Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PLANS - 17-00416 - Walmart - Cell Tower
WALMART REXBURG ID6 1450 NORTH 2ND E. REXBURG, IDAHO 83440 OF 14 SMALL CELL CONSTRUCTION DRAWINGS TITLE SHEET T-1 1 07/19/17 D D D D D D D D D D D D D D D D D D D D V V V V V V V V V V RD RD RDRD RDRDRDRDRDRDRDRD V V V V V RDRDRDRD A C A C A C A C A C A C A C A C A C A C A C A C A C A C A C ACAC ACAC AC AC A C A C A C A C A C A C A C A C A C A C A C A C A C A C A C A C A C D D D D D DD D V V ET CA B D WV W WV WV H Y D H Y D WV D Know what's below. Call before you dig. GENERAL NOTES: OF 14 1 Z-1 SITE PLAN SCALE: 1"=60'-0" SITE PLAN Z-1 2 1 Z-2 LONG LAT SITE COORDINATES 111° 46' 25.862" WEST (NAD 83) 43° 51' 21.986" NORTH (NAD 83) N 07/19/17 D V V V RDRDRDRDRDRDRDRD V V A C A C A C A C ACAC AC AC AC AC V V D Know what's below. Call before you dig. OF 14 1 Z-2 ENLARGED SITE PLAN SCALE: 1"=20'-0" ENLARGED SITE PLAN Z-2 3 N 07/19/17 GENERAL NOTES: OF 14 Know what's below. Call before you dig. 1 C-1 EQUIPMENT PLAN SCALE: 3/4"=1'-0" EQUIPMENT PLAN C-1 4 N 1 C-3 2 C-3 OVP DESIGNATION CABLE TABLE 390' LENGTH 1 NO.TYPECONDUIT 3-CELL PLENUM FIBER IN CONDUIT 4" FIBER RUN 200' 1 2" HYBRIFLEX 6x12 LOW INDUCTANCE SIZE MAXCELL INNERDUCT BUFFER TOTAL 30' 30' 420' 230' 07/19/17 OF 14 Know what's below. Call before you dig. 1 C-2 EXISTING ELEVATION SCALE: 3/16"=1'0" EXISTING ELEVATION C-2 5 07/19/17 OF 14 Know what's below. Call before you dig. 2 C-3 PERSPECTIVE ELEVATION SCALE: N.T.S. PROPOSED ELEVATIONS C-3 6 1 C-3 LINE OF SIGHT ELEVATION SCALE: 1/4"=1'-0" NOTE: THIS ELEVATION IS NOT DRAWN TO SCALE. IT IS A VISUAL REPRESENTATION OF HOW THE SITE WOULD APPEAR TO A 5'-8" PERSON STANDING 50'-0" AWAY. 07/19/17 OF 14 1 C-4 COMMSCOPE SMALL CELL CABINET N.T.S. 2 C-4 CONDUIT ATTACHMENT DETAIL N.T.S. 3 C-4 WALL PENETRATION DETAIL N.T.S. Know what's below. Call before you dig. CONSTRUCTION DETAILS C-4 7 5 C-4 EME SIGNAGE DETAIL N.T.S. 4 C-4 CABLE ATTACHMENT DETAIL N.T.S. 07/19/17 OF 14 Know what's below. Call before you dig. CONSTRUCTION DETAILS (CONTINUED) C-5 8 4 C-5 UTILITY TRENCH DETAIL N.T.S. 7 C-5 PULLBOX DETAIL N.T.S. 2 C-5 1 C-5 TRANSFORMER CONCRETE PAD N.T.S. 2 C-5 CONCRETE PAD SECTION N.T.S. 6 C-5 CONCRETE FILLED BOLLARD DETAIL N.T.S. 5 C-5 3 C-5 EQUIPMENT CABINET CONCRETE PAD N.T.S. 5 C-5 CONCRETE PAD SECTION N.T.S. 07/19/17 OF 14 N 2 A-1 ANTENNA MOUNTING DETAIL N.T.S. 1 A-1 PROPOSED ANTENNA LAYOUT N.T.S. ANTENNA SCHEDULE & MOUNTING PLAN A-1 9 3 A-1 PLUMBING DIAGRAM N.T.S. ANTENNA & CABLE SCHEDULE SECTOR AZIMUTH MOUNTING HEIGHT ANTENNA MODEL TECHNOLOGY ANTENNA SPECIFICATIONS MECHANICAL DOWNTILT ELECTRICAL DOWNTILT CABLE SIZE CABLE LENGTH 07/19/17 Module 1 555-960 Module 1 1695-2690 Module 2 555-960 Module 2 1695-2690 Module 1 COM Module 2 COM OF 14 1 A-2 OVP DETAIL N.T.S. Know what's below. Call before you dig. OVP & REMOTE RADIO HEAD DETAILS A-2 10 2 A-2 AWS RRH DETAIL N.T.S. 4 A-2 TWIN DIPLEXER DETAIL N.T.S. 3 A-2 700 RRH DETAIL N.T.S. 07/19/17 ELECTRICAL SPECIFICATIONS GENERAL REQUIREMENTS DRAWINGS ARE DIAGRAMMATIC AND DO NOT INDICATE ALL FITTINGS, JUNCTION BOXES, ETC. REQUIRED. PROVIDE ALL REQUIRED EQUIPMENT, CONDUIT, FITTINGS, WIRING, BOXES, ETC. FOR A COMPLETE AND OPERATIONAL INSTALLATION. WORK AND EQUIPMENT SHALL COMPLY WITH STATE AND LOCALLY ADOPTED CODES AND STANDARDS, INCLUDING THE 2014 NATIONAL ELECTRICAL CODE (NEC), INTERNATIONAL CODES (I-CODES), AND LOCAL AMENDMENTS. ANYTHING DRAWN OR SPECIFIED SHALL NOT BE CONSTRUED TO CONFLICT WITH STATE AND LOCALLY ADOPTED CODES AND STANDARDS, INCLUDING THE NATIONAL ELECTRICAL CODE, WHICH GOVERNS THE INSTALLATION OF ANY ELECTRICAL WORK. ITEMS SHALL NOT BE INSTALLED IN CONFLICT WITH THE NEC. RESOLVE ANY AND ALL CONFLICTS PRIOR TO INSTALLATION. BECOME THOROUGHLY ACQUAINTED WITH THE CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED. EXAMINE ALL SERVICES, EQUIPMENT, AND EXISTING CONDITIONS, WHICH THIS WORK IS IN ANY WAY DEPENDENT UPON, AND BRING ANY DISCREPANCIES OR OMISSIONS FOUND IN THE DRAWINGS TO THE ELECTRICAL ENGINEER'S ATTENTION PRIOR TO SUBMITTING BID. PROVIDE DRAWINGS TO LOCAL BUILDING AUTHORITY AND OBTAIN A PERMIT PRIOR TO STARTING ANY WORK. NOTIFY ELECTRICAL ENGINEER OF ANY CHANGES REQUESTED BY THE LOCAL BUILDING AUTHORITY IMMEDIATELY AND PRIOR TO STARTING WORK. VERIFY AND COMPLY WITH UTILITY COMPANY REQUIREMENTS. PROVIDE METERING, CONNECTION CABINETS, CT CABINETS, AND TRANSFORMER AND CONNECTION CABINET PADS PER LOCAL UTILITY COMPANY REQUIREMENTS. PROVIDE A REDLINED AS-BUILT SET OF ELECTRICAL DRAWINGS TO OWNER UPON COMPLETION OF WORK. ELECTRICAL WORK SHOWN LIGHT OR MARKED "E" IS EXISTING, SHOWN DARK IS NEW, AND SHOWN DASHED IS EXISTING TO BE REMOVED OR RELOCATED UNLESS OTHERWISE INDICATED. DASHING MAY ALSO INDICATE UNDER FLOOR OR UNDER GROUND CONDUIT. IF UNCLEAR, CONTACT ELECTRICAL ENGINEER FOR CLARIFICATION. EQUIPMENT, WIRING, AND DEVICES SHOWN ARE NEW UNLESS OTHERWISE NOTED. MAINTAIN CIRCUITING TO EXISTING EQUIPMENT AND DEVICES TO REMAIN. INSTALL EQUIPMENT AND DEVICES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. NOTIFY ELECTRICAL ENGINEER, PRIOR TO INSTALLING EQUIPMENT AND DEVICES, IF MANUFACTURER'S INSTALLATION INSTRUCTIONS CONFLICT WITH ELECTRICAL INFORMATION ON THE THESE DRAWINGS. ELECTRICALLY OPERATED EQUIPMENT SHOWN ON PLANS, AND NOT CIRCUITED ON THE ELECTRICAL PLANS, WILL REQUIRE ELECTRICAL SERVICE. CONTACT ELECTRICAL ENGINEER FOR CONNECTION REQUIREMENTS AND CLARIFICATION PRIOR TO BID. THE COST FOR THIS WORK SHALL BE INCLUDED IN THE BID. PROVIDE HANGERS AND SUPPORTS TO ADEQUATELY AND SECURELY SUPPORT ELECTRICAL SYSTEM COMPONENTS IN A NEAT AND WORKMANLIKE MANNER. MAINTAIN THE FIRE RATING OF THE ASSEMBLY (CEILING, WALL, OR FLOOR) IN WHICH EQUIPMENT, WIRING, AND DEVICES ARE TO BE INSTALLED. EQUIPMENT SHALL BE FULLY RATED FOR THE AMBIENT CONDITIONS (ELEVATION, TEMPERATURE, WIND LOAD, SOIL CONDITIONS, ETC) AT THE PROJECT LOCATION. KEEP PRODUCTS IN ORIGINAL MANUFACTURER'S PACKAGING AND PROTECT FROM DAMAGE UNTIL READY FOR INSTALLATION. PROVIDE PRODUCTS LISTED AND CLASSIFIED BY NATIONALLY RECOGNIZED TESTING LABORATORY (UL OR EQUAL) AS SUITABLE FOR THE PURPOSE SPECIFIED AND INDICATED. UNLESS SPECIFICALLY INDICATED TO BE EXCLUDED, PROVIDE ALL REQUIRED CONDUIT, BOXES, WIRING, CONNECTORS, HARDWARE, SUPPORTS, TRIMS, ACCESSORIES, ETC. AS NECESSARY FOR COMPLETE AND OPERATIONAL SYSTEMS. SUBMITTALS AND SUBSTITUTIONS PROVIDE PRODUCT DATA SHEETS AND SHOP DRAWINGS FOR EQUIPMENT, FIXTURES, AND DEVICES TO ELECTRICAL ENGINEER PRIOR TO PURCHASING. REVIEW, STAMP AND INITIAL ALL ELECTRICAL SUBMITTALS AND SHOP DRAWINGS CERTIFYING THAT THE SUBMITTALS HAVE BEEN REVIEWED PRIOR TO SUBMITTING TO ELECTRICAL ENGINEER FOR REVIEW. EQUIPMENT AND FIXTURES SPECIFIED REPRESENT REQUIRED QUALITY AND PERFORMANCE. PROVIDE PRODUCT DATA SHEETS AND SHOP DRAWING OF PROPOSED SUBSTITUTIONS TO SPECIFIED EQUIPMENT TO ELECTRICAL ENGINEER FOR REVIEW. ELECTRICAL ENGINEER SHALL DETERMINE THE ACCEPTABILITY OF SUBSTITUTIONS TO SPECIFIED EQUIPMENT. REVIEW, STAMP AND INITIALED ALL ELECTRICAL SUBMITTALS AND SHOP DRAWINGS CERTIFYING THAT SUBMITTALS HAVE BEEN REVIEWED PRIOR TO SUBMITTING TO ELECTRICAL ENGINEER FOR REVIEW. SUBMITTALS AND SHOP DRAWINGS ARE TO INCLUDE THE FOLLOWING: KEY TO PLAN DESIGNATIONS, MANUFACTURER, MODEL NUMBER, DATA SHEETS, QUANTITIES, COLORS, LABELS, DIMENSIONS, INSTALLATION INSTRUCTIONS, AND ANY ADDITIONAL INFORMATION REQUIRED TO DETERMINE IF THE PRODUCT MEETS THE DESIGN INTENT. CONSTRUCTION PHASE REVIEW REQUIREMENTS INSTALL POWER, LIGHTING, COMMUNICATIONS AND SPECIAL SYSTEM (FIRE ALARM, SECURITY, BUILDING AUTOMATION, ETC) BOXES PRIOR TO RUNNING CABLE OR CONDUIT TO BOXES. ARRANGE FOR OWNER, ARCHITECT, AND ENGINEER TO REVIEW BOX LOCATIONS PRIOR TO RUNNING CABLE OR CONDUIT TO BOXES. ADJUST BOXES AS DIRECTED BY OWNER, ARCHITECT, AND ENGINEER. REQUESTS FOR MODIFICATIONS TO THE CONTRACT (CHANGE ORDERS) REQUESTS BY CONTRACTOR FOR ADDITION OR REDUCTION TO THE CONTRACT AMOUNT SHALL BE ACCOMPANIED BY THE FOLLOWING FOR EVALUATION BY THE OWNER AND ENGINEER: 1.ORIGIN AND DATE OF CLAIM 2.QUANTITIES OF PRODUCTS, LABOR, AND EQUIPMENT 3.DOLLAR AMOUNT OF TAXES, OVERHEAD, AND PROFIT 4.JUSTIFICATION FOR ANY CHANGE IN CONTRACT TIME 5.CREDIT AMOUNT FOR DELETIONS (WITH DOCUMENTATION) 6.DATES AND TIMES OF WORK PERFORMED, AND BY WHOM 7.TIME RECORDS AND WAGE RATES PAID 8.INVOICES AND RECEIPTS FOR PRODUCTS AND EQUIPMENT SUBMIT ALL DOCUMENTATION TO ENGINEER AND OWNER, AND OBTAIN WRITTEN APPROVAL PRIOR TO STARTING ANY WORK THAT AFFECTS THE CONTRACT AMOUNT OR COMPLETION DATE. EXISTING CONDITIONS THESE DRAWINGS CONTAIN INFORMATION REGARDING EXISTING CONDITIONS. THIS INFORMATION WAS COMPILED FROM EXISTING DRAWINGS, CASUAL FIELD OBSERVATIONS OR INFORMATION PROVIDED BY OTHERS. IN SOME CASES, ASSUMPTIONS WERE MADE WHEN FIELD OBSERVATIONS OR EXISTING DRAWINGS DID NOT PROVIDE NECESSARY INFORMATION (I.E. LOCKED DISCONNECTS, NO WIRE SIZE INDICATED, NAMEPLATE DATA MISSING, INACCURATE AS-BUILT DRAWINGS, ETC.). EXISTING CONDITIONS SHALL BE VERIFIED AND ALLOWED FOR PRIOR TO BID AND CONSTRUCTION. NOTIFY THE ELECTRICAL ENGINEER OF ANY DISCREPANCIES WITH THESE DRAWINGS IMMEDIATELY AND PRIOR TO COMMENCING ANY FURTHER WORK. COORDINATION OBTAIN AND REVIEW SHOP DRAWINGS, PRODUCT DATA, MANUFACTURER'S WIRING DIAGRAMS AND MANUFACTURER'S INSTRUCTIONS FOR EQUIPMENT PROVIDED BY OTHERS. THE FINAL LOCATION OF EQUIPMENT SHALL BE COORDINATED IN THE FIELD, PRIOR TO ROUGH-IN, TO MEET APPLICABLE LOCATION, HEIGHT AND CLEARANCE REQUIREMENTS. MAINTAINING EXISTING SERVICES MAINTAIN THE ELECTRICAL SERVICE TO EXISTING TENANTS AND AREAS. ANY SERVICE DISCONTINUITY SHALL BE COORDINATED AND APPROVED BY OWNER AND TENANTS PRIOR TO OUTAGE. IF REQUIRED, PROVIDE TEMPORARY POWER DURING OUTAGE. WIRING AND CONDUIT NEW WIRING SHALL BE THHN/THWN-2, 90°C INSULATED COPPER UNLESS OTHERWISE NOTED. ALUMINUM CONDUCTORS SHALL BE XHHW-2, INSULATED COMPACT STRAND. THE MAXIMUM NUMBER OF CONDUCTORS IN A CONDUIT FOR A 3Ø SYSTEM SHALL BE THREE (AØ, BØ, CØ), NOT INCLUDING NEUTRAL AND EQUIPMENT GROUNDING CONDUCTORS, UNLESS OTHERWISE INDICATED. CONDUIT SIZE SHALL BE BASED UPON NEC CHAPTER 9 AND ANNEX C. MORE THAN 3 CURRENT-CARRYING CONDUCTORS MAY BE INSTALLED IN A RACEWAY IF THE APPROPRIATE AMPACITY-DERATING FACTORS ARE APPLIED. THE MAXIMUM NUMBER OF CONDUCTORS IN A CONDUIT FOR A 1Ø SYSTEM SHALL BE TWO (AØ, BØ), NOT INCLUDING NEUTRAL AND EQUIPMENT GROUNDING CONDUCTORS UNLESS OTHERWISE INDICATED. CONDUIT SIZE SHALL BE BASED UPON NEC CHAPTER 9 AND ANNEX C. MORE THAN 3 CURRENT-CARRYING CONDUCTORS MAY BE INSTALLED IN A RACEWAY IF THE APPROPRIATE AMPACITY-DERATING FACTORS ARE APPLIED. PROVIDE A DEDICATED NEUTRAL FOR EACH LINE-TO-NEUTRAL CIRCUIT UNLESS A MULTI-POLE BREAKER, WHICH DISCONNECTS ALL PHASE CONDUCTORS THAT SHARE A NEUTRAL, IS PROVIDED (LISTED BREAKER-TIES ARE PERMITTED). PROVIDE AN INSULATED EQUIPMENT GROUNDING CONDUCTOR WITH ALL FEEDERS AND BRANCH-CIRCUIT WIRING. INCREASE CONDUIT SIZE AS REQUIRED TO ACCOMMODATE EQUIPMENT GROUNDING CONDUCTOR. PROVIDE ALL CONDUIT, FITTINGS, SUPPORTS, AND ACCESSORIES REQUIRED FOR A COMPLETE RACEWAY SYSTEM. CONDUIT SHALL BE CONCEALED IN WALLS, FLOOR OR CEILING IN FINISHED AREAS UNLESS OTHERWISE INDICATED. IN FINISHED AREAS, WHERE CONDUIT AND CABLE CAN NOT BE CONCEALED IN WALLS OR CEILINGS (I.E. EXISTING MASONRY CONSTRUCTION), PROVIDE WIREMOLD OR EQUAL SURFACE MOUNTED RACEWAY AS APPROVED BY ARCHITECT OR ENGINEER. UNLESS OTHERWISE INDICATED AND WHERE NOT OTHERWISE RESTRICTED, USE THE CONDUIT TYPES INDICATED BELOW FOR THE SPECIFIED APPLICATIONS. WHERE MORE THAN ONE LISTED APPLICATION APPLIES, COMPLY WITH THE MOST RESTRICTIVE REQUIREMENTS. WHERE CONDUIT TYPE FOR A PARTICULAR APPLICATION IS NOT SPECIFIED, USE GALVANIZED STEEL RIGID METAL CONDUIT. DO NOT USE CONDUIT AND ASSOCIATED FITTINGS FOR APPLICATIONS OTHER THAN AS PERMITTED BY NFPA 70 AND PRODUCT LISTING. REFERENCE THE NEC FOR ADDITIONAL APPLICATION REQUIREMENTS. APPLICATION TYPE OF CONDUIT IN CONCRETE OR MASONRY EMT, IMC, GRC, PVC OUTDOORS (ABOVE GRADE)EMT, IMC, GRC BRANCH CIRCUITS (EXPOSED) EMT, IMC, GRC INTERIOR BRANCH CIRCUITS (CONCEALED BEHIND DRYWALL)MC, EMT, IMC INTERIOR BRANCH CIRCUITS (ABOVE DROPPED CEILINGS)EMT, IMC SUPPLY TO DISTRIBUTION PANELS EMT, IMC, GRC, PVC FINAL CONNECTIONS TO VIBRATING EQUIPMENT (MOTORS, TRANSFORMERS, ETC) SHALL BE MADE WITH FLEXIBLE METAL CONDUIT IN DRY LOCATIONS AND LIQUIDTIGHT FLEXIBLE METAL CONDUIT IN DAMP, WET, OR CORROSIVE LOCATIONS. MAXIMUM LENGTH TO BE 6' UNLESS OTHERWISE INDICATED. INSTALL CONDUIT EXPOSED TO SUNLIGHT ON ROOFTOPS A MINIMUM OF 12" ABOVE ROOF SURFACE. PROVIDE PVC COATED GRC FOR ELBOWS IN PVC CONDUIT RUNS. ALL CONDUITS AND CABLES PASSING THROUGH RATED WALLS, FLOORS OR CEILINGS SHALL BE FIRE STOPPED WITH APPROVED FIRE BARRIER CAULK. INSTALL CAULK PER MANUFACTURE'S INSTRUCTIONS AND MAINTAIN THE RATING OF THE WALL, FLOOR, OR CEILING BEING PENETRATED. DISTRIBUTION EQUIPMENT PROVIDE DISTRIBUTION PANELS, DISCONNECTS, CONTACTORS, ETC. OF VOLTAGE, AMPERAGE, PHASE, AND SHORT-CIRCUIT RATINGS AS INDICATED ON PLANS. TERMINATIONS SHALL BE RATED 75°C MINIMUM CU/AL. FUSES SPECIFIED ARE AS MANUFACTURED BY BUSSMANN. THE SAME CLASS OF FUSE AS MANUFACTURED BY LITTELFUSE AND GOULD-SHAWMUT MAY BE SUBSTITUTED. ENCLOSURES FOR EQUIPMENT AND DEVICES SHALL BE SUITABLE FOR THE INSTALLED LOCATION. PROVIDE DOOR-IN-DOOR HINGED COVER FOR PANELBOARDS. PROVIDE A LISTED BREAKER-TIE OR MULTI-POLE BREAKER FOR EACH MULTIWIRE (SHARED NEUTRAL) BRANCH CIRCUIT. PROVIDE DISTRIBUTION EQUIPMENT AS MANUFACTURED BY AMERICAN MIDWEST POWER, SQUARE D, ELECTRO-MECHANICAL INDUSTRIES, CUTLER-HAMMER, SIEMENS, ERICKSON ELECTRIC, GE OR METRON. THE MOUNTING HEIGHT FOR DISTRIBUTION EQUIPMENT SHALL BE AS INDICATED BELOW, UNLESS OTHERWISE NOTED. PANELBOARDS - 6' AFF MAX TO CENTER OF TOP HANDLE DISCONNECT SWITCHES - 6'-6" AFF MAX TO CENTER OF HANDLE PROVIDE A TYPED PANEL SCHEDULE WITH LOAD DESCRIPTIONS FOR PANELS AFFECTED BY THIS PROJECT. PROVIDE A PHENOLIC LABEL ON EACH NEW OR RENAMED PANEL INDICATING THE PANEL NAME. CLEAN EXPOSED SURFACES AND CHECK TIGHTNESS OF ELECTRICAL CONNECTIONS FOR EQUIPMENT TO BE REUSED. REPLACE DAMAGED CIRCUIT BREAKERS AND PROVIDE CLOSURE PLATES FOR VACANT POSITIONS IN EXISTING PANELS. IDENTIFICATION FOR ELECTRICAL SYSTEMS PROVIDE IDENTIFICATION LABELS OR HANDWRITTEN TEXT USING INDELIBLE MARKER TO IDENTIFY CIRCUITS ENCLOSED IN BOXES. USE IDENTIFICATION LABEL OR ENGRAVED FACEPLATE TO IDENTIFY BRANCH CIRCUITS FEEDING RECEPTACLES AND SWITCHES. PROVIDE IDENTIFICATION ON INSIDE SURFACE OF FACEPLATE FOR RECEPTACLES AND SWITCHES IN PUBLIC AREAS OR IN AREAS AS DIRECTED BY ARCHITECT OR OWNER. USE IDENTIFICATION LABEL TO IDENTIFY RECEPTACLES PROTECTED BY UPSTREAM GFI PROTECTION. LABEL CONDUCTORS AND CABLE WITH POWER SOURCE AND CIRCUIT NUMBER OR OTHER REQUIRED DESIGNATION. USE WRAP-AROUND SELF-ADHESIVE VINYL CLOTH, WRAP-AROUND SELF-ADHESIVE VINYL SELF-LAMINATING, HEAT-SHRINK SLEEVE, PLASTIC SLEEVE, PLASTIC CLIP-ON, OR VINYL SPLIT SLEEVE TYPE MARKERS SUITABLE FOR THE CONDUCTOR OR CABLE TO BE IDENTIFIED. USE FACTORY PRE-PRINTED OR MACHINE-PRINTED TEXT, ALL CAPITALIZED UNLESS OTHERWISE INDICATED. IDENTIFY EACH PIECE OF ELECTRICAL EQUIPMENT WITH AN IDENTIFICATION NAMEPLATE. PROVIDE THE FOLLOWING INFORMATION ON THE NAMEPLATE: PANELBOARDS: AMPERE RATING, VOLTAGE AND PHASE, POWER SOURCE AND CIRCUIT NUMBER, LOADS BEING SERVED (TYPED CIRCUIT DIRECTORY). TRANSFORMERS: kVA RATING, PRIMARY AND SECONDARY VOLTAGE AND PHASE, POWER SOURCE AND CIRCUIT NUMBER. ENCLOSED SWITCHES AND CIRCUIT BREAKERS: AMPERE RATING, VOLTAGE AND PHASE, POWER SOURCE AND CIRCUIT NUMBER, LOAD BEING SERVED. CONDUCTOR INSULATION SHALL BE COLOR CODED AS FOLLOWS: 240/120V, 1Ø: PHASE A - BLACK; PHASE B - RED 480/277V, 3Ø: PHASE A - BROWN; PHASE B - ORANGE; PHASE C - YELLOW IDENTIFY EXISTING ELEMENTS TO REMAIN THAT ARE NOT ALREADY IDENTIFIED. PROVIDE TYPEWRITTEN CIRCUIT DIRECTORY TO IDENTIFY LOADS SERVED FOR PANELBOARDS. UTILIZATION EQUIPMENT VERIFY UTILIZATION EQUIPMENT NAMEPLATE DATA (VOLTAGE, PHASE, FLA, MCA, MOCP, ETC.) PRIOR TO ROUGH-IN. NOTIFY ELECTRICAL ENGINEER IN WRITING OF ANY DISCREPANCIES WITH THESE DRAWINGS IMMEDIATELY AND PRIOR TO COMMENCING ANY FURTHER WORK. ELECTRIC UTILITY COMPANY SUBMIT ELECTRICAL DRAWINGS AND SERVICE APPLICATION TO ELECTRIC UTILITY COMPANY PRIOR TO STARTING ANY WORK. NOTE: ALL SYMBOLS MAY NOT BE USED ON THIS PROJECT LEGEND CIRCUIT RUN IN OR UNDER FLOOR OR IN EARTH POWER DISTRIBUTION CIRCUIT RUN CONCEALED IN WALL OR CEILING CIRCUIT RUN SURFACE MOUNTED MAGNETIC STARTER OR CONTACTOR ELECTRIC METER - UTILITY METER U.O.N. CONTACT - NO - # INDICATES ASSOC. COIL PULLOUT FUSED DISCONNECT SWITCHBOARD OR EQUIPMENT ENCLOSURE NON-FUSED DISCONNECT SWITCH TRANSIENT VOLTAGE SURGE SUPPRESSER FLEXIBLE CONNECTION TO EQUIPMENT HOMERUN - ARROWS INDICATE # OF PHASE COND. PAD MOUNTED TRANSFORMER OVERHEAD SERVICE ENTRANCE CONDUIT STUB - CAP IF UNDERGROUND OR T JORJ/B OR M OR CT M TRANSFORMER JUNCTION BOX TRANSFER SWITCH CONDUIT UP, CONDUIT DOWN FUSED DISCONNECT SWITCH CURRENT TRANSFORMER COMBINATION STARTER GROUNDING ELECTRODE GENERATOR MOTOR NF TVSS CIRCUIT BREAKER SWITCH WITH FUSE OVERLOAD RELAY ELECTRICAL PANEL OR E G SWITCH CONTACT - NC - # INDICATES ASSOC. COIL KIRK KEY INTERLOCK - # INDICATES RELATED KEYSKKI2 COIL - # INDICATES ASSOCIATED CONTACTM2 M2 M2 ~ + - AC POWER SOURCE DC POWER SOURCE SURGE PROTECTIVE DEVICESPD ABBREVIATIONS WP UON UC GFI/GFCI ILT N OR (N) R OR (R) O.C. TL ISC IG G OR GND AC AFI/AFCI FLR CLG E OR (E) CD AFF AIC AFG LET-THROUGH FAULT CURRENT (RMS SYMMETRICAL) GROUND-FAULT CIRCUIT INTERRUPTER AVAILABLE FAULT CURRENT (RMS SYMMETRICAL) ISOLATED GROUND UNDER COUNTER WEATHER PROOF UNLESS OTHERWISE NOTED ON CENTER RELOCATE GROUND TWIST-LOCK NEW AMPERE INTERRUPTING CAPACITY (MINIMUM RATING) ARC-FAULT CIRCUIT INTERRUPTER ABOVE FINISHED FLOOR ABOVE FINISHED GRADE FLOOR MOUNTED CEILING MOUNTED ABOVE COUNTER EXISTING CORD DROP ST SHUNT-TRIP NO/NC NORMALLY OPEN/NORMALLY CLOSED ATS AUTOMATIC TRANSFER SWITCH XP EXPLOSION PROOF TR TAMPER RESISTANT DT DUST TIGHT SCCR SHORT CIRCUIT CURRENT RATING A A PROVIDE CLEAR SPACE EQUAL TO THE WIDTH OF EQUIPMENT OR 30", WHICHEVER IS GREATER. B PROVIDE THE FOLLOWING CLEAR SPACE IN FRONT OF EQUIPMENT: 3' FOR 0-150 L-G VOLTAGE AND 4' FOR 151-600 L-G VOLTAGE. C PROVIDE CLEAR SPACE, FOR THE WIDTH OF THE EQUIPMENT, FROM GRADE, FLOOR OR PLATFORM TO A HEIGHT OF 6-1/2' OR THE HEIGHT OF THE EQUIPMENT, WHICHEVER IS GREATER. D THE SPACE EQUAL TO THE WIDTH AND DEPTH OF THE EQUIPMENT AND EXTENDING FROM THE FLOOR TO A HEIGHT OF 6' ABOVE THE EQUIPMENT OR TO THE STRUCTURAL CEILING, WHICHEVER IS LOWER, SHALL BE DEDICATED TO THE ELECTRICAL INSTALLATION - NO PIPING, DUCTS, LEAK PROTECTION APPARATUS, OR OTHER EQUIPMENT FOREIGN TO THE ELECTRICAL INSTALLATION SHALL BE LOCATED IN THIS ZONE. SUSPENDED CEILINGS WITH REMOVABLE PANELS SHALL BE PERMITTED WITHIN THE 6' ZONE. SPRINKLER PROTECTION SHALL BE PERMITTED FOR THE DEDICATED SPACE WHERE THE PIPING COMPLIES WITH THIS SECTION. A DROPPED, SUSPENDED, OR SIMILAR CEILING THAT DOES NOT ADD STRENGTH TO THE BUILDING STRUCTURE SHALL NOT BE CONSIDERED A STRUCTURAL CEILING. E THE AREA ABOVE THE DEDICATED SPACE SHALL BE PERMITTED TO CONTAIN FOREIGN SYSTEMS, PROVIDED PROTECTION IS INSTALLED TO AVOID DAMAGE TO THE ELECTRICAL EQUIPMENT FROM CONDENSATION, LEAKS, OR BREAKS IN SUCH FOREIGN SYSTEMS. B C D D E E CLEAR SPACE/WORKING SPACE ABOUT ELECTRICAL EQUIPMENT THE FINAL LOCATION OF EQUIPMENT SHALL BE COORDINATED IN THE FIELD, PRIOR TO ROUGH-IN, TO MEET APPLICABLE LOCATION, HEIGHT AND CLEARANCE REQUIREMENTS. THE ELECTRICAL CONTRACTOR SHALL STOP WORK IMMEDIATELY, AND ADVISE OTHERS TO STOP WORK IF THERE IS A CONFLICT WITH THE ELECTRICAL CLEARANCE AND WORK SPACE REQUIREMENTS PER THE ABOVE INFORMATION AND THE NEC. D FRONT VIEW OF EQUIPMENT SIDE VIEW OF EQUIPMEN 11 OF 14 ELECTRICAL SPECIFICATIONS & LEGEND Kazin & Associates, Inc. Village Square at Lone Tree 9364 Teddy Lane, Ste #101 Lone Tree, CO 80124 © 2017 Phone: 720-489-1609 Fax: 720-489-1611 Project #: 17198 Consulting Electrical Engineers Est. 1984 E-1 P R O F E S S I O NAL EN G I N E E R NIZAKNAYR B 12208 S T A TE O IF E D RESTIGER D O HA7/11/17 D D D D D D D D D D D D D D D D D CBCB CB CB CB ET CA B D W WV WV H Y D HY D WV D T PANEL "LVZ" 15kVA TRANSFORMER30A2P (E) 3000A "MDP" SERVICE LOAD CALCULATION LOAD DESCRIPTION LOAD EXISTING LOAD PER EXISTING ELECTRICAL DRAWINGS 1,305.9kVA PANEL LVZ 12.0kVA TOTAL LOAD 1,317.9kVA TOTAL AMPERAGE @ 1,585A VOLTAGE 480 PHASE 3 FAULT CURRENT CALCULATIONS (TRANSFORMER SECONDARY) LOCATION DESCRIPTION TRANSFORMER kVA %Z SECONDARY VOLTAGE PHASE ISC AT SECONDARY @ SECONDARY OF 15KVA XFMR 15 2.3 120 1.00 5,435 @ SECONDARY OF 15KVA XFMR 15 2.3 240 1.00 2,717 2 PARTIAL ONE-LINE DIAGRAM NOT TO SCALE NOTES: 1.EQUIPMENT, WIRING, AND DEVICES SHOWN LIGHT ARE EXISTING AND SHOWN DARK ARE NEW UNLESS OTHERWISE NOTED. 2.CONDUCTORS ARE COPPER UNLESS OTHERWISE NOTED. 3.NEW WIRING SHALL BE THHN/THWN-2 INSULATED COPPER UNLESS OTHERWISE NOTED. T M 30 0 0 A 3 P / S T / G F 16 0 0 A 3 P / S T / G F KKI 1 N G 3000A MSB 480Y/277V, 3Ø, 4W 65,000AIC 30 A 2 P UTILITY-COMPANY PAD-MOUNTED TRANSFORMER 480Y/277V, 3Ø, 4W SECONDARY PANEL LVZ 60 A 2 P 15kVA, 1Ø 480-240/120V N G (3 #4, 1 #8G)1 1/4"C (60A)(2 #10, 1#10G)1/2"C (30A) #6 TO BUILDING STEEL 3 0 A 2 P 3 0 F R S - R WP WP WP M 30A, 480V, 1-PHASE kWH/DEMAND CHECK METER (2 #6, 1 #6G)2"C (30A) ISC = 32,947A PER EXISTING ELECTRICAL DRAWINGS 8[4-500kcmil CU] OR EQUAL (3000A) 3000A MDP 480Y/277V, 3Ø, 4W 65,000AIC 8[4-500kcmil CU, 1-500kcmil CU G] OR EQUAL (3000A) ISC = 48,472A PER EXISTING ELECTRICAL DRAWIN 12 OF 14 ONE-LINE DIAGRAM, PANEL SCHEDULE & ELECTRICAL PLAN 1 PARTIAL ELECTRICAL PLAN NOT TO SCALE NORTH Kazin & Associates, Inc. Village Square at Lone Tree 9364 Teddy Lane, Ste #101 Lone Tree, CO 80124 © 2017 Phone: 720-489-1609 Fax: 720-489-1611 Project #: 17198 Consulting Electrical Engineers Est. 1984 E-2 P R O F E S S I O NAL EN G I N E E R NIZAKNAYR B 12208 S T A TE O IF E D RESTIGER D O HA7/11/17 OF 14 1 G-1 ANTENNA/RRH GROUNDING DETAIL N.T.S. Know what's below. Call before you dig. GROUNDING PLAN & NOTES G-1 13 GROUNDING NOTES: 2 G-1 CABINET/TRANSFORMER GROUNDING DETAIL N.T.S. 07/19/17 OF 14 Know what's below. Call before you dig. GROUNDING DETAILS G-2 14 1 G-2 TYPICAL CABLE GROUNDING DETAIL N.T.S. 5 G-2 GROUND BAR DETAIL N.T.S. 3 G-2 TYPICAL CADWELD TYPE CONNECTIONS N.T.S. 2 G-2 WEATHERPROOFING DETAIL N.T.S. 4 G-2 ANTENNA GROUND BAR CONNECTIONS N.T.S.07/19/17