Loading...
HomeMy WebLinkAboutFS FIRELOCK FITTINGS PRODUCT INFO - 16-00683-684 - Sugar Mill ApartmentsFireLock® Fittings Approvais/Listings: o®m Q LP[B vas um Product Description: FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full -flow elbows and tees feature CAD - developed, hydrodynamic design, affording a shorter center -to -end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Refer to the appropriate listing agency or approval body for pressure ratings. Pressure ratings vary by agency. Job/Owner System No. Location Contractor Submitted By Date 10.03 Material Specifications: Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: ❑ Orange enamel ❑ Red enamel in Europe, Middle East, Africa, and India ❑ Optional: Hot dipped galvanized Engineer Spec Section Paragraph Approved Date victaulic.com I FireLock® Fittings I Publication 10.03 10.03 1539 Rev M Updated 12/2014 ® 2014 Victaulic Company. All rights reserved. 1 rCtaUI I victaulic.com I Fire Lock® Fittings I Publication 10.03 Dimensions: wC to E� C j ` to E'I ld p C1oE 1.E .Y/ eje to E .s NO. 001 N0.003 N0. 002 No. 006 10.03 1539 Rev M Updated 1212014 02014 Victaulic Company. All rights reserved. Victaulic.com 2 X ict:auhcr No. 001 No. 003 No. 002 No. 006 90° Elbow 45° Elbow Straight Tee Cap Actual ._ Approx.-- .._.._._, Approx. Approx. Approx. Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each C to E Each Inches Inches Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs. mm mm mm kq mm kg mm kg mm kg I Y4 1,660 0.82 0.3 32 42A - - - - - - 21 0.1 1 K 1.900 - - - - - - 0.82 0.4 40 48.3 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 2rh 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73D 76 1.4 1 57 1.0 1 76 1.6 22 0.5 76.1 mm 3.000 3.00 3.30 2.25 2.4 3.00 3.8 - 76.1 76 1.5 57 1.1 76.2 1.7 - 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 108mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 - 108.0 102 2.6 76 2.3 102 3.4 - 4 4500 4.00 6.7 --- --- 3.00 5.6 _ 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 139.7mm 5.500 4.88 12A 3.25 8.2 4.88 15.4 - 139.7 124.0 5.6 82.6 3.7 124.0 6.9 - 159m In 6.250 5.50 12.6 3.50 9.2 5.50 17.9 - 158.8 140 5.7 89 4.2 140 8.0 - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 165.1 mm 6500 5.43 17.6 3.50 11.4 5.50 22.0 - 165.1 139.7 7.9 88.9 5.2 139.7 9.9 - 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 _ 173 11.6 108 9.3 176 17.6 29 5.8 10.03 1539 Rev M Updated 1212014 02014 Victaulic Company. All rights reserved. Victaulic.com 2 X ict:auhcr victaulic.com I FireLock® Fittings I Publication 10.03 Flow Data: ' The flow data listed is based upon the pressure drop of Schedule 40 pipe. General Notes: NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009N/009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. Installation Reference should always be made to the 1100 Victaulic field Installation Handbcak for the product you are Installing. Handbooks are included with each shipmelffol Well products for complete installation and assembly data, and are available In PDF format on our website at www.viclaulicoom. WaRaaty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Vlclaullc Installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without Incurring obligations. Trademarks Victaulic° is a registered trademark of Victaulic Company 10.03 1539 Rev M Updated 12/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 3 rctaulrc' Frictional Resistance Actual Equivalent Feat7meters of Straight Pipe' No. 002 Nominal Outside Size Diameter Elbows Straight Tee No. 001 No. 003 Inches Inches mm mm 90° Elbow 45° Elbow Branch Run 1'/4 1.660 - - - - 32 42A 1 Va 1.900 - - - - 40 48.3 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 11 2'h 2.875 _ 4.3 2.2 _ 10.8 _ 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 8088.9 1.5 0.8 4.0 1.5 _ 108mm _ 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2,15 1.3 6.4 2.6 139.7 mm 5.500 83 4.1 20.6 8.3 139.7 2.5 1.3 6.3 2.5 159mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9. 6 6.625 _ 10.0 5.0 _ 25.0 10.0 150 168.3 3.0 1.5 7,15 3.0 165.1 mm 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 ' The flow data listed is based upon the pressure drop of Schedule 40 pipe. General Notes: NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009N/009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. Installation Reference should always be made to the 1100 Victaulic field Installation Handbcak for the product you are Installing. Handbooks are included with each shipmelffol Well products for complete installation and assembly data, and are available In PDF format on our website at www.viclaulicoom. WaRaaty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Vlclaullc Installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without Incurring obligations. Trademarks Victaulic° is a registered trademark of Victaulic Company 10.03 1539 Rev M Updated 12/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 3 rctaulrc'