H couplings, use FireLock
No. 006 end caps containing the "EZ" marking on
the inside face or No. 60 end caps containing the "QV
EZ" marking on the inside face. Non-Victaulic end cap
products shall not be used with Style 009/009V/009H
couplings.
Installation
Reference should always be made to the 1100 Victaulic field Installation Handbcak for
the product you are Installing. Handbooks are included with each shipmelffol Well
products for complete installation and assembly data, and are available In PDF format
on our website at www.viclaulicoom.
WaRaaty
Refer to the Warranty section of the current Price List or contact Victaulic for details.
Note
This product shall be manufactured by Victaulic or to Victaulic specifications. All products
to be installed in accordance with current Vlclaullc Installation/assembly instructions.
Victaulic reserves the right to change product specifications, designs and standard
equipment without notice and without Incurring obligations.
Trademarks
Victaulic° is a registered trademark of Victaulic Company
10.03 1539 Rev M Updated 12/2014 0 2014 Victaulic Company. All rights reserved.
victaulic.com 3 rctaulrc'
Frictional Resistance
Actual
Equivalent Feat7meters of Straight Pipe'
No. 002
Nominal
Outside
Size
Diameter
Elbows
Straight Tee
No. 001
No. 003
Inches
Inches
mm
mm
90° Elbow
45° Elbow
Branch
Run
1'/4
1.660
-
-
-
-
32
42A
1 Va
1.900
-
-
-
-
40
48.3
2
2.375
3.5
1.8
8.5
3.5
50
60.3
1.1
0.5
2.6
11
2'h
2.875
_
4.3
2.2
_
10.8
_
4.3
65
73.0
1.3
0.7
3.3
1.3
76.1 mm
3.000
4.5
2.3
11.0
4.5
76.1
1.4
0.7
3.4
1.4
3
3.500
5.0
2.6
13.0
5.0
8088.9
1.5
0.8
4.0
1.5
_
108mm
_
4.250
6.4
3.2
15.3
6.4
108.0
2.0
0.9
4.7
2.0
4
4.500
6.8
3.4
16.0
6.8
100
114.3
2.1
1.0
4.9
2.1
5
5.563
8.5
4.2
21.0
8.5
125
141.3
2,15
1.3
6.4
2.6
139.7 mm
5.500
83
4.1
20.6
8.3
139.7
2.5
1.3
6.3
2.5
159mm
6.250
9.4
4.9
25.0
9.6
158.8
2.9
1.5
7.6
2.9.
6
6.625
_
10.0
5.0
_
25.0
10.0
150
168.3
3.0
1.5
7,15
3.0
165.1 mm
6.500
9.8
4.9
24.5
9.8
165.1
3.0
1.5
7.5
3.0
8
8.625
13.0
5.0
33.0
13.0
200
219.1
4.0
1.5
10.1
4.0
' The flow data listed is based upon the pressure drop of Schedule 40 pipe.
General Notes:
NOTE: When assembling FireLock EZ couplings onto
end caps, take additional care to make certain the end
cap is fully seated against the gasket end stop. For
FireLock EZ Style 009N/009H couplings, use FireLock
No. 006 end caps containing the "EZ" marking on
the inside face or No. 60 end caps containing the "QV
EZ" marking on the inside face. Non-Victaulic end cap
products shall not be used with Style 009/009V/009H
couplings.
Installation
Reference should always be made to the 1100 Victaulic field Installation Handbcak for
the product you are Installing. Handbooks are included with each shipmelffol Well
products for complete installation and assembly data, and are available In PDF format
on our website at www.viclaulicoom.
WaRaaty
Refer to the Warranty section of the current Price List or contact Victaulic for details.
Note
This product shall be manufactured by Victaulic or to Victaulic specifications. All products
to be installed in accordance with current Vlclaullc Installation/assembly instructions.
Victaulic reserves the right to change product specifications, designs and standard
equipment without notice and without Incurring obligations.
Trademarks
Victaulic° is a registered trademark of Victaulic Company
10.03 1539 Rev M Updated 12/2014 0 2014 Victaulic Company. All rights reserved.
victaulic.com 3 rctaulrc'