HomeMy WebLinkAboutCOMCHECK - 16-00683-684 - Sugar Mill Apartments6 COMcheck Software Version 4.0.4.1 �( Envelope Compliance Certificate Project Information Energy Code: 2012 IECC Project Title: Sugar Mill Apts. Location: Rexburg, Idaho Climate Zone: 6b Project Type: New Construction Vertical Glazing /Wall Area: 80/0 Construction Site: Owner/Agent: Designer/Contractor: 267 W 4th S Rexburge, ID 83440 Building Area Floor Area 1 -Dormitory : Residential 21764 Additional Efficiency Package High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U - or R -Value R -Value U -Factor Factory.) Perimeter Roof 1: Attic Roof with Wood Joists, [Bldg. Use 1 - Dormitory] 5220 38.0 0.0 0.027 0.021 Exterior Wali 1: Wood -Framed, 16" o.c., [Bldg. Use 1 - Dormitory] 16440 21.0 0.0 0.062 0.051 Window 1: Vinyi/Fiberglass Frame:Operable, Pert. Specs.: Product ID 658 ••. --- 0.300 0.430 Tubelite, SHGC 0.39, [Bldg. Use t - Dormitory] (b) Window 2: Vinyl/Fiberglass Frame:Fixed, Ped. Specs.: Product ID 256 --- --- 0.300 0.360 Tubelite, SHGC 0.39, [Bldg. Use 1 - Dormitory] (b) Window 3: Vinyl/Fiberglass Frame:Flxed, Pert. Specs.: Product ID 448 --- --- 0.300 0.360 Tubelite, SHGC 0.39, [Bldg. Use.1 - Dormitory] (b) Door 1: Insulated Metal, Swinging, [Bldg. Use 1 - Dormitory] 332 --- --- 0.690 0.370 Basement Wall 1: Solid Concrete:10" Thickness, Normal Density, 1205 0.0 10.0 0.080 0.108 Furring: Wood, Wall Ht 9.8, Depth B.G. 9.5, [Bldg. Use 1 - Dormitory] Floor 1: Slab-On-Grade:Unheated, Vertical 3 ft., [Bldg. Use 1 - 5220 --- 20.0 0.472 0.520 Dormitory] (c) (a) Budget U -factors are used for. software baseline calculations ONLY, and are not code requirements. (b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c) Slab -On -Grade proposed and budget U -factors shown in table are F -factors. Envelope PASSES: Design 1 % better than code Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document Is consistent with the building plans, specifications, and other calculations submitted with this permit. application. The proposed envelope systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.4.1 and to comply with any applicable mandatory Project Title: Sugar Mill Apts. Report date: 10/05/16 Data filename: S:\Drawings\674-Sugar Mill Apt\05-BID\Com-Ck\Sugar Mill.cck Page 1 of 9 requirements listed in the Project Title: Sugar Mill Apts. Data filename: S:\Drawings\674-Sugar Mill Apt\05-BID\Com-Ck\Sugar Mill.cck Report date: 10/05/16 Page 2 of 9 COMcheck Software Version 4.0.4.1 Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? : Comments/Assumptions & Re .ID C103.2 ;Plans and/or specificationsprovide all ❑Complies [PR1]1 "information with which compliance ❑Does Not ;can be determined for the building❑Not ,envelope and document Observable; Applicable j ,exceptions to the standard are❑Not ,claimed. C406 ;Plans, specifications, and/or❑Complies [PR9]1 ;calculations provide all information❑Does Not ;with which compliance can be ;determined for the additional energy ❑Not Observable; efficiency package options.❑Not Applicable 0402.3.1 ;The vertical fenestration area <= 30❑Complies [PR30]1 1 percent of the gross above -grade wall❑Does Not ;area.❑Not Observable ❑Not Applicable C402.3.1 ;The skylight area <= 3 percent of the I❑Complies [PR11]1 :gross roof area. j❑Does Not ❑Not Observable ❑Not Applicable 0402.3.2. 'Skylights In office, storage,❑Complies 2 automotive service, manufacturing,❑Does Not [PR15]1 non -refrigerated warehouse, retail Observable: 'stare, and distribution/sorting area❑Not have a measured haze value > 900Not Applicable percent unless designed to exclude direct sunlight. Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 3 1 Low Impact(Tier 3) Project Title: Sugar Mill Apts. Report date: 10/05/16 Data filename: S:\Drawings\674-Sugar Mill Apt\05-BID\Com-Ck\Sugar Mill.cck Page 3 of 9 Section #Footing /.Foundation Inspection Complies? Comments/Assumptions & Req. ID� C402.2.4 Below-grade wall insulation R-value. ❑Complies ;See the Envelope Assemblies table for values. [FOS]?-❑Does Not -❑Not Observable ❑Not Applicable j 0303.2 ;Below-grade wall insulation Installed❑Complies [F02]2 !per manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable j C402.2.6 !Slab edge insulation R-value. ❑Complies ;See the Envelope Assemblies table for values. [F03]2 ❑Does Not ❑Not Observable I ❑Not Applicable C303.2.. iSlab edge insulation installed per ❑Complies [F0412 manufacturer's instructions. ❑Does Not I❑Not Observable ❑Not Applicable j C402.2.6 1Slab edge insulation depth/length.❑Complies ;See the Envelope Assemblies table for values. [F05]2 Slab insulation extending away from ❑Does Not building is covered by pavement or 1 >= 10 inches of soil. ❑Not Observable; ❑Not Applicable 0403.2.8. IExterior insulation protected against❑Complies 1 !damage, sunlight, moisture, wind,❑Does Not [F06]1 landscaping and equipment maintenance activities.❑Not Observable j❑Nat Applicable C402.2.8 ;Bottom surface of floor structures❑Complies ;See the Envelope Assemblies table for values. [FO12]3 :incorporating radiant heating ❑Does Not insulated to >=R-3.5.❑Not Observable; ❑Not Applicable Additional Comments/Assumptions., 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Sugar Mill Apts. Report date: 10/05/16 Data filename: S:\Drawings\674-Sugar Mill Apt\05-BID\Com-Ck\Sugar Mill.cck Page 4 of 9 Section # Framing / Rough -In Inspection Complies? Comments/Assumptions & Req.iD 0402.4.1, ;The building envelope contains a❑Complies C402.4.2 �contihuous air barrier that is sealed in ❑Does Not [FR1611 ;an approved manner and either ❑Not Observable ;constructed or tested in an approved : manner. Air barrier penetrations are ❑Not Applicable :sealed in an approved manner. C402.4.3, Factory -built fenestration and doors❑Complies 0402.4.4 are labeled as meeting air leakage ;❑Does Not [FR18]3 ;requirements.❑Not Observable; ❑Not Applicable j C402.4.7 ;Vestibules are installed on all building❑Complies [FR37]3 :entrances. Doors have self-closing ;❑Does Not devices. I❑Not Observable 1 ❑Not Applicable j 0402.3.3, ;Vertical fenestration U-Factor.❑Complies ;See the Envelope Assemblies table for values. 0402.3.4 ;❑Does Not [FR8]1 ❑Not Observable: j❑Not Applicable j C402.3.3 i 'Vertical fenestration SHGC value.❑Complies ;See the Envelope Assemblies table for values. [FR10]1 :❑Does Not :❑Not Observable ❑Not Applicable C303i1.3 ;.Fenestration products rated in ❑Complies [FR12]2 l accordance with NFRC. :[]Does Not - :❑Not Observable: ❑Not Applicable j 0303.1.3 Fenestration products are certified as❑Complies [FR13]1 to performance labels or certificates ;❑Does Not ; provided. ❑Not Observable: ❑Not Applicable j C402.2.7 U -factor of opaque doors associated ❑Complies ;See the Envelope Assemblies table for values. [FR14]2.; with the building thermal envelope❑Does Not meets requirements. I❑Not Observable: ❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 ILow Impact (Tier 3) Project Title: Sugar Mill Apts. Report date: 10/05/16 Data filename: S:\Drawings\674-Sugar Mill Apt\05-BID\Com-Ck\Sugar MIII.cck Page 5 of 9 section # Mechanical Rough -in Inspection Complies? Comments/Assumptions & Re q.ID C402.4.5. Stair and elevator shaftvents have ❑Complies 1 .motorized dampers that automatically❑Does Not [ME3]3 close. j❑Not Observable C402.4.5. ;Outdoor air and exhaust systems have;❑Complies 2 motorized dampers that automatically❑Does Not [ME58]3 ;shut when not in use and meet ;maximum leakage rates. Check Observable jgravity dampers where allowed. ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Sugar Mill Apts. Report date: 10/05/16 Data filename: S:\Drawings\674-Sugar Mill Apt\05-BID\Cam-Ck\Sugar Mill.cck Page 6 of 9 Section # Insulation Inspection Complies? Comments/Assumptions & Req.ID C402.4.1. ;All sources of air leakage In the ❑Complies 1 !building thermal envelope are sealed,❑Does Not [IN3]1 ;caulked, gasketed, weather stripped ❑Not Observable or wrapped with moisture vapor- permeable wrapping material to ❑Not Applicable minimize air leakage. C402.4.2.' Roof R-value. For some ceiling !❑Complies; See the Envelope Assemblies table for values. 1 .systems, verification may need to❑Does Not [IN2]1 loccur during Framing Inspection. ❑Not Observable j❑Not Applicable C303.2 'Roof insulation installed per❑Complies [IN3]1 !manufacturer's instructions. Blown or ❑Does Not ;poured loose-fill insulation is installed ' (only where the roof slope is <=3 in❑Not Observable; Applicable 112. ;❑Not C303.2 ;Above-grade wall insulation installed❑Complies [IN7]1 per manufacturer's instructions.❑Does Not I❑Not Observable I ❑Not Applicable 0402.2.5 ;Floorinsulation R-Value.❑Complies ; See the Envelope Assemblies table for values. [IN8]2❑Does Not ❑Not Observable I ❑Not Applicable 0303.1 Building envelope insulation is labeled ❑Complies [IN10]1 :with R-value or insulation certificate ;❑Does Not j providing R-value and other relevant ❑Not Observable data. ❑Not Applicable 0303.2.1- ;Exterior insulation is protected from ;❑Complies [IN14]2. damage with protective material. j❑Does Not Verification for exposed foundation - insulation may need to occur during❑Not Observable I ❑Not Applicable Foundation Inspection. 0402.2.1 Insulation intended to meet the roof❑Complies [IN17]3 :insulation requirements cannot be❑Does Not installed on top of a suspended .ceiling. Mark this requirement i I I❑Not Observable ,compliant if insulation is installed❑Not Applicable accordingly. Additional Comments/Assumptions: 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Sugar Mill Apts. Report date: 10/05/16 Data filename: S:\Drawings\674-Sugar Mill Apt\05-BID\Com-Ck\Sugar Mill.cck Page 7 of 9 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C402.4.6 Weatherseals installed on all loading❑Complies [F137]1 dock cargo doors. ,❑Does Not ❑Not Observable; ![]Not Applicable j 0402.4.8 ',Recessed luminaires In thermal❑Complies [F126]3 !envelope to limit infiltration and be IC❑Does Not rated and labeled. Seal between interior finish and luminaire housing.❑Not Observable I ❑Not Applicable 0406 ,Efficient HVAC performance, efficient ❑Complies [FI34]1 11ghting system, or on-site supply of j❑Does Not ;renewable energy consistent with ❑Not Observable', ;what is shown the approved plans. ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Sugar Mill Apts. Report date: 10/05/16 Data filename: S:\Drawings\674-Sugar MITI Apt\05-BID\Com-Ck\Sugar Mill.cck Page 8 of 9 Project Title: Sugar Mill Apts. Report date: 10/05/16 Data filename: S:\Drawings\674-Sugar Mill Apt\05-BID\Com-Ck\Sugar Mill.cck Page 9 of 9