�( Envelope Compliance Certificate
Project Information
Energy Code:
2012 IECC
Project Title:
Sugar Mill Apts.
Location:
Rexburg, Idaho
Climate Zone:
6b
Project Type:
New Construction
Vertical Glazing /Wall Area:
80/0
Construction Site: Owner/Agent: Designer/Contractor:
267 W 4th S
Rexburge, ID 83440
Building Area Floor Area
1 -Dormitory : Residential 21764
Additional Efficiency Package
High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist
report.
Envelope Assemblies
Assembly
Gross Area Cavity Cont. Proposed Budget U -
or R -Value R -Value U -Factor Factory.)
Perimeter
Roof 1: Attic Roof with Wood Joists, [Bldg. Use 1 - Dormitory] 5220 38.0 0.0 0.027 0.021
Exterior Wali 1: Wood -Framed, 16" o.c., [Bldg. Use 1 - Dormitory] 16440 21.0 0.0 0.062 0.051
Window 1: Vinyi/Fiberglass Frame:Operable, Pert. Specs.: Product ID 658 ••. --- 0.300 0.430
Tubelite, SHGC 0.39, [Bldg. Use t - Dormitory] (b)
Window 2: Vinyl/Fiberglass Frame:Fixed, Ped. Specs.: Product ID 256 --- --- 0.300 0.360
Tubelite, SHGC 0.39, [Bldg. Use 1 - Dormitory] (b)
Window 3: Vinyl/Fiberglass Frame:Flxed, Pert. Specs.: Product ID 448 --- --- 0.300 0.360
Tubelite, SHGC 0.39, [Bldg. Use.1 - Dormitory] (b)
Door 1: Insulated Metal, Swinging, [Bldg. Use 1 - Dormitory] 332 --- --- 0.690 0.370
Basement Wall 1: Solid Concrete:10" Thickness, Normal Density, 1205 0.0 10.0 0.080 0.108
Furring: Wood, Wall Ht 9.8, Depth B.G. 9.5, [Bldg. Use 1 - Dormitory]
Floor 1: Slab-On-Grade:Unheated, Vertical 3 ft., [Bldg. Use 1 - 5220 --- 20.0 0.472 0.520
Dormitory] (c)
(a) Budget U -factors are used for. software baseline calculations ONLY, and are not code requirements.
(b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
(c) Slab -On -Grade proposed and budget U -factors shown in table are F -factors.
Envelope PASSES: Design 1 % better than code
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document Is consistent with the building plans,
specifications, and other calculations submitted with this permit. application. The proposed envelope systems have been
designed to meet the 2012 IECC requirements in COMcheck Version 4.0.4.1 and to comply with any applicable mandatory
Project Title: Sugar Mill Apts. Report date: 10/05/16
Data filename: S:\Drawings\674-Sugar Mill Apt\05-BID\Com-Ck\Sugar Mill.cck Page 1 of 9
requirements listed in the
Project Title: Sugar Mill Apts.
Data filename: S:\Drawings\674-Sugar Mill Apt\05-BID\Com-Ck\Sugar Mill.cck
Report date: 10/05/16
Page 2 of 9
COMcheck Software Version 4.0.4.1
Inspection Checklist
Energy Code: 2012 IECC
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
#
Plan Review
Complies? : Comments/Assumptions
& Re .ID
C103.2
;Plans and/or specificationsprovide all
❑Complies
[PR1]1
"information with which compliance
❑Does Not
;can be determined for the building❑Not
,envelope and document
Observable;
Applicable j
,exceptions to the standard are❑Not
,claimed.
C406
;Plans, specifications, and/or❑Complies
[PR9]1
;calculations provide all information❑Does
Not
;with which compliance can be
;determined for the additional energy
❑Not Observable;
efficiency package options.❑Not
Applicable
0402.3.1
;The vertical fenestration area <= 30❑Complies
[PR30]1
1 percent of the gross above -grade wall❑Does
Not
;area.❑Not
Observable
❑Not Applicable
C402.3.1
;The skylight area <= 3 percent of the
I❑Complies
[PR11]1
:gross roof area.
j❑Does Not
❑Not Observable
❑Not Applicable
0402.3.2.
'Skylights In office, storage,❑Complies
2
automotive service, manufacturing,❑Does
Not
[PR15]1
non -refrigerated warehouse, retail
Observable:
'stare, and distribution/sorting area❑Not
have a measured haze value > 900Not
Applicable
percent unless designed to exclude
direct sunlight.
Additional Comments/Assumptions:
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Sugar Mill Apts. Report date: 10/05/16
Data filename: S:\Drawings\674-Sugar Mill Apt\05-BID\Com-Ck\Sugar Mill.cck Page 3 of 9
Section
#Footing
/.Foundation Inspection
Complies? Comments/Assumptions
& Req. ID�
C402.2.4
Below-grade wall insulation R-value.
❑Complies ;See the Envelope Assemblies table for values.
[FOS]?-❑Does
Not
-❑Not
Observable
❑Not Applicable j
0303.2
;Below-grade wall insulation Installed❑Complies
[F02]2
!per manufacturer's instructions.
❑Does Not
❑Not Observable
❑Not Applicable j
C402.2.6
!Slab edge insulation R-value.
❑Complies ;See the Envelope Assemblies table for values.
[F03]2
❑Does Not
❑Not Observable I
❑Not Applicable
C303.2..
iSlab edge insulation installed per
❑Complies
[F0412
manufacturer's instructions.
❑Does Not
I❑Not Observable
❑Not Applicable j
C402.2.6
1Slab edge insulation depth/length.❑Complies
;See the Envelope Assemblies table for values.
[F05]2
Slab insulation extending away from
❑Does Not
building is covered by pavement or 1
>= 10 inches of soil.
❑Not Observable;
❑Not Applicable
0403.2.8.
IExterior insulation protected against❑Complies
1
!damage, sunlight, moisture, wind,❑Does
Not
[F06]1
landscaping and equipment
maintenance activities.❑Not
Observable
j❑Nat Applicable
C402.2.8
;Bottom surface of floor structures❑Complies
;See the Envelope Assemblies table for values.
[FO12]3
:incorporating radiant heating
❑Does Not
insulated to >=R-3.5.❑Not
Observable;
❑Not Applicable
Additional Comments/Assumptions.,
11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Sugar Mill Apts. Report date: 10/05/16
Data filename: S:\Drawings\674-Sugar Mill Apt\05-BID\Com-Ck\Sugar Mill.cck Page 4 of 9
Section
#
Framing / Rough -In Inspection
Complies? Comments/Assumptions
& Req.iD
0402.4.1,
;The building envelope contains a❑Complies
C402.4.2
�contihuous air barrier that is sealed in
❑Does Not
[FR1611
;an approved manner and either
❑Not Observable
;constructed or tested in an approved
: manner. Air barrier penetrations are
❑Not Applicable
:sealed in an approved manner.
C402.4.3,
Factory -built fenestration and doors❑Complies
0402.4.4
are labeled as meeting air leakage
;❑Does Not
[FR18]3
;requirements.❑Not
Observable;
❑Not Applicable j
C402.4.7
;Vestibules are installed on all building❑Complies
[FR37]3
:entrances. Doors have self-closing
;❑Does Not
devices.
I❑Not Observable 1
❑Not Applicable j
0402.3.3,
;Vertical fenestration U-Factor.❑Complies
;See the Envelope Assemblies table for values.
0402.3.4
;❑Does Not
[FR8]1
❑Not Observable:
j❑Not Applicable j
C402.3.3
i 'Vertical fenestration SHGC value.❑Complies
;See the Envelope Assemblies table for values.
[FR10]1
:❑Does Not
:❑Not Observable
❑Not Applicable
C303i1.3
;.Fenestration products rated in
❑Complies
[FR12]2
l accordance with NFRC.
:[]Does Not
-
:❑Not Observable:
❑Not Applicable j
0303.1.3
Fenestration products are certified as❑Complies
[FR13]1
to performance labels or certificates
;❑Does Not
; provided.
❑Not Observable:
❑Not Applicable j
C402.2.7
U -factor of opaque doors associated
❑Complies ;See the Envelope Assemblies table for values.
[FR14]2.;
with the building thermal envelope❑Does
Not
meets requirements.
I❑Not Observable:
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 ILow Impact (Tier 3)
Project Title: Sugar Mill Apts. Report date: 10/05/16
Data filename: S:\Drawings\674-Sugar Mill Apt\05-BID\Com-Ck\Sugar MIII.cck Page 5 of 9
section
# Mechanical Rough -in Inspection Complies? Comments/Assumptions
& Re q.ID
C402.4.5. Stair and elevator shaftvents have ❑Complies
1 .motorized dampers that automatically❑Does Not
[ME3]3 close. j❑Not Observable
C402.4.5. ;Outdoor air and exhaust systems have;❑Complies
2 motorized dampers that automatically❑Does Not
[ME58]3 ;shut when not in use and meet
;maximum leakage rates. Check Observable
jgravity dampers where allowed. ❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Sugar Mill Apts. Report date: 10/05/16
Data filename: S:\Drawings\674-Sugar Mill Apt\05-BID\Cam-Ck\Sugar Mill.cck Page 6 of 9
Section
#
Insulation Inspection
Complies? Comments/Assumptions
& Req.ID
C402.4.1.
;All sources of air leakage In the
❑Complies
1
!building thermal envelope are sealed,❑Does
Not
[IN3]1
;caulked, gasketed, weather stripped
❑Not Observable
or wrapped with moisture vapor-
permeable wrapping material to
❑Not Applicable
minimize air leakage.
C402.4.2.'
Roof R-value. For some ceiling
!❑Complies; See the Envelope Assemblies table for values.
1
.systems, verification may need to❑Does
Not
[IN2]1
loccur during Framing Inspection.
❑Not Observable
j❑Not Applicable
C303.2
'Roof insulation installed per❑Complies
[IN3]1
!manufacturer's instructions. Blown or
❑Does Not
;poured loose-fill insulation is installed
'
(only where the roof slope is <=3 in❑Not
Observable;
Applicable
112.
;❑Not
C303.2
;Above-grade wall insulation installed❑Complies
[IN7]1
per manufacturer's instructions.❑Does
Not
I❑Not Observable I
❑Not Applicable
0402.2.5
;Floorinsulation R-Value.❑Complies
; See the Envelope Assemblies table for values.
[IN8]2❑Does
Not
❑Not Observable I
❑Not Applicable
0303.1
Building envelope insulation is labeled
❑Complies
[IN10]1
:with R-value or insulation certificate
;❑Does Not
j providing R-value and other relevant
❑Not Observable
data.
❑Not Applicable
0303.2.1-
;Exterior insulation is protected from
;❑Complies
[IN14]2.
damage with protective material.
j❑Does Not
Verification for exposed foundation
-
insulation may need to occur during❑Not
Observable I
❑Not Applicable
Foundation Inspection.
0402.2.1
Insulation intended to meet the roof❑Complies
[IN17]3
:insulation requirements cannot be❑Does
Not
installed on top of a suspended
.ceiling. Mark this requirement
i I
I❑Not Observable
,compliant if insulation is installed❑Not
Applicable
accordingly.
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Sugar Mill Apts. Report date: 10/05/16
Data filename: S:\Drawings\674-Sugar Mill Apt\05-BID\Com-Ck\Sugar Mill.cck Page 7 of 9
Section
#
Final Inspection
Complies? Comments/Assumptions
& Req.ID
C402.4.6
Weatherseals installed on all loading❑Complies
[F137]1
dock cargo doors.
,❑Does Not
❑Not Observable;
![]Not Applicable j
0402.4.8
',Recessed luminaires In thermal❑Complies
[F126]3
!envelope to limit infiltration and be IC❑Does
Not
rated and labeled. Seal between
interior finish and luminaire housing.❑Not
Observable I
❑Not Applicable
0406
,Efficient HVAC performance, efficient
❑Complies
[FI34]1
11ghting system, or on-site supply of
j❑Does Not
;renewable energy consistent with
❑Not Observable',
;what is shown the approved plans.
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Sugar Mill Apts. Report date: 10/05/16
Data filename: S:\Drawings\674-Sugar MITI Apt\05-BID\Com-Ck\Sugar Mill.cck Page 8 of 9